Search NASA⌕ Search

SEARCH · Search NASA

Results for “software security”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Federating Cyber and Physical Models for Event-Driven Situational Awareness

The purpose of this paper is to describe a novel method to improve electric power system monitoring and control software application interoperability. This method employs the concept of federation, which is defined as the use of existing models that represent aspects of a system in specific domains (such as physical and cyber security domains) and building interface to link all of domain models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operationalizing Synchrophasors for Enhanced Grid Reliability and Asset Utilization

The report discusses the development of production-grade synchrophasor software applications. The objective is to improve system reliability and asset utilization for offline as well as real-time considerations, as per the Department of Energy (DOE) guidelines specified by Funding Opportunity Announcement (FOA) DE-FOA-0001492. On the one hand, we have developed grid management applications on how to transform synchrophasor-based monitoring into operator guidance, and commercial grade tools addressing industry needs such as NERC Reliability Standards (MOD 26, MOD 27 and MOD 33). On the other hand, with the wide industrial adoption in mind, the developed applications have been fully discussed with utility partners and installed in the utility partners site including 6 field tests. The Model Validation and Calibration software module has been integrated into GE’s PhasorAnalyticsTM. The first commercial contract has been signed even before the close date of this project. The Angle-based Grid Management (AGM), Fast Voltage Security Assessment (FastVSA), Enhanced Islanding Monitoring(EIM) and Enhanced Disturbance Management (EDM) have been integrated into GE’s Grid Stability Assessment line of applications in e-terra Suite of EMS product.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity and Digital Components: Supply Chain Deep Dive Assessment

The report “America’s Strategy to Secure the Supply Chain for a Robust Clean Energy Transition” lays out the challenges and opportunities faced by the United States in the energy supply chain as well as the federal government plans to address these challenges and opportunities. It is accompanied by several issue-specific deep dive assessments, including this one, in response to Executive Order 14017 “America’s Supply Chains,” which directs the Secretary of Energy to submit a report on supply chains for the energy sector industrial base. The Executive Order is helping the federal government to build more secure and diverse U.S. supply chains, including energy supply chains. As the energy sector has become more globalized and increasingly complex, digitized, and even virtualized, its supply chain risk for digital components – the software, virtual platforms and services, and data – in energy systems has evolved and expanded. All digital components in U.S. energy sector systems are vulnerable and may be subject to cyber supply cha in risks stemming from a variety of threats, vulnerabilities, and impacts. This includes digital components in all systems within the ESIB, namely those systems operated by asset owners across different energy subsectors (e.g., electricity, oil and natural gas, and renewables) and the systems operated by a worldwide industrial complex with capabilities to perform research and development and design, produce, operate, and maintain energy sector systems, subsystems, components, or parts to meet U.S. energy requirements. Supply chain risks for digital components including software, virtual platforms and services, and data have grown in recent years as increasingly sophisticated cyber adversaries have targeted exploiting vulnerabilities in these digital assets. Supply chain risks for digital components in energy sector systems will continue to evolve and likely increase as these systems are increasingly interconnected, digitized, and remotely operated.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Moore Machine Motion Controls Refurbishment Statement of Work and Specification

Diamond Turning Machines known as “Moore” machines are used in the production of Potassium diHydrogen Phosphate (KDP) optics required for the National Ignition Facility (NIF). These machines are owned by the Department of Energy, as provided by Lawrence Livermore National Security LLC (LLNS). Moore Machines 1 and 2 are located at the Gooch & Housego (G&H) facility in Highland Heights, OH. The existing Aerotech motion controllers, motor drivers/amplifiers, input/output (I/O) hardware, control computer, software user interface, human machine interface (HMI), cabling, and encoders are beyond service life and require replacement. This Statement of Work (SoW) defines the motion control system refurbishment requirements for the Moore diamond turning machines designated Moore 1 and Moore 2. The motion controls system design shall include a motion control computer, control software, motor drive amplifiers and controllers, linear scale encoders, rotary encoders, HMI, power distribution, emergency stop (E-Stop) and interlocks, cabling, switches, solenoids, transducers, sensors, actuators, ancillary system interfaces, and related components necessary for a complete machine tool control system. The Subcontractor shall include effort to standardize systems between the two machines if reasonably possible.

