Some studies on a solid-state sulfur probe for coal gasification systems

As a part of a program for the development of a sulfur probe for monitoring the sulfur potential in coal gasification reactors, an investigation was conducted regarding the efficiency of the solid electrolyte cell Ar+H2+H2S/CaS+CaF2+(Pt)//CaF2//Pt)+CaF2+CaS/H2S+H2+Ar. A demonstration is provided of the theory, design, and operation of a solid-state sulfur probe based on CaF2 electrolyte. It was found that the cell responds to changes in sulfur potential in a manner predicted by the Nernst equation. The response time of the cell at 1225 K, after a small change in temperature or gas composition, was 2.5 Hr, while at a lower temperature of 990 K the response time was approximately 9 hr. The cell emf was insensitive to a moderate increase in the flow rate of the test gas and/or the reference gas. The exact factors affecting the slow response time of galvanic cells based on a CaF2 electrolyte have not yet been determined. The rate-limiting steps may be either the kinetics of electrode reactions or the rate of transport through the electrolyte.

Jacob, K. T.↗

Magneto mitochondrial dysfunction mediated cancer cell death using intracellular magnetic nano-transducers

Mitochondria are crucial regulators of the intrinsic pathway of cancer cell death. The high sensitivity of cancer cells to mitochondrial dysfunction offers opportunities for emerging targets in cancer therapy. Herein, magnetic nano-transducers, which convert external magnetic fields into physical stress, are designed to induce mitochondrial dysfunction to remotely kill cancer cells. Spindle-shaped iron oxide nanoparticles were synthesized to maximize cellular internalization and magnetic transduction. The magneto-mechanical transduction of nano-transducers in mitochondria enhances cancer cell apoptosis by promoting a mitochondrial quality control mechanism, referred to as mitophagy. Furthermore, in the liver cancer animal model, nano-transducers are infused into the local liver tumor via the hepatic artery. After treatment with a magnetic field, in vivo mitophagy-mediated cancer cell death was also confirmed by mitophagy markers, mitochondrial DNA damage assay, and TUNEL staining of tissues. This study is expected to contribute to the development of nanoparticle-mediated mitochondria-targeting cancer therapy and biological tools, such as magneto-genetics.

60 APPLIED LIFE SCIENCES↗

A highly efficient light-trapping structure for thin-film silicon solar cells

A highly efficient light-trapping structure, consisting of a diffractive grating, a distributed Bragg reflector (DBR) and a metal reflector was proposed. As an example, the proposed light-trapping structure with an indium tin oxide (ITO) diffraction grating, an a-Si:H/ITO DBR and an Ag reflector was optimized by the simulation via rigorous coupled-wave analysis (RCWA) for a 2.0-{mu}m-thick c-Si solar cell with an optimized ITO front antireflection (AR) layer under the air mass 1.5 (AM1.5) solar illumination. The weighted absorptance under the AM1.5 solar spectrum (A{sub AM1.5}) of the solar cell can reach to 69%, if the DBR is composed of 4 pairs of a-Si:H/ITOs. If the number of a-Si:H/ITO pairs is up to 8, a larger A{sub AM1.5} of 72% can be obtained. In contrast, if the Ag reflector is not adopted, the combination of the optimized ITO diffraction grating and the 8-pair a-Si:H/ITO DBR can only result in an A{sub AM1.5} of 68%. As the reference, A{sub AM1.5} = 31% for the solar cell only with the optimized ITO front AR layer. So, the proposed structure can make the sunlight highly trapped in the solar cell. The adoption of the metal reflector is helpful to obtain highly efficient light-trapping effect with less number of DBR pairs, which makes that such light-trapping structure can be fabricated easily. (author)

