Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Automated Controller Hardware-In-The-Loop Testbed for EV Charger Resilience Analysis

This paper focuses on the development of a tool that includes an automated testbed with controls, protection, and communications integrated into a real-time system to provide a platform to generate data sets for failure modes and effects analysis. This tool establishes a value for automation of data generation for different scenarios and addresses the gap of nonexistent field data for different applications and use cases. The features of this tool can further be expanded to include multiple power electronics models, communication protocols, and scaled system architectures. This general framework was evaluated for a DC fast charger system use case to provide quantitative solution for resiliency.

Starke, Michael↗

Quality Assurance Framework for Mini-Grids

Providing clean and affordable energy services to the more than 1 billion people globally who lack access to electricity is a critical driver for poverty reduction, economic development, improved health, and social outcomes. More than 84% of populations without electricity are located in rural areas where traditional grid extension may not be cost-effective; therefore, distributed energy solutions such as mini-grids are critical. To address some of the root challenges of providing safe, quality, and financially viable mini-grid power systems to remote customers, the U.S. Department of Energy (DOE) teamed with the National Renewable Energy Laboratory (NREL) to develop a Quality Assurance Framework (QAF) for isolated mini-grids. The QAF for mini-grids aims to address some root challenges of providing safe, quality, and affordable power to remote customers via financially viable mini-grids through two key components: (1) Levels of service: Defines a standard set of tiers of end-user service and links them to technical parameters of power quality, power availability, and power reliability. These levels of service span the entire energy ladder, from basic energy service to high-quality, high-reliability, and high-availability service (often considered 'grid parity'); (2) Accountability and performance reporting framework: Provides a clear process of validating power delivery by providing trusted information to customers, funders, and/or regulators. The performance reporting protocol can also serve as a robust monitoring and evaluation tool for mini-grid operators and funding organizations. The QAF will provide a flexible alternative to rigid top-down standards for mini-grids in energy access contexts, outlining tiers of end-user service and linking them to relevant technical parameters. In addition, data generated through implementation of the QAF will provide the foundation for comparisons across projects, assessment of impacts, and greater confidence that will drive investment and scale-up in this sector. The QAF implementation process also defines a set of implementation guidelines that help the deployment of mini-grids on a regional or national scale, helping to insure successful rapid deployment of these relatively new remote energy options. Note that the QAF is technology agnostic, addressing both alternating current (AC) and direct current (DC) mini-grids, and is also applicable to renewable, fossil-fuel, and hybrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dip leg plug formation evaluation and abatement testing in support of the H-Canyon accelerated basin de-inventory

As requested in the Technical Task Request (TTR), the Savannah River National Laboratory (SRNL) performed testing on the current typical bubbler dip leg design used in the H-Area Canyon (HCA). The TTR has a functional classification of General Services. Testing was initiated to ascertain if the plugging described in the TTR could be reproduced and, if so, to obtain general metrics on the resulting plugging dynamics, and evaluate possible mitigating methods, including design changes and cleaning/purging protocols. The bubblers were to be suspended in a simulant typical of H-Canyon solutions containing aluminum nitrate and silica at a temperature of 25°C using a nominal bubbler air flowrate of 7.5 SCFH. Emphasis was placed on minimizing equipment changes necessary to accomplish the mitigations, as equipment changes in the existing facility would be costly. Testing evolved into four (4) phases, concluding that plugging could indeed be reproduced (believed to be attributed to localized evaporation and bridging of crystals in the dip legs). During testing, plug formation information was obtained, including time, pressure, and temperature traces leading to plugging were defined; solution compositions leading to plugging were determined, and various physical characteristics (visual and mechanical) of the crystallized plug were obtained.

42 ENGINEERING↗

Assessment of the efficacy of medical countermeasures in space flight

Changes in body fluids, electrolytes and muscle mass are manifestations of adaptation to space flight and readaptation to the 1-g environment. The purpose of this paper is to review the current knowledge of biomedical responses to short- and long-duration space missions and to assess the efficacy of countermeasures to 1-g deconditioning. Exercise protocols, fluid hydration, dietary and potential pharmacologic measures are evaluated, and directions for future research activities are recommended.

