Search NASA⌕ Search

SEARCH · Search NASA

Results for “scan pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Structure, Morphology, Cation Distribution and Magnetic Properties of Cr{sup 3+}-Substituted CoFe{sub 2}O{sub 4} Nanoparticles

The present investigations deal with the effect of trivalent chromium ions (Cr{sup 3+}) on structural and magnetic properties of nanocrystalline cobalt ferrite (CoFe{sub 2}O{sub 4}) nanoparticles. The samples of CoCr{sub x}Fe{sub 2−x}O{sub 4} (where x = 0.0 to 1.0 in step of 0.2) were successfully synthesized by citric acid-assisted sol-gel auto combustion method. Further, the prepared samples were characterized by x-ray diffraction (XRD), scanning electron microscopy (SEM), infrared spectroscopy (IR) and pulsed field hysteresis loop technique for structural, morphological and magnetic properties analysis, respectively. XRD patterns showed the formation of single-phase cubic spinel structure with broad Bragg’s peak for all the samples. The value of lattice parameter was found to be decreased with chromium substitution x. Cation distribution studies revealed that Co{sup 2+} and Fe{sup 3+} occupied both A and B sites, whereas Cr{sup 3+} ions occupied only B site. SEM analysis of the prepared samples confirmed the nanocrystalline nature of the material. The two absorption bands belonging to spinel structure were observed in IR spectra. Saturation magnetization (M{sub S}), remanence magnetization (M{sub r}) and coercivity (H{sub C}) was found to be decreased with increase in chromium substitution x.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A simple facile approach to large scale synthesis of high specific surface area silicon nanoparticles

An inexpensive, facile, and high throughput synthesis of silicon nanoparticles was achieved by the mechano-chemical reduction reaction of magnesium silicide (Mg{sub 2}Si) and silicon monoxide (SiO) using a high energy mechanical milling (HEMM) technique followed by acid leaching. Characterization of the resultant product using X-Ray diffraction, Raman spectroscopy, scanning electron microscopy (SEM), transmission electron microscopy (TEM) and surface area analyses was performed at various stages of the synthesis process. XRD patterns show that the final product formed is single phase silicon and the nanocrystalline nature was confirmed by the shifted transverse optical (TO) band, characteristic of nc-Si determined by Raman analysis. SEM and TEM shows the presence of particles of different sizes in the range of few nanometers to agglomerates of few microns which is consistent with products obtained from mechanical milling. BET measurements show a very high specific surface area (SSA) of ∼190 m{sup 2}/g obtained due to acid leaching which is also validated by the porous nature of the particles confirmed by the SEM images. - Graphical abstract: Schematic showing the large scale production of nanosized silicon and BET surface area of the product formed at various stages.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tilted fluctuation electron microscopy

Fluctuation electron microscopy (FEM) is a scanning nanodiffraction-based method that offers a unique approach to characterizing nanometer-scale medium-range order (MRO) in disordered materials. In addition to determining the degree of MRO, careful analysis of scanning nanodiffraction data can also be used to determine strain in thin film amorphous samples. We applied FEM to characterize the strain and MRO of magnetron sputtered amorphous tantalum (a-Ta) thin films over a range of tilt angles from 0° to 45° in order to measure any deviations between the in-plane and out-of-plane strain and MRO. We validate our approach using electron diffraction simulations of FEM experiments for a-Ta. We measure anisotropic strain in the simulated a-Ta diffraction patterns and find that the experimental a-Ta is isotropically strained within the accuracy of our method. Our approach provides a workflow for acquiring tilted scanning nanodiffraction data, determining the relative strain and ordering as a function of in- A nd out-of-plane directions, and removing any artifacts induced in FEM data due to strain. We also describe some limitations of the tilted FEM method when applied to thin films with very low strains.

