Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor technologies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

CMOS Active Pixel Sensors for Low Power, Highly Miniaturized Imaging Systems

The complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) technology has been developed over the past three years by NASA at the Jet Propulsion Laboratory, and has reached a level of performance comparable to CCDs with greatly increased functionality but at a very reduced power level.

CMOS complementary metal-oxide-semiconductor activ↗

Toward intelligent robot systems in aerospace

The incorporation of progressively more autonomous capabilities in spacecraft has been made possible by advancements in electronics technologies for sensors, communication, and computing equipment; as a result, space missions have been able to cope with ever-increasing complexity and data throughputs, as demonstrated by the six-order-of-magnitude increase in planetary mission data rates. In order to continue this pace of development into the Space Station era, NASA has accelerated its R&D in automation and robotics, with emphasis on autonomous, knowledge-based and expert system-employing technologies and AI.

Heer, Ewald↗

Lightning mapping sensor study

A technology assessment to determine how a world-wide, continuous measurement of lightning could be achieved from a geostationary platform is provided. Various approaches to the detector sensors are presented. It was first determined that any existing detector chips would require some degree of modification in order to meet the lightning mapper sensor requirements. The elements of the system were then analyzed, categorized, and graded for study emphasis. The recommended approach for the lightning mapper sensor is to develop a monolithic array in which each detector cell has circuitry that implements a two-step photon-collecting method for a very high dynamic range with good measurement accuracy. The efficiency of the array is compatible with the use of a conventional refractive optics design having an aperture in the neighborhood of 7 to 10 cm.

Norwood, V.↗

New instrumentation technologies for testing the bonding of sensors to solid materials

This report presents the results of a comprehensive research and development project that was conducted over a three-year period to develop new technologies for testing the attachment of sensors to solid materials for the following NASA applications: (1) testing the performance of composites that are used for the lining of solid rocket motor nozzles, (2) testing the bonding of surface-mounted platinum resistance thermometers that are used on fuel and oxidizer lines of the space shuttle to detect valve leaks by monitoring temperature, (3) testing the attachment of strain gages that are used in testing the performance of space shuttle main engines, and (4) testing the thermocouples that are used for determining the performance of blast tube liner material in solid rocket boosters.

Hashemian, H. M.↗

Microfluidic Mixing Technology for a Universal Health Sensor

A highly efficient means of microfluidic mixing has been created for use with the rHEALTH sensor an elliptical mixer and passive curvilinear mixing patterns. The rHEALTH sensor provides rapid, handheld, complete blood count, cell differential counts, electrolyte measurements, and other lab tests based on a reusable, flow-based microfluidic platform. These geometries allow for cleaning in a reusable manner, and also allow for complete mixing of fluid streams. The microfluidic mixing is performed by flowing two streams of fluid into an elliptical or curvilinear design that allows the combination of the flows into one channel. The mixing is accomplished by either chaotic advection around micro - fluidic loops. All components of the microfluidic chip are flow-through, meaning that cleaning solution can be introduced into the chip to flush out cells, plasma proteins, and dye. Tests were performed on multiple chip geometries to show that cleaning is efficient in any flowthrough design. The conclusion from these experiments is that the chip can indeed be flushed out with microliter volumes of solution and biological samples are cleaned readily from the chip with minimal effort. The technology can be applied in real-time health monitoring at patient s bedside or in a doctor s office, and real-time clinical intervention in acute situations. It also can be used for daily measurement of hematocrit for patients on anticoagulant drugs, or to detect acute myocardial damage outside a hospital.

Chan, Eugene Y.↗

Design study report. Volume 2: Electronic unit

The recording system discussed is required to record and reproduce wideband data from either of the two primary Earth Resources Technology Satellite sensors: Return Beam Vidicon (RBV) camera or Multi-Spectral Scanner (MSS). The camera input is an analog signal with a bandwidth from dc to 3.5 MHz; this signal is accommodated through FM recording techniques which provide a recorder signal-to-noise ratio in excess of 39 db, black-to-white signal/rms noise, over the specified bandwidth. The MSS provides, as initial output, 26 narrowband channels. These channels are multiplexed prior to transmission, or recording, into a single 15 Megabit/second digital data stream. Within the recorder, the 15 Megabit/second NRZL signal is processed through the same FM electronics as the RBV signal, but the basic FM standards are modified to provide an internal, 10.5 MHz baseland response with signal-to-noise ratio of about 25 db. Following FM demodulation, however, the MSS signal is digitally re-shaped and re-clocked so that good bit stability and signal-to-noise exist at the recorder output.

