Search NASA⌕ Search

SEARCH · Search NASA

Results for “pixel array detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Centroid tracking with area array detectors

A computer program (ALGEVAL) has been developed to simulate the position estimating behavior of a centroid estimator algorithm using data typical of optical point spread function data recorded by an area array detector. Typical results are shown of varying detector properties and optical point spread function types. The detector parameters currently available for study include read noise mean value, dark current mean value and spatial variation, charge transfer efficiency and point spread function location, saturation level, signal level and pixel size. The program is capable of calculating any order centroid using an array size from 2 x 2 to 15 x 15 pixels. The output of the program is either a performance map, histogram data or tabluar data. A number of further developments are recommended.

Glavich, T. A.↗

Transparent Ceramic Garnet Gamma-Ray Spectrometer With Directionality

We have developed a handheld γ -ray spectrometer based on 1024 pixels, 2.8mm×2.8mm×6 mm in size, of gadolinium–yttrium–gallium–aluminum garnet (GYGAG) ((Gd,Y,Ce) 3 (Ga,Al) 5 O 12 ) ceramic scintillator (total of 48-cm 3 detector volume) coupled to silicon photodiode (SiPD) arrays. The SiPD arrays and readout ASIC, originally developed for medical imaging applications, have been adapted for portability in a lightweight box with heatsink and thermoelectric cooling. Custom readout firmware for γ-ray spectroscopy has been implemented, and a system user interface was developed that runs on an Android tablet. Here, we have optimized the processing of the GYGAG(Ce), the pixel optical coupling, and electronics readout parameters to obtain single pixel energy resolution as good as R(662keV)=3.1 % full-width at half-maximum and full device resolution with singles events from all pixels summed of 4.5%. When Compton-summed events are included, full-energy peak efficiency increases by ~2× , and R(662keV)=4.7 % is obtained for the full device. The pixelated architecture is leveraged to locate point sources of radiological materials using Compton imaging and active masking techniques. Directional detection of a 1 mCi Cs-137 source at 10 m can be made to ±10° in ~2 s.

42 ENGINEERING↗

TH-EF-207A-03: Photon Counting Implementation Challenges Using An Electron Multiplying Charged-Coupled Device Based Micro-CT System

Purpose: To successfully implement and operate a photon counting scheme on an electron multiplying charged-coupled device (EMCCD) based micro-CT system. Methods: We built an EMCCD based micro-CT system and implemented a photon counting scheme. EMCCD detectors use avalanche transfer registries to multiply the input signal far above the readout noise floor. Due to intrinsic differences in the pixel array, using a global threshold for photon counting is not optimal. To address this shortcoming, we generated a threshold array based on sixty dark fields (no x-ray exposure). We calculated an average matrix and a variance matrix of the dark field sequence. The average matrix was used for the offset correction while the variance matrix was used to set individual pixel thresholds for the photon counting scheme. Three hundred photon counting frames were added for each projection and 360 projections were acquired for each object. The system was used to scan various objects followed by reconstruction using an FDK algorithm. Results: Examination of the projection images and reconstructed slices of the objects indicated clear interior detail free of beam hardening artifacts. This suggests successful implementation of the photon counting scheme on our EMCCD based micro-CT system. Conclusion: This work indicates that it is possible to implement and operate a photon counting scheme on an EMCCD based micro-CT system, suggesting that these devices might be able to operate at very low x-ray exposures in a photon counting mode. Such devices could have future implications in clinical CT protocols. NIH Grant R01EB002873; Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

Infrared camera for 10-micron astronomy

An infrared imaging photometer employing a monolithic 32 x 32 pixel bismuth doped silicon charge injection device array is described. The device is primarily useful in the 8-13-micron atmospheric window. The detector is sufficiently sensitive to provide good performance on ground-based telescopes and promises to be very good for low background space flight operation.

Arens, J. F.↗

Detector requirements for space infrared astronomy

Requirements for background-limited (BLIP) detectors are discussed in terms of number of photons falling on each pixel, dark current, high detective quantum efficiencies, large numbers of pixels, and array size.

Wright, E. L.↗

Microcomputer control of infrared detector arrays

A microcomputer-based data-acquisition system has been developed for astronomical observing with two-dimensional infrared detector arrays. The hardware used is a 16-bit, 8086/8087 based system operating at 8 MHz. Data rates of up to 454,000 pixels per second are supported. The hardware is operated using interactive software which supports several modes of data acquisition.

Rossano, G. S.↗

Position sensitivity of MAMA detectors

The results of laboratory and telescopic measurements of the position sensitivity of a visible MAMA detector utilizing a 'coarse-fine' array are presented. The photometric accuracy of this detector was determined under point source illumination. It was found that computed centroid positions are accurate across the entire array to within 0.04 pixels.