36 MATERIALS SCIENCE↗

FeCo Nanorods Preparation Using New Chemical Synthesis

The as-prepared and annealed iron/cobalt (FeCo) magnetic nanoparticles (NPs) were obtained using a simple method by iron chloride hexahydrate (FeCl{sub 3}.6H{sub 2}O) and cobalt chloride hexahydrate (CoCl{sub 3}.6H{sub 2}O) as precursors and sodium borohydride (NaBH{sub 4}) agent. The samples were characterized by high-resolution transmission electron microscopy (HRTEM), field effect scanning electron microscopy (FESEM), x-ray diffraction (XRD), electron-dispersive spectroscopy (EDS), and Fourier transform infrared spectroscopy (FTIR). The XRD patterns of FeCo samples showed the body center cubic (bcc) structure with a lattice constant of 2.70 Å. The SEM images showed that the particle size of the as-prepared sample was around 15 nm and the annealed sample was around 35 nm in diameter at 500 {sup ∘}C. It was found that by increasing annealing temperature, the size of the FeCo NPs increased to 60 nm at 1100 {sup ∘}C. TEM studies showed the rod-like particles for annealed sample. The sharp peaks in FTIR spectrum determined the element of FeCo NPs. EDS shows peaks of iron and cobalt with impurities in prepared samples. The result of magnetic measurements showed a good coercive field and saturation magnetization around 1158 Oe and 22 emu g{sup − 1}, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural, thermal and electrical characterizations of multiwalled carbon nanotubes and polyaniline composite

The undoped and doped composite of MWNTs (Multiwalled Carbon Nanotubes) with PANI (/Polyaniline) was prepared by chemical oxidative polymerization. The MWNTs/PANI composites have been characterized by using various techniques like Thermogravometric Analysis (TGA), Fourier transform infrared (FT-IR) spectrometer and Field emission scanning electron microscope (FE-SEM) and conductivity measurement by using two probe method. TGA results has shown that thermal stability followed the pattern undoped MWNTs/PANI composite < doped MWNTs/PANI composite. FE-SEM micrographs demonstrated the morphological changes on the surface of MWNTs as a result of composite formation. Fourier transformed infrared (FT-IR) spectra ascertained the formation of the composite. Study of electrical characteristics demonstrated that the doped MWNTs/PANI composite (1.2 × 10{sup 1} Scm{sup −1}) have better conductivity than the undoped MWNTs/PANI composite (10{sup −4} Scm{sup −1}). These CNTs based polymeric composites are of great importance in developing new nano-scale devices for future chemical, mechanical and electronic applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A clip-based protocol for breast boost radiotherapy provides clear target visualisation and demonstrates significant volume reduction over time

The clinical target volume (CTV) for early stage breast cancer is difficult to clearly identify on planning computed tomography (CT) scans. Surgical clips inserted around the tumour bed should help to identify the CTV, particularly if the seroma has been reabsorbed, and enable tracking of CTV changes over time. A surgical clip-based CTV delineation protocol was introduced. CTV visibility and its post-operative shrinkage pattern were assessed. The subjects were 27 early stage breast cancer patients receiving post-operative radiotherapy alone and 15 receiving post-operative chemotherapy followed by radiotherapy. The radiotherapy alone (RT/alone) group received a CT scan at median 25 days post-operatively (CT1rt) and another at 40 Gy, median 68 days (CT2rt). The chemotherapy/RT group (chemo/RT) received a CT scan at median 18 days post-operatively (CT1ch), a planning CT scan at median 126 days (CT2ch), and another at 40 Gy (CT3ch). There was no significant difference (P = 0.08) between the initial mean CTV for each cohort. The RT/alone cohort showed significant CTV volume reduction of 38.4% (P = 0.01) at 40 Gy. The Chemo/RT cohort had significantly reduced volumes between CT1ch: median 54 cm{sup 3} (4–118) and CT2ch: median 16 cm{sup 3}, (2–99), (P = 0.01), but no significant volume reduction thereafter. Surgical clips enable localisation of the post-surgical seroma for radiotherapy targeting. Most seroma shrinkage occurs early, enabling CT treatment planning to take place at 7 weeks, which is within the 9 weeks recommended to limit disease recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deposition of Pd–Ag thin film membranes on ceramic supports for hydrogen purification/separation

Highlights: • Thin film Pd–Ag membranes have been produced for hydrogen selectivity. • Magnetron sputtering yields Pd–Ag compact films for atomic H diffusion. • The thin film Pd–Ag membranes yielded a selectivity of α (H{sub 2}/N{sub 2}) = 10. - Abstract: Pd–Ag based membranes supported on porous α-Al{sub 2}O{sub 3} (doped with yttria-stabilized zirconia) were studied for hydrogen selective separation. Magnetron sputtering technique was employed for the synthesis of thin film membranes. The hydrogen permeation flux is affected by the membrane columnar structure, which is formed during deposition. From scanning electron microscopy analysis, it was observed that different sputtering deposition pressures lead to distinct columnar structure growth. X-ray diffraction patterns provided evidence of a Pd–Ag solid solution with an average crystallite domain size of 21 nm, whose preferential growth can be altered by the deposition pressure. The gas-permeation results have shown that the Pd–Ag membrane supported on porous α-Al{sub 2}O{sub 3} is selective toward H{sub 2}. For optimized membrane synthesis conditions, the permeance toward N{sub 2} is 0.076 × 10{sup −6} mol m{sup −2} s{sup −1} Pa{sup −1} at room temperature, whereas for a pressure difference of 300 kPa the H{sub 2}-flux is of the order of ca. 0.21 mol m{sup −2} s{sup −1}, which corresponds to a permeance of 0.71 × 10{sup −6} mol m{sup −2} s{sup −1} Pa{sup −1}, yielding a selectivity of α (H{sub 2}/N{sub 2}) = 10. These findings suggest that the membrane has a reasonable capacity to selectively permeate this gas.

