Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Mechanisms of infrared-laser-assisted atomic ionization by attosecond pulses

We propose a mechanism to understand the infrared (IR) laser assisted atomic ionization by attosecond pulses (AP). Atomic structures in an IR laser field are described by Floquet states and atoms can be ionized to a Floquet state by a single AP through different Floquet components. The interference of ionization through different Floquet components results in the oscillation of the ionization yield as a function of the arriving time of the AP. The proposed mechanism explains the recent experimental observations [Johnsson et al., Phys. Rev. Lett. 99, 233001 (2007)]. Furthermore, we find that, for a specified photoelectron energy, the ionization yield always oscillates as a function of the relative phase between the AP and the IR laser for both He and Ar atoms.

74 ATOMIC AND MOLECULAR PHYSICS↗

Pathway of D{sup +} in sequential double ionization of D{sub 2} in an intense laser pulse

Details of the pathway for the dissociative ionization process of the ground electronic state of aligned D{sub 2}{sup +} produced from the first ionization of D{sub 2} in a short ({approx}100 fs) and intense (4.0x10{sup 14} W cm{sup -2}) 480 nm laser pulse are analyzed and visualized. The initial vibrational state of D{sub 2}{sup +} comes from the vertical transformation of the ground state of D{sub 2}. The initial wave packet in the ground electronic state of D{sub 2}{sup +} is outgoing through a dissociation-ionization channel accompanied by a strong coupling between the 1s{sigma}{sub g} and 2p{sigma}{sub u} electronic states. We show explicitly that the transition from the coupling states 1s{sigma}{sub g} and 2p{sigma}{sub u} to the ionization state is not a direct transition, but takes place through other intermediate states having some dissociative energy that results in a relatively wide internuclear distribution of the ionization state.

74 ATOMIC AND MOLECULAR PHYSICS↗

Monte Carlo wave packet approach to dissociative multiple ionization in diatomic molecules

A detailed description of the Monte Carlo wave packet technique applied to dissociative multiple ionization of diatomic molecules in short intense laser pulses is presented. The Monte Carlo wave packet technique relies on the Born-Oppenheimer separation of electronic and nuclear dynamics and provides a consistent theoretical framework for treating simultaneously both ionization and dissociation. By simulating the detection of continuum electrons and collapsing the system onto either the neutral, singly ionized or doubly ionized states in every time step the nuclear dynamics can be solved separately for each molecular charge state. Our model circumvents the solution of a multiparticle Schroedinger equation and makes it possible to extract the kinetic energy release spectrum via the Coulomb explosion channel as well as the physical origin of the different structures in the spectrum. The computational effort is restricted and the model is applicable to any molecular system where electronic Born-Oppenheimer curves, dipole moment functions, and ionization rates as a function of nuclear coordinates can be determined.

74 ATOMIC AND MOLECULAR PHYSICS↗

Single and double ionization in C{sup 6+}+He collisions

Single- and double-ionization processes in C{sup 6+} collisions with the He atom at an incident energy of 100 MeV/amu are studied by direct solution of the time-dependent Schroedinger equation. A time-dependent close-coupling method based on an expansion of a one-electron three-dimensional wave function in the field of He{sup +} is used to calculate single-ionization cross sections. A time-dependent close-coupling method based on an expansion of a two-electron six-dimensional wave function in the field of He{sup 2+} is used to calculate single- and double-ionization cross sections. Electron energy and angle differential cross sections for single ionization are presented for various projectile impact parameters. For relatively large impact parameters, the differential cross sections are in qualitative agreement with ion-atom experiments. Electron energy and angle differential cross sections for double ionization are also presented for a relatively large projectile impact parameter.

74 ATOMIC AND MOLECULAR PHYSICS↗

Alignment-dependent ionization of hydrogen molecules in intense laser fields

Recent experiments showed that the alignment-dependent ionization probabilities of hydrogen molecules vary as a function of laser intensity, and the anisotropy deviates from the prediction of the molecular tunneling ionization model (MO-ADK). To investigate the physical origins of the deviation, we systematically studied the anisotropy of hydrogen molecules in intense laser fields for three wavelengths, 400 nm (multiphoton ionization), 1850 nm (tunneling ionization), and 800 nm (in between), by solving the time-dependent Schroedinger equation with a model potential. The calculated ratio of the ionization probabilities for laser fields parallel and perpendicular to the molecular axis are in reasonable agreement with experiment. Furthermore, by analyzing the molecular wave function and the model potential, we found that the discrepancies between experiment and the MO-ADK prediction originated from the inaccurate coefficients used in the model and that the assumption of isotropy of the effective potential in the tunneling region is invalid.

