Search NASA⌕ Search

SEARCH · Search NASA

Results for “materials testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Crystal growth of sulfide materials from alkali polysulfide liquids

The fluids experiment system was designed for low temperature solution growth, nominally aqueous solution growth. The alkali polysulfides, compositions in the systems Na2S-S and K2S-S form liquids in the temperature range of 190 C to 400 C. These can be used as solvents for other important classes of materials such as transition metal and other sulfides which are not soluble in aqueous media. Among these materials are luminescent and electroluminescent crystals whose physical properties are sensitive functions of crystal perfection and which could, therefore, serve as test materials for perfection improvement under microgravity conditions.

White, W. B.↗

Ablation of carbonaceous materials in a hydrogen-helium arc-jet flow

The stagnation-point ablation rates of a graphite, a carbon-carbon composite, and four carbon-phenolic materials are measured in an arc-jet wind tunnel with a 50 percent hydrogen-50 percent helium mixture as the test gas. Flow environments are determined through measurements of static and impact pressures, heat-transfer rates to a calorimeter, and radiation spectra, and through numerical calculation of the flow through the wind tunnel, spectra, and heat-transfer rates. The environments so determined are: impact pressure approximately equal to 3 atm, Mach number approximately equal to 2.1, convective heat-transfer rate approximately equal to 14 kW/sq cm, and radiative heat-transfer rate approximately equal to 7 kW/sq cm in the absence of ablation. Ablation rates are determined from the measured rates of mass loss and recession of the ablation specimens. Compared with the predicted ablation rates obtained by running RASLE and CMA codes, the measured rates are higher by about 15 percent for all tested materials.

Park, C.↗

Mass spectrometers and atomic oxygen

The likely role of atmospheric atomic oxygen in the recession of spacecraft surfaces and in the shuttle glow has revived interest in the accurate measurement of atomic oxygen densities in the upper atmosphere. The Air Force Geophysics Laboratory is supplying a quadrupole mass spectrometer for a materials interactions flight experiment being planned by the Johnson Space Center. The mass spectrometer will measure the flux of oxygen on test materials and will also identify the products of surface reactions. The instrument will be calibrated at a new facility for producing high energy beams of atomic oxygen at the Los Alamos National Laboratory. The plans for these calibration experiments are summarized.

Hunton, D. E.↗

Plastic Recycling Experiments in Materials Education

The objective of this project was to introduce a series of plastic recycling experiments to students in materials-related courses such as materials science, material technology and materials testing. With the plastic recycling experiments, students not only can learn the fundamentals of plastic processing and properties as in conventional materials courses, but also can be exposed to the issue of materials life cycle and the impact on society and environment.

Liu, Ping↗

Selective Laser Melting Inconel 718 Restart Study

Selective Laser Melting (SLM) machines can occasionally shut down (such as in the event of a power failure), which requires the SLM build to be restarted. It has been observed that machine restarts can produce visible "restart lines" in the part, and, in at least one instance, a test specimen containing a restart line exhibited poor mechanical properties. The goal of this study is to evaluate the effect of different machine restart factors on the mechanical properties of the produced SLM material. Test specimens were produced by varying time to restart, the number of re-sinters, and whether or not the build required re-levelling. These are build variables that are typically controlled by the machine operator. Test results indicate that re-leveling and using three re-sinters produces acceptable material. Statistical analysis indicates that re-leveling and re-sintering have strong effects on the resulting material properties. Additionally, the visibility of a restart line loosely correlates with material properties such that obvious restart lines tended to indicate worse material properties.

Tilson, William G.↗

Advanced Materials Laboratory User Test Planning Guide

Test process, milestones and inputs are unknowns to first-time users of the Advanced Materials Laboratory. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

Advanced Materials Laboratory↗

Conductivity effects in high-voltage spacecraft insulating materials

Laboratory measurements were performed to assess the influence of various external parameters on the conductivity properties of several typical and potential spacecraft insulating materials in a simulated space environment. The materials tested include Kapton, Teflon, quartz, and polyvinylidene fluoride. The parameters measured comprise sample thickness, temperature, applied voltage, illumination intensity and wavelength, and electron beam energy and current density. All tests were conducted in a vacuum chamber at a pressure of about one millionth Torr both with conventional optically-transparent gold front-surface electrodes and with the front surfaces of the test samples exposed directly to an electron beam. The data presented illustrate some of the complexities in electrical characteristics exhibited by the materials as a result of interactions with various conditions of their environment.

