Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiometer calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Retrieval of ocean surface parameters from the scanning multifrequency microwave radiometer (SMMR) on the Nimbus-7 satellite

Sea-surface temperature retrievals have been tested on 2 months of Nimbus-7 scanning multichannel microwave radiometer data. Using the prelaunch versions of the instrument calibration and geophysical parameter retrieval algorithms the initial results were poor. Improved algorithms produced substantially better results. It appears that at least for the night-Southern Hemisphere portion of the Nimbus-7 orbit, a rms measurement accuracy of 1.45 C has been achieved. Similar tests with wind speed retrievals yield an accuracy of 2.7 m/s rms with no substantial differences between day and night measurements but limited by availability of surface observations to the Northern Hemisphere. Moreover, it appears that the retrieved wind speed is more nearly related to the square of the wind observed at the surface than to the wind itself.

Wilheit, T. T., Jr.↗

Satellite measurement of aerosol mass over land

The estimation of aerosol optical thickness and mass from satellite observations over land is demonstrated using data from the GOES Visible/IR Spin-Scan Radiometer for the eastern U.S. The post-launch calibration technique is described; the algorithm used to derive optical thickness from the radiance of scattered sunlight (by means of a radiative-transfer model in which the optical characteristics of the aerosol are assumed) is presented; and data on aerosol S for July 31, 1980 are analyzed. The results are presented in a series of graphs and maps and compared with ground-based data. The errors in the optical thickness and columnar mass are estimated as 15 and 40 percent, respectively, and the need for independent-data-set validation of satellite-based mass, transport, and divergence values is indicated.

Fraser, R. S.↗

A few parts in 10 to the 8th geodetic baseline repeatablity in the Gulf of California using the Global Positioning System

GPS geodetic measurements of 350-650 km baselines across the Pacific-North America plate boundary in the Gulf of California are presented. The analysis employs a four-station U.S. fiducial network and combined carrier phase and pseudorange data. Water vapor radiometer data at the Gulf sites are used to calibrate the GPS signal for wet tropospheric path delays. Residual tropospheric delays are modeled as first-order exponentially correlated stochastic processes. The measurement precision for horizontal components is a few parts in 10 to the 8th or better.

Tralli, David M.↗

Earth Radiation Imbalance from a Constellation of 66 Iridium Satellites: Technological Aspects

Iridium Communications Inc. is launching a new generation of polar orbiting communication satellites in 2015-2017. Iridium will provide a hosted payload bay on each of the 66 satellites (plus 6 in-space spares). This offers the potential for a paradigm shift in the way we measure Earth radiation imbalance from space, as well as massive cost savings. Because the constellation provides 24/7 global coverage, there is no need to account for diurnal cycle via extrapolations from uncalibrated narrowband geostationary imagers. And the spares can be rolled over to view the Sun and deep space, then transfer their calibration to the other members of the constellation during the frequent cross-overs. In part using simulations of the constellation viewing realistic Earth scenes, this presentation will address the technological aspects of such a constellation: (1) the calibration strategy; (2) the highly-accurate and stable radiometers for measuring outgoing flux; and (3) the GRACE-inspired algorithms for representing the outgoing flux field in spherical harmonics and thus achieving rv500-km spatial resolution and two-hour temporal resolution.

Wiscombe, W.↗

Climate Absolute Radiance and Refractivity Observatory (CLARREO)

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) is a mission, led and developed by NASA, that will measure a variety of climate variables with an unprecedented accuracy to quantify and attribute climate change. CLARREO consists of three separate instruments: an infrared (IR) spectrometer, a reflected solar (RS) spectrometer, and a radio occultation (RO) instrument. The mission will contain orbiting radiometers with sufficient accuracy, including on orbit verification, to calibrate other space-based instrumentation, increasing their respective accuracy by as much as an order of magnitude. The IR spectrometer is a Fourier Transform spectrometer (FTS) working in the 5 to 50 microns wavelength region with a goal of 0.1 K (k = 3) accuracy. The FTS will achieve this accuracy using phase change cells to verify thermistor accuracy and heated halos to verify blackbody emissivity, both on orbit. The RS spectrometer will measure the reflectance of the atmosphere in the 0.32 to 2.3 microns wavelength region with an accuracy of 0.3% (k = 2). The status of the instrumentation packages and potential mission options will be presented.