Nicogossian, A.↗

Assessment of the efficacy of medical countermeasures in space flight

Changes in body fluids, electrolytes, and muscle mass are manifestations of adaptation to space flight and readaptation to the 1-g environment. The purposes of this paper are to review the current knowledge of biomedical responses to short- and long-duration space missions and to assess the efficacy of countermeasures to 1-g conditioning. Exercise protocols, fluid hydration, dietary and potential pharmacologic measures are evaluated, and directions for future research activities are recommended.

Nicogossian, A. E.↗

MR imaging of hand microcirculation as a potential tool for space glove testing and design

The task of evaluating and designing space gloves requires accurate biomechanical characterization of the hand. The availability of magnetic resonance (MR) imaging has created new opportunities for in vivo analysis of physiological phenomena such as the relationship between circulation and fatigue. An MR imaging technique originally proposed to quantitatively evaluate cerebral perfusion has been modified to evaluate the capillary microcirculation in hand muscles. An experimental protocol was developed to acquire perfusion-weighted images in the hand before and after various levels of exercise. Preliminary results on the feasibility of applying the MR imaging technique to the study of microcirculation and fatigue in the hand are presented. The potential of this method for space glove testing and design is also discussed.

Peterson, Steven W.↗

Assessment of the efficacy of medical countermeasures in space flight

Changes in body fluids, electrolytes, and muscle mass are manifestations of adaptation to space flight and readaptation to the 1-g environment. The purposes of this paper are to review the current knowledge of biomedical responses to short- and long-duration space missions and to assess the efficacy of countermeasures to 1-g conditioning. Exercise protocols, fluid hydration, dietary and potential pharmacologic measures are evaluated, and directions for future research activities are recommended.

NASA Discipline General Space Life Sciences↗

Ground-Based Measurements and Validation Protocols for Flex

The upcoming ESA Fluorescence Explorer (FLEX) mission will incorporate ground-based validations for fluorescence parameters and reflectance indices, drawing on an international network of sensors located at eddy covariance tower sites. A program has been initiated by the OPTIMISE program to develop methods and protocols for this network. A sensor system suite under evaluation by OPTIMISE includes the FLoX hyperspectral spectroradiometers. The NASA team at GSFC is participating in this experiment and we report first results from the 2017 summer measurements made above the canopy at the USDA/ARS Beltsville cornfield using the DFLoX and two other leaf-level measurement systems, the MONI-PAM and the FluoWat.

DFLOX↗

Future CH4 Budgets as Modelled By A Fully Coupled Earth System Model Using Prescribed GHG Concentrations vs. Interactive CH4 Sources and Sinks

We have used the NASA Goddard Institute for Space Studies (GISS) Earth system model GISS-E2.1 to study the future budgets and trends of global and regional CH4 under different emission scenarios. GISS-E2.1 is one of the few ESMs that can be driven by anthropogenic CH4 emissions, as well as interactive natural sources such as wetlands, and can simulate the tropospheric CH4 chemistry. In frame of the recent short-lived climate forcers (SLCFs) assessment by the Arctic Monitoring and Assessment Programme (AMAP), we used the GISS-E2.1 model with prescribed long-lived greenhouse gas (GHG) concentrations. In the present study, we have supplemented these simulations using the interactive CH4 sources and sinks in order to quantify the model performance and the sensitivity to CH4 sources and sinks. We have used the Current Legislation (CLE) and the Maximum Feasible Reduction (MFR) emission scenarios from the Eclipse V6b emission database to simulate the future chemical composition and climate impacts from 2015 to 2050. We have also simulated 1995-2014 in order to evaluate the model performance following the AMAP-SLCF protocol. The prescribed GHG version underestimates the Global Atmospheric Watch (GAW) surface CH4 observations during the period between 1995 and 2023 by 1% [-8.4%-2.0%], with a correlation (r) of 0.71 [-0.41 0.99]. The largest underestimations are over the continental emission regions such as North America, Europe, and Asia, while biases are smallest over oceans. On the other hand, the simulation with interactive sources and sinks underestimates the GAW observations more than the prescribed simulation, by 18.5% [-25% -10.4%], with a lower r of 0.36 [-0.82 0.93]. Opposite to the prescribed simulation, the biases are largest over oceans and smaller over the continents, however they are still larger over land than the prescribed simulation. The interactive simulation, with large sources virtually over land and strong sink over oceans, has a land/ocean ratio larger than 1 while the prescribed simulation has this ratio equal to 1 as it distributes the global prescribed CH4 concentration equally in longitude over a given latitude. This clearly shows that the interactive sources and sinks should be represented in models in order to realistically simulate the chemical composition and the oxidative capacity of the atmosphere. As expected, the MFR scenario simulates lower global surface CH4 concentrations and burdens compared to the CLE scenario, however in both cases, global surface CH4 and burden continue to increase through 2050 compared to present day. In the CLE scenario, increases are largest over the equatorial belt, in particular over India and East China, while the MFR scenario shows increases over the whole Southern Hemisphere, however much smaller compared to CLE. Finally, the interactive simulation shows that the chemical CH4 sink increases in the CLE scenario, while it slightly decreases in the MFR, leading to a larger CH4 lifetime in the MFR scenario compared to in the CLE scenario.

