Search NASA⌕ Search

SEARCH · Search NASA

Results for “error mitigation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Ultracoherent superconducting cavity-based multiqudit platform with error-resilient control

Superconducting radio-frequency (SRF) cavities offer a promising platform for quantum computing due to their long coherence times, yet integrating nonlinear elements like transmons for control often introduces additional loss. We report a multimode quantum system based on a 2-cell elliptical shaped SRF cavity, comprising two cavity modes weakly coupled to an ancillary transmon circuit, designed to preserve coherence while enabling efficient control of the cavity modes. We mitigate the detrimental effects of the transmon decoherence through careful design optimization that reduces transmon-cavity couplings and participation in the dielectric substrate and lossy interfaces, to achieve single-photon lifetimes of 20.6 ms and 15.6 ms for the two modes, and a pure dephasing time exceeding 40 ms. This marks an order-of-magnitude improvement over prior 3D multimode memories. Leveraging sideband interactions and novel error-resilient protocols, including measurement-based correction and post-selection, we achieve high-fidelity control over quantum states. This enables the preparation of Fock states up to $N = 20$ with fidelities exceeding 95%, the highest reported to date to the authors' knowledge, as well as two-mode entanglement with an estimated coherence-limited fidelities of 99.9% after post-selection. These results establish our platform as a robust foundation for quantum information processing, allowing for future extensions to high-dimensional qudit encodings.

Kim, Taeyoon [Fermilab; Northwestern U.]↗

Solid State Transformer Controls for Mitigation of E3a High-Altitude Electromagnetic Pulse Insults

This paper explores the use of a solid state transformer (SST) to mitigate the 𝐸 3𝐴 component of a high-altitude electromagnetic pulse (HEMP) insult using external energy storage optimal control techniques. In lieu of conventional passive blocking devices or feedback-controlled energy storage devices, a novel implementation of Hamiltonian error tracking is utilized to develop a feedback control law for the variable converter ratio in an SST. The findings of the simulations performed in this paper suggest that additional energy storage is not necessary to protect an individual load from a HEMP insult. The simulations performed examine the response of a single-phase SST connected to a single voltage source on a long transmission line on the one side and a single linear resistor on the other. The control law is specifically developed for the late-time, low-frequency portion of a HEMP insult, namely the 𝐸 3𝐴 components. The Hamiltonian error-based converter ratio control law is compared with nonlinear optimal feedforward controls to show that the HSSPFC is an external energy storage optimal controller.

HEMP mitigation↗

Ultracoherent superconducting cavity-based multiqudit platform with error-resilient control

Superconducting radio-frequency (SRF) cavities offer a promising platform for quantum computing due to their long coherence times, yet integrating nonlinear elements like transmons for control often introduces additional loss. We report a multimode quantum system based on a 2-cell elliptical-shaped SRF cavity, comprising two cavity modes weakly coupled to an ancillary transmon circuit, designed to preserve coherence while enabling efficient control of the cavity modes. We mitigate the detrimental effects of the transmon decoherence through careful design optimization that reduces transmon-cavity couplings and participation in the dielectric substrate and lossy interfaces, to achieve single-photon lifetimes of 20.6 ms and 15.6 ms for the two modes, and a pure dephasing time exceeding 40 ms. This marks an order-of-magnitude improvement over prior 3D multimode memories. Leveraging sideband interactions and novel error-resilient protocols, including measurement-based correction and post-selection, we achieve high-fidelity control over quantum states. This enables the preparation of Fock states up to N = 20 with fidelities exceeding 95%, the highest reported to date to the authors' knowledge, as well as two-mode entanglement with an estimated coherence-limited fidelities of 99.9% after post-selection. These results establish our platform as a robust foundation for quantum information processing, allowing for future extensions to high-dimensional qudit encodings.

Lu, Yao [Fermilab] (ORCID:000000020413698X)↗

Ultracoherent superconducting cavity-based multiqudit platform with error-resilient control

Superconducting radio-frequency (SRF) cavities offer a promising platform for quantum computing due to their long coherence times, yet integrating nonlinear elements like transmons for control often introduces additional loss. We report a multimode quantum system based on a 2-cell elliptical-shaped SRF cavity, comprising two cavity modes weakly coupled to an ancillary transmon circuit, designed to preserve coherence while enabling efficient control of the cavity modes. We mitigate the detrimental effects of the transmon decoherence through careful design optimization that reduces transmon-cavity couplings and participation in the dielectric substrate and lossy interfaces, to achieve single-photon lifetimes of 20.6 ms and 15.6 ms for the two modes, and a pure dephasing time exceeding 40 ms. This marks an order-of-magnitude improvement over prior 3D multimode memories. Leveraging sideband interactions and novel error-resilient protocols, including measurement-based correction and post-selection, we achieve high-fidelity control over quantum states. This enables the preparation of Fock states up to N = 20 with fidelities exceeding 95%, the highest reported to date to the authors' knowledge, as well as two-mode entanglement with an estimated coherence-limited fidelities of 99.9% after post-selection. These results establish our platform as a robust foundation for quantum information processing, allowing for future extensions to high-dimensional qudit encodings.

