Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Synthesis of bulk FeHfBO soft magnetic materials and its loss characterization at megahertz frequency

Magnetic core materials with low loss, high saturation magnetization, large permeability, and operating frequency above 1 MHz are in high demands for the next generation of miniaturized power electronics. Amorphous FeHfB ribbons with thickness around 20 {mu}m have been fabricated through melt-spinning. Different heat treatments were performed on the FeHfB ribbons, and the relations among heat treatments, microstructure, and magnetic properties have been explored. Properties such as coercivity (H{sub c}) of 2.0 Oe and saturation magnetic flux density (B{sub S}) of 1.2 T have been achieved in samples with exchange coupling. The losses can be minimized by balancing the hysteretic and eddy current losses and can be further reduced with additional magnetic field annealing. At 5 MHz with peak magnetic flux density of 20 mT, the materials show core losses comparable to the best ferrites, but with higher permeability value of about 200 and superior saturation induction of more than 1 T.

36 MATERIALS SCIENCE↗

Equation of state of rhenium and application for ultra high pressure calibration

The isothermal equation of state of rhenium has been measured by powder X-ray diffraction experiments up to 144 GPa at room temperature in a diamond anvil cell. A helium pressure transmitting medium was used to minimize the non-hydrostatic stress on the sample. The fit of pressure-volume data yields a bulk modulus K{sub 0} = 352.6 GPa and a pressure derivative of the bulk modulus K′{sub 0}=4.56. This equation of state differs significantly from a recent determination [Dubrovinsky et al., Nat. Commun. 3, 1163 (2012)], giving here a lower pressure at a given volume. The possibility of using rhenium gasket X-ray diffraction signal, with the present equation of state, to evaluate multi-Mbar pressures in the chamber of diamond anvil cells is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimization of a tandem ion exchange—extraction chromatographic scheme for the recovery of strontium from raw urine

A previously reported ion-exchange/extraction chromatographic scheme for the recovery of radiostrontium from urine for subsequent determination is systematically optimized to minimize reagent consumption, enhance system reusability, and maximize sample throughput. In addition, a preliminary assessment of the effect of mobile phase flow rate on strontium uptake is described. Overall, the results show that the tandem system can be re-used without loss of performance, and that the rate at which samples can be processed by the system is ultimately limited by the time required for regeneration of the ion-exchange column and the kinetics of metal ion uptake on the extraction chromatographic sorbent.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Rapid estimation of earthquake locations using waveform traveltimes

SUMMARY We introduce a new approach for locating earthquakes using arrival times derived from waveforms. The most costly computational step of the algorithm scales as the number of stations in the active seismographic network. In this approach, a variation on existing grid search methods, a series of full waveform simulations are conducted for all receiver locations, with sources positioned successively at each station. The traveltime field over the region of interest is calculated by applying a phase picking algorithm to the numerical wavefields produced from each simulation. An event is located by subtracting the stored traveltime field from the arrival time at each station. This provides a shifted and time-reversed traveltime field for each station. The shifted and time-reversed fields all approach the origin time of the event at the source location. The mean or median value at the source location thus approximates the event origin time. Measures of dispersion about this mean or median time at each grid point, such as the sample standard error and the average deviation, are minimized at the correct source position. Uncertainty in the event position is provided by the contours of standard error defined over the grid. An application of this technique to a synthetic data set indicates that the approach provides stable locations even when the traveltimes are contaminated by additive random noise containing a significant number of outliers and velocity model errors. It is found that the waveform-based method out-performs one based upon the eikonal equation for a velocity model with rapid spatial variations in properties due to layering. A comparison with conventional location algorithms in both a laboratory and field setting demonstrates that the technique performs at least as well as existing techniques.