Adamo, R. C.↗

A study of subsurface crack initiation produced by rolling contact fatigue

Results of subsurface crack initiation studies produced by pure rolling contact fatigue in 7075-T6 aluminum alloy are presented in this article. Microstructural changes and subsequent crack initiation below the contacting surface in cylindrical test specimens subjected to repeated rolling contact are illustrated. The rolling conditions are simulated in a three-dimensional elastic-plastic finite element model in order to estimate the plastic strains and residual stresses in the test material. The numerically estimated distribution of plastic strains in the model correlate well with the extent of microstructural changes observed in the test specimen. Results also indicate that a combination of plastic strains and low values of residual stresses is conducive to subsurface crack initiation and growth.

Kumar, Arun M.↗

Applying Additive Manufacturing to a New Liquid Oxygen Turbopump Design

A liquid oxygen turbopump has been designed at Marshall Space Flight Center as part of the in-house, Advanced Manufacturing Demonstrator Engine (AMDE) project. Additive manufacturing, specifically direct metal laser sintering (DMLS) of Inconel 718, is used for 77% of the parts by mass. These parts include the impeller, turbine components, and housings. The near-net shape DMLS parts have been delivered and final machining is underway. Fabrication of the traditionally manufactured hardware is also proceeding. Testing in liquid oxygen is planned for Q2 of FY2017. This topic explores the design of the turbopump along with fabrication and material testing of the DMLS hardware.

O'Neal, Derek↗

Variance Decomposition of MEDLI2 Reconstructed Heating Using Neural Networks

The Mars Entry, Descent, and Landing Instrumentation (MEDLI2) sensor suite collected data during entry of the Mars 2020 Perseverance rover into Mars’ atmosphere. This suite included a network of MEDLI2 Instrumented Sensor Plugs (MISPs). Each MISP was comprised of a cylinder made of Thermal Protection System (TPS) material with 1-3 embedded thermocouples (TCs), and it was flush mounted into the heatshield or backshell. Data from these in-depth TCs were used to reconstruct the aeroheating environment of the vehicle throughout entry. Surface heating was posed as an inverse problem, with the goal of estimating the surface heating by minimizing an objective function of the difference between MISP temperature measurements during flight and the temperature predictions derived from the Fully Implicit Ablation and Thermal response (FIAT) program. Given an aerothermal environment, FIAT calculates the material response and provides in-depth temperatures throughout the TPS material. To achieve the reverse, an internal tool called FIAT_Opt runs through multiple different environments until the output temperature at the TC depth closely matches the flight data. 95% confidence intervals on the reconstructed surface heating were obtained using Monte Carlo analysis, in which uncertainties in the thermocouple depth and the TPS material properties (e.g., density, thermal conductivity, heat capacity, emissivity) based on flight-lot material testing were included. A variance decomposition method using Sobol indices was employed to assess the sensitivity of the reconstructed peak heating to the TC placement and material property uncertainties. Variance decomposition was found to require tens of thousands of FIAT_Opt runs in order for the Sobol indices to converge. With a single FIAT_Opt run taking on the order of 40 minutes, the required number of computations would take months to complete, even if using multiple CPUs. To mitigate this problem, three machine learning models (ridge regression with cross-validation, random forest regression, and a deep neural network) were trained and tested using the 2000 Monte Carlo runs that were already completed. A subset of 1600 runs were used to train the model (i.e., training set), while the remaining 400 runs were used as the test set. The predictions from the deep neural network (DNN) on the test set showed nearly perfect agreement to the actual values computed with FIAT_Opt (R2 > 0.99). Using the DNN as a surrogate model, the variance decomposition using 50,000 runs was completed within minutes. The resulting Sobol indices showed that the reconstructed peak surface heating was most sensitive to the uncertainties in the thermal conductivity (ST = 0.37) and heat capacity (ST = 0.26). This method can be leveraged to provide requirements for material property measurements needed to improve the accuracy of surface heating prediction and ultimately lead to the reduction of design margins in the future. This presentation will include background on the MEDLI2 suite; the method used for inverse heating estimation; the way that material property uncertainties were accounted for using Monte Carlo analysis; a brief background on variance decomposition; the motivation for using machine learning in this context; how a neural network was trained on the data to enable variance decomposition in a fraction of the time; and the variance decomposition results for one of the MISPs.

