Search NASA⌕ Search

SEARCH · Search NASA

Results for “microscopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Electron microscope phase enhancement

A microfabricated electron phase shift element is used for modifying the phase characteristics of an electron beam passing though its center aperture, while not affecting the more divergent portion of an incident beam to selectively provide a ninety-degree phase shift to the unscattered beam in the back focal plan of the objective lens, in order to realize Zernike-type, in-focus phase contrast in an electron microscope. One application of the element is to increase the contrast of an electron microscope for viewing weakly scattering samples while in focus. Typical weakly scattering samples include biological samples such as macromolecules, or perhaps cells. Preliminary experimental images demonstrate that these devices do apply a ninety degree phase shift as expected. Electrostatic calculations have been used to determine that fringing fields in the region of the scattered electron beams will cause a negligible phase shift as long as the ratio of electrode length to the transverse feature-size aperture is about 5:1. Calculations are underway to determine the feasibility of aspect smaller aspect ratios of about 3:1 and about 2:1.

47 OTHER INSTRUMENTATION↗

Scientists View Battery Under Microscope

PNNL researchers use a special microscope setup that shows the inside of a battery as it charges and discharges. This battery-watching microscope is located at EMSL, DOE's Environmental Molecular Sciences Laboratory that resides at PNNL. Researchers the world over can visit EMSL and use special instruments like this, many of which are the only one of their kind available to scientists.

25 ENERGY STORAGE↗

Polarized pulsed front-end beam source for electron microscope

A method and an electron source are provided for generating polarized electrons for an electron microscope. The electron source includes a photoemissive cathode and a low-power drive laser. The geometry of the photoemissive cathode uses a generally planar emission surface, which is imaged to approximately 1/100 its initial size via electrostatic focusing elements. The virtual emitter, or image spot, then is used as an electron source by a conventional microscope column.

Lewellen, John W.↗

High content screening workflows for microscope imaging

Disclosed herein are systems methods for high content screening for microscope imaging. In some embodiments, the system comprises: a microscope; and a processor configured to implement: a slide loader module; a reference imager module; a slide imager module; a region of interest (ROI) finder module; a compare imager module; a calibrator module; and an image stitcher module.

42 ENGINEERING↗

Electron Microscopic Examination of an Irradiated TRISO Coated Particle of AGR-2 Experiment: AGR2-222-RS019

The transmission electron microscopic (TEM) examination of an irradiated tristructural isotropic (TRISO) coated particle from advanced gas reactor (AGR) 2 fuel Compact 2-2-2 is presented in this report. Compact 2-2-2 refers to the compact in Capsule 2 at Level 2 of Stack 2. The examination on AGR2 222 RS019 is focused on the interface between the silicon carbide (SiC) to inner pyrolytic carbon (IPyC) layer, central part of SiC, and the interface between SiC and outer pyrolytic carbon layer. The SiC grain boundary distribution and associated fission product precipitates were characterized by scanning transmission electron microscopy (STEM) energy dispersive spectroscopy (EDS), and precession electron diffraction (PED) in the transmission electron microscope. Two separate locations on SiC layer were selected for on the basis of the intact of the buffer layer in the irradiated TRISO particle. The key observation in this particle is that the compositional nature of grain boundary precipitates is more complex near IPyC/SiC layer where Pd, Pd-Ag, Pd-U containing precipitates can be observed. However, the compositions of precipitate towards outer most region of SiC mainly contain Pd. Ag has been observed in the IPyC/SiC layer in one of the two locations. Comparison of the results to previously irradiated and analyzed, Variant 3, safety tested AGR-1 TRISO particles (AGR1-433-001 and AGR1 222-RS004) showed the grain boundary distributions have some noticeable differences. The differences in coincident site lattice grain boundary and misorientation angles are possibly inherent to the fabrication process. Neutron irradiation induced void distribution has been found to be nonuniform. A high concentration of smaller voids is found at stacking faults compared to those in the SiC matrix. Larger void sizes are observed in the SiC location that is near to the broken buffer layer. This void size variation with integrity of buffer layer can potentially affect the fission product retention. However, the average void size continuously decreases along the radius of SiC in both locations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integrated transmission electron microscope

An integrated transmission electron microscope comprising multiple electron sources for tuned beams of ultrafast, scanning probe, and parallel illumination in varied beam energies can be alternated within sub-microseconds onto a sample with dynamic ‘transient state’ processes to acquire atomic-scale structural/chemical data with site specificity. The various electron sources and condenser optics enable high-resolution imaging, high-temporal resolution imaging, and chemical imaging, using fast-switching magnets to direct the different electron beams onto a single maneuverable objective pole piece where the sample resides. Such multimodal in situ characterization tools housed in a single microscope have the potential to revolutionize materials science.

