Search NASA⌕ Search

SEARCH · Search NASA

Results for “preforms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Comparison of Ti-Zr-V nonevaporable getter films deposited using alloy or twisted wire sputter-targets

A comparison of the performance of nonevaporable getter (NEG) films deposited using two different types of targets has been made to find the one that has the best pumping properties. For the first time, the NEG coating was deposited using a preformed Ti-Zr-V alloy target. The NEG film characterization and pumping properties have been studied in comparison with a film deposited using the commonly used three-wire twisted target. It was demonstrated that the alloy target produces a NEG coating with uniform composition both laterally and in depth. The composition of the film was found to be the same as the target. Film topography and microstructure with 5 nm grain sizes were found to be the same for both targets. The main result is that the activation temperature of the NEG coating deposited using the Ti-Zr-V alloy target is 160 deg. C, which is 20 deg. C lower than for NEG coatings deposited using three twisted wires.

36 MATERIALS SCIENCE↗

Automatic tracking of implanted fiducial markers in cone beam CT projection images

Purpose: This paper describes a novel method for simultaneous intrafraction tracking of multiple fiducial markers. Although the proposed method is generic and can be adopted for a number of applications including fluoroscopy based patient position monitoring and gated radiotherapy, the tracking results presented in this paper are specific to tracking fiducial markers in a sequence of cone beam CT projection images. Methods: The proposed method is accurate and robust thanks to utilizing the mean shift and random sampling principles, respectively. The performance of the proposed method was evaluated with qualitative and quantitative methods, using data from two pancreatic and one prostate cancer patients and a moving phantom. The ground truth, for quantitative evaluation, was calculated based on manual tracking preformed by three observers. Results: The average dispersion of marker position error calculated from the tracking results for pancreas data (six markers tracked over 640 frames, 3840 marker identifications) was 0.25 mm (at iscoenter), compared with an average dispersion for the manual ground truth estimated at 0.22 mm. For prostate data (three markers tracked over 366 frames, 1098 marker identifications), the average error was 0.34 mm. The estimated tracking error in the pancreas data was < 1 mm (2 pixels) in 97.6% of cases where nearby image clutter was detected and in 100.0% of cases with no nearby image clutter. Conclusions: The proposed method has accuracy comparable to that of manual tracking and, in combination with the proposed batch postprocessing, superior robustness. Marker tracking in cone beam CT (CBCT) projections is useful for a variety of purposes, such as providing data for assessment of intrafraction motion, target tracking during rotational treatment delivery, motion correction of CBCT, and phase sorting for 4D CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-CAMPUS-I-01: Nanometric Organic Photovoltaic Thin Film X-Ray Detectors for Clinical KVp Beams

Purpose: To fabricate and test nanometric organic photovoltaic (OPV) cells made of various active-layer/electrode thicknesses and sizes; to determine the optimal material combinations and geometries suitable for dose measurements in clinical kilovoltage x-ray beams. Methods: The OPV consisted of P3HT:PCBM photoactive materials sandwiched between aluminum and Indium Tin Oxide (ITO) electrodes. Direct conversion of xrays in the active layer composed of donor and acceptor semiconducting organic materials generated signal in photovoltaic mode (without external voltage bias). OPV cells were fabricated with different active layer thicknesses (150, 270, 370 nm) and electrode areas (0.4, 0.7, 0.9, 1.4, 2.6 cm{sup 2}). A series of experiments were preformed in the energy range of 60–150 kVp. The net current per unit area (nA/cm{sup 2}) was measured using 200 mAs time-integrated beam current. Results: The net OPV current as function of beam energy (kVp) was proportional to ∼E{sup 0,4} {sup 5} when adjusted for beam output. The best combination of parameters for these cells was 270 nm active layer thicknesses for 0.7 cm{sup 2} electrode area. The measured current ranged from 0.69 to 2.43 nA/cm{sup 2} as a function of x-ray energy between 60 and 150 kVp, corresponding to 0.09 – 0.06 nA/cm{sup 2}/mGy, respectively, when adjusted for the beam output. Conclusion: The experiments indicate that OPV detectors possessing 270 nm active layer and 0.7 cm{sup 2} Al electrode areas have sensitivity by a factor of 2.5 greater than commercial aSi thin film PV. Because OPV can be made flexible and they do not require highvoltage bias supply, they open the possibility for using as in-vivo detectors in radiation safety in x-ray imaging beams.

