Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Intensity of the hydrogen peroxide v6/b/ band around 1266 cm

Laboratory spectra of the V6(b) band of H2O2 at 1266/cm have been obtained at a resolution of 0.06/cm and at temperatures ranging from 278 to 294 K. A total band intensity of 375 + or - 17 per sq cm per amagat is determined from the spectra. Special techniques to handle the H2O2 samples in a way that minimizes abundance determination errors are discussed.

Valero, F. P. J.↗

Search and retrieval of office files using dBASE 3

Described is a method of automating the office files retrieval process using a commercially available software package (dBASE III). The resulting product is a menu-driven computer program which requires no computer skills to operate. One part of the document is written for the potential user who has minimal computer experience and uses sample menu screens to explain the program; while a second part is oriented towards the computer literate individual and includes rather detailed descriptions of the methodology and search routines. Although much of the programming techniques are explained, this document is not intended to be a tutorial on dBASE III. It is hoped that the document will serve as a stimulus for other applications of dBASE III.

Breazeale, W. L.↗

Bioseparations - Flight experiment support research

While important principles of electrokinetic technology, such as electrophoresis, have been demonstrated for microgravity environments and promise to be able to alleviate many of the practical limitations imposed by gravity, the minimal crew time and sample-handling facilities available in orbit call for almost total reliance on postflight analysis of separated fractions. Since cell separations are the most difficult to accomplish in 1-g, two model cell types have been studied intensively to determine the basic relationships between cell surface charge and secretory functions. A rationale has been developed for selecting and qualifying new cell types and proteins that warrant processing in microgravity.

Morrison, Dennis R.↗

MBE growth technology for high quality strained III-V layers

The III-V films are grown on large automatically perfect terraces of III-V substrates which have a different lattice constant, with temperature and Group III and V arrival rates chosen to give a Group III element stable surface. The growth is pulsed to inhibit Group III metal accumulation of low temperature, and to permit the film to relax to equilibrium. The method of the invention: (1) minimizes starting step density on sample surface; (2) deposits InAs and GaAs using an interrupted growth mode (0.25 to 2 monolayers at a time); (3) maintains the instantaneous surface stoichiometry during growth (As-stable for GaAs, In-stable for InAs); and (4) uses time-resolved RHEED to achieve aspects (1) through (3).

Grunthaner, Frank J.↗

The MFIVE Space Station Crew Activity Scheduler and Stowage Logistics Clerk

An interactive computer scheduling tool, the MFIVE Space Station Crew Activity Scheduler and Stowage Logistics Clerk, is described. The MFIVE employs the intelligent perturbation method, which was developed to schedule complex time and resource constrained problems. This algorithm was used to minimize the completion time of sample scheduling problems and solutions were derived which averaged within 7 percent of optimum where standard solution techniques gave solutions 23 percent longer than optimum.

Kurtzman, Clifford R.↗

Reflectance spectroscopy of fresh whole leaves for the estimation of chemical concentration

Remotely sensed plant-canopy data in the visible and near-IR ranges are used to establish relations between the canopy reflectance and the chemical content of the leaves. The mathematical relation is generated by means of stepwise regression based on the derivative reflectance at certain wavelengths. Fourier filtering and sample control are used to minimize instrument noise and spectral overlap respectively, and absorption features are noted that correspond to sugar and protein. The coefficients of determination between estimated and measured concentrations are at least 0.82 for such substances as starch and chlorophyll. It is recommended in the analysis of remotly sensed canopy data that the chemicals with strong spectral overlaps with the chemical of interest be accounted for in order to estimate foliar chemical concentrations accurately.

