Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Sensitive Ion Pump Current Monitoring Using an In-House Built Ion Pump Power Supply

Ion pumps are common vacuum pumps on DC high voltage photoguns and baked-accelerator beamlines. Commercial ion pump power supplies provide a measure of the electrical current drawn by the pump, but typically have resolution to only {approx}0.1 uA, which corresponds to pressure {approx}10{sup -9} Torr, a value considerably higher than the minimum pressure required by photoguns and nearby beamline. This submission describes a very sensitive in-house-built ion pump power supply with current monitoring capability good to less than 1 nA, and corresponding pressure in the low-minus;10{sup -11} Torr range. Besides providing 'free' pressure monitoring on a scale equivalent to the best available commercial pressure gauges, the ion pump power supply also serves as a sensitive diagnostic for detecting field emission from the photogun cathode electrode and bad electron beam orbits that could diminish photogun operating lifetime. Since its inception, this ion pump power supply has become an invaluable tool for operating the CEBAF polarized electron source. It is also a very useful low-cost diagnostic for ultrahigh vacuum studies in the laboratory.

43 PARTICLE ACCELERATORS↗

Direct synthesis of Cu{sub 2}O-RGO nanocomposite on Cu foil by thermal evaporation method and its field emission study

In this work, a facile one step thermal evaporation method for deposition of Cu{sub 2}O nanoparticles on RGO sheets to form Cu{sub 2}O-RGO nanocomposite is discussed. To the best of our knowledge, this is the first report on Cu{sub 2}O-RGO nanocomposite, directly grown on Cu foil by a simple thermal evaporation route. The as –prepared nanocomposite exhibits well dispersed Cu{sub 2}O nanoparticles distributed all over the graphene sheet. Field emission properties of the nanocomposite were investigated at a base pressure of 1*10{sup −8} torr. The turn on field, required to draw emission current density of 0.1µA/cm2, was found to be 3.8V/µm with a maximum emission current density of 80 µA/cm2 at an applied field of 6.8 V/µm. Moreover, the nanocomposite shows fairly good emission stability without significant degradation of emission current. The FE results seem to be encouraging, indicative of potential candidature of the Cu{sub 2}O-RGO nanocomposite emitter as an electron source for practical applications in vacuum nanoelectronic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of diagnostic and manipulation systems for space-charge dominated electron beams and confined electron plasmas in ELTRAP

Modifications have been implemented in the Penning-Malmberg device ELTRAP aimed at performing studies on the dynamics of space-charge dominated nanosecond electron bunches traveling along the magnetic field. In particular, a Thomson backscattering apparatus has been developed where an infrared (IR) laser pulse collides with the bunched electron beam. The frequency-shifted backscattered radiation, acquired by means of a photomultiplier (PMT), can be exploited to evaluate information on energy, energy spread and density of the bunch. The achievable sensitivity of the diagnostics has been estimated, and valuable information on the main parameters affecting the signal-to-noise (S/N) ratio has been obtained [B. Paroli, F. Cavaliere, M. Cavenago, F. De Luca, M. Ikram, G. Maero, C. Marini, R. Pozzoli, and M. Rome, JINST 7, P01008 (2012)]. A series of upgrades are under way, aimed at increasing the S/N ratio through the use of a new laser for the electron source, the insertion of a stray light shield, and the optimization of the detection electronics. Moreover, electromagnetic simulations relevant to the design and implementation of a microwave heating system are presented. The generation of an electron plasma in ELTRAP by means of a low-power radio frequency (RF) drive in the MHz range applied on one of the trap electrodes and under ultra-high vacuum (UHV) conditions has previously been demonstrated [B. Paroli, F. De Luca, G. Maero, F. Pozzoli, and M. Rome, Plasma Sources Sci. Technol. 19, 045013 (2010)]. The new heating system will allow the extension of the RF studies to the GHz range and in particular the production of a more energetic electron plasma via cyclotron resonant excitation.

43 PARTICLE ACCELERATORS↗

Improved robustness of sequentially deposited potassium cesium antimonide photocathodes achieved by increasing the potassium content towards theoretical stoichiometry