14 SOLAR ENERGY↗

Atomic-scale Imaging of PGM-free Catalyst Active Sites by 30 keV 4D-STEM

Platinum group metal (PGM)-free catalysts have attracted a large amount of attention due to their potential for enabling low-cost, commercially viable hydrogen fuel cells and electrolyzers [1]. Degradation of cell performance remains a significant challenge, however, currently limiting implementation of devices that utilize PGM-free materials [2]. Controlling degradation in these materials requires a better understanding of the atomic structure of active sites, thought to be FeN4 structures within a graphitic carbon lattice, which would enable more accurate prediction of the associated degradation pathways. The exact structural arrangement of active sites in these materials is still debated since a range of structures have been computationally predicted and methods to directly validate these models are still needed [1,3-5].While scanning transmission electron microscopy (STEM) has provided initial glimpses into the nature of the proposed active sites, detailed evaluation of the structure of these sites is challenging since they involve defects, edges, and nitrogen dopants in the graphitic lattice, which are susceptible to beam damage [6,7]. Conventional STEM imaging and spectroscopy methods exacerbate this problem with dose-inefficiency or nonideal contrast characteristics for imaging light and heavy elements simultaneously. A method that minimizes damage while generating dose-efficient, easily-interpretable contrast for both light and heavy elements is therefore needed to facilitate imaging of sensitive active site atomic structure.Here, we demonstrate direct atomic-scale imaging of PGM-free catalyst active sites by low-voltage four-dimensional (4D)-STEM. To accomplish this, we pair a 30 keV aberration-corrected probe, which minimizes knock-on damage, with a fast pixelated detector that has optimal performance at low beam energies [8]. We show how this setup enables relatively simple center-of-mass (CoM) techniques [9,10] to produce images with an increased signal-to-noise ratio (SNR) and light-element contrast over conventional imaging modes, allowing the entire active site structure to be imaged at the atomic scale. Moreover, we show how electron ptychography [11,12] enables images with further improved characteristics to be obtained, for example by minimizing residual aberrations, which provides a more accurate structural representation. The increased understanding that these low-voltage 4D-STEM techniques will provide about the atomic structure of PGM-free active sites and their associated degradation pathways will facilitate rational design of next-generation materials, promoting development of low-cost hydrogen fuel cells, electrolyzers, and other energy conversion devices [13]. References:[1] U Martinez et al., Adv. Mater. 31 (2019), p. 1806545.[2] Y Shao et al., Adv. Mater. 31 (2019), p. 1807615.[3] J Kneebone et al., J. Phys. Chem. C 121, (2017), p.16283.[4] T Mineva et al., ACS Catal. 9 (2019), p. 9359.[5] J Li et al., Nat. Catal. 4 (2021), p. 10.[6] T Susi et al., ACS Nano 6 (2012), p. 8837.[7] P Zelenay and DJ Myers, US Department of Energy Hydrogen and Fuel Cells Program 2017 Annual Merit Review and Peer Evaluation Meeting, Washington, DC (2017).[8] H Ryll et al., J. Inst. 11 (2016), p. P04006.[9] K Müller et al., Nat. Commun. 5 (2014), p. 5653.[10] I Lazic et al., Ultramicroscopy 160 (2016), p. 265.[11] H Yang et al., Nat. Commun. 7 (2016), p. 12532.[12] Y Jiang et al., Nature 559 (2018), p. 343. [13] Research sponsored by the Hydrogen and Fuel Cell Technologies Office, Office of Energy Efficiency and Renewable Energy, US Department of Energy (DOE). Research was conducted at the Center for Nanophase Materials Sciences, which is a DOE Office of Science User Facility.

Zachman, Michael↗

Hydrogenated indium oxide window layers for high-efficiency Cu(In,Ga)Se{sub 2} solar cells

High mobility hydrogenated indium oxide is investigated as a transparent contact for thin film Cu(In,Ga)Se{sub 2} (CIGS) solar cells. Hydrogen doping of In{sub 2}O{sub 3} thin films is achieved by injection of H{sub 2}O water vapor or H{sub 2} gas during the sputter process. As-deposited amorphous In{sub 2}O{sub 3}:H films exhibit a high electron mobility of ∼50 cm{sup 2}/Vs at room temperature. A bulk hydrogen concentration of ∼4 at. % was measured for both optimized H{sub 2}O and H{sub 2}-processed films, although the H{sub 2}O-derived film exhibits a doping gradient as detected by elastic recoil detection analysis. Amorphous IOH films are implemented as front contacts in CIGS based solar cells, and their performance is compared with the reference ZnO:Al electrodes. The most significant feature of IOH containing devices is an enhanced open circuit voltage (V{sub OC}) of ∼20 mV regardless of the doping approach, whereas the short circuit current and fill factor remain the same for the H{sub 2}O case or slightly decrease for H{sub 2}. The overall power conversion efficiency is improved from 15.7% to 16.2% by substituting ZnO:Al with IOH (H{sub 2}O) as front contacts. Finally, stability tests of non-encapsulated solar cells in dry air at 80 °C and constant illumination for 500 h demonstrate a higher stability for IOH-containing devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Validation test of advanced technology for IPV nickel-hydrogen flight cells: Update

