Search NASA⌕ Search

SEARCH · Search NASA

Results for “importance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Ultra-high speed imaging and DIC for explosive system observation.

Digital image correlation (DIC) and the tremendous advances in optical imaging are beginning to revolutionize explosive and high-strain rate measurements. This paper presents results obtained from metallic hemispheres expanded at detonation velocities. Important aspects of sample preparation and lighting of the image will be presented that are key considerations in obtaining images for DIC with frame rates at 1-million frames/second. Quantitative measurements of the case strain rate, expansion velocity and deformation will be presented. Furthermore, preliminary estimations of the measurement uncertainty will be discussed with notes on how image noise and contrast effect the measurement of shape and displacement. The data are then compared with analytical representations of the experiment.

99 GENERAL AND MISCELLANEOUS↗

The radiolysis of CMPO: effects of acid, metal complexation and alpha vs. gamma radiation

Abstract The group actinide/lanthanide complexing agent octylphenylcarbamoylmethyl phosphine oxide (CMPO) has been examined for its radiation stability by measuring the kinetics of its reactions with free radicals in both the aqueous and organic phases for the free and metal-complexed ligand, identifying its degradation products for both alpha and gamma irradiation, measuring the effects on solvent extraction performance, and measuring the G-values for its degradation under various conditions. This includes the G-values for CMPO in the absence of, and in contact with the acidic aqueous phase, where it is shown that the acidic aqueous phase provides radio-protection for this ligand. It was found that both solvent and metal complexation affect the kinetics of the reaction of the •NO3 radical, a product of HNO3 radiolysis, with CMPO. For example, CMPO complexed with lanthanides has a rate constant for this reaction an order of magnitude higher than for the free ligand, and the reaction for the free ligand in the organic phase is about three times faster than in the aqueous phase. In steady state radiolysis kinetics it was determined that HNO3, although not NO3- anion, provides radio-protection to CMPO, with the G-value for its degradation decreasing with increasing acidity, until it was almost completely suppressed by irradiation in contact with 5 M HNO3. The same degradation products were produced by irradiation with alpha and gamma-sources, except that the relative abundances of these products varied. For example, the product of C-C bond scission was produced only in low amounts for gamma-radiolysis, but it was an important product for samples irradiated with a He ion beam. These results are compared to the new data appearing in the literature on DGA radiolysis, since CMPO and the DGAs both contain the amide functional group.

CMPO↗

Field Test to Evaluate Deep Borehole Disposal.

The U.S. Department of Energy (DOE) has embarked on the Deep Borehole Field Test (DBFT), which will investigate whether conditions suitable for disposal of radioactive waste can be found at a depth of up to 5 km in the earth’s crust. As planned, the DBFT will demonstrate drilling and construction of two boreholes, one for initial scientific characterization, and the other at a larger diameter such as could be appropriate for waste disposal (the DBFT will not involve radioactive waste). A wide range of geoscience activities is planned for the Characterization Borehole, and an engineering demonstration of test package emplacement and retrieval is planned for the larger Field Test Borehole. Characterization activities will focus on measurements and samples that are important for evaluating the long-term isolation capability of the Deep Borehole Disposal (DBD) concept. Engineering demonstration activities will focus on providing data to evaluate the concept’s operational safety and practicality. Procurement of a scientifically acceptable DBFT site and a site management contractor is now underway. The concept of deep borehole disposal (DBD) for radioactive wastes is not new. It was considered by the National Academy of Science (NAS 1957) for liquid waste, studied in the 1980’s in the U.S. (Woodward–Clyde 1983), and has been evaluated by European waste disposal R&D programs in the past few decades (for example, Grundfelt and Crawford 2014; Grundfelt 2010). Deep injection of wastewater including hazardous wastes is ongoing in the U.S. and regulated by the Environmental Protection Agency (EPA 2001). The DBFT is being conducted with a view to use the DBD concept for future disposal of smaller-quantity, DOE-managed wastes from nuclear weapons production (i.e., Cs/Sr capsules and granular solid wastes). However, the concept may also have broader applicability for nations that have a need to dispose of limited amounts of spent fuel from nuclear power reactors. For such nations the cost for disposing of volumetrically limited waste streams could be lower than mined geologic repositories.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Cost of (In-) Accurate Waste Characterization in the U.S. Nuclear Power Industry - 20066