Alkali antimonide semiconductor photocathodes are promising candidates for high-brightness electron sources for advanced accelerators, including free-electron lasers (FEL), due to their high quantum efficiency (QE), low emittance, and high temporal resolution. Two challenges with these photocathodes are (1) the lack of a universal deposition recipe to achieve crystal stoichiometries and (2) their high susceptibility to vacuum contamination, which restricts their operation pressure to ultrahigh vacuums and leads to a short lifetime and low extraction charge. To resolve these issues, it is essential to understand the elemental compositions of deposited photocathodes and correlate them to robustness. Here, we report depth profiles for potassium cesium antimonide photocathodes, which were investigated using synchrotron radiation x-ray photoelectron spectroscopy, and the robustness of those photocathodes. We prepared two types of photocathodes with different potassium contents via sequential thermal evaporation. Depth profiles revealed that the photocathodes with a potassium deficit had excess cesium at the surface, while the ratio of potassium and cesium to antimony decreased rapidly within the film. In contrast, the photocathodes with sufficient potassium had close to the theoretical stoichiometry of K 2 CsSb at the surface and maintained that stoichiometry for over half the entire film thickness. Both photocathode types had a similar maximum QE at 532 nm; however, exposure to oxygen revealed that the photocathode with a crystalline stoichiometry of K 2 CsSb maintained QE at one order of magnitude higher pressure compared to its potassium-deficit counterpart. These results highlight the importance of synthesizing potassium cesium antimonide photocathodes with sufficient potassium to achieve the theoretical crystalline stoichiometry for both high QE and improved robustness.

47 OTHER INSTRUMENTATION↗

Note: Characteristic beam parameter for the line electron gun

We have optimized the beam parameters of line source electron gun using Stanford Linear Accelerator Centre electron beam trajectory program (EGUN), utilizing electrostatic focusing only. We measured minimum beam diameter as 0.5 mm that corresponds to power density of 68.9 kW/cm{sup 2} at 13.5 mm in the post-anode region which is more than two-fold (33 kW/cm{sup 2}), of the previously reported results. The gun was operated for the validation of the theoretical results and found in good agreement. The gun is now without any magnetic and electrostatic focusing thus much simpler and more powerful.

43 PARTICLE ACCELERATORS↗

Perspectives on Designer Photocathodes for X-ray Free-Electron Lasers: Influencing Emission Properties with Heterostructures and Nanoengineered Electronic States

Here, the development of photoemission electron sources to specifically address the competing andnincreasingly stringent requirements of advanced light sources such as X-ray Free Electron Lasers (XFELs) motivates a comprehensive material-centric approach that integrates predictive compu- tational physics models, advanced nano-synthesis methods, and sophisticated surface science char- acterization with in situ correlated study of photoemission performance and properties. Related efforts in material science are adopting various forms of nanostructure (such as compositionally graded stoichiometry in heterostructured architectures, and quantum features) allowing for tailored electronic structure to control and enhance opto-electronic properties. These methods influence the mechanisms of photoemission (absorption, transport, and emission) but have not, as yet, been systematically considered for use in photocathode applications. Recent results and near-term op- portunities are described to exploit controlled functionality of nanomaterials for photoemission. An overview of the requirements and status is provided.

47 OTHER INSTRUMENTATION↗

The effect of the H{sub 2} density on the electron energy distribution in H{sup −} ion sources

The electron energy distribution in H{sup −} ion sources is studied. By three-dimensional Monte Carlo simulations (3D-MCC) and cross sections of collisions, the crucial collisions in the JAEA 10A are chosen to develop theoretical models for the low electron temperature and the high electron temperature, respectively. The effects of the H{sub 2} density on the low electron temperature and the high electron temperature in H{sup −} ion sources are predicted with analytic expressions and verified by 3D-MCC. The results show that both the low and high electron temperatures become lower while n{sub H2} increases.

43 PARTICLE ACCELERATORS↗

Time resolved electron microscopy for in situ experiments

Transmission electron microscopy has functioned for decades as a platform for in situ observation of materials and processes with high spatial resolution. Yet, the dynamics often remain elusive, as they unfold too fast to discern at these small spatial scales under traditional imaging conditions. Simply shortening the exposure time in hopes of capturing the action has limitations, as the number of electrons will eventually be reduced to the point where noise overtakes the signal in the image. Pulsed electron sources with high instantaneous current have successfully shortened exposure times (thus increasing the temporal resolution) by about six orders of magnitude over conventional sources while providing the necessary signal-to-noise ratio for dynamic imaging. We describe here the development of this new class of microscope and the principles of its operation, with examples of its application to problems in materials science.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New development of advanced superconducting electron cyclotron resonance ion source SECRAL (invited)

