Search NASA⌕ Search

SEARCH · Search NASA

Results for “efficient envelope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Searching for Rapid Orbital Decay of WASP-18b

The WASP-18 system, with its massive and extremely close-in planet, WASP-18b ( M{sub p} = 10.3 M{sub J}, a = 0.02 au, P = 22.6 hr), is one of the best-known exoplanet laboratories to directly measure Q ′, the modified tidal quality factor and proxy for efficiency of tidal dissipation, of the host star. Previous analysis predicted a rapid orbital decay of the planet toward its host star that should be measurable on the timescale of a few years, if the star is as dissipative as is inferred from the circularization of close-in solar-type binary stars. We have compiled published transit and secondary eclipse timing (as observed by WASP, TRAPPIST, and Spitzer ) with more recent unpublished light curves (as observed by TRAPPIST and Hubble Space Telescope ) with coverage spanning nine years. We find no signature of a rapid decay. We conclude that the absence of rapid orbital decay most likely derives from Q ′ being larger than was inferred from solar-type stars and find that Q ′ ≥ 1 × 10{sup 6}, at 95% confidence; this supports previous work suggesting that F stars, with their convective cores and thin convective envelopes, are significantly less tidally dissipative than solar-type stars, with radiative cores and large convective envelopes.

79 ASTRONOMY AND ASTROPHYSICS↗

DYNAMIC THERMALLY-DISCONNECTED BUILDING ENVELOPES A NEW PARADIGM FOR WALLS AND ROOFS IN LOW ENERGY BUILDINGS

This paper describes numerical and experimental analysis of a novel design concept. Traditionally the thermal design of building envelope assemblies is based on a static energy flow. However, building envelopes are subject to varying environmental conditions. This mismatch between the steady-state principles used in the design of roofs and walls and their dynamic operation results in relatively low thermal efficiency. Design work in support of the development of zero energy houses showed that conventional insulations may not be the most cost effective energy solution. Testing conducted on several strategies to thermally-disconnect wall and roof components showed 70% to 90% reductions in peak hour loads as compared to conventional building practice.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Achieving Very High Efficiency and Net Zero Energy in an Existing Home in a Hot-Humid Climate: Long-Term Utility and Monitoring Data (Revised)

This study summarizes the first six months of detailed data collected on a single family home that experienced a series of retrofits targeting reductions in energy use. The project was designed to develop data on how envelope modifications and renewable measures can result in considerable energy reductions and potentially net zero energy for an existing home. Originally published in February2012, this revised version of the report contains further research conducted on the Parker residence. Key updates include one full year of additional data, an analysis of cooling performance of the mini-split heat pump, an evaluation of room-to-room temperature distribution, and an evaluation of plug-in automobile charging performance, electricity consumption, and load shape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Achieving Very High Efficiency and Net Zero Energy in an Existing Home in a Hot-Humid Climate: Long-Term Utility and Monitoring Data

This study summarizes the first six months of detailed data collected on a single family home that experienced a series of retrofits targeting reductions in energy use. The project was designed to develop data on how envelope modifications and renewable measures can result in considerable energy reductions and potentially net zero energy for an existing home. Originally published in February 2012, this revised version of the report contains further research conducted on the Parker residence. Key updates include one full year of additional data, an analysis of cooling performance of the mini-split heat pump, an evaluation of room-to-room temperature distribution, and an evaluation of plug-in automobile charging performance, electricity consumption, and load shape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy efficient soundproofing window retrofits

Described herein are window retrofits including a monolithic silica aerogel slab having (i) an average haze value of <5% as calculated in accordance with ASTM standard D1003-13 and (ii) a U-factor of <0.5 BTU/sf/hr/° F., and a transparent polymer envelope sealed at an internal pressure of ≤1 atmosphere, wherein the monolithic silica aerogel slab is encapsulated in the transparent polymer envelope. The monolithic aerogel slab can have a transmittance >94% at 8 mm thickness. The window retrofit can be bonded to a glass sheet.