Lu, Yao [Fermilab] (ORCID:000000020413698X)↗

Implications of the fractional charge of hydroxide at the electrochemical interface

Rational design of materials that efficiently convert electrical energy into chemical bonds will ultimately depend on a thorough understanding of the electrochemical interface at the atomic level. Towards this goal, the use of density functional theory (DFT) at the generalized gradient approximation (GGA) level has been applied widely in the past 15 years. In the calculation of electrochemical reaction energetics using GGA-DFT, it is frequently implicitly assumed that ions in the Helmholtz plane have unit charge. However, the ion charge is observed to be fractional near the interface through both a capacitor model and through Bader charge partitioning. In this work, we show that this spurious charge transfer can be effectively mitigated by continuum charging of the electrolyte. Finally, we show that, similar to hydronium, the observed fractional charge of hydroxide is not due to a GGA level self-interaction error, as the partial charge is observed even when using hybrid level exchange–correlation functionals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel Technique for Developing Linearized Convex System Models from Experimentally Derived Data

This paper presents a novel technique for generating a convex system model from an experimentally derived data set which features variance among repeated measurements. The convex system model developed as a test case characterizes the dynamic system losses of a vanadium redox flow battery as a function of the active power output and the battery state of charge. The technique hinges on a pre-cleaning via clustering procedure which precedes the formation of a planar convex hull comprised of triangular simplices. The clustering procedure efficiently reduces the experimental data set while mitigating variance among repeated measurements and removes outliers. Ultimately, the lower evelope of the planar convex hull serves as the desired convex system model. The proposed technique reduces systematic model error which is otherwise present when directly developing a planar convex hull model based on an unreduced data set.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TU-FG-201-11: Evaluating the Validity of Prospective Risk Analysis Methods: A Comparison of Traditional FMEA and Modified Healthcare FMEA

Purpose: To examine the ability of traditional Failure mode and effects analysis (FMEA) and a light version of Healthcare FMEA (HFMEA), called Scenario analysis of FMEA (SAFER) by comparing their outputs in terms of the risks identified and their severity rankings. Methods: We applied two prospective methods of the quality management to surface image guided, linac-based radiosurgery (SIG-RS). For the traditional FMEA, decisions on how to improve an operation are based on risk priority number (RPN). RPN is a product of three indices: occurrence, severity and detectability. The SAFER approach; utilized two indices-frequency and severity-which were defined by a multidisciplinary team. A criticality matrix was divided into 4 categories; very low, low, high and very high. For high risk events, an additional evaluation was performed. Based upon the criticality of the process, it was decided if additional safety measures were needed and what they comprise. Results: Two methods were independently compared to determine if the results and rated risks were matching or not. Our results showed an agreement of 67% between FMEA and SAFER approaches for the 15 riskiest SIG-specific failure modes. The main differences between the two approaches were the distribution of the values and the failure modes (No.52, 54, 154) that have high SAFER scores do not necessarily have high FMEA RPN scores. In our results, there were additional risks identified by both methods with little correspondence. In the SAFER, when the risk score is determined, the basis of the established decision tree or the failure mode should be more investigated. Conclusion: The FMEA method takes into account the probability that an error passes without being detected. SAFER is inductive because it requires the identification of the consequences from causes, and semi-quantitative since it allow the prioritization of risks and mitigation measures, and thus is perfectly applicable to clinical parts of radiotherapy.

60 APPLIED LIFE SCIENCES↗

Heat Transfer Salts for Nuclear Reactor Systems - Chemistry Control, Corrosion Mitigation, and Modeling