60 APPLIED LIFE SCIENCES↗

SU-E-I-55: The Contribution to Skin Dose Due to Scatter From the Patient Table and the Head Holder During Fluoroscopy

Purpose: To determine contributions to skin dose due to scatter from the table and head holder used during fluoroscopy, and also to explore alternative design material to reduce the scatter dose. Methods: Measurements were made of the primary and scatter components of the xray beam exiting the patient table and a cylindrical head holder used on a Toshiba Infinix c-arm unit as a function of kVp for the various beam filters on the machine and for various field sizes. The primary component of the beam was measured in air with the object placed close to the x-ray tube with an air gap between it and a 6 cc parallel-plate ionization chamber and with the beam collimated to a size just larger than the chamber. The primary plus scatter radiation components were measured with the object moved to a position in the beam next to the chamber for larger field sizes. Both sets of measurements were preformed while keeping the source-to-chamber distance fixed. The scatter fraction was estimated by taking the ratio of the difference between the two measurements and the reading that included both primary and scatter. Similar measurements were also made for a 2.3 cm thick Styrofoam block which could substitute for the patient support. Results: The measured scatter fractions indicate that the patient table as well as the head holder contributes an additional 10–16% to the patient entrance dose depending on field size. Forward scatter was reduced with the Styrofoam block so that the scatter fraction was about 4–5%. Conclusion: The results of this investigation demonstrated that scatter from the table and head holder used in clinical fluoroscopy contribute substantially to the skin dose. The lower contribution of scatter from Styrofoam suggests that there is an opportunity to redesign patient support accessories to reduce the skin dose. Partial support from NIH grant R01EB002873 and Toshiba Medical Systems Corporation Equipment Grant.

60 APPLIED LIFE SCIENCES↗

SU-E-T-413: Examining Acquisition Rate for Using MatriXX Ion Chamber Array to Measure HDR Brachytherapy Treatments

Purpose: There are unique obstacles to implementing the MatriXX ionchamber array as a QA tool in Brachytherapy given that the device is designed for use in the MV energy range. One of the challenges we investigate is the affect of acquisition rates on dose measurement accuracy for HDR treatment plans. Methods: A treatment plan was optimized in Oncentra Brachy TPS to deliver a planar dose to a 5×5cm region at 10mm depth. The applicator was affixed to the surface of the MatriXX array. The plan was delivered multiple times using a Nucleatron HDR afterloader with a 2.9Ci Ir192 source. For each measurement the sampling rate of the MatriXX movie mode was varied (30ms and 500ms). This experiment was repeated with identical parameters, following a source exchange, with an 11.2Ci Ir192 source. Finally, a single snap measurement was acquired. Analysis was preformed to evaluate the fidelity of the dose delivery for each iteration of the experiment. Evaluation was based on the comparison between the measured and TPS predicted dose. Results: Higher sample rates induce a greater discrepancy between the predicted and measured dose. Delivering the plan using a lower activity source also produced greater discrepancy in the measurement due to the increased delivery time. Analyzing the single snap measurement showed little difference from the 500ms integral dose measurement. Conclusion: The advantage of using movie mode for HDR treatment delivery QA is the ability for real time source tracking in addition to dose measurement. Our analysis indicates that 500ms is an optimal frame rate.