Wang, Evelyn N.↗

Experimental studies of a high-gradient X-band welded hard-copper split accelerating structure

We report on recent research on high-gradient radio frequency (RF) accelerating structures indicates that the use of hard copper alloys provides improvement in high gradient performance over annealed copper. Such structures are made by bonding individually manufactured parts. However, there are no well-established bonding techniques that preserve the hardness, surface finish and cleanliness required for high gradient operation. To preserve the copper hardness, RadiaBeam has developed a novel high-gradient split accelerating structure, based on electron beam welding joining technique. This technique provides efficient bonding with strong, clean welds and minimal thermal loading, while maintaining a clean inner RF environment. Our RF design and fabrication methodology limits the small heat affected zone to the outer cavity envelop, with virtually no distortions or thermal loading of critical RF surfaces. It also incorporates provisions to precisely control the gap despite conventional issues with weld joint shrinkage. To date we have manufactured and validated an RF accelerating structure joined by electron-beam welding that incorporates a novel open split design to significantly reduce the assembly complexity and cost. In this paper, we will present the electromagnetic design of this structure, discuss bonding, and present the results of high-power tests, where the accelerating gradients of 140 MV m -1 with surface peak fields of 400 MV m -1 were achieved for flat-top pulse length of 600 ns with an RF breakdown rate of 10 -4 1/(pulsecm).

43 PARTICLE ACCELERATORS↗

Equitable Electrification Analysis for Existing Buildings in Richmond, CA

Over a 12-month period beginning in July 2022, NREL coordinated with a coalition of staff from the City of Richmond and local community organizations to develop and conduct a city-wide building energy use analysis and develop and assess the impacts of various approaches to electrifying and improving energy efficiency of all existing residential and commercial buildings within the city limits. Building on data available through NREL's ResStock™ and ComStock™ analysis tools, the authors looked at potential modeled impacts of building envelope and electrification upgrades on five indicators identified by the community coalition: building energy consumption, greenhouse gas (GHG) emissions, utility bill charges and cost-effectiveness, employment impacts, and health and safety impacts. This report summarizes the findings of that research and analysis.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Online Airtightness Calculator for the US, Canada and China

The contribution of air leakage to heating and cooling loads has been increasing as the thermal resistance of building envelopes continues to improve. Easy-to-access data are needed to convince building owners and contractors that enhancing the airtightness of buildings is the next logical step to achieve a high-performance building envelope. To this end, Oak Ridge National Laboratory, the National Institute of Standards and Technology, the Air Barrier Association of America, and the US-China Clean Energy Research Center for Building Energy Efficiency Consortium partnered to develop an online calculator that estimates the potential energy savings in major US, Canadian, and Chinese cities due to improvements in airtightness. This tool will have user-friendly graphical interface that uses a database of CONTAM-EnergyPlus pre-run simulation results, and will be available to the public at no cost. Baseline leakage rates are either user-specified or the user selects them from the supplied typical leakage rates. Users will enter the expected airtightness after the proper installation of an air barrier system. Energy costs are estimated based on the building location and inputs from users. This paper provides an overview of the methodology that is followed in this calculator, as well as results from an example. The successful deployment of this calculator could influence construction practices so that greenhouse gas emissions from the US, Canada, and China are significantly curtailed.

air leakage↗

Modeling and Validation of a Residential Multi-Functional Variable Refrigerant Flow Heat Pump System with Heat Recovery

