Search NASA⌕ Search

SEARCH · Search NASA

Results for “temporal resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

X-ray intravital microscopy for functional imaging in rat hearts using synchrotron radiation coronary microangiography

An X-ray intravital microscopy technique was developed to enable in vivo visualization of the coronary, cerebral, and pulmonary arteries in rats without exposure of organs and with spatial resolution in the micrometer range and temporal resolution in the millisecond range. We have refined the system continually in terms of the spatial resolution and exposure time. X-rays transmitted through an object are detected by an X-ray direct-conversion type detector, which incorporates an X-ray SATICON pickup tube. The spatial resolution has been improved to 6 {mu}m, yielding sharp images of small arteries. The exposure time has been shortened to around 2 ms using a new rotating-disk X-ray shutter, enabling imaging of beating rat hearts. Quantitative evaluations of the X-ray intravital microscopy technique were extracted from measurements of the smallest-detectable vessel size and detection of the vessel function. The smallest-diameter vessel viewed for measurements is determined primarily by the concentration of iodinated contrast material. The iodine concentration depends on the injection technique. We used ex vivo rat hearts under Langendorff perfusion for accurate evaluation. After the contrast agent is injected into the origin of the aorta in an isolated perfused rat heart, the contrast agent is delivered directly into the coronary arteries with minimum dilution. The vascular internal diameter response of coronary arterial circulation is analyzed to evaluate the vessel function. Small blood vessels of more than about 50 {mu}m diameters were visualized clearly at heart rates of around 300 beats/min. Vasodilation compared to the control was observed quantitatively using drug manipulation. Furthermore, the apparent increase in the number of small vessels with diameters of less than about 50 {mu}m was observed after the vasoactive agents increased the diameters of invisible small blood vessels to visible sizes. This technique is expected to offer the potential for direct investigation of mechanisms of vascular dysfunctions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-phase air-water stratified flow measurement using ultrasonic techniques

In this paper, a time resolved ultrasound system was developed for investigating two-phase air-water stratified flow. The hardware of the system includes a pulsed wave transducer, a pulser/receiver, and a digital oscilloscope. The time domain cross correlation method is used to calculate the velocity profile along ultrasonic beam. The system is able to provide velocities with spatial resolution of around 1mm and the temporal resolution of 200μs. Experiments were carried out on single phase water flow and two-phase air-water stratified flow. For single phase water flow, the flow rates from ultrasound system were compared with those from electromagnetic flow (EM) meter, which showed good agreement. Then, the experiments were conducted on two-phase air-water stratified flow and the results were given. Compared with liquid height measurement from conductance probe, it indicated that the measured velocities were explainable.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurements of DIII-D poloidal field by fiber-optic pulsed polarimetry

A new technique for measuring the spatial and temporal structure of the poloidal field is presented, whereby the magnetic field causes the polarization of light traveling through an optical fiber to rotate via the Faraday effect by an amount proportional to the strength of the field oriented along the fiber. In fiber optic pulsed polarimetry, changes in the polarization of the backscatter light from the fiber are detected, thereby permitting measurement of the field as a function of position along the fiber. In this proof-of-principle experiment, specially prepared single-mode fibers with weak fiber Bragg gratings were installed in the poloidal direction on the outside of the thermal blanket on DIII-D. Light at 532 nm from a mode-locked Nd:YAG laser was injected into the optical fibers. The laser repetition rate was 895 kHz with a pulse length of <10 ps, resulting in ~1 μs temporal resolution. A photodetector system measured the Stokes polarization components necessary to determine the amount of polarization rotation. For this experiment, bandwidth limitations of the detectors resulted in a spatial resolution of ≈2 cm. The measured temporal and spatial distributions of the poloidal field are consistent with inductive probe measurements and Elastodynamic Finite Integration Technique reconstructions of the spatial distribution. Furthermore, this demonstrates the ability of this technique to provide real-time detection of the temporal and spatial variations of the poloidal field. Besides revealing more detailed information about the plasma, this new diagnostic capability can also help in detecting instabilities in real time, thereby enabling enhanced machine protection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A benchtop shock physics laboratory: Ultrafast laser driven shock spectroscopy and interferometry methods