74 ATOMIC AND MOLECULAR PHYSICS↗

Two-photon double ionization of helium: Evolution of the joint angular distribution with photon energy and two-electron energy sharing

Ab initio calculations of two-photon double ionization of helium with photon energies varying from the nonsequential regime to well above the double-ionization threshold are presented. A systematic study of the joint angular distributions of the two ionized electrons at different energy sharing shows that the role of electron correlations is imprinted in the joint angular distribution. In particular, a rather general pattern is identified in the nonsequential regime that is independent of photon energy, pulse length, and energy sharing between the two electrons. Interestingly, the same distribution pattern is found for the equal-energy-sharing case, even when the photon energy is well above the double-ionization threshold. In the case of an extremely uneven energy sharing, the distribution pattern changes drastically as the photon energy is increased. In particular, when the photon energy is greater than the second-ionization threshold, the dominant emission mode of the two electrons switches gradually from ''back to back'' to ''side by side.'' Finally, the joint angular distribution is found to provide clear evidence of the role of electron correlations in the initial state.

74 ATOMIC AND MOLECULAR PHYSICS↗

Pulse-shape-dependent strong-field ionization viewed with velocity-map imaging

We explore strong field molecular ionization with velocity map imaging of fragment ions produced by dissociation following ionization. Our measurements and ab initio electronic structure calculations allow us to identify various electronic states of the molecular cation populated during ionization, with multiple pathways to individual states highlighted by the pulse shape dependence. In addition, we show that relative populations can be reconstructed from our measurements. The results illustrate how strong field molecular ionization can be complicated by the presence and interaction of multiple cationic states during ionization.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ionization of He atoms during grazing scattering from a metal surface

We present a theoretical analysis of experimental data on ion fractions and polar angular distributions for He atoms and ions produced during grazing scattering of keV neutral He atoms from an atomically clean and flat Al(111) surface. The discussion focuses on the mechanism of Auger ionization for which we have recently presented the first quantitative treatment by an ab initio method [S. Wethekam, Diego Valdes, R. C. Monreal, and H. Winter, Phys. Rev. B 78, 033105 (2008)]. Auger ionization, the inverse process of Auger neutralization, is a dynamical process that converts kinetic energy from the projectile to electronic excitations. We calculate Auger ionization rates and perform molecular-dynamics and Monte Carlo simulations of trajectory and charge state of scattered projectiles. We achieve quantitative agreement with experimental ion fractions and angular distributions. This demonstrates that Auger ionization is an efficient mechanism of ionization. We also discuss the sensitivity of the results on the theoretical input used in the simulations and give an estimate on the contribution of resonant processes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Equation of state for partially ionized carbon and oxygen mixtures at high temperatures

The equation of state (EOS) for partially ionized carbon, oxygen, and carbon-oxygen mixtures at temperatures 3x10{sup 5} K < or approx. T < or approx. 3x10{sup 6} K is calculated over a wide range of densities, using the method of free energy minimization in the framework of the chemical picture of plasmas. The free energy model is an improved extension of our model previously developed for pure carbon [Potekhin, Massacrier, and Chabrier, Phys. Rev. E 72, 046402 (2005)]. The internal partition functions of bound species are calculated by a self-consistent treatment of each ionization stage in the plasma environment taking into account pressure ionization. The long-range Coulomb interactions between ions and screening of the ions by free electrons are included using our previously published analytical model, recently improved, in particular for the case of mixtures. We also propose a simple but accurate method of calculation of the EOS of partially ionized binary mixtures based on detailed ionization balance calculations for pure substances.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Angular Tunneling Ionization Probability of Fixed-in-Space H{sub 2} Molecules in Intense Laser Pulses

We propose a new approach to obtain molecular frame photoelectron angular distributions from molecules ionized by intense laser pulses. With our method we study the angular tunnel ionization probability of H{sub 2} at a wavelength of 800 nm over an intensity range of 2-4.5x10{sup 14} W/cm{sup 2}. We find an anisotropy that is stronger than predicted by any existing model. To explain the observed anisotropy and its strong intensity dependence we develop an analytical model in the framework of the strong-field approximation. It expresses molecular ionization as a product of atomic ionization rate and a Fourier transform of the highest occupied molecular orbital filtered by the strong-field ionization process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Field Ionization of Cold Atoms near the Wall of a Single Carbon Nanotube

