Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

First Direct Imaging and Profiling TOF-SIMS Studies on Cutouts from Cavities Prepared by State-of-the-Art Treatments

Small amounts of interstitial impurities in the penetra-tion depth of superconducting radio frequency (SRF) cavities have a dramatic effect on the quality factors and maximum accelerating gradients. Here we report the first TOF-SIMS studies of cutouts from cavities prepared by all modern surface treatments, which allow a direct corre-lation of the impurity distribution with the observed cavity performance. Imaging capability of our instrument allows to avoid the possible issues associated with the ‘‘ghost’’ depth profiles appearing as a consequence of particulate surface contamination, which likely caused the inconclusive SIMS results on e.g. oxygen diffusion in the past.

43 PARTICLE ACCELERATORS↗

WINDPROF: Merged Best-Estimate Wind Profile Data – Block Island (WFIP3 Campaign)

WINDPROF provides 10-minute wind and turbulence profiles that integrate a scanning Doppler lidar, a profiling lidar, a 915 MHz radar wind profiler, and a surface met station across Northeast U.S. coastal and offshore sites during the WFIP3 campaign. Variables include wind speed, wind direction, vertical velocity, turbulence intensity, and turbulent kinetic energy, each with per-instrument quality control and inter-instrument agreement validation. Profiles are mapped to a standardized height grid – a dedicated near-surface level at the 10 m surface-wind height, 20 m spacing to 100 m, and 30 m spacing above – and carry component and derived uncertainty estimates. Heights are reported above ground level; the site's ground elevation is stored separately. The Block Island dataset covers 1 February 2024 – 8 September 2025.

17 WIND ENERGY↗

A Novel Dew Point Meter: Application to the Measurement of the Sulfuric Acid Dew Point for Combustion Flue Gas

Accurate knowledge of acid dew point is essential for industrial and applied combustion applications. Sulfur in the fuel or raw materials is converted to sulfur dioxide (SO2) during combustion, and a portion of the SO2 is oxidized to sulfur trioxide (SO3). The SO3 will react to form H2SO4 vapor when in the presence of water vapor. Even with just trace levels of H2SO4 vapor in the gas phase (1-10 ppm), the dew point can reach 100°C and higher. To avoid acid condensation and the resulting corrosion on heat recovery equipment, plant engineers must ensure that surface temperatures are above the acid dew point, but this decreases the efficiency of thermal energy recovery. Thus, there is a trade-off between minimizing equipment corrosion and maximizing thermal energy recovery, and the acid dew point is a key parameter for this optimization. Commercially available acid dew point meters use electric conductivity sensors. These sensors are known to greatly underestimate the dew point due to their low sensitivity. In addition, no validation testing has been reported for these units and they are often expensive. In this work, we analyze the theory of the sulfuric acid condensation and develop a novel dew point meter based on this analysis. The meter consists of a novel optical instrument that is designed to monitor the slightest appearance of condensation on a hydrophobic window surface as the surface temperature of the window is slowly decreased. In this way, an accurate measurement of the dew point is obtained under a wide range of concentrations. The basis of the instrument is that a collimated beam from a diode laser will generate forward scattered light when the beam encounters surface condensate, and a sophisticated array detector is used to sensitively monitor the onset of light scattering. The measurement procedures are established to rapidly find the acid dew point, while minimizing error. Further, to calibrate the dew point meter we developed a calibration system based on a liquid bubbler that can generate a stable gas flow with a known sulfuric acid dew point. Test results show that the dew point meter can accurately measure acid dew point over a wide range. For H2SO4 vapor concentrations as low as 6 ppm the acid dew point is measured with an error of only ~1°C. To demonstrate the versatility of this instrument, the dew point meter was adapted for use with a high-pressure flow cell to allow for measurements of the dew point of flue gas from pressurized oxy-fuel combustion in a 100 kWth pressurized reactor.

