Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser absorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Comparison of eye-safe solid state laser DIAL with passive gas filter correlation measurements from aircraft and spacecraft

Differential Absorption Lidar (DIAL) using solid state Ti:sapphire lasers finds current application in the NASA/LASE Project for H2O vapor measurements in the approximately = 0.820 micron region for the lower and mid-troposphere and in potential future applications in planned measurements of the approximately = 0.940 micron region where both strong and weak absorption lines enables measurements throughout the troposphere and lower stratosphere. The challenge exists to perform measurements in the eye-safe greater than 1.5 micron region. A comparison between DIAL and passive Gas Filter Correlation Radiometer (GFCR) measurements is made. The essence of the differences in signal to noise ratio for DIAL and passive GFCR measurements is examined. The state of the art of lasers and optical parametric oscillators (OPO's) is discussed.

Hess, Robert V.↗

Continuous-Wave, Diode-Pumped, Tunable Tm,Ho:YLF Laser

Unique features include high efficiency and tunability at wavelengths near 2.067 micrometers. Continuous-wave, diode-pumped Tm,Ho:YLF laser tuned by tilting Fabry-Perot etalon and/or adjusting temperature of Tm,Ho:YLF crystal. Proposed for use in remote sensing of winds and in remote sensing of CO2 and H2O, of which many strong absorption lines over-lap laser tuning range. Range extended by tuning to wave-length between CO2 and H2O absorption peaks.

Mcguckin, Brendan T.↗

Monitoring atmospheric pollutants with a heterodyne radiometer transmitter-receiver

The presence of selected atmospheric pollutants can be determined by transmitting an infrared beam of proper wavelength through the atmosphere, and detecting the reflections of the transmitted beam with a heterodyne radiometer transmitter-receiver using part of the laser beam as a local oscillator. The particular pollutant and its absorption line strength to be measured are selected by the laser beam wave length. When the round-trip path for the light is known or measured, concentration can be determined. Since pressure (altitude) will affect the shape of the molecular absorption line of a pollutant, tuning the laser through a range of frequencies, which includes a part of the absorption line of the pollutant of interest, yields pollutant altitude data from which the altitude and altitude profile is determined.

Menzies, R. T.↗

A Two Micron Coherent Differential Absorption Lidar Development

A pulsed, 2-micron coherent Differential Absorption Lidar (DIAL)/Integrated Path Differential Absorption (IPDA) transceiver, developed under the Laser Risk Reduction Program (LRRP) at NASA, is integrated into a fully functional lidar instrument. This instrument measures atmospheric CO2 profiles (by DIAL) from a ground platform. It allows the investigators to pursue subsequent in science-driven deployments, and provides a unique tool for Active Sensing of CO2 Emissions over Night, Days, and Seasons (ASCENDS) validation that was strongly advocated in the recent ASCENDS Workshop. Keywords: Differential Absorption Lidar, Near Infrared Laser,

Yu, Jirong↗

Non-invasive optical detection of glucose in cell culture nutrient medium

The objective of the proposed research was to begin the development of a non-invasive optical sensor for measuring glucose concentration in the output medium of cell cultures grown in a unique NASA bioreactor referred to as an integrated rotating-wall vessel (IRWV). The input, a bovine serum based nutrient media, has a known glucose concentration. The cells within the bioreactor digest a portion of the glucose. Thus, the non-invasive optical sensor is needed to monitor the decrease in glucose due to cellular consumption since the critical parameters for sustained cellular productivity are glucose and pH. Previous glucose sensing techniques have used chemical reactions to quantify the glucose concentration. Chemical reactions, however, cannot provide for continuous, real time, non-invasive measurement as is required in this application. Our effort while in the fellowship program was focused on the design, optical setup, and testing of one bench top prototype non-invasive optical sensor using a mid-infrared absorption spectroscopy technique. Glucose has a fundamental vibrational absorption peak in the mid-infrared wavelength range at 9.6 micron. Preliminary absorption data using a CO2 laser were collected at this wavelength for water based glucose solutions at different concentrations and one bovine serum based nutrient medium (GTSF) with added glucose. The results showed near linear absorption responses for the glucose-in-water data with resolutions as high at 108 mg/dl and as low as 10 mg/dl. The nutrient medium had a resolution of 291 mg/dl. The variability of the results was due mainly to thermal and polarization drifts of the laser while the decrease in sensitivity to glucose in the nutrient medium was expected due to the increase in the number of confounders present in the nutrient medium. A multispectral approach needs to be used to compensate for these confounders. The CO2 laser used for these studies was wavelength tunable (9.2 to 10.8 micrometers), however, it was to unstable across wavelengths to test the multispectral approach. From this research, further NASA support was obtained to continue the work throughout the year in which a more stable light source will be used at smaller, near-infrared, wavelengths. It is anticipated that a more compact, non-invasive, optical glucose sensor will be realized which can be used with a bioreactor on future space shuttle missions. It is also anticipated that a multispectral optical sensor may be used to determine the concentration of other molecules needed within the NASA bioreactor, such as fructose and galactose.