42 ENGINEERING↗

Vulnerabilities Under the Surface

This paper will describe a practical methodology for understanding the cyber risk of a digital asset. This research attempts to gain a greater understanding of the cyber risk posed by a hardware-based computer asset by considering it as a sum of its hardware and software based sub-components.

97 MATHEMATICS AND COMPUTING↗

Challenges and Strategies for Testing Automation Practices at Sandia National Laboratories

Sandia National Laboratories is a premier United States national security laboratory which develops science-based technologies in areas such as nuclear deterrence, energy production, and climate change. Computing plays a key role in its diverse missions, and within that environment, Research Software Engineers (RSEs) and other scientific software developers utilize testing automation to ensure quality and maintainability of their work. We conducted a Participatory Action Research study to explore the challenges and strategies for testing automation through the lens of academic literature. Through the experiences collected and comparison with open literature, we identify these challenges in testing automation and then present strategies for mitigation grounded in evidence-based practice and experience reports that other, similar institutions can assess for their automation needs.

97 MATHEMATICS AND COMPUTING↗

Cyber/Physical Security Vulnerability Assessment Integration

Securing high value and critical assets is one of the biggest challenges facing this nation and others around the world. In modern integrated systems, there are four potential modes of attack available to an adversary: • physical only attack, • cyber only attack, • physical-enabled cyber attack, • cyber-enabled physical attack. Blended attacks involve an adversary working in one domain to reduce system effectiveness in another domain. This enables the attacker to penetrate further into the overall layered defenses. Existing vulnerability assessment (VA) processes and software tools which predict facility vulnerabilities typically evaluate the physical and cyber domains separately. Vulnerabilities which result from the integration of cyber-physical control systems are not well characterized and are often overlooked by existing assessment approaches. In this paper, we modified modification of the timely detection methodology, used for decades in physical security VAs, to include cyber components. The Physical and Cyber Risk Analysis Tool (PACRAT) prototype illustrates an integrated vulnerability assessment that includes cyber-physical interdependencies. Information about facility layout, network topology, and emplaced safeguards is used to evaluate how well suited a facility is to detect, delay, and respond to attacks, to identify the pathways most vulnerable to attack, and to evaluate how often safeguards are compromised for a given threat or adversary type. We have tested the PACRAT prototype on critical infrastructure facilities and the results are promising. Future work includes extending the model to prescribe the recommended security improvements via an automated cost-benefit analysis.

MacDonald, Douglas G.↗

Gridtrust: Electricity Grid Root-of-Trust Decentralized Supply Chain Cyber-Security (Final Scientific/Technical Report)

GridTrust represents a departure from reliance on a single organization or a single person to multiple organizations and therefore multiple people across organizational structures. The motivating idea behind involving multiple organizations is the increase in security due to human factors. More specifically, the requirement that distinct people in different organizations sign off on a change or an update makes a cyberattack much less likely due to the inherent requirement that both organizations be penetrated and fooled. GridTrust focuses on the software update process as the primary exemplar for the research and development work. A novel hardware-based technology referred to as a Physical Unclonable Function (PUF) provides a microchip Root-of-Trust (RoT), i.e., a starting point for verifying that the hardware being communicated with is the hardware the control center believes the hardware to be. As a result, staff at power grid control centers can ensure the accurate and reliable identification of hardware devices from the outset. The GridTrust protocol introduces two key innovations, as detailed in this report. Firstly, the utilization of a PUF as a root-of-trust in the initial phase of a software or firmware update. Secondly, the application of multiple cryptographic signatures from two or more organizations to the update binary. These signatures are verified before implementing the update on a power grid device in the field. In terms of GridTrust hardware design, this report outlines two main components. The first is the GridTrust Native Device, integrating PUF technology intrinsically into the hardware device itself. The second is the GridTrust Interfacing Device, which incorporates PUF technology and multiple cryptographic signatures. These signatures are cross-checked within a separate hardware positioned between the power grid control center and the legacy power grid device, functioning as an intermediary. While the GridTrust Interfacing Device offers the advantage of being applicable to existing power grid equipment, it may have reduced security if the intermediary component is targeted. On the other hand, the GridTrust Native Device boasts increased security due to protocol integration within a unified form factor. The effectiveness of GridTrust technology has been extensively demonstrated, with multiple external red-team attackers unable to breach GridTrust's security measures. This was observed both in controlled laboratory settings during Phase 1 of the project and in real-world conditions within a City of Marietta substation during Phase 2 of the project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experiences with string matching on the Fermi Architecture