CH4↗

Updates to NASA’S Break-in-Prebreathe Flight Rules Due to Type II Decompression Sickness Risk Considerations

Investigation of a central neurological decompression sickness (DCS) case during hypobaric ground testing at Johnson Space Center (JSC) identified a ~3 min break-in-prebreathe (BiP) late in the prebreathe (13 min prior to depressurization) as the leading credible cause for the DCS case. This occurred despite applicable prebreathe payback rules being followed. Applicable NASA rules, for ground and flight, directed 2:1 payback of breaks up to 10 min in duration, regardless of when a break occurs relative to depress. Breaks lasting longer than 10 min require a complete restart of the prebreathe protocol. The adequacy of NASA’s BiP rules was evaluated prior to resuming any hypobaric ground testing or International Space Station (ISS) extravehicular activity (EVA). Of particular interest to the authors was the timing of the BiP in relation to the overall prebreathe timeline. Although there exists no agreed-upon definition, a ‘late’ BiP means towards the end of the prebreathe period, and in particular, the last hour prior to depressurization. The following information sources were reviewed prior to formulating recommendations: i) the type II DCS case report and findings from the investigation; ii) documented rationale for existing flight rules, iii) consultations with subject matter experts involved in definition of existing flight rules (several of whom had since left NASA); iv) relevant published literature; v) tissue gas loading model estimates; and vi) NASA’s operational experience with late breaks in prebreathe.

Andrew F J Abercromby↗

Design and Testing of a 2-Hour Oxygen Prebreathe Protocol for Space Walks from the International Space Station

To develop and test a 2-hour prebreathe protocol for performing extravehicular activities (EVAs) from the International Space Station (ISS). Combinations of adynamia (non-walking), prebreathe exercise, and space suit donning options (10.2 vs. 14.7 psi) were evaluated, against timeline and consumable contraints to develop an operational 2- hour prebreathe protocol. Prospective accept/reject criteria were defined for decompression sickness (DCS) and venous gas emboli (VGE) from analysis of historical DCS data, combined with risk management of DCS under ISS mission circumstances. Maximum operational DCS levels were defined based on protecting for EVA capability with two crew-members at 95% confidence, throughout ISS lifetime (within the constraints of NASA DCS disposition policy JPG 1800.3). The accept/reject limits were adjusted for greater safety based on analysis of related medical factors. Monte-Carlo simulation was performed to design a closed sequential, multi-center human trial. Protocols were tested with 4 different prebreathe exercises (Phases I-IV), prior to exposure to 4.3 psi for 4 hrs. Subject selection, Doppler monitoring for VGE, test termination criteria, and DCS definitions were standardized. Phase I: upper and lower body exercises using dual-cycle ergometry (75% VO2 max for 10 min). Phase II: ergometry plus 24 min of light exercise (simulating space-suit preparations). Phase III: same 24 min of light exercise but no ergometry, and Phase IV: 56 min of light exercise without ergometry. A prebreathe procedure was accepted if, at 95% confidence, the incidence of DCS was less than 15% (with no Type II DCS), and Grade IV VGE was less than 20%.