58 GEOSCIENCES↗

Charmonium and e + e - pair photoproduction at mid-rapidity in ultra-peripheral Pb–Pb collisions at $\sqrt{s_{\mathrm{NN}}} $ = 2.76 TeV

The ALICE Collaboration at the LHC has measured the J/ψ and ψ' photoproduction at mid-rapidity in ultra-peripheral Pb-Pb collisions at $\sqrt{s_{\mathrm{NN}}} $ = 2.76 Tev. The charmonium is identified via its leptonic decay for events where the hadronic activity is required to be minimal. The analysis is based on an event sample corresponding to an integrated luminosity of about 23 μb -1 . The cross section for coherent and incoherent J/ψ production in the rapidity interval -0.9 < y < 0.9, are dσ coh J/ψ /dy = 2.38 +0.34 –0.24 (sta + sys) mb and dσ inc J/ψ /dy = 0.98 +0.19 –0.17 (sta + sys) mb, respectively. The results are compared to theoretical models for J/ψ production and the coherent cross section is found to be in good agreement with those models incorporating moderate nuclear gluon shadowing at Bjorken-x around 10 –3 , such as EPS09 parametrization. In addition the cross section for the process γγ→e + e – has been measured and found to be in agreement with models implementing QED at leading order.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monoolein lipid phases as incorporation and enrichment materials for membrane protein crystallization.

The crystallization of membrane proteins in amphiphile-rich materials such as lipidic cubic phases is an established methodology in many structural biology laboratories. The standard procedure employed with this methodology requires the generation of a highly viscous lipidic material by mixing lipid, for instance monoolein, with a solution of the detergent solubilized membrane protein. This preparation is often carried out with specialized mixing tools that allow handling of the highly viscous materials while minimizing dead volume to save precious membrane protein sample. The processes that occur during the initial mixing of the lipid with the membrane protein are not well understood. Here we show that the formation of the lipidic phases and the incorporation of the membrane protein into such materials can be separated experimentally. Specifically, we have investigated the effect of different initial monoolein-based lipid phase states on the crystallization behavior of the colored photosynthetic reaction center from Rhodobacter sphaeroides. We find that the detergent solubilized photosynthetic reaction center spontaneously inserts into and concentrates in the lipid matrix without any mixing, and that the initial lipid material phase state is irrelevant for productive crystallization. A substantial in-situ enrichment of the membrane protein to concentration levels that are otherwise unobtainable occurs in a thin layer on the surface of the lipidic material. These results have important practical applications and hence we suggest a simplified protocol for membrane protein crystallization within amphiphile rich materials, eliminating any specialized mixing tools to prepare crystallization experiments within lipidic cubic phases. Furthermore, by virtue of sampling a membrane protein concentration gradient within a single crystallization experiment, this crystallization technique is more robust and increases the efficiency of identifying productive crystallization parameters. Finally, we provide a model that explains the incorporation of the membrane protein from solution into the lipid phase via a portal lamellar phase.

59 BASIC BIOLOGICAL SCIENCES↗

Compressed sensing with sparse corruptions: Fault-tolerant sparse collocation approximations

The recovery of approximately sparse or compressible coefficients in a polynomial chaos expansion is a common goal in many modern parametric uncertainty quantification (UQ) problems. However, relatively little effort in UQ has been directed toward theoretical and computational strategies for addressing the sparse corruptions problem, where a small number of measurements are highly corrupted. Such a situation has become pertinent today since modern computational frameworks are sufficiently complex with many interdependent components that may introduce hardware and software failures, some of which can be difficult to detect and result in a highly polluted simulation result. In this paper we present a novel compressive sampling-based theoretical analysis for a regularized t1 minimization algorithm that aims to recover sparse expansion coefficients in the presence of measurement corruptions. Our recovery results are uniform (the theoretical guarantees hold for all compressible signals and compressible corruptions vectors), and prescribe algorithmic regularization parameters in terms of a user-defined a priori estimate on the ratio of measurements that are believed to be corrupted. We also propose an iteratively reweighted optimization algorithm that automatically refines the value of the regularization parameter, and empirically produces superior results. Our numerical results test our framework on several medium-to-high dimensional examples of solutions to parameterized differential equations, and demonstrate the effectiveness of our approach.