61 RADIATION PROTECTION AND DOSIMETRY↗

Seeded growth of single-crystal two-dimensional covalent organic frameworks

Polymerizing monomers into periodic two-dimensional (2D) networks provides structurally precise, layered macromolecular sheets that exhibit desirable mechanical, optoelectrotronic, and molecular transport properties. 2D covalent organic frameworks (COFs) offer broad monomer scope but are generally isolated as powders comprised of aggregated nanometer-scale crystallites. Here we control 2D COF formation using a two-step procedure, in which monomers are added slowly to pre-formed nanoparticle seeds. The resulting 2D COFs are isolated as single-crystalline, micron-sized particles. Transient absorption spectroscopy of the dispersed COF nanoparticles provides two to three orders of magnitude improvement in signal quality relative to polycrystalline powder samples and suggests exciton diffusion over longer length scales than those obtained through previous approaches. These findings will enable a broad exploration of synthetic 2D polymer structures and properties.

Evans, Austin M. (ORCID:0000000235972454)↗

Hepatitis B Virus Capsids Have Diverse Structural Responses to Small-Molecule Ligands Bound to the Heteroaryldihydropyrimidine Pocket

Though the hepatitis B virus (HBV) core protein is an important participant in many aspects of the viral life cycle, its best-characterized activity is self-assembly into 240-monomer capsids. Small molecules that target core protein (core protein allosteric modulators [CpAMs]) represent a promising antiviral strategy. To better understand the structural basis of the CpAM mechanism, we determined the crystal structure of the HBV capsid in complex with HAP18. HAP18 accelerates assembly, increases protein-protein association more than 100-fold, and induces assembly of nonicosahedral macrostructures. In a preformed capsid, HAP18 is found at quasiequivalent subunit-subunit interfaces. In a detailed comparison to the two other extant CpAM structures, we find that the HAP18-capsid structure presents a paradox. Whereas the two other structures expanded the capsid diameter by up to 10 Å, HAP18 caused only minor changes in quaternary structure and actually decreased the capsid diameter by ~3 Å. These results indicate that CpAMs do not have a single allosteric effect on capsid structure. We suggest that HBV capsids present an ensemble of states that can be trapped by CpAMs, indicating a more complex basis for antiviral drug design. Hepatitis B virus core protein has multiple roles in the viral life cycle—assembly, compartment for reverse transcription, intracellular trafficking, and nuclear functions—making it an attractive antiviral target. Core protein allosteric modulators (CpAMs) are an experimental class of antivirals that bind core protein. The most recognized CpAM activity is that they accelerate core protein assembly and strengthen interactions between subunits. In this study, we observe that the CpAM-binding pocket has multiple conformations. We compare structures of capsids cocrystallized with different CpAMs and find that they also affect quaternary structure in different ways. Furthermore, these results suggest that the capsid “breathes” and is trapped in different states by the drug and crystallization. Understanding that the capsid is a moving target will aid drug design and improve our understanding of HBV interaction with its environment.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of Mullite Formation in the Core Glass of a Chromium-Doped Aluminosilicate Fiber

Using MCVD, we have produced optically active fibers with a glass-ceramic core containing mullite, 3Al{sub 2}O{sub 3} · 2SiO{sub 2}, as a major crystalline phase. Thermodynamic prediction of mullite formation conditions has been supplemented by thermal analysis and X-ray diffraction characterization of preform core samples, and fiber heat treatment (annealing) conditions have been established. Luminescence measurements for the fibers annealed under optimal conditions demonstrate that optically active chromium has a crystalline local environment.

36 MATERIALS SCIENCE↗

Attractive Hubbard model: Homogeneous Ginzburg–Landau expansion and disorder

We derive a Ginzburg–Landau (GL) expansion in the disordered attractive Hubbard model within the combined Nozieres–Schmitt-Rink and DMFT+Σ approximation. Restricting ourselves to the homogeneous expansion, we analyze the disorder dependence of GL expansion coefficients for a wide range of attractive potentials U, from the weak BCS coupling region to the strong-coupling limit, where superconductivity is described by Bose–Einstein condensation (BEC) of preformed Cooper pairs. We show that for the a semielliptic “bare” density of states of the conduction band, the disorder influence on the GL coefficients A and B before quadratic and quartic terms of the order parameter, as well as on the specific heat discontinuity at the superconducting transition, is of a universal nature at any strength of the attractive interaction and is related only to the general widening of the conduction band by disorder. In general, disorder growth increases the values of the coefficients A and B, leading either to a suppression of the specific heat discontinuity (in the weak-coupling limit), or to its significant growth (in the strong-coupling region). However, this behavior actually confirms the validity of the generalized Anderson theorem, because the disorder dependence of the superconducting transition temperature T{sub c}, is also controlled only by disorder widening of the conduction band (density of states).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Repetitively rated plasma relativistic microwave oscillator with a controllable frequency in every pulse