Individual pressure vessel (IPV) nickel-hydrogen technology was advanced at NASA Lewis and under Lewis contracts with the intention of improving cycle life and performance. One advancement was to use 26 percent potassium hydroxide (KOH) electrolyte to improve cycle life. Another advancement was to modify the state-of-the-art cell design to eliminate identified failure modes. The modified design is referred to as the advanced design. A breakthrough in the low-earth-orbit (LEO) cycle life of IPV nickel-hydrogen cells has been previously reported. The cycle life of boiler plate cells containing 26 percent KOH electrolyte was about 40,000 LEO cycles compared to 3,500 cycles for cells containing 31 percent KOH. The boiler plate test results are in the process of being validated using flight hardware and real time LEO testing at the Naval Weapons Support Center (NWSC), Crane, Indiana under a NASA Lewis Contract. An advanced 125 Ah IPV nickel-hydrogen cell was designed. The primary function of the advanced cell is to store and deliver energy for long-term, LEO spacecraft missions. The new features of this design are: (1) use of 26 percent rather than 31 percent KOH electrolyte; (2) use of a patented catalyzed wall wick; (3) use of serrated-edge separators to facilitate gaseous oxygen and hydrogen flow within the cell, while still maintaining physical contact with the wall wick for electrolyte management; and (4) use of a floating rather than a fixed stack (state-of-the-art) to accommodate nickel electrode expansion due to charge/discharge cycling. The significant improvements resulting from these innovations are: extended cycle life; enhanced thermal, electrolyte, and oxygen management; and accommodation of nickel electrode expansion. The advanced cell design is in the process of being validated using real time LEO cycle life testing of NWSC, Crane, Indiana. An update of validation test results confirming this technology is presented.

Smithrick, John J.↗

Long-term insulin-like growth factor-I expression in skeletal muscles attenuates the enhanced in vitro proliferation ability of the resident satellite cells in transgenic mice

Insulin-like growth factor-I (IGF-I) overexpression for 1-month in mouse skeletal muscle increases satellite cell proliferation potential. However, it is unknown whether this beneficial enhancement by IGF-I expression would persist over a longer-term duration in aged mice. This is an important issue to address if a prolonged course of IGF-I is to be used clinically in muscle-wasting conditions where satellite cells may become limiting. Using the IGF-I transgenic (IGF-I Tg) mouse that selectively expresses the IGF-I transgene in striated muscles, we found that 18-months of continuous IGF-I overexpression led to a loss in the enhanced in vitro proliferative capacity of satellite cells from Tg skeletal muscles. Also 18-month-old IGF-I Tg satellite cells lost the enhanced BrdU incorporation, greater pRb and Akt phosphorylations, and decreased p27(Kip1) levels initially observed in cells from 1-month-old IGF-I Tg mice. The levels of those biochemical markers reverted to similar values seen in the 18-months WT littermates. These findings, therefore, suggest that there is no further beneficial effect on enhancing satellite cell proliferation ability with persistent long-term expression of IGF-I in skeletal muscles of these transgenic mice.

Non-NASA Center↗

Using Radial Basis Functions to Approximate Battery Differential Capacity and Differential Voltage

As part of the Department of Energy’s Applied Battery Research Program, lithium-ion cells of various sizes and chemistries are aged with periodic reference performance tests to ascertain degradation rates. The reference tests included a very slow discharge and charge based on a constant current equal to 1/25th of the rated capacity to elucidate the true electrochemical capacity of the cell. A differential analysis of these data helps to identify the individual kinetic and thermodynamic contributions of the anode and cathode. However, differential curves are very noisy, and previous smoothing methods included simple data reduction and moving averages. This paper introduces an alternative method of finding the differential voltage and differential capacity curves based on radial basis functions. The voltage profile is fit with a number of Gaussian curves, and the resulting model is differentiated. This approach also has the added advantage of assessing model uncertainty based on a bootstrap analysis. The radial basis function method was successfully applied to various lithium-ion chemistries tested under the Applied Battery Research Program. The resulting differential capacity and differential voltage curves were generally smoother than the corresponding curves found by previous methods and also showed little variance, indicating a good model fit. These results imply that the radial basis function technique is a more robust tool for assessing differential data.