We observe the capture and field ionization of individual atoms near the side wall of a single suspended nanotube. Extremely large cross sections for ionization from an atomic beam are observed at modest voltages due to the nanotube's small radius and extended length. The effects of the field strength on both the atomic capture and the ionization process are clearly distinguished in the data, as are prompt and delayed ionizations related to the locations at which they occur. Efficient and sensitive neutral atom detectors can be based on the nanotube capture and wall ionization processes.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Demonstration of Turnstiles as a Chaotic Ionization Mechanism in Rydberg Atoms

We present an experimental and theoretical study of the chaotic ionization of quasi-one-dimensional potassium Rydberg wave packets via a classical phase-space turnstile mechanism. Turnstiles form a general transport mechanism for numerous chaotic systems, and this study explicitly illuminates their relevance to atomic ionization. We create time-dependent Rydberg wave packets, subject them to alternating applied electric-field pulses, and measure the electron survival probability. Ionization depends not only on the initial electron energy, but also on the classical phase-space position of the electron with respect to the turnstile--that part of the electron packet inside the turnstile ionizes after the applied ionization sequence, while that part outside the turnstile does not. The survival data thus encode information on the shape and location of the turnstile, in good agreement with theoretical predictions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microwave remote sensing of ionized air.

We present observations of microwave scattering from ambient room air ionized with a negative ion generator. The frequency dependence of the radar cross section of ionized air was measured from 26.5 to 40 GHz (Ka-band) in a bistatic mode with an Agilent PNA-X series (model N5245A) vector network analyzer. A detailed calibration scheme is provided to minimize the effect of the stray background field and system frequency response on the target reflection. The feasibility of detecting the microwave reflection from ionized air portends many potential applications such as remote sensing of atmospheric ionization and remote detection of radioactive ionization of air.

99 GENERAL AND MISCELLANEOUS↗

Correction factors for A1SL ionization chamber dosimetry in TomoTherapy: Machine-specific, plan-class, and clinical fields

Purpose: Recently, an international working group on nonstandard fields presented a new formalism for ionization chamber reference dosimetry of small and nonstandard fields [Alfonso et al., Med. Phys. 35, 5179-5186 (2008)] which has been adopted by AAPM TG-148. This work presents an experimental determination of the correction factors for reference dosimetry with an Exradin A1SL thimble ionization chamber in a TomoTherapy unit, focusing on: (i) machine-specific reference field, (ii) plan-class-specific reference field, and (iii) two clinical treatments. Methods: Ionization chamber measurements were performed in the TomoTherapy unit for intermediate (machine-specific and plan-class-specific) calibration fields, based on the reference conditions defined by AAPM TG-148, and two clinical treatments (lung and head-and-neck). Alanine reference dosimetry was employed to determine absorbed dose to water at the point of interest for the fields under investigation. The corresponding chamber correction factors were calculated from alanine to ionization chamber measurements ratios. Results: Two different methods of determining the beam quality correction factor k{sub Q,Q{sub 0}} for the A1SL ionization chamber in this TomoTherapy unit, where reference conditions for conventional beam quality determination cannot be met, result in consistent values. The observed values of overall correction factors obtained for intermediate and clinical fields are consistently around 0.98 with a typical expanded relative uncertainty of 2% (k = 2), which when considered make such correction factors compatible with unity. However, all of them are systematically lower than unity, which is shown to be significant when a hypothesis test assuming a t-student distribution is performed (p=1.8x10{sup -2}). Correction factors k{sub Q{sub c{sub l{sub i{sub n,Q{sub p{sub c{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub p}{sub c}{sub s}{sub r}}}}}}}}}} and k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}, which are needed for the computation of field factors for relative dosimetry of clinical beams, have been found to be very close to unity for two clinical treatments. Conclusions: The results indicate that the helical field deliveries in this study (including two clinical fields) do not introduce changes on the ion chamber correction factors for dosimetry. For those two specific clinical cases, ratios of chamber readings accurately represent field output factors. The values observed here for intermediate calibration fields are in agreement with previously published data based on alanine dosimetry but differ from values recently reported obtained via radiochromic dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance parameters of a liquid filled ionization chamber array

