Search NASA⌕ Search

SEARCH · Search NASA

Results for “full scale testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Tools for Predicting Optical Damage on Inertial Confinement Fusion-Class Laser Systems

Operating a fusion-class laser to its full potential requires a balance of operating constraints. On the one hand, the total laser energy delivered must be high enough to give an acceptable probability for ignition success. On the other hand, the laser-induced optical damage levels must be low enough to be acceptably handled with the available infrastructure and budget for optics recycle. Our research goal was to develop the models, database structures, and algorithmic tools (which we collectively refer to as ''Loop Tools'') needed to successfully maintain this balance. Predictive models are needed to plan for and manage the impact of shot campaigns from proposal, to shot, and beyond, covering a time span of years. The cost of a proposed shot campaign must be determined from these models, and governance boards must decide, based on predictions, whether to incorporate a given campaign into the facility shot plan based upon available resources. Predictive models are often built on damage ''rules'' derived from small beam damage tests on small optics. These off-line studies vary the energy, pulse-shape and wavelength in order to understand how these variables influence the initiation of damage sites and how initiated damage sites can grow upon further exposure to UV light. It is essential to test these damage ''rules'' on full-scale optics exposed to the complex conditions of an integrated ICF-class laser system. Furthermore, monitoring damage of optics on an ICF-class laser system can help refine damage rules and aid in the development of new rules. Finally, we need to develop the algorithms and data base management tools for implementing these rules in the Loop Tools. The following highlights progress in the development of the loop tools and their implementation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ceramic High Efficiency Particulate Air (HEPA) Filter (Final Report)

The technical objective of this project was to develop a ceramic HEPA filter technology, by initially producing and testing coupon ceramics, small scale prototypes, and full scale prototype HEPA filters, and to address relevant manufacturing and commercialization technical issues. The deliverable of the project would be a ceramic HEPA filter technology meeting the specifications of existing, glass fiber, nuclear grade HEPA systems. The existing HEPA filters are made from glass fiber, which is fragile and easily damaged due to impact by chemicals, high pressures and temperatures (see photographs in Fig. 1). A ceramic HEPA filter technology would overcome these problems and would allow the filter to be cleaned and reused, thereby reducing secondary waste. Additionally, ceramic HEPA filters will eliminate the associated costs and risks of contamination posed by "hot breaks" - the breaching of containment - required to periodically replace HEPA filters of current design. The ceramic HEPA filter technology would be designed to minimize retrofit problems and costs while meeting several key HEPA filter requirements.

36 MATERIALS SCIENCE↗

Additive Manufacturing of Porous Metal

Currently, helium is obtained through separation from natural gas. The current industrial process incurs significant costs and requires large energy resources to successfully achieve separation. Through utilizing Additive Manufacturing (AM) technologies it is possible to reduce both of these burdens when refining helium gas. The ability to engineer porosity levels within Inconel 718 discs for controlled separation of helium from natural gas was investigated. Arrays of samples fabricated using the electron beam melting process were analyzed for their relative porosity density. Based upon the measurements, full scale discs were fabricated, and subsequently tested to determine their effectiveness in separating helium from liquefied natural gas.

03 NATURAL GAS↗

Integrating Waste Heat from CO 2 Removal and Coal-Fired Flue Gas to Increase Plant Efficiency

In project DE-FE0007525, Southern Company Services demonstrated heat integration methods for the capture and sequestration of carbon dioxide produced from pulverized coal combustion. A waste heat recovery technology (termed High Efficiency System) from Mitsubishi Heavy Industries America was integrated into an existing 25-MW amine-based CO 2 capture process (Kansai Mitsubishi Carbon Dioxide Recovery Process®1) at Southern Company’s Plant Barry to evaluate improvements in the energy performance of the pulverized coal plant and CO 2 capture process. The heat integration system consists of two primary pieces of equipment: (1) the CO 2 Cooler which uses product CO 2 gas from the capture process to heat boiler condensate, and (2) the Flue Gas Cooler which uses air heater outlet flue gas to further heat boiler condensate. Both pieces of equipment were included in the pilot system. The pilot CO 2 Cooler used waste heat from the 25-MW CO 2 capture plant (but not always from product CO 2 gas, as intended). The pilot Flue Gas Cooler used heat from a slipstream of flue gas taken from downstream of Plant Barry’s air heater. The pilot also included a 0.25-MW electrostatic precipitator. The 25-MW High Efficiency System operated for approximately six weeks over a four month time period in conjunction with the 25-MW CO 2 capture facility at Plant Barry. Results from the program were used to evaluate the technical and economic feasibility of full-scale implementation of this technology. The test program quantified energy efficiency improvements to a host power plant that could be realized due to the High Efficiency System. Through the execution of this project, the team verified the integrated operation of the High Efficiency System and Kansai Mitsubishi Carbon Dioxide Recovery Process®. The ancillary benefits of the High Efficiency System were also quantified, including reduced water consumption, a decrease in toxic air emissions, and better overall air quality control systems performance.