Hannah Alpert↗

Program definition and preliminary results of a long-term evaluation program of advanced composites for supersonic cruise aircraft applications

Advanced composites will play a key role in the development of the technology required for the design and fabrication of future supersonic vehicles. A program is in progress to determine the time-temperature-stress capabilities of several high-temperature composite materials. Tests included in this study are thermal aging, ambient aging, fatigue, creep, fracture, tensile, and real-time flight-simulation exposure. The program has two parts. The first includes all the material-property determinations and aging and simulation exposures up through 10,000 h. The second continues these tests up to 50,000 cumulative h. The program is currently in the midst of the 10,000-h phase. Some of the results obtained to date and the status of the various tests are discussed.

Kerr, J. R.↗

Combined Experimental and Modeling Study of the Interactions of Acid Gas with Common Spacecraft Surfaces for Fire Safety Applications

A fire in a spacecraft poses detrimental consequences and risks mission success in addition to crew safety. This is compounded during long-duration missions when the crew has limited options to recover from a fire. A common spacecraft fire concern is the smoldering of wire insulation, typically made from Polyvinyl chloride (PVC) or Polytetrafluoroethylene (PTFE). This creates acid gases such as Hydrogen Chloride (HCl), Hydrogen Fluoride (HF) and Hydrogen Cyanide (HCN). These poisonous gases are hazardous to the crew. They also interact with common surfaces within the spacecraft more than dominant combustion products such as CO2 and H2O. This makes them more difficult to track for potential fire detection techniques, or for postfire clean-up. It is imperative to be able to understand and predict the fate of these poisonous species in a microgravity environment in order to design a safe vehicle. HCl interacts with a number of materials inside a spacecraft. Primary among these materials is aluminum, which is abundantly used due to its strong and light weight nature. Aluminum has a natural oxide layer that protects it from corrosion but is typically treated to enhance this oxide layer. Among these treatments is a chromate conversion coating (CCC), which provides a thin enough protective oxide layer to still conduct electricity, and a traditional anodized material that has a thicker oxide layer that does not conduct electricity. Nomex is another common material found inside a spacecraft. It is a flame-resistant woven polymer that is related to nylon. This commercially available material is used for cargo storage bags and as a fire barrier. Physics-based models were developed to predict the uptake of HCl by these materials. The ultimate objective of these models is to predict the fate of HCl within the spacecraft so that sensors can be placed in meaningful locations in future missions based on the model predictions. To support these modeling efforts, experiments were performed in a cast acrylic test cell that measured the difference between the inlet and outlet concentration of HCl after inserting a sample rod of the test material. Different uptake capacities were realized for each type of sample tested. A computational fluid dynamics model (CFD) model of the reactor was then constructed that used a one-step global reaction rate with calibratable reaction (or kinetic) constants. These constants were calibrated to match the HCl uptake on the CCC aluminum samples, and the same kinetic constants were then tested for the stock and anodized aluminum samples. Model predictions matched the experimental data for the stock aluminum, and to a much lesser extent, the anodized aluminum. The model was additionally validated at different flow rates, sample surface areas, and inlet concentrations, and showed good agreement for all stock and CCC samples. The model did not accurately predict the HCl uptake in the anodized samples compared to the other two types of aluminum. Adjusting the kinetic constants and transport properties did little to improve the prediction. X-Ray Photoelectron Spectroscopy (XPS) was used to determine that the oxide layer thickness of anodized aluminum is approximately 5,000 nm, compared to 250 nm for CCC and 50 nm for stock. XPS also revealed presence of chlorine further down in the aluminum oxide layer in anodized samples than CCC and stock samples after the samples were saturated with HCl, indicating that accounting for diffusion of HCl into the oxide layer is important for accurate prediction of HCl uptake onto anodized aluminum. Consequently, a multi-scale model was developed and tested. First, a single pore inside the anodized aluminum oxide layer was modeled and is referred to as the pore-scale model. In this model, HCl diffused through the pore and reacted with the aluminum oxide pore wall to create aluminum chloride. The sample was then saturated when the mass transfer resistance through the growing aluminum chloride layer became too large for the HCl to reach the aluminum oxide wall and continue the reaction. This pore-scale model was