Cheng, Mao↗

The Ricor K508 cryocooler operational experience on Mars

The Mars Science Laboratory (Curiosity) landed successfully on Mars on August 5, 2012, eight months after launch. The chosen landing site of Gale Crater, located at 4.5 degrees south latitude, 137.4 degrees east longitude, has provided a much more benign environment than was originally planned for during the critical design and integration phases of the MSL Project when all possible landing sites were still being considered. The expected near-surface atmospheric temperatures at the Gale Crater landing site during Curiosity's primary mission (1 Martian year or 687 Earth days) are from −90°C to 0°C. However, enclosed within Curiosity's thermal control fluid loops the Chemistry and Mineralogy (CheMin) instrument is maintained at approximately +20°C. The CheMin instrument uses X-ray diffraction spectroscopy to make precise measurements of mineral constituents of Mars rocks and soil. The instrument incorporated the commercially available Ricor K508 Stirling cycle cryocooler to cool the CCD detector. After several months of brushing itself off, stretching and testing out its subsystems, Curiosity began the exploration of the Mars surface in October 2012. The CheMin instrument on the Mars Science Laboratory (MSL) received its first soil sample from Curiosity on October 24, and successfully analyzed its first soil sample. After a brief review of the rigorous Ricor K508 cooler qualification tests and life tests based on the original MSL environmental requirements this paper presents final pre-launch instrument integration and testing results, and details the operational data of the CheMin cryocooler, providing a snapshot of the resulting CheMin instrument analytical data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Weather Data from BSEC Weather Stations

This dataset provides measurements of temperature, humidity, rainfall, wind, and sunlight at Ambient Weather and OttHydro stations across Baltimore city. These surface weather stations were deployed by the Baltimore Social-Environmental Collaborative (BSEC) Urban Integrated Field Laboratory (UIFL) project, funded by the Department of Energy (DOE). This dataset currently contains measurements from 2023 to June 2026 and will be periodically updated to include more stations and recent observations when available. Data File Information This dataset contains surface weather measurements data in comma-separated value (CSV) format and documents that describe the weather stations, locations, and measured parameters and units. data/[TIMEAVG]/[YEAR]/BSEC-[STATIONID]_[SENSORTYPE]_[TIMEAVG]_[YEAR].csv Surface weather measurements data in CSV format, where STATIONID indicates the weather station, SENSORTYPE is the type of weather station ('AWS' = Ambient Weather Station and 'OTT' = 'OttHydro Station'), TIMEAVG is time period for each entry (= daily, hourly, or 5min), and YEAR indicate the year in which the measurements were made. Example data file name: BSEC-AAC_AWS_hourly_2023.csv. documents/Station_Locations.csv This CSV file provides location information and measurement start date for each surface weather station. documents/Weather_Station_Descriptions.pdf This document provides detailed description of the instruments along with their setup and accuracy of measurement. documents/File_Contents.pdf This document describes the contents on the data files, including time notation, weather parameters and units of measurement. documents/site-metadata/[STATOINID]-metadata.pdf These PDF files provide information on weather station sites, including land cover characteristics, station mounting, and photographs. Each PDF file corresponds to one station, as indicated by STATIONID.

Ambient Weather Stations↗

A new approach to vibrational sum frequency generation spectroscopy using near infrared pulse shaping

In this work, we have developed a multipurpose vibrational sum frequency generation (vSFG) spectrometer that is uniquely capable of probing a broad range of chemical species, each requiring different experimental conditions, without optical realignment. Here, we take advantage of arbitrary near infrared (NIR) waveform generation using a 4 f -pulse shaper equipped with a 2D spatial light modulator (SLM) to tailor upconversion pulses to meet sample dependent experimental requirements. This report details the experimental layout, details of the SLM calibration and implementation, and the intrinsic benefits/limitations of this new approach to vSFG spectroscopy. We have demonstrated the competency of this spectrometer by achieving an ~3-fold increase in spectral resolution compared to conventional spectrometers by probing the model dimethyl sulfoxide/air interface. We also show the ability to suppress nonresonant background contributions from electrode interfaces using time delayed asymmetric waveforms that are generated by the NIR pulse shaper. Lastly, it is expected that this advancement in instrumentation will broaden the types of samples researchers can readily study using nonlinear surface specific spectroscopies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Efficient Hot Electron Transfer from Small Au Nanoparticles

Many important chemical transformations enabled by plasmonic hot carrier photocatalysis have been reported, although their efficiencies are often too low for practical applications. Here, we examine how the efficiency of plasmon-induced hot electron transfer depends on the Au particle size in Au-tipped CdS nanorods. We show that with decreasing Au size, the plasmon width increases due to enhanced surface damping contributions. The excitation of Au nanoparticles leads to an instrument response time-limited ultrafast hot electron transfer process to CdS ($\ll$140 fs). The quantum efficiency of this process increases from ~1% to ~18% as the particle size decreases from 5.5 ± 1.1 to 1.6 ± 0.5 nm due to both enhanced hot electron generation and transfer efficiencies in small Au particles. Our finding suggests that decreasing plasmonic particle size is an effective approach for improving plasmon-induced hot carrier transfer efficiency and provides important insight for the rational improvement of plasmonic hot carrier-based devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Eddy Correlation Flux Measurement System (ECOR) Instrument Handbook