Proper disposal of waste has never been a human priority. Our history is full of examples of throwing away things with minimal effort or thought to consequence. That is until disease or toxicity become apparent and we realize we need to change. Unfortunately, we almost never have all the information we need at the time we make decisions. In addition to the technical and scientific issues, profits and politics are also factors. Newton's third law also applies to politics and so for every policy (action) put in place, there will be (opposite reaction) forces in play to push back against it. These forces are seldom balanced and so the reaction to the discovery of harm is to over-correct and destroy the benefit to be had. This of course causes those who want the benefit, or profit from it, to work to undermine or repeal those measures put in place to eliminate the harm. The issue is exacerbated when the problem to be solved is highly technical and at the edge of our science so that the harm and benefit cannot be easily or accurately quantified. At these times, reason often goes out the window and our decision makers are influenced by either greed or fear as these emotions are much easier to stoke. Those of us in the middle, with the charge to 'do the right thing for the least cost', are therefore frequently constrained and forced into actions that are neither technically the right thing to do and not cost effective. The cost of radioactive waste disposal is based on the concentrations of various radioisotopes in the waste. Some of these isotopes are relatively easy to quantify and some are not. Most laboratory methods for quantification are limited in the amount of activity that can be present during the measurement process. Current nuclear plants were not designed with the idea that taking truly representative waste samples would be important. The limits used to define waste class and therefore cost are precisely defined but the methods for determining those concentrations are far less precise. Improving the accuracy of radioactivity concentrations in waste and having consistent and reasonable oversight can reduce waste costs through active management of the process. So what can we do about it? Science may provide an answer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PACKAGING AND TRANSPORTATION OF NEPTUNIUM OXIDE

The Savannah River Site's HB-Line Facility completed a campaign in which fifty (50) cans of neptunium oxide were produced and shipped to the Idaho National Laboratory in the 9975 shipping container. This shipping campaign involved the addition of neptunium oxide to the 9975 Safety Analysis Report for Packaging (SARP) as a new content and subsequently a Letter of Amendment to the SARP content table. This paper will address the proper steps which should be taken to add a new content table to a SARP. It will also address the importance of product sampling and understanding the material shipping requirements of a SARP.

42 ENGINEERING↗

Solving Complex Radioactive Decay Chains for Future Assessment and Cleanup Decisions - 17046

In support of U.S. Environmental Protection Agency's on-line calculators for risk and dose assessment, a decay chain tool was developed to address the need to understand how radionuclide activity changes with time as the activity measured in the past will be different from current and future levels. When a radionuclide decays, its activity decreases exponentially as a function of time transforming into a different atom - a decay product. The atoms keep transforming to new decay products until they reach a stable state and are no longer radioactive. The series of decay products created to reach this balance is called the decay chain. For radionuclide chains, the daughter products can have significant implications in dosimetry and remediation. Thus, risk assessors evaluating sites with radioactive contamination need to plan for future progeny ingrowth, in addition to sampled radionuclides. These are important considerations for risk quantification during the characterization and cleanup plans, particularly when sampling may have occurred years before the remediation cleanup work begins. If a radionuclide half-life and current activity are known, then hand-calculating the future activity is straightforward. However, calculating the ingrowth of progeny quickly becomes cumbersome for longer chains such as the Thorium-232 decay series. For the more complex chains where many daughters are formed, possibly with multiple branches, this calculation involves solving a complex set of simultaneous differential equations known as the Bateman Equation. The Decay Chain Activity Projection Tool calculates the activity of radionuclides and their progeny as a function of time. This tool currently uses a combination of Perl, JavaScript, Plot.ly, and jQuery to automatically construct the radionuclide decay chains, solve the resulting Bateman Equation, and provide the user with tabular solution output and plots. Additional software may be used as development advances. The risk assessor can then use the data for exposure assessment and cleanup decisions without further costly sampling. The benefits of providing this calculator are to prevent overestimation of risk due to decay of the parent isotope and to avoid underestimation of risk due to ingrowth of progeny more toxic than the parent. Graphs are provided to show the simultaneous decay rates and ingrowth, as well as tabular output at time-point T and all the decay half-life intervals. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-T-220: Validation of Hounsfield Unit-To-Stopping Power Ratio Calibration Used for Dose Calculation in Proton Radiotherapy