Leckey, John P.↗

Product of the SNPP VIIRS SD Screen Transmittance and the SD BRDF (RSB) From Both Yaw Maneuver and Regular On-Orbit Data

To assure data quality, the Earth-observing Visible Infrared Imaging Radiometer Suite (VIIRS) regularly performs on-orbit radiometric calibrations of its 22 spectral bands. The primary calibration radiance source for the reflective solar bands (RSBs) is a sunlit solar diffuser (SD). During the calibration process, sunlight goes through a perforated plate (the SD screen) and then strikes the SD. The SD scattered sunlight is used for the calibration, with the spectral radiance proportional to the product of the SD screen transmittance and the SD bidirectional reflectance distribution function (BRDF). The BRDF is decomposed to the product of its value at launch and a numerical factor quantifying its change since launch. Therefore, the RSB calibration requires accurate knowledge of the product of the SD screen transmittance and the BRDF (RSB; launch time). Previously, we calculated the product with yaw maneuver data and found that the product had improved accuracy over the prelaunch one. With both yaw maneuver and regular on orbit data, we were able to improve the accuracy of the SDSM screen transmittance and the product for the solar diffuser stability monitor SD view. In this study, we use both yaw maneuver and a small portion of regular on-orbit data to determine the product for the RSB SD view.

Lei, Ning↗

Assessment of Satellite-Derived Surface Reflectances by NASA's CAR Airborne Radiometer over Railroad Valley, Nevada

CAR (Cloud Absorption Radiometer) is a multi-angular and multi-spectral airborne radiometer instrument, whose radiometric and geometric characteristics are well calibrated and adjusted before and after each flight campaign. CAR was built by NASA (National Aeronautics and Space Administration) in 1984. On 16 May 2008, a CAR flight campaign took place over the well-known calibration and validation site of Railroad Valley in Nevada (38.504 deg N, 115.692 deg W).The campaign coincided with the overpasses of several key EO (Earth Observation) satellites such as Landsat-7, Envisat and Terra. Thus, there are nearly simultaneous measurements from these satellites and the CAR airborne sensor over the same calibration site. The CAR spectral bands are close to those of most EO satellites. CAR has the ability to cover the whole range of azimuth view angles and a variety of zenith angles depending on altitude and, as a consequence, the biases seen between satellite and CAR measurements due to both unmatched spectral bands and unmatched angles can be significantly reduced. A comparison is presented here between CARs land surface reflectance (BRF or Bidirectional Reflectance Factor) with those derived from Terra/MODIS (MOD09 and MAIAC), Terra/MISR, Envisat/MERIS and Landsat-7. In this study, we utilized CAR data from low altitude flights (approx. 180 m above the surface) in order to minimize the effects of the atmosphere on these measurements and then obtain a valuable ground-truth data set of surface reflectance. Furthermore, this study shows that differences between measurements caused by surface heterogeneity can be tolerated, thanks to the high homogeneity of the study site on the one hand, and on the other hand, to the spatial sampling and the large number of CAR samples. These results demonstrate that satellite BRF measurements over this site are in good agreement with CAR with variable biases across different spectral bands. This is most likely due to residual aerosol effects in the EO derived reflectances.

calibration↗

The Global Satellite Precipitation Constellation: Current Status and Future Requirements