Gernhardt, Michael L.↗

SU-F-T-272: Patient Specific Quality Assurance of Prostate VMAT Plans with Portal Dosimetry

Purpose: To evaluate the effectiveness of using the Portal Dosimetry (PD) method for patient specific quality assurance of prostate VMAT plans. Methods: As per institutional protocol all VMAT plans were measured using the Varian Portal Dosimetry (PD) method. A gamma evaluation criterion of 3%-3mm with a minimum area gamma pass rate (gamma <1) of 95% is used clinically for all plans. We retrospectively evaluated the portal dosimetry results for 170 prostate patients treated with VMAT technique. Three sets of criterions were adopted for re-evaluating the measurements; 3%-3mm, 2%-2mm and 1%-1mm. For all criterions two areas, Field+1cm and MLC-CIAO were analysed.To ascertain the effectiveness of the portal dosimetry technique in determining the delivery accuracy of prostate VMAT plans, 10 patients previously measured with portal dosimetry, were randomly selected and their measurements repeated using the ArcCHECK method. The same criterion used in the analysis of PD was used for the ArcCHECK measurements. Results: All patient plans reviewed met the institutional criteria for Area Gamma pass rate. Overall, the gamma pass rate (gamma <1) decreases for 3%-3mm, 2%-2mm and 1%-1mm criterion. For each criterion the pass rate was significantly reduced when the MLC-CIAO was used instead of FIELD+1cm. There was noticeable change in sensitivity for MLC-CIAO with 2%-2mm criteria and much more significant reduction at 1%-1mm. Comparable results were obtained for the ArcCHECK measurements. Although differences were observed between the clockwise verses the counter clockwise plans in both the PD and ArcCHECK measurements, this was not deemed to be statistically significant. Conclusion: This work demonstrates that Portal Dosimetry technique can be effectively used for quality assurance of VMAT plans. Results obtained show similar sensitivity compared to ArcCheck. To reveal certain delivery inaccuracies, the use of a combination of criterions may provide an effective way in improving the overall sensitivity of PD. Funding provided in part by the Prostate Ride for Dad, Kitchener-Waterloo, Canada.

60 APPLIED LIFE SCIENCES↗

TU-F-17A-08: The Relative Accuracy of 4D Dose Accumulation for Lung Radiotherapy Using Rigid Dose Projection Versus Dose Recalculation On Every Breathing Phase

Purpose: To investigate the accuracy of 4D dose accumulation using projection of dose calculated on the end-exhalation, mid-ventilation, or average intensity breathing phase CT scan, versus dose accumulation performed using full Monte Carlo dose recalculation on every breathing phase. Methods: Radiotherapy plans were analyzed for 10 patients with stage I-II lung cancer planned using 4D-CT. SBRT plans were optimized using the dose calculated by a commercially-available Monte Carlo algorithm on the end-exhalation 4D-CT phase. 4D dose accumulations using deformable registration were performed with a commercially available tool that projected the planned dose onto every breathing phase without recalculation, as well as with a Monte Carlo recalculation of the dose on all breathing phases. The 3D planned dose (3D-EX), the 3D dose calculated on the average intensity image (3D-AVE), and the 4D accumulations of the dose calculated on the end-exhalation phase CT (4D-PR-EX), the mid-ventilation phase CT (4D-PR-MID), and the average intensity image (4D-PR-AVE), respectively, were compared against the accumulation of the Monte Carlo dose recalculated on every phase. Plan evaluation metrics relating to target volumes and critical structures relevant for lung SBRT were analyzed. Results: Plan evaluation metrics tabulated using 4D-PR-EX, 4D-PR-MID, and 4D-PR-AVE differed from those tabulated using Monte Carlo recalculation on every phase by an average of 0.14±0.70 Gy, - 0.11±0.51 Gy, and 0.00±0.62 Gy, respectively. Deviations of between 8 and 13 Gy were observed between the 4D-MC calculations and both 3D methods for the proximal bronchial trees of 3 patients. Conclusions: 4D dose accumulation using projection without re-calculation may be sufficiently accurate compared to 4D dose accumulated from Monte Carlo recalculation on every phase, depending on institutional protocols. Use of 4D dose accumulation should be considered when evaluating normal tissue complication probabilities as well as in clinical situations where target volumes are directly inferior to mobile critical structures.

