Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling bias”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Sampling on NISQ Devices: "Who’s the Fairest One of All?"

Modern NISQ devices are subject to a variety of biases and sources of noise that degrade the solution quality of computations carried out on these devices. A natural question that arises in the NISQ era, is how fairly do these devices sample ground state solutions. To this end, we run five fair sampling problems (each with at least three ground state solutions) that are based both on quantum annealing and, on the Grover Mixer, -QAOA algorithm for gate-based NISQ hardware. In particular, we use seven IBM Q devices, the Aspen-9 Rigetti device, the IonQ device, and three D-Wave quantum annealers. For each of the fair sampling problems, we measure the ground state probability, the relative fairness of the frequency of each ground state solution with respect to the other ground state solutions, and the aggregate error as given by each hardware provider. Overall, our results show that NISQ devices do not achieve fair sampling yet. Furthermore, we also observe differences in the software stack with a particular focus on compilation techniques that illustrate what work will still need to be done to achieve a seamless integration of frontend (i.e., quantum circuit description) and backend compilation.

Computer Science↗

Cosmogenic 3 He exposure dating in mafic rocks by “Virtual mineral separation” of pyroxene

We describe a “virtual mineral separation” method for measuring the cosmogenic 3 He concentration in pyroxene in mafic rocks that consist mainly of plagioclase and pyroxene, without physically separating the minerals. This approach is significantly faster and more cost-effective than the conventional method, which requires physical separation and purification of pyroxene grains by time-consuming and labor-intensive crushing, acid cleaning, magnetic separation, HF etching, and handpicking under a microscope. The premise of the method is that helium diffusivity is much higher in plagioclase than in pyroxene, so controlled preheating of a mixed whole-rock sample can degas 3 He from plagioclase while retaining all 3 He in pyroxene. A second heating step releases all 3 He from pyroxene for measurement. To then obtain a 3 He concentration in pyroxene rather than the whole rock, we determine the pyroxene weight fraction in the sample using X-ray computed tomography (CT). A comparison of 3 He concentrations in pyroxene measured using virtual mineral separation with those measured in the same samples by physical mineral separation in previous work shows no evidence of systematic bias between the methods. Virtual mineral separation greatly simplifies the workflow for 3 He exposure-dating of mafic rocks, reduces time, effort, and cost, and permits measurements on very small samples. This enables new emerging applications of exposure dating, such as quantifying stochastic surface processes, ecosystem studies, and potential subglacial bedrock exposure dating.

Geosciences↗

Redshifting galaxies from DESI to JWST CEERS: Correction of biases and uncertainties in quantifying morphology

Observations of high-redshift galaxies with unprecedented detail have now been rendered possible with the James Webb Space Telescope (JWST). However, accurately quantifying their morphology remains uncertain due to potential biases and uncertainties. To address this issue, we used a sample of 1816 nearby DESI galaxies, with a stellar mass range of 10 9.75 - 11.25 M ⊙ , to compute artificial images of galaxies of the same mass located at 0.75 ≤ z ≤ 3 and observed at rest-frame optical wavelength in the Cosmic Evolution Early Release Science (CEERS) survey. We analyzed the effects of cosmological redshift on the measurements of Petrosian radius (R p ), half-light radius (R 50 ), asymmetry (A), concentration (C), axis ratio (q), and Sérsic index (n). Our results show that R p and R 50 , calculated using non-parametric methods, are slightly overestimated due to PSF smoothing, while R 50 , q, and n obtained through fitting a Sérsic model does not exhibit significant biases. By incorporating a more accurate noise effect removal procedure, we improve the computation of A over existing methods, which often overestimate, underestimate, or lead to significant scatter of noise contributions. Due to PSF asymmetry, there is a minor overestimation of A for intrinsically symmetric galaxies. However, for intrinsically asymmetric galaxies, PSF smoothing dominates and results in an underestimation of A, an effect that becomes more significant with higher intrinsic A or at lower resolutions. Moreover, PSF smoothing also leads to an underestimation of C, which is notably more pronounced in galaxies with higher intrinsic C or at lower resolutions. We developed functions based on resolution level, defined as R p /FWHM, for correcting these biases and the associated statistical uncertainties. Applying these corrections, we measured the bias-corrected morphology for the simulated CEERS images and we find that the derived quantities are in good agreement with their intrinsic values – except for A, which is robust only for angularly large galaxies where R p /FWHM ≥ 5. Our correction functions can be applied to other surveys, offering valuable tools for future studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Development and cross‐validation of a circumference‐based predictive equation to estimate body fat in an active population