25 ENERGY STORAGE↗

Fluorescent Quantum Dots for Biological Labeling

Fluorescent semiconductor quantum dots that can serve as "on/off" labels for bacteria and other living cells are undergoing development. The "on/off" characterization of these quantum dots refers to the fact that, when properly designed and manufactured, they do not fluoresce until and unless they come into contact with viable cells of biological species that one seeks to detect. In comparison with prior fluorescence-based means of detecting biological species, fluorescent quantum dots show promise for greater speed, less complexity, greater sensitivity, and greater selectivity for species of interest. There are numerous potential applications in medicine, environmental monitoring, and detection of bioterrorism.

McDonald, Gene↗

Detection of an internal short circuit in a battery

An electrical device comprises a battery cell; a pressure sensor for measuring swelling forces of the battery cell, optionally with voltage, temperature and current sensors, and a battery management system including a controller. The controller executes a program to: (i) determine a reference swelling force corresponding to a reference electrical signal received from the pressure sensor at an earlier reference time, (ii) determine a second swelling force corresponding to a second electrical signal received from the pressure sensor at a later second time, and (iii) determine whether a risk of internal short circuit of the battery cell exists by comparing a reference level of the reference electrical signal and a signal representative of the second electrical signal. When the signal representative of the second electrical signal exceeds the reference level of the reference electrical signal by a threshold amount, a risk of internal short circuit of the cell exists.

Stefanopoulou, Anna G.↗

Wave propagation speeds and source term influences in single and integral porosity shallow water equations

In urban flood modeling, so-called porosity shallow water equations (PSWEs), which conceptually account for unresolved structures, e.g., buildings, are a promising approach to addressing high CPU times associated with state-of-the-art explicit numerical methods. The PSWE can be formulated with a single porosity term, referred to as the single porosity shallow water model (SP model), which accounts for both the reduced storage in the cell and the reduced conveyance, or with two porosity terms: one accounting for the reduced storage in the cell and another accounting for the reduced conveyance. The latter form is referred to as an integral or anisotropic porosity shallow water model (AP model). The aim of this study was to analyze the differences in wave propagation speeds of the SP model and the AP model and the implications of numerical model results. First, augmented Roe-type solutions were used to assess the influence of the source terms appearing in both models. It is shown that different source terms have different influences on the stability of the models. Second, four computational test cases were presented and the numerical models were compared. It is observed in the eigenvalue-based analysis as well as in the computational test cases that the models converge if the conveyance porosity in the AP model is close to the storage porosity. If the porosity values differ significantly, the AP model yields different wave propagation speeds and numerical fluxes from those of the BP model. In this study, the ratio between the conveyance and storage porosities was determined to be the most significant parameter.

58 GEOSCIENCES↗

Multi-plane moment-of-fluid interface reconstruction in 3D

Moment-of-fluid (MOF) methods for interface reconstruction approximate the region occupied by material in each mesh element only through reference to its geometric moments. Here, we present a 3D MOF method that represents the material (POM) in each cell as the convex intersection of the cell and multiple half-spaces, each selected to minimize the least-squares error between computed moments of the approximated material and provided reference moments. This optimization problem is highly non-linear and non-convex, making the numerical result very sensitive to the initial guess. To create an effective initial guess in each cell, we construct an ellipsoid from 0th–2nd order reference moments such that its shape corresponds with that of the POM. Within this ellipsoid we inscribe a polyhedron, and initialize the minimization problem with the half-spaces defined by each of its faces. The inscribed polyhedron has minimally 4 faces, and using up to 3rd order moments permits optimization over up to 20 unknown values. We therefore define MOF methods that utilize 4, 5, or 6 half-spaces, correspondingly initialized with the faces of a single inscribed tetrahedron, triangular prism, or hexahedron. Stability of the non-linear optimization is further improved with a prepossessing step that normalizes the reference moments according to the axes of the reference ellipsoid. Using this approach, the non-linear least-squares solver reliably converges to a near-global minimum from a single initial guess. We demonstrate accuracy and robustness using single-cell and multi-cell examples over a wide spectrum of geometry. In particular, we demonstrate our ability to exactly reproduce several important and complex features defined by up to four half-spaces, such as corners, filaments, filament tips, and embedded material in the cell.