A repetitively rated microwave oscillator whose frequency can be varied electronically from pulse to pulse in a predetermined manner is created for the first time. The microwave oscillator has a power on the order of 10{sup 8} W and is based on the Cherenkov interaction of a high-current relativistic electron beam with a plasma preformed before each pulse. Electronic control over the plasma properties allows one to arbitrarily vary the microwave frequency from pulse to pulse at a pulse repetition rate of up to 50 Hz.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Control over the radiation spectrum of a microwave plasma relativistic oscillator

General features of the operation of microwave oscillators based on the Cherenkov resonance interaction of a high-current relativistic electron beam with a preformed plasma are considered. Emphasis is placed on the presence of longitudinal modes of the plasma-beam resonator that make it possible to tune the radiation frequency. Methods by which the radiation frequency can be varied severalfold continuously or in discrete controlled steps and the width of the spectrum of simultaneously generated frequencies can be changed substantially are described. The results of numerical simulations are compared with available experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microwave Giant Magnetoresistance in [CoFe/Cu]{sub n} Superlattices with Record-High Magnetoresistance

Microwave giant magnetoresistance in [CoFe/Cu]{sub n} nanostructures is studied in the millimeter-wave range. Measurements are preformed for superlattices with the maximum magnetoresistive effect. The field dependences of transmission and reflection coefficients are determined. Record-high (up to 80%) variations of the transmission coefficient are obtained.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Measurements of multiplicity fluctuations of identified hadrons in inelastic proton–proton interactions at the CERN Super Proton Synchrotron

Measurements of multiplicity fluctuations of identified hadrons produced in inelastic p+p interactions at 31, 40, 80, and 158 $\text {Ge}\text {V}/c$ beam momentum are presented. Three different measures of multiplicity fluctuations are used: the scaled variance $\omega $ and strongly intensive measures $\Sigma $ and $\Delta $. These fluctuation measures involve second and first moments of joint multiplicity distributions. Data analysis is preformed using the Identity method which corrects for incomplete particle identification. Strongly intensive quantities are calculated in order to allow for a direct comparison to corresponding results on nucleus–nucleus collisions. The results for different hadron types are shown as a function of collision energy. A comparison with predictions of string-resonance Monte-Carlo models: Epos, Smash and Venus, is also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advanced Manufacturing Basic Entity Relationships Ontology

A data ontology defined using the W3C Web Ontology Language (OWL) format. It defines classes and attributes for objects directly implicated in manufacturing such as materials, preform geometries, and manufacturing processes and settings. It also includes classes to describe entities that are instrumental to making digital twins and performing predictive activities on manufacturing data such as designs of experiment and predictive models.

Harris, BrennanKay↗

The Ice Particle and Aggregate Simulator (IPAS). Part III: Verification and Analysis of Ice–Aggregate and Aggregate–Aggregate Collection for Microphysical Parameterization