The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO 2 ) (and methane at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s North Slope of Alaska central facility [NSA Barrow], and at the ARM Mobile Facility (AMF) deployment at Oliktok Point). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO 2 concentration. The instruments used are: a fast-response, three-dimensional (3D) wind sensor (sonic anemometer) to obtain the orthogonal wind components and the speed of sound (SOS) (used to derive the air temperature), an open-path infrared gas analyzer (IRGA) to obtain the water vapor density and the CO 2 concentration, and an open-path infrared gas analyzer (IRGA) to obtain methane density and methane flux at NSA Barrow and at the AMF deployment at Oliktok Point. The ECOR systems are deployed at the locations where other methods for surface flux measurements (e.g., energy balance Bowen ratio [EBBR] systems) are difficult to employ, primarily at the north edge of a field of crops. A surface energy balance system (SEBS) has been installed collocated with each deployed ECOR system in SGP, NSA, Tropical Western Pacific (TWP), and each of three ARM Mobile Facilities. The surface energy balance system consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. Finally, the SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes.

47 OTHER INSTRUMENTATION↗

CHROMOSPHERIC SIGNATURES OF SMALL-SCALE FLUX EMERGENCE AS OBSERVED WITH NEW SOLAR TELESCOPE AND HINODE INSTRUMENTS

With the ever-increasing influx of high-resolution images of the solar surface obtained at a multitude of wavelengths, various processes occurring at small spatial scales have become a greater focus of our attention. Complex small-scale magnetic fields have been reported that appear to have enough stored energy to heat the chromosphere. While significant progress has been made in understanding small-scale phenomena, many specifics remain elusive. We present here a detailed study of a single event of disappearance of a magnetic dipole and associated chromospheric activity. Based on New Solar Telescope H{alpha} data and Hinode photospheric line-of-sight magnetograms and Ca II H images, we report the following. (1) Our analysis indicates that even very small dipoles (elements separated by about 0.''5 or less) may reach the chromosphere and trigger non-negligible chromospheric activity. (2) Careful consideration of the magnetic environment where the new flux is deposited may shed light on the details of magnetic flux removal from the solar surface. We argue that the apparent collision and disappearance of two opposite polarity elements may not necessarily indicate their cancellation (i.e., reconnection, emergence of a 'U' tube, or submergence of {Omega} loops). In our case, the magnetic dipole disappeared by reconnecting with overlying large-scale inclined plage fields. (3) Bright points (BPs) seen in off-band H{alpha} images are very well correlated with the Ca II H BPs, which in turn are cospatial with G-band BPs. We further speculate that, in general, H{alpha} BPs are expected to be cospatial with photospheric BPs; however, a direct comparison is needed to refine their relationship.

79 ASTRONOMY AND ASTROPHYSICS↗

High-Resolution Data for a Low-Resolution World

In the past 15 years, the upper section of Cañon de Valle has been severely altered by wildfires and subsequent runoff events. Loss of root structures on high-angle slopes results in debris flow and sediment accumulation in the narrow canyon bottom. The original intent of the study described here was to better understand the changes occurring in watershed soil elevations over the course of several post-fire years. An elevation dataset from 5 years post-Cerro Grande fire was compared to high-resolution LiDAR data from 14 years post-Cerro Grande fire (also 3 years post-Las Conchas fire). The following analysis was motivated by a problematic comparison of these datasets of unlike resolution, and therefore focuses on what the data reveals of itself. The objective of this study is to highlight the effects vegetation can have on remote sensing data that intends to read ground surface elevation.

47 OTHER INSTRUMENTATION↗

Ion Imaging Near a Reactive Surface

In this project, resonance enhanced multi-photon ionization followed by spatial mode ion imaging (REMPI-SMII) has been developed as a new tool for in-situ monitoring of local catalytic activity near a chemically active surface. A prototype experimental setup was developed for the demonstration, and initial results indicate this approach is feasible as a new diagnostic for online monitoring of catalytic reactions. The catalytic conversion of H 2 and D 2 to form HD over a Pt surface was carried out using a dual-molecular beam arrangement with reactant beams impinging on a structured Pt surface. The catalytic production of HD was successfully detected through the REMPI-SMII approach, and next steps were identified to improve the experimental design for better spatial resolution and mapping of catalytic surface activity.

