Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Early season prediction of within-field crop yield variability by assimilating CubeSat data into a crop model

Accurate early season predictions of crop yield at the within-field scale can be used to address a range of crop production, management, and precision agricultural challenges. While the remote sensing of within-field insights has been a research goal for many years, it is only recently that observations with the required spatio-temporal resolutions, together with efficient assimilation methods to integrate these into modeling frameworks, have become available to advance yield prediction efforts. Here we explore a yield prediction approach that combines daily high-resolution CubeSat imagery with the APSIM crop model. The approach employs APSIM to train a linear regression that relates simulated yield to simulated leaf area index (LAI). That relationship is then used to identify the optimal regression date at which the LAI provides the best prediction of yield: in this case, approximately 14 weeks prior to harvest. Instead of applying the regression on satellite imagery that is coincident, or closest to, the regression date, our method implements a particle filter that integrates CubeSat-based LAI into APSIM to provide end-of-season high-resolution (3 m) yield maps weeks before the optimal regression date. The approach is demonstrated on a rainfed maize field located in Nebraska, USA, where suitable collections of both imagery and in-situ data were available for assessment. The procedure does not require in-field data to calibrate the regression model, with results showing that even with a single assimilation step, it is possible to provide yield estimates with good accuracy up to 21 days before the optimal regression date. Yield spatial variability was reproduced reasonably well, with a strong correlation to independently collected measurements (R 2 = 0.73 and rRMSE = 12%). When the field averaged yield was compared, our approach reduced yield prediction error from 1 Mg/ha (control case based on a calibrated APSIM model), to 0.5 Mg/ha (using satellite imagery alone), and then to 0.2 Mg/ha (results with assimilation up to three weeks prior to the optimal regression date). Such a capacity to provide spatially explicit yield predictions early in the season has considerable potential to enhance digital agricultural goals and improve end-of-season yield predictions.

54 ENVIRONMENTAL SCIENCES↗

Detector Development for the MARE Neutrino Experiment

The MARE experiment is designed to measure the mass of the neutrino with sub-eV sensitivity by measuring the beta decay of {sup 187}Re with cryogenic microcalorimeters. A preliminary analysis shows that, to achieve the necessary statistics, between 10,000 and 50,000 detectors are likely necessary. We have fabricated and characterized Iridium transition edge sensors with high reproducibility and uniformity for such a large scale experiment. We have also started a full scale simulation of the experimental setup for MARE, including thermalization in the absorber, detector response, and optimum filter analysis, to understand the issues related to reaching a sub-eV sensitivity and to optimize the design of the MARE experiment. We present our characterization of the Ir devices, including reproducibility, uniformity, and sensitivity, and we discuss the implementation and capabilities of our full scale simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A digitizer based compact digital spectrometer for ion beam analysis using field programmable gate arrays and various energy algorithms

We report on the implementation of a compact multi-detector fully digital spectrometer and data acquisition system at a nuclear microprobe for ion beam analysis and imaging. The spectrometer design allows for system scalability with no restriction on the number of detectors. It consists of four-channel high-speed digitizer modules for detector signal acquisition and one low-speed digital-to-analog converter (DAC) module with two DAC channels and additional general purpose inputs/outputs to control ion beam scanning and data acquisition. Each digitizer module of the spectrometer provides its own Field Programmable Gate Array (FPGA) as digital signal processing unit to analyze detector signals as well as to synchronize the ion beam position in hard real-time. With the customized FPGA designs for all modules, all calculation intensive tasks are executed inside the modules, which reduces significantly the data stream to and CPU load on the control computer. To achieve an optimal energy resolution for all detector/preamplifier pulse shape characteristics, a user-definable infinite impulse response filter with high throughput for energy determination was implemented. The new spectrometer has an online data analysis feature, a compact size, and is able to process any type of detector signals such as particle induced x-ray emission, Rutherford backscattering spectrometry, or scanning transmission ion microscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Control Algorithms for Dual-wavefront Sensor Single-conjugate Adaptive Optics

High-contrast imaging systems using active control with adaptive optics (AO) are often limited by non-common path (NCP) aberrations that are seen only at the final science image. AO systems employing focal-plane wavefront sensors (FP-WFSs) are able to simultaneously correct NCP aberrations and measure science images, but they typically require a second stage of control that adds system cost and complexity. We present control algorithms to augment AO systems with FP-WFSs within their existing control setup. We demonstrate inter-arm NCP aberration transfer can be mitigated through temporal filtering, present frequency- and time-domain validation of controller stability and performance, and discuss the optimality of the chosen controllers. This work will enable the development, testing, and installation of FP-WFS technologies for direct imaging of exoplanets.