3D interface reconstruction↗

Comparison of homogenized and enhanced diffusion solutions of model PWR problems

Model problem comparisons in slab geometry are made between two forms of homogenized diffusion theory and enhanced diffusion theory. The pin-cell discontinuity factors for homogenized diffusion calculations are derived from homogenized variational nodal P1 response matrices and from standard finite differencing. Enhanced diffusion theory consists of applying quasi-reflected interface conditions to reduce variational nodal Pn response matrices to one degree of freedom per interface, without homogenization within the cell. As expected both homogenized diffusion methods preserve reaction rates exactly if the discontinuity factors are derived from the P 11 reference solutions. If no reference lattice solution is available, discontinuity factors may be approximated from single cells with reflected boundary conditions; the computational effort is then comparable to calculating the enhanced diffusion response matrices. In this situation enhanced diffusion theory gives the most accurate results and finite difference discontinuity factors the least accurate. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Understanding the limits of Li-NMC811 half-cells

As we push the boundaries of state-of-the-art lithium-ion intercalation materials, such as nickel-rich chemistries, the ability to isolate and understand specific degradation and performance limitations is becoming increasingly important. Half-cells, wherein lithium metal is employed as a dual counter and reference electrode, are commonly used in industry and academia for this purpose. However, the high reactivity of lithium metal drives premature electrolyte degradation and limits cell lifetime, bringing into question the reliability and validity of this cell configuration. Here we explore the limitations of half-cell studies of LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811) electrodes with commercially relevant loading. We identify the failure mechanism of this cell configuration through a combination of electrochemical, chemical, and spectroscopic techniques and show that the Li has a direct detrimental impact on the NMC811 chemistry. Our measurements show that vinylene carbonate is critical for these half-cell studies and underpins the cycle limits. Furthermore, we demonstrate the use of Li 4 Ti 5 O 12 (LTO) as an alternative counter electrode for understanding the performance of NMC positive electrode materials, due to its high coulombic efficiency and low reactivity with the organic carbonates routinely employed in lithium-ion battery cell chemistries. These data confirm that NMC811 electrodes can tolerate high voltages (stressed) conditions and that cell failure is mainly a result of crossover effects.

25 ENERGY STORAGE↗

Production of Seamless Superconducting Radio Frequency Cavities from Ultra-fine Grained Niobium, Phase II Final Report

The positron and electron linacs of the International Linear Collider (ILC) will require over 14,000, nine-cell, one meter length, superconducting radio frequency (SRF) cavities [ILC Reference Design Report, 2007]. Manufacturing on this scale will benefit from more efficient fabrication methods. The current methods of fabricating SRF cavities involve deep drawing of the halves of each of the elliptical cells and joining them by high-vacuum, electron beam welding, with at least 19 circumferential welds per cavity. The welding is costly and has undesirable effects on the cavity surfaces, including grain-scale surface roughening at the weld seams. Hydroforming of seamless tubes avoids welding, but hydroforming of coarse-grained seamless tubes results in strain-induced surface roughening. Surface roughness limits accelerating fields, because asperities prematurely exceed the critical magnetic field and become normal conducting. This project explored the technical and economic feasibility of an improved processing method for seamless tubes for hydroforming. Severe deformation of bulk material was first used to produce a fine structure, followed by extrusion and flow-forming methods of tube making. Extrusion of the randomly oriented, fine-grained bulk material proceeded under largely steady-state conditions, and resulted in a uniform structure, which was found to be finer and more crystallographically random than standard (high purity) RRR niobium sheet metal. A 165 mm diameter billet of RRR grade niobium was processed into five, 150 mm I.D. tubes, each over 1.8 m in length, to meet the dimensions used by the DESY ILC hydroforming machine. Mechanical properties met specifications. Costs of prototype tube production were approximately twice the price of RRR niobium sheet, and are expected to be comparable with economies of scale. Hydroforming and superconducting testing will be pursued in subsequent collaborations with DESY and Fermilab. SRF Cavities are used to construct particle accelerators for high-energy physics research, as well as for lower energy particle accelerators, and Free Electron Lasers. These machines have applications in the fields of basic science, industrial processing, medical diagnostics, pharmaceutical research and weapons systems. The scientific community and the general public will benefit from the implementation of this technology since lower production costs will increase the availability of SRF particle accelerators.