97 MATHEMATICS AND COMPUTING↗

Specification of Radionuclide Classes for MELCOR Molten Salt Reactor Simulations

MELCOR has been used extensively to facilitate virtual investigations into severe nuclear accidents for light-water reactors (LWRs). Non-light water reactors (non-LWRs) render some LWR-centric approaches potentially unsuitable. MELCOR has been instrumental in analyzing source terms for LWRs and has recently expanded its applicability to non-LWRs. To simplify radionuclide (RN) tracking, MELCOR currently groups elements into 17 classes, each containing representative species. This grouping, optimized for LWRs, is not appropriate for non-LWRs due to the different chemistry. This necessitates a reevaluation of radionuclide transport modeling. This report introduces a new class scheme for MELCOR tailored to MSR modeling, expanding the current 17 classes to 32 and are explained in the context of a UF 4 fueled FLiBe carrier MSR. It provides a discussion and justification for the new groupings and outlines a methodology for discovering and defining additional classes in MELCOR using a sample calculated RN inventory and a Gibbs energy minimizer (GEM).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Grazing exit versus grazing incidence geometry for x-ray absorption near edge structure analysis of arsenic traces

In the presented study the grazing exit x-ray fluorescence was tested for its applicability to x-ray absorption near edge structure analysis of arsenic in droplet samples. The experimental results have been compared to the findings of former analyses of the same samples using a grazing incidence (GI) setup to compare the performance of both geometries. Furthermore, the investigations were accomplished to gain a better understanding of the so called self-absorption effect, which was observed and investigated in previous studies using a GI geometry. It was suggested that a normal incidence-grazing-exit geometry would not suffer from self-absorption effects in x-ray absorption fine structure (XAFS) analysis due to the minimized path length of the incident beam through the sample. The results proved this assumption and in turn confirmed the occurrence of the self-absorption effect for GI geometry. Due to its lower sensitivity it is difficult to apply the GE geometry to XAFS analysis of trace amounts (few nanograms) of samples but the technique is well suited for the analysis of small amounts of concentrated samples.

36 MATERIALS SCIENCE↗

Demonstration of an AI-driven workflow for autonomous high-resolution scanning microscopy

Abstract Modern scanning microscopes can image materials with up to sub-atomic spatial and sub-picosecond time resolutions, but these capabilities come with large volumes of data, which can be difficult to store and analyze. We report the Fast Autonomous Scanning Toolkit (FAST) that addresses this challenge by combining a neural network, route optimization, and efficient hardware controls to enable a self-driving experiment that actively identifies and measures a sparse but representative data subset in lieu of the full dataset. FAST requires no prior information about the sample, is computationally efficient, and uses generic hardware controls with minimal experiment-specific wrapping. We test FAST in simulations and a dark-field X-ray microscopy experiment of a WSe 2 film. Our studies show that a FAST scan of <25% is sufficient to accurately image and analyze the sample. FAST is easy to adapt for any scanning microscope; its broad adoption will empower general multi-level studies of materials evolution with respect to time, temperature, or other parameters.

47 OTHER INSTRUMENTATION↗

Temperature gradients for thermophysical and thermochemical property measurements to 3000 °C for an aerodynamically levitated spheroid

