Search NASA⌕ Search

SEARCH · Search NASA

Results for “high spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Science support for the atmospheric trace molecule spectroscopy (ATMOS) experiment

The experiment is a satellite solar occultation interferometer spectrometer experiment under development for flight on Spacelab 3. Launch is expected in March 1985. ATMOS will provide high spectral resolution (0.02/cm) and high spatial resolution (2 km from Shuttle altitude) data over the spectral range from 2 micrometers to 16 micrometers. This region of the spectrum is rich in absorption features of major and minor trace gases which are critical to the understanding of the chemistry and physics of the Earth's upper atmosphere. The broad objectives of the ATMOS experiment are to: identify and measure, on a global scale, the volume mixing ratios of known and newly discovered molecular species; determine vertical profiles for these species; and provide spectral data on the atmosphere for use in optimizing the design of future instruments to monitor specific gases.

Rinsland, C. P.↗

Lidar Measurements of Tropospheric Wind Profiles with the Double Edge Technique

Research has established the importance of global tropospheric wind measurements for large scale improvements in numerical weather prediction. In addition, global wind measurements provide data that are fundamental to the understanding and prediction of global climate change. These tasks are closely linked with the goals of the NASA Earth Science Enterprise and Global Climate Change programs. NASA Goddard has been actively involved in the development of direct detection Doppler lidar methods and technologies to meet the wind observing needs of the atmospheric science community. A variety of direct detection Doppler wind lidar measurements have recently been reported indicating the growing interest in this area. Our program at Goddard has concentrated on the development of the edge technique for lidar wind measurements. Implementations of the edge technique using either the aerosol or molecular backscatter for the Doppler wind measurement have been described. The basic principles have been verified in lab and atmospheric lidar wind experiments. The lidar measurements were obtained with an aerosol edge technique lidar operating at 1064 nm. These measurements demonstrated high spatial resolution (22 m) and high velocity sensitivity (rms variances of 0.1 m/s) in the planetary boundary layer (PBL). The aerosol backscatter is typically high in the PBL and the effects of the molecular backscatter can often be neglected. However, as was discussed in the original edge technique paper, the molecular contribution to the signal is significant above the boundary layer and a correction for the effects of molecular backscatter is required to make wind measurements. In addition, the molecular signal is a dominant source of noise in regions where the molecular to aerosol ratio is large since the energy monitor channel used in the single edge technique measures the sum of the aerosol and molecular signals. To extend the operation of the edge technique into the free troposphere we have developed a variation of the edge technique called the double edge technique. In this paper a ground based aerosol double edge lidar is described and the first measurements of wind profiles in the free troposphere obtained with this lidar will be presented.

Gentry, Bruce M.↗

Hyperspectral Thermal Emission Spectrometer: Engineering Flight Campaign

The Hyperspectral Thermal Emission Spectrometer (HyTES) successfully completed its first set of engineering test flights. HyTES was developed in support of the Hyperspectral Infrared Imager (HyspIRI). HyspIRI is one of the Tier II Decadal Survey missions. HyTES currently provides both high spectral resolution (17 nm) and high spatial resolution (2-5m) data in the thermal infrared (7.5-12 micron) part of the electromagnetic spectrum. HyTES data will be used to help determine the optimum band positions for the HyspIRI Thermal Infrared (TIR) sensor and provide antecedent data for HyspIRI related studies.

HyTES↗

Joint Acceptance Attenuation Factor of Integrated Pressure with Unsteady Pressure-Sensitive Paint Measurements

The Unsteady Pressure-Sensitive Paint (uPSP) is widely used to measure the surface pressure of the scaled model in the wind tunnel tests. Compared to the conventional pressure transducers, uPSP has the advantage of high spatial resolution. With multiple high-speed cameras, the uPSP data collected with the camera pixels are mapped to the surface grid of the scaled model and converted to pressure. The shot noise, which is associated with the quantum processes both in the generation of the photons by the luminescent uPSP and in the conversion of the photons into electrons within the camera, is the dominant component of the noise in the uPSP measurement. The integrated pressure is usually computed as an area-weighted average of the uPSP measured pressures on the grid nodes of a user-defined patch. The effect of the shot noise is reduced in the integrated pressure; however, the measurement of the aerodynamic pressure is also attenuated. This paper discusses the Joint Acceptance Attenuation Factor (JAAF) of the integrated pressure with uPSP measurements. The JAAF is defined as the ratio of the auto or cross Power Spectral Density (PSD) of the integrated aerodynamic pressure on the patch to the average auto PSD of the aerodynamic pressure on the grid nodes of the patch. Under the assumption that the cross spectrum of the aerodynamic pressure can be described with the Corcos model, the closed-form formula of the JAAF is derived for the integrated pressure on rectangular patches via the summation of uPSP measurements on discrete grid nodes. The closed-form formula is verified via the integration of the pressure field of Corcos model over continuous areas. The properties of the JAAF with different parameters are presented and the applications in the comparison of the spectrum of the pressure transducers and uPSP measurements, which were collected in the NASA Space Launch System (SLS) tests with the 11-by-11-foot transonic wind tunnel at NASA Ames Research Center in December 2017 and September 2019 respectively, are also discussed. The work described in this paper is a part of NASA’s development of a new state-of-the-art uPSP capability in production wind tunnels. Funding was provided by the NASA Aerosciences Evaluation and Test Capabilities(AETC) Portfolio Office.

