Analytical characterization of laser induced plasmas towards uranium isotopic analysis in gaseous uranium hexafluoride

To perform direct enrichment assay on gaseous uranium hexafluoride (UF 6 ) with laser induced breakdown spectroscopy (LIBS), the dominant spectral-line features, evolution of the signal and background of the U II 424.437 nm line, and its Stark width and shift, were studied as a function of UF 6 gas pressure and pulse energy of a nanosecond Nd:YAG laser. In this work, vapor pressure of UF 6 was found to be the most important parameter for LIBS analysis of gaseous UF 6 . Spectral congestion with numerous U lines of high excitation potential was observed and signal-to-background ratio (SBR) was low for measurements with 80 Torr UF 6 . Only when both UF 6 vapor pressure and laser pulse energy were low, for example, less than 20 Torr pressure and 30 mJ pulse energy, the resultant LIBS spectra from gaseous UF 6 resembled those obtained from solid U samples. The experimental data also suggest that U and F atoms recombine back to UF 6 after the laser pulse. The U emission was found to decay fast with a persistent background signal, degrading SBR with delay time. Systematic positive biases were found for UF 6 enrichment assays performed with the 235 U– 238 U line pair at 424.412–424.437 nm, which was confirmed to be caused by self-absorption. Even with optimization of experimental parameters and incorporation of a self-absorption term into the spectral-fitting algorithm, to reduce and compensate for self-absorption, self-absorption is still a main factor limiting accurate UF 6 enrichment assay. The use of another spectral window which contains no resonance lines is a prospective solution for the self-absorption issue.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A comb-sampling method for enhanced mass analysis in linear electrostatic ion traps

In this paper an algorithm for extracting spectral information from signals containing a series of narrow periodic impulses is presented. Such signals can typically be acquired by pickup detectors from the image-charge of ion bunches oscillating in a linear electrostatic ion trap, where frequency analysis provides a scheme for high-resolution mass spectrometry. To provide an improved technique for such frequency analysis, we introduce the CHIMERA algorithm (Comb-sampling for High-resolution IMpulse-train frequency ExtRAaction). This algorithm utilizes a comb function to generate frequency coefficients, rather than using sinusoids via a Fourier transform, since the comb provides a superior match to the data. This new technique is developed theoretically, applied to synthetic data, and then used to perform high resolution mass spectrometry on real data from an ion trap. If the ions are generated at a localized point in time and space, and the data is simultaneously acquired with multiple pickup rings, the method is shown to be a significant improvement on Fourier analysis. The mass spectra generated typically have an order of magnitude higher resolution compared with that obtained from fundamental Fourier frequencies, and are absent of large contributions from harmonic frequency components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characteristics of a cylindrical collector mirror for laser-produced xenon plasma soft X-rays and improvement of mirror lifetime by buffer gas

The focusing characteristics of a ruthenium-coated cylindrical mirror were investigated on the basis of its ability to collect and focus broadband 5-17-nm soft X-rays emitted from a laser-produced plasma. Based on the plasmas spectral intensity distribution and the reflectivity function of the mirror, we defined the optimum position of the integrated cylindrical mirror at which the X-ray energy flux transported and focused through the mirror was maximum. A minimum spot diameter of 22 mm at a distance of approximately 200 mm from a soft X-ray source was confirmed. The maximum intensity of the collected soft X-rays was 1.3 mJ/cm{sup 2} at the center of the irradiation zone. Thus, the irradiation intensity was improved by approximately 27 times when compared to that of 47 {mu}J/cm{sup 2} without the mirror. The debris sputtering rate on the reflection surface of the mirror can be reduced to 1/110 by argon gas at 11 Pa, while the attenuation rate of the soft X-rays due to absorption by the buffer gas can be suppressed to less than 10% at the focal point. The focusing property of the mirror is expected to be maintained for 3000 h or longer without significant degradation for a 100 W/320 pps laser shot if the ruthenium layer is thicker than 10 {mu}m. These results suggest that a stand-alone broadband soft X-ray processing system can be realized by using laser-produced plasma soft X-rays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-06: Development of a Formalism for Practical Dose Measurements in Brachytherapy in the German Standard DIN 6803

