Search NASA⌕ Search

SEARCH · Search NASA

Results for “response surface methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Measurement of gold nanofilm dose enhancement using unlaminated radiochromic film

Purpose: Bombarding high-Z material with x-ray radiation releases Auger electrons and Coster–Kronig electrons, along with deeper penetrating fluorescent x-rays and photoelectrons. The Auger and Coster–Kronig electron penetration distance is on the order of nanometers to micrometers in water or tissue, creating a large dose enhancement accompanied by a RBE greater than 1 at the cellular level. The authors’ aim is to measure the gold nanofilm dose enhancement factor (DEF) at the cellular level with unlaminated radiochromic film via primary 50 kVp tungsten x-ray spectrum interaction, similar to an electronic brachytherapy spectrum. Methods: Unlaminated Gafchromic{sup ®} EBT2 film and Monte Carlo modeling were combined to derive DEF models. Gold film of thickness 23.1 ± 4.3 nm and surface roughness of 1.2 ± 0.2 nm was placed in contact with unlaminated radiochromic film in a downstream orientation and exposed to a 50 kVp tungsten bremsstrahlung, mean energy 19.2 keV. Film response correction factors were derived by Monte Carlo modeling of electron energy deposition in the film’s active layer, and by measuring film energy dependence from 4.5 keV to 50 kVp. Results: The measured DEF within a 13.6 μm thick water layer was 0.29 with a mean dose of 94 ± 9.4 cGy from Au emissions and 324 ± 32.4 cGy from the 50 kVp primary beam. Monte Carlo derived correction factors allowed determination of Au contributed dose in shallower depths at 0.25 μm intervals. Maximum DEF of 18.31 was found in the first 0.25 μm water depth. Conclusions: Dose enhancement from Au nanofilm can be measured at the cellular level using unlaminated radiochromic film. Complementing the measured dose value with Monte Carlo calculations allows estimation of dose enhancement at depth increments within the cellular range.

60 APPLIED LIFE SCIENCES↗

Selected-control hydrothermal synthesis and formation mechanism of 1D ammonium vanadate

Selective-controlled structure and shape of ammonium vanadate nanocrystals were successfully synthesized by a simple hydrothermal method without the presence of catalysts or templates. It was found that tuning the pH of the growth solution was a crucial step for the control of the phase-compositional, structure and morphology transformation. The final products were NH{sub 4}V{sub 4}O{sub 10} nanobelts, (NH{sub 4}){sub 2}V{sub 6}O{sub 16}.1.5H{sub 2}O nanowires, and (NH{sub 4}){sub 6}V{sub 10}O{sub 28}.6H{sub 2}O nanobundles, respectively, when the pH of the growth solution varied from 2.5 to 1.5, then to 0.5. The hydrogen bonding interaction and the surface free energies were responsible for the formation of the ammonium vanadates with the different structure and morphology. The conductivity measurements showed the one-dimensional (1D) ammonium vanadates were semiconductors at room temperature. The conductivity of 1D ammonium vanadates varied from 1.95x10{sup -4} to 2.45x10{sup -3} S cm{sup -1} due to the different structures. - Graphical abstract: Selective-controlled structure and shape of ammonium vanadate nanocrystals were successfully synthesized by a simple hydrothermal method without the presence of catalysts or templates. The final products were NH{sub 4}V{sub 4}O{sub 10} nanobelts, (NH{sub 4}){sub 2}V{sub 6}O{sub 16}.1.5H{sub 2}O nanowires, and (NH{sub 4}){sub 6}V{sub 10}O{sub 28}.6H{sub 2}O nanobundles, respectively, when the pH of the growth solution varied from 2.5 to 1.5, then to 0.5.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new method for wideband characterization of resonator-based sensing platforms