Unsteady Pressure-Sensitive Paint↗

Joint Acceptance Attenuation Factor of Integrated Pressure with Unsteady Pressure-Sensitive Paint Measurements

The Unsteady Pressure-Sensitive Paint (uPSP) is widely used to measure the surface pressure of scaled models in wind tunnel tests. Compared to the conventional pressure transducers, uPSP has the advantage of high spatial resolution. With multiple high-speed Complementary Metal Oxide Superconductor (CMOS) cameras, the uPSP data collected with the camera pixels are mapped to the surface grid of the scaled model and converted to pressure. The shot noise is the dominant component of the noise in the uPSP measurement. The integrated pressure is usually computed on the grid nodes of a user-defined patch. The effect of shot noise is reduced in the integrated pressure on the patch; however, the measurement of the aerodynamic pressure may also be attenuated by the decorrelation of the flow pressure field being measured. This paper discusses the Joint Acceptance Attenuation Factor (JAAF) of the integrated pressure with uPSP measurements. The JAAF, a function of frequency, is defined as the ratio of the Power Spectral Density (PSD) of the integrated aerodynamic pressure on the patch to the average PSD of the aerodynamic pressure on the grid nodes of the patch. In this paper, the JAAF is investigated for the integrated pressure on rectangular patches, whose edges are defined in the direction along the streamline or across the streamline. Based on the assumption that the surface pressure field can be described by the Corcos model, the closed-form formulas to compute the JAAFs of the integrated pressure on the discrete grid nodes of a rectangular patch and over the continuous area of a rectangular patch are derived respectively. It is shown that the JAAF of the integrated pressure over the continuous area of a rectangular patch is the limit of that on discrete nodes of the rectangular patch when the number of nodes in each row or column goes to infinity. The closed-form formulas of the JAAF derived in this paper, with estimated parameters of the model, are verified with the measurements of the uPSP and the conventional pressure transducer collected in the Space Launch System Ascent Unsteady Aerodynamics Test at NASA Ames Research Center in November 2017. The closed-form formulas of the JAAF of the integrated pressure on the rectangular patches, based on the Corcos model, provide an efficient method to estimate the attenuation of integration by the decorrelation of the flow pressure field and set references for the comparison of the spectrum of the integrated uPSP measurements and the conventional pressure transducer measurements. The work described in this paper is a part of NASA’s development of a new state-of-the-art uPSP capability in production wind tunnels. Funding was provided by the NASA Aerosciences Evaluation and Test Capabilities Portfolio Office.

acoustics↗

Joint Acceptance Attenuation Factor of Integrated Pressure with Unsteady Pressure-Sensitive Paint Measurements