Morgan, J. S.↗

The New Maia Detector System: Methods For High Definition Trace Element Imaging Of Natural Material

Motivated by the need for megapixel high definition trace element imaging to capture intricate detail in natural material, together with faster acquisition and improved counting statistics in elemental imaging, a large energy-dispersive detector array called Maia has been developed by CSIRO and BNL for SXRF imaging on the XFM beamline at the Australian Synchrotron. A 96 detector prototype demonstrated the capacity of the system for real-time deconvolution of complex spectral data using an embedded implementation of the Dynamic Analysis method and acquiring highly detailed images up to 77 M pixels spanning large areas of complex mineral sample sections.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design methodology: edgeless 3D ASICs with complex in-pixel processing for pixel detectors

The design methodology for the development of 3D integrated edgeless pixel detectors with in-pixel processing using Electronic Design Automation (EDA) tools is presented. A large area 3 tier 3D detector with one sensor layer and two ASIC layers containing one analog and one digital tier, is built for x-ray photon time of arrival measurement and imaging. A full custom analog pixel is 65μm x 65μm. It is connected to a sensor pixel of the same size on one side, and on the other side it has approximately 40 connections to the digital pixel. A 32 x 32 edgeless array without any peripheral functional blocks constitutes a sub-chip. The sub-chip is an indivisible unit, which is further arranged in a 6 x 6 array to create the entire 1.248cm x 1.248cm ASIC. Each chip has 720 bump-bond I/O connections, on the back of the digital tier to the ceramic PCB. All the analog tier power and biasing is conveyed through the digital tier from the PCB. The assembly has no peripheral functional blocks, and hence the active area extends to the edge of the detector. This was achieved by using a few flavors of almost identical analog pixels (minimal variation in layout) to allow for peripheral biasing blocks to be placed within pixels. The 1024 pixels within a digital sub-chip array have a variety of full custom, semi-custom and automated timing driven functional blocks placed together. The methodology uses a modified mixed-mode on-top digital implementation flow to not only harness the tool efficiency for timing and floor-planning but also to maintain designer control over compact parasitically aware layout. The methodology uses the Cadence design platform, however it is not limited to this tool.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing and characterization of an IR CBIRD FPA

High performance IR cameras are in great demand for a variety of applications, including defense (e.g. night vision, missile detection) and space (e.g. imaging at IR wavelengths). IR focal plane arrays (FPAs) are an essential component of IR cameras. An FPA is a collection of detectors at the focal plane of an imaging device, where each detector can be thought of a pixel in the image it is detecting. The FPA in this study is based on Complimentary Barrier Infrared Detectors (CBIRDs). The CBIRD FPA was tested by imaging flat black body targets at three different temperatures, 20ºC, 25ºC, and 30ºC, with images captured using SEIR software. The important figures of merit for an IR FPA, Noise Equivalent Difference Temperature (NEDT), Noise Equivalent Irradiance (NEI), detectivity (D*), responsivity, and quantum Efficiency (QE), were extracted from the image data for each individual detector using a MATLAB program, as was the array Modulation Transfer Function MTF. The test results show a mean NEDT of 16.98mK and an MTF of about 0.34 at the Nyquist frequency. Overall, the array performs well in the MWIR range and takes quality IR images.

Das, Tanya↗

CLAES focal plane array

The Cryogenic Limb Array Etalon Spectrometer for the NASA Upper Atmospheric Research Satellite uses solid-state focal plane arrays to detect emission from the earth's atmosphere over the IR wavelength range 3.5 to 13 microns. This paper discusses the design of the focal plane detector assembly and compares calculated performance with measurements. Measurements were made of focal plane noise and responsivity as functions of frequency (2 to 500 Hz) and temperature (12 to 19 K), pixel-to-pixel and across-array crosstalk, and linearity over a dynamic range of 100,000. The measurements demonstrate that the arrays satisfy the science requirements, and that, in general, there is reasonable agreement between the measurements and the analytical model.

Roche, A. E.↗

High Sensitivity Long-Wavelength Infrared QWIP Focal Plane Array Based Instrument for Remote Sensing of Icy Satellites

GaAs based Quantum Well Infrared Photodetector (QWIP) technology has shown remarkable success in advancing low cost, highly uniform, high-operability, large format multi-color focal plane arrays. QWIPs afford greater flexibility than the usual extrinsically doped semiconductor IR detectors. The wavelength of the peak response and cutoff can be continuously tailored over a range wide enough to enable light detection at any wavelength range between 6 and 20 micron. The spectral band-width of these detectors can be tuned from narrow (Deltalambda/lambda is approximately 10%) to wide (Deltalambda/lambda is approximately 40%) allowing various applications. Furthermore, QWIPs offer low cost per pixel and highly uniform large format focal plane arrays due to mature GaAs/AlGaAs growth and processing technologies. The other advantages of GaAs/AlGaAs based QWIPS are higher yield, lower l/f noise and radiation hardness (1.5 Mrad). In this presentation, we will discuss our recent demonstrations of 640x512 pixel narrow-band, broad-band, multi-band focal plane arrays, and the current status of the development of 1024x1024 pixel long-wavelength infrared QWIP focal plane arrays.