A new approach to the electronic instrumentation for extracting data from resonator-based sensing devices (e.g., microelectromechanical, piezoelectric, electrochemical, and acoustic) is suggested and demonstrated here. Traditionally, oscillator-based circuitry is employed to monitor shift in the resonance frequency of the resonator. These circuits give a single point measurement at the frequency where the oscillation criterion is met. However, the resonator response itself is broadband and contains much more information than a single point measurement. Here, we present a method for the broadband characterization of a resonator using white noise as an excitation signal. The resonator is used in a two-port filter configuration, and the resonator output is subjected to frequency spectrum analysis. The result is a wideband spectral map analogous to the magnitude of the S21 parameters of a conventional filter. Compared to other sources for broadband excitation (e.g., frequency chirp, multisine, or narrow time domain pulse), the white noise source requires no design of the input signal and is readily available for very wide bandwidths (1 MHz-3 GHz). Moreover, it offers simplicity in circuit design as it does not require precise impedance matching; whereas such requirements are very strict for oscillator-based circuit systems, and can be difficult to fulfill. This results in a measurement system that does not require calibration, which is a significant advantage over oscillator circuits. Simulation results are first presented for verification of the proposed system, followed by measurement results with a prototype implementation. A 434 MHz surface acoustic wave (SAW) resonator and a 5 MHz quartz crystal microbalance (QCM) are measured using the proposed method, and the results are compared to measurements taken by a conventional bench-top network analyzer. Maximum relative differences in the measured resonance frequencies of the SAW and QCM resonators are 0.0004% and 0.002%, respectively. The ability to track a changing sensor response is demonstrated by inducing temperature variations and measuring resonance frequency simultaneously using the proposed technique in parallel with a network analyzer. The relative difference between the two measurements is about 5.53 ppm, highlighting the impressive accuracy of the proposed system. Using commercially available digital signal processors (DSPs), we believe that this technique can be implemented as a system-on-a-chip solution resulting in a very low cost, easy to use, portable, and customizable sensing system. In addition, given the simplicity of the signal and circuit design, and its immunity to other common interface concerns (injection locking, oscillator interference, and drift, etc.), this method is better suited to accommodating array-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Morphology, microstructure, and doping behaviour: A comparison between different deposition methods for poly-Si/SiO x passivating contacts

In this work, we study how crystallographic structures, optoelectronic properties, and nanoscale surface morphologies of ex situ phosphorus-doped polycrystalline silicon (poly-Si)/SiO x passivating contacts, formed by different deposition methods (sputtering, plasma-enhanced chemical vapour deposition [PECVD], and low-pressure chemical vapour deposition [LPCVD]), are investigated and compared. Across all these deposition technologies, we noted the same trend: higher diffusion temperatures yield films that are more crystalline but that have rougher surface morphologies due to bigger surface crystal grains. Also, the recrystallization process of the as-deposited Si films starts from the SiO x interface, rather than from the film surface and bulk. However, there are some distinct differences among these technologies. First, the LPCVD method yields the lowest deposition rate, roughest surfaces, and smallest degree of crystallinity on finished poly-Si films. In contrast, the PECVD method has the highest deposition rate and smoothest surfaces for both as-deposited Si and annealed poly-Si films. Second, as-deposited sputtered and PECVD Si films contain only an amorphous phase, whereas as-deposited LPCVD films already has some crystalline phase. Third, the LPCVD phosphorus in-diffusion into the substrate depends strongly on the initial film thickness, whereas for the other two methods, it is weakly dependent on thickness. Finally, the passivation quality of every poly-Si film type has different responses to the film thickness and diffusion temperature, suggesting that the ex situ doping optimization should be performed independently.

14 SOLAR ENERGY↗

Diffusion of Cd and Te adatoms on CdTe(111) surfaces: A computational study using density functional theory

CdTe is one of the most promising semiconductor for thin-film based solar cells. Here we report a computational study of Cd and Te adatom diffusion on the CdTe (111) A-type (Cd terminated) and B-type (Te terminated) surfaces and their migration paths. The atomic and electronic structure calculations are performed under the DFT formalism and climbing Nudge Elastic Band (cNEB) method has been applied to evaluate the potential barrier of the Te and Cd diffusion. In general the minimum energy site on the surface is labeled as A{sub a} site. In case of Te and Cd on B-type surface, the sub-surface site (a site just below the top surface) is very close in energy to the A site. This is responsible for the subsurface accumulation of adatoms and therefore, expected to influence the defect formation during growth. The diffusion process of adatoms is considered from A{sub a} (occupied) to A{sub a} (empty) site at the nearest distance. We have explored three possible migration paths for the adatom diffusion. The adatom surface interaction is highly dependent on the type of the surface. Typically, Te interaction with both type (5.2 eV for A-type and 3.8 eV for B-type) is stronger than Cd interactions(2.4 eV for B-type and 0.39 eV for A-type). Cd interaction with the A-type surface is very weak. The distinct behavior of the A-type and B-type surfaces perceived in our study explain the need of maintaining the A-type surface during growth for smooth and stoichiometric growth.