This study examines thermal gradients in ceramic oxide spheroids being aerodynamically levitated in a conical nozzle levitator (CNL) system equipped with a CO 2 laser (10.6 μm wavelength). The CNL system is a versatile piece of equipment that can easily be coupled with advanced thermophysical and thermochemical measuring devices, such as diffraction/scattering (X-ray and neutron), nuclear magnetic resonance, and calorimetry, for the analysis of bulk spheroidal solids and liquids. The thermal gradients of a series of single crystal, polycrystalline solids, and liquid spheroids have been measured spatially in the CNL system, by means of a disappearing filament pyrometer (800-3000 °C) and by X-ray diffraction with reference to an internal standard (Pt: 800-1600 °C). The thermal gradient in a levitated sample being heated by a laser from the top can be minimized by: (i) maximizing the sphericity, (ii) maximizing the density, and (iii) minimizing microstructural features. A spheroid with these properties can be manufactured via machining a perfect sphere from a highly dense, chemically and phase pure pellet. These properties promote rotation of the sample about multiple axes in the air stream, enabling homogeneous heating. This homogeneous heating is the dominant factor in reducing thermal gradients in solid state samples. It was found that the thermal gradient in an similar to 3 mm diameter solid sample could be reduced from 1000 °C to 30 °C, by having a perfectly spherical shape that could rotate on multiple axes in a high velocity gas stream (similar to 1500-2000 cm 3 /min). As a result, these findings will allow accurate thermophysical and thermochemical property measurements of solids in situ at high temperatures, using the CNL system.

47 OTHER INSTRUMENTATION↗

Prospective Evaluation to Establish a Dose Response for Clinical Oral Mucositis in Patients Undergoing Head-and-Neck Conformal Radiotherapy

Purpose: We conducted a clinical study to correlate oral cavity dose with clinical mucositis, perform in vivo dosimetry, and determine the feasibility of obtaining buccal mucosal cell samples in patients undergoing head-and-neck radiation therapy. The main objective is to establish a quantitative dose response for clinical oral mucositis. Methods and Materials: Twelve patients undergoing radiation therapy for head-and-neck cancer were prospectively studied. Four points were chosen in separate quadrants of the oral cavity. Calculated dose distributions were generated by using AcQPlan and Eclipse treatment planning systems. MOSFET dosimeters were used to measure dose at each sampled point. Each patient underwent buccal sampling for future RNA analysis before and after the first radiation treatment at the four selected points. Clinical and functional mucositis were assessed weekly according to National Cancer Institute Common Toxicity Criteria, Version 3. Results: Maximum and average doses for sampled sites ranged from 7.4-62.3 and 3.0-54.3 Gy, respectively. A cumulative point dose of 39.1 Gy resulted in mucositis for 3 weeks or longer. Mild severity (Grade {<=} 1) and short duration ({<=}1 week) of mucositis were found at cumulative point doses less than 32 Gy. Polymerase chain reaction consistently was able to detect basal levels of two known radiation responsive genes. Conclusions: In our sample, cumulative doses to the oral cavity of less than 32 Gy were associated with minimal acute mucositis. A dose greater than 39 Gy was associated with longer duration of mucositis. Our technique for sampling buccal mucosa yielded sufficient cells for RNA analysis using polymerase chain reaction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prevalence of elevated blood lead levels among pregnant women and sources of lead exposure in rural Bangladesh: A case control study

Highlights: • Prenatal blood lead levels and lead sources are assessed in rural Bangladesh. • Elevated blood lead levels are found among pregnant women. • Multiple possible sources of lead are identified; all related to food. • Future lead prevention studies should investigate food storage and production. Prenatal and early childhood lead exposures impair cognitive development. We aimed to evaluate the prevalence of elevated blood lead levels (BLLs) among pregnant women in rural Bangladesh and to identify sources of lead exposure. We analyzed the BLLs of 430 pregnant women randomly selected from rural communities in central Bangladesh. Fifty-seven cases were selected with the highest BLLs, ≥ 7 μg/dL, and 59 controls were selected with the lowest BLLs, < 2 μg/dL. An exposure questionnaire was administered and soil, rice, turmeric, water, traditional medicine, agrochemical, and can samples were analyzed for lead contamination. Of all 430 women, 132 (31%) had BLLs > 5 μg/dL. Most women with elevated BLLs were spatially clustered. Cases were 2.6 times more likely than controls to consume food from a can (95% CI 1.0–6.3, p = 0.04); 3.6 times more likely to use Basudin, a specific brand of pesticide (95% CI 1.6–7.9, p = 0.002); 3.6 times more likely to use Rifit, a specific brand of herbicide (95% CI 1.7–7.9, p = 0.001); 2.9 times more likely to report using any herbicides (95% CI 1.2–7.3, p = 0.02); and 3.3 times more likely to grind rice (95% CI 1.3–8.4, p = 0.01). Five out of 28 food storage cans were lead-soldered. However, there was minimal physical evidence of lead contamination from 382 agrochemical samples and 129 ground and unground rice samples. Among 17 turmeric samples, one contained excessive lead (265 μg/g) and chromium (49 μg/g). Overall, we found evidence of elevated BLLs and multiple possible sources of lead exposure in rural Bangladesh. Further research should explicate and develop interventions to interrupt these pathways.