Source record↗

Guidance and control/ACEE

Active controls improve airplane performance by stabilizing its flight, reducing departures from stable flight, and alleviating loads imposed by external forces such as gusts, turbulence, or maneuvers. Some uses for active control systems, the design of redundant and reliable stability augmentation systems, digital fly-by-wire, and NASA assessments of the technology of sensors and actuators are discussed. A series of trade-off studies to better define optimum flight control systems, and research by drone and full-scale models are described.

Source record↗

1983 International Geoscience and Remote Sensing Symposium (IGARSS '83), San Francisco, CA, August 31-September 2, 1983, Digest. Volumes 1 & 2

Various papers on remote sensing are presented. The general topics addressed include: remote sensing of the biosphere, geophysical inversion, science and archaeology, image processing, sensing the atmosphere with microwaves, analysis of scattering for remote sensing, advanced sensors and technology, archaeology, data processing, fiber optics, Landsat-4 and TM. Also discussed are: remote sensing and microwave instrumentation, soil moisture and hydrology, measurement techniques for ocean surface waves, geological remote sensing, radar millimeter wave propagation through the atmosphere, and remote sensing in planetary science, geophysics, hydrology, oceanography, and surface vegetation.

Source record↗

Ground Operations

The contents include: 1) Integrated Space Transportation; 2) Fourth Generation Reusable Launch Vehicle (RLV) Research; 3) Ground Operations; 4) Ground Operations Technologies; 5) Sensors; and 6) Umbilicals. This paper is presented in viewgraph form.

Eastman, Randy↗

A High-Speed, Event-Driven, Active Pixel Sensor Readout for Photon-Counting Microchannel Plate Detectors

Silicon array readouts for microchannel plate intensifiers offer several attractive features. In this class of detector, the electron cloud output of the MCP intensifier is converted to visible light by a phosphor; that light is then fiber-optically coupled to the silicon array. In photon-counting mode, the resulting light splashes on the silicon array are recognized and centroided to fractional pixel accuracy by off-chip electronics. This process can result in very high (MCP-limited) spatial resolution for the readout while operating at a modest MCP gain (desirable for dynamic range and long term stability). The principal limitation of intensified CCD systems of this type is their severely limited local dynamic range, as accurate photon counting is achieved only if there are not overlapping event splashes within the frame time of the device. This problem can be ameliorated somewhat by processing events only in pre-selected windows of interest or by using an addressable charge injection device (CID) for the readout array. We are currently pursuing the development of an intriguing alternative readout concept based on using an event-driven CMOS Active Pixel Sensor. APS technology permits the incorporation of discriminator circuitry within each pixel. When coupled with suitable CMOS logic outside the array area, the discriminator circuitry can be used to trigger the readout of small sub-array windows only when and where an event splash has been detected, completely eliminating the local dynamic range problem, while achieving a high global count rate capability and maintaining high spatial resolution. We elaborate on this concept and present our progress toward implementing an event-driven APS readout.

Kimble, Randy A.↗

A High-Speed, Event-Driven, Active Pixel Sensor Readout for Photon-Counting Microchannel Plate Detectors

