Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

An optimized approach and inflation media for obtaining complimentary mass spectrometry-based omics data from human lung tissue

Human disease states are biomolecularly multifaceted and can span across phenotypic states, therefore it is important to understand diseases on all levels, across cell types, and within and across microanatomical tissue compartments. To obtain an accurate and representative view of the molecular landscape within human lungs, this fragile tissue must be inflated and embedded to maintain spatial fidelity of the location of molecules and minimize molecular degradation for molecular imaging experiments. Here, we evaluated agarose inflation and carboxymethyl cellulose embedding media and determined effective tissue preparation protocols for performing bulk and spatial mass spectrometry-based omics measurements. Mass spectrometry imaging methods were optimized to boost the number of annotatable molecules in agarose inflated lung samples. This optimized protocol permitted the observation of unique lipid distributions within several airway regions in the lung tissue block. Laser capture microdissection of these airway regions followed by high-resolution proteomic analysis allowed us to begin linking the lipidome with the proteome in a spatially resolved manner, where we observed proteins with high abundance specifically localized to the airway regions. We also compared our mass spectrometry results to lung tissue samples preserved using two other inflation/embedding media, but we identified several pitfalls with the sample preparation steps using this preservation method. Overall, we demonstrated the versatility of the inflation method, and we can start to reveal how the metabolome, lipidome, and proteome are connected spatially in human lungs and across disease states through a variety of different experiments.

59 BASIC BIOLOGICAL SCIENCES↗

Heterogeneous Multi-Domain Dataset Synthesis to Facilitate Privacy and Risk Assessments in Smart City IoT

The emergence of the Smart Cities paradigm and the rapid expansion and integration of Internet of Things (IoT) technologies within this context have created unprecedented opportunities for high-resolution behavioral analytics, urban optimization, and context-aware services. However, this same proliferation intensifies privacy risks, particularly those arising from cross-modal data linkage across heterogeneous sensing platforms. To address these challenges, this paper introduces a comprehensive, statistically grounded framework for generating synthetic, multimodal IoT datasets tailored to Smart City research. The framework produces behaviorally plausible synthetic data suitable for preliminary privacy risk assessment and as a benchmark for future re-identification studies, as well as for evaluating algorithms in mobility modeling, urban informatics, and privacy-enhancing technologies. As part of our approach, we formalize probabilistic methods for synthesizing three heterogeneous and operationally relevant data streams—cellular mobility traces, payment terminal transaction logs, and Smart Retail nutrition records—capturing the behaviors of a large number of synthetically generated urban residents over a 12-week period. The framework integrates spatially explicit merchant selection using K-Dimensional (KD)-tree nearest-neighbor algorithms, temporally correlated anchor-based mobility simulation reflective of daily urban rhythms, and dietary-constraint filtering to preserve ecological validity in consumption patterns. In total, the system generates approximately 116 million mobility pings, 5.4 million transactions, and 1.9 million itemized purchases, yielding a reproducible benchmark for evaluating multimodal analytics, privacy-preserving computation, and secure IoT data-sharing protocols. To show the validity of this dataset, the underlying distributions of these residents were successfully validated against reported distributions in published research. We present preliminary uniqueness and cross-modal linkage indicators; comprehensive re-identification benchmarking against specific attack algorithms is planned as future work. This framework can be easily adapted to various scenarios of interest in Smart Cities and other IoT applications. By aligning methodological rigor with the operational needs of Smart City ecosystems, this work fills critical gaps in synthetic data generation for privacy-sensitive domains, including intelligent transportation systems, urban health informatics, and next-generation digital commerce infrastructures.

IoT↗

Demonstrating Reliable High Level Waste Slurry Sampling Techniques to Support Hanford Waste Processing