54 ENVIRONMENTAL SCIENCES↗

High-temperature oxidation kinetics of sponge-based E110 cladding alloy

Two-sided oxidation experiments were recently conducted at 900°C–1200 °C in flowing steam with samples of sponge-based Zr-1Nb alloy E110. Although the old electrolytic E110 tubing exhibited a high degree of susceptibility to nodular corrosion and experienced breakaway oxidation rates in a relatively short time, the new sponge-based E110 demonstrated steam oxidation behavior comparable to Zircaloy-4. Sample weight gain and oxide layer thickness measurements were performed on oxidized E110 specimens and compared to oxygen pickup and oxide layer thickness calculations using the Cathcart-Pawel correlation. Our study shows that the sponge-based E110 follows the parabolic law at temperatures above 1015 °C. At or below 1015 °C, the oxidation rate was very low when compared to Zircaloy-4 and can be represented by a cubic expression. No breakaway oxidation was observed at 1000 °C for oxidation times up to 10,000 s. Arrhenius expressions are given to describe the parabolic rate constants at temperatures above 1015 °C and cubic rate constants are provided for temperatures below 1015 °C. The weight gains calculated by our equations are in excellent agreement with the measured sample weight gains at all test temperatures. In addition to the as-fabricated E110 cladding sample, prehydrided E110 cladding with hydrogen concentrations in the 100–150 wppm range was also investigated. The effect of hydrogen content on sponge-based E110 oxidation kinetics was minimal. No significant difference was found between as-fabricated and hydrided samples with regard to oxygen pickup and oxide layer thickness for hydrogen contents below 150 wppm.

36 MATERIALS SCIENCE↗

Fuel Thermo-physical Characterization Project: Evaluation of Models to Calculate Thermal Diffusivity of Layered Composites

The Office of Material Management and Minimization Fuel Thermo-physical Characterization Project at Pacific Northwest National Laboratory (PNNL) is tasked with using PNNL facilities and processes to receive irradiated low enriched uranium-molybdenum fuel plate samples and perform analyses in support of the Office of Material Management and Minimization Reactor Conversion Program. This work is in support of the Fuel Development Pillar that is managed by Idaho National Laboratory. A key portion of the scope associated with this project was to measure the thermal properties of fuel segments harvested from plates that were irradiated in the Advanced Test Reactor. Thermal diffusivity of samples prepared from the fuel segments was measured using laser flash analysis. Two models, one developed by PNNL and the other developed by the Technische Universität München (TUM), were evaluated to extract the thermal diffusivity of the uranium-molybdenum alloy from measurements made on the irradiated, layered composites. The experimental data of the “TC” irradiated fuel segment was evaluated using both models considering a three-layer and five-layer system. Both models are in acceptable agreement with one another and indicate that the zirconium diffusion barrier has a minimal impact on the overall thermal diffusivity of the monolithic U-Mo fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Raster-scanning serial protein crystallography using micro- and nano-focused synchrotron beams