To bridge the existing gap in modeling the variable refrigerant flow heat pump systems with heat recovery (VRFHR), we developed a suite of dynamic VRFHR system models in Modelica. These models are specifically tailored for residential multi-functional VRFHR (MF-VRFHR) applications, including space conditioning and domestic hot water (DHW) heating, utilizing both the TIL library for HVAC equipment and the Buildings library for thermal load calculations. The development comprises essential component models, including the newly developed heat recovery unit (HRU), along with system models that integrate the heat pump system and building envelope. These system models accommodate various operational modes such as heating-only, cooling-only, and heating-recovery (including heating-dominant and cooling-dominant) modes. Furthermore, we propose an efficient optimization-based model calibration method that identifies critical model parameters while utilizing a small amount of data obtained from either real systems or manufacturer's specifications. We demonstrate the effectiveness of these models and the proposed calibration method for a MF-VRFHR system installed in Richland, WA. The developed models are calibrated and validated using data collected under different operational modes during both heating and cooling seasons. The results show that the models capture the system dynamics and achieve high accuracy, with the coefficient of the variation of the root-mean-square-error less than 15% for variables such as outdoor unit power consumption, compressor speed, space temperature and DHW temperature. The validated models serve as a reliable representation of the MF-VRFHR system, facilitating the development and validation of optimized controls needed to realize the full benefits of integrated heat pump systems. Future research will utilize these models to develop advanced controls and optimize system performance for improved energy efficiency and demand flexibility.

Modeling, Variable refrigerant flow (VRF) systems,↗

Side-by-Side Field Evaluation of Highly Insulating Windows in the PNNL Lab Homes

To examine the energy, air leakage, and thermal performance of highly insulating windows, a field evaluation was undertaken in a matched pair of all-electric, factory-built “Lab Homes” located on the Pacific Northwest National Laboratory (PNNL) campus in Richland, Washington. The “baseline” Lab Home B was retrofitted with “standard” double-pane clear aluminum-frame slider windows and patio doors, while the “experimental” Lab Home A was retrofitted with Jeld-Wen® triple-pane vinyl-frame slider windows and patio doors with a U-factor of 0.2 and solar heat gain coefficient of 0.19. To assess the window, the building shell air leakage, energy use, and interior temperatures of each home were compared during the 2012 winter heating and summer cooling seasons. The measured energy savings in Lab Home B averaged 5,821 watt-hours per day (Wh/day) during the heating season and 6,518 Wh/day during the cooling season. The overall whole-house energy savings of Lab Home B compared to Lab Home A are 11.6% ± 1.53% for the heating season and 18.4 ± 2.06% for the cooling season for identical occupancy conditions with no window coverings deployed. Extrapolating these energy savings numbers based on typical average heating degree days and cooling degree days per year yields an estimated annual energy savings of 12.2%, or 1,784 kWh/yr. The data suggest that highly insulating windows are an effective energy-saving measure that should be considered for high-performance new homes and in existing retrofits. However, the cost effectiveness of the measure, as determined by the simple payback period, suggests that highly insulating window costs continue to make windows difficult to justify on a cost basis alone. Additional reductions in costs via improvements in manufacturing and/or market penetration that continue to drive down costs will make highly insulating windows much more viable as a cost-effective energy efficiency measure. This study also illustrates that highly insulating windows have important impacts on peak load, occupant comfort, and condensation potential, which are not captured in the energy savings calculation. More consistent and uniform interior temperature distributions suggest that highly insulated windows, as part of a high performance building envelope, may enable more centralized duct design and downsized HVAC systems. Shorter, more centralized duct systems and smaller HVAC systems to yield additional cost savings, making highly insulating windows more cost effective as part of a package of new construction or retrofit measures which achieve significant reductions in home energy use.