36 MATERIALS SCIENCE↗

Laser Ablation-Aerosol Mass Spectrometry-Chemical Ionization Mass Spectrometry for Ambient Surface Imaging

Mass spectrometry imaging is becoming an increasingly common analytical technique due to its ability to provide spatially resolved chemical information. In this paper, we report a novel imaging approach combining laser ablation with two mass spectrometric techniques, aerosol mass spectrometry and chemical ionization mass spectrometry, separately and in parallel. Both mass spectrometric methods provide the fast response, rapid data acquisition, low detection limits, and high-resolution peak separation desirable for imaging complex samples. Additionally, the two techniques provide complementary information with aerosol mass spectrometry providing near universal detection of all aerosol molecules and chemical ionization mass spectrometry with a heated inlet providing molecular-level detail of both gases and aerosols. The two techniques operate with atmospheric pressure interfaces and require no matrix addition for ionization, allowing for samples to be investigated in their native state under ambient pressure conditions. We demonstrate the ability of laser ablation-aerosol mass spectrometry-chemical ionization mass spectrometry (LA-AMS-CIMS) to create 2D images of both standard compounds and complex mixtures. Finally, the results suggest that LA-AMS-CIMS, particularly when combined with advanced data analysis methods, could have broad applications in mass spectrometry imaging applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Process design tools and techno-economic analysis for capacitive deionization

Capacitive deionization (CDI) devices use cyclical electrosorption on porous electrode surfaces to achieve water desalination. Process modeling and design of CDI systems requires accurate treatment of the coupling among input electrical forcing, input flow rates, and system responses including salt removal dynamics, water recovery, energy storage, and dissipation. Techno-economic analyses of CDI further require a method to calculate and compare between a produced commodity (e.g. desalted water) versus capital and operational costs of the system. In this work, we demonstrate a new modeling and analysis tool for CDI developed as an installable Matlab program that allows direct numerical simulation of CDI dynamics and calculation of key performance and cost parameters. The program is provided for free and is used to run open-source Simulink models. The Simulink environment sends information to the program and allows for a drag and drop design space where users can connect CDI cells to relevant periphery blocks such as grid energy, battery, solar panel, waste disposal, and maintenance/labor cost streams. The program allows for simulation of arbitrary current forcing and arbitrary flow rate forcing of one or more CDI cells. We employ validated well-mixed reactor formulations together with a non-linear circuit model formulation that can accommodate a variety of electric double layer sub-models (e.g. for charge efficiency). The program includes a graphical user interface (GUI) to specify CDI plant parameters, specify operating conditions, run individual tests or parameter batch-mode simulations, and plot relevant results. The techno-economic models convert among dimensional streams of species (e.g. feed, desalted water, and brine), energy, and cost and enable a variety of economic estimates including levelized water costs.

42 ENGINEERING↗

Statistically elucidated responses from low-signal contrast mechanisms in ultrafast electron microscopy

The emergence of ultrafast electron microscopy (UEM) has enabled the discovery of strongly correlated dynamic mechanisms, including electron–phonon coupling, structural phase transitions, thermal transport, and electromagnetic deflection. Most UEM systems operate stroboscopically, meaning that the technique is susceptible to artifacts, mistakes, and misinterpretation of the data due to extensive experimental effort. In contrast to the ultrafast designation, data acquisition is extraordinarily slow because the electron beam has significantly reduced signal compared to traditional transmission electron microscopy due to pulsing the electron beam. Consequently, the sample may drift, tilt, or undergo irreversible structural changes that are independent of the time-resolved dynamics throughout the experimental time frame. Furthermore, these datasets require significant user interpretation that can be problematic when proper controls are not implemented thoroughly. Here, we demonstrate a new algorithm designed to separate ultrafast structural dynamics from long-term artifacts using a LiNbO 3 sample experiencing electrically driven surface acoustic wave propagation. Additionally, we provide examples of the impact of user bias when analyzing the data and provide a methodology, which enables the extraction of time-resolved responses when the image signal is extraordinarily low. Overall, the goal of this publication is to provide methods that validate the experimental results and reduce researcher biases during UEM data interpretation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