Purpose: In the steep dose gradients in the vicinity of a radiation source and due to the properties of the changing photon spectra, dose measurements in Brachytherapy usually have large uncertainties. Working group DIN 6803-3 is presently discussing recommendations for practical brachytherapy dosimetry incorporating recent theoretical developments in the description of brachytherapy radiation fields as well as new detectors and phantom materials. The goal is to prepare methods and instruments to verify dose calculation algorithms and for clinical dose verification with reduced uncertainties. Methods: After analysis of the distance dependent spectral changes of the radiation field surrounding brachytherapy sources, the energy dependent response of typical brachytherapy detectors was examined with Monte Carlo simulations. A dosimetric formalism was developed allowing the correction of their energy dependence as function of source distance for a Co-60 calibrated detector. Water equivalent phantom materials were examined with Monte Carlo calculations for their influence on brachytherapy photon spectra and for their water equivalence in terms of generating equivalent distributions of photon spectra and absorbed dose to water. Results: The energy dependence of a detector in the vicinity of a brachytherapy source can be described by defining an energy correction factor kQ for brachytherapy in the same manner as in existing dosimetry protocols which incorporates volume averaging and radiation field distortion by the detector. Solid phantom materials were identified which allow precise positioning of a detector together with small correctable deviations from absorbed dose to water. Recommendations for the selection of detectors and phantom materials are being developed for different measurements in brachytherapy. Conclusion: The introduction of kQ for brachytherapy sources may allow more systematic and comparable dose measurements. In principle, the corrections can be verified or even determined by measurement in a water phantom and comparison with dose distributions calculated using the TG43 dosimetry formalism. Project is supported by DIN Deutsches Institut fuer Normung.

60 APPLIED LIFE SCIENCES↗

Radiation Sensitivity of Natural Organic Matter: Clay Mineral Association Effects in the Callovo-Oxfordian Argillite

Clay-rich low-organic carbon formations (e.g., Callovo-Oxfordian argillite in France and Opalinus Clay in Switzerland) are considered as host rocks for radioactive waste disposal. The clay-organic carbon has a strong impact on the chemical stability of the clays. For this reason, the nature of the clay-organic carbon, the release of hydrophilic organic compounds, namely, humic (HA) and fulvic acids (FA) and the radiation sensitivity of the undisturbed host rock organics was investigated. The clay sample originates from Oxfordian argillite (447 m depth, borehole EST 104). HA and FA were extracted following the standard International Humic Substance Society (IHSS) isolation procedure. Synchrotron based (C-, K-, Ca-, O- and Fe-edge XANES) scanning transmission X-ray microscopy (STXM) and FT-IR microspectroscopy was used to identify under high spatial resolution the distribution of clay-organic matter with different functionality using principal component and cluster analysis. The results show that in this old (Jurassic) geological formation, small parts of the organic inventory (1-5%) keeps the structure/functionality and can be mobilized as hydrophilic humic substance type material (HA and FA). Target spectra analysis shows best correlation for isolated humic acids with organics found in smectite-rich regions, whereas the extractable FA has better spectral similarities with the illite mixed layer minerals (MLM) regions. After radiation of 1.7 GGy under helium atmosphere the same rock sample area was investigated for radiation damage. Radiation damage in the smectite and illite-MLM associated organic matter is comparably low with 20-30% total oxygen mass loss and 13-18% total carbon mass loss. A critical dose dc of 2.5 GGy and a optical density after infinite radiation (OD?) of 54% was calculated under room temperature conditions. C(1s) XANES show a clear increase in Cdouble bond; length as m-dashC bonds especially in the illite-MLM associated organics. This results suggests a combination of the formation of Cdouble bond; length as m-dashC bond due to crosslinking via polymerization and mass loss due to bond breaking (scissioning) in the main chain or in side groups of the organic macromolecules upon irradiation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