Abstract Objective The U.S. Army uses sex‐specific circumference‐based prediction equations to estimate percent body fat (%BF) to evaluate adherence to body composition standards. The equations are periodically evaluated to ensure that they continue to accurately assess %BF in a diverse population. The objective of this study was to develop and validate alternative field expedient equations that may improve upon the current Army Regulation (AR) body fat (%BF) equations. Methods Body size and composition were evaluated in a representatively sampled cohort of 1904 active‐duty Soldiers (1261 Males, 643 Females), using dual‐energy X‐ray absorptiometry (%BF DXA ), and circumferences obtained with 3D imaging and manual measurements. Sex stratified linear prediction equations for %BF were constructed using internal cross validation with %BF DXA as the criterion measure. Prediction equations were evaluated for accuracy and precision using root mean squared error, bias, and intraclass correlations. Equations were externally validated in a convenient sample of 1073 Soldiers. Results Three new equations were developed using one to three circumference sites. The predictive values of waist, abdomen, hip circumference, weight and height were evaluated. Changing from a 3‐site model to a 1‐site model had minimal impact on measurements of model accuracy and performance. Male‐specific equations demonstrated larger gains in accuracy, whereas female‐specific equations resulted in minor improvements in accuracy compared to existing AR equations. Equations performed similarly in the second external validation cohort. Conclusions The equations developed improved upon the current AR equation while demonstrating robust and consistent results within an external population. The 1‐site waist circumference‐based equation utilized the abdominal measurement, which aligns with associated obesity related health outcomes. This could be used to identify individuals at risk for negative health outcomes for earlier intervention.

Taylor, Kathryn M.↗

Halo Properties and Mass Functions of Groups/Clusters from the DESI Legacy Imaging Surveys DR9

Abstract Based on a large group/cluster catalog recently constructed from the DESI Legacy Imaging Surveys DR9 using an extended halo-based group finder, we measure and model the group–galaxy weak-lensing signals for groups/clusters in a few redshift bins within redshift range 0.1 ≤ z < 0.6. Here, the background shear signals are obtained based on the DECaLS survey shape catalog, derived with the F ourier _Q uad method. We divide the lens samples into five equispaced redshift bins and seven mass bins, which allow us to probe the redshift and mass dependence of the lensing signals, and hence the resulting halo properties. In addition to these sample selections, we also check the signals around different group centers, e.g., the brightest central galaxy, the luminosity-weighted center, and the number-weighted center. We use a lensing model that includes off-centering to describe the lensing signals that we measure for all mass and redshift bins. The results demonstrate that our model predictions for the halo masses, biases, and concentrations are stable and self-consistent among different samples for different group centers. Taking advantage of the very large and complete sample of groups/clusters, as well as the reliable estimations of their halo masses, we provide measurements of the cumulative halo mass functions up to redshift z = 0.6, with a mass precision at 0.03 ∼ 0.09 dex.