Gunapala, S.↗

Solid-state Image Sensor with Focal-plane Digital Photon-counting Pixel Array

A solid-state focal-plane imaging system comprises an NxN array of high gain. low-noise unit cells. each unit cell being connected to a different one of photovoltaic detector diodes, one for each unit cell, interspersed in the array for ultra low level image detection and a plurality of digital counters coupled to the outputs of the unit cell by a multiplexer(either a separate counter for each unit cell or a row of N of counters time shared with N rows of digital counters). Each unit cell includes two self-biasing cascode amplifiers in cascade for a high charge-to-voltage conversion gain (greater than 1mV/e(-)) and an electronic switch to reset input capacitance to a reference potential in order to be able to discriminate detection of an incident photon by the photoelectron (e(-))generated in the detector diode at the input of the first cascode amplifier in order to count incident photons individually in a digital counter connected to the output of the second cascade amplifier. Reseting the input capacitance and initiating self-biasing of the amplifiers occurs every clock cycle of an integratng period to enable ultralow light level image detection by the may of photovoltaic detector diodes under such ultralow light level conditions that the photon flux will statistically provide only a single photon at a time incident on anyone detector diode during any clock cycle.

Fossum, Eric R.↗

First Results On The Imaging Capabilities Of A DROID Array In The UV/Visible

Within the SCAM project of the European Space Agency the next step in the development of a cryogenic optical photon counting imaging spectrometer would be to increase the field of view using DROIDs (Distributed Read-Out Imaging Detector). We present the results of the first system test using an array of 60 360x33.5 {mu}m{sup 2} DROIDs in a 3x20 format for optical photon detection. This is an increase in area by a factor of 5.5 compared to the successful S-Cam 3 detector. The responsivity of the DROID array tested is too low for actual use on the telescope. However the spatial resolution of {approx}35 {mu}m is just above the size of a virtual pixel and imaging capabilities of the array can be demonstrated. With increasing responsivity this will improve, yielding a DROID array which can be used as an astronomical optical photon counting imaging spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-201-03: Coded Aperture Gamma-Ray Imaging Using Pixelated Semiconductor Detectors

Purpose: Improved localization of gamma-ray emissions from radiotracers is essential to the progress of nuclear medicine. Polaris is a portable, room-temperature operated gamma-ray imaging spectrometer composed of two 3×3 arrays of thick CdZnTe (CZT) detectors, which detect gammas between 30keV and 3MeV with energy resolution of <1% FWHM at 662keV. Compton imaging is used to map out source distributions in 4-pi space; however, is only effective above 300keV where Compton scatter is dominant. This work extends imaging to photoelectric energies (<300keV) using coded aperture imaging (CAI), which is essential for localization of Tc-99m (140keV). Methods: CAI, similar to the pinhole camera, relies on an attenuating mask, with open/closed elements, placed between the source and position-sensitive detectors. Partial attenuation of the source results in a “shadow” or count distribution that closely matches a portion of the mask pattern. Ideally, each source direction corresponds to a unique count distribution. Using backprojection reconstruction, the source direction is determined within the field of view. The knowledge of 3D position of interaction results in improved image quality. Results: Using a single array of detectors, a coded aperture mask, and multiple Co-57 (122keV) point sources, image reconstruction is performed in real-time, on an event-by-event basis, resulting in images with an angular resolution of ∼6 degrees. Although material nonuniformities contribute to image degradation, the superposition of images from individual detectors results in improved SNR. CAI was integrated with Compton imaging for a seamless transition between energy regimes. Conclusion: For the first time, CAI has been applied to thick, 3D position sensitive CZT detectors. Real-time, combined CAI and Compton imaging is performed using two 3×3 detector arrays, resulting in a source distribution in space. This system has been commercialized by H3D, Inc. and is being acquired for various applications worldwide, including proton therapy imaging R&D.

60 APPLIED LIFE SCIENCES↗

Second Generation Readout For Large Format Photon Counting Microwave Kinetic Inductance Detectors

We present the development of a second generation digital readout system for photon counting microwave kinetic inductance detector (MKID) arrays operating in the optical and near-infrared wavelength bands. Our system retains much of the core signal processing architecture from the first generation system but with a significantly higher bandwidth, enabling the readout of kilopixel MKID arrays. Each set of readout boards is capable of reading out 1024 MKID pixels multiplexed over 2 GHz of bandwidth; two such units can be placed in parallel to read out a full 2048 pixel microwave feedline over a 4 GHz–8 GHz band. As in the first generation readout, our system is capable of identifying, analyzing, and recording photon detection events in real time with a time resolution of order a few microseconds. Here, we describe the hardware and firmware, and present an analysis of the noise properties of the system. We also present a novel algorithm for efficiently suppressing IQ mixer sidebands to below −30 dBc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Issues in energy calibration, nonlinearity, and signal processing for gamma-ray microcalorimeter

Issues regarding the energy calibration of high dynamic range microcalorimeter detector arrays are presented with respect to new results from a minor actinide-mixed oxide radioactive source. The need to move to larger arrays of such detectors necessitates the implementation of automated analysis procedures, which turn out to be nontrivial due to complex calibration shapes and pixel-to-pixel variability. Some possible avenues for improvement, including a more physics-based calibration procedure, are suggested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