Purpose: To validate the stoichiometric calibration of the Hounsfield Unit (HU) to Stopping Power Ratio (SPR) calibration used to commission a commercial treatment planning system (TPS) for proton radiotherapy dose calculation. Methods and Materials: The water equivalent thickness (WET) of several individual pig tissues (lung, fat, muscle, liver, intestine, rib, femur), mixed tissue samples (muscle/rib, ice/femur, rib/air cavity/muscle), and an intact pig head were measured with a multi-layer ionization chamber (MLIC). A CT scan of each sample was obtained and imported into a commercial TPS. The WET calculated by the TPS for each tissue sample was compared to the measured WET value to determine the accuracy of the HU-to-SPR calibration curve used by the TPS to calculate dose. Results: The WET values calculated by the TPS showed good agreement (< 2.0%) with the measured values for bone and all soft tissues except fat (3.1% difference). For the mixed tissue samples and the intact pig head measurements, the difference in the TPS and measured WET values all agreed to within 3.5%. In addition, SPR values were calculated from the measured WET of each tissue, and compared to SPR values of reference tissues from ICRU 46 used to generate the HU-to-SPR calibration for the TPS. Conclusion: For clinical scenarios where the beam passes through multiple tissue types and its path is dominated by soft tissues, we believe using an uncertainty of 3.5% of the planned beam range is acceptable to account for uncertainties in the TPS WET determination.

60 APPLIED LIFE SCIENCES↗

Modelling, simulation and sounding of cometary nuclei; Proceedings of the International Workshop, Cagliari, Italy, May 28-30, 1991

The present workshop on the modeling, simulation, and sounding of cometary nuclei discusses the Rosetta comet-nucleus sample return mission, the importance of comet models in the design of the Rosetta mission, the challenge of sample acquisition in a cometary environment, and a simulation of Rosetta on-comet operations. Attention is given to HST observations of the inner coma of Comet Levy 1990c, cometary coma particulate modeling for the Rosetta mission aphelion rendezvous, recent gas flux modeling and applications of cometary nuclei, and the 3D time-dependent modeling of comet nucleus surface layers. Topics addressed include models of cometary nuclei and future space mission, the composition of cometary materials, experiments with cometary analogs at the DLR, and crust formation in cometary analogs. Also considered are gaseous products from VUV photolysis of cometary solids, cosmic ray modification of organic cometary matter as simulated by cyclotron irradiation, and KOSI comet simulation experiments.

Source record↗

The Scientific Importance of Returning Airfall Dust as a Part of Mars Sample Return (MSR)

Dust transported in the martian atmosphere is of intrinsic scientific interest and has relevance for the planning of human missions in the future. The MSR Campaign, as currently designed, presents an important opportunity to return serendipitous, airfall dust. The tubes containing samples collected by the Perseverance rover would be placed in cache depots on the martian surface perhaps as early as 2023–24 for recovery by a subsequent mission no earlier than 2028–29, and possibly as late as 2030–31. Thus, the sample tube surfaces could passively collect dust for multiple years. This dust is deemed to be exceptionally valuable as it would inform our knowledge and understanding of Mars' global mineralogy, surface processes, surface-atmosphere interactions, and atmospheric circulation. Preliminary calculations suggest that the total mass of such dust on a full set of tubes could be as much as 100 mg and, therefore, sufficient for many types of laboratory analyses. Two planning steps would optimize our ability to take advantage of this opportunity: (1) the dust-covered sample tubes should be loaded into the Orbiting Sample container (OS) with minimal cleaning and (2) the capability to recover this dust early in the workflow within an MSR Sample Receiving Facility (SRF) would need to be established. A further opportunity to advance dust/atmospheric science using MSR, depending upon the design of the MSR Campaign elements, may lie with direct sampling and the return of airborne dust.

Monica M. Grady↗

The Importance of Primary Martian Surface and Airfall Dust Sample Return for Toxicological Hazard Evaluations for Human Exploration

Manned missions to the Moon highlight a major hazard for future human exploration of the Moon and beyond: surface dust. Not only did the dust cause mechanical and structural integrity issues with the suits, the dust 'storm' generated upon reentrance into the crew cabin caused "lunar hay fever" and "almost blindness" . It was further reported that the allergic response to the dust worsened with each exposure. Due to the prevalence of these high exposures, the Human Research Roadmap developed by NASA identifies the Risk of Adverse Health and Performance Effects of Celestial Dust Exposure as an area of concern. Extended human exploration will further increase the probability of inadvertent and repeated exposures to celestial dusts. Going forward, hazard assessments of celestial dusts will be determined through sample return efforts prior to astronaut deployment.