Cote, Gerald L.↗

Pattern-Recognition Algorithm for Locking Laser Frequency

A computer program serves as part of a feedback control system that locks the frequency of a laser to one of the spectral peaks of cesium atoms in an optical absorption cell. The system analyzes a saturation absorption spectrum to find a target peak and commands a laser-frequency-control circuit to minimize an error signal representing the difference between the laser frequency and the target peak. The program implements an algorithm consisting of the following steps: Acquire a saturation absorption signal while scanning the laser through the frequency range of interest. Condition the signal by use of convolution filtering. Detect peaks. Match the peaks in the signal to a pattern of known spectral peaks by use of a pattern-recognition algorithm. Add missing peaks. Tune the laser to the desired peak and thereafter lock onto this peak. Finding and locking onto the desired peak is a challenging problem, given that the saturation absorption signal includes noise and other spurious signal components; the problem is further complicated by nonlinearity and shifting of the voltage-to-frequency correspondence. The pattern-recognition algorithm, which is based on Hausdorff distance, is what enables the program to meet these challenges.

Karayan, Vahag↗

An Efficient Single Frequency Ho:YLF Laser for IPDA Lidar Applications

A highly efficient, versatile, single frequency 2-micron pulsed laser can be used in a pulsed Differential Absorption Lidar (DIAL) / Integrated Path Differential Absorption (IPDA) instrument to make precise, high-resolution measurements to investigate sources and sinks of CO2. For a direct detection IPDA lidar, the desired 2 m Ho:YLF laser should generate 30-40 mJ pulses at the repetition rate of 100 to 200 Hz, with short pulse length (<100 ns) and better than 2% wall plug efficiency. A Tm fiber laser in-band pumped Ho:YLF laser has been developed to meet this technical challenge. This Ho:YLF laser is designed in a four mirror ring resonator with bow tie configuration, which helps to obtain high beam quality. It is end-pumped by a 40 W linearly polarized Tm fiber laser at 1.94μm. The resonator length is 1.10 meters with output coupler reflectivity at 45%. The laser crystal size is 3 x 3 x 60 mm (w, h, l) with a doping concentration of 0.5% Holmium. The laser beam and pump beam are mode-matched in the active medium. Thus, the pump and laser beams have the same confocal parameters. Mode-matching is also helpful for operating the laser in a single transverse mode. The laser beam waist is slightly less than 0.5 mm at the center of the laser crystal. Based on quasi-four level modeling, pump absorption and saturation depend on laser intensity. Laser amplification and saturation also depend on the pump intensity in the crystal. The laser is injection seeded to obtain the single frequency required by an IPDA lidar measurement. The seed beam is entered into the resonator through an output coupler. The laser is mounted on a water cooled optical bench for stable and reliable operation. The size of the optical bench is 22.16 x 9.20 x 1.25 inches. It is stiffened so that the laser can be operated in any orientation of the optical bench. This packaged Ho:YLF laser is designed for either mobile trailer or airborne platform operation. The engineering prototype Ho:YLF laser has been fully characterized to demonstrate laser performance. Figure 1 shows the laser output power as a function of pump power at different pulse repetition rates from 100 Hz to 333 Hz. The threshold of the laser is less than 14 W. The slope efficiencies are 28%, 40%, 41% and 43% for pulse repetition rates of 100, 200, 250 and 333 Hz, respectively. Maximum power increases with the pulse repetition rate. Output power of 4.2 W, 6 W, 6.7 W, and 7.7 W is achieved for pulse repetition rates of 100, 200, 250 and 333Hz, respectively. This represents the optical conversion efficiency of 16.7%, 22.4%, 23.7%, and 26.5% at these various pulse repletion rates. It is the most efficient and compact Ho:YLF laser demonstrated in the high pulse energy (>20mJ) and moderate pulse repetition rate (100's Hz) operation range. As shown in Figure 1, the maximum pulse energy at 100 Hz is 42 mJ. This is limited due to optical damage. The laser stability is characterized and found to be very stable. A relative pulse energy standard deviation of 2% was measured. The beam quality of the Ho:YLF was measured by a Spiricon infrared laser beam camera. Figure 2 shows the beam profile image of the laser. Both the X-profile of the beam (horizontal direction) and the Y-profile of the beam (vertical direction) are well fitted by a Gaussian profile. The qualitative beam quality measurement shows excellent beam quality in both axis. The M-square value for the laser beam is measured at 1.06 and 1.09 for the x and y axis respectively.-

