Search NASA⌕ Search

SEARCH · Search NASA

Results for “small sample size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

High Anion Conductivity and Low Water Uptake of Phosphonium Containing Diblock Copolymer Membranes

Poly[(styrene)- block -((2-acryloxy)ethyltributylphosphonium bromide)] diblock copolymers (STBP) were synthesized in two steps. First, reversible addition-fragmentation chain transfer polymerization was used to synthesize the diblock copolymer precursors poly[(styrene)- block -(bromoethyl acrylate)] (SBEA), followed by functionalization with tributylphosphine. Copolymers with overall molecular weights ranging from 31 to 87 kg/mol were synthesized. The volume fraction of the ion-containing monomers in the copolymers was fixed at about 0.57. Self-assembly of these copolymers into ordered morphologies with tunable domain sizes was demonstrated by small-angle X-ray scattering. The effect of morphology on water uptake and bromide ion conductivity was explored in samples equilibrated in liquid water. The use of the pendant tributylphosphonium cations, which have some hydrophobic character, results in low water uptake and high anionic conductivity. In conclusion, the conductivity increases with increasing domain size while water uptake is unaffected by domain size.

Cotanda, Pepa↗

Motion mitigation for lung cancer patients treated with active scanning proton therapy

Purpose: Motion interplay can affect the tumor dose in scanned proton beam therapy. This study assesses the ability of rescanning and gating to mitigate interplay effects during lung treatments. Methods: The treatments of five lung cancer patients [48 Gy(RBE)/4fx] with varying tumor size (21.1–82.3 cm{sup 3}) and motion amplitude (2.9–30.6 mm) were simulated employing 4D Monte Carlo. The authors investigated two spot sizes (σ ∼ 12 and ∼3 mm), three rescanning techniques (layered, volumetric, breath-sampled volumetric) and respiratory gating with a 30% duty cycle. Results: For 4/5 patients, layered rescanning 6/2 times (for the small/large spot size) maintains equivalent uniform dose within the target >98% for a single fraction. Breath sampling the timing of rescanning is ∼2 times more effective than the same number of continuous rescans. Volumetric rescanning is sensitive to synchronization effects, which was observed in 3/5 patients, though not for layered rescanning. For the large spot size, rescanning compared favorably with gating in terms of time requirements, i.e., 2x-rescanning is on average a factor ∼2.6 faster than gating for this scenario. For the small spot size however, 6x-rescanning takes on average 65% longer compared to gating. Rescanning has no effect on normal lung V{sub 20} and mean lung dose (MLD), though it reduces the maximum lung dose by on average 6.9 ± 2.4/16.7 ± 12.2 Gy(RBE) for the large and small spot sizes, respectively. Gating leads to a similar reduction in maximum dose and additionally reduces V{sub 20} and MLD. Breath-sampled rescanning is most successful in reducing the maximum dose to the normal lung. Conclusions: Both rescanning (2–6 times, depending on the beam size) as well as gating was able to mitigate interplay effects in the target for 4/5 patients studied. Layered rescanning is superior to volumetric rescanning, as the latter suffers from synchronization effects in 3/5 patients studied. Gating minimizes the irradiated volume of normal lung more efficiently, while breath-sampled rescanning is superior in reducing maximum doses to organs at risk.

60 APPLIED LIFE SCIENCES↗

Updimensioning strategy derived from synthetic equiaxed grain structures for approximating 3D grain size distributions from 2D visualizations with 1D parameters

We generated synthetic equiaxed grain structures using computer graphics software to explore the relationship between various grain size determination methods and true three-dimensional (3D) grain diameters. Mirroring grain measurement techniques, the synthetic 3D grain structures are imaged as 2D micrographs which are measured to yield 1D grain size parameters. Synthetic grain structures provide data at a mass scale and permit exploration of both polished and fractured surface micrographs, revealing one-to-one correspondence between exposed 2D grain cross-sections and individual 3D grains. Analysis of this correspondence yielded a procedure to approximate 3D equiaxed grain size and volume distributions based on the mode of the 2D fractograph grain size distribution. The 3D approximation procedure is shown to be less susceptible to different imaging conditions that affect small, undiscernible grains compared to the standard planimetric and linear intercept methods, which by design also tend to underestimate the 3D grain diameter. The procedure requires larger sample sizes to lower variance and a deeper analysis which could become more practical with machine learning (ML) models for grain boundary segmentation, which synthetic grain structures can help train. This work lays the foundation for analyzing other grain distributions such as columnar and composite grains in similar depth.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pulse compressor with aberration correction