To address the need to map precipitation on a global scale a collection of satellites carrying passive microwave (PMW) radiometers has grown over the last 20 years to form a constellation of about 10-12 sensors at any one time. Over the same period, a broad range of science and user communities has become increasingly dependent on the precipitation products provided by these sensors. The constellation presently consists of both conical and cross-track scanning precipitation-capable multi-channel instruments, many of which are beyond their operational and design lifetime but continue to operate through the cooperation of the responsible agencies. The Group on Earth Observations and the Coordinating Group for Meteorological Satellites (CGMS), among other groups, have raised the issue of how a robust, future precipitation constellation should be constructed. The key issues of current and future requirements for the mapping of global precipitation from satellite sensors can be summarised as providing: 1) sufficiently fine spatial resolutions to capture precipitation-scale systems and reduce the beam-filling effects of the observations; 2) a wide channel diversity for each sensor to cover the range of precipitation types, characteristics and intensities observed across the globe; 3) an observation interval that provides temporal sampling commensurate with the variability of precipitation; and 4) precipitation radars and radiometers in low inclination orbit to provide a consistent calibration source, as demonstrated by the first two spaceborne radar/radiometer combinations on the Tropical Rainfall Measuring Mission (TRMM) and Global Precipitation Measurement (GPM) mission Core Observatory (CO). These issues are critical in determining the direction of future constellation requirements, while preserving the continuity of the existing constellation necessary for long-term climate-scale studies.

Precipitation↗

New Absolute Cavity Pyrgeometer equation by application of Kirchhoff's law and adding a convection term

An equation for the Absolute Cavity Pyrgeometer (ACP) is derived from application of Kirchhoff's law and the addition of a convection term to account for the thermopile being open to the environment, unlike a domed radiometer. The equation is then used to investigate four methods to characterise key instrumental parameters using laboratory and field measurements. The first uses solar irradiance to estimate the thermopile responsivity, the second uses a minimisation method that solves for the thermopile responsivity and transmission of the cavity, and the third and fourth revisit the Reda et al. (2012) linear least squares calibration technique. Data were collected between January and November 2020, when the ACP96 and two IRIS radiometers monitoring terrestrial irradiances were available. The results indicate good agreement with IRIS irradiances using the new equation. The analysis also indicates that while the thermopile responsivity, concentrator transmission and emissivity of an ACP can be determined independently, as an open instrument, the impact of the convection term is minor in steady-state conditions but significant when the base of the instrument is being subjected to rapid artificial cooling or heating. Using laboratory characterisation of the transmission and emissivity, together with use of an estimated solar calibration of the thermopile, generated mean differences of less than 1.5 Wm -2 to the two IRIS radiometers. A minimisation method using each IRIS radiometer as the reference also provided similar results, and the derived thermopile responsivity was within 0.3 µV W -1 m 2 of the solar-calibration-derived infrared responsivity estimate of 10.5 µV W -1 m 2 estimated using a nominal solar calibration and provide irradiances within ±2 % of the terrestrial irradiance measured by the reference pyrgeometers traceable to the International System of Units (SI). The calibration method using linear least squares regression introduced by Reda et al. (2012) that relies on rapid cooling of the ACP base but utilising the new equation was found to produce consistent results but was dependent on the assumed temperature of the air above the thermopile. This study demonstrates the potential of the ACP as another independent reference radiometer for terrestrial irradiance once the magnitude of the convection coefficient and any potential variations in it have been resolved.

47 OTHER INSTRUMENTATION↗

View-limiting shrouds for insolation radiometers

Insolation radiometers (normal incidence pyrheliometers) are used to measure the solar radiation incident on solar concentrators for calibrating thermal power generation measurements. The measured insolation value is dependent on the atmospheric transparency, solar elevation angle, circumsolar radiation, and radiometer field of view. The radiant energy entering the thermal receiver is dependent on the same factors. The insolation value and the receiver input will be proportional if the concentrator and the radiometer have similar fields of view. This report describes one practical method for matching the field of view of a radiometer to that of a solar concentrator. The concentrator field of view can be calculated by optical ray tracing methods and the field of view of a radiometer with a simple shroud can be calculated by using geometric equations. The parameters for the shroud can be adjusted to provide an acceptable match between the respective fields of view. Concentrator fields of view have been calculated for a family of paraboloidal concentrators and receiver apertures. The corresponding shroud parameters have also been determined.