79 ASTRONOMY AND ASTROPHYSICS↗

The asymmetric distribution of satellite galaxy velocities

Companion galaxies tend to have redshifts that exceed that of their associated primary. We show that the latest sample of satellite galaxies (from Zaritsky et al.) corroborates this assertion. We examine whether selection biases and contamination by galaxies that are not physical satellites can create the observed velocity asymmetry. As shown by Valtonen and Byrd (1986) for previous samples, simple models of the selection process reproduce the sense of the asymmetry, but not its magnitude unless the samples are dominated by interlopers. We expand on this model by using numerical simulations that include a simple model of galaxy clustering, and demonstrate that clustering can increase the magnitude of the expected asymmetry for a particular level of contamination. Depending on input assumptions, these models imply 1 sigma lower limits on the contamination level in the Zaritsky et al. (1992) sample of between 8 and 20 percent. Using the results from the analysis of that sample and the models, we conclude that, for the type of satellite galaxy sample discussed, here, a moderate level of contamination (about 10 percent) is sufficient to account for the observed asymmetry.

Zaritsky, Dennis↗

Evaluating CERES TOA Fluxes using ARISE aircraft observations

Uncertainty in observations of top-of-atmosphere (TOA) radiation fluxes are larger in the Arctic than in other regions. The magnitude of these uncertainties limit our understanding of the Arctic surface energy budget and its variability. The significant uncertainties are due to the low sun angles and wide range of highly reflecting, anisotropic, and highly heterogeneous surface conditions. Therefore, quantifying, attributing, and reducing Arctic TOA radiative flux uncertainty enables a better understanding of the rapidly changing Arctic. To advance this goal, we compare the Cloud and Earth’s Radiant Energy System (CERES) TOA radiative fluxes with measurements from the Arctic Radiation-IceBridge Sea and Ice Experiment (ARISE) flow in September 2014. A key objective of ARISE was to evaluate and attribute uncertainty in CERES footprint and gridded TOA radiative fluxes. In this study, we first compare the CERES TOA flux with those obtained from the broadband radiometer measurements from the aircraft using instantaneously matched footprint with the flight track and as the hourly gridded fluxes. This comparison indicates an agreement within uncertainty in the longwave (2 Wm-2 ) for all five grid boxes and agreement in the shortwave (10 Wm-2) for four-out-of-five grid boxes. While not a statistically significant results given the small sample size, the hourly, gridded and the instantaneously matched footprint comparison suggest a -10 Wm-2 bias for CERES in the shortwave. To explore whether this is a robust feature or a statistical artifact, we quantify the individual sources of uncertainty in the differences (temporal and spatial sampling differences, scene evolution, accuracy, angular distribution models, and scene id) to see if any of these differences account for the shortwave bias.

CERES↗

Risk Assessment of Rare Events in Probabilistic Power Flow via Hybrid Multi-Surrogate Method

The risks associated with rare events threatening the security of power system operation are of paramount importance to power system planners and operators. To analyze the risks caused by high-impact, low-frequency rare events, an immensely large number of samples are typically required for the Monte-Carlo (MC) method on the high-fidelity power system model to achieve a sufficient accuracy, thereby rendering this approach computationally prohibitive. To handle this problem efficiently, it is desirable to construct a surrogate model for the power system response. However, the straightforward MC sampling of the low-fidelity surrogate can lead to biased results in the low-probability tail regions that are vital to risk assessment. Moreover, a single surrogate is unable to handle the topology uncertainties caused by random branch outages. To overcome these issues, we propose a hybrid multi-surrogate (HMS) method based on the polynomial chaos expansion (PCE) with low-probability tail events reevaluated by the high-fidelity model through a probabilistic analysis. This method improves the computational efficiency of the MC method for rare-event risk assessment by leveraging multi-fidelity models while retaining the desired accuracy. Simulations conducted in three test systems verify the excellent performances of the HMS method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Constraining primordial non-Gaussianity with DESI 2024 LRG and QSO samples