In this SBIR project, Electron Optica, Inc. (EOI) is developing an electron mirror-based pulse compressor attachment to new and retrofitted dynamic transmission electron microscopes (DTEMs) and ultrafast electron diffraction (UED) cameras for improving the temporal resolution of these instruments from the characteristic range of a few picoseconds to a few nanoseconds and beyond, into the sub-100 femtosecond range. The improvement will enable electron microscopes and diffraction cameras to better resolve the dynamics of reactions in the areas of solid state physics, chemistry, and biology. EOI’s pulse compressor technology utilizes the combination of electron mirror optics and a magnetic beam separator to compress the electron pulse. The design exploits the symmetry inherent in reversing the electron trajectory in the mirror in order to compress the temporally broadened beam. This system also simultaneously corrects the chromatic and spherical aberration of the objective lens for improved spatial resolution. This correction will be found valuable as the source size is reduced with laser-triggered point source emitters. With such emitters, it might be possible to significantly reduce the illuminated area and carry out ultrafast diffraction experiments from small regions of the sample, e.g. from individual grains or nanoparticles. During phase I, EOI drafted a set of candidate pulse compressor architectures and evaluated the trade-offs between temporal resolution and electron bunch size to achieve the optimum design for two particular applications with market potential: increasing the temporal and spatial resolution of UEDs, and increasing the temporal and spatial resolution of DTEMs. Specialized software packages that have been developed by MEBS, Ltd. were used to calculate the electron optical properties of the key pulse compressor components: namely, the magnetic prism, the electron mirror, and the electron lenses. In the final step, these results were folded into a model describing the key electron-optical parameters of the complete pulse compressor. The simulations reveal that the mirror pulse compressor can reduce the temporal spread of UEDs and DTEMs to the sub-100 femtosecond level for practical electron bunch sizes. EOI’s pulse compressors can be designed and built to attach to different types of UEDs and DTEMs, thus making them suitable for enhancing the study of the structure, composition, and bonding states of new materials at ultrafast time scales to advance material science research in the field of nanotechnology as well as biomedical research.

47 OTHER INSTRUMENTATION↗

Mobility size and mass of nascent soot particles in a benchmark premixed ethylene flame

The burner stabilized stagnation flame technique coupled with micro-orifice probe sampling and mobility sizing has evolved into a useful tool for examining the evolution of the particle size distribution of nascent soot in laminar premixed flames. Several key aspects of this technique are examined through a multi-university collaborative study that involves both experimental measurement and computational modeling. Key issues examined include (a) data reproducibility and facility effects using four burners of different sizes and makers over three different facilities, (b) the mobility diameter and particle mass relationship, and (c) the degree to which the finite orifice flow rate affects the validity of the boundary condition in a pseudo one dimensional stagnation flow flame formulation. The results indicate that different burners across facilities yield nearly identical results after special attention is paid to a range of experimental details, including a proper selection of the sample dilution ratio and quantification of the experimental flame boundary conditions. The mobility size and mass relationship probed by tandem mass and mobility measurement shows that nascent soot with mobility diameter as small as 15 nm can deviate drastically from the spherical shape. Various non-spherical morphology models using a mass density value of 1.5 g/cm 3 can reconcile this discrepancy in nascent soot mass. Lastly, two-dimensional axisymmetric simulations of the experimental flame with and without the sample orifice flow reveal several problems of the pseudo one-dimensional stagnation flow flame approximation. The effect of the orifice flow on the flame and soot sampled, although small, is not negligible. Particular suggestions are provided as to how to treat the non-ideality of the experimental setup in experiment and model comparisons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Macroscopic Realization of the Weak Interaction

A.J.Leggett suggested in 1977 that a permanent electric dipole moment due to the parity-nonconserving electron-nucleon interaction, even though it is extremely small, could be measured in the superfluid He-3 B because the moment should be proportional to the size of the sample in this system. If this moment is observed, it will be the first example of a macroscopic realization of the weak interaction. In our planned experiments, a high electric field of up to 6 kV/cm is applied between two parallel electrodes in the He-3 sample. We expect to observe the NMR frequency of the lowest-lying spin-wave mode trapped by the liquid crystal-like texture of the B phase rotation axis in our geometry. The interaction of the electric field and the macroscopic permanent electric dipole moment, which is oriented along the rotation axis, will cause a small change in the texture and hence a small increase in the frequency of the spin wave mode. Besides the basic ideas, we present the purpose and the design of our first cell that is under construction.