The Unsteady Pressure-Sensitive Paint (uPSP) is widely used to measure the surface pressure of scaled models in wind tunnel tests. Compared to the conventional pressure transducers, uPSP has the advantage of high spatial resolution. With multiple high-speed Complementary Metal Oxide Superconductor (CMOS) cameras, the uPSP data collected with the camera pixels are mapped to the surface grid of the scaled model and converted to pressure. The shot noise is the dominant component of the noise in the uPSP measurement. The integrated pressure is usually computed on the grid nodes of a user-defined patch. The effect of shot noise is reduced in the integrated pressure on the patch; however, the measurement of the aerodynamic pressure may also be attenuated by the decorrelation of the flow pressure field being measured. This paper discusses the Joint Acceptance Attenuation Factor (JAAF) of the integrated pressure with uPSP measurements. The JAAF, a function of frequency, is defined as the ratio of the Power Spectral Density (PSD) of the integrated aerodynamic pressure on the patch to the average PSD of the aerodynamic pressure on the grid nodes of the patch. In this paper, the JAAF is investigated for the integrated pressure on rectangular patches, whose edges are defined in the direction along the streamline or across the streamline. Based on the assumption that the surface pressure field can be described by the Corcos model, the closed-form formulas to compute the JAAFs of the integrated pressure on the discrete grid nodes of a rectangular patch and over the continuous area of a rectangular patch are derived respectively. It is shown that the JAAF of the integrated pressure over the continuous area of a rectangular patch is the limit of that on discrete nodes of the rectangular patch when the number of nodes in each row or column goes to infinity. The closed-form formulas of the JAAF derived in this paper, with estimated parameters of the model, are verified with the measurements of the uPSP and the conventional pressure transducer collected in the Space Launch System Ascent Unsteady Aerodynamics Test at NASA Ames Research Center in November 2017. The closed-form formulas of the JAAF of the integrated pressure on the rectangular patches, based on the Corcos model, provide an efficient method to estimate the attenuation of integration by the decorrelation of the flow pressure field and set references for the comparison of the spectrum of the integrated uPSP measurements and the conventional pressure transducer measurements. The work described in this paper is a part of NASA’s development of a new state-of-the-art uPSP capability in production wind tunnels. Funding was provided by the NASA Aerosciences Evaluation and Test Capabilities Portfolio Office.

acoustics↗

Pushing the limits of spatial resolution with the Kuiper Airborne observatory

The study of astronomical objects at high spatial resolution in the far-IR is one of the most serious limitations to our work at these wavelengths, which carry information about the luminosity of dusty and obscured sources. At IR wavelengths shorter than 30 microns, ground based telescopes with large apertures at superb sites achieve diffraction-limited performance close to the seeing limit in the optical. At millimeter wavelengths, ground based interferometers achieve resolution that is close to this. The inaccessibility of the far-IR from the ground makes it difficult, however, to achieve complementary resolution in the far-IR. The 1983 IRAS survey, while extraordinarily sensitive, provides us with a sky map at a spatial resolution that is limited by detector size on a spatial scale that is far larger than that available in other wavelengths on the ground. The survey resolution is of order 4 min in the 100 micron bandpass, and 2 min at 60 microns (IRAS Explanatory Supplement, 1988). Information on a scale of 1' is available on some sources from the CPC. Deconvolution and image resolution using this database is one of the subjects of this workshop.

Lester, Daniel↗

High-energy, high-resolution x-ray imaging on the Trident short-pulse laser facility

With the completion of the Trident laser facility upgrade, 200 TW high-energy laser pulses are now capable of producing x-ray pulses with energies in the range of 15-40 keV, which will be used for high-spatial resolution radiography. A diagnostic suite is being developed on the laser system to investigate and characterize the x-ray emission from high-Z targets. This includes charge coupled device based single-photon counters, imaging plates, a high-energy electronic imager, spectral diagnostics, and optical and x-ray spot size diagnostics. We describe recent x-ray results from a commissioning campaign as well as describe the development and design of a high-energy spectrometer. X-ray radiographs taken at 22 keV with a spatial resolution of 25 {mu}m are a first demonstration on this facility of high-energy, high-spatial resolution capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of Best Low-Frequency Microwave Antenna Approach for Future High Resolution Measurements from Space

Microwave remote sensing measurements at L-band (~1.2-1.6 GHz) of geophysical parameters such as soil moisture will need to be at higher spatial resolution than current systems (SMOS/ SMAP/ Aquarius) in order to meet the requirements of land surface, ocean, and numerical weather prediction models in the near future, which will operate at ~9-15 km global grids and 1-3 km regional grids in the next few years. In order to make progress toward these needed spatial resolutions, advancements in technology are necessary which would lead to improved effective (i.e. equivalent) antenna size. An architecture trade study was conducted to quantitatively define the value and limits of different microwave technology paths, and to select the most appropriate path to achieve the high spatial resolution required by science in the future without sacrificing performance, accuracy, and global coverage.