20 FOSSIL-FUELED POWER PLANTS↗

An Integrated Flame Spray Process for Low Cost Production of Battery Materials for Lithium Ion Batteries and Beyond

The overall objective of this project was to develop an advanced manufacturing technology for Li-ion battery materials production at low cost and in a green chemical process using glycerol as solvent to replace water. It was aimed at developing a prototype pilot production line to reduce production cost by at least 25% to the baseline. During the course of this project, research was conducted to understand spray drying and combustion of eutectic solvent precursors of glycerol and metal salts (acetates) in the formation of mixed metal oxide powders. Reactor design and optimization were done to facilitate spray drying and combustion in powder formation and processing. Various cathode materials powders were produced, including lithium nickel-cobalt-manganese oxide (NCM) and lithium nickel-cobalt-aluminum oxide (NCA). These cathode materials powders were tested in half coin cells for their performances, with materials performances of 160 mAh/g for NCM111 and 200 mAh/g for NCA. NCA powders were also produced using a slurry spray-drying process and tested in full pouch cells. A pilot scale flame assisted spray drying reactor was constructed and demonstrated for its production rate exceeding the target of production rate of four metric tons per year. The work performed in this project has been documented in 9 peer reviewed journal publications, 8 conference presentations, and two IP disclosures/patent applications.

25 ENERGY STORAGE↗

Development of Low-Cost, High-Performance, Easy-To-Apply, Non-Flammable, Inorganic Phase Change Material (PCM) Technology (Project Final Report)

This report describes a 45-months long research program focused on the development of novel, easy-to-apply, non-flammable, and high-performance inorganic phase change materials (PCMs) for building and industrial applications. The University of Massachusetts Lowell (UML) formed a world-class team consisting of researchers form InsolCorp (only N. American manufacturer of inorganic PCM systems for building applications), and a group of industrial advisors, to develop a universal/multipurpose, simple-to-manufacture and cost-effective PCM technology. The project team expects that the results of this work will spur in the future the adoption of thermal storage materials – a key building energy saving technology as identified by DOE BTO – for a variety of building envelope applications. The main goal of this project was to demonstrate a suite of low-cost, multipurpose, and durable inorganic PCM formulations with phase transition temperatures encompassing typical building applications (between +5 o C and +55 o C). The first objective was to design, fabricate, and experimentally validate a performance of inexpensive, durable, highly efficient, non-flammable, and easy to manufacture PCMs. To allow a variety of building applications, the project team focused on formulations that exhibit repeatable phase transitions between +5 o C and +55 o C. To follow the DOE BTO cost efficiency target without compromising thermal performance, our work was based on inorganic compounds (mostly salt hydrates) and their blends, which represent a fraction of the cost of most of organic PCMs with about twice as high density as well as significantly higher thermal conductivity and phase change enthalpy. The second objective was to develop easy-to-manufacture and -install packaging/encapsulation designs that are 1) a superior barrier to current state-of-the-art macro-packaging, which significantly reduces the risk of loss of hydration water and PCM leak, and 2) optimal in enhancing the heat exchange rates with the surroundings and within the PCM core to ensure complete charging/discharging of the entire PCM within the product. Finally, the project’s intend was to scale-up the fabrication process to demonstrate installation on system-scale applications, and to validate the performance under field conditions. This work aimed at developing low-cost, high-energy storage, and reliable latent heat storage technology for building applications. This development was realized by formulating and integrating the following two technology components: 1) inorganic salt hydrate based PCMs that have high latent enthalpies and are low-cost and durable, and 2) PCM encapsulation (packaging) technology that maximizes PCM concentration and enhances heat transport characteristics in the product and with the external environment/materials. High thermal storage capacity, low cost and fire resistance are key to the building market entry for PCM technology. Therefore, the project’s focus was on salt-hydrate-based formulations which satisfy all these criteria. Packaging and/or encapsulation of PCM is a key processing step. The project team recognized that a low-cost and simple-to-manufacture salt hydrate-based PCM technology holds the best chance to be successful in the building construction market, a market which is traditionally extremely sensitive to cost and where commodity thermal insulations are the benchmark for envelope-related energy saving measures. That is why, in this project, the main intention was to minimize the production cost and maximize the product energy storage density without sacrificing the PCM performance. It was achieved through: 1. Minimizing the non-PCM components (plastics, additives, packaging/encapsulation materials, etc.) because they are significantly more expensive than salt hydrates, 2. Using highly thermally conductive and lightweight PCM carrier (packaging material) to facilitate more complete phase cycling, and 3. Optimizing the thickness and minimizing air spaces in product design (such as in pouched PCM). For this purpose, our approach was to enable an easy system design, including selection of the PCM operating temperatures, optimizing the necessary heat storage capacity (by stacking together several layers of PCM products), and if needed, a synchronized usage of PCM products of different temperatures. A specially designed, robust, highly thermally conducting and highly impermeable packaging (to retain salt hydrate water during phase transition cycles) was designed and tested to increase the overall system thermal performance and durability. All PCM products developed during this project were tested in both lab scale and in full scale field conditions. It is expected that, after further developments and commercialization, the developed PCM technologies may be also applied in space conditioning, energy storage technologies, and heat transfer applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Evaluation of the Micro-Environmental Control System in Maintaining Thermal Comfort