FY08 LDRD Final Report Stem Cell Fate Decisions

A detailed understanding of the biological control of fate decisions of stem and progenitor cells is needed to harness their full power for tissue repair and/or regeneration. Currently, internal and external factors that regulate stem cell fate are not fully understood. We aim to engineer biocompatible tools to facilitate the measurement and comparison of the roles and significance of immobilized factors such as extracellular matrix and signaling peptides, synergistic and opposing soluble factors and signals, and cell-to-cell communication, in stem cell fate decisions. Our approach is based on the development of cell microarrays to capture viable stem/progenitor cells individually or in small clusters onto substrate-bound signals (e.g. proteins), combined with conventional antibody and customized subcellular markers made in-house, to facilitate tracking of cell behavior during exposure to relevant signals. Below we describe our efforts, including methods to manipulate a model epithelial stem cell system using a custom subcellular reporter to track and measure cell signaling, arrays with surface chemistry that support viable cells and enable controlled presentation of immobilized signals to cells on the array and fluorescence-based measurement of cell response, and successful on-array tests via conventional immunofluorescence assays that indicate correct cell polarity, localization of junctional proteins, and phenotype, properties which are essential to measuring true cell responses.

59 BASIC BIOLOGICAL SCIENCES↗

Spatial and temporal variation of surface-enhanced Raman scattering at Ag nanowires in aqueous solution

We present surface enhanced Raman spectroscopy (SERS) and Raman imaging of small organic molecules at well-defined nanostructures formed by single silver nanowires (NWs). We show that SERS can be obtained at single, crossed, and bundled Ag NWs for mercaptopyridine, adenine, cytosine, guanine, and thymine. Crossed wires and parallel Ag NWs have SERS enhancement factors much higher than single Ag NWs. New additional junctions formed by a silver nanoparticle and a single Ag NW, and bundled NWs provide SERS intensity higher than a single Ag NW. The SERS signal of single Ag NWs can be further enhanced by decorating the Ag NW surface with gold nanoparticles using electroless deposition. Single Ag NW Raman imaging with a 10 ms time resolution when compared with photoluminescence (PL) imaging results reveal a different dynamic response of SERS and PL under steady state laser excitation. Dynamic photoluminescence blinking activities are suppressed in the presence of the surface coating of Raman active molecules (e.g., mercaptopyridine) and the SERS signal is quite stable in a wide field excitation configuration. The Discrete Dipole Approximation (DDA) method was used to calculate the local field intensity that can be applied to help understand the enhanced PL and SERS at the junction of Ag NWs

Environmental Molecular Sciences Laboratory↗

2017 GTO Project review Laboratory Evaluation of EGS Shear Stimulation.

The objectives and purpose of this research has been to produce laboratory-based experimental and numerical analyses to provide a physics-based understanding of shear stimulation phenomena (hydroshearing) and its evolution during stimulation. Water was flowed along fractures in hot and stressed fractured rock, to promote slip. The controlled laboratory experiments provide a high resolution/high quality data resource for evaluation of analysis methods developed by DOE to assess EGS “behavior” during this stimulation process. Segments of the experimental program will provide data sets for model input parameters, i.e., material properties, and other segments of the experimental program will represent small scale physical models of an EGS system, which may be modeled. The coupled lab/analysis project has been a study of the response of a fracture in hot, water-saturated fractured rock to shear stress experiencing fluid flow. Under this condition, the fracture experiences a combination of potential pore pressure changes and fracture surface cooling, resulting in slip along the fracture. The laboratory work provides a means to assess the role of “hydroshearing” on permeability enhancement in reservoir stimulation. Using the laboratory experiments and results to define boundary and input/output conditions of pore pressure, thermal stress, fracture shear deformation and fluid flow, and models were developed and simulations completed by the University of Oklahoma team. The analysis methods are ones used on field scale problems. The sophisticated numerical models developed contain parameters present in the field. The analysis results provide insight into the role of fracture slip on permeability enhancement-“hydroshear” is to be obtained. The work will provide valuable input data to evaluate stimulation models, thus helping design effective EGS.

58 GEOSCIENCES↗

SU-F-SPS-06: Implementation of a Back-Projection Algorithm for 2D in Vivo Dosimetry with An EPID System