The Hanford Tank Operations Contractor (TOC) and the Hanford Waste Treatment and Immobilization Plant (WTP) contractor are both engaged in demonstrating mixing, sampling, and transfer system capability using simulated Hanford High-Level Waste (HL W) formulations. This work represents one of the remaining technical issues with the high-level waste treatment mission at Hanford. The TOC must demonstrate the ability to adequately mix and sample high-level waste feed to meet the WTP Waste Acceptance Criteria and Data Quality Objectives. The sampling method employed must support both TOC and WTP requirements. To facilitate information transfer between the two facilities the mixing and sampling demonstrations are led by the One System Integrated Project Team. The One System team, Waste Feed Delivery Mixing and Sampling Program, has developed a full scale sampling loop to demonstrate sampler capability. This paper discusses the full scale sampling loops ability to meet precision and accuracy requirements, including lessons learned during testing. Results of the testing showed that the Isolok(R) sampler chosen for implementation provides precise, repeatable results. The Isolok(R) sampler accuracy as tested did not meet test success criteria. Review of test data and the test platform following testing by a sampling expert identified several issues regarding the sampler used to provide reference material used to judge the Isolok's accuracy. Recommendations were made to obtain new data to evaluate the sampler's accuracy utilizing a reference sampler that follows good sampling protocol.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MO-G-17A-08: Applications of Quantitative PET/CT Imaging of Yttrium-90: A Tool for Improving Radioembolization

Purpose: Yttrium-90 (Y90) PET/CT post-treatment imaging of radioembolization has fostered significant interest from both the interventional radiology and nuclear medicine communities over the past few years. Recent literature has demonstrated high quantitative accuracy of Y90 PET at the activity concentrations common in radioembolization. However, few have explored methods in which this information can be clinically applied toward improving patient care. Methods: IRB approval and informed consent was obtained for over 35 Y90 post-treatment imaging studies, performed under 2 distinct protocols. In protocol 1, Y90 PET/CT provided quantitative post-treatment imaging, which was then converted into 3D maps of absorbed-dose. Both images and absorbed dose maps were used to manage patient care. In protocol 2, tumor absorbed-dose measurements from Y90 PET/CT were compared to known tumoricidal thresholds. If insufficient absorbed dose was delivered to the tumor, the patient would have an additional Y90 infusion the same day, providing truly patient-specific Y90 PET/CT based treatment-planning. Results: Y90 PET/CT allowed for a superior post-radioembolization evaluation of technical success compared with conventional Y90 bremsstrahlung SPECT. Due to the exceptional resolution of PET, a direct comparison between the distribution of radioembolization and pre-treatment planning intentions can be made. Further, quantification of tumor absorbed-dose directly from PET/CT imaging allows for the prediction of treatment efficacy based on a comparison with known tumoricidal thresholds. This immediate evaluation allowed treating physicians to consider additional or alternate therapies before discovering clinical failure weeks later. One protocol 2 patient was found to have a subtumoricidal absorbed dose following radioembolization. This patient received a same-day infusion of additional Y90 with identical catheter placement to the first infusion. A robust treatment response was seen on follow-up imaging. Conclusion: Y90 PET/CT produces quantifiable image sets, which can be transformed into 3D maps of absorbed dose. This information can be utilized to improve patient care. SIRTeX Medical, Surefire Medical.

60 APPLIED LIFE SCIENCES↗

Optimization of viral resuspension methods for carbon-rich soils along a permafrost thaw gradient

Permafrost stores approximately 50% of global soil carbon (C) in a frozen form; it is thawing rapidly under climate change, and little is known about viral communities in these soils or their roles in C cycling. In permafrost soils, microorganisms contribute significantly to C cycling, and characterizing them has recently been shown to improve prediction of ecosystem function. In other ecosystems, viruses have broad ecosystem and community impacts ranging from host cell mortality and organic matter cycling to horizontal gene transfer and reprogramming of core microbial metabolisms. Here we developed an optimized protocol to extract viruses from three types of high organic-matter peatland soils across a permafrost thaw gradient (palsa, moss-dominated bog, and sedge-dominated fen). Three separate experiments were used to evaluate the impact of chemical buffers, physical dispersion, storage conditions, and concentration and purification methods on viral yields. The most successful protocol, amended potassium citrate buffer with bead-beating or vortexing and BSA, yielded on average as much as 2-fold more virus-like particles (VLPs) g –1 of soil than other methods tested. All method combinations yielded VLPs g –1 of soil on the 10 8 order of magnitude across all three soil types. The different storage and concentration methods did not yield significantly more VLPs g –1 of soil among the soil types. In conclusion, this research provides much-needed guidelines for resuspending viruses from soils, specifically carbon-rich soils, paving the way for incorporating viruses into soil ecology studies.