The micro-environment in this study refers to the air space and environment around a person that directly impacts his/her thermal sensation. Most existing HVAC systems condition the air of the entire room including the unoccupied space, which leaves a big potential to save energy. This study aims at evaluating the performance of three existing air terminal devices (ATDs) and two heating delivering devices (HDDs) to manage the thermal balance so as not to sacrifice thermal comfort when the ambient unoccupied space temperature is expanded from 21.1-23.9 °C to 18.9-26.1 °C to reduce HVAC load. A 20-segment thermal manikin was put in a full-scale stainless-steel chamber to test with selected ATDs and HDDs. Results show that all the three ATDs with only 50 W cooling power and the heating mat with a reflective box using 60 W heating power were able to recover the thermal comfort in a room of expanded temperature set-point. The cooling performance of the jet was increased more by increasing the supply airflow rate than reducing the supply air temperature, and 8.0 L/s flow rate could remove more than 15.6 W from the manikin. A heating mat that heated the feet by conduction was more efficient than the heating bulb, and with 60 W heating power, it could reduce the heat loss from the manikin by more than 12.2 W.

Kong, Meng↗

Concepts and Tests for the Remote-Controlled Dismantling of the Biological Shield and Form work of the KNK Reactor - 13425

The compact sodium-cooled nuclear reactor facility Karlsruhe (KNK), a prototype Fast Breeder, is currently in an advanced stage of dismantling. Complete dismantling is based on 10 partial licensing steps. In the frame of the 9. decommissioning permit, which is currently ongoing, the dismantling of the biological shield is foreseen. The biological shield consists of heavy reinforced concrete with built-in steel fitments, such as form-work of the reactor tank, pipe sleeves, ventilation channels, and measuring devices. Due to the activation of the inner part of the biological shield, dismantling has to be done remote-controlled. During a comprehensive basic design phase a practical dismantling strategy was developed. Necessary equipment and tools were defined. Preliminary tests revealed that hot wire plasma cutting is the most favorable cutting technology due to the geometrical boundary conditions, the varying distance between cutter and material, and the heavy concrete behind the steel form-work. The cutting devices will be operated remotely via a carrier system with an industrial manipulator. The carrier system has expandable claws to adjust to the varying diameter of the reactor shaft during dismantling progress. For design approval of this prototype development, interaction between manipulator and hot wire plasma cutting was tested in a real configuration. For the demolition of the concrete structure, an excavator with appropriate tools, such as a hydraulic hammer, was selected. Other mechanical cutting devices, such as a grinder or rope saw, were eliminated because of concrete containing steel spheres added to increase the shielding factor of the heavy concrete. Dismantling of the biological shield will be done in a ring-wise manner due to static reasons. During the demolition process, the excavator is positioned on its tripod in three concrete recesses made prior to the dismantling of the separate concrete rings. The excavator and the manipulator carrier system will be operated alternately. Main boundary condition for all the newly designed equipment is the decommissioning housing of limited space within the reactor building containment. To allow for a continuous removal of the concrete rubble, an additional opening on the lowest level of the reactor shaft will be made. All equipment and the interaction of the tools have to be tested before use in the controlled area. Therefore a full-scale model of the biological shield will be provided in a mock-up. The tests will be performed in early 2014. The dismantling of the biological shield is scheduled for 2015. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Advanced dismantling techniques applied in an industrial project for the dismantling of highly activated equipment - 15446