36 MATERIALS SCIENCE↗

SU-C-210-03: Impact of Breathing Irregularities On Gated Treatments

Purpose: To evaluate the effect of breathing irregularities on target location in gated treatments using amplitude and phase gating. Methods: 111 breathing patterns acquired using RPM system were categorized based on period and amplitude STD as regular (STD period ≤ 0.5 s, STD amplitude ≤ 1.5 mm), medium (0.5 s < STD period ≤ 1 s, 1.5 mm < STD amplitude ≤ 3 mm) and irregular (STD period > 1 s, STD amplitude > 3 mm). One pattern representative of the average defined population was selected per category and corresponding target motion reproduced using Quasar Respiratory Motion Phantom. Phantom in motion underwent 4D-CT scan with phase reconstruction. Gated window was defined at end of exhale and DRRs reconstructed in treatment planning at 40% (beam on) and 60% phase (beam off). Target location uncertainty was assessed by comparing gated kV triggered images continuously acquired at beam on/off on a True Beam 2.0 with corresponding DRRs. Results: Average target uncertainty with amplitude gating was in [0.4 – 1.9] mm range for the different scenarios with maximum STD of 1.2 mm for the irregular pattern. Average target uncertainty with phase gating was [1.1 – 2.2] mm for regular and medium patterns, while it increased to [3.6 – 9.6] mm for the irregular pattern. Live gated motion was stable with amplitude gating, while increasing with phase gating for the irregular pattern. Treatment duration range was [68 – 160] s with amplitude and [70 – 74] s with phase gating. Conclusion: Breathing irregularities were found to affect gated treatments only when using phase gating. For regular and medium patterns no significant difference was found between the two gating strategies. Amplitude gating ensured stable gated motion within the different patterns, thus reducing intra-fraction target location variability for the irregular pattern and resulting in longer treatment duration.

60 APPLIED LIFE SCIENCES↗

Epitaxial growth of monolayer PdTe 2 and patterned PtTe 2 by direct tellurization of Pd and Pt surfaces

Two-dimensional (2D) palladium ditelluride (PdTe 2 ) and platinum ditelluride (PtTe 2 ) are two Dirac semimetals, which have fascinating quantum properties such as superconductivity, magnetism and topological order and show the promising applications in future nanoelectronics and optoelectronics. However, the synthesis of PdTe 2 and PtTe 2 monolayers (MLs) is hindered by a strong interlayer coupling and orbital hybridization. Here, in this study, we demonstrate an efficient synthesis of PdTe 2 and PtTe 2 MLs Large-area and high quality MLs of PdTe 2 and patterned PtTe 2 were epitaxially grown on the Pd(111) and Pt(111) surfaces by direct telurization in ultra-high vacuum. This was confirmed by x-ray photoelectron spectroscopy, low energy electron diffraction and scanning tunnelling microscopy. PdTe 2 ML demonstrated high thermal stability showing no decomposition sign after annealing at 470 °C. A well-ordered (2 × 2) PtTe 2 structure with Kagome lattice was observed on Te/Pt(111) surface following annealing at 200 °C in UHV, where the (2 × 2) pattern was formed by Te atom vacancies. PtTe 2 multilayer film was prepared as well, and it demonstrated the excitation of the Dirac plasmons as measured by high-resolution electron energy loss spectroscopy. The direct tellurization offers the simple and reliable protocol for the preparation of the ML of PdTe 2 and patterned PtTe 2 , and this opens new opportunities for quantum phenomena research and for practical optoelectronics applications.