Purpose: To implement a back-projection algorithm for 2D dose reconstructions for in vivo dosimetry in radiation therapy using an Electronic Portal Imaging Device (EPID) based on amorphous silicon. Methods: An EPID system was used to calculate dose-response function, pixel sensitivity map, exponential scatter kernels and beam hardenig correction for the back-projection algorithm. All measurements were done with a 6 MV beam. A 2D dose reconstruction for an irradiated water phantom (30×30×30 cm{sup 3}) was done to verify the algorithm implementation. Gamma index evaluation between the 2D reconstructed dose and the calculated with a treatment planning system (TPS) was done. Results: A linear fit was found for the dose-response function. The pixel sensitivity map has a radial symmetry and was calculated with a profile of the pixel sensitivity variation. The parameters for the scatter kernels were determined only for a 6 MV beam. The primary dose was estimated applying the scatter kernel within EPID and scatter kernel within the patient. The beam hardening coefficient is σBH= 3.788×10{sup −4} cm{sup 2} and the effective linear attenuation coefficient is µAC= 0.06084 cm{sup −1}. The 95% of points evaluated had γ values not longer than the unity, with gamma criteria of ΔD = 3% and Δd = 3 mm, and within the 50% isodose surface. Conclusion: The use of EPID systems proved to be a fast tool for in vivo dosimetry, but the implementation is more complex that the elaborated for pre-treatment dose verification, therefore, a simplest method must be investigated. The accuracy of this method should be improved modifying the algorithm in order to compare lower isodose curves.

60 APPLIED LIFE SCIENCES↗

Measurement of Mechanical Properties of Cantilever Shaped Materials

Microcantilevers were first introduced as imaging probes in Atomic Force Microscopy (AFM) due to their extremely high sensitivity in measuring surface forces. The versatility of these probes, however, allows the sensing and measurement of a host of mechanical properties of various materials. Sensor parameters such as resonance frequency, quality factor, amplitude of vibration and bending due to a differential stress can all be simultaneously determined for a cantilever. When measuring the mechanical properties of materials, identifying and discerning the most influential parameters responsible for the observed changes in the cantilever response are important. We will, therefore, discuss the effects of various force fields such as those induced by mass loading, residual stress, internal friction of the material, and other changes in the mechanical properties of the microcantilevers. Methods to measure variations in temperature, pressure, or molecular adsorption of water molecules are also discussed. Often these effects occur simultaneously, increasing the number of parameters that need to be concurrently measured to ensure the reliability of the sensors. We therefore systematically investigate the geometric and environmental effects on cantilever measurements including the chemical nature of the underlying interactions. To address the geometric effects we have considered cantilevers with a rectangular or circular cross section. The chemical nature is addressed by using cantilevers fabricated with metals and/or dielectrics. Selective chemical etching, swelling or changes in Young’s modulus of the surface were investigated by means of polymeric and inorganic coatings. Finally to address the effect of the environment in which the cantilever operates, the Knudsen number was determined to characterize the molecule-cantilever collisions. Also bimaterial cantilevers with high thermal sensitivity were used to discern the effect of temperature variations. When appropriate, we use continuum mechanics, which is justified according to the ratio between the cantilever thickness and the grain size of the materials. We will also address other potential applications such as the ageing process of nuclear materials, building materials, and optical fibers, which can be investigated by monitoring their mechanical changes with time. In summary, by virtue of the dynamic response of a miniaturized cantilever shaped material, we present useful measurements of the associated elastic properties.

36 MATERIALS SCIENCE↗

A gradient-based optimization approach for the detection of partially connected surfaces using vibration tests

The integrity of engineering structures is often compromised by embedded surfaces that result from incomplete bonding during the manufacturing process, or initiation of damage from fatigue or impact processes. Examples include delaminations in composite materials, incomplete weld bonds when joining two components, and internal crack planes that may form when a structure is damaged. In many cases the areas of the structure in question may not be easily accessible, thus precluding the direct assessment of structural integrity. In this paper, we present a gradient-based, partial differential equation (PDE)-constrained optimization approach for solving the inverse problem of interface detection in the context of steady-state dynamics. An objective function is defined that represents the difference between the model predictions of structural response at a set of spatial locations, and the experimentally measured responses. One of the contributions of our work is a novel representation of the design variables using a density field that takes values in the range [0, 1] and raised to an integer exponent that promotes solutions to be near the extrema of the range. The density field is combined with the penalty method for enforcing a zero gap condition and realizing partially bonded surfaces. Furthermore the use of the penalty method with a density field representation leads to objective functions that are continuously differentiable with respect to the unknown parameters, enabling the use of efficient gradient-based optimization algorithms. Numerical examples of delaminated plates are presented to demonstrate the feasibility of the approach.

42 ENGINEERING↗

Comparison of theory with the experimental characterization of the spatial frequency response of interferometers using a binary pseudo-random array sample

Experimental evaluations of the surface height response of an interference microscope using a binary pseudo-random array test sample are compared with a theory based on a Fourier optics model. Measurements of key instrument characteristics, including the illumination, imaging, and obscuring apertures of three different Mirau objectives, support the theoretical calculations. Agreement between experimental and theoretical modeling confirms the predictability of the spatial frequency response for the purpose of specification and optimization of instrument configuration for specific metrology tasks. The results also provide confidence in methods of compensating for the decrease in instrument response with spatial frequency.