Silicon array readouts for microchannel plate intensifiers offer several attractive features. In this class of detector, the electron cloud output of the MCP intensifier is converted to visible light by a phosphor; that light is then fiber-optically coupled to the silicon array. In photon-counting mode, the resulting light splashes on the silicon array are recognized and centroided to fractional pixel accuracy by off-chip electronics. This process can result in very high (MCP-limited) spatial resolution while operating at a modest MCP gain (desirable for dynamic range and long term stability). The principal limitation of intensified CCD systems of this type is their severely limited local dynamic range, as accurate photon counting is achieved only if there are not overlapping event splashes within the frame time of the device. This problem can be ameliorated somewhat by processing events only in pre-selected windows of interest of by using an addressable charge injection device (CID) for the readout array. We are currently pursuing the development of an intriguing alternative readout concept based on using an event-driven CMOS Active Pixel Sensor. APS technology permits the incorporation of discriminator circuitry within each pixel. When coupled with suitable CMOS logic outside the array area, the discriminator circuitry can be used to trigger the readout of small sub-array windows only when and where an event splash has been detected, completely eliminating the local dynamic range problem, while achieving a high global count rate capability and maintaining high spatial resolution. We elaborate on this concept and present our progress toward implementing an event-driven APS readout.

Kimble, Randy A.↗

Performance Benefits for a Turboshaft Engine Using Nonlinear Engine Control Technology Investigated

The potential benefits of nonlinear engine control technology applied to a General Electric T700 helicopter engine were investigated. This technology is being developed by the U.S. Navy SPAWAR Systems Center for a variety of applications. When used as a means of active stability control, nonlinear engine control technology uses sensors and small amounts of injected air to allow compressors to operate with reduced stall margin, which can improve engine pressure ratio. The focus of this study was to determine the best achievable reduction in fuel consumption for the T700 turboshaft engine. A customer deck (computer code) was provided by General Electric to calculate the T700 engine performance, and the NASA Glenn Research Center used this code to perform the analysis. The results showed a 2- to 5-percent reduction in brake specific fuel consumption (BSFC) at the three Sikorsky H-60 helicopter operating points of cruise, loiter, and hover.

Jones, Scott M.↗

Hunting for mystery waves

Explore the source record for details and available documents.

uninhabited serial vehicles altitude record solar-↗

Satellites to the rescue

Explore the source record for details and available documents.

Helios ERAST UAV Environment Research Aircraft and↗

Simulation of the Impact of New Aircraft and Satellite-Based Ocean Surface Wind Measurements on H*Wind Analyses

Accurate observations of surface ocean vector winds (OVW) with high spatial and temporal resolution are required for understanding and predicting tropical cyclones. As NASA's QuikSCAT and Navy's WindSat operate beyond their design life, many members of the weather and climate science communities recognize the importance of developing new observational technologies and strategies to meet the essential need for OVW information to improve hurricane intensity and location forecasts. The Hurricane Imaging Radiometer (HIRAD) is an innovative technology development which offers new and unique remotely sensed satellite observations of both extreme oceanic wind events and strong precipitation. It is based on the airborne Stepped Frequency Microwave Radiometer (SFMR), which is the only proven remote sensing technique for observing tropical cyclone (TC) ocean surface wind speeds and rain rates. The proposed HIRAD instrument advances beyond the current nadir viewing SFMR to an equivalent wide-swath SFMR imager using passive microwave synthetic thinned aperture radiometer (STAR) technology. This sensor will operate over 4-7 GHz (C-band frequencies) where the required TC remote sensing physics has been validated by both SFMR and WindSat radiometers. The instrument is described in more detail in a paper by Jones et al. presented to the Tropical Meteorology Special Symposium at this AMS Annual Meeting. Simulated HIRAD passes through a simulation of hurricane Frances are being developed to demonstrate HIRAD estimation of surface wind speed over a wide swath in the presence of heavy rain. These are currently being used in "quick" OSSEs (Observing System Simulation Experiments) with H'Wind analyses as the discriminating tool. The H'Wind analysis, a product of the Hurricane Research Division of NOAA's Atlantic , Oceanographic and Meteorological Laboratory, brings together wind measurements from a variety of observation platforms into an objective analysis of the distribution of wind speeds in a tropical cyclone. This product is designed to improve understanding of the extent and strength of the wind field, and to improve the assessment of hurricane intensity. See http://www.aoml.noaa._ov/hrd/data sub/wind.html. Observations have been simulated from both aircraft altitudes and space. The simulated flight patterns for the aircraft platform cases have been designed to duplicate the timing and flight patterns used in routine NOAA and USAF hurricane surveillance flights, and the spaceborne case simulates a TRMM orbit and altitude.

Miller, TImothy L.↗