coupled to the reactor-scale model using a concentration-dependent diffusion coefficient, resulting in much more accurate predictions (approximately half the sum square error of the aforementioned reactor-scale model that produced good agreement for stock and CCC) for a variety of operating conditions. The amount of water vapor or relative humidity (RH) in the flow during a reactor experiment was determined to influence HCl uptake. Experiments were performed to understand the interaction of gaseous HCl with aluminum surfaces in the presence of water vapor. The results show that increasing levels of RH increased the capacity of aluminum to adsorb HCl but decreased the capacity of Nomex to uptake HCl. A series of tests were performed on individual aluminum samples after they had been saturated with a fixed concentration of HCl in dry air conditions with the goal of determining how their HCl uptake capacity changes after various treatments with water relative to the original saturation tests. HCl-saturated aluminum samples subjected to a second dry air flow at the same HCl concentration as the original test had an uptake of 23.5% of the original sample with no treatment in between. Saturated aluminum samples subjected to an air flow with a RH of 90% in between tests had an uptake of 35.6% of the original. Saturated aluminum samples submerged in distilled water for 12 hours in between tests had an uptake of 82.2% of the original sample. Previously saturated aluminum tested with HCl and a 50% RH air flow resulted in similar uptake characteristics in multiple repeated tests. The experiments show the profound effect water vapor has on HCl uptake onto aluminum surfaces. In the samples subjected to water vapor or liquid water, capillary condensation and capillary diffusion alters the transport of HCl significantly. A model was proposed that developed a relationship between RH and the coefficient of HCl diffusion in aluminum chloride. This produced an “S-shaped” curve with diffusion coefficient as a function of RH, with 45% RH represented as the point where the diffusion coefficient is halfway between no water saturation and 100% water saturation in the aluminum chloride product layer. No difference in uptake characteristics for the experiment or model were realized between 50% and 62% RH. The results from the large-scale microgravity experiment, Saffire, are discussed as they pertain to the fate of HCl throughout a spacecraft. HCl was released, both as a standalone event, and in concurrence with the burning of a structured cloth. These events only produced a small response in the far field HCl sensor, while a PMMA burn that did not produce HCl had a significantly greater response. A ground-based large-scale facility was constructed to flow acid gas at the scale and configuration realized in the Saffire experiments. A CFD model of this duct was constructed to test kinetic parameters developed in this work at a larger scale and different geometric configuration and to predict the results of the large-scale facility. The models developed in this work were used to interpret the results of the microgravity tests and lead the discussion on what further experiments and models are needed in order to predict the fate of acid gas in a spacecraft environment. To summarize, the major contributions of this work are as follows: the capacity to uptake HCl, with and without the presence of water vapor, was measured for a variety of real spacecraft surfaces. Several different models (single reactor-scale, multiscale, spacecraft-scale) were developed and with the aid of modeling, the rate of uptake for those surfaces was also predicted and validated. The kinetic parameters determined from the small-scale reactor experiments and models were used to predict large-scale and microgravity tests. Conclusions from this research will be used in the design of spacecraft vehicles and large-scale microgravity fire safety experiments. The models built by this work will aid designers in sensor placement and could be used to predict acid gas transport from fires in partial gravity, as would be seen in Lunar and Martian habitats.

fire safety↗

Laboratory simulation of Low Earth Orbit (LEO) atomic oxygen effects

A pulsed fast oxygen atom source has been used extensively over the last 7 years to investigate the effects of ambient oxygen atoms impacting materials placed in low Earth orbit. In this period, we irradiated well over 2000 material samples with 8 km/s oxygen atoms generated in our source. Typical irradiance level is 3 x 10(exp 20) O atoms/sq cm although some materials have been irradiated to fluence levels as high as 6 x 10(exp 21) O atoms/sq cm. The operating principles and characteristics of our source are reviewed along with diagnostic and handling procedures appropriate to material testing. Representative data is presented on the velocity dependence of oxygen atom erosion rates (the PSI source provides oxygen atoms tunable over the velocity range of 5 to 12 km/s) as well as the dependence on material temperature. Specific examples of non-linear oxidative effects related to surface contamination and test duration are also be provided.