PNNL Lab Homes↗

THE EFFECT OF THE {sup 14}N(p, {gamma}){sup 15}O REACTION ON THE BLUE LOOPS IN INTERMEDIATE-MASS STARS

We present stellar evolutionary sequences of stars in the mass range 5-12 M{sub Sun }, having solar-like initial composition. The stellar models are obtained using updated input physics, including recent rates of thermonuclear reactions. We investigate the effects of a modification of the {sup 14}N(p, {gamma}){sup 15}O reaction rate, as suggested by recent evaluations, on the formation and extension of the blue loops encountered during the evolution of the stars in the above mass range. We find that a reduced {sup 14}N(p, {gamma}){sup 15}O rate, as described in the text, has a striking impact on the physical conditions of burning and mixing during shell hydrogen burning when the blue loops are formed. In particular, we find that the efficiency of shell hydrogen burning is crucial for the formation of an extended blue loop. We show that a significantly reduced {sup 14}N(p, {gamma}){sup 15}O rate affects severely the extension of the blue loops and the time spent by the star in the blue part of the Hertzsprung-Russell diagram in the mass range 5-7 M{sub Sun} if the treatment of convection is based on the Schwarzschild criterion only. In this case, envelope overshooting helps to restore well-extended blue loops as supported by the observations of the Cepheid stars. If core overshooting is included during the core hydrogen and core helium burning phases, the loop formation and its properties depend on how this overshooting is treated for a given stellar mass range, as well as on its efficiency.

79 ASTRONOMY AND ASTROPHYSICS↗

WBG-Enabled Current-Source Inverters for Integrated PM Motor Drives

This project takes advantage of the special capabilities of wide-bandgap (WBG) power semiconductor devices to develop innovative power electronics in the form of new current-source inverters (CSIs) that offer promising advantages over the dominant voltage-source inverter (VSI) topology. These CSIs, in turn, are extremely well-suited for integration into the housings of permanent magnet synchronous machines (PMSMs) to form integrated motor drives (IMDs). These new IMDs offer great promise for achieving major energy savings in a wide variety of applications that benefit from adjustable-speed control, including air conditioners, laundry appliances, industrial pumps/compressors, electric vehicles, and aerospace drives. WBG devices play a critical enabling role in these new IMDs because of their transformative features including much higher switching frequencies, lower losses, and compatibility with high operating temperatures. When incorporated into new CSI-based IMDs with PM machines, these WBG switches open the door to achieving major increases in power density, drive system efficiency, and fault tolerance, as well as substantial reductions in electromagnetic interference (EMI), manufacturing cost, and temperature-induced failures. The higher operating temperature capability of WBG devices compared to conventional silicon power devices is very appealing in IMD applications because the power electronics is mounted in close proximity to the motors which typically operate at temperatures well above the maximum limits of today’s silicon-based power electronics. This project has succeeded in designing, building, and testing multiple prototype versions of this CSI-IMD that have overcome many technical challenges in order to demonstrate the impressive performance improvements that can be achieved by the WBG-enabled CSI-IMD. The preliminary demo and bench-top versions of the current-source inverter developed during the first two years of the project were critical to laying the technical foundations for the 3 kW prototype CSI-IMD unit that was successfully built and tested during the third year. This prototype CSI-IMD unit was designed to fit within the housing envelope of the original permanent magnet (PM) synchronous machine in order to meet the demanding power density requirements that were set at the beginning of the project. All of the remaining performance objectives set for the prototype CSI-IMD unit including efficiency and electromagnetic interference (EMI) were also met. The last 18 months of the project were devoted to developing further enhancements of the WBG-enabled CSI-IMD technology that better prepare it for commercial production. More specifically, an upgraded version of the prototype CSI-IMD unit was developed that moved the power electronics into the same machine housing chamber as the motor, substantially raising the thermal demands on the power electronics. Tests with five different combinations of motor enclosure types and air cooling configurations were evaluated. Importantly, this work confirmed that the power electronics can deliver its full rated power and still operate well within its maximum temperature limits even for worst-case conditions when the housing is “totally-enclosed” without any openings for air to enter or exit the enclosure, and no blower/fan is provided to blow air over the outside surface of the enclosure. Reaching the full performance and energy-savings potential of this disruptive CSI-IMD motor drive technology is highly consistent with ARPA-E’s stated mission to “enhance the economic and energy security of the United States” while also supporting its commitment to “ensure that the U.S. maintains a technological lead in developing and deploying advanced energy technologies”. Follow-on projects are under way to explore the scalability of WBG-enabled CSI-IMD technology to 100 kW (peak) electric vehicle traction drives and fault-tolerant modular motor drives for future electrified aircraft propulsion applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NEUTRINO EMISSION FROM COOPER PAIRS AND MINIMAL COOLING OF NEUTRON STARS