Nishimori, Arito↗

Fast, Accurate, and Reliable Thermal Metrology to Assess the Thermal Resistivity on Small Samples of Thermal Insulation

Developing new insulation materials having a thermal resistivity greater than 69 m K/W (10 hr ft2 °F/Btu/inch) can be appealing for building envelope retrofit and construction of new buildings. Multiple institutions are involved in the development of innovative insulation materials with high thermal resistivity. However, these projects have struggled in the development of new materials due to the difficulty associated with the measurement of small sections of high thermal resistivity materials. As new materials are being developed, the size of each test specimen impacts the cost of development. Given the lack of a reliable method to measure the thermal resistivity on small samples of such materials, we evaluated experimental techniques that can be improved to satisfy the need for testing small sections of high thermal resistivity materials and developed standardized test methods to enable the rapid thermal evaluation of advanced insulation materials. This paper presents the study results and potential techniques for fast, accurate, and reliable effective thermal resistivity measurement on small samples of insulation materials.

Desjarlais, Andre Omer↗

A fast and sensitive size-exclusion chromatography method for plasma extracellular vesicle proteomic analysis

Extracellular vesicles (EVs) carry diverse biomolecules derived from their parental cells, making their components excellent biomarker candidates. However, purifying EVs is a major hurdle in biomarker discovery since current methods require large amounts of samples, are time-consuming and typically have poor reproducibility. Here we describe a simple, fast, and sensitive EV fractionation method using size exclusion chromatography (SEC) on a fast protein liquid chromatography (FPLC) system. Our method uses a Superose 6 Increase 5/150, which has a bed volume of 2.9 mL. The FPLC system and small column size enable reproducible separation of only 50 µL of human plasma in 15 min. To demonstrate the utility of our method, we used longitudinal samples from a group of individuals who underwent intense exercise. A total of 838 proteins were identified, of which, 261 were previously characterized as EV proteins, including classical markers, such as cluster of differentiation (CD)9 and CD81. Quantitative analysis showed low technical variability with correlation coefficients greater than 0.9 between replicates. The analysis captured differences in relevant EV proteins involved in response to physical activity. Our method enables fast and sensitive fractionation of plasma EVs with low variability, which will facilitate biomarker studies in large clinical cohorts.

59 BASIC BIOLOGICAL SCIENCES↗

Deposition of metallic gallium on re-crystallized ceramic material during focused ion beam milling

We report a new kind of artifact observed in the preparation of a TEM sample of zirconia by FIB, which consists in the deposition of metallic gallium nano-dots on the TEM sample surface. High resolution TEM images showed a microstructure of fine equiaxed grains of ∼ 5 nm, with some of them possessing two particular characteristics: high contrast and well-defined fast Fourier transform. These grains could not be identified as any phase of zirconia but it was possible to identify them as gallium crystals in the zone axis [110]. Based on HRTEM simulations, the possible orientations between zirconia substrate and deposited gallium are discussed in terms of lattice mismatch and oxygen affinity. - Highlights: • We show a new type of artifact induced during preparation of TEM samples by FIB. • Deposition of Ga occurs due to its high affinity for oxygen. • Materials with small grain size (∼ 5 nm) could promote Ga deposition. • Small grain size permits the elastic accommodation of deposited Ga.

36 MATERIALS SCIENCE↗

BioXTAS RAW 2 : new developments for a free open-source program for small-angle scattering data reduction and analysis

BioXTAS RAW is a free open-source program for reduction, analysis and modelling of biological small-angle scattering data. Here, the new developments in RAW version 2 are described. These include improved data reduction using pyFAI ; updated automated Guinier fitting and D max finding algorithms; automated series ( e.g. size-exclusion chromatography coupled small-angle X-ray scattering or SEC-SAXS) buffer- and sample-region finding algorithms; linear and integral baseline correction for series; deconvolution of series data using regularized alternating least squares ( REGALS ); creation of electron-density reconstructions using electron density via solution scattering ( DENSS ); a comparison window showing residuals, ratios and statistical comparisons between profiles; and generation of PDF reports with summary plots and tables for all analysis. Furthermore, there is now a RAW API, which can be used without the graphical user interface (GUI), providing full access to all of the functionality found in the GUI. In addition to these new capabilities, RAW has undergone significant technical updates, such as adding Python 3 compatibility, and has entirely new documentation available both online and in the program.