54 ENVIRONMENTAL SCIENCES↗

Radiation Therapy Oncology Group Protocol 02-29: A Phase II Trial of Neoadjuvant Therapy With Concurrent Chemotherapy and Full-Dose Radiation Therapy Followed by Surgical Resection and Consolidative Therapy for Locally Advanced Non-small Cell Carcinoma of the Lung

Purpose: To evaluate mediastinal nodal clearance (MNC) rates after induction chemotherapy and concurrent, full-dose radiation therapy (RT) in a phase II trimodality trial (Radiation Therapy Oncology Group protocol 0229). Patients and Methods: Patients (n=57) with stage III non-small cell lung cancer (pathologically proven N2 or N3) were eligible. Induction chemotherapy consisted of weekly carboplatin (AUC = 2.0) and paclitaxel 50 mg/m{sup 2}. Concurrent RT was prescribed, with 50.4 Gy to the mediastinum and primary tumor and a boost of 10.8 Gy to all gross disease. The mediastinum was pathologically reassessed after completion of chemoradiation. The primary endpoint of the study was MNC, with secondary endpoints of 2-year overall survival and postoperative morbidity/mortality. Results: The grade 3/4 toxicities included hematologic 35%, gastrointestinal 14%, and pulmonary 23%. Forty-three patients (75%) were evaluable for the primary endpoint. Twenty-seven patients achieved the primary endpoint of MNC (63%). Thirty-seven patients underwent resection. There was a 14% incidence of grade 3 postoperative pulmonary complications and 1 30-day, postoperative grade 5 toxicity (3%). With a median follow-up of 24 months for all patients, the 2-year overall survival rate was 54%, and the 2-year progression-free survival rate was 33%. The 2-year overall survival rate was 75% for those who achieved nodal clearance, 52% for those with residual nodal disease, and 23% for those who were not evaluable for the primary endpoint (P=.0002). Conclusions: This multi-institutional trial confirms the ability of neoadjuvant concurrent chemoradiation with full-dose RT to sterilize known mediastinal nodal disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Factors for converting dose measured in polystyrene phantoms to dose reported in water phantoms for incident proton beams

Purpose: Previous dosimetry protocols allowed calibrations of proton beamline dose monitors to be performed in plastic phantoms. Nevertheless, dose determinations were referenced to absorbed dose-to-muscle or absorbed dose-to-water. The IAEA Code of Practice TRS 398 recommended that dose calibrations be performed with ionization chambers only in water phantoms because plastic-to-water dose conversion factors were not available with sufficient accuracy at the time of its writing. These factors are necessary, however, to evaluate the difference in doses delivered to patients if switching from calibration in plastic to a protocol that only allows calibration in water. Methods: This work measured polystyrene-to-water dose conversion factors for this purpose. Uncertainties in the results due to temperature, geometry, and chamber effects were minimized by using special experimental set-up procedures. The measurements were validated by Monte Carlo simulations. Results: At the peak of non-range-modulated beams, measured polystyrene-to-water factors ranged from 1.015 to 1.024 for beams with ranges from 36 to 315 mm. For beams with the same ranges and medium sized modulations, the factors ranged from 1.005 to 1.019. The measured results were used to generate tables of polystyrene-to-water dose conversion factors. Conclusions: The dose conversion factors can be used at clinical proton facilities to support beamline and patient specific dose per monitor unit calibrations performed in polystyrene phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

CST R9120-B 30x60 Media Pretreatment and Digestion Standard Development to Support Tank Closure Cesium Removal 1A (TCCR-1A) Operations

In support of continued operations of Savannah River Remediation’s (SRR) ion exchange process to remove radioactive cesium from Savannah River Site (SRS) dissolved saltcake, referred to as the Tank Closure Cesium Removal 1A process (TCCR-1A; containing the second set of at-tank ion exchange columns), SRNL was tasked with: 1) validating the field protocol planned for pretreating the crystalline silicotitanate (CST) ion exchange media to be used in the columns, 2) preparing CST media for use in in-tank batch contact testing, and 3) developing a digestion standard to verify complete CST dissolution prior to characterization following each in-tank batch contact test. A procedure (SRNL L29 Manual, ITS-0229) was developed previously in support of the TCCR Demonstration (which contained the first set of ion exchange columns) based on evaluations of a different CST production lot with a larger particle size range to document the protocol for pretreating CST utilizing conditions similar to what will be performed in the field.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-D-204-06: Dose and Image Quality Evaluation of a Low-Dose Slot-Scanning X-Ray System for Pediatric Orthopedic Studies