Purpose: In this work, the properties of the two-dimensional liquid filled ionization chamber array Octavius 1000SRS (PTW-Freiburg, Germany) for use in clinical photon-beam dosimetry are investigated.Methods: Measurements were carried out at an Elekta Synergy and Siemens Primus accelerator. For measurements of stability, linearity, and saturation effects of the 1000SRS array a Semiflex 31013 ionization chamber (PTW-Freiburg, Germany) was used as a reference. The effective point of measurement was determined by TPR measurements of the array in comparison with a Roos chamber (type 31004, PTW-Freiburg, Germany). The response of the array with varying field size and depth of measurement was evaluated using a Semiflex 31010 ionization chamber as a reference. Output factor measurements were carried out with a Semiflex 31010 ionization chamber, a diode (type 60012, PTW-Freiburg, Germany), and the detector array under investigation. The dose response function for a single detector of the array was determined by measuring 1 cm wide slit-beam dose profiles and comparing them against diode-measured profiles. Theoretical aspects of the low pass properties and of the sampling frequency of the detector array were evaluated. Dose profiles measured with the array and the diode detector were compared, and an intensity modulated radiation therapy (IMRT) field was verified using the Gamma-Index method and the visualization of line dose profiles.Results: The array showed a short and long term stability better than 0.1% and 0.2%, respectively. Fluctuations in linearity were found to be within ±0.2% for the vendor specified dose range. Saturation effects were found to be similar to those reported in other studies for liquid-filled ionization chambers. The detector's relative response varied with field size and depth of measurement, showing a small energy dependence accounting for maximum signal deviations of ±2.6% from the reference condition for the setup used. The σ-values of the Gaussian dose response function for a single detector of the array were found to be (0.72 ± 0.25) mm at 6 MV and (0.74 ± 0.25) mm at 15 MV and the corresponding low pass cutoff frequencies are 0.22 and 0.21 mm{sup −1}, respectively. For the inner 5 × 5 cm{sup 2} region and the outer 11 × 11 cm{sup 2} region of the array the Nyquist theorem is fulfilled for maximum sampling frequencies of 0.2 and 0.1 mm{sup −1}, respectively. An IMRT field verification with a Gamma-Index analysis yielded a passing rate of 95.2% for a 3 mm/3% criterion with a TPS calculation as reference.Conclusions: This study shows the applicability of the Octavius 1000SRS in modern dosimetry. Output factor and dose profile measurements illustrated the applicability of the array in small field and stereotactic dosimetry. The high spatial resolution ensures adequate measurements of dose profiles in regular and intensity modulated photon-beam fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetric characteristics of the novel 2D ionization chamber array OCTAVIUS Detector 1500

Purpose: The dosimetric properties of the OCTAVIUS Detector 1500 (OD1500) ionization chamber array (PTW-Freiburg, Freiburg, Germany) have been investigated. A comparative study was carried out with the OCTAVIUS Detector 729 and OCTAVIUS Detector 1000 SRS arrays. Methods: The OD1500 array is an air vented ionization chamber array with 1405 detectors in a 27 × 27 cm{sup 2} measurement area arranged in a checkerboard pattern with a chamber-to-chamber distance of 10 mm in each row. A sampling step width of 5 mm can be achieved by merging two measurements shifted by 5 mm, thus fulfilling the Nyquist theorem for intensity modulated dose distributions. The stability, linearity, and dose per pulse dependence were investigated using a Semiflex 31013 chamber (PTW-Freiburg, Freiburg, Germany) as a reference detector. The effective depth of measurement was determined by measuring TPR curves with the array and a Roos chamber type 31004 (PTW-Freiburg, Freiburg, Germany). Comparative output factor measurements were performed with the array, the Semiflex 31010 ionization chamber and the Diode 60012 (both PTW-Freiburg, Freiburg, Germany). The energy dependence of the OD1500 was measured by comparing the array’s readings to those of a Semiflex 31010 ionization chamber for varying mean photon energies at the depth of measurement, applying to the Semiflex chamber readings the correction factor k{sub NR} for nonreference conditions. The Gaussian lateral dose response function of a single array detector was determined by searching the convolution kernel suitable to convert the slit beam profiles measured with a Diode 60012 into those measured with the array’s central chamber. An intensity modulated dose distribution measured with the array was verified by comparing a OD1500 measurement to TPS calculations and film measurements. Results: The stability and interchamber sensitivity variation of the OD1500 array were within ±0.2% and ±0.58%, respectively. Dose linearity was within 1% over the range from 5 to 1000 MU. The effective point of measurement of the OD1500 for dose measurements in RW3 phantoms was determined to be (8.7 ± 0.2) mm below its front surface. Output factors showed deviations below 1% for field sizes exceeding 4 × 4 cm{sup 2}. The dose per pulse dependence was smaller than 0.4% for doses per pulse from 0.2 to 1 mGy. The energy dependence of the array did not exceed ±0.9%. The parameter σ of the Gaussian lateral dose response function was determined as σ{sub 6MV} = (2.07 ± 0.02) mm for 6 MV and σ{sub 15MV} = (2.09 ± 0.02) mm for 15 MV. An IMRT verification showed passing rates well above 90% for a local 3 mm/3% criterion. Conclusions: The OD1500 array’s dosimetric properties showed the applicability of the array for clinical dosimetry with the possibility to increase the spatial sampling frequency and the coverage of a dose distribution with the sensitive areas of ionization chambers by merging two measurements.