79 ASTRONOMY AND ASTROPHYSICS↗

Neuro-Spark: A Submicrosecond Spiking Neural Networks Architecture for In-Sensor Filtering

Neuro-Spark, which is a new neuromorphic architecture with a field-programmable gate array (FPGA) implementation for ultrafast spiking neural network (SNN) inference at the edge, facilitates smart-pixel in-sensor filtering for high-energy physics experiments at the Large Hadron Collider (LHC). Utilizing the evolutionary optimization for neuromorphic systems (EONS) training method, we generate compact SNN models with 91% signal efficiency, akin to convolutional neural networks but with half the parameters. However, deploying near the detector poses a challenge because the SNN must handle a sustained input data rate exceeding 1013 GB/s. To overcome this, we propose a novel hardware architecture that uses high-level synthesis to construct a tuned architecture for the EONS-trained SNN. In addition to the analysis and validation with an AMD Xilinx Artix-A7 FPGA, our solution consumes only ç24% of FPGA LUT and flipflops. We also introduce an innovative quantization method that reduces FPGA resource utilization by ç15% without compromising accuracy. Our FPGA implementation achieves computing latency of ç10 ns for smart-pixel application inference on an edge FPGA.

Miniskar, Narasinga Rao↗

LIBS Spectral Data for a Mixed Actinide Fuel Pellet Containing Uranium, Plutonium, Neptunium and Americium (V.1)

Laser-induced breakdown spectroscopy (LIBS) was used to analyze a mixed actinide fuel pellet containing 75% UO 2 /20% PuO 2 /3% AmO 2 /2% NpO 2 . The preliminary data shown here is the first report of LIBS analysis of a mixed actinide fuel pellet, to the authors knowledge. The LIBS spectral data was acquired in a plutonium facility at Los Alamos National Laboratory where the sample was contained within a glove box. The initial installation of the glove box was not intended for complete ultraviolet (UV), visible (VIS) and near infrared (NIR) transmission, therefore the LIBS spectrum is truncated in the UV and NIR regions due to the optical transmission of the window port and filters that were installed. The optical collection of the emission from the LIBS plasma will be optimized in the future. However, the preliminary LIBS data acquired is worth reporting due to the uniqueness of the sample and spectral data. The analysis of several actinides in the presence of each other is an important feature of this analysis since traditional methods must chemically separate uranium, plutonium, neptunium, and americium prior to analysis. Due to the historic nature of the sample fuel pellet analyzed, the provided sample composition of 75% UO 2 /20% PuO 2 /3% AmO 2 /2% NpO 2 cannot be confirm without further analytical processing. Uranium, plutonium, and americium emission lines were abundant and easily assigned while neptunium was more difficult to identify. There may be several reasons for this observation, other than knowing the exact sample composition of the fuel pellet. First, the atomic emission wavelength resources for neptunium are limited and such techniques as hollow cathode discharge lamp have different dynamics than the plasma used in LIBS which results in different emission spectra. Secondly, due to the complex sample of four actinide elements, which all have very dense electronic energy levels, there may be reactions and interactions occurring within the plasma, such as collisional energy transfer, that might be a factor in the reduction in neptunium emission lines. Neptunium has to be analyzed alone using LIBS to further understand the dynamics that may be occurring in the plasma of the mixed actinide fuel pellet sample. The LIBS data suggests that the emission spectrum for the mixed actinide fuel pellet is not simply the sum of the emission spectra of the pure samples but is dependent on the species present in the plasma and the interactions and reactions that occur within the plasma. Finally, many of the neptunium lines are in the near infrared region which is drastically reduced in intensity by the current optical setup and possibly the sensitivity of the emission detector in the spectral region. Once the optics are replaced and the optical collection system is modified and optimized, the probability of observing emission lines for neptunium might be increased significantly. The mixed actinide fuel pellet was analyzed under the experimental conditions listed in Table 1. The LIBS spectra of the fuel pellet are shown in Figures 1-49. The spectra are labeled with the observed wavelength and atomic species (both neutral (I) and ionic (II)). Table 2 is a complete list of the observed and literature based emission wavelengths. The literature wavelengths have references including NIST Atomic Spectra Database (NIST), B.A. Palmer et al. 'An Atlas of Uranium Emission Intensities in a Hollow Cathode Discharge' taken at the Kitt Peak National Observatory (KPNO), R.L. Kurucz 1995 Atomic Line Data from the Smithsonian Astrophysical Observatory (SAO), J. Blaise et al. 'The Atomic Spectrum of Plutonium' from Argonne National Laboratory (BFG), and M. Fred and F.S. Tomkins, 'Preliminary Term Analysis of Am I and Am II Spectra' (FT). The dash (-) shown under Ionic State indicates that the ionic state of the transition was not available. In the spectra, the dash (-) is replaced with a question mark (?). Peaks that are not assigned are most likely real features and not noise but cannot be confidently assigned to a transition without further investigation. Several peaks have multiple assignments due to limited resolution of the spectrometer used (20,000, $\lambda$/$\Delta$$\lambda$) and without the availability, at this point in time, of pure PuO 2 , AmO 2 , and NpO 2 to confirm the identity of the peaks. A different spectrometer was used in the plutonium facility to collect the mixed actinide fuel pellet data (Echelle 3000) than the DUO 2 , ThO 2 and uranium ore previously reported (Echelle 4000) which accounts for the slight shift in the observed wavelength of the uranium emission lines.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparing Outdoor to Indoor Performance for Bifacial Modules Affected by Polarization-Type Potential-Induced Degradation

