Search NASA⌕ Search

SEARCH · Search NASA

Results for “high angular resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Advanced Technology Large-Aperture Space Telescope: Science Drivers and Technology Developments

The Advanced Technology Large-Aperture Space Telescope (ATLAST) is a concept for an 8- to 16-m ultraviolet optical near Infrared space observatory for launch in the 2025 to 2030 era. ATLAST will allow astronomers to answer fundamental questions at the forefront of modern astrophysics, including: Is there life elsewhere in the Galaxy? We present a range of science drivers and the resulting performance requirements for ATLAST (8- to 16-marcsec angular resolution, diffraction limited imaging at 0.5 micron wavelength, minimum collecting area of 45 sq m, high sensitivity to light wavelengths from 0.1 to 2.4 micron, high stability in wavefront sensing and control). We also discuss the priorities for technology development needed to enable the construction of ATLAST for a cost that is comparable to that of current generation observatory-class space missions.

Postman, Marc↗

Detecting the Attenuation of Blazar Gamma-ray Emission by Extragalactic Background Light with GLAST

Gamma rays with energy above 10 GeV interact with optical-UV photons resulting in pair production. Therefore, a large sample of high redshift sources of these gamma rays can be used to probe the extragalactic background starlight (EBL) by examining the redshift dependence of the attenuation of the flux above 10 GeV. GLAST, the next generation high-energy gamma-ray telescope, will for the first time have the unique capability to detect thousands of gamma-ray blazars up to redshifts of at least z = 4, with enough angular resolution to allow identification of a large fraction of their optical counterparts. By combining recent determinations of the gamma-ray blazar luminosity function, recent calculations of the high energy gamma-ray opacity due to EBL absorption, and the expected GLAST instrument performance to produce simulated samples of blazars that GLAST would detect, including their redshifts and fluxes, we demonstrate that these blazars have the potential to be a highly effective probe of the EBL.

Chen, Andrew↗

New high-resolution rocket-ultraviolet filtergrams of the solar disc

A rocket-borne solar ultraviolet telescope named Transition Region Camera was launched successfully for the third on July 13, 1982. High quality calibrated photographic images of the sun were obtained at Lyman alpha and in the continuum at 160 nm and 220 nm. The angular resolution achieved is better than one arcsec. A flare, active regions, sunspots, the 8 Mm mesostructure, the chromospheric network, bright UV grains and coronal loops were observed during the flight. The results are presented and the evolution with height in the solar atmosphere of the various structures observed is followed from one wavelength to the other, showing distinct differences. The value of the field's intensity of magnetic flux tubes is deduced from the observations.

Foing, B.↗

VLA Imaging of Protoplanetary Environments

We continue to use the Very Large Array (VLA) of the National Radio Astronomy Observatories (NRAO) to make high resolution images of thermal emission in the protoplanetary environment of nearby young stars. The VLA provides two unique capabilities. First, the angular resolution for imaging thermal emission is unmatched by any other facility. For the A array, the synthesized beam at a wavelength of 7 mm corresponds to a linear scale similar to the orbital radius of Jupiter at the distance of nearby dark clouds Eke Taurus. Second, the long millimeter wavelengths accessible to the VLA are particularly advantageous at this high resolution since the emission is (almost) entirely optically thin and probes the full disk column, including the innermost regions that remain opaque to shorter wavelengths.

Wilner, David J.↗

The Extreme Ultraviolet Normal Incidence Spectrograph (EUNIS)

EUNIS (Extreme Ultraviolet Normal Incidence Spectrograph) is a high-efficiency extreme ultraviolet spectrometer that is expected to fly for the first time in 2004 as a sounding rocket payload. Using two independent optical systems, EUNIS will probe the structure and dynamics of the inner solar corona high spectral resolution in two wavelength regions: 17-21 nm with 3.5 pm resolution and 30-37 nm with 7 pm resolution. The long wavelength channel includes He II 30.4 nm and strong lines from Fe XI-XVI; the short wavelength channel includes strong lines of Fe IX-XIII. Angular resolution of 2 arcsec is maintained along a slit covering a full solar radius. EUNIS will have 100 times the throughput of the highly successful SERTS payloads that have preceded it. There are only two reflections in each optical channel, from the superpolished, off-axis paraboloidal primary and the toroidal grating. Each optical element is coated with a high-efficiency multilayer coating optimized for its spectral bandpass. The detector in each channel is a microchannel plate image intensifier fiber- coupled to three 1K x 1K active pixel sensors. EUNIS will obtain spectra with a cadence as short as 1 sec, allowing unprecedented studies of the physical properties of evolving and transient structures. Diagnostics of wave heating and reconnection wil be studied at heights above 2 solar radii, in the wind acceleration region. The broad spectral coverage and high spectral resolution will provide superior temperature and density diagnostics and will enable underflight calibration of several orbital instruments, including SOHO/CDS and EIT, TRACE, Solar-B/EIS, and STEREO/EUVI. EUNIS is supported by NASA through the Low Cost Access to Space Program in Solar and Heliospheric Physics.