Curran, Paul J.↗

Densities of 5-15 micron interplanetary dust particles

We have measured the densities of about 100 5-15 micron stratospheric IDPs. Great care was taken to minimize selection bias in the sample population. Masses were determined using an absolute x-ray analysis technique with a transmission electron microscope, and volumes were found using scanning electron microscope imagery. Unmelted chondritic particles have densities between 0.5 and 6.0 g/cc. Roughly half of the particles have densities below 2 g/cc, indicating appreciable porosity, but porosities greater than about 70 percent are rare. IDPs with densities above 3.5 g/cc usually contain large sulfide grains. We find no evidence of bimodality in the unmelted particle density distribution. Chondritic spherules (melted particles) have densities near 3.5 g/cc, consistent with previous results for deep sea spherules.

Love, S. G.↗

First results from a laboratory facility for measurement of emission spectra under simulated planetary conditions

We have developed a laboratory spectroscopic facility for the measurement of emission spectra under simulated planetary conditions. Spectral measurements are made from 6 to 13 microns with a scanning grating monochromator equipped with a HgCdTl detector. An environment chamber in service in Hawaii for several years in which we can control the temperature from 77 K to 500 K, the pressure from 10(exp -5) torr to two atmospheres, has been equipped with a 77 K or 273 K cold shield. The shield serves to minimize light reflected off the sample and to aid in development of thermal gradients for obtaining spectra under conditions simulating the thermal environment of airless bodies. Samples are placed in small cups on a temperature controlled substrate allowing measurements of emission due to heating from below by the substrate, or from illumination from a solar simulation source.

Lucey, Paul G.↗

Densities of stratospheric micrometeorites

We have measured the densities of roughly 150 5- to 15-microns interplanetary dust particles (IDPs) harvested in the stratosphere. Care was taken to minimize selection bias in the sample population. Masses were determined using an absolute X-ray analysis technique with a transmission electron microscope, and volumes were found using scanning electron microscope imagery. Unmelted chondritic particles have densities ranging between 0.3 and 6.2 g/cu cm, averaging 2.0 g/cu cm. The low medium densities indicates appreciable porosity, suggesting primitive, uncompacted parent bodies for these particles. Porosities greater than 70% are rare. IDPs with densities above 3.5 g/cu cm usually contain large sulfide grains. We find no evidence of bimodality in the unmelted particle density distribution. Chondritic spherules (melted particles) have densities near 3.4 g/cu cm, consistent with previous results for stony spheurles culled from deep-sea sediments.

Love, Stanley G.↗

Soot Precursor Material: Visualization Via Simultaneous LIF-LII and Characterization Via TEM

Simultaneous combined laser-induced fluorescence and laser-induced incandescence (LIF-LII) images are presented for both a normal and inverse diffusion flame. The excitation wavelength dependence distinguishes the LIF and LII signals in images from the normal diffusion flame while the temporal decay distinguishes the signals in images of the inverse diffusion flame. Each flame presents a minimum in the combined LIF-LII intensity in a region separating the fuel pyrolysis and soot containing regions. Opacity, geometric in definition, and extent of crystallinity measured through both bright and dark field Transmission Electron Microscopy (TEM) characterizes the thermophoretically sampled material from within this minimal LIF-LII intensity region. TEM analysis reveals rather different soot processes occurring within the normal and inverse diffusion flame. In the normal diffusion flame, rapid chemical and physical coalescence of PAHs results in initial formation of soot precursor particles that are highly crystalline and evolve toward fully formed soot. In the inverse diffusion flame, rapid coalescence of pyrolysis products occurs, producing tarlike, globular structures equivalent in size to fully formed soot aggregates but with markedly less crystallinity than normal-appearing soot. These different material properties are interpreted as reflecting different relative rates of chemical and physical coalescence of fuel pyrolysis products versus carbonization. Significantly, these TEM images support qualitative photophysical arguments suggesting that, in general, this 'dark' region observed in the LIF-LII images demarcates a transitional region in which a fundamental change in the material the material chemical/physical properties occurs between solid carbonaceous soot and condensed or gaseous molecular growth material.

