Search NASA⌕ Search

SEARCH · Search NASA

Results for “solid-state”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Grid oscillators

Loading a two-dimensional grid with active devices offers a means of combining the power of solid-state oscillators in the microwave and millimeter-wave range. The grid structure allows a large number of negative resistance devices to be combined. This approach is attractive because the active devices do not require an external locking signal, and the combining is done in free space. In addition, the loaded grid is a planar structure amenable to monolithic integration. Measurements on a 25-MESFET grid at 9.7 GHz show power-combining and frequency-locking without an external locking signal, with an ERP of 37 W. Experimental far-field patterns agree with theoretical results obtained using reciprocity.

Popovic, Zorana B.↗

Spectroscopic investigation of the Cr to Tm energy transfer in Yttrium Aluminum Garnet (YAG) crystals

New and interesting schemes have recently been considered for the efficient operation of solid-state ionic laser systems. Often the available data on these systems were obtained only because they seemed directly related to the laser performance and provide no insight into the physical processes. A more systematic approach is desirable, where more attention is devoted to the elementary basic processes and to the nature of the mechanisms at work. It is with this aim that we have undertaken the present study. Yttrium Aluminum Garnet (Y4Al5O12), called YAG, has two desirable properties as host for rare earth impurities: (1) trivalent rare earth ions can replace the yttrium without any charge compensation problem, and (2) YAG crystals have high cutoff energies. The results of measurements and calculations indicate that the Cr(3+) ion in YAG can be used to sensitize efficiently the Tm(3+) ion.

Dibartolo, B.↗

The determination of energy transfer rates in the Ho:Tm:Cr:YAG laser material

Energy transfer processes occurring between atomic, ionic, or molecular systems are very widespread in nature. The applications of such processes range form radiation physics and chemistry to biology. In the field of laser physics, energy transfer processes have been used to extend the lasing range, increase the output efficiency, and influence the spectral and temporal characteristics of the output pulses of energy transfer dye lasers or solid-state laser materials. Thus in the development of solid state lasers, it is important to investigate the basic energy transfer (ET) mechanisms and processes in order to gain detailed knowledge so that successful technical utilization can be achieved. The aim of the present research is to measure the ET rate from a given manifold associated with the chromium sensitizer atom to a given manifold in the holmium activator atom via the thulium transfer atom, in the Ho:Cr:YAG laser material.

Koker, Edmond B.↗

Development of a high-speed H-alpha camera system for the observation of rapid fluctuations in solar flares

A solid-state digital camera was developed for obtaining H alpha images of solar flares with 0.1 s time resolution. Beginning in the summer of 1988, this system will be operated in conjunction with SMM's hard X-ray burst spectrometer (HXRBS). Important electron time-of-flight effects that are crucial for determining the flare energy release processes should be detectable with these combined H alpha and hard X-ray observations. Charge-injection device (CID) cameras provide 128 x 128 pixel images simultaneously in the H alpha blue wing, line center, and red wing, or other wavelength of interest. The data recording system employs a microprocessor-controlled, electronic interface between each camera and a digital processor board that encodes the data into a serial bitstream for continuous recording by a standard video cassette recorder. Only a small fraction of the data will be permanently archived through utilization of a direct memory access interface onto a VAX-750 computer. In addition to correlations with hard X-ray data, observations from the high speed H alpha camera will also be correlated and optical and microwave data and data from future MAX 1991 campaigns. Whether the recorded optical flashes are simultaneous with X-ray peaks to within 0.1 s, are delayed by tenths of seconds or are even undetectable, the results will have implications on the validity of both thermal and nonthermal models of hard X-ray production.

Kiplinger, Alan L.↗

Infrared observations of small solar-system bodies

A major accomplishment during last year is the recongition of and modeling of the solid-state greenhouse effect for icy satellites. Recent observations of eclipse reappearances suggest that this effect may in fact be observed on Europa and Ganymede. Also the PI has obtained important new data on Europa and Enceladus. Evidence for the transient presence of a volatile, perhaps NH3, OH, on Europa has been obtained. Newly obtained spectra of Enceladus suggest that it does not at present have ammonia or methane in detectable quantities on its surface.

Brown, R. H.↗

Performance of efficient Q-switched diode-laser-pumped Nd:YAG and Ho:YLF lasers for space applications

Solid-state lasers pumped by continuous-wave diode lasers can be Q-switched to obtain high peak power output pulses. The dependence of laser-pulse energy, average output power, peak power, and pulse width on pulse-repetition frequency in Q-switched Nd:YAG and Ho:YLF lasers is determined and compared. At low pulse repetition rates, the much longer upper-stage lifetime in Ho:YLF gives a distinct advantage. At higher pulse rates, the overall laser efficiency and the stimulated emission cross section are more important parameters, leading to an advantage for Nd:YAG. The results are of significance for designing lasers for use in space optical communications and remote sensing systems.