Abstract The Ice Particle and Aggregate Simulator (IPAS) is used to theoretically represent the aggregation process of ice crystals. Aggregates have a variety of formations based on initial ice particle size, shape, and falling orientation, all of which influence water phase partitioning. Aggregate dimensional properties and density changes are calculated for monomer–monomer (MON–MON), monomer–aggregate (MON–AGG), and aggregate–aggregate (AGG–AGG) collection to be used by ice-microphysical models for improvement in aggregation parameterizations. Aggregates are chosen from a database of 9 744 000 preformed combinations to be further collected (see Part II). AGG–AGG collection results in more extreme and a smaller range of aggregate aspect ratios than MON–AGG collection. A majority of aggregates are closer to prolate than oblate spheroids, regardless of collection type, except for quasi-horizontally oriented particles that have extreme aspect ratios to begin with. MON–AGG collection frequently results in an increase in density upon collection, whereas MON–MON and AGG–AGG collection almost always result in particle density decreases, with extreme reductions near 99% for MON–MON collection. MON–MON collection results in the greatest decreases in density but then quickly becomes unaffected by the addition of more monomers due to inherent size differences between monomers and aggregates. Finally, a holistic analysis to in situ observations of cloud particle images is presented. IPAS 2D aspect ratios surround a median value of 0.6 and closely follow that of previous studies while varying by no more than ≈12% on average from observed aggregates.

54 ENVIRONMENTAL SCIENCES↗

Development and Characterization of Healable Carbon Fiber Composites with a Reversibly Cross Linked Polymer

Carbon fiber reinforced polymer (CFRP) laminates with remendable cross-linked polymeric matrices were fabricated using a modified resin transfer mold (RTM) technique. The healable composite resin, bis-maleimide tetrafuran (2MEP4F), was synthesized by mixing two monomers, furan (4F) and maleimide (2MEP), at elevated temperatures. The fast kinetic rate of the reaction of polymer constituents requires a fast injection of the healable resin into the carbon fiber preform. The polymer viscosity as a function of time and temperature was experimentally quantified in order to optimize the fabrication of the composite material and to guarantee a uniform flow of the resin through the reinforcement. The method was validated by characterizing the thermo-mechanical properties of the polymerized 2MEP4F. Additionally, the thermo-mechanical properties of the remendable CFRP material were studied.

36 MATERIALS SCIENCE↗

SWAP-Assembler: scalable and efficient genome assembly towards thousands of cores

Background: There is a widening gap between the throughput of massive parallel sequencing machines and the ability to analyze these sequencing data. Traditional assembly methods requiring long execution time and large amount of memory on a single workstation limit their use on these massive data. Results: This paper presents a highly scalable assembler named as SWAP-Assembler for processing massive sequencing data using thousands of cores, where SWAP is an acronym for Small World Asynchronous Parallel model. In the paper, a mathematical description of multi-step bi-directed graph (MSG) is provided to resolve the computational interdependence on merging edges, and a highly scalable computational framework for SWAP is developed to automatically preform the parallel computation of all operations. Graph cleaning and contig extension are also included for generating contigs with high quality. Experimental results show that SWAP-Assembler scales up to 2048 cores on Yanhuang dataset using only 26 minutes, which is better than several other parallel assemblers, such as ABySS, Ray, and PASHA. Results also show that SWAP-Assembler can generate high quality contigs with good N50 size and low error rate, especially it generated the longest N50 contig sizes for Fish and Yanhuang datasets. Conclusions: In this paper, we presented a highly scalable and efficient genome assembly software, SWAPAssembler. Compared with several other assemblers, it showed very good performance in terms of scalability and contig quality. This software is available at: https://sourceforge.net/projects/swapassembler

59 BASIC BIOLOGICAL SCIENCES↗

Low- and high-order nonlinear optical properties of BaTiO{sub 3} and SrTiO{sub 3} nanoparticles

We present the studies of the third- and higher-order nonlinear optical processes in barium titanate (BaTiO{sub 3}) and strontium titanate (SrTiO{sub 3}) nanoparticles. We measured the nonlinear refractive indices and nonlinear absorption coefficients of the BaTiO{sub 3} and SrTiO{sub 3} nanoparticles dissolved in ethylene glycol using the 790 nm fs and ps pulses. The high-order harmonic generation up to the 39th order was achieved in the BaTiO{sub 3} and SrTiO{sub 3} nanoparticles-contained plumes when the femtosecond radiation propagated through the preformed plasma. The 1x10{sup -6} and 4x10{sup -6} high-order harmonic efficiencies at the plateau region were achieved in the cases of the BaTiO{sub 3} and SrTiO{sub 3} nanoparticles-contained plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