Yu, J.↗

Online Rapid Analysis of Laser Heterodyne Radiometer (LHR) Data Using the Planetary Spectrum Generator (PSG)

One of the biggest challenges in developing scientific instruments is not just the build and testing of an instrument, but the method for processing the data and producing a consistent, well characterized data product that can be confidently used by the public and scientific community. Raw data products are frequently an array of numbers that are a read-out of voltages. The challenge is to convert these arrays into meaningful information as well as remove noise and interferences. Because this can be a tedious and time-consuming, the goal is to automate the process so that data ca be processed rapidly and be available in real-time for event monitoring. Here we present a rapid analysis method for Laser Heterodyne Radiometer (LHR) data that can be used to analyze data taken from a range of LHR observation modes (column, limb, etc.). This online tool uses the versatile Planetary Spectrum Generator (PSG) and allows LHR users to quickly analyze their own data using a NASA Goddard Space Flight Center (GSFC) monitored capability to ensure quality and reproducibility in the data products. Background: Development of a miniaturized LHR (mini-LHR) as a ground instrument for measuring carbon dioxide (CO 2 ) and methane (CH 4 ) in the atmospheric column started in 2009 with the commercial availability of distributive feedback lasers (DFB) in wavelengths that could measure absorption of gases in the near-IR. As new DFB lasers, detectors and hardware emerged at different wavelengths, additional gases were added to the capability. The mini-LHR was adapted into an occultation-viewing CubeSat with Lawrence Livermore National Laboratory (LLNL) for observing CO 2 , CH 4 , and H 2 O in the limb and was launched in 2019. Other versions of the LHR technology have been designed for observation of water vapor in the lunar exosphere as well as observations of trace gases in planetary atmospheres and plumes from icy moons. The PSG is an online tool developed at GSFC that can be used for synthesizing Earth and planetary spectra (atmospheres and surfaces) over a broad range of wavelengths (0.1 μm to 100 mm) for any observatory, orbiter or lander. Spectra are simulated by combining several state-of-the-art radiative transfer models, spectroscopic databases, planetary databases, as well as modern-era retrospective analysis for research and applications, version 2 (MERRA-2) data set which provides meteorological inputs such as modeled surface pressure for calculating dry-air columns.

Emily Wilson↗

Rare-isotope and kinetic studies of Pt/SnO2 catalysts

Closed-cycle pulsed CO2 laser operation requires the use of an efficient CO-O2 recombination catalyst for these dissociation products which otherwise would degrade the laser operation. The catalyst must not only operate at low temperatures but also must operate efficiently for long periods. In the case of the Laser Atmospheric Wind Sounder (LAWS) laser, an operational lifetime of 3 years is required. Additionally, in order to minimize atmospheric absorption and enhance aerosol scatter of laser radiation, the LAWS system will operate at 9.1 micrometers with an oxygen-18 isotope CO2 lasing medium. Consequently, the catalyst must not only operate at low temperatures but must also preserve the isotopic integrity of the rare-isotope composition in the recombination mode. Several years ago an investigation of commercially available and newly synthesized recombination catalysts for use in closed-cycle pulsed common and rare-isotope CO2 lasers was implemented at the NASA Langley Research Center. Since that time, mechanistic efforts utilizing both common and rare oxygen isotopes have been implemented and continue. Rare-isotope studies utilizing commercially available platinum-tin oxide catalyst have demonstrated that the catalyst contributes oxygen-16 to the product carbon dioxide thus rendering it unusable for rare-isotope applications. A technique has been developed for modification of the surface of the common-isotope catalyst to render it usable. Results of kinetic and isotope label studies using plug flow, recycle plug flow, and closed internal recycle plug flow reactor configuration modes are discussed.