VanderWal, Randall L.↗

Evaluation of Improved Pushback Forecasts Derived from Airline Ground Operations Data

Accurate and timely predictions of airline pushbacks can potentially lead to improved performance of automated decision-support tools for airport surface traffic, thus reducing the variability and average duration of costly airline delays. One factor which affects the realization of these benefits is the level of uncertainty inherent in the turn processes. To characterize this inherent uncertainty, three techniques are developed for predicting time-to-go until pushback as a function of available ground-time; elapsed ground-time; and the status (not-started/in-progress/completed) of individual turn processes (cleaning, fueling, etc.). These techniques are tested against a large and detailed dataset covering approximately l0(exp 4) real-world turn operations obtained through collaboration with Deutsche Lufthansa AG. Even after the dataset is filtered to obtain a sample of turn operations with minimal uncertainty, the standard deviation of forecast error for all three techniques is lower-bounded away from zero, indicating that turn operations have a significant stochastic component. This lower-bound result shows that decision-support tools must be designed to incorporate robust mechanisms for coping with pushback demand stochasticity, rather than treating the pushback demand process as a known deterministic input.

Carr, Francis↗

Facility and Methods Developed for Simulated Space Vacuum Ultraviolet Exposure Testing of Polymer Films

Vacuum ultraviolet (VUV) radiation of wavelengths between 115 and 200 nm produced by the Sun in the space environment can degrade polymer films, producing changes in their optical, mechanical, and chemical properties. These effects are particularly important for thin polymer films being considered for ultralightweight space structures, because, for most polymers, VUV radiation is absorbed in a thin surface layer. The NASA Glenn Research Center has developed facilities and methods for long-term ground testing of polymer films to evaluate space environmental VUV radiation effects. VUV exposure can also be used as part of combined or sequential simulated space environmental exposures to determine combined damaging effects with other aspects of the space environment, which include solar ultraviolet radiation, solar flare x-rays, electron and proton radiation, atomic oxygen (for low-Earth-orbit missions), and temperature effects. Because the wavelength sensitivity of VUV damage is not well known for most materials, Glenn's VUV facility uses a broad-spectrum deuterium lamp with a magnesium fluoride window that provides output between 115 and 200 nm. Deuterium lamps of this type were characterized by the National Institute of Standards and Technology and through measurements at Glenn. Spectral irradiance measurements show that from approximately 115 to 160 nm, deuterium lamp irradiance can be many times that of air mass zero solar irradiance, and as wavelength increases above approximately 160 nm, deuterium lamp irradiance decreases in comparison to the Sun. The facility is a cryopumped vacuum chamber that achieves a system pressure of approximately 5310(exp -6) torr. It contains four individual VUV-exposure compartments in vacuum, separated by water-cooled copper walls to minimize VUV radiation and any sample contamination cross interactions between compartments. Each VUV-exposure compartment contains a VUV deuterium lamp, a motor-controlled sample stage coupled with a moveable cesium iodide VUV phototube, and two thermocouples for temperature measurement. The vacuum chamber and exterior equipment is shown. Each VUV lamp is located at the top of the chamber with its projection-tube pushed through an O-ring compression fitting. The lamp assemblies are located on ports that can be isolated from the rest of the vacuum chamber, permitting maintenance or replacement of the lamps without breaking vacuum in the main chamber where the samples are located. A view of two of the four interior VUV-exposure compartments, including the moveable sample stages and detector holders is also shown. Glenn is using this facility to support testing of Next Generation Space Telescope sunshield materials that is being led by the NASA Goddard Space Flight Center and to develop an understanding of the wavelength, intensity, and temperature dependence of VUV-induced polymer degradation.