Jungjohann, Katherine L.↗

Ion and electron beam nanofabrication of the which-way double-slit experiment in a transmission electron microscope

We have realized a which-way experiment closely resembling the original Feynman's proposal exploiting focused ion beam milling to prepare two nanoslits and electron beam induced deposition to grow, selectively over one of them, electron transparent layers of low atomic number amorphous material to realize a which-way detector for high energy electrons. By carrying out the experiment in an electron microscope equipped with an energy filter, we show that the inelastic scattering of electron transmitted through amorphous layers of different thicknesses provides the control of the dissipative interaction process responsible for the localization phenomena which cancels out the interference effects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Scanning Electron Microscope As An Accelerator For The Undergraduate Advanced Physics Laboratory

Few universities or colleges have an accelerator for use with advanced physics laboratories, but many of these institutions have a scanning electron microscope (SEM) on site, often in the biology department. As an accelerator for the undergraduate, advanced physics laboratory, the SEM is an excellent substitute for an ion accelerator. Although there are no nuclear physics experiments that can be performed with a typical 30 kV SEM, there is an opportunity for experimental work on accelerator physics, atomic physics, electron-solid interactions, and the basics of modern e-beam lithography.

99 GENERAL AND MISCELLANEOUS↗

Mechanisms Underlying a Quantum Superposition Microscope Based on THz-Driven Coherent Oscillations in a Two-Level Molecular Sensor

Here we report pump-probe measurements of a hydrogen molecule (H 2 ) in the tunnel junction of a scanning tunneling microscope (STM) coupled to ultrashort terahertz (THz) pulses. The coherent oscillation of the THz induced DC tunneling current at a frequency of ~0.5 THz fingerprints the absorption by H 2 as a two-level system (TLS). Two components of the oscillatory signal are observed and point to both photon and field aspects of the THz pulses. A few loosely bound states with similar energies for the upper state of the TLS are evidenced by the coherent revival of oscillatory signal. Furthermore, the comparison of spectroscopic features of H 2 with different tips provides an understanding of the TLS for H 2 .

36 MATERIALS SCIENCE↗

Quantifying and visualizing the microscopic degrees of freedom of grain boundaries in the Wigner–Seitz cell of the displacement-shift-complete lattice

Here we introduce a grain boundary (GB) translation vector, t ws , to describe and quantify the domain of the microscopic degrees of freedom of GBs. It has long been recognized that for fixed macroscopic degrees of freedom of a GB there exists a large multiplicity of states characterized by different relative grain translations. More recently another degree of freedom, [n], the number of GB atoms, has emerged and is now recognized as an equally important component of GB structural multiplicity. In this work, we show that all GB microstates can be uniquely characterized by their value of t ws , which is located within the Wigner–Seitz (WS) cell of the Displacement-Shift-Complete lattice (DSCL) of the GB. The GB translation vector captures information about both the translation state and the number of GB atoms. We show that the density of GB microstates inside the WS cell of the DSCL is not uniform and can form clusters that correspond to different GB phases. Further, the vectors connecting the centers of the clusters correspond to the Burgers vectors of GB phase junctions, which can be predicted without building the junctions. Using t ws , we quantify GB excess shear and argue that it is defined up to a DSCL vector, which has implications for thermodynamic equilibrium conditions. Additionally, this work generalizes the definition of the number of GB atoms [n] to asymmetric boundaries.

