Search NASA⌕ Search

SEARCH · Search NASA

Results for “system value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Influence of Lipiodol Agent on Proton Beam Range in Radiotherapy Planning Using Computed Tomography for Hepatocellular Carcinoma

Purpose: To evaluate the influence of lipiodol on the proton beam range, which has not yet been determined. Methods and Materials: Two computed tomography (CT) data sets were obtained with a T25-flask containing lipiodol and water that was placed above a water phantom. The plan with the lipiodol CT images was performed, and then a verification plan was applied to the water CT images. The actual proton beam ranges in the lipiodol and water were measured under same conditions, and we compared the calculated proton beam range in the treatment planning system with measured values. Results: The calculated distal range in the treatment planning system was 12 cm in water, which was 3.87 cm longer than that in lipiodol (8.13 cm). In contrast, the measured distal range was 12 {+-} 0.01 cm in water, which was 0.21 {+-} 0.01 cm longer than that of lipiodol (11.78 {+-} 0.01 cm). A 3.65 {+-} 0.01-cm range shift was found in the calculated range compared with the measured range. For 10 hepatocellular carcinoma patients, the distal range in the verification plan with the corrected CT images in which the Hounsfield unit (HU) value of lipiodolized lesion was replaced with the average HU value of the surrounding tissue was 0.61 {+-} 0.26 cm (range, 0.26-0.99) longer than that in the plan with uncorrected CT images. Conclusions: It could be relevant for the purposes of range calculation of proton beams in the treatment planning system that the HU value of a lipiodolized lesion is replaced by the average HU value of the surrounding normal tiss0008.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Physical and psychophysical characterization of a novel clinical system for digital mammography

Purpose: In recent years, many approaches have been investigated on the development of full-field digital mammography detectors and implemented in practical clinical systems. Some of the most promising techniques are based on flat panel detectors, which, depending on the mechanism involved in the x-ray detection, can be grouped into direct and indirect flat panels. Direct detectors display a better spatial resolution due to the direct conversion of x rays into electron-hole pairs, which do not need an intermediate production of visible light. In these detectors the readout is usually achieved through arrays of thin film transistors (TFTs). However, TFT readout tends to display noise characteristics worse than those from indirect detectors. To address this problem, a novel clinical system for digital mammography has been recently marketed based on direct-conversion detector and optical readout. This unit, named AMULET and manufactured by FUJIFILM, is based on a dual layer of amorphous selenium that acts both as a converter of x rays (first layer) and as an optical switch for the readout of signals (second layer) powered by a line light source. The optical readout is expected to improve the noise characteristics of the detector. The aim is to obtain images with high resolution and low noise, thanks to the combination of optical switching technology and direct conversion with amorphous selenium. In this article, the authors present a characterization of an AMULET system. Methods: The characterization was achieved in terms of physical figures as modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE), and contrast-detail analysis. The clinical unit was tested by exposing it to two different beams: 28 kV Mo/Mo (namely, RQA-M2) and 28 kV W/Rh (namely, W/Rh). Results: MTF values of the system are slightly worse than those recorded from other direct-conversion flat panels but still within the range of those from indirect flat panels: The MTF values of the AMULET system are about 45% and 15% at 5 and 8 lp/mm, respectively. On the other hand, however, AMULET NNPS results are consistently better than those from direct-conversion flat panels (up to two to three times lower) and flat panels based on scintillation phosphors. DQE results lie around 70% when RQA-M2 beams are used and approaches 80% in the case of W/Rh beams. Contrast-detail analysis, when performed by human observers on the AMULET system, results in values better than those published for other full-field digital mammography systems. Conclusions: The novel clinical unit based on direct-conversion detector and optical reading presents great results in terms of both physical and psychophysical characterizations. The good spatial resolution, combined with excellent noise properties, allows the achievement of very good DQE, better than those published for clinical FFDM systems. The psychophysical analysis confirms the excellent behavior of the AMULET unit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Capacity Value of Wind Power - Summary

Power systems are planned such that they have adequate generation capacity to meet the load, according to a defined reliability target. The increase in the penetration of wind generation in recent years has led to a number of challenges for the planning and operation of power systems. A key metric for generation system adequacy is the capacity value of generation. The capacity value of a generator is the contribution that a given generator makes to generation system aequacy. The variable and stochastic nature of wind sets it apart from conventional energy sources. As a result, the modeling of wind generation in the same manner as conventional generation for capacity value calculations is inappropriate. In this paper a preferred method for calculation of the capacity value of wind is described and a discussion of the pertinent issues surrounding it is given. Approximate methods for the calculation are also described with their limitations highlighted. The outcome of recent wind capacity value analyses in Europe and North America, along with some new analysis, are highlighted with a discussion of relevant issues also given.