HTTR 3 D Cross Section Generation with Serpent and MAMMOTH

The High Temperature Test Reactor (HTTR) is a graphite moderated thermal reactor with a nominal power output of 30 MWth. The purpose of this work is to prepare a set of neutron cross sections for use in the transient analyses of three Loss of Forced Cooling (LOFC) events planned for this reactor. The cross sections are generated with the Serpent 2 3 D Monte Carlo code to include the axial heterogeneity and the strong axial coupling of this core. The approach yields good agreement of results when compared to previously used 2 D lattice models, which require a fine spatial discretization and, surprisingly, comes at a higher computational cost. In addition, the temperature distribution must be considered to obtain reasonable cross sections and the axial leakage component dominates the spectral effects in the core. Consequently, a temperature model as a function of the fuel and moderator temperatures is adopted, and the core is depleted to 390 effective full-power days (EFPDs). A full tabulation of cross sections is prepared at this burnup point for a variety of fuel and moderator temperatures. Next, the multiphysics reactor application MAMMOTH is used to evaluate the quality of these cross sections using a diffusion solver. As expected, the homogenization error in the cross sections is significant and the Super Homogenization (SPH) correction from MAMMOTH is necessary to preserve key reaction rates. The SPH corrected MAMMOTH results are in excellent agreement with the Serpent results and reproduce both the reference power profile and temperature coefficients at each tabulation point. This fact confirms the accuracy of the SPH corrected cross sections and demonstrates the maturity of using Serpent 2 and MAMMOTH for 3 D cross section generation, even for reactors as complex as the HTTR. Finally, the authors recommend that the cross sections should be parametrized with the local burnup and that a full core burnup calculation with coupled thermal fluids would provide a better estimate of the initial condition for any subsequent transient analysis. Unfortunately, this was not within the scope of this work, and direct analysis with these tabulations should be considered as a first order approximation, at best.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Source geometric considerations for OMEGA Dante measurements

The Dante is a 15 channel filtered diode array which is installed on the OMEGA laser facility at the Laboratory for Laser Energetics, University of Rochester. The system yields the spectrally and temporally resolved radiation flux from 50 eV to 10 keV from various targets (i.e., Hohlraum, gas pipes, etc.). The absolute flux is determined from the radiometric calibration of the x-ray diodes, filters, and mirrors and an unfold algorithm applied to the recorded voltages from each channel. The unfold algorithm assumes an emitting source that is spatially uniform and has a constant area as a function of photon energy. The emitting x-ray source is usually considered to be the laser entrance hole (LEH) of a given diameter for Hohlraum type targets or the effective wall area of high conversion efficiency K-shell type targets. This assumption can be problematic for several reasons. High intensity regions or 'hot spots' in the x-ray are observed where the drive laser beams strike the target. The 'hot spots' create non-uniform emission seen by the Dante. Additionally, thinned walled (50 {mu}m) low-Z targets (C{sub 22}H{sub 10}N{sub 2}O{sub 5}) have an energy dependent source size since the target's walls will be fully opaque for low energies (E < 2-3 keV) yet fully transmissive at higher energies. Determining accurate yields can be challenging for these types of targets. Discussion and some analysis will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of ethylenediaminetetraacetic acid on the long-term oxidation state distribution of plutonium