String matching is at the core of many real-world applications, such as security, bioinformatic, data mining. All these applications requires the ability to match always growing data sets against large dictionaries effectively, fastly and possibly in real time. Unfortunately, string matching is a computationally intensive procedure which poses significant challenges on current software and hardware implementations. Graphic Processing Units (GPU) have become an interesting target for such high-throughput applications, but the algorithms and the data structures need to be redesigned to be parallelized and adapted to the underlining hardware, coping with the limitations imposed by these architectures. In this paper we present an efficient implementation of the Aho-Corasick string matching algorithm on GPU, showing how we progressively redesigned the algorithm and the data structures to fit on the architecture. We then evaluate the implementation on single and multiple Tesla C2050 (T20 ``Fermi'' based) boards, comparing them to the previous Tesla C1060 (T10 based) solutions and equivalent multicore implementations on x86 CPUs. We discuss the various tradeoffs of the different architectures.

99 GENERAL AND MISCELLANEOUS↗

MARVEL 90% Final Design Report

This document provides documentation of the Microreactor Applications Research Validation and Evaluation Project’s (MARVEL) 90% Final Design, as required by U.S. Department of Energy (DOE) Standard-1189, “Integration of Safety into the Design Process." Per DOE-STD-1189-2016, the 90% Final Design documentation focuses on design completion, at a level capable of supporting procurement, construction, testing, and operation. At this phase, the design organization finalizes the hazards and accident analyses, Fire Hazard Analysis (FHA), security vulnerability assessments, and other supporting analyses for design completion. The objective of this report is to provide a high-level summary of the design thus far and provide references including, but not limited to, the following design deliverables: • Complete final drawings, specifications and commercial grade dedications that may be released for bid and/or construction. • Clearly defined testing plans for the safety and functionality of all subsystems. • Quality Assurance Program for Design, Testing and Procurement. • Software Quality Assurance Plan. • Code of Record (COR), applicable design requirements including codes and standards. • Final design that meets all the requirements stipulated in the COR. • Final design review, consisting of final validation of comment resolution from previous reviews, and a review of any additional developments since the last review. • Updated Safety Design Strategy. • Hazard Analysis. • Fire Hazard Analysis. • Accident analysis. • Security vulnerability assessment. • Current and detailed cost estimate. • Current construction schedule, and • Risk & Opportunities Assessment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Authentication of smart grid communications using quantum key distribution

Smart grid solutions enable utilities and customers to better monitor and control energy use via information and communications technology. Information technology is intended to improve the future electric grid’s reliability, efficiency, and sustainability by implementing advanced monitoring and control systems. However, leveraging modern communications systems also makes the grid vulnerable to cyberattacks. Here we report the first use of quantum key distribution (QKD) keys in the authentication of smart grid communications. In particular, we make such demonstration on a deployed electric utility fiber network. The developed method was prototyped in a software package to manage and utilize cryptographic keys to authenticate machine-to-machine communications used for supervisory control and data acquisition (SCADA). This demonstration showcases the feasibility of using QKD to improve the security of critical infrastructure, including future distributed energy resources (DERs), such as energy storage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Domain-Specific Language for High-Consequence Control Software