Oegerle, William↗

Large-aperture high-resolution X-ray collimator for the Solar Maximum Mission

A description is presented of a flight-qualified large-aperture 12 x 12-arcsec angular resolution multigrid X-ray collimator developed for the Solar Maximum Mission (SMM) flat crystal spectrometer. This collimator, designed for the 1.4-22.4-A wavelength range, utilizes an optical bench/metering structure to align and support prealigned grid subassemblies. The optical bench is a lightweight, rigid, and stable aluminum honeycomb structure. The grids are of a compound and bimetallic design, having 63.5-micron square holes on an 88.9-micron spacing in 8-micron thick gold, which is in turn supported by a 76-micron thick Invar grid having 600-micron square holes on a 739-micron spacing. The small apertures in the gold provide the 12-arcsec collimation with the Invar grids providing wide angle off-axis blocking out to an approximately 35 arcmin view angle. The collimator has seven individual channels, four of a 5.1- x 10-cm area and three of a 1.3- x 10-cm area. Laboratory measurements gave an average angular resolution of 12.5 arcsec FWHM with 0.259 transmission for the large-area channels and 12.0 arcsec and 0.200 transmission for the small-area channels. A thermal filter composed of two layers of approximately 1000-A thick aluminum prevents solar heating of the front collimator grids by absorbing longer wavelength radiation while passing most of the X radiation in the band of interest.

Nobles, R. A.↗

Survey of the galactic background radiation at 3.93 and 6.55 MHz

A survey of the galactic background radiation at 3.93 and 6.55 MHz is presented for the region between declinations of -60 and +60 deg. The observations were obtained with the 229-m traveling-wave V-antenna on the Radio Astronomy Explorer-1 satellite with an angular resolution of the order of one steradian. The results are consistent with the findings of high-resolution ground-based surveys at low frequencies and provide a first step in extending such observations over the whole sky.

Alexander, J. K.↗

The Circumstellar Environment of Low Mass Star Forming Regions

The final technical report of the NASA grant project is presented. The goals of the grant were to: (1) analyze the data from the Far-Infrared (FIR) Camera on board the Kuiper Airborne Observatory (KAO); (2) acquire additional data at other wavelengths for models and (4) to develop source models for the Young stellar objects (YSOs)under study. The complete Spectral Energy Distribution (SED) from 10 microns out to 1.3 mm for all sources being studied have been obtained. The FIR imaging data was processed to reveal the maximum angular resolution possible, which allows us to model the disk. To model the disk we have the high resolution millimeter interferometry data. In summary the results to date are: (1) the vast majority of embedded YSOs in Taurus are compact at 100 microns. The models mos consistent with our data and other observations are either dominated by disk emissions, or envelopes that have relatively steep density gradients; (2) the submillimeter/millimeter photometer suggests that models are very successful. Disk emission plays an important role and must be considered when predicting the overall emission. (3) in the two cases, where we seem to have extended emission, we have to investigate other possible source models than a Shu collapse.

Butner, Harold M.↗

Prospects for GLAST

The Gamma-ray Large Area Space Telescope (GLAST), scheduled for launch in late 007, is a satellite based observatory to study the high energy gamma-ray sky. There are two instruments on GLAST: the Large Area Telescope (LAT) which provides coverage from 20 MeV to over 300 GeV, and the GLAST Burst Monitor (GBM) which provides supportive observations of transients from 8 keV to 30 MeV. GLAST will provide well beyond those achieved by the highly successful EGRET instrument on the Compton Gamma-Ray Observatory, with dramatic improvements in sensitivity, angular resolution and energy range. The very large field of view will make it possible to observe approx. 20% of the sky at any instant, and the entire sky on timescale of a few hours. This talk includes a description of the instruments, the opportunities for guest investigators, and the mission status.