Here, spectrophotometry was used to study the effect of EDTA on plutonium oxidation state distribution as a function of time, pH, and ligand-to-metal ratio (L/M) under anoxic conditions. Novel Pu(V)-EDTA absorption bands were identified at 571, 993, 1105, and 1150 nm with molar absorption coefficients of 15 ± 1, 6 ± 1, 10 ± 1, and 10 ± 1 cm –1 M –1 , respectively. Pu(V)-EDTA spectral changes occurred at L/M < 1, indicating only Pu V O 2 (EDTA) 3- formed with logK = 3.6 ± 0.3. Time-resolved experiments showed EDTA drastically increased the Pu(V/VI) reduction rate, which we propose is driven by amine lone-pair electron donation and the oxidative decarboxylation of EDTA. Oxidation of Pu(III)-EDTA to Pu(IV)-EDTA occurred on a slower time scale (110–237 days) than previously reported (<15 min) and is hypothesized to be radiolysis driven. Pu(V/VI)-EDTA and Pu(III)-EDTA both approached Pu(IV)-EDTA stabilization over time, yet Pu(V/VI)-EDTA solubility data was ≥ 1.0 log 10 units higher than predicted by Pu(IV)-EDTA solubility models, indicating that current thermodynamic models are incomplete. Ultimately, the data show EDTA preferentially stabilizes Pu(IV) over time regardless of initial oxidation state, but Pu(V)-EDTA can persist under environmentally-relevant conditions, emphasizing the need to continue investigating redox reactions, speciation, and behavior of these complexes to support the transuranic waste disposal and surface remediation/containment efforts.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analysis, testing, and operation of the MAGI thermal control system

The Aerospace Corporation has completed the development of the Mineral and Gas Identifier (MAGI) sensor - an airborne multi-spectral infrared instrument that is designed to discriminate surface composition and to detect gas emissions from the environment. Sensor performance was demonstrated in a series of flights aboard a Twin Otter aircraft in December 2011 as a stepping stone to a future satellite sensor design. To meet sensor performance requirements the thermal control system was designed to operate the HgCdTe focal plane array (FPA) at 50 K with a 1.79 W heat rejection load to a 44.7 K sink and the optical assembly at 100 K with a 7.5 W heat load to a 82.3 K sink. Two commercial off-theshelf (COTS) Sunpower Stirling cryocoolers were used to meet the instrument’s cooling requirements. A thermal model constructed in Thermal Desktop was used to run parametric studies that guided the mechanical design and sized the two cryocoolers. This paper discusses the development, validation, and operation of the MAGI thermal control system. Detailed energy balances and temperature predictions are presented for various test cases to demonstrate the utility and accuracy of the thermal model. Model inputs included measured values of heat lift as a function of input power and cold tip temperature for the two cryocoolers. These measurements were also used to make predictions of the cool-down behavior from ambient conditions. Advanced heater software was developed to meet unique requirements for both sensor cool-down rate and stability at the set point temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of NDE for Key Indicators of Aging Cables in Nuclear Power Plants – Interim Status

Degradation of the cable jacket, electrical insulation, and other cable components of installed cables within nuclear power plants (NPPs) is known to occur as a function of age, temperature, radiation, and other environmental factors. System tests verify cable function under normal loads; however, the concern is over cable performance under exceptional loads associated with design-basis events (DBEs). The cable’s ability to perform safely over the initial 40 year planned and licensed life has generally been demonstrated and there have been very few age-related cable failures. With greater than 1000 km of power, control, instrumentation, and other cables typically found in an NPP, replacing all the cables would be a severe cost burden. Justification for life extension to 60 and 80 years requires a cable aging management program to justify cable performance under normal operation as well as accident conditions. Currently the gold standard for determining cable insulation degradation is the elongation-at-break (EAB). This, however, is an ex-situ measurement and requires removal of a sample for laboratory investigation. A reliable nondestructive examination (NDE) in-situ approach is desirable to objectively determine the suitability of the cable for service. A variety of tests are available to assess various aspects of electrical and mechanical cable performance, but none of these tests are suitable for all cable configurations nor does any single test confirm all features of interest. Nevertheless, the complete collection of test possibilities offers a powerful range of tools to assure the integrity of critical cables. Licensees and regulators have settled on a practical program to justify continued operation based on condition monitoring of a lead sample set of cables where test data is tracked in a database and the required test data are continually adjusted based on plant and fleet-wide experience. As part of the Light Water Reactor Sustainability program sponsored by the U.S. Nuclear Regulatory Commission, the U.S. Department of Energy, and industry (represented by the Electric Power Research Institute), an assessment of cable NDE methods was commissioned. Technologies include both bulk electrical measurements (Tan d, time domain reflectometry, frequency domain reflectometry (FDR), partial discharge, and other techniques) and local insulation measurement (indenter, dynamic mechanical analysis interdigital capacitance, infrared spectral measurement, etc.). This aging cable NDE program update reviews the full range of techniques but focuses on the most interesting test approaches that have a chance to be deployed in-situ, particularly including Tan d, FDR, and ultrasound methods that have been reviewed most completely in this progress period.