Commissioned in 1958 on the CEA nuclear site of Marcoule (France) and shut down in 1997, the former UP1 plant was dedicated to reprocess the spent fuel from G1, G2 and G3 GCR reactors. Since 1998, a wide program for cleaning-up and dismantling the plant has been developed in order to dismantle the process equipment, eliminate any radiological risk in all buildings concerned and remove all the resulting waste. Major technical challenges are related to the wide range of complex components and equipment in the facilities such as chemical dissolvers, extractor batteries, evaporators, tanks; and to a high risk of exposure, due to the presence of fission products. To address these challenges, CEA led R and D programs to develop advanced tools for complex dismantling projects: immersive virtual reality, laser cutting techniques, special remote-controlled arms combining dexterity and high resistance to irradiation The purpose of this paper is to provide an overview of a practical implementation and to show first results of these advanced techniques on a real case: the dismantling of dissolver's equipment from the dissolution workshop of UP1 plant. ONET Technologies has been chosen by CEA to design, build and operate the overall dismantling and waste treatment system for this project. ONET Technologies designed two main subsystems to meet all the requirements for this project: first, the 'Remotely-Operated Handling and Cutting Unit' and second the 'Waste Extraction and Conditioning Unit' and the combining innovative technologies. During the design phase, the 'Immersive Virtual Reality' has been used to qualify the kinematics in the final environment and the preliminary dismantling scenario. Following a first R and D program of CEA regarding the laser cutting technique applied to nuclear decommissioning, ONET Technologies and CEA realized elementary inactive tests based on a 6 kW Nd-Yag laser source to qualify the cutting performance according to material and thickness. Main objective was to meet the safety criteria and to check the physical characteristics of waste resulting from the laser cutting operation. The Remotely-Operated Handling and Cutting Unit was equipped with a MAESTRO manipulator, resulting from ten years of research and development cooperation between CEA and Cybernetix. This manipulator, a 6 axis hydraulic manipulator-arm specifically designed to work in harsh environment, entered in its industrial phase. ONET Technologies was responsible for the overall system integration, confinement and performance. A comprehensive qualification program in real conditions has been driven during 2014. The dismantling scenario was tested with a mockup at a full scale of dissolver equipment and confirmed at this stage the expected level of performance and safety. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

30 cm Drop Tests

The data from the multi-modal transportation test conducted in 2017 demonstrated that the inputs from the shock events during all transport modes (truck, rail, and ship) were amplified from the cask to the spent commercial nuclear fuel surrogate assemblies. These data do not support common assumption that the cask content experiences the same accelerations as the cask itself. This was one of the motivations for conducting 30 cm drop tests. The goal of the 30 cm drop test is to measure accelerations and strains on the surrogate spent nuclear fuel assembly and to determine whether the fuel rods can maintain their integrity inside a transportation cask when dropped from a height of 30 cm. The 30 cm drop is the remaining NRC normal conditions of transportation regulatory requirement (10 CFR 71.71) for which there are no data on the actual surrogate fuel. Because the full-scale cask and impact limiters were not available (and their cost was prohibitive), it was proposed to achieve this goal by conducting three separate tests. This report describes the first two tests — the 30 cm drop test of the 1/3 scale cask (conducted in December 2018) and the 30 cm drop of the full-scale dummy assembly (conducted in June 2019). The dummy assembly represents the mass of a real spent nuclear fuel assembly. The third test (to be conducted in the spring of 2020) will be the 30 cm drop of the full-scale surrogate assembly. The surrogate assembly represents a real full-scale assembly in physical, material, and mechanical characteristics, as well as in mass.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sandia's Twistact Technology: Decarbonization of the Energy Sector in the 2030 Time Frame.\