07 ISOTOPE AND RADIATION SOURCES↗

Technical Note: Experimental determination of the effective point of measurement of two cylindrical ionization chambers in a clinical proton beam

Purpose: IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement of 0.75 times the inner cavity radius (0.75R) for heavy ion beams. Theoretical models by Palmans and by Bhullar and Watchman confirmed this value. However, the experimental results vary from author to author. The purpose of this study is to accurately measure the displacement and explain the past experimental discrepancies. Methods: In this work, we measured the EPOM of cylindrical ionization chambers with high accuracy by comparing the Bragg-peak position obtained with cylindrical ionization chambers (PTW 30013, PTW 31016) to that obtained using a plane-parallel ionization chamber (PTW 34045). Results: The EPOMs of PTW 30013 and 31016 were shifted by 0.92 ± 0.07 R with R = 3.05 mm and 0.90 ± 0.14 R with R = 1.45 mm, respectively, from the reference point toward the source. Conclusions: The EPOMs obtained were greater than the value of 0.75R proposed by the IAEA TRS-398 and the analytical results.

07 ISOTOPE AND RADIATION SOURCES↗

MO-FG-CAMPUS-IeP1-05: New Ionization Chamber Dosimetry of Absorbed Dose to Water in Diagnostic KV X-Ray Beams

Purpose: To develop new ionization chamber dosimetry of absorbed dose to water in diagnostic kV x-ray beams, by using a beam quality conversion factor, kQ, for Co-60 to kV x-ray and an ionization conversion factor for a water-substitute plastic phantom. Methods: kQ was calculated for aluminum half value-layers (Al-HVLs) of 1.5 mm to 8 mm which were generated by kV x-ray beams of 50 to 120 kVp. Twenty-two energy spectra for ten effective energies (Eeff) were calculated by a SpecCalc program. Depth doses in water were calculated at 5 × 5 to 30 × 30 cm{sup 2} fields. Output factors were also obtained from the dose ratio for a 10 × 10 cm{sup 2} field. kQ was obtained for a PTW30013 Former ion chamber. In addition, an ionization conversion factor of the PWDT phantom to water was calculated. All calculations were performed with EGSnrc/cavity code and egs-chamber codes. Results: The x-ray beam energies for 1.5 mm to 8 mm Al-HVLs ranged in Eeff of 25.7 to 54.3 keV. kQ for 1.5 mm to 8 mm Al-HVLs were 0.831 to 0.897, at 1 and 2 cm depths for a 10 × 10 cm2 field. Similarly, output factors for 5 × 5 to 30 × 30 cm{sup 2} fields were 0.937 to 1.033 for 25.7 keV and 0.857 to 1.168 for 54.3 keV. The depth dose in a PWDT phantom decreased up to 5% compared to that in water at depth of ten percent of maximum dose for 1.5 mm Al-HVL. The ionization ratios of water/PWDT phantoms for the PTW30013 chamber were 1.012 to 1.007 for 1.5 mm to 8 mm Al-HVLs at 1 cm depth. Conclusion: It became possible to directly measure the absorbed dose to water with the ionization chamber in diagnostic kV x-ray beams, by using kQ and the PWDT phantom.

07 ISOTOPE AND RADIATION SOURCES↗