Marshall, W. K.↗

Advanced altimetry

The radar altimeter being developed for the Ocean Topography Experiment (TOPEX) will have an inherent instrument precision of 2 to 3 cm. While some minor refinements may be possible in the future, major geophysical advances could be made if altimetric measurements over a wide swath of the Earth's surface were possible. The NASA Headquarters Oceanic Processes Branch is supporting a 3-year investigation of the technological issues inherent in the precision measurement of topography from spaceborne platforms at angles off-nadir. To explore the off-nadir measurement of topography, a flexible, airborne radar instrument system is being developed. Its hardware design is now complete, and it is made up of several subsystems. The antenna selected is a dielectric lens of .894 m diameter. The RF subsystem uses phase-locked oscillators, FET solid-state amplifiers, and times four frequency multipliers to develop a transmit signal at a frequency of 36.0 GHz and a local oscillator signal at a frequency of 35.4 GHz. Lecroy 6880 digitizers under computer control digitize the five receiver outputs. The digital subsystem consists of six single-board Heurikon processors. At this time, the instrument construction continues with final system integration planned for November 1988.

Parsons, C. L.↗

Advanced solidstate array spectroradiometer - Sensor and calibration improvements

The advanced solid-state array spectroradiometer (ASAS), an airborne imaging spectrometer with 30 spectral channels extending from 450-880 nm, is described. Modifications to the sensor mounting technique changed the ASAS from a fixed nadir viewing instrument to a sensor capable of multiple direction observations of surface bidirectional reflectance distribution functions. The system was flown on the NASA Ames C130 aircraft to obtain surface bidirectional reflectance measurements of vegetation; it demonstrated excellent reliability and radiometric stability.

Huegel, Frederick G.↗

Spectroscopic analysis of insulating crystal fibers

A new technique is described for investigating the optical properties of solid-state laser materials using single-crystal fibers grown by a laser-heated pedestal-growth technique. Single-crystal fiber samples can be prepared more rapidly and less expensively than crystals grown by more conventional methods; however, they are smaller and less uniform, making spectroscopic measurements difficult. A simple procedure for extracting the optical absorption and emission spectra of insulating crystal fibers is demonstrated with a titanium-doped sapphire fiber sample; results are comparable to those from Czochralski-grown material.

Buoncristiani, A. M.↗

Diffusional decay of striations

This paper investigates the amount of decay of growth striations in bulk crystals grown from melts and solutions, due to solid-state diffusion during the cooling of the crystal to room temperature. A model is developed based on the assumption of a sinusoidal variation in the solid composition at the interface of a semiinfinite ingot growing at constant velocity, and the damping behavior of this variation is followed as it moves away from the solid-liquid interface. Numerical results are presented showing that an increase in the diffusivity causes the striations to penetrate deeper into the solid and, consequently causes the distance for 99.9 percent decay to increase. Analytical results are also presented for the decay of striations in an isothermal ingot induced by a sinusoidal fluctuation in the rate of crystal growth.

Gray, R. T.↗

Evaluation of materials for tunable vibronic lasers

Three techniques (peak single-pass gain, fluoresence band narrowing, and lifetime shortening) for determining the effects of stimulated emission on the spectra of solid-state vibronic laser materials have been compared. The methods were employed to determine the pump energy density and population inversion at threshold, the stimulated emission cross section, and the gain coefficient for two potential vibronic laser materials. An effective shortening of the fluorescence lifetime is predicted at high excitation levels, with a distinct threshold where stimulated emission processes become important.

Kliewer, Michael L.↗

Monolithic watt-level millimeter-wave diode-grid frequency tripler array

In order to provide watt-level CW output power throughout the millimeter and submillimeter wave region, thousands of solid-state diodes have been monolithically integrated using a metal grid to produce a highly efficient frequency multiplier. Devices considered include GaAs Schottky diodes, thin MOS diodes, and GaAs Barrier-Intrinsic-N(+)diodes. The performance of the present compact low-cost device has been theoretically and experimentally validated.