Superconducting electron cyclotron resonance ion source with advance design in Lanzhou (SECRAL) is an 18-28 GHz fully superconducting electron cyclotron resonance (ECR) ion source dedicated for highly charged heavy ion beam production. SECRAL, with an innovative superconducting magnet structure of solenoid-inside-sextupole and at lower frequency and lower rf power operation, may open a new way for developing compact and reliable high performance superconducting ECR ion source. One of the recent highlights achieved at SECRAL is that some new record beam currents for very high charge states were produced by 18 GHz or 18+14.5 GHz double frequency heating, such as 1 e {mu}A of {sup 129}Xe{sup 43+}, 22 e {mu}A of {sup 209}Bi{sup 41+}, and 1.5 e {mu}A of {sup 209}Bi{sup 50+}. To further enhance the performance of SECRAL, a 24 GHz/7 kW gyrotron microwave generator was installed and SECRAL was tested at 24 GHz. Some promising and exciting results at 24 GHz with new record highly charged ion beam intensities were produced, such as 455 e {mu}A of {sup 129}Xe{sup 27+} and 152 e {mu}A of {sup 129}Xe{sup 30+}, although the commissioning time was limited within 3-4 weeks and rf power only 3-4 kW. Bremsstrahlung measurements at 24 GHz show that x-ray is much stronger with higher rf frequency, higher rf power. and higher minimum mirror magnetic field (minimum B). Preliminary emittance measurements indicate that SECRAL emittance at 24 GHz is slightly higher that at 18 GHz. SECRAL has been put into routine operation at 18 GHz for heavy ion research facility in Lanzhou (HIRFL) accelerator complex since May 2007. The total operation beam time from SECRAL for HIRFL accelerator has been more than 2000 h, and {sup 129}Xe{sup 27+}, {sup 78}Kr{sup 19+}, {sup 209}Bi{sup 31+}, and {sup 58}Ni{sup 19+} beams were delivered. All of these new developments, the latest results, and long-term operation for the accelerator have again demonstrated that SECRAL is one of the best in the performance of ECR ion source for highly charged heavy ion beam production. Finally the future development of SECRAL will be presented.

43 PARTICLE ACCELERATORS↗

Time-of-flight spectroscopy of the energy distribution of laser-ablated atoms and ions

The growth of ultrathin films, deposited by laser ablation, crucially depends on the energy of the ablated species. Therefore, a time-of-flight (TOF) spectrometer has been constructed and measurements have been carried out in order to determine the energy distribution of laser-ablated Fe and Pt atoms and ions in the plasma created by nanosecond pulses of a frequency-doubled neodymium doped yttrium aluminum garnet laser. The experiments have been performed in ultrahigh vacuum at relatively low laser power. For measuring the spectra of the neutrals, a cross-beam electron source for postionization and electric as well as magnetic fields for repelling the ions are employed. Nevertheless, measurements of neutral particles are restricted to low plasma densities due to electrostatic shielding within the plasma, leading to an inefficient deflection of charged particles by electrostatic and magnetic fields. Test measurements have been performed by utilizing the TOF spectrometer as a pressure gauge and also by chopping the electron beam, running the TOF spectrometer as a residual gas mass spectrometer. The spectra of the laser-ablated plasmas have shown plasma conditions with a Debye length of approximately 10{sup -4} m, densities of 10{sup 15}-10{sup 16} m{sup -3} and ion energies up to 150 eV. Neutral spectra have shown an unexpectedly low fraction of neutrals (10{sup -3}-10{sup -4}) and hyperthermal energies up to several 10 eV, possibly contributed by recombination of ions and electrons in the plasma. Even though gas spectra had demonstrated the expected sensitivity of the TOF spectrometer for low-energy neutrals, no thermally evaporated neutral atoms could be found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design study of primary ion provider for relativistic heavy ion collider electron beam ion source

Brookhaven National Laboratory has developed the new preinjector system, electron beam ion source (EBIS) for relativistic heavy ion collider (RHIC) and National Aeronautics and Space Administration Space Radiation Laboratory. Design of primary ion provider is an essential problem since it is required to supply beams with different ion species to multiple users simultaneously. The laser ion source with a defocused laser can provide a low charge state and low emittance ion beam, and is a candidate for the primary ion source for RHIC-EBIS. We show a suitable design with appropriate drift length and solenoid, which helps to keep sufficient total charge number with longer pulse length. The whole design of primary ion source, as well as optics arrangement, solid targets configuration and heating about target, is presented.

43 PARTICLE ACCELERATORS↗

MTV-G experiment: Probing non-standard strong gravitational field at nuclear scale using geodetic precession

A new experiment named MTV-G, probing a large electron spin-precession due to a possible strong gravitational field, which predicted by large extra dimension model, is started at TRIUMF from 2011. In an electron-nuclear scattering experiment, a strong gravitational field is tested as a large spin precession effect caused by geodetic precession predicted by general relativity theory as a result of a warped space-time around nuclei. Experimental design using spin polarized electron source and Mott-spin analyzer, commissioning experiment and the preliminary results are described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A nanoemitter based on a superconducting material