The concept of a molten salt reactor has existed for nearly sixty years. Previously all work was done during a large collaborative effort at Oak Ridge National Laboratory, culminating in a research reactor which operated for 15,000 hours without major error. This technical success has garnished interest in modern, high temperature, reactor schemes. Research using molten fluoride salts for nuclear applications requires a steady supply of high grade molten salts. There is no bulk supplier of research grade fluoride salts in the world, so a facility which could provide all the salt needed for testing at the University of Wisconsin had to be produced. Two salt purification devices were made for this purpose, a large scale purifier, and a small scale purifier, each designed to clean the salts from impurities and reduce their corrosion potential. As of now, the small scale has performed with flibe salt, hydrogen, and hydrogen fluoride, yielding clean salt. This salt is currently being used in corrosion testing facilities at the Massachusetts Institute of Technology and the University of Wisconsin. Working with the beryllium based salts requires extensive safety measures and health monitoring to prevent the development of acute or chronic beryllium disease, two pulmonary diseases created by an allergic reaction to beryllium in the lungs. Extensive health monitoring, engineering controls, and environment monitoring had to be set up with the University of Wisconsin department of Environment, Health and Safety. The hydrogen fluoride required for purification was also an extreme health hazard requiring thoughtful planning and execution. These dangers have made research a slow and tedious process. Simple processes, such as chemical handling and clean-up, can take large amounts of ingenuity and time. Other work has complemented the experimental research at Wisconsin to advance high temperature reactor goals. Modeling work has been performed in house to re-evaluate thermophysical properties of flibe and flinak. Pacific Northwest National Laboratories has focused on evaluating the fluorinating gas nitrogen trifluoride as a potential salt purification agent. Work there was performed on removing hydroxides and oxides from flinak salt under controlled conditions. Lastly, the University of California Berkeley has spent considerable time designing and simulating reactor components with fluoride salts at high temperatures. Despite the hurdles presented by the innate chemical hazards, considerable progress has been made. The stage has been set to perform new research on salt chemical control which could advance the fluoride salt cooled reactor concept towards commercialization. What were previously thought of as chemical undesirable, but nuclear certified, alloys have been shown to be theoretically compatible with fluoride salts at high temperatures. This preliminary report has been prepared to communicate the construction of the basic infrastructure required for flibe, as well as suggest original research to performed at the University of Wisconsin. Simultaneously, the contents of this report can serve as a detailed, but introductory guide to allow anyone to learn the fundamentals of chemistry, engineering, and safety required to work with flibe salt.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Systematic and statistical uncertainties of the hilbert-transform based high-precision FID frequency extraction method

Pulsed nuclear magnetic resonance (NMR) is widely used in high-precision magnetic field measurements. The absolute value of the magnetic field is determined from the precession frequency of nuclear magnetic moments. The Hilbert transform is widely used to extract the phase function from the observed free induction decay (FID) signal and then its frequency. In this paper, a detailed implementation of a Hilbert-transform based FID frequency extraction method is described. How artifacts and noise level in the FID signal affect the extracted phase function are derived analytically. A method of mitigating the artifacts in the extracted phase function of an FID is discussed. Correlations between noises of the phase function samples are studied for different noise spectra. We discovered that the error covariance matrix for the extracted phase function is nearly singular and improper for constructing the $\chi^2$ used in the fitting routine. A down-sampling method for fixing the singular covariance matrix has been developed, so that the minimum $\chi^2$-fit yields properly the statistical uncertainty of the extracted frequency. Other practical methods of obtaining the statistical uncertainty are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impacts of hybridization and forecast errors on the probabilistic capacity credit of batteries

Battery storage is increasingly identified as being among the least-cost mix of technologies in the evolving U.S. electricity mix. This study explores the marginal capacity credit of batteries using a probabilistic, reliability-based, effective firm capacity method, which we apply for multiple battery power ratings, durations, coupling types, deployment locations, and dispatch profiles within a test system that is based on the Texas Interconnection in the year 2024. We find that the capacity credits for all battery durations depend on their ability to predict the timing of reliability events. Even 1-2 h forecast errors - resulting in early or delayed battery discharging relative to the onset of a reliability event - lead pronounced capacity credit reductions, especially for 4-h duration batteries. Coupling batteries with solar mitigates the uncertainty associated with a shorter-duration battery's availability during reliability events, primarily due to the relatively high solar capacity credit in our test system. Coupled (or hybrid) system designs with oversized solar arrays, the ability to charge the coupled battery with grid energy, and larger batteries lead to the greatest capacity credit benefits of hybridization. We do not see evidence that the hybrid capacity credit exceeds the sum of the separate battery and solar capacity credits.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tula: Optimizing Time, Cost, and Generalization in Distributed Large-Batch Training

Distributed training increases the number of batches processed per iteration either by scaling-out (adding more nodes) or scaling-up (increasing the batch-size). However, the largest configuration does not necessarily yield the best performance. Horizontal scaling introduces additional communication overhead, while vertical scaling is constrained by computation cost and device memory limits. Thus, simply increasing the batch-size leads to diminishing returns: training time and cost decrease initially but eventually plateaus, creating a knee-point in the time/cost vs. batch-size pareto curve. The optimal batch-size therefore depends on the underlying model, data and available compute resources. Large batches also suffer from worse model quality due to the well-known “generalization gap”. In this paper, we present Tula, an online service that automatically optimizes time, cost, and convergence quality for large-batch training of convolutional models. It combines parallel-systems modeling with statistical performance prediction to identify the optimal batchsize. Tula predicts training time and cost within 7.5−14% error across multiple models, and achieves up to 20× overall speedup and improves test accuracy by ≈9% on average over standard large-batch training on various vision tasks, thus successfully mitigating the generalization gap and accelerating training at the same time.