60 APPLIED LIFE SCIENCES↗

Evaluating the roles of electrolyte components on the passivation of silicon anodes

A protocol was recently developed to compare calendar life using a constant potential while monitoring the electrical current required to maintain the potential. Here, this calendar life protocol is used with electrolyte formulations containing various mole fractions of ethylene carbonate (EC), ethyl methyl carbonate (EMC), and LiPF 6 to elucidate the role each component plays in passivation for high silicon anodes. Together, EC and LiPF 6 lead to higher currents, and thus poorer passivation, whereas EMC acts as a spectator. The variation of the components' mole fraction also changes the solid-electrolyte interphase (SEI) composition, as measured by x-ray photoelectron spectroscopy. Importantly, higher LiPF 6 content leads to increased LiF as well as increased current, indicating that higher LiF content does not enhance the passivation of the silicon surface. Finding that EC did not yield a passivating SEI, instead ethylene sulfite, sulfolane, and propylene carbonate (PC) were used in place of EC. Using ethylene sulfite and sulfolane resulted in poorer passivation compared to EC, whereas PC resulted in superior passivation. As a result, the superior passivation may be related to more stable lithium-solvent complexes.

25 ENERGY STORAGE↗

Experimental Benchmarking for High-Reproducibility, Cross-Institutional Evaluation of Iron Redox Electrochemistry

We present a practical case study standardizing experimental protocols between collaborators with the goal of understanding ferrous iron (Fe 2+ ) chemistry and improving the iron deposition reaction for energy-efficient, electrochemical iron production. The study of iron reactions can be difficult, as aqueous iron electrolytes exhibit complex behaviors that can lead to differing interpretation of ostensibly similar experiments. The question we want to answer: are we studying the same chemistry? Our protocols address inherent challenges such as the tendency for Fe 2+ to spontaneously oxidize to ferric iron (Fe 3+ ) and the production of hydrogen at the potentials of interest. Our standardized protocol, executed by four collaborators in different labs and institutions, yields high-reproducibility results, and identified glassy carbon electrode surface quality and Fe 3+ impurities in the salt as key factors with outsized effects on cyclic voltammetry measurements. The process of developing the protocols helped to troubleshoot underlying issues that created poorer reversibility and reproducibility. This study highlights the fact that even nominally straightforward electrochemical systems can yield vastly different outcomes due to small differences in experimental preparation and serves as a useful example for creating transparent and achievable standards for the generation of reliable datasets that can be widely used and shared.

Ketter, Benjamin [Argonne National Laboratory (ANL↗

Evaluation of Experimental Parameters in the Accelerated Aging of Closed-Cell Foam Insulation

The thermal conductivity of many closed-cell foam insulation products changes over time as production gases diffuse out of the cell matrix and atmospheric gases diffuse into the cells. Thin slicing has been shown to be an effective means of accelerating this process in such a way as to produce meaningful results. Efforts to produce a more prescriptive version of the ASTM C1303 standard test method led to the ruggedness test described here. This test program included the aging of full size insulation specimens for time periods of five years for direct comparison to the predicted results. Experimental parameters under investigation include: slice thickness, slice origin (at the surface or from the core of the slab), thin slice stack composition, product facings, original product thickness, product density, and product type. The test protocol has been completed and this report provides a detailed evaluation of the impact of the test parameters on the accuracy of the 5-year thermal conductivity prediction.

Stovall, Therese K.↗

Final Report for research grant entitled "Development of Reagents for Application of At-211 and Bi-213 to Targeted Radiotherapy of Cancer"

This grant was a one-year extension of another grant with the same title (DE-FG03-98ER62572). The objective of the studies was to continue in vivo evaluation of reagents to determine which changes in structure were most favorable for in vivo use. The focus of our studies was development and optimization of reagents for pretargeting alpha-emitting radionuclides At-211 or Bi-213 to cancer cells. Testing of the reagents was conducted in vitro and in animal model systems. During the funding period, all three specific aims set out in the proposed studies were worked on, and some additional studies directed at development of a method for direct labeling of proteins with At-211 were investigated. We evaluated reagents in two different approaches in 'two step' pretargeting protocols. These approaches are: (1) delivery of the radionuclide on recombinant streptavidin to bind with pretargeted biotinylated monoclonal antibody (mAb), and alternatively, (2) delivery of the radionuclide on a biotin derivative to bind with pretargeted antibody-streptavidin conjugates. The two approaches were investigated as it was unclear which will be superior for the short half-lived alpha-emitting radionuclides.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