soil moisture↗

A HIGH-RESOLUTION SURVEY OF H I ABSORPTION TOWARD THE CENTRAL 200 pc OF THE GALACTIC CENTER

We present an H I absorption survey of the central 250 pc of the Galaxy. Very Large Array observations were made at 21 cm in the DnC and CnB configurations and have a resolution of {approx}15'' (0.6 pc at the Galactic center (GC) distance) and a velocity resolution of {approx}2.5 km s{sup -1}. This study provides H I data with high spatial resolution, comparable with the many high-resolution observations which have been made of GC sources over the past 10 years. Here we present an overview of the H I absorption toward {approx}40 well-known continuum sources and a detailed comparison of the ionized, atomic, and molecular components of the interstellar medium for the Sgr B, Radio Arc, and Sgr C regions. In these well-known regions, the atomic gas appears to be closely correlated in both velocity and distribution to the ionized and molecular gas, indicating that it resides in photodissociation regions related to the H II regions in the GC. Toward the majority of the radio continuum sources, H I absorption by the 3 kpc arm is detected, constraining these sources to lie beyond a 5 kpc distance in the Galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-AB-BRB-12: Nanoscintillator Fiber-Optic Detector System for Microbeam Radiation Therapy Dosimetry

Purpose: Microbeam Radiation Therapy (MRT) is an experimental radiation therapy that has demonstrated a higher therapeutic ratio than conventional radiation therapy in animal studies. There are several roadblocks in translating the promising treatment technology to clinical application, one of which is the lack of a real-time, high-resolution dosimeter. Current clinical radiation detectors have poor spatial resolution and, as such, are unsuitable for measuring microbeams with submillimeter-scale widths. Although GafChromic film has high spatial resolution, it lacks the real-time dosimetry capability necessary for MRT preclinical research and potential clinical use. In this work we have demonstrated the feasibility of using a nanoscintillator fiber-optic detector (nanoFOD) system for real-time MRT dosimetry. Methods: A microplanar beam array is generated using a x-ray research irradiator and a custom-made, microbeam-forming collimator. The newest generation nanoFOD has an effective size of 70 µm in the measurement direction and was calibrated against a kV ion chamber (RadCal Accu-Pro) in open field geometry. We have written a computer script that performs automatic data collection with immediate background subtraction. A computer-controlled detector positioning stage is used to precisely measure the microbeam peak dose and beam profile by translating the stage during data collection. We test the new generation nanoFOD system, with increased active scintillation volume, against the previous generation system. Both raw and processed data are time-stamped and recorded to enable future post-processing. Results: The real-time microbeam dosimetry system worked as expected. The new generation dosimeter has approximately double the active volume compared to the previous generation resulting in over 900% increase in signal. The active volume of the dosimeter still provided the spatial resolution that meets the Nyquist criterion for our microbeam widths. Conclusion: We have demonstrated that real-time dosimetry of MRT microbeams is feasible using a nanoscintillator fiber-optic detector with integrated positioning system.

60 APPLIED LIFE SCIENCES↗

EVOLUTION OF GASEOUS DISK VISCOSITY DRIVEN BY SUPERNOVA EXPLOSION. II. STRUCTURE AND EMISSIONS FROM STAR-FORMING GALAXIES AT HIGH REDSHIFT

High spatial resolution observations show that high-redshift galaxies are undergoing intensive evolution of dynamical structure and morphologies displayed by the H{alpha}, H{beta}, [O III], and [N II] images. It has been shown that supernova explosion (SNexp) of young massive stars during the star formation epoch, as kinetic feedback to host galaxies, can efficiently excite the turbulent viscosity. We incorporate the feedback into the dynamical equations through mass dropout and angular momentum transportation driven by the SNexp-excited turbulent viscosity. The empirical Kennicutt-Schmidt law is used for star formation rates (SFRs). We numerically solve the equations and show that there can be intensive evolution of structure of the gaseous disk. Secular evolution of the disk shows interesting characteristics: (1) high viscosity excited by SNexp can efficiently transport the gas from 10 kpc to {approx}1 kpc forming a stellar disk whereas a stellar ring forms for the case with low viscosity; (2) starbursts trigger SMBH activity with a lag of {approx}10{sup 8} yr depending on SFRs, prompting the joint evolution of SMBHs and bulges; and (3) the velocity dispersion is as high as {approx}100 km s{sup -1} in the gaseous disk. These results are likely to vary with the initial mass function (IMF) that the SNexp rates rely on. Given the IMF, we use the GALAXEV code to compute the spectral evolution of stellar populations based on the dynamical structure. In order to compare the present models with the observed dynamical structure and images, we use the incident continuum from the simple stellar synthesis and CLOUDY to calculate emission line ratios of H{alpha}, H{beta}, [O III], and [N II], and H{alpha} brightness of gas photoionized by young massive stars formed on the disks. The models can produce the main features of emission from star-forming galaxies. We apply the present model to two galaxies, BX 389 and BX 482 observed in the SINS high-z sample, which are bulge and disk-dominated, respectively. Two successive rings independently evolving are able to reproduce the main dynamical and emission properties of the two galaxies, such as the Baldwin-Phillips-Terlevich diagram, the relation between line ratios, and H{alpha} brightness. The observed relation between turbulent velocity and the H{alpha} brightness can be explained by the present model. High viscosity excited by SNexp is able to efficiently transport the gas into a bulge to maintain high SFRs or to form a stellar ring close enough to the bulge so that it immigrates into the bulge of its host galaxy. This leads to a fast growing bulge. Implications and future work of the present models have been extensively discussed for galaxy formation in high-z universe.