36 MATERIALS SCIENCE↗

Measurement of the unstained biological sample by a novel scanning electron generation X-ray microscope based on SEM

We introduced a novel X-ray microscope system based on scanning electron microscopy using thin film, which enables the measurement of unstained biological samples without damage. An unstained yeast sample was adsorbed under a titanium (Ti)-coated silicon nitride (Si{sub 3}N{sub 4}) film 90 nm thick. The X-ray signal from the film was detected by an X-ray photodiode (PD) placed below the sample. With an electron beam at 2.6 kV acceleration and 6.75 nA current, the yeast image is obtained using the X-ray PD. The image is created by soft X-rays from the Ti layer. The Ti layer is effective in generating the characteristic 2.7-nm wavelength X-rays by the irradiation of electrons. Furthermore, we investigated the electron trajectory and the generation of the characteristic X-rays within the Ti-coated Si{sub 3}N{sub 4} film by Monte Carlo simulation. Our system can be easily utilized to observe various unstained biological samples of cells, bacteria, and viruses.

60 APPLIED LIFE SCIENCES↗

Electron microscopic evidence for the myosin head lever arm mechanism in hydrated myosin filaments using the gas environmental chamber

Research highlights: {yields} We succeeded in recording structural changes of hydrated myosin cross-bridges. {yields} We succeeded in position-marking the cross-bridges with site-directed antibodies. {yields} We recorded cross-bridge movement at different regions in individual cross-bridge. {yields} The movement was smallest at the cross-bridge-subfragment two boundary. {yields} The results provide evidence for the cross-bridge lever arm mechanism. -- Abstract: Muscle contraction results from an attachment-detachment cycle between the myosin heads extending from myosin filaments and the sites on actin filaments. The myosin head first attaches to actin together with the products of ATP hydrolysis, performs a power stroke associated with release of hydrolysis products, and detaches from actin upon binding with new ATP. The detached myosin head then hydrolyses ATP, and performs a recovery stroke to restore its initial position. The strokes have been suggested to result from rotation of the lever arm domain around the converter domain, while the catalytic domain remains rigid. To ascertain the validity of the lever arm hypothesis in muscle, we recorded ATP-induced movement at different regions within individual myosin heads in hydrated myosin filaments, using the gas environmental chamber attached to the electron microscope. The myosin head were position-marked with gold particles using three different site-directed antibodies. The amplitude of ATP-induced movement at the actin binding site in the catalytic domain was similar to that at the boundary between the catalytic and converter domains, but was definitely larger than that at the regulatory light chain in the lever arm domain. These results are consistent with the myosin head lever arm mechanism in muscle contraction if some assumptions are made.

60 APPLIED LIFE SCIENCES↗

Pore-scale simulation of gas flow in microscopic permeable media with complex geometries

Lattice Boltzmann method (LBM) is an efficient tool to perform direct numerical simulation of gas flow in micro-size pores. Despite great advances in LBM and its use in describing gas flow in micro-size channels in slip and transitional flow regimes, exploring formulations that are able to capture flow behavior in domains with complex boundary geometries remains a challenging task. As a result, the impact of complexities in pore structures on gas flow may not be fully explored using LBM. In this study, we propose to use the combined bounce-back and Maxwellian diffusive reflection scheme to capture the slip velocity with a new set of slip coefficients. Optimal values of slip coefficients are determined using a gradient based method, where the results from the linearized Boltzmann equation is used as the reference solution. The proposed formulation is further validated against predictions from molecular dynamics simulation in the presence of complex geometries by introducing obstacles of different shapes in straight channels. LBM with the proposed boundary treatment is then used to investigate gas flow in a synthetic microscopic permeable medium. Here, results indicate that gas exhibits different flow configurations as Knudsen number varies, and apparent gas permeability appears to have up to a second-order dependency on the reciprocal mean pressure in slip and transitional flow regimes.

03 NATURAL GAS↗

Identification of Fragile Microscopic Structures during Mineral Transformations in Wet Supercritical CO2

In this study we examine the nature of highly fragile reaction products that form in low water content super critical carbon dioxide (scCO2) using a combination of scanning electron microscopy/focus ion beam (SEM/FIB), confocal Raman spectroscopy, helium ion microscopy (HeIM), and transmission electron microscopy (TEM). HeIM images show these precipitates to be fragile rosettes that can readily decompose even under slight heating from an electron beam. Using the TEM revealed details on the interfacial structure between the newly formed surface precipitates and the underlying initial solid phases. The detailed microscopic analysis revealed that the growth of the precipitates either followed a tip growth mechanism with precipitates forming directly on the forsterite surface if the initial solid was non-porous (natural forsterite) or growth from the surface of the precipitates where fluid was conducted through the porous (nanoforsterite) agglomerates to the growth center. The mechanism of formation of the hydrated/hydroxylated magnesium carbonate compound (HHMC) phases offers insight into the possible mechanisms of carbonate mineral formation from scCO2 solutions which has recently received a great deal of attention as the result of the potential for CO2 to act as an atmospheric greenhouse gas and impact overall global warming. The techniques used here to examine these fragile structures an also be used to examine a wide range of fragile material surfaces. SEM and FIB technologies have now been brought together in a single instrument, which represents a powerful combination for the studies in biological, geological and materials science.