Common Ti:sapphire chirped pulse amplified laser systems can be readily adapted to be both a generator of adjustable pressure shock waves and a source for multiple probes of the ensuing ultrafast shock dynamics. Here, we detail experimental considerations for optimizing the shock generation, interferometric characterization, and spectroscopic probing of shock dynamics with visible and mid-infrared transient absorption. While we have reported results using these techniques elsewhere, in this work we detail how the spectroscopies are integrated with the shock and interferometry experiment. The interferometric characterization uses information from beams at multiple polarizations and angles of incidence combined with thin film equations and shock dynamics to determine the shock velocity, particle velocity, and shocked refractive index. Visible transient absorption spectroscopy uses a white light supercontinuum in a reflection geometry, synchronized to the shock wave, to time resolve shock-induced changes in visible absorption such as changes to electronic structure or strongly absorbing products and intermediates due to reaction. Mid-infrared transient absorption spectroscopy uses two color filamentation supercontinuum generation combined with a simple thermal imaging microbolometer spectrometer to enable broadband single shot detection of changes in the vibrational spectra. These methods are reflected here in the study of shock dynamics at stresses from 5 to 30 GPa in organic materials and from a few GPa to >70 GPa in metals with spatial resolution of a few micrometers and temporal resolution of a few picoseconds. This experiment would be possible to replicate in any ultrafast laser laboratory containing a single bench top commercial chirped pulse amplification laser system.

47 OTHER INSTRUMENTATION↗

Installation of a solid state neutral particle analyzer array on mega ampere spherical tokamak upgrade

A compact solid state neutral particle analyzer (SSNPA) diagnostic, previously installed at NSTX-U, has been moved to MAST-U and successfully operated in the first physics campaign (MU01). The SSNPA operates by detecting the flux of fast neutral particles produced by charge exchange (CX) reactions to diagnose the fast ion distribution. The diagnostic consists of three 16-channel sensors, which provide a radial view of the plasma and have a sightline intersection with the South–South neutral beam line. From this radial geometry, active CX signals from mostly trapped particles are observed. Each channel has a spatial resolution of 3–4 cm, a temporal resolution of 200 kHz, and an average pitch angle resolution of a few degrees. The three-sensor configuration allows for coarse energy resolution of the CX signals; each sensor sees similar sightlines but different filter thicknesses alter the energy cutoffs by known amounts. Experimental data show that all channels are collecting data as intended. The signal to noise ratio is typically around 15. Preliminary data analysis shows a correlation between the SSNPA signal and magnetohydrodynamic activity in the plasma as expected.

Instruments & Instrumentation↗

On the limits of observing motion in time-resolved X-ray scattering

Limits on the ability of time-resolved X-ray scattering (TRXS) to observe harmonic motion of amplitude, A and frequency, ω 0 , about an equilibrium position, R 0 , are considered. Experimental results from a TRXS experiment at the LINAC Coherent Light Source are compared to classical and quantum theories that demonstrate a fundamental limitation on the ability to observe the amplitude of motion. These comparisons demonstrate dual limits on the spatial resolution through Q max and the temporal resolution through ω max for observing the amplitude of motion. In the limit where ωmax ≈ ω 0 , the smallest observable amplitude of motion is A = 2π/Q max . In the limit where ω max ≥2ω 0 , A≤2π/Q max is observable provided there are sufficient statistics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Distributed Fiber Optic Sensing to Identify Locations of Resistive Transitions in REBCO Conductors and Magnets