Tyagi, Sahil [ORNL] (ORCID:0009000783144745)↗

Causal Analysis of the Inadvertent Contact with an Uncontrolled Electrical Hazardous Energy Source (120 Volts AC)

On September 25, 2013, a Health Physics Technician (HPT) was performing preparations to support a pneumatic transfer from the HFEF Decon Cell to the Room 130 Glovebox in HFEF, per HFEF OI 3165 section 3.5, Field Preparations. This activity involves an HPT setting up and climbing a portable ladder to remove the 14-C meter probe from above ball valve HBV-7. The HPT source checks the meter and probe and then replaces the probe above HBV-7, which is located above Hood ID# 130 HP. At approximately 13:20, while reaching past the HBV-7 valve position indicator switches in an attempt to place the 14-C meter probe in the desired location, the HPT’s left forearm came in contact with one of the three sets of exposed terminals on the valve position indication switches for HBV 7. This resulted in the HPT receiving an electrical shock from a 120 Volt AC source. Upon moving the arm, following the electrical shock, the HPT noticed two exposed electrical connections on a switch. The HPT then notified the HFEF HPT Supervisor, who in turn notified the MFC Radiological Controls Manager and HFEF Operations Manager of the situation. Work was stopped in the area and the hazard was roped off and posted to prevent access to the hazard. The HPT was escorted by the HPT Supervisor to the MFC Dispensary and then preceded to CFA medical for further evaluation. The individual was evaluated and released without any medical restrictions. Causal Factor (Root Cause) A3B3C01/A5B2C08: - Knowledge based error/Attention was given to wrong issues - Written Communication content LTA, Incomplete/situation not covered The Causal Factor (root cause) was attention being given to the wrong issues during the creation, reviews, verifications, and actual performance of HFEF OI-3165, which covers the need to perform the weekly source check and ensure placement of the probe prior to performing a “rabbit” transfer. This resulted in the hazard not being identified and mitigated in the procedure. Work activities with in HFEF-OI-3165 placed the HPT in proximity of an unmitigated hazard directly resulting in this event. Contributing Factor A3B3C04/A4B5C04: - Knowledge Based Error, LTA Review Based on Assumption That Process Will Not Change - Change Management LTA, Risks/consequences associated with change not adequately reviewed/assessed Prior to the pneumatic system being out of service, the probe and meter were not being source checked together. The source check issue was identified and addressed during the period of time when the system was out of service. The corrective actions for this issue resulted in the requirement that a meter and probe be source checked together as it is intended to be used. This changed the activity and required an HPT to weekly, when in use, remove and install the probe from above HBV-7 to meet the requirement of LRD 15001 Part 5 Article 551.5. Risks and consequences associated with this change were not adequately reviewed or assessed. Failure to identify the hazard associated with this change directly contributed to this event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Active Optics System on the Vera C. Rubin Observatory: Optimal Control of Degeneracy among the Large Number of Degrees of Freedom

Abstract The Vera C. Rubin Observatory is a unique facility for survey astronomy that will soon be commissioned and begin operations. Crucial to many of its scientific goals is the achievement of sustained high image quality, limited only by the seeing at the site. This will be maintained through an active optics system that controls optical element misalignments and corrects mirror figure error to minimize aberrations caused by both thermal and gravitational effects. However, the large number of adjustment degrees of freedom available on the Rubin Observatory introduces a range of degeneracies, including many that are induced by noise due to imperfect measurement of the wave-front errors. We present a structured methodology for identifying these degeneracies through an analysis of image noise level. We also present a novel scaling strategy based on truncated singular value decomposition that mitigates the degeneracy and optimally distributes the adjustment over the available degrees of freedom. Our approach ensures the attainment of optimal image quality, while avoiding excursions around the noise-induced subspace of degeneracies, marking a significant improvement over the previous techniques adopted for Rubin, which were based on an optimal integral controller. This new approach is likely to also yield significant benefits for all telescopes that incorporate large numbers of degrees of freedom of adjustment.