Purpose: Children in early teens with scoliosis require repeated radiographic exams over a number of years. The EOS (EOS imaging S.A., Paris, France) is a novel low-dose slot-scanning digital radiographic system designed to produce full-spine images of a free-standing patient. The radiation dose and image quality characteristics of the EOS were evaluated relative to those of a Computed Radiography (CR) system for scoliosis imaging. Methods: For dose evaluation, a full-torso anthropomorphic phantom was scanned five times using the default standard clinical protocols for both the EOS and a CR system, which include both posteroanterior and lateral full-spine views. Optically stimulated luminescent dosimeters (OSLDs), also known as nanoDots™ (Landauer, Inc., Glenwood, IL), were placed on the phantom’s surface to measure entrance skin dose. To assess image quality, MTF curves were generated from sampling the noise levels within the high-contrast regions of a line-pair phantom. Vertical and horizontal distortions were measured for the square line-pair phantom with the EOS system to evaluate the effects of geometric magnification and misalignment with the indicated imaging plane. Results: The entrance skin dose was measured to be 0.4 to 1.1 mGy for the EOS, and 0.7 to 3.6 mGy for the CR study. MTF comparison shows that CR greatly outperforms the EOS, despite both systems having a limiting resolution at 1.8 line-pairs per mm. Vertical distortion was unaffected by phantom positioning, because of the EOS slot-scanning geometry. Horizontal distortion increased linearly with miscentering distance. Conclusion: The EOS system resulted in approximately 70% lower radiation dose than CR for full-spine images. Image quality was found to be inferior to CR. Further investigation is required to see if EOS system is an acceptable modality for performing clinically diagnostic scoliosis examinations.

60 APPLIED LIFE SCIENCES↗

A Review of the Evaluation of Building Energy Code Compliance in the United States

Building energy codes are essential tools for achieving energy efficiency in buildings. However, the full energy savings potential of these codes can only be realized if buildings are constructed in compliance with them. Therefore, evaluating building energy code compliance is crucial in bridging the gap between the energy efficiency requirements set by energy codes and the actualized energy savings achieved. An energy code compliance evaluation serves as a mechanism to assess construction practices, evaluate the effectiveness of code enforcement, identify gaps in compliance, and guide strategies for improvement through training and education. Conducting code compliance evaluation activities involves field studies that require careful design and significant resources. Historically, more emphasis has been placed on developing and adopting building energy codes, while efforts to evaluate compliance have been relatively limited and lacking consistent approaches. The passage of the 2009 American Recovery and Reinvestment Act (ARRA), which mandated that states create plans for achieving 90% compliance within eight years, stimulated the need for an energy code compliance evaluation. As a result, federal, state, and local governments, and utilities have invested in the development of methodologies and tools for code compliance evaluation studies. This paper reviews the code compliance evaluation studies conducted in the United States over the past three decades. It describes and compares the methodologies and metrics used to assess building energy code compliance, summarizes the general elements and steps involved in the evaluation process, and discusses common issues in these studies. Over time, code compliance evaluation methodologies have evolved from isolated development within individual states, regions, and utilities, to widely accepted protocols applicable across different states and local jurisdictions. There has been a transition in compliance metrics, shifting from historical compliance rates to energy-consumption-oriented approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-F-T-19: The Consistency Dosimetric Analysis of the Accelerated Breast Brachytherapy

Purpose: To assess the best approach in accept a treatment plan for APBI Savi patients. Should we run a treatment verification test prior to delivering it to the patient? Should we check each CT scan in regards to the initial one in dosimetrical terms? Do we need deformable registration and adaptive planning for each fraction? These are the questions we want to answer running a dosimetric analysis of the dose variances for APBI treatments who receive 10 fractions and no re-planning has been done being considered unnecessary with today’s means of assessment. Methods: A retrospective analysis of 30 patients treated with SAVI applicators were considered for this study. The CT scans taken before each treatment were imported in the treatment planning system and registered with the initial CT scan. The images were fused together with respective to the applicator, using landmark registration. Dosimetric evaluations were performed. Dose received by skin, ribs and PTV on CT images with respect to the initial treatment plan were recorded including maximum, average and minimum dose Results: All the structures displayed changes in volume over the 10 fractions of treatment. The cavities reduction in volume was considerable with a maximum reduction of over 10%. The PTV-eval is covered better due to this fact while the critical organs manifest an increase in the total and maximum dose delivered. Ribs and skin surface that are required by B39 protocol to be monitored can acquire maximum doses of 20% to 30% respectively. Conclusion: A dosimetric evaluation prior to the initial treatment and prior to each of the 10 fractions is proven to be necessary. Deformable registration and adaptive planning have to be studied more and eventually implemented for every patient who received more than one fraction of any type of brachytherapy treatment. Immobilization ad localization methods must be improved and studied further.