High-temperature superconductors such as REBa 2 Cu 3 O 7-x (REBCO, RE = rare earth) can generate strong magnetic fields that are promising for applications in particle accelerators and compact fusion reactors. Traditionally, voltage taps are installed in superconducting magnets to measure the voltage signals due to resistive transitions. The voltage-tap-based diagnostics is important for the development of magnet technology as it can help pinpoint the locations in the magnet windings that limit the magnet performance. The architecture of the multi-tape REBCO cable such as CORC wires, however, makes it difficult to apply the voltage-tap-based diagnostics to identify the locations of resistive transitions. Distributed fiber optic sensing (DFOS) has the potential to address this issue. In this paper, we report the measurements of thermal strain along a CORC wire based on optical frequency domain reflectometry with a maximum spatial resolution of 0.65 mm and a temporal resolution of 10 Hz. The optical fiber is co-wound with the CORC wire that is epoxy impregnated. During the test, current was increased until a resistive transition occurred in the conductor. The spectrum shift of the reflected light along the fiber was recorded. The results suggested that with proper thermal isolation from the cryogen, DFOS can be used to identify the locations of resistive transitions in CORC wires and magnets. In conclusion, the results will allow a better understanding of the causes of resistive transitions in REBCO conductors and magnets, which will help improve the REBCO magnet technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TU-F-17A-03: An Analytical Respiratory Perturbation Model for Lung Motion Prediction

Purpose: Breathing irregularity is common, causing unreliable prediction in tumor motion for correlation-based surrogates. Both tidal volume (TV) and breathing pattern (BP=ΔVthorax/TV, where TV=ΔVthorax+ΔVabdomen) affect lung motion in anterior-posterior and superior-inferior directions. We developed a novel respiratory motion perturbation (RMP) model in analytical form to account for changes in TV and BP in motion prediction from simulation to treatment. Methods: The RMP model is an analytical function of patient-specific anatomic and physiologic parameters. It contains a base-motion trajectory d(x,y,z) derived from a 4-dimensional computed tomography (4DCT) at simulation and a perturbation term Δd(ΔTV,ΔBP) accounting for deviation at treatment from simulation. The perturbation is dependent on tumor-specific location and patient-specific anatomy. Eleven patients with simulation and treatment 4DCT images were used to assess the RMP method in motion prediction from 4DCT1 to 4DCT2, and vice versa. For each patient, ten motion trajectories of corresponding points in the lower lobes were measured in both 4DCTs: one served as the base-motion trajectory and the other as the ground truth for comparison. In total, 220 motion trajectory predictions were assessed. The motion discrepancy between two 4DCTs for each patient served as a control. An established 5D motion model was used for comparison. Results: The average absolute error of RMP model prediction in superior-inferior direction is 1.6±1.8 mm, similar to 1.7±1.6 mm from the 5D model (p=0.98). Some uncertainty is associated with limited spatial resolution (2.5mm slice thickness) and temporal resolution (10-phases). Non-corrected motion discrepancy between two 4DCTs is 2.6±2.7mm, with the maximum of ±20mm, and correction is necessary (p=0.01). Conclusion: The analytical motion model predicts lung motion with accuracy similar to the 5D model. The analytical model is based on physical relationships, requires no training, and therefore is potentially more resilient to breathing irregularities. On-going investigation introduces airflow into the RMP model for improvement. This research is in part supported by NIH (U54CA137788/132378). AY would like to thank MSKCC summer medical student research program supported by National Cancer Institute and hosted by Department of Medical Physics at MSKCC.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRA-09: Towards an Optimal Breath-Holding Procedure for Radiotherapy: Differences in Organ Motion During Inhalation and Exhalation Breath-Holds

