Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Free space Thomson scattering to study high energy density shocks

A free space collective Thomson scattering system has been developed to study pulsed power produced plasmas. While most Thomson scattering diagnostics on pulsed power machines use a bundle of fibers to couple scattered light from the plasma to the spectrometer, this system used free space coupling of the light, which enabled a spatially continuous image of the plasma. Initial experiments with this diagnostic were performed on an inverse wire array generated by a 200 kA, 1100 ns rise time pulse power generator. The capabilities of this diagnostic were demonstrated by using the low frequency ion acoustic wave feature of the Thomson scattering spectra to measure the plasma flow velocity. The diagnostic was demonstrated to measure velocities between 20 and 40 km/s with an error of 4.7 km/s when fitting with a 600 μm spatial resolution or 8.9 km/s when fitting with a 150 μm spatial resolution. In some experiments, the diagnostic observed a bow shock in the plasma flow as the scattering intensity increased and flow velocity decreased.

47 OTHER INSTRUMENTATION↗

NASA Tech Briefs, April 2011

Topics covered include: Amperometric Solid Electrolyte Oxygen Microsensors with Easy Batch Fabrication; Two-Axis Direct Fluid Shear Stress Sensor for Aerodynamic Applications; Target Assembly to Check Boresight Alignment of Active Sensors; Virtual Sensor Test Instrumentation; Evaluation of the Reflection Coefficient of Microstrip Elements for Reflectarray Antennas; Miniaturized Ka-Band Dual-Channel Radar; Continuous-Integration Laser Energy Lidar Monitor; Miniaturized Airborne Imaging Central Server System; Radiation-Tolerant, SpaceWire-Compatible Switching Fabric; Small Microprocessor for ASIC or FPGA Implementation; Source-Coupled, N-Channel, JFET-Based Digital Logic Gate Structure Using Resistive Level Shifters; High-Voltage-Input Level Translator Using Standard CMOS; Monitoring Digital Closed-Loop Feedback Systems; MASCOT - MATLAB Stability and Control Toolbox; MIRO Continuum Calibration for Asteroid Mode; GOATS Image Projection Component; Coded Modulation in C and MATLAB; Low-Dead-Volume Inlet for Vacuum Chamber; Thermal Control Method for High-Current Wire Bundles by Injecting a Thermally Conductive Filler; Method for Selective Cleaning of Mold Release from Composite Honeycomb Surfaces; Infrared-Bolometer Arrays with Reflective Backshorts; Commercialization of LARC (trade mark) -SI Polyimide Technology; Novel Low-Density Ablators Containing Hyperbranched Poly(azomethine)s; Carbon Nanotubes on Titanium Substrates for Stray Light Suppression; Monolithic, High-Speed Fiber-Optic Switching Array for Lidar; Grid-Tied Photovoltaic Power System; Spectroelectrochemical Instrument Measures TOC; A Miniaturized Video System for Monitoring Drosophila Behavior; Hydrofocusing Bioreactor Produces Anti-Cancer Alkaloids; Creep Measurement Video Extensometer; Radius of Curvature Measurement of Large Optics Using Interferometry and Laser Tracker n-B-pi-p Superlattice Infrared Detector; Safe Onboard Guidance and Control Under Probabilistic Uncertainty; General Tool for Evaluating High-Contrast Coronagraphic Telescope Performance Error Budgets; Hidden Statistics of Schroedinger Equation; Optimal Padding for the Two-Dimensional Fast Fourier Transform; Spatial Query for Planetary Data; Higher Order Mode Coupling in Feed Waveguide of a Planar Slot Array Antenna; Evolutionary Computational Methods for Identifying Emergent Behavior in Autonomous Systems; Sampling Theorem in Terms of the Bandwidth and Sampling Interval; Meteoroid/Orbital Debris Shield Engineering Development Practice and Procedure; Self-Balancing, Optical-Center-Pivot, Fast-Steering Mirror; Wireless Orbiter Hang-Angle Inclinometer System; and Internal Electrostatic Discharge Monitor - IESDM.