carbon↗

Imaging Valley Excitons in a 2D Semiconductor with Scanning Tunneling Microscope-Induced Luminescence

Valley excitons dominate the optoelectronic response of transition-metal dichalcogenides and are drastically affected by structural and environmental inhomogeneities localized in these materials. Critical to understanding and controlling these nanoscale excitonic changes is the ability to correlate the imaging of excitonic states with crystalline structures on the atomic scale. Here, in this study, we apply scanning tunneling microscope-induced luminescence microscopy to image valley excitons in a semiconducting transition-metal dichalcogenide monolayer decoupled by a 10 nanometer-thick hexagonal-boron-nitride flake incorporated in a lateral homojunction on an Au electrode surface. This design enables the observation of chiral excitonic emission arising from neutral and charged valley excitons of the monolayer semiconductor at ambipolar voltages with a quantum efficiency up to similar to ~10 -5 photon/electron. The measured light helicity demonstrates considerable circular polarization dependent on the sample voltage, reaching as much as 40%. The real-space luminescence imaging maps$-$at subnanometer resolution$-$of the valley excitons reveal striking spatial variations associated with localized inhomogeneities, including surface impurities and possibly nanoscale dielectric and/or potential disorders in the monolayer. Our study introduces a promising format for 2D materials to explore and tailor their optoelectronic processes at the atomic scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combined Atomic Force Microscope-Based Topographical Imaging and Nanometer Scale Resolved Proximal Probe Thermal Desorption/Electrospray Ionization-Mass Spectrometry

Nanometer scale proximal probe thermal desorption/electrospray ionization mass spectrometry (TD/ESI-MS) was demonstrated for molecular surface sampling of caffeine from a thin film using a 30 nm diameter nano-thermal analysis (nano-TA) probe tip in an atomic force microscope (AFM) coupled via a vapor transfer line and ESI interface to a MS detection platform. Using a probe temperature of 350 C and a spot sampling time of 30 s, conical desorption craters 250 nm in diameter and 100 nm deep were created as shown through subsequent topographical imaging of the surface within the same system. Automated sampling of a 5 x 2 array of spots, with 2 m spacing between spots, and real time selective detection of the desorbed caffeine using tandem mass spectrometry was also demonstrated. Estimated from the crater volume (~2x106 nm3), only about 10 amol (2 fg) of caffeine was liberated from each thermal desorption crater in the thin film. These results illustrate a relatively simple experimental setup and means to acquire in automated fashion sub-micrometer scale spatial sampling resolution and mass spectral detection of materials amenable to TD. The ability to achieve MS-based chemical imaging with 250 nm scale spatial resolution with this system is anticipated.

atomic force microscope↗

Imaging Single Atoms Using Secondary Electrons with an Aberration-Corrected Electron Microscope

Aberration correction has embarked on a new frontier in electron microscopy by overcoming the limitations of conventional round lenses, providing sub-angstrom-sized probes. However, improvement of spatial resolution using aberration correction so far has been limited to the use of transmitted electrons both in scanning and stationary mode, with an improvement of 20-40%. In contrast, advances in the spatial resolution of scanning electron microscopes (SEMs), which are by far the most widely used instrument for surface imaging at the micrometre-nanometre scale, have been stagnant, despite several recent efforts. Here, we report a new SEM, with aberration correction, able to image single atoms by detecting electrons emerging from its surface as a result of interaction with the small probe. The spatial resolution achieved represents a fourfold improvement over the best-reported resolution in any SEM. Furthermore, we can simultaneously probe the sample through its entire thickness with transmitted electrons. This ability is significant because it permits the selective visualization of bulk atoms and surface ones, beyond a traditional two-dimensional projection in transmission electron microscopy. It has the potential to revolutionize the field of microscopy and imaging, thereby opening the door to a wide range of applications, especially when combined with simultaneous nanoprobe spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