Harrington, A. D.↗

Using low volume eDNA methods to sample pelagic marine animal assemblages

Environmental DNA (eDNA) is an increasingly useful method for detecting pelagic animals in the ocean but typically requires large water volumes to sample diverse assemblages. Ship-based pelagic sampling programs that could implement eDNA methods generally have restrictive water budgets. Studies that quantify how eDNA methods perform on low water volumes in the ocean are limited, especially in deep-sea habitats with low animal biomass and poorly described species assemblages. Using 12S rRNA and COI gene primers, we quantified assemblages comprised of micronekton, coastal forage fishes, and zooplankton from low volume eDNA seawater samples (n = 436, 380–1800 mL) collected at depths of 0–2200 m in the southern California Current. We compared diversity in eDNA samples to concurrently collected pelagic trawl samples (n = 27), detecting a higher diversity of vertebrate and invertebrate groups in the eDNA samples. Differences in assemblage composition could be explained by variability in size-selectivity among methods and DNA primer suitability across taxonomic groups. The number of reads and amplicon sequences variants (ASVs) did not vary substantially among shallow (<200 m) and deep samples (>600 m), but the proportion of invertebrate ASVs that could be assigned a species-level identification decreased with sampling depth. Using hierarchical clustering, we resolved horizontal and vertical variability in marine animal assemblages from samples characterized by a relatively low diversity of ecologically important species. Low volume eDNA samples will quantify greater taxonomic diversity as reference libraries, especially for deep-dwelling invertebrate species, continue to expand.

59 BASIC BIOLOGICAL SCIENCES↗

Real sample temperature: a critical issue in the experiments of nuclear resonant vibrational spectroscopy on biological samples

There are several practical and intertangled issues which make the experiments of nuclear resonant vibrational spectroscopy (NRVS) on biological samples difficult to perform. The sample temperature is one of the most important issues. In NRVS the real sample temperatures can be very different from the readings on the temperature sensors. In this study the following have been performed: (i) citing and analyzing various existing NRVS data to assess the real sample temperatures during the NRVS measurements and to understand their trends with the samples’ loading conditions; (ii) designing several NRVS measurements with (Et 4 N)[FeCl 4 ] to verify these trends; and (iii) proposing a new sampleloading procedure to achieve significantly lower real sample temperatures and to balance among the intertangled experimental issues in biological NRVS measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel Biomedical Device Utilizing Light-Emitting Nanostructures Developed

Sketches and chemical diagrams of state-of-the-art device and novel proposed device are presented. Current device uses a diode laser that emits into a fluorescent fluid only one wavelength and a photodetector diode that detects only one wavelength. Only one type of bacteria can be detected. The proposed device uses a quantum dot array that emits into a fluorescent fluid multiple wavelengths and an NIR 512 spectrometer that scans 0.8- to 1.7-mm wavelengths. Hundreds of different bacteria and viruses can be detected. A novel biomedical device is being developed at the NASA Glenn Research Center in cooperation with the University of Michigan. This device uses nano-structured quantum dots that emit light in the near-infrared (IR) region. The nanostructured quantum dots are used as a source and excite fluorochrome polymers coupled with antibodies that seek out and attach to specific bacteria and viruses. The fluorochrome polymers/antibodies fluoresce at specific wavelengths in the near-IR spectrum, but these wavelengths are offset from the excitation wavelength and can be detected with a tunable spectrometer. The device will be used to detect the presence of viruses and bacteria in simple fluids and eventually in more complex fluids, such as blood. Current state-of-the-art devices are limited to single bacteria or virus detection and a considerable amount of time and effort is required to prepare samples for analysis. Most importantly, the devices are quite large and cumbersome, which prohibits them from being used on the International Space Station and the space shuttles. This novel device uses nanostructured quantum dots which, through molecular beam epitaxy and highly selective annealing processes, can be developed into an illumination source that could potentially generate hundreds of specific wavelengths. As a result, this device will be able to excite hundreds of antibody/fluorochrome polymer combinations, which in turn could be used to detect hundreds of bacteria and viruses in fluids. A novel sample preparation technique that exploits micromembrane filtration and centrifugation methods has been developed for this device. The technique greatly reduces the time required to prepare the sample and the amount of sample needed to perform an accurate and comprehensive analysis. Last, and probably most important, because of the nano-light-emitting source and the novel sample preparation technique, the overall size of the device could be reduced dramatically. This device will serve as a nanoscale lab-on-a-chip for in situ microorganism detection and will enable tests to be performed on a time scale of minutes rather than days. Thus, it is ideally suited for monitoring the environmental conditions onboard the International Space Station and the space shuttles, thereby enhancing the safety of the astronauts. In addition, the device has important commercial applications, such as detecting the presence of bacteria and viruses in water at food- and beverage-processing centers, water treatment plants, and restaurants. Also, this technology has the potential to be used to detect bacteria and viruses in more complex fluids, such as blood--which in all likelihood would revolutionize blood analysis as it is performed today. This project was made possible through the Director's Discretionary Fund and is ongoing. In addition, this project provides funding to Dr. Rachel Goldman of the University of Michigan for the research and development of nanostructured quantum dots.