60 APPLIED LIFE SCIENCES↗

Development of a dynamic quality assurance testing protocol for multisite clinical trial DCE-CT accreditation

Purpose: Credentialing can have an impact on whether or not a clinical trial produces useful quality data that is comparable between various institutions and scanners. With the recent increase of dynamic contrast enhanced-computed tomography (DCE-CT) usage as a companion biomarker in clinical trials, effective quality assurance, and control methods are required to ensure there is minimal deviation in the results between different scanners and protocols at various institutions. This paper attempts to address this problem by utilizing a dynamic flow imaging phantom to develop and evaluate a DCE-CT quality assurance (QA) protocol.Methods: A previously designed flow phantom, capable of producing predictable and reproducible time concentration curves from contrast injection was fully validated and then utilized to design a DCE-CT QA protocol. The QA protocol involved a set of quantitative metrics including injected and total mass error, as well as goodness of fit comparison to the known truth concentration curves. An additional region of interest (ROI) sensitivity analysis was also developed to provide additional details on intrascanner variability and determine appropriate ROI sizes for quantitative analysis. Both the QA protocol and ROI sensitivity analysis were utilized to test variations in DCE-CT results using different imaging parameters (tube voltage and current) as well as alternate reconstruction methods and imaging techniques. The developed QA protocol and ROI sensitivity analysis was then applied at three institutions that were part of clinical trial involving DCE-CT and results were compared.Results: The inherent specificity of robustness of the phantom was determined through calculation of the total intraday variability and determined to be less than 2.2 ± 1.1% (total calculated output contrast mass error) with a goodness of fit (R{sup 2}) of greater than 0.99 ± 0.0035 (n= 10). The DCE-CT QA protocol was capable of detecting significant deviations from the expected phantom result when scanning at low mAs and low kVp in terms of quantitative metrics (Injected Mass Error 15.4%), goodness of fit (R{sup 2}) of 0.91, and ROI sensitivity (increase in minimum input function ROI radius by 146 ± 86%). These tests also confirmed that the ASIR reconstruction process was beneficial in reducing noise without substantially increasing partial volume effects and that vendor specific modes (e.g., axial shuttle) did not significantly affect the phantom results. The phantom and QA protocol were finally able to quickly (<90 min) and successfully validate the DCE-CT imaging protocol utilized at the three separate institutions of a multicenter clinical trial; thereby enhancing the confidence in the patient data collected.Conclusions: A DCE QA protocol was developed that, in combination with a dynamic multimodality flow phantom, allows the intrascanner variability to be separated from other sources of variability such as the impact of injection protocol and ROI selection. This provides a valuable resource that can be utilized at various clinical trial institutions to test conformance with imaging protocols and accuracy requirements as well as ensure that the scanners are performing as expected for dynamic scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Multi-Site Networked Hardware-in-Loop Platform for Evaluation of Interoperability and Distributed Intelligence at Grid-Edge

Electric power systems have experienced large increases in the number of intelligent, connected and controllable devices being deployed, leading to a high degree of distributed intelligence at the grid-edge. These devices, both utility-owned and consumer-owned, include but are not limited to: renewable generation sources, energy storage, remote switches, voltage regulators, and smart controllable loads such as electric vehicles. These new devices provide significant potential for increased operational flexibility that can be leveraged to achieve system reconfiguration, resiliency improvements, power quality improvements, and distribution system automation. However, there are two significant challenges that must be addressed before these assets can be leveraged for operations: interoperability and system level validation prior to deployment. Because of the complexity of distributed control systems, and their interactions with legacy centralized controls, a purely simulations-based approach for pre-deployment validation is not sufficient. It requires hardware-in-loop testing to emulate the operational hardware devices and evaluate their performance. Additionally, securely integrating multiple test facilities at utility operators and vendors might enable rapid scale-up of evaluation platforms, and remove the need for multiple expensive standalone installations. Presented in this paper, is the development of a multi-site evaluation platform that employs Advanced Distribution Management Systems (ADMS), distributed control devices, real-time hardware-in-loop assets, secure communication links, and protocol adapters. This platform uses standards-based approaches and open-source tools, and hence can serve as a template for other researchers and institutions to implement their multi-site evaluation frameworks for pre-deployment testing.