The coherence of an electron beam is crucial for the performance of electron microscopy, coherent diffractive imaging, holography, and many other advanced instrumentation methods that rely on the phase coherence of electron waves. Here we present a reliable method for preparing a niobium nanoemitter, which is thermally and chemically stable. The tip apex is a (100) facet with a lateral dimension of ∼1 nm, surrounded by four (310) facets. Adsorption of one monolayer of noble gas, particularly Xe, onto the nanoemitter greatly enhances the emission current and current stability. This electron source will probably possess both spatial and temporal coherence if the emitter is cooled below the superconducting temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A high sensitivity ultralow temperature RF conductance and noise measurement setup

We report on the realization of a high sensitivity RF noise measurement scheme to study small current fluctuations of mesoscopic systems at milli-Kelvin temperatures. The setup relies on the combination of an interferometric amplification scheme and a quarter-wave impedance transformer, allowing the measurement of noise power spectral densities with gigahertz bandwidth up to five orders of magnitude below the amplifier noise floor. We simultaneously measure the high frequency conductance of the sample by derivating a portion of the signal to a microwave homodyne detection. We describe the principle of the setup, as well as its implementation and calibration. Finally, we show that our setup allows to fully characterize a subnanosecond on-demand single electron source. More generally, its sensitivity and bandwidth make it suitable for applications manipulating single charges at GHz frequencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Snowmass2021 Topical Group Report from AF07: Targets and Sources

For the next multi-megawatt accelerator generation, targets and other beam-intercepting components will face even more severe challenges due to the higher power densities, higher energy, and higher radiation. A comprehensive research and development program must be implemented to address the challenges. International collaborations such as RaDIATE or High Power Targetry Workshop should be leveraged and expanded to accelerate knowledge gain and avoid duplicated efforts. The next generation of high power targets will need novel designs allowing better high heat flux cooling methods, novel materials, advanced simulations, and better instrumentation. Four main R&D tracks were identified and discussed for targets. For electron sources, current state of art and challenges we are facing for key components such as cathodes, guns and injector design for sources R&D are presented for highly polarized electrons and unpolarized high current high brightness beams. For ion sources such as electron cyclotron resonance ion source (ECRIS), laser ion source (LIS), charge breeders, status of development are reviewed, and areas require investment for future R&D are discussed separately. Facilities critical for various source development are recommended.

43 PARTICLE ACCELERATORS↗

Ultrafast laser triggered electron emission from ultrananocrystalline diamond pyramid tip cathode

Nitrogen-incorporated ultrananocrystalline diamond [(N)UNCD] pyramid tip cathode has been considered as a next-generation high peak current electron source for dielectric laser accelerators as well as other high peak current particle accelerator applications. In this work, we study non-linear photoemission from an (N)UNCD pyramid tip cathode using an ultrafast laser with the pulse length of 150 fs with the central wavelength of 800 nm in the peak intensity range of 10 9 –10 10 W/cm 2 . We demonstrated that as the incident laser intensity increases, the current emitted from the nano-tip first increases as a power function with an exponent of about 5 and then starts to roll over to an exponent of 3. This roll over is attributed to the Coulomb interaction between electrons emitted from the tip also known as the space charge. We also measured the photoemission electron energy spectra that show electrons with energies as high as ~10 eV. Based on the shape of the electron energy spectra, we conclude that the high-energy electrons are thermally emitted electrons due to ultrafast laser heating at the tip of the (N)UNCD pyramid tip cathode.

43 PARTICLE ACCELERATORS↗

High-energy X-ray detection of G359.89–0.08 (SGR A–E): Magnetic flux tube emission powered by cosmic rays?

We report the first detection of high-energy X-ray (E > 10 keV) emission from the Galactic center non-thermal filament G359.89–0.08 (Sgr A–E) using data acquired with the Nuclear Spectroscopic Telescope Array (NuSTAR). The bright filament was detected up to ∼50 keV during a NuSTAR Galactic center monitoring campaign. The featureless power-law spectrum with a photon index Γ ≈ 2.3 confirms a non-thermal emission mechanism. The observed flux in the 3-79 keV band is F{sub X} = (2.0 ± 0.1) × 10{sup –12} erg cm{sup –2} s{sup –1}, corresponding to an unabsorbed X-ray luminosity L{sub X} = (2.6 ± 0.8) × 10{sup 34} erg s{sup –1} assuming a distance of 8.0 kpc. Based on theoretical predictions and observations, we conclude that Sgr A–E is unlikely to be a pulsar wind nebula (PWN) or supernova remnant-molecular cloud (SNR-MC) interaction, as previously hypothesized. Instead, the emission could be due to a magnetic flux tube which traps TeV electrons. We propose two possible TeV electron sources: old PWNe (up to ∼100 kyr) with low surface brightness and radii up to ∼30 pc or MCs illuminated by cosmic rays (CRs) from CR accelerators such as SNRs or Sgr A*.

79 ASTRONOMY AND ASTROPHYSICS↗