97 MATHEMATICS AND COMPUTING↗

The Energy Computation Paradox and ab initio Protein Folding

The routine prediction of three-dimensional protein structure from sequence remains a challenge in computational biochemistry. It has been intuited that calculated energies from physics-based scoring functions are able to distinguish native from nonnative folds based on previous performance with small proteins and that conformational sampling is the fundamental bottleneck to successful folding. We demonstrate that as protein size increases, errors in the computed energies become a significant problem. We show, by using error probability density functions, that physics-based scores contain significant systematic and random errors relative to accurate reference energies. These errors propagate throughout an entire protein and distort its energy landscape to such an extent that modern scoring functions should have little chance of success in finding the free energy minima of large proteins. Nonetheless, by understanding errors in physics-based score functions, they can be reduced in a post-hoc manner, improving accuracy in energy computation and fold discrimination.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CIS Project 22359, Final Technical Report. Discretized Posterior Approximation in High Dimensions

Our primary aim in this work is to understand how to efficiently obtain reliable uncertainty quantification in automatic learning algorithms with limited training datasets. Standard approaches rely on cross-validation to tune hyper parameters. Unfortunately, when our datasets are too small, holdout datasets become unreliable—albeit unbiased—measures of prediction quality due to the lack of adequate sample size. We should not place confidence in holdout estimators under conditions wherein the sample variance is both large and unknown. More poigniantly, our training experiments on limited data (Duersch and Catanach, 2021) show that even if we could improve estimator quality under these conditions, the typical training trajectory may never even encounter generalizable models.

97 MATHEMATICS AND COMPUTING↗

Structure and kinematics of the broad-line regions in active galaxies from IUE variability data

IUE archival data are used here to investigate the structure nad kinematics of the broad-line regions (BLRs) in nine AGN. It is found that the centroid of the line-continuum cross-correlation functions (CCFs) can be determined with reasonable reliability. The errors in BLR size estimates from CCFs for irregularly sampled light curves are fairly well understood. BLRs are found to have small luminosity-weighted radii, and lines of high ionization tend to be emitted closer to the central source than lines of low ionization, especially for low-luminosity objects. The motion of the gas is gravity-dominated with both pure inflow and pure outflow of high-velocity gas being excluded at a high confidence level for certain geometries.

Koratkar, Anuradha P.↗

Occultation studies of the solar system

Occultations of stars by planets, satellites, planetary ring systems, and asteroids offer opportunities to study the occulting bodies in ways not otherwise possible from the surface of the Earth. For example, one can detect even an extremely tenuous atmosphere and can measure the temperature and density profiles of the atmosphere in regions not ordinarily sampled by spacecraft. Occultations also permit direct measurement of the size and shape of solar system objects too small to be directly resolved by groundbased telescopes. The accuracy of such determinations is typically 1-2 percent and, moreover, is independent of the distance to the object. In this investigation, upcoming occultations through wide-ranging computer searches are identified, and accurate predictions for the more important events are provided. Selected occultations are observed with specially designed portable photometric equipment.

Millis, Robert L.↗

Cabin Crew Alertness and Performance During Long-Haul Flights

INTRODUCTION: -Sleep loss and circadian disruption pose a significant risk in aviation. -Previous literature has shown that inflight rest facilities influence alertness and performance among pilots, but few studies have evaluated cabin crew. -The aim of this research was to assess alertness and performance among cabin crew members sleeping in different rest locations during a long-haul out-and-back trip. METHODS: -Twenty-nine cabin crewmembers flew the same long-haul route (outbound and inbound). -Participants were randomly assigned to fly on an aircraft with a bunk in both directions or to fly an aircraft with a bunk in one direction and with a high comfort jump seat (HCJS) in the other direction. -Throughout the study they completed a Karolinska Sleepiness Scale (KSS) and a 5-minute Psychomotor Vigilance Task (PVT) at the beginning and at the end of each flight. RESULTS: -A series of mixed-effects models were performed to assess the changes in KSS and PVT when crewmembers slept in the bunk during both directions of flight (bunk-only) compared to when sleep was obtained in the HCJS during one direction and bunk in the other (bunk + HCJS). -There was no significant difference in KSS alertness between the two conditions. - There were no significant differences in PVT response speed or lapses between the two conditions. CONCLUSIONS: -Limitations: small number of participants. Our study stopped abruptly because of the COVID-19 pandemic which limited our sample size. -Further research is needed to understand how other factors such as duty start time and workload might influence the sleep of cabin crewmembers during long-haul flights.