While most software development for control systems is directed at what the system is supposed to do (i.e., function), high-consequence controls must account for what the system is not supposed to do (i.e., safety, security and reliability requirements). A Domain Specific Language (DSL) for high-consequence digital controls is proposed. As with similar tools for the design of controls, the DSL will have plug-in modules for common controller functions. However, the DSL will also augment these modules with attendant "templates" that aid in the proof of safety, security and reliability requirements, not available in current tools. The object is to create a development methodology that makes construction of high-assurance control systems as easy as controls that are designed for function alone.

97 MATHEMATICS AND COMPUTING↗

Fast and robust strategies for large-scale mixed-integer SCOPF

This project develops scalable, computationally efficient algorithms to solve realistic large-scale power system optimization problems, including systems with more than 8,000 buses, as part of a larger series of competitions run by ARPA-E. These problems are critical because the secure and reliable operation of the power grid is becoming increasingly challenging, especially under conditions of increased uncertainty and variability. The economic feasibility of our methods is high, given that they are purely software-based solutions designed to operate power grids more efficiently. The technical effectiveness balances heuristics and approximations to provide a trade-off between speed and accuracy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

LEED: A Lightwave Energy-Efficient Datacenter

The Lightwave Energy-Efficient Datacenter (LEED) program is a disruptive “green-field” approach that provides a quantum leap in the energy efficiency of datacenters. LEED’s fundamental value proposition is that a novel and re-architected optical network—RotorNet— can deliver “more bandwidth per buck” as well as unique system-level attributes that significantly improve overall datacenter energy efficiency and performance. LEED has developed three system-level testbeds. The first testbed uses calibrated hardware and software power measurements to determine server energy efficiency as a function of network bandwidth and workload. These measurements have shown that increasing network communications bandwidth dramatically increases server energy efficiency providing a realistic path to the overall ENLITENED program goal of doubling the number of transactions per joule. The second testbed demonstrates key hardware: a prototype low-loss, high-port count optical “selector switch”. This switch was fabricated, racked, and tested. Measured switch characteristics include loss, bandwidth, crosstalk, switch time, system-level switch time (including the transceivers), and bit error rate. The third testbed demonstrates a fully working and manufactured pinwheel design which dramatically lowers the cost of design, while delivering high switch radix and low reconfiguration times. The LEED project has tied these three novel photonic switch prototypes together with production servers and software through the development of a novel FPGA-based NIC platform called Corundum. Corundum ensures that the packet-switched protocols supported by commodity operating systems and devices can interface with the Rotor switch design. The LEED group has used this combined hardware and software prototype to characterize applications running at a commercially relevant scale. The project has used a combination of enhanced optical modulation amplitude (OMA) modulators, broadband multiplexers and demultiplexers, avalanche photodiodes, and a novel burst-mode receivers to enable the insertion of LEED-developed optical switches without the need for expensive optical amplification. Our modeling has shown that measured LEED-developed device characteristics can achieve link characteristics of 2 pJ/bit including both transceivers and the Rotor switch. In summary, the LEED program has demonstrated a credible and practical path, through novel hardware and software, to realize the program objectives of ENLITENED. The net result will ensure that the United States maintains its strength in the crucial sector of Information Technology, which is vital to both our economic security and our national security.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Material Protection, Accounting, and Control Technologies (MPACT) Advanced Integration Roadmap

The development of sustainable advanced nuclear fuel cycles is a long-term goal of the Office of Nuclear Energy’s (DOE-NE) Fuel Cycle Technologies program. The Material Protection, Accounting, and Control Technologies (MPACT) campaign is supporting research and development (R&D) of advanced instrumentation, analysis tools, and integration methodologies to meet this goal (Miller, 2015). This advanced R&D is intended to facilitate safeguards and security by design of fuel cycle facilities. The lab-scale demonstration of a virtual facility, distributed test bed, that connects the individual tools being developed at National Laboratories and university research establishments, is a key program milestone for 2020. These tools will consist of instrumentation and devices as well as computer software for modeling, simulation and integration.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Geologic Framework Model for the Underground Nuclear Explosions Signatures Experiment P Tunnel Testbed, Aqueduct Mesa, Nevada National Security Site