Caledonia, George E.↗

Stable isotope analysis of molecular oxygen from silicates and oxides using CO2 laser extraction

A laser-excited system for determination of the oxygen isotope composition of small quantities of silicate and oxide minerals was constructed and tested at JSC. This device is the first reported to use a commercially available helium cryostat to transfer and purify oxygen gas quantitatively within the system. The system uses oxygen gas instead of the conventional CO2 for mass spectrometer analyses. This modification of technique permits determination of all three stable oxygen isotopes, an essential requirement for oxygen isotope analysis of meteoritic material. Tests of the system included analysis of standard silicate materials NBS 28 and UWMG2 garnet, six SNC meteorites, and inclusions and chondrules from the Allende meteorite. Calibration with terrestrial standards was excellent. Meteorite values are close to published values and show no evidence of terrestrial oxygen contamination. The one limitation observed is that, in some runs on fine-grained SNC matrix material, sample results were affected by other samples in the sample holder within the reaction chamber. This reemphasizes the need for special precautions in dealing with fine-grained, reactive samples. Performance of the JSC instrument compares favorably with that of any other instrument currently producing published oxygen isotope data.

Perry, Eugene↗

The effect of changes in the USF/NASA toxicity screening test method on data from some cellular polymers

Rankings of relative toxicity can be markedly affected by changes in test variables. Revision of the USF/NASA toxicity screening test procedure to eliminate the connecting tube and supporting floor and incorporate a 1.0 g sample weight, 200 C starting temperature, and 800 C upper limit temperature for pyrolysis, reversed the rankings of flexible polyurethane and polychloroprene foams, not only in relation to each other, but also in relation to cotton and red oak. Much of the change is attributed to reduction of the distance between the sample and the test animals, and reduction of the sample weight charged. Elimination of the connecting tube increased the relative toxicity of the polyurethane foams. The materials tested were flexible polyurethane foam, without and with fire retardant; rigid polyurethane foam with fire retardant; flexible polychloroprene foam; cotton, Douglas fir, red oak, hemlock, hardboard, particle board, polystyrene, and polymethyl methacrylate.

Hilado, C. J.↗

Advanced development of double-injection, deep-impurity semiconductor switches

Deep-impurity, double-injection devices, commonly refered to as (DI) squared devices, represent a class of semiconductor switches possessing a very high degree of tolerance to electron and neutron irradiation and to elevated temperature operation. These properties have caused them to be considered as attractive candidates for space power applications. The design, fabrication, and testing of several varieties of (DI) squared devices intended for power switching are described. All of these designs were based upon gold-doped silicon material. Test results, along with results of computer simulations of device operation, other calculations based upon the assumed mode of operation of (DI) squared devices, and empirical information regarding power semiconductor device operation and limitations, have led to the conculsion that these devices are not well suited to high-power applications. When operated in power circuitry configurations, they exhibit high-power losses in both the off-state and on-state modes. These losses are caused by phenomena inherent to the physics and material of the devices and cannot be much reduced by device design optimizations. The (DI) squared technology may, however, find application in low-power functions such as sensing, logic, and memory, when tolerance to radiation and temperature are desirable (especially is device performance is improved by incorporation of deep-level impurities other than gold.

Hanes, M. H.↗

Eddy Current System for Material Inspection and Flaw Visualization

Eddy current methods have been successfully used in a variety of non-destructive evaluation applications including detection of cracks, measurements of material thickness, determining metal thinning due to corrosion, measurements of coating thickness, determining electrical conductivity, identification of materials, and detection of corrosion in heat exchanger tubes. This paper describes the development of an eddy current prototype that combines positional and eddy-current data to produce a C-scan of tested material. The preliminary system consists of an eddy current probe, a position tracking mechanism, and basic data visualization capability. Initial test results of the prototype are presented in this paper.

Bachnak, R.↗