79 ASTRONOMY AND ASTROPHYSICS↗

The Analysis of Using Satellite Soil Moisture Observations for Flood Detection, Evaluating Over the Thailand’s Great Flood of 2011

A flood monitoring and warning system provides critical information that can protect property and save lives. A basin-scale flood monitoring system requires an effective observation platform that offers extensive ground coverage of flood conditions, low latency, and high spatiotemporal resolution. While satellite imagery offers substantial spatial flood extent in detail due to its high spatial resolution, the coarse temporal resolution and cloud obstruction limit its near real-time application. Daily soil moisture data derived from satellite sensors at a scale of a few km can be used to monitor extreme wet surface conditions arising in flood occurrences. This study analyses the flood detection capabilities of several sources of soil moisture information, including the Soil Moisture and Ocean Salinity mission (SMOS), the Advanced Microwave Scanning Radiometer on EOS (AMSR-E), the Advanced SCATterometer (ASCAT) on MetOp, the Global Land Data Assimilation System (GLDAS), and the WaterGAP Global Hydrology Model (WGHM). In addition to soil moisture, the analysis includes measurements of surface reflectance from the Moderate Resolution Imaging Spectroradiometer (MODIS), precipitation measurements from the Tropical Rainfall Measuring Mission (TRMM), and terrestrial water storage estimates from the Gravity Recovery And Climate Experiment (GRACE) as proxies for flood inundations. The analysis was conducted over the Chao Phraya River Basin (CPB) in Thailand, where the Great Flood of 2011 led to one of the most significant economic losses in the country's history. Satellite-derived soil moisture exhibits a stronger correlation with the flood inundations than the precipitation, model-derived soil moisture, and terrestrial water storage data. SMOS soil moisture observation agrees best with the MODIS-derived flood extent/occurrence, both in terms of spatial distribution and timing, and providing approximated flood lead-time of one week or longer. A neural network constructed from SMOS and MODIS data is used to predict flood intensity/occurrence (given soil moisture input) with a predicted time window from eight days to thirty-two days. The short-term prediction (e.g., eight days) achieves the highest accuracy with an averaged recovery rate of approximately 60% (correlation coefficient). This study's results suggest a potential application of satellite soil moisture data in assisting flood monitoring and warning systems.

Satellite soil moisture↗

A silicon strip detector dose magnifying glass for IMRT dosimetry

Purpose: Intensity modulated radiation therapy (IMRT) allows the delivery of escalated radiation dose to tumor while sparing adjacent critical organs. In doing so, IMRT plans tend to incorporate steep dose gradients at interfaces between the target and the organs at risk. Current quality assurance (QA) verification tools such as 2D diode arrays, are limited by their spatial resolution and conventional films are nonreal time. In this article, the authors describe a novel silicon strip detector (CMRP DMG) of high spatial resolution (200 {mu}m) suitable for measuring the high dose gradients in an IMRT delivery. Methods: A full characterization of the detector was performed, including dose per pulse effect, percent depth dose comparison with Farmer ion chamber measurements, stem effect, dose linearity, uniformity, energy response, angular response, and penumbra measurements. They also present the application of the CMRP DMG in the dosimetric verification of a clinical IMRT plan. Results: The detector response changed by 23% for a 390-fold change in the dose per pulse. A correction function is derived to correct for this effect. The strip detector depth dose curve agrees with the Farmer ion chamber within 0.8%. The stem effect was negligible (0.2%). The dose linearity was excellent for the dose range of 3-300 cGy. A uniformity correction method is described to correct for variations in the individual detector pixel responses. The detector showed an over-response relative to tissue dose at lower photon energies with the maximum dose response at 75 kVp nominal photon energy. Penumbra studies using a Varian Clinac 21EX at 1.5 and 10.0 cm depths were measured to be 2.77 and 3.94 mm for the secondary collimators, 3.52 and 5.60 mm for the multileaf collimator rounded leaf ends, respectively. Point doses measured with the strip detector were compared to doses measured with EBT film and doses predicted by the Philips Pinnacle treatment planning system. The differences were 1.1%{+-}1.8% and 1.0%{+-}1.6%, respectively. They demonstrated the high temporal resolution capability of the detector readout system, which will allow one to investigate the temporal dose pattern of IMRT and volumetric modulated arc therapy (VMAT) deliveries. Conclusions: The CMRP silicon strip detector dose magnifying glass interfaced to a TERA ASIC DAQ system has high spatial and temporal resolution. It is a novel and valuable tool for QA in IMRT dose delivery and for VMAT dose delivery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gradients in giant branch morphology in the core of 47 Tucanae