Upchurch, Billy T.↗

Measurements of kinetic processes in a self-sustained discharge XeF laser

Measurements are presented for processes occurring in XeF self-sustained discharges including fluorescence, gain, and absorption at different wavelengths as a function of F2, Xe, and He partial pressures. Time-correlated oscillograms are given for the laser discharge current, metastable XeF small-signal gain at 351.1 nm, transient absorptions at 333.6 and 363.8 nm, metastable-XeF B-state sidelight emission at about 350 nm, metastable-F emission at 634.8 nm, and metastable-F emission at 731.1 nm. It is found that He atoms are necessary for the production of metastable-XeF in its lower vibrational levels and that radiative processes and He quenching are the primary mechanisms for metastable-XeF decay. For small-signal gains of as low as about 8%/cm, the transient absorption at the laser wavelength may be as large as about 1-2%/cm.

Gower, M. C.↗

Remote probing of the atmosphere using a CO2 DIAL system

An overview of our laser remote sensing effort is presented. Using both fundamental and frequency-doubled CO2 laser radiation in a differential absorption LIDAR (DIAL) system, background concentrations of CO, NO, and C2H4 in the atmosphere as well as increases due to localized emission sources have been measured. These species have been detected using the backscattered laser radiation from topographic targets at ranges to 2.7 km with a sensitivity of plus or minus 10 ppb. In addition, using a dual-laser DIAL system, the effect of induced correlation of the LIDAR returns due to atmospheric turbulence has been investigated. These results have been used to help quantify the accuracy of the DIAL measurements and are shown to be consistent with theory.

Killinger, D. K.↗

Supersonic-nitrogen flow-field measurements with the resonant Doppler velocimeter

The application of the resonant Doppler velocimeter (RDV) for obtaining the mean velocity, temperature, and pressure measurements and flow-field visualization in a supersonic free nitrogen jet is reported. This method utilizes laser-induced fluorescence to determine the spectral absorption of an atomic or molecular species seeded into the flow. A narrow linewidth tunable laser is directed into the flow and the total fluorescence from any point is obtained as the laser is tuned. The velocity of the flow is obtained from the Doppler shifted absorption frequency, and the temperature and pressure of the gas are determined from line broadening measurements. Results are presented for the use of this technique to determine the velocity, temperature, and pressure of the flow of sodium atoms seeded into a supersonic nitrogen jet. It is concluded that the visible signal is sufficiently intense for spatially resolved flow visualization purposes.

Cheng, S.↗

Optimization of A 2-Micron Laser Frequency Stabilization System for a Double-Pulse CO2 Differential Absorption Lidar

A carbon dioxide (CO2) Differential Absorption Lidar (DIAL) for accurate CO2 concentration measurement requires a frequency locking system to achieve high frequency locking precision and stability. We describe the frequency locking system utilizing Frequency Modulation (FM), Phase Sensitive Detection (PSD), and Proportional Integration Derivative (PID) feedback servo loop, and report the optimization of the sensitivity of the system for the feed back loop based on the characteristics of a variable path-length CO2 gas cell. The CO2 gas cell is characterized with HITRAN database (2004). The method can be applied for any other frequency locking systems referring to gas absorption line.

Chen, Songsheng↗

Airborne tunable diode laser system for trace gas measurements

Sachse et al. (1976) have reported the development of an airborne tunable diode laser (TDL) system, named the Differential Absorption CO Monitor (DACOM). The absorption path was 10 m long and located in the free airstream along the fuselage of a C-54 aircraft. The present investigation is concerned with a modification of the DACOM instrument. Differences between the new instrument and the original one are related to a replacement of the external absorption path with a White cell. The instrument has the capability to suppress TDL excess noise. The laser refrigerator has been redesigned to permit an alternative method of cooling the TDL when electric power is not available.