cable aging inspection↗

Utilization of Unmanned Aircraft Systems for Environmental Purposes at the Savannah River Site – 26578

Born in the 1950s, the Savannah River Plant was constructed as a plutonium and tritium production plant. As the Cold War era came and went, a change of direction was signaled when the name of the facility changed from Savannah River Plant to Savannah River Site (1989) – the main mission at Savannah River shifted from “production” to “cleanup.” The Department of Energy is responsible for managing the 310 square miles of land that is the Savannah River Site and the cleanup/remediation activities that occur. The Savannah River National Laboratory utilizes unmanned aircraft systems to assist with some of those environmental monitoring and remediation activities. One function of unmanned aircraft systems at the Savannah River National Laboratory is conducting aerial photography and videography. Various infrastructure evaluations have been performed with unmanned aircraft – facility rooftop inspections, water tower lock verifications, earthen dam surveys, etc. An unmanned aircraft system has been used for progress footage of remediation projects – Dunbarton Bay remediation, Saltstone Disposal Unit construction, etc. Thermal cameras on an unmanned aircraft system are used to help identify cracks/leaks in structures from vantage points not readily accessible by personnel. Virtual tours of different waste units are conducted with unmanned aircraft systems for Site groups and federal/state regulators to save costs and travel time. Additionally, advanced remote sensing technologies are used on unmanned aircraft systems at the Savannah River Site. Light Detection and Ranging uses laser pulses to measure distances to the Earth's surface or other targets to create highly detailed topographic maps that accurately portray terrain (e.g., elevation changes, slopes, and contours). Data collection with a Light Detection and Ranging unit mounted on an unmanned aircraft system is quick and efficient – large-area surveys are conducted in shorter time frames. Because Light Detection and Ranging can penetrate through foliage and vegetation to ground level, it is being used in conjunction with a watershed model to study the General Separations Area of the Site to determine stormwater flow volume and direction, monitor stream stability, and forecast river flow behavior. A hyperspectral camera captures a wide spectrum of electromagnetic wavelengths across numerous narrow bands, beyond what the human eye can see. It provides detailed spectral information about the objects or surfaces in an image, which can be used to identify and analyze materials based on their spectral signatures. A hyperspectral camera mounted on an unmanned aircraft system has been used at the Savannah River Site for non-destructive evaluation of concrete and concrete structures. Unmanned aircraft systems at the Savannah River Site are also used for the application of herbicide on identified rooftops. P-Reactor and R-Reactor are entombed nuclear reactors at the Savannah River Site. Unwanted vegetation is often present on these rooftops – over time roots can penetrate seams, cracks, and joints of the general roof and concrete caps, leading to water ingress and deterioration of the structural components. For time and cost efficiencies as well as in the interest of personnel safety, an unmanned aircraft is used to dispense herbicide on rooftop areas where vegetation is noticed to help alleviate the issues/hazards.

Lorier, Troy [Savannah River National Laboratory (↗

Integrated Nondestructive Assay Systems to Estimate Plutonium in Spent Fuel Assemblies