I describe an algorithm which uses the high spatial resolution of the Hubble Space Telescope to complement the high spatial-to-noise, approximately symmetric point response function, relatively large spatial coverage, and standard filters available from ground based images of crowded fields. Applying this technique to the central regions of the globular cluster 47 Tucanae, I find that the morphology of the giant branch in the core is significantly different from that in more distant regions (r approximately equals 5 to 10 core radii) of the cluster. In particular, there appear to be fewer bright giants in the core, along with an enhanced `asymptotic giant branch' (AGB) sequence. Depletion of giants has been observed in the cores of other dense clusters, and may be due to `stripping' of large stars by stellar encounters and/or mass transfer in binary systems. Central concentrations of true asymptotic giant branch stars are not expected to result from dynamical processes; possibly some of these stars may be evolved blue stragglers.

Bailyn, Charles D.↗

HYBRID simulations of diffraction-limited focusing with Kirkpatrick-Baez mirrors for a next-generation In Situ hard X-ray nanoprobe

Next-generation hard X-ray nanoprobe beamlines such as the In Situ Nanoprobe (ISN) beamline being planned at the Advanced Photon Source aim at providing very high spatial resolution while also enabling very high focused flux, to study complex materials and devices using fast, multidimensional imaging across many length scales. The ISN will use diffractive optics to focus X-rays with a bandpass of ΔE/E = 10 –4 into a focal spot of 20 nm or below. Reflective optics in Kirkpatrick-Baez geometry will be used to focus X-rays with a bandpass as large as ΔE/E = 10 –2 into a focal spot of 50 nm. Diffraction-limited focusing with reflective optics is achieved by spatial filtering and use of a very long, vertically focusing mirror. Furthermore, to quantify the performance of the ISN beamline, we have simulated the propagation of both partially and fully coherent wavefronts from the undulator source, through the ISN beamline and into the mirror-based focal spot. Simulations were carried out using the recently developed software “HYBRID.”

43 PARTICLE ACCELERATORS↗

Passive/active Microwave Soil Moisture Change Disaggregation Using Smapvex12 Data

The SMAPVEX12 (Soil Moisture Active Passive (SMAP) Validation Experiment 2012) experiment was conducted during June-July 2012 in Manitoba, Canada with the goal of collecting remote sensing data and ground measurements for the development and testing of soil moisture retrieval algorithms under varying vegetation and soil conditions for the SMAP satellite. The aircraft based soil moisture data provided by the passive/active microwave sensor PALS (Passive and Active L-band System) has a nominal spatial resolution of 1600 m. However, this resolution is not compatible with agricultural, meteorological and hydrological studies that require high spatial resolutions and this issue can be solved by soil moisture disaggregation. The soil moisture disaggregation algorithm integrates radiometer soil moisture retrievals and high-resolution radar observations and it can provide soil moisture estimates at a finer scale than the radiometer data alone. In this study, a change detection algorithm was used for disaggregation of coarse resolution passive microwave soil moisture retrievals with radar backscatter coefficients obtained from the higher spatial resolution UAVSAR (Unmanned Air Vehicle Synthetic Aperture Radar) at crop field scale. The accuracy of the disaggregated change in soil moisture was evaluated using ground based soil moisture measurements collected during SMAPVEX12 campaign. The results showed that soil moisture spatial variabilities were better characterized by the disaggregated change in soil moisture estimates at 5 m / 800 m resolution as well as good agreement with in situ measurements. It also showed that VWC (Vegetation Water Content) did not have a big impact on disaggregation algorithm performance, with R2 of the disaggregated results ranging 0.628-0.794. The 5 m and 800m resolution disaggregated soil moisture did no show significant difference in statistical performance variables.

Radar Backscatter↗