Sachse, G. W.↗

Alexandrite laser transmitter development for airborne water vapor DIAL measurements

In the DIAL technique, the water vapor concentration profile is determined by analyzing the lidar backscatter signals for laser wavelengths tuned 'on' and 'off' a water vapor absorption line. Desired characteristics of the on-line transmitted laser beam include: pulse energy greater than or equal to 100 mJ, high-resolution tuning capability (uncertainty less than 0.25 pm), good spectral stability (jitter less than 0.5 pm about the mean), and high spectral purity (greater than 99 percent). The off-line laser is generally detuned less than 100 pm away from the water vapor line. Its spectral requirements are much less stringent. In our past research, we developed and demonstrated the airborne DIAL technique for water vapor measurements in the 720-nm spectral region using a system based on an alexandrite laser as the transmitter for the on-line wavelength and a Nd:YAG laser-pumped dye laser for the off-line wavelength. This off-line laser has been replaced by a second alexandrite laser. Diode lasers are used to injection seed both lasers for frequency and linewidth control. This eliminates the need for the two intracavity etalons utilized in our previous alexandrite laser and thereby greatly reduces the risk of optical damage. Consequently, the transmitted pulse energy can be substantially increased, resulting in greater measurement range, higher data density, and increased measurement precision. In this paper, we describe the diode injection seed source, the two alexandrite lasers, and the device used to line lock the on-line seed source to the water vapor absorption feature.

Chyba, Thomas H.↗

Interchange for Joint Research Entitled: Miniature Laser Spectrometer for Stable Isotope Measurements

As a first step in successfully measuring carbon isotopes optically we have previously demonstrated the measurement of C-13/C-12 to a precision of 0.1% using a tunable diode laser and CO2 spectral lines in the 2300/cm spectral region. This precision of 0.1% (1 per mil) for carbon isotopes is a value sufficiently precise to provide important isotopic data of interest to astrobiologists. The precision presently attainable in gases is sufficient to permit our instrument to be used in the measurement of isotopic ratios of interest to astrobiologists as well as geologists and planetary scientists. A small stable isotope laser spectrometer with a 10 cm path gas cell was designed and constructed. The cell was integrated with a liquid nitrogen cooled tunable diode laser and indium antimonide detector for evaluation. Using the small gas cell, preliminary measurements of 13C/12C in CO2 were made employing single-beam sequential acquisitions of the required spectral data. The results indicate an accuracy of 0.1% which is sufficiently high to make meaningful measurements of martian samples. In addition, improvements in the spectrometer gas handling system have been made to markedly reduce C-13/C-12 isotopic fractionation during sample gas cell loading which we expect will lead to further improvements in precision and accuracy. An important part of making isotopic ratio measurements in solid samples using diode lasers is the conversion of the elements of interest to molecules that have absorption spectra in the mid-ir spectral range accessible by tunable diode lasers. In this project we have investigated the necessary sample preparation procedures to extract carbon, an element of astrobiological importance, from model soil compounds and to convert it to CO2, a molecule with appropriate optical absorption characteristics for reliable laser spectrometer isotopic ratio measurements of 13C/12C. We have considered calcium carbonate as a model for a component of the martian regolith, and we have formulated a simple heating protocol for extracting carbon in the form of CO2.

Becker, J. F.↗

Spectral line absorption measurement using optical cavities.

A simple technique using a conventional gas laser with spherical mirrors having identical radii of curvature in the nonoscillating regime for spectral line absorption measurements is described and applications for laser work are suggested. The theory of the measurement carried out in the geometrical optical approach for Doppler-broadened lines was checked experimentally and conditions are specified for which measurement inaccuracies of the order of 1% for the peak value of the line absorption coefficient can be obtained. Since the device provides a fine adjustment of the cavity losses, formation of the diffraction modes could be observed in the preoscillating regime of the optical cavity.

Blanaru, D. L.↗

New acousto-ultrasonic techniques applied to aerospace materials

The use of an NdYAG pulsed laser for generating ultrasonic waves for NDE in resin matrix composites was investigated. A study was conducted of the use of the 1.064 micron wavelength NdYAG pulsed laser with the neat, unreinforced resin as well as graphite fiber/polymer composite specimens. In the case of the neat resins it was found that, at normal incidence, about 25 percent of the laser pulse energy was reflected at the incident surface. An attenuation coefficient for the polyimide resin, PMR-15 was determined to be approximately 5.8 np/cm. It was found in energy balance studies that graphite fiber/polymer specimens attenuate the laser beam more than do neat resins. The increase absorption is in the graphite fibers. The occurrence of laser induced surface damage was also studied. For the polymer neat resin, damage appears as pit formation over a small fraction of the pulse impact area and discoloration over a larger part of the area. A damage threshold was inferred from observed damage as a function of pulse energy. The 600 F cured PMR-15 and PMR-11 exhibit about the same amount of damage for a given laser pulse energy. The damage threshold is between 0.06 and 0.07 J/sq cm.

Kautz, Harold E.↗