Search NASA⌕ Search

SEARCH · Search NASA

Results for “ion beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Benchmarking of X‐Ray Fluorescence Microscopy with Ion Beam Implanted Samples Showing Detection Sensitivity of Hundreds of Atoms

Abstract Single impurities in insulators are now often used for quantum sensors and single photon sources, while nanoscale semiconductor doping features are being constructed for electrical contacts in quantum technology devices, implying that new methods for sensitive, non‐destructive imaging of single‐ or few‐atom structures are needed. X‐ray fluorescence (XRF) can provide nanoscale imaging with chemical specificity, and features comprising as few as 100 000 atoms have been detected without any need for specialized or destructive sample preparation. Presently, the ultimate limits of sensitivity of XRF are unknown – here, gallium dopants in silicon are investigated using a high brilliance, synchrotron source collimated to a small spot. It is demonstrated that with a single‐pixel integration time of 1 s, the sensitivity is sufficient to identify a single isolated feature of only 3000 Ga impurities (a mass of just 350 zg). With increased integration (25 s), 650 impurities can be detected. The results are quantified using a calibration sample consisting of precisely controlled numbers of implanted atoms in nanometer‐sized structures. The results show that such features can now be mapped quantitatively when calibration samples are used, and suggest that, in the near future, planned upgrades to XRF facilities might achieve single‐atom sensitivity.

36 MATERIALS SCIENCE↗

Assessment of metadynamic recrystallization in single copper particle impacts by focused ion beam tomography

We study single Cu-on-Cu impacts relevant to cold spray deposition and quantitatively analyze the metadynamic recrystallization (mDRX) that takes place after the impact by virtue of lingering impact adiabatic heat. Unlike prior studies, the current full 3D tomographic analysis of the mDRX volume shows that mDRX is extremely common in such impacts, although it is often missed when examining 2D sections. We also report an unexpected trend: there is a “sour spot” for mDRX at velocities about 20–40 % above the velocity for particle adhesion. This non-monotonic trend is contrary to the expectations based on increasing adiabatic heating with velocity. With a schematic model, we show that the trend can be explained on the basis of heat transfer: cooling of the heat-affected region is limited by transport through the bonded regions at the particle-substrate interface. Thus, bonding has a prominent role in the heat dissipation process and the best bonded particles most rapidly bulk quench, avoiding mDRX. Here, the developed semi-empirical model aligns with the experimental findings and may help inform microstructural evolution during cold spray and post-spray processing.

FIB-SEM tomography↗

Solid-phase isotope harvesting of 88 Zr from a radioactive ion beam facility

During routine operation of the Facility for Rare Isotope Beams (FRIB), radionuclides will accumulate in both the aqueous beam dump and along the beamline in the process of beam purification. These byproduct radionuclides, many of which are far from stability, can be collected and purified for use in other scientific applications in a process called isotope harvesting. In this work, the viability of 88 Zr harvesting from solid components was investigated at the National Superconducting Cyclotron Laboratory. A secondary 88 Zr beam was stopped in a series of collectors comprised of Al, Cu, W, and Au foils. Here, this work details irradiation of the collector foils and the subsequent radiochemical processing to isolate the deposited 88 Zr (and its daughter 88 Y) from them. Total average recovery from the Al, Cu, and Au collector foils was (91.3 ± 8.9) % for 88 Zr and (95.0 ± 5.8) % for 88 Y, respectively, which is over three times higher recovery than in a previous aqueous-phase harvesting experiment. The utility of solid-phase isotope harvesting to access elements such as Zr that readily hydrolyze in near-neutral pH aqueous conditions has been demonstrated for application to harvesting from solid components at FRIB.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Single-shot measurements of pulse-front tilt in intense ps laser pulses and its effect on accelerated electron and ion beam characteristics (invited)

Here we report recent single-shot spatiotemporal measurements of laser pulses, including pulse-front tilt (PFT) and spatial chirp, taken at the Compact Multipulse Terawatt laser at the Jupiter Laser Facility in Livermore, CA. STRIPED FISH, a device that measures the complete 3D electric field of fs to ps laser pulses on a single shot, was adapted to near infrared for these measurements. We present the design of the instrument used for these experiments, the on-shot measurements of systematic high-order PFT, and shot-to-shot variations in the measurements of spatiotemporal couplings. Finally, we simulate the effect of PFT in target normal sheath acceleration experiments. These simulations showed that pulse front tilt can steer hot electrons, shape the distribution of the accelerating sheath field, and increase the variability of cutoff energy in the resulting proton spectra. While these effects may be detrimental to experimental accuracy if the pulse front tilt is left unmeasured, hot electron steering shows promise for precision manipulation of the particle source for a range of applications, including irradiation of secondary targets for opacity measurements, radiography, or neutron generation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of beam ion driven Alfvén eigenmode stability induced by Tungsten contamination in EAST

Alfvén eigenmodes (AE) activity is observed in the EAST high β N and low B T discharge 93910, operation scenario dedicated to explore the ITER baseline scenario. AEs are triggered after the plasma is contaminated by Tungsten that causes an abrupt variation of the thermal plasma and energetic particles (EPs) profiles. The aim of the present study is to analyze the AE stability in the 93910 discharge using the gyro-fluid code FAR3d, identifying the AE stability trends by comparing the plasma before and after the Tungsten contamination. Tungsten contamination causes the destabilization of Toroidal AEs (TAE) and Energetic particle modes (EPMs) in the same frequency range and radial location with respect to the experimental observation and M3D-K/GTAW code results. Next, a set of parametric studies are performed to analyze the effect of the thermal plasma and EP parameters on the AE stability. The analysis indicates a lower EP β threshold for the AEs destabilization if the EP energy increases, an improved AE stability of on-axis NBI configurations due to the stronger continuum damping in the inner plasma region as well as a large enhancement of the EP drive as the thermal ion density increases due to a higher ratio of the EP and Alfven velocities. Consequently, the simulations indicate the increment of the thermal ion density after the Tungsten contamination could be the main cause of the AE/EPM destabilization.

AE↗

Optical Interference for the Guidance of Cryogenic Focused Ion Beam Milling Beyond the Axial Diffraction Limit

Using a tri-coincident cryogenic FIB-SEM-LM system, we identify an interferometric optical response that can be used for targeting lamella production to fluorescently labelled structures with accuracy beyond the diffraction limit. We demonstrate the approach using synthetic samples of fluorescent beads embedded in micron-scale droplets of water. Here, we then apply the approach to capture virions inside host cells. Successful targeting is confirmed by cryogenic electron tomography revealing clusters of virions in intracellular vesicles.

Sica, Anthony V. [SLAC National Accelerator Labora↗