Hwu, R. J.↗

Spectral transmissometer and radiometer - Design and initial results

A new solid-state spectral transmissometer and radiometer is described. The radiometer measures upwelling radiance, downwelling irradiance, and beam transmittance from 390 to 750 nm with channel widths of 2.35 nm. The spectrometer consists of a 256 element CCD linear array collecting light dispersed by a reflection grating in a modified Littrow configuration. The spectrometer is time and space-shared among the three signal types. The instrument has been deployed as a free-drifting buoy and in the profiling mode, with data stored internally on a magnetic bubble memory or sent up a conducting cable as desired. Power can be supplied either by a detachable external battery pack or through conducting cable. The instrument has been deployed in the oligotrophic North Pacific Central Gyre and in the eutrophic Straits of Juan de Fuca, and preliminary results for each region are discussed.

Carder, Kendall L.↗

Observation of an Excess Current Noise Resulting from Oxygen Absorption onto Iron Films

This paper reports on measurements that demonstrate that oxygen absorbed on clean polycrystalline Fe films can produce an excess current noise. The noise is indicative of dynamic processes occurring in the surface region of the film. We propose that the noise results from the dynamics of a reversible reaction between absorbed states. The measurements are accurately modeled with a single correlation time implying that surface heterogeneity is not important to the reaction. In addition to offering promise for future states of solid-state surface reactions, these measurements also have implications for the origin of 1/f current noise in conductors.

Shanabarger, M. R.↗

Pressure Measurement

Pressure Systems, Inc.'s DPT 6400 is a system designed to increase productivity in industrial processes where there is a need for making multiple pressure measurements quickly and with high accuracy. It is applicable in controlling industrial processes in plants that are being upgraded to automated status. In order to automate such plants the pressures at the many loops must be measured, converted to digital information and transmitted to the plant's process control computer. The DPT 6400 serves that function. By employing solid-state pressure sensing transducers whose errors are automatically corrected by a microprocessor, it is capable of highly accurate pressure measurements. Basic DPT 6400 has 64 channels, but the system can be expanded to 256 channels by the addition of "slave" units.

Source record↗

Emergency/Night Lightning

UDEC's highly efficient lighting system is finding wide acceptance among industrial and commercial firms as an energy savings means of providing emergency and night lighting. Originating from Skylab, the system consists of small high frequency fluorescent light fixtures powered by solar cells. Advantages of UDEC's lighting system stem from high reliability and high light output with very low energy drain. Principal components of system are long life fluorescent lamps operated by electronic circuitry, a sealed gelatine cell battery that needs no maintenance for eight years and a solid-state automatic battery charger. Installation of UDEC lighting in a company's six-and-a-half acre warehouse office cut the annual night lighting electric bill from $8,000 a year to $300 per year.

Source record↗

Emergency Lighting

A lighting system originally developed for NASA's Apollo and Skylab manned spacecraft resulted in a industrial spinoff and creation of a whole new company to produce and market the product line. The company is UDEC Corp., Waltham, Mass. UDEC's "Multi-Mode" electronic lighting systems are designed for plant emergency and supplemental use, such as night lighting, "always-on" stairwell lights and illuminated exit signs. Their advantages stem from the qualities demanded for spacecraft installation: extremely high fight output with very low energy drain, compactness, light weight, and high reliability. The Multi-Mode system includes long-life fluorescent lamps operated by electronic circuitry, a sealed battery that needs no maintenance for 10 years, and a solid-state battery charger. A typical emergency installation consists of a master module with battery and an eight watt lamp, together with four remote "Satellight" modules powered by the master's battery. As a night lighting system for maintenance or I security, UDEC fixtures can bypass the battery and 1 operate on normal current at a fraction of the energy 1 demand of conventional night lighting. Industrial customers have realized savings of better than ninety percent with UDEC night lights. UDEC started as a basement industry in 1972 but the company has already sold more than 1,000 lighting systems to building operators.

Source record↗

Breadboard Facility

In the sixties, Chrysler was NASA's prime contractor for the Saturn I and IB test launch vehicles. The company installed and operated at Huntsville what was known as the Saturn I/IB Development Breadboard Facility. "Breadboard," means an array of electrical and electronic equipment for performing a variety of development and test functions. This work gave Chrysler a broad capability in computerized testing to assure quality control in development of solid-state electronic systems. Today that division is manufacturing many products not destined for NASA, most of them being associated with the company's automotive line. A major project is production and quality-control testing of the "lean-burn" engine, one that has a built-in Computer to control emission timing, and allow the engine to run on a leaner mixture of fuel and air. Other environment-related products include vehicle emission analyzers. The newest of the line is an accurate, portable solid state instrument for testing auto exhaust gases. The exhaust analyzers, now being produced for company dealers and for service

Source record↗