Essakiappan, Somasundaram↗

Integration and evaluation of a needle-positioning robot with volumetric microcomputed tomography image guidance for small animal stereotactic interventions

Purpose: Preclinical research protocols often require insertion of needles to specific targets within small animal brains. To target biologically relevant locations in rodent brains more effectively, a robotic device has been developed that is capable of positioning a needle along oblique trajectories through a single burr hole in the skull under volumetric microcomputed tomography (micro-CT) guidance. Methods: An x-ray compatible stereotactic frame secures the head throughout the procedure using a bite bar, nose clamp, and ear bars. CT-to-robot registration enables structures identified in the image to be mapped to physical coordinates in the brain. Registration is accomplished by injecting a barium sulfate contrast agent as the robot withdraws the needle from predefined points in a phantom. Registration accuracy is affected by the robot-positioning error and is assessed by measuring the surface registration error for the fiducial and target needle tracks (FRE and TRE). This system was demonstrated in situ by injecting 200 {mu}m tungsten beads into rat brains along oblique trajectories through a single burr hole on the top of the skull under micro-CT image guidance. Postintervention micro-CT images of each skull were registered with preintervention high-field magnetic resonance images of the brain to infer the anatomical locations of the beads. Results: Registration using four fiducial needle tracks and one target track produced a FRE and a TRE of 96 and 210 {mu}m, respectively. Evaluation with tissue-mimicking gelatin phantoms showed that locations could be targeted with a mean error of 154{+-}113 {mu}m. Conclusions: The integration of a robotic needle-positioning device with volumetric micro-CT image guidance should increase the accuracy and reduce the invasiveness of stereotactic needle interventions in small animals.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase Transition Enthalpy Measurements of Organic and Organometallic Compounds. Sublimation, Vaporization and Fusion Enthalpies From 1880 to 2015. Part 1. C{sub 1} − C{sub 10}

A compendium of phase change enthalpies published in 2010 is updated to include the period 1880–2015. Phase change enthalpies including fusion, vaporization, and sublimation enthalpies are included for organic, organometallic, and a few inorganic compounds. Part 1 of this compendium includes organic compounds from C{sub 1} to C{sub 10}. Part 2 of this compendium, to be published separately, will include organic and organometallic compounds from C{sub 11} to C{sub 192}. Sufficient data are presently available to permit thermodynamic cycles to be constructed as an independent means of evaluating the reliability of the data. Temperature adjustments of phase change enthalpies from the temperature of measurement to the standard reference temperature, T = 298.15 K, and a protocol for doing so are briefly discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The development of methods for primary mast cells in vitro and ex vivo: An historical review

Highlights: • Mast cells form a first-line defense of immune system against various challenges. • Over the past few decades, technologies for acquiring mast cells have been continually optimized. • The advantages and applicability of diverse mast cell models evaluated. • It is important to choose a proper cell source for mast cell-related experiments. Mast cells (MCs) are tissue-based stationary effector cells that form the immune system's first-line defense against various challenges. They are developed from the bone marrow-derived progenitors to complete their differentiation and maturation in the tissues where they eventually establish residence. MCs have been implicated in many diseases, such as allergy, parasitic infection, and neoplastic disorders. Immortalized MC lines, such as RBL-2H3, HMC-1, and LAD-2, are useful for investigating the biological functions of MC only to some extents due to the restriction of degranulation evaluation, in vivo injection and other factors. Over the past few decades, technologies for acquiring primarily MCs have been continually optimized, and novel protocols have been proposed. However, no relevant publications have analyzed and summarized these techniques. In this review, the classical approaches for extracting MCs are generalized, and new methods with potential values are introduced. We also evaluate the advantages and applicability of diverse MC models. Since MCs exhibit substantial plasticity and functional diversity due to different origins, it is both necessary and urgent to select a reliable and suitable source of MCs for a particular study.