17 WIND ENERGY↗

Systems and methods for data analytics for virtual energy audits and value capture assessment of buildings

A system may provide virtual energy audits of one or more target buildings. The system may retrieve weather data and energy usage data specific to a given target building from a weather server and a utility server, respectively. The system may store predefined building characteristics corresponding to the given target building in local memory. Based on the weather data, energy usage data, and/or predefined building characteristics, the system may generate one or more building markers that characterize the energy usage and efficiency of the given target building. Building efficiency diagnostics and energy conservation prognostics may be generated based on the building markers and may be sent by the system to be displayed via a user interface of a client device. The energy conservation prognostics may include one or more energy conservation measure recommendations and corresponding predicted cost/energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Capacity Value of PV and Wind Generation in the NV Energy System

Calculation of photovoltaic (PV) and wind power capacity values is important for estimating additional load that can be served by new PV or wind installations in the electrical power system. It also is the basis for assigning capacity credit payments in systems with markets. Because of variability in solar and wind resources, PV and wind generation contribute to power system resource adequacy differently from conventional generation. Many different approaches to calculating PV and wind generation capacity values have been used by utilities and transmission operators. Using the NV Energy system as a study case, this report applies peak-period capacity factor (PPCF) and effective load carrying capability (ELCC) methods to calculate capacity values for renewable energy sources. We show the connection between the PPCF and ELCC methods in the process of deriving a simplified approach that approximates the ELCC method. This simplified approach does not require generation fleet data and provides the theoretical basis for a quick check on capacity value results of PV and wind generation. The diminishing return of capacity benefit as renewable generation increases is conveniently explained using the simplified capacity value approach.

capacity value↗

Learning Deep Neural Network Representations for Koopman Operators of Nonlinear Dynamical Systems

The Koopman operator has recently garnered much attention for its value in dynamical systems analysis and data-driven model discovery. However, its application has been hindered by the computational complexity of extended dynamic mode decomposition; this requires a combinatorially large basis set to adequately describe many nonlinear systems of interest, e.g. cyber-physical infrastructure systems, biological networks, social systems, and fluid dynamics. Often the dictionaries generated for these problems are manually curated, requiring domain-specific knowledge and painstaking tuning. In this paper we introduce a deep learning framework for learning Koopman operators of nonlinear dynamical systems. We show that this novel method automatically selects efficient deep dictionaries, outperforming state-of-the-art methods. We benchmark this method on partially observed nonlinear systems, including the glycolytic oscillator and show it is able to predict quantitatively 100 steps into the future, using only a single timepoint, and qualitative oscillatory behavior 400 steps into the future.

koopman operators, machine learning, deep learning↗

Application of Manufacturing Quality Management Principles to PV System Installations

To help SETO/DOE achieve its goals, the IBTS team proposed a project addressing system reliability by improving installation standards and quality management. The proposed approach was designed to help achieve measurable reductions in installation defect density and improvements in the performance of PV systems by optimizing design and installation of residential and commercial PV systems. This approach addressed the soft costs associated with installations and quality management. The project demonstrated improved system reliability and reduced PV system installation costs. The software developed improved operations, decreased risk, and increased the overall value of PV systems across their lifecycle. The project used several data collection methods, including extensive industry surveys, face-to-face high-level interviews at industry conferences, stakeholder teleconferences, and in-depth interviews conducted by IBTS staff. Results from the research found the industry needs a uniform assessment method for national providers to be more efficient; the software should support both code officials and installers; most industry stakeholders would find value in a centralized software system that allows them to collect, report, and review information on in-process and completed solar installations; and mobile solutions that bridge existing knowledge gaps with inspectors and integrate with existing methodologies (such as permitting software) are of great value. The software solution developed is web-based, allowing for national access, and is built on a Google Firebase platform that can handle significant users and data. It can be used onsite or remotely, allowing for code compliance to continue despite ongoing pandemic related delays or shutdowns for local economies. The information provided by the software tool allows users to uniformly assess a system for compliance and use that aggregated data to identify training topics or create internal process designed to improving issues and reducing occurrence. This solution has multiple benefits in managing quality at time of use and promoting an increase in future safety and quality through education. Perhaps most importantly, this software increases public safety by ensuring compliance of installed systems and allows for local AHJs to remotely engage specialized and qualified solar specific expertise for oversite of the installation in their jurisdictions. Data analysis provides the quality feedback loop identifying the root cause of failure and drives installation practices to improve through training and education, resulting in systems with higher performance, greater reliability, and reduced operations and maintenance costs. With the successful completion of this project, the industry can expect reduced soft costs and increased performance and safety and will ultimately benefit from longer performing systems that cost less to operate.