Three-dimensional geologic framework model of the P-Tunnel Complex and vicinity has been constructed for the Underground Nuclear Explosion Signature Experiment to address anisotropy of physical properties within the experiment medium. The P-Tunnel geologic framework model was constructed using EarthVision geologic modeling software by Dynamic Graphics, Inc. The model area covers 4.36 square kilometers and includes the entire P-Tunnel Complex. The model extends vertically from 2,004 meters above mean sea level, the highest land surface elevation in the model area, to 1,000 meters above mean sea level. The P-Tunnel Complex lies at an elevation of approximately 1,676 meters above mean sea level. The model incorporates data and information from more than 55 years of geological and geophysical studies in the P-Tunnel region, including surface and subsurface geology maps, tunnel construction drawings, a digital elevation model of the topography, and orthophoto imagery. The model consists of thirteen layers, with each layer defining a distinct stratigraphic interval with similar physical properties. Because no faults with significant offset are present within the model area, no faults are incorporated directly into the model. Small-offset faults and other prominent fractures mapped during tunnel construction, however, were digitized and gridded to produce fault and fracture planes that can be viewed within the model. The model has been exported as simple ASCII text files that define the model layers as either two-dimensional surfaces representing the tops of each model layer, or as three-dimensional volumes. The model was also exported as binary-STL files for three-dimensional printing.

58 GEOSCIENCES↗

AmeriFlux FLUXNET-1F CA-SJ2 Saskatchewan - Western Boreal, Jack Pine forest harvested in 2002

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site CA-SJ2 Saskatchewan - Western Boreal, Jack Pine forest harvested in 2002. This is the FLUXNET version of the carbon flux data for the site CA-SJ2 Saskatchewan - Western Boreal, Jack Pine forest harvested in 2002 produced by applying the standard ONEFlux (1F) software. Site Description - 53.944737° N, 104.649340° W, BERMS flux and climate measurements to begin by Mar 2003

Barr, Alan [Global Institute for Water Security, U↗

Remote operation of the DIII-D National Fusion Facility

Abstract Full remote scientific operation of the DIII-D National Fusion Facility is now possible through significant advances in the computer science hardware and software infrastructure made over the last decade. Capabilities around information visualization, data movement, and communication have all been enhanced. The level of capability deployed to remotely operate DIII-D required an infrastructure advancement over what had previously been achieved in the fusion community. The large quantity of real-time data that is automatically displayed on DIII-D’s control room screens can now be visualized by remote participants via web-based applications. New audio/video solutions using the VoIP and instant messaging application Discord have been implemented to mimic the dynamic and ad-hoc scientific conversations that are critical in successfully operating an experimental campaign. Discord’s ability for a user to rapidly move between audio channels, text with images, and share screens is a significant enhancement over traditional videoconferencing tools. In addition, multiple combinations of broadcast audio are made available via a web-based application to allow remote participants to simultaneously listen to general announcements/sounds while conducting their own specific conversations. Secure methodologies have been put into place to allow remote control of hardware including DIII-D’s plasma control system application. Secure methods also included the ability of the on-site team to closely coordinate their work with remote team members which has been enhanced through extensions to the wireless network and the use of tablet computers for audio/video/screen sharing. However, no amount of software can fully replace the need for ‘hands on hardware.’ This infrastructure was severely stress tested during the COVID-19 pandemic where occupancy of the DIII-D control room was restricted. Operational efficiency during the pandemic, measured in discharges per hour, remained high (3.8 ± 0.8) compared to values obtained pre-pandemic (3.7 ± 0.8).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