Dennison, E. W.↗

Optical design of an imaging spectral radiometer for earth resources applications.

Description of the optics, thermal compensation measures, and calibration procedures for a scanning imaging spectroradiometer to be used in earth resources sensing applications. The spectral range covered extends from 4000 to 8500 A. Two possible modes of operation include (1) a high-spatial-resolution terrestrial survey mode with moderate spectral resolution, and (2) a high-spectral-resolution ocean survey mode with decreased spatial resolution. Two high-aperture f/1.4 objective lenses (providing fields of view of 10 and 25 deg) are interchangeable to give added flexibility in planning experiments with this instrument. A diffraction grating disperses the spectrum which is then scanned by the image sensor.

Harris, T. I.↗

Improved Calibration through SMAP RFI Change Detection

Anthropogenic Radio-Frequency Interference (RFI) drove both the SMAP (Soil Moisture Active Passive) microwave radiometer hardware and Level 1 science algorithm designs to use new technology and techniques for the first time on a spaceflight project. Care was taken to provide special features allowing the detection and removal of harmful interference in order to meet the error budget. Nonetheless, the project accepted a risk that RFI and its mitigation would exceed the 1.3-K error budget. Thus, RFI will likely remain a challenge afterwards due to its changing and uncertain nature. To address the challenge, we seek to answer the following questions: How does RFI evolve over the SMAP lifetime? What calibration error does the changing RFI environment cause? Can time series information be exploited to reduce these errors and improve calibration for all science products reliant upon SMAP radiometer data? In this talk, we address the first question.

Passive L-band radiometer↗

Spectrometric test of a linear array sensor

A spectroradiometer which measures spectral reflectivities and irradiance in discrete spectral channels was tested to determine the accuracy of its wavelength calibration. This sensor is a primary tool in the remote sensing investigations conducted on biomass at NASA's Goddard Space Flight Center. Measurements have been collected on crop and forest plants both in the laboratory and field with this radiometer to develop crop identification and plant stress remote sensing techniques. Wavelength calibration is essential for use in referencing the study measurements with those of other investigations and satellite remote sensor data sets. This calibration determines a wavelength vs channel address conversion which was found to have an RMS deviation of approximately half a channel, or 1.5 nm in the range from 360 to 1050 nm. A comparison of these results with those of another test showed an average difference of approximately 4 nm, sufficiently accurate for most investigative work.

Brown, Kenneth S.↗

In-orbit calibration adjustment of the Nimbus-7 SMMR

The procedure for converting raw antenna signals (counts) from the Nimbus-7 Scanning Multichannel Microwave Radiometer (SMMR) to microwave radiances is described. The procedure entails taking the raw data stored on TAT data tapes, applying an interim prelaunch calibration, correcting for polarization mixing, and finally adjusting the calibration so that the observations conform to model calculations of oceanic radiances. The results are stored on TCT data tapes with the same format as the TATs, i.e., the basic sampling interval of the SMMR is retained. The properties of the TCTs are compared with those of the other basic SMMR radiance data product, the CELL tapes, in which the integrated fields-of-view (IFOVs) have been averaged into cells with coarser sampling intervals and in which the prelaunch calibration is the final one used.

Gloersen, Per↗

Improved microwave radiometry for remote sensing

Significant improvements in the gain stability and overall performance of microwave radiometers have been achieved with the use of a self-balancing gain modulation technique. This technique, in combination with automatic thermal calibration, is particularly well suited for remote sensing radiometric applications. The essential features of such a radiometer, including typical data obtained from a spaceborne satellite, is presented to show the instrument's utility.