We analyse the large-scale clustering of the Luminous Red Galaxy (LRG) and Quasar (QSO) sample from the first data release (DR1) of the Dark Energy Spectroscopic Instrument (DESI). In particular, we constrain the primordial non-Gaussianity (PNG) parameter f NL loc via the large-scale scale-dependent bias in the power spectrum using 1,631,716 LRGs (0.6 < z < 1.1) and 1,189,129 QSOs (0.8 < z < 3.1). This new measurement takes advantage of the enormous statistical power at large scales of DESI DR1 data, surpassing the latest data release (DR16) of the extended Baryon Oscillation Spectroscopic Survey (eBOSS). For the first time in this kind of analysis, we use a blinding procedure to mitigate the risk of confirmation bias in our results. We improve the model of the radial integral constraint proposing an innovative technique allowing the correction through the window matrix convolution. We also carefully test the mitigation of the dependence of the target selection on the photometry qualities by incorporating an angular integral constraint contribution to the window function, and validate our methodology with the blinded data. Finally, combining the two samples, we measure f NL loc = -3.6 -9.1 +9.0 at 68% confidence, where we assume the universality relation for the LRG sample and a recent merger model for the QSO sample about the response of bias to primordial non-Gaussianity. Adopting the universality relation for the PNG bias in the QSO analysis leads to f NL loc = 3.5 -7.4 +10.7 at 68% confidence. Due to restricted selection in the LRG sample, the inclusion of the LRGs allows for 10% improvement. This measurement is the most precise determination of primordial non-Gaussianity using large-scale structure to date, surpassing the latest result from eBOSS by a factor of 2.3.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of a Multi-Parameter Sensor for Automated, Continuous Cell Culture Monitoring in Bioreactors

Compact and automated sensors are desired for assessing the health of cell cultures in biotechnology experiments in microgravity. Measurement of cell culture medium allows for the optirn.jzation of culture conditions on orbit to maximize cell growth and minimize unnecessary exchange of medium. While several discrete sensors exist to measure culture health, a multi-parameter sensor would simplify the experimental apparatus. One such sensor, the Paratrend 7, consists of three optical fibers for measuring pH, dissolved oxygen (p02), dissolved carbon dioxide (pC02) , and a thermocouple to measure temperature. The sensor bundle was designed for intra-arterial placement in clinical patients, and potentially can be used in NASA's Space Shuttle and International Space Station biotechnology program bioreactors. Methods: A Paratrend 7 sensor was placed at the outlet of a rotating-wall perfused vessel bioreactor system inoculated with BHK-21 (baby hamster kidney) cells. Cell culture medium (GTSF-2, composed of 40% minimum essential medium, 60% L-15 Leibovitz medium) was manually measured using a bench top blood gas analyzer (BGA, Ciba-Corning). Results: A Paratrend 7 sensor was used over a long-term (>120 day) cell culture experiment. The sensor was able to track changes in cell medium pH, p02, and pC02 due to the consumption of nutrients by the BHK-21. When compared to manually obtained BGA measurements, the sensor had good agreement for pH, p02, and pC02 with bias [and precision] of 0.02 [0.15], 1 mm Hg [18 mm Hg], and -4.0 mm Hg [8.0 mm Hg] respectively. The Paratrend oxygen sensor was recalibrated (offset) periodically due to drift. The bias for the raw (no offset or recalibration) oxygen measurements was 42 mm Hg [38 mm Hg]. The measured response (rise) time of the sensor was 20 +/- 4s for pH, 81 +/- 53s for pC02, 51 +/- 20s for p02. For long-term cell culture measurements, these response times are more than adequate. Based on these findings , the Paratrend sensor could offer automated, continuous monitoring of cell cultures with a temporal resolution of 1 minute, which is not attainable by sampling via handheld blood analyzer (i-STAT). Conclusion: The resulting bias and precision found in these cell culture-based studies is comparable to Paratrend sensor clinical results. Although the large error in p02 measurements (+/-18 mm Hg) may be acceptable for clinical applications, where Paratrend values are periodically adjusted to a BGA measurement, the O2 sensor in this bundle may not be reliable enough for the single-calibration requirement of sensors used in NASA's bioreactors. The pH and pC02 sensors in the bundle are reliable and stable over the measurement period, and can be used without recalibration to measure cell cultures in rn.jcrogravity biotechnology experiments. Future work will test additional Paratrend sensors to provide statistical assessment of sensor performance.