60 APPLIED LIFE SCIENCES↗

PET optimization for improved assessment and accurate quantification of {sup 90}Y-microsphere biodistribution after radioembolization

Purpose: {sup 90}Y-microspheres are widely used for the radioembolization of metastatic liver cancer or hepatocellular carcinoma and there is a growing interest for imaging {sup 90}Y-microspheres with PET. The aim of this study is to evaluate the performance of a current generation PET/CT scanner for {sup 90}Y imaging and to optimize the PET protocol to improve the assessment and the quantification of {sup 90}Y-microsphere biodistribution after radioembolization. Methods: Data were acquired on a Biograph mCT-TrueV scanner with time of flight (TOF) and point spread function (PSF) modeling. Spatial resolution was measured with a{sup 90}Y point source. Sensitivity was evaluated using the NEMA 70 cm line source filled with {sup 90}Y. To evaluate the count rate performance, {sup 90}Y vials with activity ranging from 3.64 to 0.035 GBq were measured in the center of the field of view (CFOV). The energy spectrum was evaluated. Image quality with different reconstructions was studied using the Jaszczak phantom containing six hollow spheres (diameters: 31.3, 28.1, 21.8, 16.1, 13.3, and 10.5 mm), filled with a 207 kBq/ml {sup 90}Y concentration and a 5:1 sphere-to-background ratio. Acquisition time was adjusted to simulate the quality of a realistic clinical PET acquisition of a patient treated with SIR-Spheres{sup ®}. The developed methodology was applied to ten patients after SIR-Spheres{sup ®} treatment acquiring a 10 min per bed PET. Results: The energy spectrum showed the{sup 90}Y bremsstrahlung radiation. The {sup 90}Y transverse resolution, with filtered backprojection reconstruction, was 4.5 mm in the CFOV and degraded to 5.0 mm at 10 cm off-axis. {sup 90}Y absolute sensitivity was 0.40 kcps/MBq in the center of the field of view. Tendency of true and random rates as a function of the {sup 90}Y activity could be accurately described using linear and quadratic models, respectively. Phantom studies demonstrated that, due to low count statistics in {sup 90}Y PET acquisition, the optimal parameters for the standard OSEM+PSF reconstruction were only one iteration and a postreconstruction filter of 6 mm FWHM, for both TOF and non-TOF reconstructions. Moreover, when TOF is included, the signal to noise ratio increased and visibility achieved 100% by the experienced observers and 93.3% according to the Rose model of statistical detection. In 50% of patients, TOF allowed the visualization of {sup 90}Y radioembolized lesions not seen without TOF, confirming phantom results. Liver activity was accurately quantified, with no significant differences between reconstructed and actual delivered activity to the whole-liver [mean relative difference (10.2 ± 14.7)%]. Conclusions: Qualitative and quantitative{sup 90}Y PET imaging improved with the introduction of TOF in a PET/CT scanner, thereby allowing the visualization of microsphere deposition in lesions not visible in non-TOF images. This technique accurately quantifies the total activity delivered to the liver during radioembolization with {sup 90}Y-microspheres and allows dose estimation.

60 APPLIED LIFE SCIENCES↗

Weighted active space protocol for multireference machine-learned potentials

Multireference methods such as multiconfiguration pair-density functional theory accurately capture electronic correlation in systems with strong multiconfigurational character, but their cost precludes direct use in molecular dynamics. Combining these methods with machine-learned interatomic potentials (MLPs) can extend their reach. However, the sensitivity of multireference calculations to the choice of the active space complicates the consistent evaluation of energies and gradients across structurally diverse nuclear configurations. To overcome this limitation, we introduce the weighted active space protocol (WASP), a systematic approach to assign a consistent active space for a given system across uncorrelated configurations. By integrating WASP with MLPs and enhanced sampling techniques, we propose a data-efficient active learning cycle that enables the training of an MLP on multireference data. We demonstrated the approach on the TiC + -catalyzed C–H activation of methane, a reaction that poses challenges for Kohn–Sham density functional theory due to its significant multireference character. This framework enables accurate and efficient modeling of catalytic dynamics, establishing a paradigm for simulating complex reactive processes beyond the limits of conventional electronic-structure methods.

enhanced sampling↗