Source record↗

The Design, Implementation, and Performance of the Astro-H SXS Calorimeter Array and Anti-Coincidence Detector

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The SXS has a square array of 36 microcalorimeters at the focal plane. These calorimeters consist of ion-implanted silicon thermistors and HgTe thermalizing x-ray absorbers. These devices have demonstrated a resolution of better than 4.5 eV at 6 keV when operated at a heat-sink temperature of 50 mK. We will discuss the basic physical parameters of this array, including the array layout, thermal conductance of the link to the heat sink, resistance function, absorber details, and means of attaching the absorber to the thermistor-bearing element. We will also present the thermal characterization of the whole array, including thermal conductance and crosstalk measurements and the results of pulsing the frame temperature via alpha particles, heat pulses, and the environmental background. A silicon ionization detector is located behind the calorimeter array and serves to reject events due to cosmic rays. We will briefly describe this anti-coincidence detector and its performance.

x-ray calorimeter↗

Design, Implementation, and Performance of the Astro-H SXS Calorimeter Array and Anticoincidence Detector

The calorimeter array of the JAXA Astro-H (renamed Hitomi) soft x-ray spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The SXS had a square array of 36 x-ray calorimeters at the focal plane. These calorimeters consisted of ion-implanted silicon thermistors and HgTe thermalizing x-ray absorbers. These devices demonstrated a resolution of better than 4.5 eV at 6 keV when operated at a heat-sink temperature of 50 mK. We will discuss the basic physical parameters of this array, including the array layout, thermal conductance of the link to the heat sink, resistance function, absorber details, and means of attaching the absorber to the thermistor-bearing element. We will also present the thermal characterization of the whole array, including thermal conductance and crosstalk measurements and the results of pulsing the frame temperature via alpha particles, heat pulses, and the environmental background. A silicon ionization detector was located behind the calorimeter array and served to reject events due to cosmic rays. We will briefly describe this anticoincidence detector and its performance.

Kilbourne, Caroline A.↗

Emission Inventories from Natural Gas Storage Facilities using Regional Frequency Comb Laser Monitoring and Aircraft Flyovers. Final Report

The project centers around a ground-based regional methane sensor developed by the CU/NIST team members under the DOE ARPA-E MONITOR program, and sophisticated aircraft measurement techniques developed by the UCD/Scientific Aviation team (responsible for a recent Science publication quantifying the Aliso Canyon storage field release). The dual frequency-comb spectrometer is an invisible, eye-safe laser capable of measuring atmospheric methane concentrations along beam paths 1+ miles in length with high precision and stability (<1 ppb methane over 1 mile). The CU/NIST team has developed a unique approach to using a single, central spectrometer to locate and size methane emissions as small as 6 scfh from specific gas field structures within the 1+ mile range of the laser. Deployment involves the stationing of small cubic mirrors at strategic locations across the gas storage site. The mirrors direct light from the spectrometer back to a detector, where methane concentrations are recorded based on light absorption at specific wavelengths. The measurements are coupled with high resolution gas transport models based on meteorological measurements (wind, etc.) to determine the precise location and emission rate of methane sources. The calibration-free and continuous nature of dual frequency-comb spectrometer measurements means that a large area can be monitored continuously for temporal variability of emissions over long periods of time. The aircraft measurements involve spiral flights around storage facilities with a sensitive ethane/methane measurement package. Upwind/downwind concentration comparisons and wind data provide total facility emissions data. During this project, a new micrometeorological package was integrated onto the Scientific Aviation aircraft to provide even greater emissions quantification capability. In this project, the ground-based measurement system was deployed for 11 months (to capture seasonal variability) at a West Coast storage facility, together with a campaign of twice monthly aircraft total facility emissions flights. The data from these two modalities was combined to quantify the methane emissions from the facility with first-of-its-kind temporal and spatial detail. Concurrent with this deployment, the aircraft team performed flights to quantify emissions at a wider array of previously un-surveyed storage sites. The ground-based measurement system was then moved to an additional site of differing total storage and delivery capacity. Aircraft mass balance flights continued, repeatedly surveying (twice monthly) this site, as well as surveying a large number of previously un-assessed sites spanning a variety of size, reservoir type and age. Assessment of ground-based, temporally and spatially detailed methane emissions information alongside aircraft-derived methane total facility emissions information led to an improved understanding of emissions, relevant for inventories of the natural gas storage sector. In particular, this work provided temporal detail (seasonal of emissions and frequency of leaks) to stakeholders and personnel responsible for updates to the EPA’s GHGI. The impact of the proposed work has been a dramatic improvement in the temporal, spatial, and site- and type- specific detail and quantification of emissions inventories for the natural gas storage sector. This work directly benefits the EPA’s GHGI, directly ameliorates the environmental impacts and public health and safety of the natural gas storage sector, and aids policymakers and industry to make sound choices with respect to management and regulation.