As of 2018, renewable energy sources such as wind and solar have the lowest unsubsidized levelized cost of energy, and grid-scale storage solutions are being aggressively developed and deployed. However, for a carbon-free energy generation paradigm to be realistic, any impediments to scalability must be addressed. In the wind industry, dependence on rare-earth (RE) magnets in direct-drive generators represents a significant roadblock to widespread technology proliferation. Sandia’s Twistact technology is a fundamentally new rotary electrical contact with only rolling metal-to- metal contact that eliminates the need for RE magnets by enabling a wire-wound generator architecture with no efficiency or cost penalties. This report summarizes work funded by an LDRD in FY16—18, in which we advanced the technology readiness level (TRL) of Twistact technology to TRL 5 and proved the viability of a Twistact-based generator for utility-scale, direct-drive wind turbines. We conducted coupon-level tests of rolling metallic contacts and developed a tribological model that predicts operation in either a low-wear or high-wear regime. We also built device-level testing apparatuses and observed operation of full-scale Twistact devices, which corroborated the predictions of the tribological model and demonstrated over 50 million rotation cycles (30-year lifetime in a direct-drive generator). Indeed, the present work demonstrated that Twistact technology has potential to be an enabling technology that eliminates RE magnet dependence in the wind industry. The next logical step is commercialization of Twistact technology (currently at TRL 5) in partnership with a generator original equipment manufacturer that already has an established presence in the wind power industry.

42 ENGINEERING↗

Glass Frit Clumping and Dusting

DWPF mixes a slurry of glass frit (Frit 418) and dilute (1.5 wt%) formic acid solution with high level waste in the Slurry Mix Evaporator (SME). There would be advantages to introducing the frit in a non-slurry form to minimize water addition to the SME, however, adding completely dry frit has the potential to generate dust which could clog filters or condensers. Prior testing with another type of frit, Frit 320, and using a minimal amount of water reduced dust generation, however, the formation of hard clumps was observed. To examine options and behavior, a TTQAP [McCabe and Stone, 2013] was written to initiate tests that would address these concerns. Tests were conducted with four types of glass frit; Frit 320, DWPF Frit 418, Bekeson Frit 418 and Multi-Aspirator Frit 418. The last two frits are chemically identical to DWPF Frit 418 but smaller particles were removed by the respective vendors. Test results on Frit Clumping and Dusting are provided in this report. This report addresses the following seven questions. Short answers are provided below with more detailed answers to follow. 1. Will the addition of a small amount of water, 1.5 wt%, to dry DWPF Frit 418 greatly reduce the dust generation during handling at DWPF? a. Yes, a small scale test showed that adding a little water to the frit greatly reduced dust generation during handling. 2. Will the addition of small amounts of water to the frit cause clumping that will impair frit handling at DWPF? a. No, not with Frit 418. Although clumps were observed to form when 1.5 wt% water was mixed with DWPF Frit 418, then compressed and air-dried overnight, the clumps were easily crushed and did not form the hardened material noted when Frit 320 was tested. 3. What is the measured size distribution of dust generated when dry frit is handled? (This affects the feasibility and choice of processing equipment for removing the dust generating fraction of the frit before it is added to the SME.) a. The size distribution for the dust removed from fresh DWPF Frit 418 while it was being shaken in a small scale LabRAM test was measured. The median size on a volume basis was 7.6 μm and 90% of the frit particles were between 1.6 and 28 μm. The mass of dust collected using this test protocol was much less than 1% of the original frit. 4. Can the dust be removed in a small number of processing steps and without the larger frit particles continuing to spall additional dust sized particles? a. Test results using a LabRAM were inconclusive. The LaRAM performs less efficient particle size separation than the equipment used by Bekeson and Multi-Aspirator. 5. What particle size of frit is expected to create a dust problem? a. The original criterion for creating a dusting problem was those particle sizes that were readily suspended when being shaken. For that criterion calculations and Microtrac size analyses indicated that particles smaller than 37 μm are likely dust generators. Subsequently a more sophisticated criterion for dust problem was considered, particle sizes that would become suspended in the air flow patterns inside the SME and possibly plug the condenser. That size may be larger than 37 μm but has not yet been determined. 6. If particles smaller than 37 μm are removed will bulk dust generation be eliminated? a. Video-taped tests were performed using three gallons each of three types of frit 418, DWPF frit, Bekeson frit and Multi-Aspirator frit. Frit was poured through air from a height of approximately eight feet into a container half filled with water. Pouring Bekeson frit or Multi-Aspirator frit generated markedly less visible dust, but there was still a significant amount, which still has the potential of causing a dust problem. 7. Can completely dry frit be poured into the SME without having dust plug the condenser at the top of the vessel? a. Because of the complexity of air currents inside the SME and the difficulty of defensible size scaling a more prototypical test will be required to answer this question. We recommend construction of a full scale mockup of the top half of the SME with a shallow basin of water at the bottom and a simulated condenser at the top. It could be made from simple materials such as PVC pipe, cardboard and clear plastic and tested with dry frit. Depending on results, this may need to be coupled with the proposed pneumatic transfer system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DEVELOPMENT OF A CROSSFLOW FILTER TO REMOVE SOLIDS FROM RADIOACTIVE LIQUID WASTE: COMPARISON OF TEST DATA WITH OPERATING EXPERIENCE - 9119