14 SOLAR ENERGY↗

Nonstationary Problem of Complex Heat Transfer in a System of Semitransparent Bodies with Boundary-Value Conditions of Diffuse Reflection and Refraction of Radiation

We consider a nonstationary initial boundary-value problem describing complex (radiative-conductive) heat transfer in a system of semitransparent bodies. To describe radiation propagation, we use the radiation transfer equation with boundary-value conditions of diffuse reflection and refraction of radiation. We take into account that the radiation intensity and optical properties of bodies depend on the radiation frequency. The unique solvability of a weak solution is established. The comparison theorem is proved. A priori estimates of a weak solution as well as its regularity are obtained.

97 MATHEMATICS AND COMPUTING↗

Fluctuation removal around spectral and temporal constancy limits via use of an extended space expectation value weight function for singular quantum systems

This work is a new extension to our a very recent work whose paper will appear in the proceedings of a very recent international conference. What we have done in the previous work is the use of a weight operator to suppress the singularities causing nonexistence of some of temporal Maclaurin expansion coefficients. The weight operator has been constructed in such a way that certain number of expectation values of position operator’s first positive integer powers with and without the chosen weight operator match. Therein this match has not been considered for the momentum operator’s corresponding power expectation values and a finite linear combination of the spatial variable’s first reciprocal powers has been used in the construction of the weight operator. Here, that approach is extended to the case where matches for both position and momentum operators are considered and the weight operator involves finite linear combinations of the spatial variable’s both positive integer powers and their reciprocals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Variable Renewable Energy Participation in U.S. Ancillary Services Markets: Economic Evaluation and Key Issues

Variable renewable energy (VRE) is not yet meaningfully participating in U.S. ancillary services (AS) markets. VRE participation in AS markets could provide a new source of revenues for VRE resource owners to offset declining energy and capacity values and a new tool for power system operators to address emerging system constraints. This paper uses a price-taker dispatch model and historical prices to estimate the economic value of standalone and hybrid (battery-paired) VRE participation in AS markets, from resource owner and electricity system perspectives, in each of the seven U.S. independent system operator and regional transmission organization (ISO/RTO) markets. Across ISO/RTO markets, average (2015-2019) simulated incremental revenues from regulation market participation were $\$$0.0-2.9/MWh (+0-15% of revenue without participation) for standalone VRE owners and $\$$1-33/MWh (+1-69%) for hybrid VRE owners. However, ISO/RTO reserve markets are relatively thin and have the potential to become saturated by energy storage projects that are currently in ISO/RTO interconnection queues. In most markets, standalone and hybrid VRE were able to provide regulation reserves during periods with high regulation prices, suggesting that VRE participation in AS markets could have high system value. The analysis highlights the value of separate upward and downward regulation products and suggests that ISOs/RTOs might consider initially focusing on enabling hybrid VRE provision of AS.

14 SOLAR ENERGY↗

FPGA/ASIC framework and method for requirements-based trust assessment

Described herein are various technologies for metrics-based assessment and trust verification of netlists for hardware logic devices (e.g., ASICs, FPGAs, etc.). A computing system translates a netlist of a hardware logic device into a Boolean network. The computing system generates and assigns metrics to edges of the Boolean network. The metrics comprise a coverage metric, a rare trigger metric, and an influence metric. Based upon the metrics, the computing system assigns the nodes in the Boolean network criticality values. The computing system determines a likelihood of a vulnerability in the netlist based upon the criticality values. The computing can output an indication as to whether the netlist is trusted based upon the determined likelihood of a vulnerability in the netlist.

97 MATHEMATICS AND COMPUTING↗

Economic evaluation of variable renewable energy participation in U.S. ancillary services markets

Variable renewable energy (VRE) is not yet meaningfully participating in U.S. ancillary services (AS) markets. VRE participation in AS markets could provide a new source of revenue for VRE resource owners to offset declining energy and capacity values and a new tool for power system operators to address emerging system constraints. This paper uses a price-taker dispatch model and historical prices to estimate the economic value of standalone and hybrid (battery-paired) VRE participation in AS markets, from the resource owner and electricity system perspectives, in each of the seven U.S. independent system operator and regional transmission organization (ISO/RTO) markets where ancillary service prices are set. Across ISO/RTO markets, average (2015–2019) simulated incremental revenues from power regulation market participation were 0.0–2.9 USD/MWh (+0–15% of revenue without participation) for standalone VRE owners and 1–33 USD/MWh (+1–69%) for hybrid VRE owners. However, ISO/RTO reserve markets are relatively thin and have the potential to become saturated by energy storage projects that are currently in ISO/RTO interconnection queues. In most markets, standalone and hybrid VRE could provide power regulation reserves during periods with high power regulation prices, suggesting that VRE participation in AS markets could have high system value. The analysis highlights the relevance of separate upward and downward power regulation products and indicates that ISOs/RTOs might consider initially focusing on enabling hybrid VRE provision of AS.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Determining strain in amorphous alloys: Uncertainties with analyzing structural changes during deformation