Scardelletti, Maximilian C.↗

Proposed Science Requirements and Acquisition Priorities for the First Mars Sample Return

A sample return mission is an important next step in the exploration of Mars. The first sample return should come early in the program time-line because the science derived from earth-based analyses of samples provides crucial "ground truth" needed for further exploration planning, enhancement of remote measurements, and achieving science goals and objectives that include: (1) the search for environments that may support life and any indicators of the past or present existence of life, (2) understanding the history of water and climate on Mars, (3) understanding the evolution of Mars as a planet. Returned samples from Mars will have unique value because they can be studied by scientists worldwide using the most powerful analytical instruments available. Furthermore, returned Mars samples can be preserved for studies by future generations of scientists using new techniques and addressing new issues in Mars science. To ensure a high likelihood of success, the first sample return strategy should be simple and focused. We outline a fundamental set of sample requirements and acquisition priorities for Mars sample return.

Agee, C. B.↗

Intern Designed Modules for Conducting Potential Microgravity Solidification Experiments Aboard the International Space Station

MMaJIC (Microgravity Materials Joining Investigation Chamber) is a modular experiment chamber for performing materials science investigations. MMaJIC was initially designed to provide a controlled and sealed test environment to accommodate a wide variety of soldering and brazing experiments. However, its modular cartridge design is well suited to easily conduct any number and variety of science experiments. SoLIDD (Solid Liquid Interface Directional Device) is an apparatus for conducting directional solidification experiments with low melting temperature alloys. It has capability for varying the sample’s temperature gradient and growth velocity thus ensuring microstructural development under controlled conditions. ICED-T (Interface Control Experiment with Directional Translation) is an apparatus that conducts directional solidification experiments of transparent materials such that direct observation/recording of the advancing solid/liquid interface can be made. Currently, it is a functional breadboard that consists of the components mounted to a surface that allows the sample to be placed in an upright position. Orientation of the experiment (solid on the bottom, liquid on top) is important during testing ground samples to maintain stability. Ultimately, the goal of MMaJIC, SoLIDD and ICED-T is to conduct successful ground tests and then be re-configured for eventual use by aboard the ISS.

McElderry, Justin↗

Thermal Design, Analysis, and Sensitivity of a Sample Tube on the Martian Surface

NASA will launch a rover to Mars in 2020 to collect and cache samples of Martian rocks and regolith for potential return to Earth on a future mission. The collected samples will be placed in tubes, hermetically sealed, and deposited on the surface of Mars for a period of up to 10 years. Preventing the deposited samples from overheating is an important consideration in order to ensure their scientific integrity. The samples are required to remain below 60 °C, however there is a goal to keep them below 40 °C. This temperature requirement is challenging, considering that the maximum surface temperature of Mars is 38 °C and the tube must be thermally controlled through only passive means. As a result, a significant effort has been made to design a tube to contain the samples and investigate innovative tube surface treatments that maintain proper sample temperatures without significant adverse effects of sample contamination. The tube uses a specialized aluminum oxide coating to prevent overheating on the Martian surface. The maximum predicted tube temperature is relatively insensitive to local thermal inertia, ground contact, and ground slope, but is very sensitive to landing site latitude and dust deposition. The maximum predicted sample temperature in the +/- 30° landing latitude range with worst case assumptions is 54 °C, but many of the potential landing sites have significantly cooler maximum predicted sample temperatures. This paper describes the thermal design, analysis, and sensitivity studies performed on the sample tubes and also discusses operational considerations.

Novak, Keith↗

DO BARS DRIVE SPIRAL DENSITY WAVES?

We present deep near-infrared K{sub s} -band Anglo-Australian Telescope Infrared Imager and Spectrograph observations of a selected sample of nearby barred spiral galaxies, including some with the strongest known bars. The sample covers a range of Hubble types from SB0{sup -} to SBc. The goal is to determine if the torque strengths of the spirals correlate with those of the bars, which might be expected if the bars actually drive the spirals as has been predicted by theoretical studies. This issue has implications for interpreting bar and spiral fractions at high redshift. Analysis of previous samples suggested that such a correlation exists in the near-infrared, where effects of extinction and star formation are less important. However, the earlier samples had only a few excessively strong bars. Our new sample largely confirms our previous studies, but still any correlation is relatively weak. We find two galaxies, NGC 7513 and UGC 10862, where there is only a weak spiral in the presence of a very strong bar. We suggest that some spirals probably are driven by their bars at the same pattern speed, but that this may be only when the bar is growing or if there is abundant gas and dissipation.

79 ASTRONOMY AND ASTROPHYSICS↗