An integrated nondestructive assay (NDA) system combining active (neutron generator) and passive neutron detection and passive gamma (PG) detection is being analyzed in order to estimate the amount of plutonium, verify initial enrichment, burnup, and cooling time, and detect partial defects in a spent fuel assembly (SFA). Active signals are measured using the differential die-away (DDA), delayed neutron (DN), and delayed gamma (DG) techniques. Passive signals are measured using total neutron (TN) counts and both gross and spectral resolved gamma counts. To quantify how a system of several NDA techniques is expected to perform, all of the relevant NDA techniques listed above were simulated as a function of various reactor conditions such as initial enrichment, burnup, cooling time, assembly shuffling pattern, reactor operating conditions (including temperature, pressure, and the presence of burnable poisons) by simulating the NDA response for five sets of light water reactor assemblies. In this study, we compare the performance of several exploratory model-fitting options (including neural networks, adaptive regression with splines, iterative bias reduction smoothing, projection pursuit regression, and regression with quadratic terms and interaction terms) to relate data simulated with measurement and model error effects from various subsets of the NDA techniques to the total Pu mass. Isotope masses for SFAs and expected detector responses (DRs) for several NDA techniques are simulated using MCNP, and the DRs become inputs to the fitting process. Such responses include eight signals from DDA, one from DN, one from TN, and up to seven from PG; the DG signal will be examined separately. Results are summarized using the root-mean-squared estimation error for plutonium mass in held-out subsets of the data for a range of model and measurement error variances. Different simulation assumptions lead to different spent fuel libraries relating DRs to Pu mass. Some results for training with one library and testing with another library are also given.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Azomethines, isoxazole, N-substituted pyrazoles and pyrimidine containing curcumin derivatives: Urease inhibition and molecular modeling studies

Curcumin has shown large number of pharmacological properties against different phenotypes of various disease models. Different synthetic routes have been employed to develop its various derivatives for diverse biological functions. In this study, curcumin derived azomethine, isoxazole, pyrimidines and N-substituted pyrazoles were synthesized to investigate their urease enzyme inhibition. The structures of newly synthesized compounds were described by IR, MS, {sup 1}H NMR and {sup 13}C NMR spectral data. Urease enzyme inhibition was evaluated through in vitro assays in which compound 8b was found to be the most potent (IC{sub 50} = 2.44 ± 0.07 μM) among the tested compounds. The compounds with diazine ring system except the 4d showed better urease inhibition (IC{sub 50} = 11.43 ± 0.21–19.63 ± 0.28 μM) than the standard urease inhibitor thiourea (IC{sub 50} = 22.61 ± 0.23 μM). Similarly enzyme kinetics data revealed that compounds 3c-3e and 8b were competitive inhibitors with Ki values of 20.0, 19.87, 20.23 and 19.11 μM respectively while the compounds 4b, 4c and 4e were mixed type of inhibitors with Ki values 6.72, 19.69 and 6.72 μM respectively. Molecular docking studies were also performed to identify the plausible binding modes of the most active compounds. - Highlights: • Azomethines, Isoxazole, N-substituted pyrazoles and pyrimidine with curcumin scaffold were synthesized. • Anti-urease studies of target compounds were performed. • Molecular modeling of most active compounds at active site of urease. • Thiourea conjugated with curcumin showed excellent urease inhibition with IC{sub 50} = 2.44 ± 0.07 μM.

60 APPLIED LIFE SCIENCES↗

Neutrinos from type Ia supernovae: The gravitationally confined detonation scenario

Despite their use as cosmological distance indicators and their importance in the chemical evolution of galaxies, the unequivocal identification of the progenitor systems and explosion mechanism of normal type Ia supernovae (SNe Ia) remains elusive. The leading hypothesis is that such a supernova is a thermonuclear explosion of a carbon-oxygen white dwarf, but the exact explosion mechanism is still a matter of debate. Observation of a galactic SN Ia would be of immense value in answering the many open questions related to these events. One potentially useful source of information about the explosion mechanism and progenitor is the neutrino signal because the neutrinos from the different mechanisms possess distinct spectra as a function of time and energy. Here in this paper, we compute the expected neutrino signal from a gravitationally confined detonation (GCD) explosion scenario for a SN Ia and show how the flux at Earth contains features in time and energy unique to this scenario. We then calculate the expected event rates in the Super-K, Hyper-K, JUNO, DUNE, and IceCube detectors and find both Hyper-K and IceCube will see a few events for a GCD supernova at 1 kpc or closer, while Super-K, JUNO, and DUNE will see events if the supernova is closer than ~0.3 kpc. The distance and detector criteria needed to resolve the time and spectral features arising from the explosion mechanism, neutrino production, and neutrino oscillation processes are also discussed. The neutrino signal from the GCD is then compared with the signal from a deflagration-to-detonation transition (DDT) explosion model computed previously. We find the overall event rate is the most discriminating feature between the two scenarios followed by the event rate time structure. Using the event rate in the Hyper-K detector alone, the DDT can be distinguished from the GCD at 2σ if the distance to the supernova is less than 2.3 kpc for a normal mass ordering and 3.6 kpc for an inverted ordering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Zero-Field NMR and Millitesla-SLIC Spectra for >200 Molecules from Density Functional Theory and Spin Dynamics