In 2008, the Savannah River Site (SRS) began treatment of liquid radioactive waste from its Tank Farms. To treat waste streams containing {sup 137}Cs, {sup 90}Sr, and actinides, SRS developed the Actinide Removal Process (ARP) and the Modular Caustic Side Solvent Extraction Unit (MCU). The Actinide Removal Process contacts the waste with monosodium titanate (MST) to sorb strontium and select actinides. After MST contact, the process filters the resulting slurry to remove the MST (with sorbed strontium and actinides) and any entrained sludge. The filtrate is transported to the MCU to remove cesium. The solid particle removed by the filter are concentrated to {approx} 5 wt %, washed to reduce the concentration of dissolved sodium, and transported to the Defense Waste Processing Facility (DWPF) for vitrification. The authors conducted tests with 0.5 {micro} and 0.1 {micro} Mott sintered stainless steel crossflow filter at bench-scale (0.19 ft{sup 2} surface area) and pilot-scale (11.2 ft{sup 2}). The collected data supported design of the filter for the process and identified preferred operating conditions for the full-scale process (230 ft{sup 2}). The testing investigated the influence of operating parameters, such as filter pore size, axial velocity, transmembrane pressure, and solids loading, on filter flux, and validated the simulant used for pilot-scale testing. The conclusions from this work follow: (1) The 0.1 {micro} Mott sintered stainless steel filter produced higher flux than the 0.5 {micro} filter. (2) The filtrate samples collected showed no visible solids. (3) The filter flux with actual waste is comparable to the filter flux with simulated waste, with the simulated waste being conservative. This result shows the simulated sludge is representative of the actual sludge. (4) When the data is adjusted for differences in transmembrane pressure, the filter flux in the Actinide Removal Process is comparable to the filter flux in the bench-scale and pilot-scale testing. (5) Filter flux increased with transmembrane pressure, increased with axial velocity, and decreased with concentration in agreement with classical crossflow filtration theories.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PILOT-SCALE HYDRAULIC TESTING OF RESORCINOL FORMALDEHYDE ION EXCHANGE RESIN

Savannah River National Laboratory (SRNL) performed pilot-scale hydraulic/chemical testing of spherical resorcinol formaldehyde (RF) ion exchange (IX) resin for the River Protection Project-Hanford Tank Waste Treatment & Immobilization Plant (WTP) Project. The RF resin hydraulic cycle testing was conducted in two pilot-scale IX columns, 1/4 and 1/2 scale. A total of twenty-three hydraulic/chemical cycles were successfully completed on the spherical RF resin. Sixteen of these cycles were completed in the 24-inch IX Column (1/2 scale column). Hydraulic testing showed that the permeability of the RF resin remained essentially constant, with no observed trend in the reduction of the permeability as the number of cycles increased. The permeability during the pilot-scale testing was 3 times better than the design requirements of the WTP full-scale IX system. The RF resin bed showed no tendency to form fissures or pack more densely as the number of cycles increased. Particle size measurements of the RF resin showed no indication of particle size change (for a given chemical) with cycles and essentially no fines formation. The permeability of the resin bed was uniform with respect to changes in bed depth. Upflow Regeneration and Simulant Introduction in the IX columns revealed another RF resin benefit; negligible radial pressures to the column walls from the swelling of resin beads. The hydraulic and chemical performance of the spherical RF resin during cycle testing was found to be superior to all other tested IX resins. The pilot-scale testing indicates that the RF resin is durable and should hold up to many hydraulic cycles in actual radioactive Cesium (Cs) separation.