McEnery, Julie↗

Design of Optical/IR Blocking Filters for the Lynx X-Ray Microcalorimeter

The Lynx mission concept, under development ahead of the 2020 Astrophysics Decadal Review, includes the Lynx X-ray Microcalorimeter (LXM) as one of its primary instruments. The LXM uses a microcalorimeter array at the focus of a high-throughput soft x-ray telescope to enable high-resolution nondispersive spectroscopy in the soft x-ray waveband (0.2 to 15 keV) with exquisite angular resolution. Similar to other x-ray microcalorimeters, the LXM uses a set of blocking filters mounted within the dewar that pass the photons of interest (x-rays) while attenuating the out-of-band long-wavelength radiation. Such filters have been successfully used on previous orbital and suborbital instruments; however, the Lynx science objectives, which emphasize observations in the soft x-ray band (<1keV), pose more challenging requirements on the set of LXM blocking filters. We present an introduction to the design of the LXM optical/IR blocking filters and discuss recent advances in filter capability targeted at LXM. In addition, we briefly describe the external filters and the modulated x-ray sources to be used for onboard detector calibration.

Eckart, Megan E.↗

Detailed Characterization of CZT Detector Response for Improved Coded-Aperture Imaging Performance

Gamma-ray imaging is a powerful method for locating and quantifying sources of radiation. The coded-aperture technique demonstrates superior angular resolution in comparison to other methods (e.g., Compton reconstruction). In this method, a mask constructed of highly attenuating material encodes the scene as a shadow pattern on a position-sensitive detector; this pattern can then be used to recreate the origin(s) of incident radiation. This is typically done through convolution of the mask and shadow patterns. Iterative methods which attempt to reconstruct the observed shadow pattern using a weighted combination of simulated patterns may also be employed. In either case, errors in event position reconstruction due to detector imperfections alter the shadow pattern and will therefore degrade system performance and may introduce imaging artifacts. These effects can be mitigated with a detailed understanding of such errors – allowing for the generation of representative simulations that include the errors and/or correction of raw imager data to remove the errors. We present a calibration process for a commercially available cadmium zinc telluride (CZT) gamma imager which provides a comprehensive characterization of the spatial and energy dependence of event reconstruction. By illuminating a mask featuring a regular grid of pinholes with a calibration source, the localized response of the detector can be measured with fine granularity. These local responses are combined to generate a full detector response map which can be used to distort simulations in a manner that is representative of the observed detector data. Details of the calibration procedure and an assessment of the impact of its end products on the performance of iterative imaging methods will be presented.

Ziock, Klaus-Peter↗

The future of high energy gamma ray astronomy and its potential astrophysical implications

Future satellites should carry instruments having over an order of magnitude greater sensitivity than those flown thus far as well as improved energy and angular resolution. The information to be obtained from these experiments should greatly enhance knowledge of: the very energetic and nuclear processes associated with compact objects; the structure of our galaxy; the origin and dynamic pressure effects of the cosmic rays; the high energy particles and energetic processes in other galaxies; and the degree of matter-antimatter symmetry of the universe. The relevant aspects of extragalactic gamma ray phenomena are emphasized along with the instruments planned. The high energy gamma ray results of forthcoming programs such as GAMMA-1 and the Gamma Ray Observatory should justify even more sophisticated telescopes. These advanced instruments might be placed on the space station currently being considered by NASA.

Fichtel, C. E.↗

A comparison of high resolution radio and far-infrared maps of M 17

New 3.5-cm radio and 69-micron far-infrared maps of M17, both made with an angular resolution of about 1.5 arcmin, are presented. Each map has three distinct maxima. Two of the maxima on the far-IR map agree in position with the corresponding maxima on the radio map. However, the positions of the brightest peak in the radio and far-infrared maps, located in the SW part of M17, differ by 4.6 + or - 2.2 s in right ascension and +44 + or - 20 sec in declination, with the far-infrared peak lying between the radio peak and the dense molecular cloud southwest of the H II region. It is believed that the positional offset of the radio and far-infrared peak is physically significant. The origin of the far-infrared radiation appears to be thermal emission from dust at the interface of the ionized gas and molecular cloud. This interface region is probably heated by radiation from the H II region.