Pappas, D.↗

Modeling Redshift-space Clustering with Abundance Matching

Abstract We explore the degrees of freedom required to jointly fit projected and redshift-space clustering of galaxies selected in three bins of stellar mass from the Sloan Digital Sky Survey Main Galaxy Sample (SDSS MGS) using a subhalo abundance matching (SHAM) model. We employ emulators for relevant clustering statistics in order to facilitate our analysis, leading to large speed gains with minimal loss of accuracy. We are able to simultaneously fit the projected and redshift-space clustering of the two most massive galaxy samples that we consider with just two free parameters: scatter in stellar mass at fixed SHAM proxy, and the dependence of the SHAM proxy on dark matter halo concentration. We find some evidence for models that include velocity bias, but including orphan galaxies improves our fits to the lower-mass samples significantly. We also model the clustering signals of specific star formation rate (sSFR) selected samples using conditional abundance matching (CAM). We obtain acceptable fits to projected and redshift-space clustering as a function of sSFR and stellar mass using two CAM variants, although the fits are worse than for stellar-mass-selected samples alone. By incorporating nonunity correlations between the CAM proxy and sSFR, we are able to resolve previously identified discrepancies between CAM predictions and SDSS observations of the environmental dependence of quenching for isolated central galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Lens Model Accuracy in the Expected LSST Lensed AGN Sample

Strong gravitational lensing of active galactic nuclei (AGN) enables measurements of cosmological parameters through time-delay cosmography (TDC). With data from the upcoming LSST survey, we anticipate using a sample of O(1000) lensed AGN for TDC. To prepare for this dataset and enable this measurement, we construct and analyze a realistic mock sample of 1300 systems drawn from the OM10 (Oguri & Marshall 2010) catalog of simulated lenses with AGN sources at $z<3.1$ in order to test a key aspect of the analysis pipeline, that of the lens modeling. We realize the lenses as power law elliptical mass distributions and simulate 5-year LSST i-band coadd images. From every image, we infer the lens mass model parameters using neural posterior estimation (NPE). Focusing on the key model parameters, $θ_E$ (the Einstein Radius) and $γ_{lens}$ (the projected mass density profile slope), with consistent mass-light ellipticity correlations in test and training data, we recover $θ_E$ with less than 1% bias per lens, 6.5% precision per lens and $γ_{lens}$ with less than 3% bias per lens, 8% precision per lens. We find that lens light subtraction prior to modeling is only useful when applied to data sampled from the training prior. If emulated deconvolution is applied to the data prior to modeling, precision improves across all parameters by a factor of 2. Finally, we combine the inferred lens mass models using Bayesian Hierarchical Inference to recover the global properties of the lens sample with less than 1% bias.