NMR is usually performed at magnetic fields of 1 T and above to obtain sufficient sensitivity and spectral dispersion to identify chemicals based on chemical shifts and J couplings. At lower fields, the advent of hyperpolarization technologies and sensitive detectors can address sensitivity concerns. However, it remains disputed whether spectral signatures at zero and ultra-low fields are sufficient for chemical identification. Here, we report an all–electron DFT-based batch calculation of J-coupling constants, which are used to generate J coupling NMR spectra at zero field and 6.5 mT for over 200 small molecules. In the developed computational tool chain, we first used the all-electron FHI-aims code to calculate the molecular J couplings and chemical shifts. We then fed the calculated NMR parameters into the NMR simulation package SPINACH to simulate both heteronuclear J coupling spectra at zero-field, and homonuclear J coupling spectra as spin-lock induced crossing (SLIC) spectra at ultra-low field (6.5 mT). The resulting spectra demonstrate that zero and ultra-low field NMR spectra can represent unique identifiers of chemical structure for small molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The role of x-ray Swank factor in energy-resolving photon-counting imaging

Purpose: Energy-resolved x-ray imaging has the potential to improve contrast-to-noise ratio by measuring the energy of each interacting photon and applying optimal weighting factors. The success of energy-resolving photon-counting (EPC) detectors relies on the ability of an x-ray detector to accurately measure the energy of each interacting photon. However, the escape of characteristic emissions and Compton scatter degrades spectral information. This article makes the theoretical connection between accuracy and imprecision in energy measurements with the x-ray Swank factor for a-Se, Si, CdZnTe, and HgI{sub 2}-based detectors. Methods: For a detector that implements adaptive binning to sum all elements in which x-ray energy is deposited for a single interaction, energy imprecision is shown to depend on the Swank factor for a large element with x rays incident at the center. The response function for each converter material is determined using Monte Carlo methods and used to determine energy accuracy, Swank factor, and relative energy imprecision in photon-energy measurements. Results: For each material, at energies below the respective K edges, accuracy is close to unity and imprecision is only a few percent. Above the K-edge energies, characteristic emission results in a drop in accuracy and precision that depends on escape probability. In Si, and to some extent a-Se, Compton-scatter escape also degrades energy precision with increasing energy. The influence of converter thickness on energy accuracy and imprecision is modest for low-Z materials but becomes important when using high-Z materials at energies greater than the K-edge energies. Conclusions: Accuracy and precision in energy measurements by EPC detectors are determined largely by the energy-dependent x-ray Swank factor. Modest decreases in the Swank factor (5%-15%) result in large increases in relative imprecision (30%-40%).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A full-spectral Bayesian reconstruction approach based on the material decomposition model applied in dual-energy computed tomography