Wilson, T. L.↗

AXSIO and the NASA X-ray Mission Concept Study

The Advanced X-ray Spectroscopy and Imaging Observatory (AXSIO) focuses on the IXO science objectives ranked highly by the Decadal Survey: tracing orbits near 5MBH event horizons, measuring BH spin, characterizing outflows and the environment of AGN, observing 5MBH to z=6, mapping gas motion in clusters, finding the missing baryons, and observing cosmic feedback. AXSIO's streamlining of IXO includes reduction in the instrument complement to a calorimeter and a grating spectrometer, and relaxation of the angular resolution to 10". With 0.9 m2 effective area at 1.25 keV, AXSIO delivers a 30-fold performance increase over current missions for high-resolution spectroscopy and spectroscopic timing. NASA has also undertaken a study of notional missions to determine lower cost approaches to accomplishing IXO objectives over the next decade. Three concepts were studied; which as a group encompass the full range of IXO science. The capabilities and architecture of these missions are summarized.

Petre, Robert↗

Stars at High Spatial Resolution

We summarize some of the compelling new scientific opportunities for understanding stars and stellar systems that can be enabled by sub-milliarcsec (sub-mas) angular resolution, UV/Optical spectral imaging observations, which can reveal the details of the many dynamic processes (e.g., evolving magnetic fields, accretion, convection, shocks, pulsations, winds, and jets) that affect stellar formation, structure, and evolution. These observations can only be provided by long baseline interferometers or sparse aperture telescopes in space, since the aperture diameters required are in excess of 500 m – a regime in which monolithic or segmented designs are not and will not be feasible - and since they require observations at wavelengths (UV) not accessible from the ground. Such observational capabilities would enable tremendous gains in our understanding of the individual stars and stellar systems that are the building blocks of our Universe and which serve as the hosts for life throughout the Cosmos.

Kenneth G Carpenter↗

VTXO: The Virtual Telescope for X-ray Observations

The Virtual Telescope for X-ray Observations (VTXO) will use lightweight Phase Frensel Lenses (PFLs) in a virtual X-ray telescope with⇠1 km focal length and with⇠50 milli-arc second angular resolution. VTXO is formed by using precision formation flying of two SmallSats: a smaller OpticsSat that houses the PFLs and navigation beacons while a larger DetectorSat contains an X-ray camera, a precision start tracker, and the propulsion for the formation flying. The baseline flight dynamics uses a highly elliptical super synchronous orbit allow the formation to hold in an inertial frame around the 90,000 km apogee for 10 hours of the 32.5 hour orbit with nearly a year mission lifetime. VTXO’s fine angular resolution enables measuring the environments close to the central engines of bright compact X-ray sources. This X-ray imaging capability allows for the study of the effects of dust scattering near to the central objects such as Cyg X-3 and GX 5-1, for the search for jet structure near to the compact object in X-ray novae such as Cyg X-1 and GRS 1915+105, and for the search for structure in the termination shock of in the Crab pulsar wind nebula. The VTXO SmallSat and instrument designs, mission parameters, and science performance are described. VTXO development was supported as one of the selected 2018 NASA Astrophysics SmallSat Study (AS3) missions

John F Krizmanic↗

Rocket-ultraviolet imagery of the North America nebula

New ultraviolet imagery of NGC 7000 has been obtained in a sounding-rocket flight with an electrographic Schmidt camera which covers the 1230-2000 A wavelength range and has a higher angular resolution than the Apollo 16 imagery. The integrated brightness of NGC 7000 near 1450 A is unexpectedly high (three times the brightness of HD 199579 as measured by CHB), but as no emission lines were observed with a nebular spectrograph, it is concluded that the radiation observed in the UV image is nearly pure continuum. Comparison with the blue continuum image is not possible, as the latter image has dominant contributions due to night sky background, hydrogen recombination continuum, and possibly unresolved faint stars. It is suggested that the high UV brightness of NGC 7000 is due to the highly efficient dust scattering of stellar radiation.

Carruthers, G. R.↗

Lightweight and High-Resolution Single Crystal Silicon Optics for X-ray Astronomy

We describe an approach to building mirror assemblies for next generation X-ray telescopes. It incorporates knowledge and lessons learned from building existing telescopes, including Chandra, XMM-Newton, Suzaku, and NuSTAR, as well as from our direct experience of the last 15 years developing mirror technology for the Constellation-X and International X-ray Observatory mission concepts. This approach combines single crystal silicon and precision polishing, thus has the potential of achieving the highest possible angular resolution with the least possible mass. Moreover, it is simple, consisting of several technical elements that can be developed independently in parallel. Lastly, it is highly amenable to mass production, therefore enabling the making of telescopes of very large photon collecting areas.

X-ray optics↗