79 ASTRONOMY AND ASTROPHYSICS↗

Full circle mechanical dynamic characterization including experimental modal analysis and finite element analysis

During operation, it was observed that a specific mechanical system experienced undesirable vibration and it became necessary to understand and mitigate this phenomenon. This document investigates the tools, methodology, and results of the dynamic characterization of the system. The characterization makes use of the experimental modal analysis (EMA) methods of single input multiple output (SIMO) and single input single output (SISO). The validity of the theory of reciprocity is confirmed to minimize measurement error, cost, and time of repeat testing. Finite element analysis (FEA) is used in choosing transducer and modal impact locations to adequately characterize the system. Single degree of freedom (SDOF) and multiple degree of freedom (MDOF) curve fitting is used to fully characterize the system’s mode shapes and natural frequencies. The EMA characterization results are used to modify and validate the FEA model so that FEA can be used to model potential structural modifications to the system to mitigate the undesirable vibration. Structural modifications are chosen, implemented, and their effectiveness is quantified using EMA. Finally, a qualitative evaluation of the methodology of FEA validation by EMA and tuning of the model to match the experimental results is discussed.

42 ENGINEERING↗

CMB temperature lensing power reconstruction

We study the reconstruction of the lensing potential power spectrum from CMB temperature data, with an eye to the Planck experiment. We work with the optimal quadratic estimator of Okamoto and Hu, which we characterize thoroughly in an application to the reconstruction of the lensing power spectrum. We find that at multipoles L<250, our current understanding of this estimator is biased at the 15% level by beyond-gradient terms in the Taylor expansion of lensing effects. We present the full lensed trispectrum to fourth order in the lensing potential to explain this effect. We show that the low-L bias, as well as a previously known bias at high L, is relevant to the determination of cosmology and must be corrected for in order to avoid significant parameter errors. We also investigate the covariance of the reconstructed power, finding broad correlations of {approx_equal}0.1%. Finally, we discuss several small improvements which may be made to the optimal estimator to mitigate these problems.

79 ASTRONOMY AND ASTROPHYSICS↗

Spherical geodesic mesh generation

In ALE simulations with moving meshes, mesh topology has a direct influence on feature representation and code robustness. In three-dimensional simulations, modeling spherical volumes and features is particularly challenging for a hydrodynamics code. Calculations on traditional spherical meshes (such as spin meshes) often lead to errors and symmetry breaking. Although the underlying differencing scheme may be modified to rectify this, the differencing scheme may not be accessible. This work documents the use of spherical geodesic meshes to mitigate solution-mesh coupling. These meshes are generated notionally by connecting geodesic surface meshes to produce triangular-prismatic volume meshes. This mesh topology is fundamentally different from traditional mesh topologies and displays superior qualities such as topological symmetry. This work describes the geodesic mesh topology as well as motivating demonstrations with the FLAG hydrocode.

97 MATHEMATICS AND COMPUTING↗

Improving Vertical Velocity Retrievals from Doppler Radar Observations of Convection Field Campaign Report

Our National Science Foundation (NSF)-supported project was designed to address two longstanding challenges in radar-, meso-scale-, and hydro-meteorology: (1) mitigating the effects of non-simultaneous data collection on radar data-based analysis products, and (2) improving estimates of the vertical velocity (w) field in dual-Doppler wind analyses. Errors associated with the non-simultaneous data collection introduce errors in all Doppler analyses, and impose a lower limit on the time and space scales that can be studied. For many investigations the w field is of prime meteorological importance, but it is the velocity component most difficult to accurately synthesize from dual-Doppler wind observations. Our original plan proposed for short field campaigns at the Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) Central Facility (CF) was to use multiple-Doppler radial wind data from the scanning ARM X-band radars to test and refine our multiple-Doppler wind analysis algorithms. An important part of our plan was the use of high-temporal-resolution w observations to verify the analyses. In our original plan, these data would be obtained from Doppler lidars, 915 MhZ profilers and Ka-band ARM Zenith Radar (KAZR) zenith-pointing radars at the CF and nearby ARM facilities in north-central Oklahoma. Using the data, we planned to test the utility of new spatially variable advection-correction/analysis procedures, the utility of the anelastic vertical vorticity equation as a constraint in variational multiple-Doppler wind analysis, and other Doppler wind analysis procedures. Idealized tests with numerically-simulated supercell data had suggested the vorticity constraint could help improve the vertical velocity field if the data were gathered with sufficiently high temporal resolution (e.g., volume scans completed in 30-60 sec), so we were interested in exploring the use of rapid-scan data from the X-band Scanning ARM Precipitation Radars (XSAPRs).

Southern Great Plains, convection, KAZR, XSAPR, ve↗