Venkatraman, Padmavathi [Illinois U., Urbana; KIPA↗

Decision Making In A High-Tech World: Automation Bias and Countermeasures

Automated decision aids and decision support systems have become essential tools in many high-tech environments. In aviation, for example, flight management systems computers not only fly the aircraft, but also calculate fuel efficient paths, detect and diagnose system malfunctions and abnormalities, and recommend or carry out decisions. Air Traffic Controllers will soon be utilizing decision support tools to help them predict and detect potential conflicts and to generate clearances. Other fields as disparate as nuclear power plants and medical diagnostics are similarly becoming more and more automated. Ideally, the combination of human decision maker and automated decision aid should result in a high-performing team, maximizing the advantages of additional cognitive and observational power in the decision-making process. In reality, however, the presence of these aids often short-circuits the way that even very experienced decision makers have traditionally handled tasks and made decisions, and introduces opportunities for new decision heuristics and biases. Results of recent research investigating the use of automated aids have indicated the presence of automation bias, that is, errors made when decision makers rely on automated cues as a heuristic replacement for vigilant information seeking and processing. Automation commission errors, i.e., errors made when decision makers inappropriately follow an automated directive, or automation omission errors, i.e., errors made when humans fail to take action or notice a problem because an automated aid fails to inform them, can result from this tendency. Evidence of the tendency to make automation-related omission and commission errors has been found in pilot self reports, in studies using pilots in flight simulations, and in non-flight decision making contexts with student samples. Considerable research has found that increasing social accountability can successfully ameliorate a broad array of cognitive biases and resultant errors. To what extent these effects generalize to performance situations is not yet empirically established. The two studies to be presented represent concurrent efforts, with student and professional pilot samples, to determine the effects of accountability pressures on automation bias and on the verification of the accurate functioning of automated aids. Students (Experiment 1) and commercial pilots (Experiment 2) performed simulated flight tasks using automated aids. In both studies, participants who perceived themselves as accountable for their strategies of interaction with the automation were significantly more likely to verify its correctness, and committed significantly fewer automation-related errors than those who did not report this perception.

Mosier, Kathleen L.↗

Driving and characterizing nucleation of urea and glycine polymorphs in water

Crystal nucleation is relevant across the domains of fundamental and applied sciences. However, in many cases, its mechanism remains unclear due to a lack of temporal or spatial resolution. To gain insights into the molecular details of nucleation, some form of molecular dynamics simulations is typically performed; these simulations, in turn, are limited by their ability to run long enough to sample the nucleation event thoroughly. To overcome the timescale limits in typical molecular dynamics simulations in a manner free of prior human bias, here, we employ the machine learning-augmented molecular dynamics framework “reweighted autoencoded variational Bayes for enhanced sampling (RAVE).” We study two molecular systems—urea and glycine—in explicit all-atom water, due to their enrichment in polymorphic structures and common utility in commercial applications. From our simulations, we observe multiple back-and-forth nucleation events of different polymorphs from homogeneous solution; from these trajectories, we calculate the relative ranking of finite-sized polymorph crystals embedded in solution, in terms of the free-energy difference between the finite-sized crystal polymorph and the original solution state. We further observe that the obtained reaction coordinates and transitions are highly nonclassical.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reducing model error using optimized galaxy selection: weak lensing cluster mass estimation

Galaxy clusters are one of the most powerful probes to study extensions of General Relativity and the Standard Cosmological Model. Upcoming surveys like the Vera Rubin Observatory’s Legacy Survey of Space and Time are expected to revolutionise the field, by enabling the analysis of cluster samples of unprecedented size and quality. To reach this era of high-precision cluster cosmology, the mitigation of sources of systematic error is crucial. A particularly important challenge is bias in cluster mass measurements induced by the mismodelling of photometric redshift estimates of source galaxies. This work proposes a method to optimise the source sample selection in cluster weak lensing analyses drawn from wide-field survey lensing catalogs to reduce the bias on reconstructed cluster masses. We use a combinatorial optimisation scheme and methods from variational inference to select galaxies in latent space to produce a probabilistic galaxy source sample catalog for highly accurate cluster mass estimation. We show that our method reduces the critical surface mass density Σ crit relative modelling bias on the 60-70% level, while maintaining up to 90% of galaxies. We highlight that our methodology has applications beyond cluster mass estimation as an approach to jointly combine galaxy selection and model inference under sources of systematics.