47 OTHER INSTRUMENTATION↗

Very low pressure high power impulse triggered magnetron sputtering

A method and apparatus are described for very low pressure high powered magnetron sputtering of a coating onto a substrate. By the method of this invention, both substrate and coating target material are placed into an evacuable chamber, and the chamber pumped to vacuum. Thereafter a series of high impulse voltage pulses are applied to the target. Nearly simultaneously with each pulse, in one embodiment, a small cathodic arc source of the same material as the target is pulsed, triggering a plasma plume proximate to the surface of the target to thereby initiate the magnetron sputtering process. In another embodiment the plasma plume is generated using a pulsed laser aimed to strike an ablation target material positioned near the magnetron target surface.

47 OTHER INSTRUMENTATION↗

Field emission cathode gating for RF electron guns and planar focusing cathodes

A novel method of gating electron emission from field-emitter cathodes for radio frequency (RF) electrode guns and a novel cathode that provides a focused electron beam without the need for magnetic fields or a curved cathode surface are provided. The phase and strength of a predefined harmonic field, such as the 3rd harmonic field, are adjusted relative to a fundamental field to cause a field emission cathode to emit electrons at predefined times for the generation of high-brightness electron beams. The emission time is gated responsive to the combined harmonic and fundamental fields and the response of the FE cathode to the combined fields. A planar focusing cathode includes a selected dielectric material, such as a ceramic material, to provide an electron beam emission surface. Metal surfaces are provided both radially around and behind the dielectric material to shape the electric fields that accelerate and guide the beam from the cathode surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning nonlinear dielectric potentiometry

Measuring spontaneous polarization and permanent dipoles on surfaces and interfaces on the nanoscale is difficult because the induced electrostatic fields and potentials are often influenced by other phenomena such as the existence of monopole fixed charges, screening charges, and contact potential differences. A method based on tip-sample capacitance detection and bias feedback is proposed which is only sensitive to polarization- or dipole-induced potentials, unlike Kelvin probe force microscopy. The feasibility of this method was demonstrated by simultaneously measuring topography and polarization-induced potentials on a reconstructed Si(111)-(7 × 7) surface with atomic resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of CERES SYN1deg Radiative Fluxes with Those Derived from Observations at the ARM ENA Site

Profiles of radiative fluxes simulated from thermodynamic and cloud observations made at the Atmospheric Radiation Measurement (ARM) eastern North Atlantic (ENA) site for a 6-yr period are termed as ENARad. ENARad radiative fluxes are compared to those from the Clouds and the Earth’s Radiant Energy System (CERES) 1°-resolution synoptic product (SYN1deg)-simulated radiative flux profiles as well as the CERES instrument observed top-of-the-atmosphere (TOA) fluxes and ground site broadband radiometer measurements. Monthly average differences between ENARad and surface radiometer reported fluxes and differences between ENARad, SYN1deg, and observed fluxes at TOA were statistically insignificant. SYN1deg significantly overestimated surface downwelling shortwave flux by 12 ± 52 W m −2 and surface downwelling longwave flux by 5 ± 20 W m −2 on monthly time scales. Such overestimations were traced to a moister and warmer subcloud layer, a drier cloud layer, and a moister and colder above-cloud-free troposphere in the ancillary thermodynamic and cloud properties used by SYN1deg than observed. Similarly, low-cloud coverage, boundaries, and liquid water paths utilized by SYN1deg were also significantly higher than observed. Intramodel differences in the hourly values of shortwave fluxes exceeded 100 W m−2 at the TOA and the surface. These differences were also due to inaccuracies in the representation of low-cloud properties within the SYN1deg product relative to those determined by ENA ARM instrumentation and used as ENARad ancillary data. Results presented are relevant to investigations employing the CERES SYN1deg data product, studies that estimate radiative fluxes from surface-based or satellite-borne observations, and comparative analyses of radiative fluxes derived using different methodological approaches.