The minimal cooling paradigm for neutron star cooling assumes that enhanced cooling due to neutrino emission from any direct Urca process, due either to nucleons or to exotica such as hyperons, Bose condensates, or deconfined quarks, does not occur. Previous studies showed that the observed temperatures of young, cooling, isolated neutron stars with ages between 10{sup 2} and 10{sup 5} yr, with the possible exception of the pulsar in the supernova remnant CTA 1, are consistent with predictions of the minimal cooling paradigm as long as the neutron {sup 3} P{sub 2} pairing gap present in the stellar core is of moderate size. Recently, it has been found that Cooper-pair neutrino emission from the vector channel is suppressed by a large factor, of the order of 10{sup -3}, compared to the original estimates that violated vector current conservation. We show that Cooper-pair neutrino emission remains, nevertheless, an efficient cooling mechanism through the axial channel. As a result, the elimination of neutrino emission from Cooper-paired nucleons through the vector channel has only minor effects on the long-term cooling of neutron stars within the minimal cooling paradigm. We further quantify precisely the effect of the size of the neutron {sup 3} P{sub 2} gap and demonstrate that consistency between observations and the minimal cooling paradigm requires that the critical temperature T{sub c} for this gap covers a range of values between T {sup min}{sub c} approx< 0.2 x 10{sup 9} up to T {sup max}{sub c} approx> 0.5 x 10{sup 9} in the core of the star. This range of values guarantees that the Cooper-pair neutrino emission is operating efficiently in stars with ages between 10{sup 3} to 10{sup 5} yr, leading to the coldest predicted temperatures for young neutron stars. In addition, it is required that young neutron stars have heterogeneous envelope compositions: some must have light-element compositions and others must have heavy-element compositions. Unless these two conditions are fulfilled, about half of the observed young cooling neutron stars are inconsistent with the minimal cooling paradigm and provide evidence for the existence of enhanced cooling.

79 ASTRONOMY AND ASTROPHYSICS↗

Online Learning for Commercial Buildings

There has been an increased interest in designing optimization based techniques for the control of building heating, ventilation, and air-conditioning (HVAC) systems for either improving the energy efficiency of buildings or providing ancillary services to the electric grid. The performance of such prediction-based control techniques heavily rely on the model of a building’s thermal dynamics. However, the development of high fidelity building thermal dynamic models is challenging given the presence of large uncertainties that affect thermal loads in buildings such as building envelope performance, thermal mass, internal heat gains as well as occupants' behavior. In this paper, we propose a method to identify both a resistive-capacitive parametric model, and non -parametric load uncertainties using measured input-output data. The parametric model is obtained using semi-parametric regression, whereas the non-parametric part is based on Random Forest, where regression trees are used to derive the dependency of non-parametric terms on both building operation parameters and ambient temperature. The effectiveness of the method is evaluated using experimental data collected from an office building at the Pacific Northwest National Laboratory (PNNL) campus. The proposed methodology was observed to provide improved accuracy over appropriate baseline strategies, when predicting indoor air temperatures.

Dong, Jin↗

ALMA Cycle 1 observations of the HH 46/47 molecular outflow: structure, entrainment, and core impact