03 NATURAL GAS↗

Digital array scanned interferometers for astronomy

Investigations are reported of digital array scanned interferometers (DASI) with silicon CCD array detectors to define the operational capabilities of a mapping (polarimetric) spectrometer for astronomical applications based on these instruments. For spectral mapping, spatially resolved spectra using a cylindrical lens to image in the interferometers's redundant coordinate are given. The signal-to-noise characteristics of the Fourier transformed data are demonstrated with regard to the effects of a rectangular sampling function, spectral multiplexing and the pixel-to-pixel variation of the CCD array. These data indicate that DASIs can offer simple, versatile (polarization) mapping spectrometers suitable for spectral mapping observations from the ultraviolet to the infrared of extended sources at variable spatial resolution, particularly where long term stable operation is essential, as for spacecraft instruments.

Smith, Wm. Hayden↗

Multi-Channel Correlator Array-Fed Microwave Radiometer

Multiband passive microwave imagery in X to W Bands has a nearly 40-year history of utilization for measurement of multiple geophysical parameters (e.g., precipitation rate, ocean surface wind speed, sea ice concentration, and land surface temperature). Spatial resolution is limited by aperture size, and although aperture sizes have grown to 1-2 meters, current capability will not meet future spatial resolution needs. As aperture size increases, new antenna feed techniques are needed to maintain contiguous coverage and obtain Nyquist sampling. Here we apply the correlator array fed radiometer architecture adapted from radio astronomy and show how it can meet emerging needs. Simulation results of a 0.8-m, 36.5-GHz, array-fed reflector (equivalent to 20 meters at 1.41 GHz) show the feasibility of creating multiple over-lapping beams.

Microwave radiometer↗

Interferometric synthetic aperture microwave radiometry for the remote sensing of the earth

Interferometric aperture synthesis is presented as an alternative to real aperture measurements of the earth's brightness temperature from low earth orbit. The signal-to-noise performance of a single interferometric measurement is considered, and the noise characteristics of the brightness temperature image produced from the interferometer measurements are discussed. The sampling requirements of the measurements and the resulting effects of the noise in the measurements on the image are described. The specific case of the electronically steered thinned array radiometer (ESTAR) currently under construction is examined. The ESTAR prototype is described in detail sufficient to permit a performance evaluation of its spatial and temperature resolution. Critical aspects of an extension of the ESTAR sensor to a larger spaceborne system are considered. Of particular importance are the number and placement of antenna elements in the imaging array. A comparison of the implementation methodologies of radio astronomy and earth remote sensing is presented along with the effects of the source brightness distribution, the antenna array configuration and the method used for array scanning.

Ruf, Christopher S.↗

The Design, Implementation, and Performance of the Astro-H SXS Aperture Assembly and Blocking Filters

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The properties that make the SXS array a powerful x-ray spectrometer also make it sensitive to photons from the entire electromagnetic band, and particles as well. If characterized as a bolometer, it would have a noise equivalent power (NEP) of less than 4x10(exp -18) W/(Hz)0.5(exp 0.5). Thus it was imperative to shield the detector from thermal radiation from the instrument and optical and UV photons from the sky. Additionally, it was necessary to shield the coldest stages of the instrument from the thermal radiation emanating from the warmer stages. Both of these needs are addressed by a series of five thin-film radiation-blocking filters, anchored to the nested temperature stages, that block long-wavelength radiation while minimizing x-ray attenuation. The aperture assembly is a system of barriers, baffles, filter carriers, and filter mounts that supports the filters and inhibits their potential contamination. The three outer filters also have been equipped with thermometers and heaters for decontamination. We present the requirements, design, implementation, and performance of the SXS aperture assembly and blocking filters.

radiation - blocking filters↗

A Simplified Theory of Coupled Oscillator Array Phase Control

Linear and planar arrays of coupled oscillators have been proposed as means of achieving high power rf sources through coherent spatial power combining. In such - applications, a uniform phase distribution over the aperture is desired. However, it has been shown that by detuning some of the oscillators away from the oscillation frequency of the ensemble of oscillators, one may achieve other useful aperture phase distributions. Notable among these are linear phase distributions resulting in steering of the output rf beam away from the broadside direction. The theory describing the operation of such arrays of coupled oscillators is quite complicated since the phenomena involved are inherently nonlinear. This has made it difficult to develop an intuitive understanding of the impact of oscillator tuning on phase control and has thus impeded practical application. In this work a simpl!fied theory is developed which facilitates intuitive understanding by establishing an analog of the phase control problem in terms of electrostatics.