54 ENVIRONMENTAL SCIENCES↗

Tracing the Cosmological Evolution of Stars and Cold Gas with CMB Spectral Surveys

A full account of galaxy evolution in the context of ΛCDM cosmology requires measurements of the average star-formation rate (SFR) and cold gas abundance across cosmic time. Emission from the CO ladder traces cold gas, and [C ii] fine structure emission at 158 μm traces the SFR. Intensity mapping surveys the cumulative surface brightness of emitting lines as a function of redshift, rather than individual galaxies. CMB spectral distortion instruments are sensitive to both the mean and anisotropy of the intensity of redshifted CO and [C ii] emission. Large-scale anisotropy is proportional to the product of the mean surface brightness and the line luminosity-weighted bias. The bias provides a connection between galaxy evolution and its cosmological context, and is a unique asset of intensity mapping. Cross-correlation with galaxy redshift surveys allows unambiguous measurements of redshifted line brightness despite residual continuum contamination and interlopers. Measurement of line brightness through cross-correlation also evades cosmic variance and suggests new observation strategies. Galactic foreground emission is ≈10{sup 3} times larger than the expected signals, and this places stringent requirements on instrument calibration and stability. Under a range of assumptions, a linear combination of bands cleans continuum contamination sufficiently that residuals produce a modest penalty over the instrumental noise. For PIXIE, the 2σ sensitivity to CO and [C ii] emission scales from ≈5×10{sup −2} kJy sr{sup −1} at low redshift to ≈2 kJy sr{sup −1} by reionization.

79 ASTRONOMY AND ASTROPHYSICS↗

Cloud optical and microphysical properties derived from ground-based and satellite sensors over a site in the Yangtze Delta region: CLOUD PROPERTIES IN EASTERN CHINA

Comprehensive surface - based retrievals of cloud optical and microphysical properties were made at Taihu, a highly polluted site in central Yangtze Delta region, during a research campaign from May 2008 to December 2009. C loud optical depth (COD) , effective radius (R e ) and liquid water path (LWP) were retrieved from measurements made with a suite of ground - based and space - borne instruments, including an Analytical Spectral Devices (ASD) spectroradiometer , a Multi - Filter Rotating Shadowband R adiometer (MFRSR) , a Multichannel Microwave Radiometer Profiler (MWRP), and the Moderate Resolution Imaging Spectroradiometer ( MODIS) on Terra and Aqua satellites . Retrievals from zenith radiance measurements capture better the temporal variation of cloud properties than do retrievals from hemispherical fluxes . Annual mean LWP, COD and R e are 115.8 ± 90.8 g/m 2 , 28.5 ± 19.2, and 6.9 ± 4.2 μ m . Over 90% of LWP is less than 250 g/m 2 . Most of COD (>90%) fall s between 5 and 60 and ~ 80% of R e is less than 10 μ m . Maximum ( minimum ) values of LWP and R e occur in summer ( winter ); COD is highest in winter and spring. R aining and non - raining clouds have significant difference s in LWP, COD and R e . R ainfall frequency i s best correlated with LWP, followed by COD and R e . Cloud properties retrieved from multiple ground - based instruments are also compared with those from satellite retrievals. On average, relative to surface retrievals, mean differences of satellite retrievals in cloud LWP, COD and R e were - 33.6 g/m 2 ( - 26.4%), - 5.8 ( - 31.4%), and 2.9 μ m (29.3% ) for 11 MODIS - Terra overpasses , and - 43.3 g/m 2 ( - 2 2.3 %), - 3.0 ( - 10.0 %) and - 1.3 μ m ( - 12.0 %) for 8 MODIS - Aqua 40 overpasses, respectively. These discrep ancies indicate that MODIS cloud products still suffer 41 from large uncertainties in this region

Liu, Jianjun↗

CRDS with a VECSEL for broad-band high sensitivity spectroscopy in the 2.3 μm window

The integration of an industry ready packaged Sb-based Vertical-External-Cavity Surface-Emitting-Laser (VECSEL) into a Cavity Ring Down Spectrometer (CRDS) is presented. The instrument operates in the important 2.3 μm atmospheric transparency window and provides a high sensitivity (minimum detectable absorption of 9 × 10{sup −11} cm{sup −1}) over a wide spectra range. The VECSEL performances combine a large continuous tunability over 120 cm{sup −1} around 4300 cm{sup −1} together with a powerful (∼5 mW) TEM{sub 00} diffraction limited beam and linewidth at MHz level (for 1 ms of integration time). The achieved performances are illustrated by high sensitivity recordings of the very weak absorption spectrum of water vapor in the region. The developed method gives potential access to the 2-2.7 μm range for CRDS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