2D materials↗

Synthesis of BiSrCa(Y)CuO superconductor from the sol-gel method and the effect of Y substitution

Superconducting Bi{sub 2}Sr{sub 2}Ca{sub 1-x}Y{sub x}Cu{sub 2}O{sub 8} ceramics samples have been prepared by Sol-Gel methods using citrate process. The influences of the conditions of preparation of oxide powder compound on structural and superconducting properties have been investigated by X ray diffraction (XRD), Scanning Electron Microscopy (SEM) equipped with EDS. The critical transition temperatures Tc have been determined by resistivity versus temperature measurements. Cell parameters samples were calculated from XRD patterns. The polyacryl amide gel makes the citrate process easier, more rapid and affords the possibility of synthesis of high quality oxide powders.

36 MATERIALS SCIENCE↗

Phase‐Dependent Band Gap Engineering in Alloys of Metal‐Semiconductor Transition Metal Dichalcogenides

Abstract Bandgap engineering plays a critical role in optimizing the electrical, optical and (photo)‐electrochemical applications of semiconductors. Alloying has been a historically successful way of tuning bandgaps by making solid solutions of two isovalent semiconductors. In this work, a novel form of bandgap engineering involving alloying non‐isovalent cations in a 2D transition metal dichalcogenide (TMDC) is presented. By alloying semiconducting MoSe 2 with metallic NbSe 2 , two structural phases of Mo 0.5 Nb 0.5 Se 2 , the 1T and 2H phases, are produced each with emergent electronic structure. At room temperature, it is observed that the 1T and 2H phases are semiconducting and metallic, respectively. For the 1T structure, scanning tunneling microscopy/spectroscopy (STM/STS) is used to measure band gaps in the range of 0.42–0.58 at 77 K. Electron diffraction patterns of the 1T structure obtained at room temperature show the presence of a nearly commensurate charge density wave (NCCDW) phase with periodic lattice distortions that result in an uncommon 4 × 4 supercell, rotated approximately 4° from the lattice. Density‐functional‐theory calculations confirm that local distortions, such as those in a NCCDW, can open up a band gap in 1T ‐Mo 0.5 Nb 0.5 Se 2 , but not in the 2H phase. This work expands the boundaries of alloy‐based bandgap engineering by introducing a novel technique that facilitates CDW phases through alloying.

Wang, Shuxi↗

Laser Microdissection and Atmospheric Pressure Chemical Ionization Mass Spectrometry Coupled for Multimodal Imaging

This paper describes the coupling of ambient laser ablation surface sampling, accomplished using a laser capture microdissection system, with atmospheric pressure chemical ionization mass spectrometry for high spatial resolution multimodal imaging. A commercial laser capture microdissection system was placed in close proximity to a modified ion source of a mass spectrometer designed to allow for sampling of laser ablated material via a transfer tube directly into the ionization region. Rhodamine 6G dye of red sharpie ink in a laser etched pattern as well as cholesterol and phosphatidylcholine in a cerebellum mouse brain thin tissue section were identified and imaged from full scan mass spectra. A minimal spot diameter of 8 m was achieved using the 10X microscope cutting objective with a lateral oversampling pixel resolution of about 3.7 m. Distinguishing between features approximately 13 m apart in a cerebellum mouse brain thin tissue section was demonstrated in a multimodal fashion including co-registered optical and mass spectral chemical images.

atmospheric pressure chemical ionization (APCI)↗

Compatibility of $\theta_{13}$ and the Type I Seesaw Model with $A_4$ Symmetry

We derive formulae for neutrino masses and mixing angles in a type I seesaw framework with an underlying A (4) flavor symmetry. In particular, the Majorana neutrino mass matrix includes contributions from an A (4) triplet, 1, 1('), and 1(") flavon fields. Using these formulae, we constrain the general A (4) parameter space using the updated global fits on neutrino mixing angles and mass squared differences, including results from the Daya Bay and RENO experiments, and we find predictive relations among the mixing parameters for certain choices of the triplet vacuum expectation value. In the normal hierarchy case, sizable deviation from maximal atmospheric mixing is predicted, and such deviation is strongly correlated with the value of θ(13) in the range of ~ (8 -10)°. On the other hand, such deviation is negligible and insensitive to θ(13) in the inverted mass hierarchy case. We also show expectations for the Dirac CP phase resulting from the parameter scan. Future refined measurements of neutrino mixing angles will test these predicted correlations and potentially show evidence for particular triplet vev patterns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The effect of grain orientation on nanoindentation behavior of model austenitic alloy Fe-20Cr-25Ni