long-haul↗

Further developments of capillary absorption spectrometers using small hollow-waveguide fibers

Our objective is to enhance quantification of stable carbon and oxygen isotope ratios to better than 1‰ relative isotope precision for sample sizes < 1 pico-mole. A newer variant Capillary Absorption Spectrometer (CAS) is described using a proprietary linear-taper hollow waveguide in conjunction with wavelength and frequency modulation techniques of tunable laser absorption spectrometry. Previous work used circular capillaries with uniform 1 mm ID to measure 13C/12C ratios with ≥ 20 pico-mole samples to ≤ 10 ppm (1‰ precision against standards) [1]. While performing fairly well, it generated residual modal noise due to multipath propagation in the hollow-waveguides (HWGs). This system has been utilized with laser ablation-catalytic combustion techniques to analyze small resolution (~ 25 μm spot diameter) laser ablation events on solids. Using smaller ID capillary waveguides could improve detection limits and spatial resolutions. Reducing an IR compatible hollow waveguide’s inner diameter (ID) to < 300 μm, reduces modal noise significantly for mid-IR operation, but feedback noise with high gain semiconductor lasers can become problematic. A proprietary linear-taper small waveguide (mean ID = 0.35 mm, L = 1 m) was tested to understand whether modal noise and optical feedback effects could be simultaneously reduced. We see better mode filtering and, significant reductions of feedback noise under favorable coupling of a multi-spatial mode QC laser to the smaller ID of the linear-tapered HWG. We demonstrate that better modal coupling operation is consistent with Liouville’s theorem, where greater suppression of feedback from spurious scatter within the HWG occurs by injecting the laser into the smaller ID port. Our progress on developing lighter weight, potentially fieldable alternatives to Isotope Ratio Mass Spectrometers (IRMS) with a small volume (≤ 0.1 cm3) CAS system will be discussed and compared to other competitive systems.

Kelly, James F.↗

The population of tiny near-Earth objects observed by NEOWISE

Only a very small fraction of the asteroid population at size scales comparable to the object that exploded over Chelyabinsk, Russia has been discovered to date, and physical properties are poorly characterized. We present previously unreported detections of 105 close approaching near-Earth objects (NEOs) by the Wide-field Infrared Survey Explorer (WISE) mission's NEOWISE project. These infrared observations constrain physical properties such as diameter and albedo for these objects, many of which are found to be smaller than 100 m. Because these objects are intrinsically faint, they were detected by WISE during very close approaches to the Earth, often at large apparent on-sky velocities. We observe a trend of increasing albedo with decreasing size, but as this sample of NEOs was discovered by visible light surveys, it is likely that selection biases against finding small, dark NEOs influence this finding.

79 ASTRONOMY AND ASTROPHYSICS↗

Imprecise global sensitivity analysis using bayesian multimodel inference and importance sampling

Global Sensitivity Analysis (GSA) aims to understand the relative importance of uncertain input variables to model response. Conventional GSA involves calculating sensitivity (Sobol’) indices for a model with known model parameter distributions. However, model parameters are affected by aleatory and epistemic uncertainty, with the latter often caused by lack of data. In this paper, we propose a new framework to quantify uncertainty in probability model-form and model parameters resulting from small datasets and integrate these uncertainties into Sobol’ index estimates. First, the process establishes, through Bayesian multimodel inference, a set of candidate probability models and their associated probabilities. Imprecise Sobol’ indices are calculated from these probability models using an importance sampling reweighting approach. This results in probabilistic Sobol’ indices, whose distribution characterizes uncertainty in the sensitivity resulting from small dataset size. The imprecise Sobol’ indices thus provide a measure of confidence in the sensitivity estimate and, moreover, can be used to inform data collection efforts targeted to minimize the impact of uncertainties. Through an example studying the parameters of a Timoshenko beam, we show that these probabilistic Sobol’ indices converge to the true/deterministic Sobol’ indices as the dataset size increases and hence, distribution-form uncertainty reduces. The approach is then applied to assess the sensitivity of the out-of-plane properties of an E-glass fiber composite material to its constituent properties. This second example illustrates the approach for an important class of materials with wide-ranging applications when data may be lacking for some input parameters.

42 ENGINEERING↗