Leber, A.↗

Modeling and characterization of the Earth Radiation Budget Experiment (ERBE) nonscanner and scanner sensors

The Earth Radiation Budget Experiment (ERBE) is making high-absolute-accuracy measurements of the reflected solar and Earth-emitted radiation as well as the incoming solar radiation from three satellites: ERBS, NOAA-9, and NOAA-10. Each satellite has four Earth-looking nonscanning radiometers and three scanning radiometers. A fifth nonscanner, the solar monitor, measures the incoming solar radiation. The development of the ERBE sensor characterization procedures are described using the calibration data for each of the Earth-looking nonscanners and scanners. Sensor models for the ERBE radiometers are developed including the radiative exchange, conductive heat flow, and electronics processing for transient and steady state conditions. The steady state models are used to interpret the sensor outputs, resulting in the data reduction algorithms for the ERBE instruments. Both ground calibration and flight calibration procedures are treated and analyzed. The ground and flight calibration coefficients for the data reduction algorithms are presented.

Halyo, Nesim↗

Additional Characterization of Sonoran Pics in Support of A Stable Multi-Sensor Geostationary Imager Record

The Sonoran Desert is the most utilized Pseudo Invariant Calibration Site (PICS) located in the Americas for post-launch radiometer drift monitoring and sensor pair radiometric scaling. The Sonoran Desert is located near the US Arizona and Mexican border with an elevation of 37 m. The site has small spatial and angular variations; however, soil moisture can cause short- term periodic reflectance fluctuations. The NASA Clouds and the Earth’s Radiant Energy System (CERES) project utilizes the site to validate the GOES East and West imager calibration coefficients derived from inter-calibrating GOES with MODIS. Because the daily local noon angular solar and viewing angles repeat every year over the site, a daily exoatmospheric radiance model (DERM) can be constructed over the lifetime of a well-calibrated GOES sensor. DERM based on a well-calibrated GOES imager can then be used to determine the calibration coefficients of successive GOES imagers to provide a stable multi-sensor GOES imager record. This will ensure that the GOES retrieved clouds and derived broadband fluxes can be used to infer the regional diurnal cycle in between Terra and Aqua CERES measurements to accurately compute the daily mean regional fluxes and clouds over the 20-year CERES SYN1deg product. Although the Sonoran Desert surface reflectance and atmospheric column vary seasonally, the inter-annual variability of the seasonal cycle is small, but it adds noise to the resulting DERM calibration coefficients. We seek to reduce the uncertainty of the DERM approach by improving the clear-sky filtering and correlating the observed interannual reflectance variability with atmospheric parameters, such as precipitable water, ozone concentration, and aerosol optical depth. The additional characterization of the Sonoran Desert site DERM for both the GOES East and West positions should improve the accuracy of the CERES SYN1deg product clouds and fluxes.

Prathana Khakurel↗

Transmittance Measurement of a Heliostat Facility used in the Preflight Radiometric Calibration of Earth-Observing Sensors

Ball Aerospace and Technologies Corporation in Boulder, Colorado, has developed a heliostat facility that will be used to determine the preflight radiometric calibration of Earth-observing sensors that operate in the solar-reflective regime. While automatically tracking the Sun, the heliostat directs the solar beam inside a thermal vacuum chamber, where the sensor under test resides. The main advantage to using the Sun as the illumination source for preflight radiometric calibration is because it will also be the source of illumination when the sensor is in flight. This minimizes errors in the pre- and post-launch calibration due to spectral mismatches. It also allows the instrument under test to operate at irradiance values similar to those on orbit. The Remote Sensing Group at the University of Arizona measured the transmittance of the heliostat facility using three methods, the first of which is a relative measurement made using a hyperspectral portable spectroradiometer and well-calibrated reference panel. The second method is also a relative measurement, and uses a 12-channel automated solar radiometer. The final method is an absolute measurement using a hyperspectral spectroradiometer and reference panel combination, where the spectroradiometer is calibrated on site using a solar-radiation-based calibration.

Czapla-Myers, J.↗