Calibration↗

Stochastic Seismic Response of an Algiers Site with Random Depth to Bedrock

Among the important effects of the Boumerdes earthquake (Algeria, May 21{sup st} 2003) was that, within the same zone, the destructions in certain parts were more important than in others. This phenomenon is due to site effects which alter the characteristics of seismic motions and cause concentration of damage during earthquakes. Local site effects such as thickness and mechanical properties of soil layers have important effects on the surface ground motions.This paper deals with the effect of the randomness aspect of the depth to bedrock (soil layers heights) which is assumed to be a random variable with lognormal distribution. This distribution is suitable for strictly non-negative random variables with large values of the coefficient of variation. In this case, Monte Carlo simulations are combined with the stiffness matrix method, used herein as a deterministic method, for evaluating the effect of the depth to bedrock uncertainty on the seismic response of a multilayered soil. This study considers a P and SV wave propagation pattern using input accelerations collected at Keddara station, located at 20 km from the epicenter, as it is located directly on the bedrock.A parametric study is conducted do derive the stochastic behavior of the peak ground acceleration and its response spectrum, the transfer function and the amplification factors. It is found that the soil height heterogeneity causes a widening of the frequency content and an increase in the fundamental frequency of the soil profile, indicating that the resonance phenomenon concerns a larger number of structures.

97 MATHEMATICS AND COMPUTING↗

Preparation, characterization of Fe3O4 at TiO2 magnetic nanoparticles and their application for immunoassay of biomarker of exposure to organophosphorus pesticides

Novel Fe3O4 at TiO2 magnetic nanoparticles were prepared and developed for a new nanoparticle-based immunosensor for electrochemical quantification of organophosphorylated butyrylcholinesterase (BChE) in plasma, a specific biomarker of exposure to organophosphorus (OP) agents. The Fe3O4 at TiO2 nanoparticles were synthesized by hydrolysis of tetrabutyltitanate on the surface of Fe3O4 magnetic nanospheres, and characterized by attenuated total reflection Fourier-transform infrared spectra, transmission electron microscope and X-ray diffraction. The functional Fe3O4 at TiO2 nanoparticles were performed as capture antibody to selectively enrich phosphorylated moiety instead of phosphoserine antibody in the traditional sandwich immunoassays. The secondary recognition was served by quantum dots (QDs)-tagged anti-BChE antibody (QDs-anti-BChE). With the help of a magnet, the resulting sandwich-like complex, Fe3O4 at TiO2/OP-BChE/QDs-anti-BChE, was easily isolated from sample solutions and the released cadmium ions were detected on a disposable screen-printed electrode (SPE). The binding affinities were investigated by both surface plasmon resonance (SPR) and square wave voltammetry (SWV). This method not only avoids the drawback of unavailability of commercial OP-specific antibody but also amplifies detection signal by QDs-tags together with easy separation of samples by magnetic forces. The proposed immunosensor yields a linear response over a broad OP-BChE concentrations range from 0.02 to 10 nM, with detection limit of 0.01 nM. Moreover, the disposable nanoparticle-based immunosensor has been validated with human plasma samples. It offers a new method for rapid, sensitive, selective and inexpensive screening/evaluating exposure to OP pesticides.

biomarker↗

Absolute spectral characterization of silicon barrier diode: Application to soft X-ray fusion diagnostics at Tore Supra

This paper presents an experimental protocol for absolute calibration of photo-detectors. Spectral characterization is achieved by a methodology that unlike the usual line emissions-based method, hinges on the Bremsstrahlung radiation of a Soft X-Ray (SXR) tube only. Although the proposed methodology can be applied virtually to any detector, the application presented in this paper is based on Tore Supra's SXR diagnostics, which uses Silicon Surface Barrier Diodes. The spectral response of these n-p junctions had previously been estimated on a purely empirical basis. This time, a series of second-order effects, like the spatial distribution of the source radiated power or multi-channel analyser non linearity, are taken into account to achieve accurate measurements. Consequently, a parameterised physical model is fitted to experimental results and the existence of an unexpected dead layer (at least 5 {mu}m thick) is evidenced. This contribution also echoes a more general on-going effort in favour of long-term quality of passive radiation measurements on Tokamaks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