36 MATERIALS SCIENCE↗

Recent developments and applications with gas cell correlation spectrometer

Gaspec, a gas filter correlation spectrometer, is described. Gaspec is a dual-gas three-channel instrument using two detectors which receive amplitude-shared source signals modulated at the frequency of the chopper. Several units for operation around the 3-5 micron and the 8-15 micron region have been constructed, and gases such as CO2, CO, CH4, HCl, NO, and hydrazines can be detected. Advantages of Gaspec are considered with reference to improvements developed for the basic Cospec (gas cell correlation spectrometer) instrument.

Barringer, A. R.↗

On the use of a charged tunnel layer as a hole collector to improve the efficiency of amorphous silicon thin-film solar cells

A new concept, using a negatively charged tunnel layer as a hole collector, is proposed and theoretically investigated for application in amorphous silicon thin-film solar cells. The concept features a glass/transparent conductive oxide/ultra-thin negatively charged tunnel layer/intrinsic a-Si:H/n-doped a-Si:H/metal structure. The key feature of this so called t{sup +}-i-n structure is the introduction of a negatively charged tunnel layer (attracting holes from the intrinsic absorber layer), which substitutes the highly recombination active p-doped a-Si:H layer in a conventional p-i-n configuration. Atomic layer deposited aluminum oxide (ALD AlO{sub x}) is suggested as a potential candidate for such a tunnel layer. Using typical ALD AlO{sub x} parameters, a 27% relative efficiency increase (i.e., from 9.7% to 12.3%) is predicted theoretically for a single-junction a-Si:H solar cell on a textured superstrate. This prediction is based on parameters that reproduce the experimentally obtained external quantum efficiency and current-voltage characteristics of a conventional processed p-i-n a-Si:H solar cell, reaching 9.7% efficiency and serving as a reference. Subsequently, the p-doped a-Si:H layer is replaced by the tunnel layer (studied by means of numerical device simulation). Using a t{sup +}-i-n configuration instead of a conventional p-i-n configuration will not only increase the short-circuit current density (from 14.4 to 14.9 mA/cm{sup 2}, according to our simulations), it also enhances the open-circuit voltage and the fill factor (from 917 mV to 1.0 V and from 74% to 83%, respectively). For this concept to work efficiently, a high work function front electrode material or a high interface charge is needed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precautions of Using Three-Electrode Configuration to Measure Electrode Overpotential in Solid Oxide Electrochemical Cells: Insights from Finite Element Modeling

Accurate determination of electrode overpotentials is essential to assess the performance of the electrode and understand the rate-limiting steps involved. Three-electrode configuration with the use of a reference electrode at a fixed potential is a standard way to measure overpotential of a specific electrode in liquid electrochemical systems. However, application of such three-electrode configuration to solid electrochemical cells for overpotential determination is not straightforward and requires extra caution. Here we report a theoretical Finite Element Analysis on the geometrical requirements for which the reference electrode can be applied to anode- or electrolyte-supported solid oxide button cells. The modeling results suggest that the symmetry of the working and counter electrodes is the key factor determining if a reference electrode is suitable to use. For anode-supported fuel cells with asymmetrical working and counter electrodes, reference electrode cannot be used under all circumstances. To use reference electrode for overpotential measurements, electrolyte-supported cells with symmetrical semicircular-shaped electrodes are preferred. A data processing procedure has also been presented to obtain the electrode overpotential from the measured potential using the three-electrode scheme in solid oxide electrochemical cells.

25 ENERGY STORAGE↗