Dever, Joyce A.↗

Thermophysical Properties Measurements of Zr62Cu20Al10Ni8

Thermophysical property studies performed at high temperature can prove challenging because of reactivity problems brought on by the elevated temperatures. Contaminants from measuring devices and container walls can cause changes in properties. To prevent this, containerless processing techniques can be employed to isolate a sample during study. A common method used for this is levitation. Typical levitation methods used for containerless processing are, aerodynamically, electromagnetically and electrostatically based. All levitation methods reduce heterogeneous nucleation sites, 'which in turn provide access to metastable undercooled phases. In particular, electrostatic levitation is appealing because sample motion and stirring are minimized; and by combining it with optically based non-contact measuring techniques, many thermophysical properties can be measured. Applying some of these techniques, surface tension, viscosity and density have been measured for the glass forming alloy Zr62Cu20Al10Ni8 and will be presented with a brief overview of the non-contact measuring method used.

Bradshaw, Richard C.↗

MBE growth technology for high quality strained III-V layers

III-V films are grown on large automatically perfect terraces of III-V substrates which have a different lattice constant, with temperature and Group II and V arrival rates chosen to give a Group III element stable surface. The growth is pulsed to inhibit Group III metal accumulation to low temperature, and to permit the film to relax to equilibrium. The method of the invention 1) minimizes starting step density on sample surface; 2) deposits InAs and GaAs using an interrupted growth mode (0.25 to 2 mono-layers at a time); 3) maintains the instantaneous surface stoichiometry during growth (As-stable for GaAs, In-stable for InAs); and 4) uses time-resolved RHEED to achieve aspects (1)-14 (3).

Grunthaner, Frank J.↗

Partnering With NASA JSC for Community Research Needs; Collaborative and Student Opportunities via Jacobs and PSAMS Initiative

NASA Johnson Space Center's (JSC's) Astromaterials Research and Exploration Science (ARES) Division houses a unique combination of laboratories and other assets for conducting cutting-edge planetary research. These facilities have been accessed for decades by outside scientists; over the past five years, the 16 full time contract research and technical staff members in our division have hosted a total of 223 visiting researchers, representing 35 institutions. In order to continue to provide this level of support to the planetary sciences community, and also expand our services and collaboration within the broader scientific community, we intend to submit a proposal to NASA specifically for facilities support and establishment of our laboratories as a collective, PSAMS, Planetary Sample Analyses and Mission Science. This initiative should result in substantial cost savings to PIs with NASA funding who wish to use our facilities. Another cost saving could be realized by aggregating visiting user experiments and analyses through COMPRES, which would be of particular interest to researchers in earth and material sciences. JSC is a recognized NASA center of excellence for curation, and in future will allow PIs and mission teams easy access to samples in Curation facilities that they have been approved to study. Our curation expertise could also be used for a collection of experimental run products that could be shared and distributed to COMPRES community members. These experimental run products could range from 1 bar controlled atmosphere furnace, piston cylinder, multi-anvil, CETUS (see companion abstract), to shocked products. Coordinated analyses of samples is one of the major strengths of our division, where a single sample can be prepared with minimal destruction for a variety of chemical and structural analyses, from macro to nano-scale.

Danielson, Lisa↗

Partnering With NASA JSC for Community Research Needs; Collaborative and Student Opportunities via Jacobs and PSAMS Initiative

NASA Johnson Space Center's (JSC's) Astromaterials Research and Exploration Science (ARES) Division houses a unique combination of laboratories and other assets for conducting cutting-edge planetary research. These facilities have been accessed for decades by outside scientists; over the past five years, the 16 full time contract research and technical staff members in our division have hosted a total of 223 visiting researchers, representing 35 institutions. In order to continue to provide this level of support to the planetary sciences community, and also expand our services and collaboration within the broader scientific community, we intend to submit a proposal to NASA specifically for facilities support and establishment of our laboratories as a collective, PSAMS, Planetary Sample Analyses and Mission Science. This initiative should result in substantial cost savings to PIs with NASA funding who wish to use our facilities. Another cost saving could be realized by aggregating visiting user experiments and analyses through COMPRES, which would be of particular interest to researchers in earth and material sciences. JSC is a recognized NASA center of excellence for curation, and in future will allow PIs and mission teams easy access to samples in Curation facilities that they have been approved to study. Our curation expertise could also be used for a collection of experimental run products that could be shared and distributed to COMPRES community members. These experimental run products could range from 1 bar controlled atmosphere furnace, piston cylinder, multi-anvil, CETUS (see companion abstract), to shocked products. Coordinated analyses of samples is one of the major strengths of our division, where a single sample can be prepared with minimal destruction for a variety of chemical and structural analyses, from macro to nano-scale.