79 ASTRONOMY AND ASTROPHYSICS↗

The COS Legacy Archive Spectroscopy Survey (CLASSY) Treasury Atlas

Far-ultraviolet (FUV; ~1200–2000 Å) spectra are fundamental to our understanding of star-forming galaxies, providing a unique window on massive stellar populations, chemical evolution, feedback processes, and reionization. The launch of the James Webb Space Telescope will soon usher in a new era, pushing the UV spectroscopic frontier to higher redshifts than ever before; however, its success hinges on a comprehensive understanding of the massive star populations and gas conditions that power the observed UV spectral features. This requires a level of detail that is only possible with a combination of ample wavelength coverage, signal-to-noise, spectral-resolution, and sample diversity that has not yet been achieved by any FUV spectral database. We present the Cosmic Origins Spectrograph Legacy Spectroscopic Survey (CLASSY) treasury and its first high-level science product, the CLASSY atlas. CLASSY builds on the Hubble Space Telescope (HST) archive to construct the first high-quality (S/N 1500 Å ≳ 5/resel), high-resolution (R ~ 15,000) FUV spectral database of 45 nearby (0.002 < z < 0.182) star-forming galaxies. The CLASSY atlas, available to the public via the CLASSY website, is the result of optimally extracting and coadding 170 archival+new spectra from 312 orbits of HST observations. The CLASSY sample covers a broad range of properties including stellar mass (6.2 < log M * (M ⊙ ) < 10.1), star formation rate (–2.0 < log SFR (M ⊙ yr –1 ) < +1.6), direct gas-phase metallicity (7.0 < 12+log(O/H) < 8.8), ionization (0.5 < O 32 < 38.0), reddening (0.02 < E(B – V) < 0.67), and nebular density (10 < n e (cm –3 ) < 1120). CLASSY is biased to UV-bright star-forming galaxies, resulting in a sample that is consistent with the z ~ 0 mass–metallicity relationship, but is offset to higher star formation rates by roughly 2 dex, similar to z ≳ 2 galaxies. This unique set of properties makes the CLASSY atlas the benchmark training set for star-forming galaxies across cosmic time.

79 ASTRONOMY AND ASTROPHYSICS↗

Galaxy Clustering with LSST: Effects of Number Count Bias from Blending

The Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) will survey the southern sky to create the largest galaxy catalog to date, and its statistical power demands an improved understanding of systematic effects such as source overlaps, also known as blending. In this work we study how blending introduces a bias in the number counts of galaxies (instead of the flux and colors), and how it propagates into galaxy clustering statistics. We use the 300 deg 2 DC2 image simulation and its resulting galaxy catalog (LSST Dark Energy Science Collaboration et al. 2021) to carry out this study. We find that, for a LSST Year 1 (Y1)-like cosmological analyses, the number count bias due to blending leads to small but statistically significant differences in mean redshift measurements when comparing an observed sample to an unblended calibration sample. In the two-point correlation function, blending causes differences greater than 3σ on scales below approximately 10', but large scales are unaffected. We fit Ω m and linear galaxy bias in a Bayesian cosmological analysis and find that the recovered parameters from this limited area sample, with the LSST Y1 scale cuts, are largely unaffected by blending. Our main results hold when considering photometric redshift and a LSST Year 5 (Y5)-like sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Exchange Bias Between van der Waals Materials: Tilted Magnetic States and Field-Free Spin–Orbit-Torque Switching

Magnetic van der Waals heterostructures provide a unique platform to study magnetism and spintronics device concepts in the 2D limit. Here, studies of exchange bias from the van der Waals antiferromagnet CrSBr acting on the van der Waals ferromagnet Fe3GeTe2 (FGT) are reported. Additionally, the orientation of the exchange bias is along the in-plane easy axis of CrSBr, perpendicular to the out-of-plane anisotropy of the FGT, inducing a strongly tilted magnetic configuration in the FGT. Furthermore, the in-plane exchange bias provides sufficient symmetry breaking to allow deterministic spin–orbit torque switching of the FGT in CrSBr/FGT/Pt samples at zero applied magnetic field. A minimum thickness of the CrSBr of >10 nm is needed to provide a non-zero exchange bias at 30 K.

36 MATERIALS SCIENCE↗