99 GENERAL AND MISCELLANEOUS↗

Development and Testing of a High Level Waste Slurry Sampling Technique to Support Hanford Waste Processing - 17164

The Hanford Tank Operations Contractor must demonstrate the capability to adequately sample staged high-level waste feed. The sampler employed must have accuracy and precision performance that allow the Tank Operations Contractor (TOC) to meet the Waste Treatment and Immobilization Plant (WTP) Waste Acceptance Criteria Data Quality Objectives (DQO). A full-scale sampling loop was used at a test facility to develop and demonstrate sampler capability. This paper will discuss the modifications to a sampler configuration previously tested - modifications focused on the improvement of the accuracy of test results. This work targets one of the remaining technical issues with the high-level waste treatment mission at Hanford. The sampling method employed must support both Tank Operations and Waste Treatment and Immobilization Plant requirements. To facilitate information transfer between the two facilities the mixing and sampling demonstrations are led by the TOC's Chief Technology Office in conjunction with the One System Integrated Project Team. Results of the testing showed that performance of the Isolok{sup R} sampler, chosen for implementation, can be greatly improved by modifying the systems configuration to provide accurate, repeatable results for Hanford's simulated high level waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Final Technical Report

In September 2010, RTI and the DOE/NETL signed a cooperative agreement (DE-FE000489) to design, build, and operate a pre-commercial syngas cleaning system that would capture up to 90% of the CO 2 in the syngas slipstream, and demonstrate the ability to reduce syngas contaminants to meet DOE’s specifications for chemical production application. This pre-commercial syngas cleaning system is operated at Tampa Electric Company’s (TEC) 250-MWe integrated gasification combined cycle (IGCC) plant at Polk Power Station (PPS), located near Tampa, Florida. The syngas cleaning system consists of the following units: Warm Gas Desulfurization Process (WDP) - this unit processes a syngas flow equivalent of 50 MWe of power (50 MWe equivalent corresponds to about 2.0 MM scfh of syngas on dry basis) to produce a desulfurized syngas with a total sulfur (H 2 S+COS) concentration ~ 10 ppmv. Water Gas Shift (WGS) Reactor - this unit converts sufficient CO into CO 2 to enable 90% capture of the CO 2 in the syngas slipstream. This reactor uses conventional commercial shift catalyst technologies. Low Temperature Gas Cooling (LTGC) - this unit cools the syngas for the low temperature activated MDEA process and separates any condensed water. Activated MDEA Process (aMDEA) - this unit employs a non-selective separation for the CO 2 and H 2 S present in the raw syngas stream. Because of the selective sulfur removal by the upstream WDP unit, the CO 2 capture target of 90% CO 2 can be achieved with the added benefit that total sulfur concentration in the CO 2 product is < 100 ppmv. An additional advantage of the activated MDEA process is that the non-selective sulfur removal from the treated syngas reduces sulfur in the treated gas to very low sub-ppmv concentrations, which are required for chemical production applications. Testing to date of this pre-commercial syngas cleaning system has shown that the technology has great potential to provide clean syngas from coal and petcoke-based gasification at increased efficiency and at significantly lower capital and operating costs than conventional syngas cleanup technologies. However, before the technology can be deemed ready for scale-up to a full commercial-scale demonstration, additional R&D testing is needed at the site to address the following critical technical risks: WDP sorbent stability and performance; Impact of WDP on downstream cleanup and conversion steps; Metallurgy and refractory; Syngas cleanup performance and controllability; Carbon capture performance and additional syngas cleanup The proposed plan to acquire this additional R&D data involves: Operation of the units to achieve an additional 3,000 hours of operation of the system within the performance period, with a target of achieving 1,000 hours of those hours via continuous operation of the entire integrated pre-commercial demonstration system; Rapid turnaround of repairs and/or modifications required as necessary to return any specific unit to operating status with documentation and lessons learned to support technology maturation, and; Proactive performance of maintenance activities during any unplanned outages and if possible while operating.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