Bifacial photovoltaic (PV) modules have the advantage of using light reflected off of the ground to contribute to power production. Predicting the energy gain is challenging and requires complex models to do so accurately. Often, module degradation over time is neglected in models for the sake of simplicity or is underestimated. Comparing outdoor and indoor current–voltage (I–V) performance for bifacial modules is more challenging than for monofacial modules, as there are additional variables to consider such as rear albedo non-uniformity, cell mismatch, and their effects on temperature. This challenge is compounded when heterogeneous degradation modes occur, such as polarization-type potential-induced degradation (PID-p). To examine the effects of PID-p on I–V predictions using an empirical data-driven approach, 16 bifacial PERC modules are installed outdoors on racks with different albedo conditions. A subset is exposed to high-voltage biases of −1500 V or +1500 V. Outdoor data are traced at irradiance ranges of 150–250 W/m 2 , 500–600 W/m 2 , and 900–1000 W/m 2 . These curves are corrected using control module temperature, wire resistivity, and module resistance measured indoors. We examine several methods to transform indoor I–V curves to accurately, and more simply than existing methods, approximate outdoor performance for bifacial modules without and with varying levels of PID-p degradation. This way, bifacial performance modeling can be more accessible and informed by fielded, degraded modules. Distributions of percent errors between indoor and outdoor performance parameters and Mean Absolute Percent Errors (MAPEs) are used to assess method quality. Results including low-irradiance data (150–250 W/m 2 ) are discussed but are filtered for quantifying method quality as these data introduce substantial errors. The method with the most optimal tradeoff between low MAPE and analysis simplicity involves measuring the front side of a module indoors at an irradiance equal to plane-of-array irradiance plus the product of module bifaciality and albedo irradiance. This method gives MAPE values of 1–6.5% for non-degraded and 1.6–5.9% for PID-p degraded module performance.

14 SOLAR ENERGY↗

Preliminary Design of Pinhole camera for NSLS-II Project.

The NSLS-II Light Source being built at Brookhaven National Laboratory is expected to provide very small emittances and electron beam sizes. High resolution imaging systems are required in order to provide robust measurements. The pinhole camera will utilize 6-fold magnification with a pinhole placed inside a crotch absorber. The pinhole is protected from high power synchrotron radiation with a filter made of refractory metal. In this paper we provide resolution analyses, heat load calculations, and optimization details for the NSLS-II pinhole camera, including beamline design.