Danielson, Lisa↗

Subsampling of the Hamburg Meteorite: A Study in Cold Curation Techniques

The Hamburg meteorite is an H4 chondrite which was collected from the surface of a frozen lake in Michigan shortly after its observed fall on 16 Jan 2018 [1]. During and after collection, the meteorite was stored under clean, cold conditions, thereby minimizing any alteration to the sample. The meteorite was transported to the Johnson Space Center (JSC) where it was stored in a freezer until it was subsampled at the University of Alberta’s Sub-zero Facility for the Curation of Astromaterials (Fig. 1) [2]. Subsampling divided the meteorite into predefined target masses for preliminary examination and display purposes. This abstract summarizes the transport and subsampling process, which occurred in October 2019.

Mitchell, J. L.↗

Preserving and Curating the Moon: Adventures in Lunar Core Processing

The lunar crust is the most easily accessible part of the Moon to both remote sensing and sample analyses and provides an archive of information about planetary formation, crustal evolution, and contains a wealth of information about the origin of the Earth-Moon system [e.g., 1-5]. The Apollo mission returned 382 kg of rocks, soil and core samples. Studies of these lunar samples are crucial for our understanding of the Moon’s formation and geological evolution, and for the past 50 years these returned samples have provided the foundation for lunar science [5]. The returned samples are stored and cared for in the lunar curation facility at NASA’s Johnson Space Center. This facility is comprised of a large suite of clean rooms, sample vaults for pristine and return samples, thin section labs, core and saw rooms, storage and working areas, and ancillary labs all designed to minimize contamination from the environment and other samples. Some of the returned samples were intentionally set aside and left unopened. Recently, the Apollo Next Generation Sample Analysis (ANGSA) initiative was designed to examine these pristine samples so the next generation of lunar scientists can further our insight into the Moon’s history. Here, we present the meticulous process that involves preparing for, and ultimately opening, one of the unopened core samples: Apollo 17 drive tube 73002,0,which was collected on the Moon from a landslide deposit near Lara Crater by astronauts Gene Cernan and Jack Schmitt. In order to open, examine, and curate 73002,0withminimalpotential contamination, great care had to be taken prior to opening its container. Beginning18 months before extrusion of the sample, all core processing equipment was pulled out of storage, identified, sorted, cleaned, and purged with nitrogen gas. However, limited institutional memory has made this step challenging as most of the former core processors from the Apollo area have retired or passed away. Twelvemonths prior to extrusion, table-top rehearsals were initiated to identify equipment and learn how it fits together and operates. Five months before extruding the real core, preparations further evolved to include the extrusion and dissection of a lunar core simulant. In addition, a mock-up glovebox was designed and built to allow for a more realistic practice environment. One month prior to extrusion, the actual core cabinet was prepared for use, which included fitting it with lights, a webcam, and power. The tool and equipment cleaning procedure was also modified to include increased cleanliness and sterility requirements. While still sealed, the core was CT scanned at the University of Texas at Austin to maximize its scientific return. Days before the extrusion, witness plates and foil were deployed inside the core cabinet to monitor potential particle and organic contamination within the cabinet. On Nov. 5th, 2019, core sample 73002,0 was successfully opened and extruded(Fig.1). Dissection of 73002,0 began immediately afterwards and is still under way. Processing this sample will help us prepare for future sampling missions and core extrusions and will enable new scientific discoveries about the Moon.

C H Krysher↗