Purpose: Dual-energy computed tomography (DECT) makes it possible to get two fractions of basis materials without segmentation. One is the soft-tissue equivalent water fraction and the other is the hard-matter equivalent bone fraction. Practical DECT measurements are usually obtained with polychromatic x-ray beams. Existing reconstruction approaches based on linear forward models without counting the beam polychromaticity fail to estimate the correct decomposition fractions and result in beam-hardening artifacts (BHA). The existing BHA correction approaches either need to refer to calibration measurements or suffer from the noise amplification caused by the negative-log preprocessing and the ill-conditioned water and bone separation problem. To overcome these problems, statistical DECT reconstruction approaches based on nonlinear forward models counting the beam polychromaticity show great potential for giving accurate fraction images.Methods: This work proposes a full-spectral Bayesian reconstruction approach which allows the reconstruction of high quality fraction images from ordinary polychromatic measurements. This approach is based on a Gaussian noise model with unknown variance assigned directly to the projections without taking negative-log. Referring to Bayesian inferences, the decomposition fractions and observation variance are estimated by using the joint maximum a posteriori (MAP) estimation method. Subject to an adaptive prior model assigned to the variance, the joint estimation problem is then simplified into a single estimation problem. It transforms the joint MAP estimation problem into a minimization problem with a nonquadratic cost function. To solve it, the use of a monotone conjugate gradient algorithm with suboptimal descent steps is proposed.Results: The performance of the proposed approach is analyzed with both simulated and experimental data. The results show that the proposed Bayesian approach is robust to noise and materials. It is also necessary to have the accurate spectrum information about the source-detector system. When dealing with experimental data, the spectrum can be predicted by a Monte Carlo simulator. For the materials between water and bone, less than 5% separation errors are observed on the estimated decomposition fractions.Conclusions: The proposed approach is a statistical reconstruction approach based on a nonlinear forward model counting the full beam polychromaticity and applied directly to the projections without taking negative-log. Compared to the approaches based on linear forward models and the BHA correction approaches, it has advantages in noise robustness and reconstruction accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-Ray Absorbed, Broad-Lined, Red AGN and the Cosmic X-Ray Background

We have obtained XMM spectra for five red, 2MASS AGN, selected from a sample observed by Chandra to be X-ray bright and to cover a range of hardness ratios. Our results confirm the presence of substantial absorbing material in three sources which have optical classifications ranging from Type 1 to Type 2, with an intrinsically flat (hard) power law continuum indicated in the other two. The presence of both X-ray absorption and broad optical emission lines with the usual strength suggests either a small (nuclear) absorber or a favored viewing angle so as to cover the X-ray source but not the broad emission line region (BELR). A soft excess is detected in all three Type 1 sources. We speculate that this soft X-ray emission may arise in an extended region of ionized gas, perhaps linked with the polarized (scattered) light which is a feature of these sources. The spectral complexity revealed by XMM emphasizes the limitations of the low S/N Chandra data. Overall, the new XMM results strengthen our conclusions (Wilkes et al. 2002) that the observed X-ray continua of red AGN are unusually hard at energies greater than 2 keV. Whether due to substantial line-of-sight absorption or to an intrinsically hard or reflection-dominated spectrum, these 'red' AGN have an observed spectral form consistent with contributing significantly to the missing had absorbed population of the Cosmic X-ray Background (CXRB). When absorption and or reflection is taken into account, all these AGN have power law slopes typical of broad-line (Type 1) AGN (Gamma approximately 1.9). This appears to resolve the spectral paradox which for so long has existed between the CXRB and the AGN thought to be the dominant contributors. It also suggests two scenarios whereby Type 1 AGN/QSOs may be responsible for a significant fraction of the CXRB at energies above 2 keV: 1) X-ray absorbed AGN/QSOs with visible broad emission lines; 2) AGN/QSOs with complex spectra whose hardness greater than 2 keV is not detectable in the typically low S/N data of X-ray surveys. Even if absorption is present in only half of the population, the large number of 'red' AGN suggests a development of unification models, where the continuum source is surrounded, over a substantial solid angle, by the wind or atmosphere of an accretion disk/torus. X-ray observations of such AGN not only provide a check on the presence of absorption, but also a unique probe of the absorbing material. Improved information on their space density, in particular as a function of redshift, will soon be provided by Spitzer-Chandra wide area surveys, allowing better estimates of both the importance of red AGN to the full AGN population and their contribution to the CXRB.

Mushotzky, Richard↗