Pogorzelski, R. J.↗

The Dynamics of Coupled Oscillator Phase Control

Arrays of coupled oscillators have been proposed as means of realizing high power rf sources via coherent spatial power combining. In such applications, a uniform phase distribution over the aperture is usually desired. However, it has been shown that by detuning some of the oscillators away from the oscillation frequency of the ensemble of oscillators, one may achieve other useful aperture phase distributions. Of particular interest among those achievable are linear phase distributions because these result in steering of the output rf beam away from the broadside direction. The theory describing the behavior of such arrays of coupled oscillators is quite complicated since the phenomena involved are inherently nonlinear. However, a simplified theory has been developed which facilitates intuitive understanding. This simplified theory is based on a "continuum model" in which the aperture phase is represented by a continuous function of the aperture coordinates. A challenging aspect of the development of this theory is the derivation of appropriate boundary conditions at the edges or ends of the array.

Pogorzelski, R. J.↗

An LED Approach for Measuring the Photocatalytic Breakdown of Crystal Violet Dye

A simple technique to assess the reactivity of photocatalytic coatings sprayed onto transmissive glass surfaces was developed. This new method uses ultraviolet (UV) gallium nitride (GaN) light-emitting diodes (LEDs) to drive a photocatalytic reaction (the photocatalytic breakdown of a UV-resistant dye applied to a surface coated with the semiconductor titanium dioxide); and then a combination of a stabilized white light LED and a spectrometer to track the dye degradation as a function of time. Simple, standardized evaluation techniques that assess photocatalytic materials over a variety of environmental conditions, including illumination level, are not generally available and are greatly needed prior to in situ application of photocatalytic technologies. To date, much research pertaining to this aspect of photocatalysis has been limited and has focused primarily on laboratory experiments using mercury lamps. Mercury lamp illumination levels are difficult to control over large ranges and are temporally modulated by line power, limiting their use in helping to understand and predict how photocatalytic materials will behave in natural environmental settings and conditions. The methodology described here, using steady-state LEDs and time series spectroradiometric techniques, is a novel approach to explore the effect of UV light on the photocatalytic degradation of a UV resistant dye (crystal violet). GaN UV LED arrays, centered around 365 nm with an adjustable DC power supply, are used to create a small, spatially uniform light field where the steady state light level can be varied over three to four orders of magnitude. For this study, a set of glass microscope slides was custom coated with a thinly sprayed layer of photocatalytic titanium dioxide. Crystal violet was then applied to these titanium-dioxide coated slides and to uncoated control slides. The slides were then illuminated at various light levels from the dye side of the slide by the UV LED array. To monitor dye degradation on the slides over time, a temperature-stabilized white light LED was used to illuminate the opposite side of the slides. As the dye degraded, the amount of light from the white light LED transmitted through the slide was monitored with a spectrometer and subsequently analyzed to determine and compare the rate of dye degradation for photocatalytically coated versus uncoated slide surfaces. The long-term stability of the spectrometer/white light LED combination, which required only a single reference spectra to be taken for a time series sequence of several hours, enabled accurate measurements of transmitted light over time. Time series transmission curves were generated and results demonstrated that over time the transmission increased much more rapidly on the coated slides than on the control slides. This experimental configuration and methodology for photocatalytic activity measurement minimizes many external variable effects and allows low light level studies to be performed. This study also compares the advantages of this novel LED light source design to traditional mercury lamp systems and non-LED lamp approaches that have conventionally been used. The methodology and experimental design research summarized in this abstract is partly funded by the Department of Homeland Security, Science and Technology Directorate, and by the NASA Stennis Space Center Innovative Partnerships Program.