A raster scanning serial protein crystallography approach is presented, that consumes as low ∼200–700 nl of sedimented crystals. New serial data pre-analysis software, NanoPeakCell, is introduced. High-resolution structural information was obtained from lysozyme microcrystals (20 µm in the largest dimension) using raster-scanning serial protein crystallography on micro- and nano-focused beamlines at the ESRF. Data were collected at room temperature (RT) from crystals sandwiched between two silicon nitride wafers, thereby preventing their drying, while limiting background scattering and sample consumption. In order to identify crystal hits, new multi-processing and GUI-driven Python-based pre-analysis software was developed, named NanoPeakCell, that was able to read data from a variety of crystallographic image formats. Further data processing was carried out using CrystFEL, and the resultant structures were refined to 1.7 Å resolution. The data demonstrate the feasibility of RT raster-scanning serial micro- and nano-protein crystallography at synchrotrons and validate it as an alternative approach for the collection of high-resolution structural data from micro-sized crystals. Advantages of the proposed approach are its thriftiness, its handling-free nature, the reduced amount of sample required, the adjustable hit rate, the high indexing rate and the minimization of background scattering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Digital Electronics For The Versatile Array Of Neutron Detectors At Low Energies

A {chi}{sup 2} minimization algorithm has been developed to extract sub-sampling-time information from digitized waveforms, to be used to instrument the future Versatile Array of Neutron Detectors at Low energies. The algorithm performance has been characterized with a fast Arbitrary Function Generator, obtaining time resolution better than 1 ns for signals of amplitudes between 50 mV and 1V, with negligible walk in the whole range. The proof-of-principle measurement of the beta-delayed neutron emission from {sup 89}Br indicates a resolution of 1 ns can be achieved in realistic experimental conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rigorous Two-Step Activation for Fusion Systems with PyNE - Paper 127

In fusion systems, high energy neutrons activate system components. After shutdown, the biological dose rate from photons emitted from these components must be estimated as a function of position and time for maintenance planning. High resolution results can be obtained using the mesh-based Rigorous Two-Step (R2S) method. A neutron transport simulation provides mesh-based neutron fluxes. Using these fluxes and an appropriate irradiation scenario, a nuclear inventory analysis code is used to determine the photon source density within each mesh volume element at any decay time after shutdown. The photon source density mesh is used as a source for photon transport. Photon fluxes are tallied at positions of interest and flux-to-dose rate conversion factors are used to estimate the biological dose rate. Previous work by the authors involved the creation of R2S-ACT, an open source R2S workflow, using the Direct Accelerated Geometry Monte Carlo (DAGMC) version of MCNP5 (DAG-MCNP5) for both transport steps and the ALARA nuclear inventory analysis code. Various use cases may require different combinations of transport and activation codes, and nearly all of the capabilities of R2S-ACT have broader utility. For these reasons, the individual components of R2S-ACT were reimplemented within PyNE. PyNE is a collaborative, trans-institutional, open source project consisting of Python, Cython, and C++ code pertinent to nuclear simulations and analysis. This work involved additions to the PyNE mcnp, mesh, material, alara, dagmc, and sampling modules. A lightweight r2s module was then added to connect the code from these modules. The r2s and sampling modules, together with DAG-MCNP5 and ALARA form a complete R2S workflow for obtaining shutdown dose rate results. Mesh operations, geometry discretization, physics code input/output parsing, and mesh-based source sampling capabilities have been added to PyNE generically, eliminating the need to duplicate this effort across multiple applications. The PyNE r2s module uses these capabilities to couple MCNP and ALARA to form an R2S workflow, which has been validated with the FNG shutdown dose rate benchmark. Future work will involve benchmarking the workflow using tetrahedral mesh and also non-analog sampling options. added so that they can be used interchangeably. This will allow for comparisons between results obtained by different physics codes with minimal human effort. Work will also be done to create and implement an importance sampling method for biasing neutron transport towards regions of phase space of high importance to photon dose rate tallies. This will improve the efficiency of obtaining shutdown dose rate results in large, highly-attenuating geometries. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