Instrumented nanoindentation was used in this paper to investigate the hardness, elastic modulus, and creep behavior of an austenitic Fe-20Cr-25Ni model alloy at room temperature, with the indented grain orientation being the variant. The samples indented close to the {111} surfaces exhibited the highest hardness and modulus. However, nanoindentation creep tests showed the greatest tendency for creep in the {111} indented samples, compared with the samples indented close to the {001} and {101} surfaces. Scanning electron microscopy and cross-sectional transmission electron microscopy revealed slip bands and dislocations in all samples. The slip band patterns on the indented surfaces were influenced by the grain orientations. Deformation twinning was observed only under the {001} indented surfaces. Finally, microstructural analysis and molecular dynamics modeling correlated the anisotropic nanoindentation-creep behavior with the different dislocation substructures formed during indentation, which resulted from the dislocation reactions of certain active slip systems that are determined by the indented grain orientations.

36 MATERIALS SCIENCE↗

Real-time microstructure imaging by Laue microdiffraction: A sample application in laser 3D printed Ni-based superalloys

Synchrotron-based Laue microdiffraction has been widely applied to characterize the local crystal structure, orientation, and defects of inhomogeneous polycrystalline solids by raster scanning them under a micro/nano focused polychromatic X-ray probe. In a typical experiment, a large number of Laue diffraction patterns are collected, requiring novel data reduction and analysis approaches, especially for researchers who do not have access to fast parallel computing capabilities. In this article, a novel approach is developed by plotting the distributions of the average recorded intensity and the average filtered intensity of the Laue patterns. Visualization of the characteristic microstructural features is realized in real time during data collection. As an example, this method is applied to image key features such as microcracks, carbides, heat affected zone, and dendrites in a laser assisted 3D printed Ni-based superalloy, at a speed much faster than data collection. Such analytical approach remains valid for a wide range of crystalline solids, and therefore extends the application range of the Laue microdiffraction technique to problems where real-time decision-making during experiment is crucial (for instance time-resolved non-reversible experiments).

36 MATERIALS SCIENCE↗

An instrument for 3D x-ray nano-imaging

We present an instrument dedicated to 3D scanning x-ray microscopy, allowing a sample to be precisely scanned through a beam while the angle of x-ray incidence can be changed. The position of the sample is controlled with respect to the beam-defining optics by laser interferometry. The instrument achieves a position stability better than 10 nm standard deviation. The instrument performance is assessed using scanning x-ray diffraction microscopy and we demonstrate a resolution of 18 nm in 2D imaging of a lithographic test pattern while the beam was defined by a pinhole of 3 {mu}m in diameter. In 3D on a test object of copper interconnects of a microprocessor, a resolution of 53 nm is achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanoselective area growth of GaN by metalorganic vapor phase epitaxy on 4H-SiC using epitaxial graphene as a mask

We report the growth of high-quality triangular GaN nanomesas, 30-nm thick, on the C-face of 4H-SiC using nanoselective area growth (NSAG) with patterned epitaxial graphene grown on SiC as an embedded mask. NSAG alleviates the problems of defects in heteroepitaxy, and the high mobility graphene film could readily provide the back low-dissipative electrode in GaN-based optoelectronic devices. A 5–8 graphene-layer film is first grown on the C-face of 4H-SiC by confinement-controlled sublimation of silicon carbide. Graphene is then patterned and arrays of 75-nm-wide openings are etched in graphene revealing the SiC substrate. A 30-nm-thick GaN is subsequently grown by metal organic vapor phase epitaxy. GaN nanomesas grow epitaxially with perfect selectivity on SiC, in the openings patterned through graphene. The up-or-down orientation of the mesas on SiC, their triangular faceting, and cross-sectional scanning transmission electron microscopy show that they are biphasic. The core is a zinc blende monocrystal surrounded with single-crystal wurtzite. The GaN crystalline nanomesas have no threading dislocations or V-pits. This NSAG process potentially leads to integration of high-quality III-nitrides on the wafer scalable epitaxial graphene/silicon carbide platform.

36 MATERIALS SCIENCE↗

Coherent elastographic tomography via speckle time multiplexing

A method is suggested for separating photons coming from different depths of tissue while externally stimulating tissue via infra-sonic vibration. The process of tomographic information extraction using the speckle time multiplexing approach is presented. Use is also made of a modulated laser combining a speckle-pattern tracking method for sensing surface tilting changes with an interferometer for sensing surface z-axis changes at the same scan time. (paper)

62 RADIOLOGY AND NUCLEAR MEDICINE↗