Ryan, Robert E.↗

Gas puff imaging on the TCV tokamak

We present the design and operation of a suite of Gas Puff Imaging (GPI) diagnostic systems installed on the Tokamak à Configuration Variable (TCV) for the study of turbulence in the plasma edge and Scrape-Off-Layer (SOL). These systems provide the unique ability to simultaneously collect poloidal 2D images of plasma dynamics at the outboard midplane, around the X-point, in both the High-Field Side (HFS) and Low-Field Side (LFS) SOL, and in the divertor region. We describe and characterize an innovative control system for deuterium and helium gas injection, which is becoming the default standard for the other gas injections at TCV. Extensive pre-design studies and the different detection systems are presented, including an array of avalanche photodiodes and a high-speed CMOS camera. First results with spatial and time resolutions of up to ≈2 mm and 0.5 µs, respectively, are described, and future upgrades of the GPI diagnostics for TCV are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical signal processing

The article discusses several optical configurations used for signal processing. Electronic-to-optical transducers are outlined, noting fixed window transducers and moving window acousto-optic transducers. Folded spectrum techniques are considered, with reference to wideband RF signal analysis, fetal electroencephalogram analysis, engine vibration analysis, signal buried in noise, and spatial filtering. Various methods for radar signal processing are described, such as phased-array antennas, the optical processing of phased-array data, pulsed Doppler and FM radar systems, a multichannel one-dimensional optical correlator, correlations with long coded waveforms, and Doppler signal processing. Means for noncoherent optical signal processing are noted, including an optical correlator for speech recognition and a noncoherent optical correlator.

Casasent, D.↗

Observations of the motion and distribution of the ionized gas in the central parsec of the Galaxy

High spatial and spectral resolution observations of Ne II (12.8 microns) emission show a complex array of small sources of various velocities within the central 20 arcsec of the Galaxy. More extended clouds of ionized gas are seen outside this region. Many of the localized sources are associated with 10-micron continuum peaks. Clouds in the central region appear to be rotating about an axis tilted 60 to 90 deg from that of galactic rotation. Their velocity distribution indicates a mass of about 8 million solar masses for the central parsec (diameter) of the Galaxy. Sensitive searches for more highly ionized species in the galactic center indicate that the region is ionized by radiation with a cooler spectrum than that found in other H II regions.

Lacy, J. H.↗

Multispectral Resource Sampler - An experimental satellite sensor for the mid-1980s

An experimental pushbroom scan sensor, the Multispectral Resource Sampler (MRS), being developed by NASA for a future earth orbiting flight is presented. This sensor will provide new earth survey capabilities beyond those of current sensor systems, with a ground resolution of 15 m over a swath width of 15 km in four bands. The four arrays are aligned on a common focal surface requiring no beamsplitters, thus causing a spatial separation on the ground which requires computer processing to register the bands. Along track pointing permits stereo coverage at variable base/height ratios and atmospheric correction experiments, while across track pointing will provide repeat coverage, from a Landsat-type orbit, of every 1 to 3 days. The MRS can be used for experiments in crop discrimination and status, rock discrimination, land use classification, and forestry.

Schnetzler, C. C.↗

A Shuttle Imaging Spectrometer Experiment for the late 1980's

The Shuttle Imaging Spectrometer Experiment (SISEX), proposed as a next experimental step in the development of advanced earth remote sensing technology, is capable of imaging the earth's surface simultaneously in 128 spectral bands covering the range from 0.4 to 2.5 micrometers. Laboratory and field measurements have suggested the utility of high-spectral-resolution remote sensing, and an aircraft-borne precursor to the SISEX has demonstrated the ability to distinguish among differing vegetation and rock types - in certain cases making unique identifications. The SISEX instrument utilizes an area-array focal plane, populated by visual- and infrared-sensitive detectors, to acquire simultaneous spatial and spectral information on a line-by-line basis. The spectrum is dispersed by means of a prism spectrometer. The performance analysis indicates that the scientific requirements for radiometric precision can be achieved using optics with an effective circular aperture of 11 cm.

Wellman, J. B.↗

Imagery with a Si:Bi 16 x 16 array

A description of the design and performance of an imaging spectrometer intended for operation in the 7 to 14 micron wavelength range is presented. It is based upon a 16 by 16 element Si:Bi hybrid array, a circular variable filter wheel, and a microcomputer data acquisition system. The spatial-spectral photometric performances were evaluated in the laboratory as well as field tested at astronomical observatories. The performance characteristics of the system are presented as well as laboratory and astronomical images.

Goebel, J. H.↗