43 PARTICLE ACCELERATORS↗

Optimization-Based Fast-Frequency Estimation and Control of Low-Inertia Microgrids

The lack of inertial response from non-synchronous, inverter-based generation in microgrids makes the power system vulnerable to a large rate of change of frequency (ROCOF) and frequency excursions. Energy storage systems (ESSs) can be utilized to provide fast-frequency support to prevent such large excursions in the system. However, fast-frequency support is a power-intensive application that has a significant impact on the ESS lifetime. In this paper, a framework that allows the ESS operator to provide fast-frequency support as a service is proposed. The framework maintains the desired quality-of-service (limiting the ROCOF and frequency) while taking into account the ESS lifetime and physical limits. The framework utilizes moving horizon estimation (MHE) to estimate the frequency deviation and ROCOF from noisy phase-locked loop (PLL) measurements. These estimates are employed by a model predictive control (MPC) algorithm that computes control actions by solving a finite-horizon, online optimization problem. Additionally, this approach avoids oscillatory behavior induced by delays that are common when using low-pass filters as with traditional derivative-based (virtual inertia) controllers. MATLAB/Simulink simulations on a test system from Cordova, Alaska, show the effectiveness of the MHE-MPC approach to reduce frequency deviations and ROCOF of a low-inertia microgrid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Optimal Power Control Strategy for Grid-Following Inverters in a Synchronous Frame

This work proposes a power control strategy based on the linear quadratic regulator with optimal reference tracking (LQR-ORT) for a three-phase inverter-based generator (IBG) using an LCL filter. The use of an LQR-ORT controller increases robustness margins and reduces the quadratic value of the power error and control inputs during transient response. A model in a synchronous reference frame that integrates power sharing and voltage–current (V–I) dynamics is also proposed. This model allows for analyzing closed-loop eigenvalue location and robustness margins. The proposed controller was compared against a classical droop approach using proportional-resonant controllers for the inner loops. Mathematical analysis and hardware-in-the-loop (HIL) experiments under variations in the LCL filter components demonstrate fulfillment of robustness and performance bounds of the LQR-ORT controller. Experimental results demonstrate accuracy of the proposed model and the effectiveness of the LQR-ORT controller in improving transient response, robustness, and power decoupling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TH-AB-209-01: Making Benchtop X-Ray Fluorescence Computed Tomography (XFCT) Practical for in Vivo Imaging by Integration of a Dedicated High-Performance X-Ray Source in Conjunction with Micro-CT Functionality

Purpose: To make benchtop x-ray fluorescence computed tomography (XFCT) practical for routine preclinical imaging tasks with gold nanoparticles (GNPs) by deploying, integrating, and characterizing a dedicated high-performance x-ray source and addition of simultaneous micro-CT functionality. Methods: Considerable research effort is currently under way to develop a polychromatic benchtop cone-beam XFCT system capable of imaging GNPs by stimulation and detection of gold K-shell x-ray fluorescence (XRF) photons. Recently, an ad hoc high-power x-ray source was incorporated and used to image the biodistribution of GNPs within a mouse, postmortem. In the current work, a dedicated x-ray source system featuring a liquid-cooled tungsten-target x-ray tube (max 160 kVp, ∼3 kW power) was deployed. The source was operated at 125 kVp, 24 mA. The tube’s compact dimensions allowed greater flexibility for optimizing both the irradiation and detection geometries. Incident x-rays were shaped by a conical collimator and filtered by 2 mm of tin. A compact “OEM” cadmium-telluride x-ray detector was implemented for detecting XRF/scatter spectra. Additionally, a flat panel detector was installed to allow simultaneous transmission CT imaging. The performance of the system was characterized by determining the detection limit (10-second acquisition time) for inserts filled with water/GNPs at various concentrations (0 and 0.010–1.0 wt%) and embedded in a small-animal-sized phantom. The phantom was loaded with 0.5, 0.3, and 0.1 wt% inserts and imaged using XFCT and simultaneous micro-CT. Results: An unprecedented detection limit of 0.030 wt% was experimentally demonstrated, with a 33% reduction in acquisition time. The reconstructed XFCT image accurately localized the imaging inserts. Micro-CT imaging did not provide enough contrast to distinguish imaging inserts from the phantom under the current conditions. Conclusion: The system is immediately capable of in vivo preclinical XFCT imaging with GNPs. Micro-CT imaging will require optimization of irradiation parameters to improve contrast. Supported by NIH/NCI grant R01CA155446; This investigation was supported by NIH/NCI grant R01CA155446.