We present Atacama Large Millimeter/sub-millimeter Array Cycle 1 observations of the HH 46/47 molecular outflow using combined 12 m array and Atacama Compact Array observations. The improved angular resolution and sensitivity of our multi-line maps reveal structures that help us study the entrainment process in much more detail and allow us to obtain more precise estimates of outflow properties than in previous observations. We use {sup 13}CO (1–0) and C{sup 18}O (1–0) emission to correct for the {sup 12}CO (1–0) optical depth to accurately estimate the outflow mass, momentum, and kinetic energy. This correction increases the estimates of the mass, momentum, and kinetic energy by factors of about 9, 5, and 2, respectively, with respect to estimates assuming optically thin emission. The new {sup 13}CO and C{sup 18}O data also allow us to trace denser and slower outflow material than that traced by the {sup 12}CO maps, and they reveal an outflow cavity wall at very low velocities (as low as 0.2 km s{sup −1} with respect to the core’s central velocity). Adding the slower material traced only by {sup 13}CO and C{sup 18}O, there is another factor of three increase in the mass estimate and 50% increase in the momentum estimate. The estimated outflow properties indicate that the outflow is capable of dispersing the parent core within the typical lifetime of the embedded phase of a low-mass protostar and that it is responsible for a core-to-star efficiency of 1/4 to 1/3. We find that the outflow cavity wall is composed of multiple shells associated with a series of jet bow-shock events. Within about 3000 au of the protostar the {sup 13}CO and C{sup 18}O emission trace a circumstellar envelope with both rotation and infall motions, which we compare with a simple analytic model. The CS (2–1) emission reveals tentative evidence of a slowly moving rotating outflow, which we suggest is entrained not only poloidally but also toroidally by a disk wind that is launched from relatively large radii from the source.

79 ASTRONOMY AND ASTROPHYSICS↗

An Energy Calculator for Simple Commercial Buildings

According to the EIA, simple commercial buildings account for 97% of total commercial building stock. However, most simple commercial buildings for example small- to mid-sized offices, retail, schools and warehouses do not benefit from the data-driven decision-making capabilities of whole-building energy modeling. The high cost of custom modeling limits the use of energy modeling of simple buildings for new construction or retrofit measures. Lack of tools providing helpful information on interactive savings estimates creates difficulties in meeting aggressive decarbonization and energy efficiency goals for simple building designers and utility program managers. This paper reviews a beta phase Simple Building Calculator with the ability to generate relatively accurate and interactive modeling results based on a limited but robust set of inputs. It can evaluate whole-building or single measure savings in new or existing buildings, compare measure package choices, or provide simplified performance modeling for energy codes and utility incentives. The tool combines physical (annual whole building prototype simulation) and statistical modeling techniques to predict annual energy performance. It supports a variety of building characteristics for envelope, HVAC, and lighting with parameters ranging from vintage to max tech configurations, as well as support for single-zone and simple multi-zone HVAC systems. The Simple Building Calculator was designed to provide immediate feedback for otherwise computationally intensive tasks like measure comparison, development of multiple measure package combinations, or verification that measures meet efficiency targets—all with the goal of providing a tool for quick annual energy simulation of simple commercial buildings.

Hart, Reid↗

Graphene reinforced UHMWPE fibers

Thermoplastic polymers are increasingly used in electric vehicles, hydrogen fuel cell vehicles, and other decarbonization applications due to their lightweight and formability. Higher-strength polymers are needed to supplant metals in the vehicle structure, thereby reducing mass and improving efficiency. Ultra-high molecular weight polyethylene (UHMWPE) fibers possess one of the highest strength-to-weight ratios of technical polymers, and further improvement via reinforcement by nanofillers, such as graphene, will expand their performance envelope. Here, in this work, UHMWPE/graphene nanocomposite fibers were gel spun and characterized for their morphological, microstructural, thermal, and mechanical properties. The addition of a low fraction of graphene improved the tensile strength of the fibers by 25% and tensile modulus by 32%. Differential scanning calorimetry showed an increase in melting temperature and degree of crystallinity, which indicates improved coordination of the molecular chains induced by the addition of graphene. The reinforcement also affected the cross-sectional shape of the fibers; the aspect ratio of the fibers’ elliptical shape declined with increasing graphene content showing the skeletal effect of the graphene nanofillers in the polymer matrix. The reinforcing effect of graphene declined above a threshold concentration, and theoretical modeling was applied to demonstrate that increased agglomerates led to reduced properties. This work demonstrates a simple, effective method to produce graphene-reinforced UHMWPE fibers and lays a foundation for understanding the potential for leveraging graphene to form ultra-high-performance nanocomposite fibers for myriad engineering applications.

36 MATERIALS SCIENCE↗