Molecular dynamics simulations were utilized to test the reliability of strain values obtained from diffraction data for noncrystalline alloys. We found that in the case of a one-component system, the strain value obtained from the pair correlation functions underestimates the actual value because of a small degree of atomic relaxations, which minimize the effects of the applied deformation. In the case of multicomponent systems, the different pairs are affected by applied deformation to different extents; moreover, this implies that the strain value determined from diffraction data should depend on the type of scattering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scaling Properties of φ -Meson and Light Charged Hadron Production in Small and Large Systems at PHENIX

Recent results on the identified charged-hadron (π ± , K ± , p, p¯) production vat midrapidity region (|η| < 0.35) have been measured by the PHENIX experiment in p + Al, 3 He + Au, Cu + Au collisions at $\sqrt{s_{NN}}$ = 200 GeV and U + U collisions at $\sqrt{s_{NN}}$ = 193 GeV. These measurements are presented through the invariant transverse-momentum (p T ) and transverse-mass (m T ) spectra for different collision centralities. The averaged freeze-out temperature value for different systems was found to be 166.1 ± 2.2 MeV, and do not exhibit any dependence on the collision centrality and $\langle$N parti $\rangle$ values. The particle ratios of K/π and p/π have been measured in different centrality ranges of large and small collision systems. The values of K/π ratios measured in all considered collision systems were found to be consistent with those measured in p+p collisions. Furthermore, the identified charged-hadron nuclear-modification factors (R AB ) are also presented. Enhancement of proton R AB values over meson R AB values was observed in central 3 He+Au, Cu+Au, and U+U collisions. The proton R AB values measured in p+Al collision system were found to be consistent with R AB values of Φ, π ± , K ± , and π 0 mesons, suggesting that the size of the system produced in p+Al collisions is too small for recombination to cause a noticeable increase in proton production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Power couples: The synergy value of battery-generator hybrids

Battery hybrids - a battery system paired operationally with a generation system - can often provide more value than the individual systems alone. We identify and describe eight value streams that battery hybrids can provide. Additionally, we identify the trends of increasing renewable energy, demand for resilience, need for flexibility, and the increasing economics of hybrid systems of standalone diesel generation as supporting increased battery hybridization in the future.

25 ENERGY STORAGE↗

Approximation solution of Schrodinger equation for Q-deformed Rosen-Morse using supersymmetry quantum mechanics (SUSY QM)

The approximate analytical solution of Schrodinger equation for Q-Deformed Rosen-Morse potential was investigated using Supersymmetry Quantum Mechanics (SUSY QM) method. The approximate bound state energy is given in the closed form and the corresponding approximate wave function for arbitrary l-state given for ground state wave function. The first excited state obtained using upper operator and ground state wave function. The special case is given for the ground state in various number of q. The existence of Rosen-Morse potential reduce energy spectra of system. The larger value of q, the smaller energy spectra of system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Operational Resilience of Nuclear-Renewable Integrated-Energy Microgrids

The increasing prevalence and severity of wildfires, severe storms, and cyberattacks is driving the introduction of numerous microgrids to improve resilience locally. While distributed energy resources (DERs), such as small-scale wind and solar photovoltaics with storage, will be major components in future microgrids, today, the majority of microgrids are backed up with fossil-fuel-based generators. Small modular reactors (SMRs) can form synergistic mix with DERs due to their ability to provide baseload and flexible power. The heat produced by SMRs can also fulfill the heating needs of microgrid consumers. This paper discusses an operational scheme based on distributed control of flexible power assets to strengthen the operational resilience of SMR-DER integrated-energy microgrids. A framework is developed to assess the operational resilience of SMR-DER microgrids in terms of system adaptive real-power capacity quantified as a response area metric (RAM). Month-long simulation results are shown with a microgrid developed in a modified Institute of Electrical and Electronics Engineers (IEEE)-30 bus system. The RAM values calculated along the operational simulation reflect the system resilience in real time and can be used to supervise the microgrid operation and reactor’s autonomous control.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