60 APPLIED LIFE SCIENCES↗

A new efficient grain growth model using a random Gaussian-sampled mode filter

This paper presents the use of a Gaussian neighborhood mode filter for predicting grain growth in a manner similar to the solutions obtained by a Monte Carlo Potts model. This flexible grain growth model can quickly utilize modern, computationally optimized data science strategies on graphics processing units to simulate grain growth up to 100 times faster than the state-of-the-art, publicly available Monte Carlo Potts model. We show that, given the correct neighborhood, the mode filter can replicate normal grain growth in two or three dimensions. In addition, the paper briefly demonstrates the ability to model limited anisotropic in grain boundary energy and mobility. Anisotropic grain boundary energy is modeled by defining a weighted mode filter operation. Anisotropic grain boundary mobility is modeled by scaling and orienting the Gaussian neighborhood in a particular direction.

Anisotropy↗

Challenges and Solutions for Fast Neutron Irradiation of Bulk Material Specimens

Reactor developers continue to recognize opportunities for further enhancing fast spectrum reactor designs with advanced core materials, but all the material test reactors currently available to the United States are thermal spectrum designs. Fortunately, the Advanced Test Reactor and High Flux Isotope Reactor are versatile high flux facilities where spectral modification strategies can be used to reduce undesirable thermal neutron capture transmutation damage and augment fast flux delivered to specimens. New opportunities to leverage high flux regions and specially designed fast flux boosting experiment configurations can be used to achieve meaningful fast fluences on large specimens in ATR. New optimization potentials can be employed to achieve even higher fluences, albeit for smaller specimens, using thermal neutron filters in HFIR test positions. These capabilities, while not true fast reactors, can provide highly relevant environments for researchers needing to study the effects of fast neutron damage in bulk material specimens.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Accurate prediction of mega-electron-volt electron beam properties from UED using machine learning

To harness the full potential of the ultrafast electron diffraction (UED) and microscopy (UEM), we must know accurately the electron beam properties, such as emittance, energy spread, spatial-pointing jitter, and shot-to-shot energy fluctuation. Owing to the inherent fluctuations in UED/UEM instruments, obtaining such detailed knowledge requires real-time characterization of the beam properties for each electron bunch. While diagnostics of these properties exist, they are often invasive, and many of them cannot operate at a high repetition rate. Here, we present a technique to overcome such limitations. Employing a machine learning (ML) strategy, we can accurately predict electron beam properties for every shot using only parameters that are easily recorded at high repetition rate by the detector while the experiments are ongoing, by training a model on a small set of fully diagnosed bunches. Applying ML as real-time noninvasive diagnostics could enable some new capabilities, e.g., online optimization of the long-term stability and fine single-shot quality of the electron beam, filtering the events and making online corrections of the data for time-resolved UED, otherwise impossible. This opens the possibility of fully realizing the potential of high repetition rate UED and UEM for life science and condensed matter physics applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Astrophysics & cosmology from line intensity mapping vs galaxy surveys

Line intensity mapping (LIM) proposes to efficiently observe distant faint galaxies and map the matter density field at high redshift. Building upon the formalism in a companion paper, we first highlight the degeneracies between cosmology and astrophysics in LIM. We discuss what can be constrained from measurements of the mean intensity and redshift-space power spectra. With a sufficient spectral resolution, the large-scale redshift-space distortions of the 2-halo term can be measured, helping to break the degeneracy between bias and mean intensity. With a higher spectral resolution, measuring the small-scale redshift-space distortions disentangles the 1-halo and shot noise terms. Additionally, cross-correlations with external galaxy catalogs or lensing surveys further break degeneracies. We derive requirements for experiments similar to SPHEREx, HETDEX, CDIM, COMAP and CONCERTO. We then revisit the question of the optimality of the LIM observables, compared to galaxy detection, for astrophysics and cosmology. We use a matched filter to compute the luminosity detection threshold for individual sources. We show that LIM contains information about galaxies too faint to detect, in the high-noise or high-confusion regimes. We quantify the sparsity and clustering bias of the detected sources and compare them to LIM, showing in which cases LIM is a better tracer of the matter density. We extend previous work by answering these questions as a function of Fourier scale, including for the first time the effect of cosmic variance, pixel-to-pixel correlations, luminosity-dependent clustering bias and redshift-space distortions.

79 ASTRONOMY AND ASTROPHYSICS↗

Artificial Intelligence Designer of Materials and Processes for Advanced Power Generation

In this presentation, ‘deep-freeze’ graphs, ‘convoluted filtering’ networks, ‘mirror-image’ graphs, and adversarial ensemble methods are utilized to support inversion modeling for optimization of the complex compositions and complex processes in design of high-performing alloys, with their properties tailored to the energy application specifications.

Romanov, Vyacheslav↗

SU-E-I-82: Improving CT Image Quality for Radiation Therapy Using Iterative Reconstruction Algorithms and Slightly Increasing Imaging Doses

Purpose: Iterative reconstruction (IR) algorithms are developed to improve CT image quality (IQ) by reducing noise without diminishing spatial resolution or contrast. For CT in radiation therapy (RT), slightly increasing imaging dose to improve IQ may be justified if it can substantially enhance structure delineation. The purpose of this study is to investigate and to quantify the IQ enhancement as a result of increasing imaging doses and using IR algorithms. Methods: CT images were acquired for phantoms, built to evaluate IQ metrics including spatial resolution, contrast and noise, with a variety of imaging protocols using a CT scanner (Definition AS Open, Siemens) installed inside a Linac room. Representative patients were scanned once the protocols were optimized. Both phantom and patient scans were reconstructed using the Sinogram Affirmed Iterative Reconstruction (SAFIRE) and the Filtered Back Projection (FBP) methods. IQ metrics of the obtained CTs were compared. Results: IR techniques are demonstrated to preserve spatial resolution as measured by the point spread function and reduce noise in comparison to traditional FBP. Driven by the reduction in noise, the contrast to noise ratio is doubled by adopting the highest SAFIRE strength. As expected, increasing imaging dose reduces noise for both SAFIRE and FBP reconstructions. The contrast to noise increases from 3 to 5 by increasing the dose by a factor of 4. Similar IQ improvement was observed on the CTs for selected patients with pancreas and prostrate cancers. Conclusion: The IR techniques produce a measurable enhancement to CT IQ by reducing the noise. Increasing imaging dose further reduces noise independent of the IR techniques. The improved CT enables more accurate delineation of tumors and/or organs at risk during RT planning and delivery guidance.

60 APPLIED LIFE SCIENCES↗

Integrating Radio-Over-Fiber Communication System and BOTDR Sensor System

In this paper, we propose and experimentally demonstrate for the first time, the integration of a radio-over-fiber (RoF) communication system and a Brillouin optical time-domain reflectometry (BOTDR) distributed sensor system using a single optical fiber link. In this proof-of-concept integrated system, the communication system is composed of three modulation formats of quadrature phase-shift keying (QPSK), 16-quadrature amplitude modulation (16-QAM) and 64-QAM, which are modulated onto an orthogonal frequency division multiplexing (OFDM) signal. Whereas, the BOTDR sensor system is used for strain and/or temperature monitoring over the fiber distance with a spatial resolution of 5 m using a 25 km single-mode silica fiber. The error vector magnitude (EVM) is analyzed in three modulation formats in the presence of various BOTDR input pump powers. Using QPSK modulation, optimized 18 dBm sensing and 10 dBm data power, the measured EVM values with and without bandpass filter are 3.5% and 14.5%, respectively. The proposed system demonstrates a low temperature measurement error (±0.49 °C at the end of 25 km) and acceptable EVM values, which were within the 3GPP requirements. The proposed integrated system can be effectively applied for practical applications, which significantly reduces the fiber infrastructure cost by effective usage of a single optical fiber link.

42 ENGINEERING↗