Purpose: Breath-holding (BH) is often used to reduce organ motion during radiotherapy. The aim of this study was to determine the differences in pancreatic and diaphragmatic motion during BH between inhalation and exhalation BHs with variable lung volumes and to investigate whether motion increases/decreases during BH. Methods: Sixteen healthy volunteers were asked to perform four different 60-second BHs, from fully inflated to fully deflated lungs (i.e. lung volumes of: 100%, ∼70%, ∼30% and 0% of inspiratory capacity) three times (total of 192 BHs). During each BH, we obtained single-slice (coronal) magnetic-resonance scans with spatial resolution 0.93×0.93×8.0 mm3 and temporal resolution 0.6 s. We used 2-dimensional image correlation to obtain the motion of pancreatic head and diaphragm during BH. Motion magnitude in inferior-superior direction was obtained by determining the maximum displacement during BH. Results: Pancreatic and diaphragmatic drifts occurred during BH and were mostly in the superior direction. We observed significantly smaller pancreatic and diaphragmatic motion magnitudes in inferior-superior direction during exhalation BHs (BH{sub 30%} and BH{sub 0%}) compared to inhalation BHs (BH{sub 100%} and BH{sub 70%}). The mean motion magnitudes of the pancreatic head were 7.0, 6.5, 4.4 and 4.2 mm during BH{sub 100%}, BH{sub 70%}, BH{sub 30%} and BH{sub 0%}, respectively, and mean BH durations were 59.9, 59.1, 59.0 and 52.7 s. For the diaphragm, mean motion magnitudes were 9.8, 9.0, 5.6 and 4.3 mm, respectively. When considering 30-second BHs, as often used in the clinic, the motion was most pronounced during the first 10 s and excluding these from the analysis (yielding an effective BH period of 20 s) significantly reduced (P≤0.002) organ motion. Conclusion: Organ motion was significantly smaller during exhalation BHs compared to inhalation BHs. Also, motion was largest at the start of BH. Hence, waiting for 10 s may significantly decrease motion of the pancreas and diaphragm during treatment.

60 APPLIED LIFE SCIENCES↗

Observing clouds in 4D with multi-view stereo photogrammetry

We report that newly installed stereo cameras ringing the Southern Great Plains (SGP) Atmospheric Radiation Measurement (ARM) site in Oklahoma are providing a 4D gridded view of shallow clouds. Six digital cameras have been installed in pairs at a distance of 6 kilometers from the site and with a spacing of 500 meters between cameras in a pair. These pairs of cameras provide stereoscopic views of shallow clouds from all sides; when these data are combined, they allow for a complete stereo reconstruction. The result – the Clouds Optically Gridded by Stereo (COGS) product – is a 4D grid of cloudiness covering a 6 km × 6 km × 6 km cube at a spatial resolution of 50 meters and a temporal resolution of 20 seconds. This provides an unprecedented set of data on the sizes, lifetimes, and lifecycles of shallow clouds. Lastly, this type of information is critical for developing cloud macrophysical schemes for the next generation of weather and climate models.

47 OTHER INSTRUMENTATION↗

Dataset Repository for Investigating Suicide Risk Using Social and Environmental Determinants of Health

Suicide is frequently modeled as a function of genetics and environment, where the latter refers to factors other than direct biological consequences, such as air quality, financial level, social connectivity, transportation and food access, and homelessness status. According to the World Health Organization, clean air, a stable climate, adequate water, sanitation and hygiene, safe chemical use, radiation protection, healthy and safe workplaces, sound agricultural practices, health-supportive cities and built environments, and a preserved natural environment are all prerequisites for good health. Understanding the relationships between these determinants and mental health outcomes requires standardized data that can be included in healthcare programs and health outcome models. There is a wealth of publicly available data on social and environmental factors provided by various US organizations that can benefit the design of health care systems and public health interventions, as well as improve our comprehension of factors that impact health. Such information would not only help improve the understanding of individual and community risk but also identify new risk factors that have not previously been therapeutically targeted, especially in terms of their impact on mental health. However, curating and standardizing such datasets is challenging because they are often recorded at numerous geographical and temporal resolutions and with varying spatial and temporal granularities. To address this challenge, we launched an endeavor in conjunction with the Veterans Health Administration to collect publicly available socioeconomic and environmental determinants of health statistics in the US. In this manuscript, we describe a social and environmental determinants of health (SEDH) datasets repository, data curation documentation, and a pipeline framework for data generation; This effort started in 2020, when we began constructing a scalable pipeline to automate the download, extraction, preparation, analysis, and production of datasets. These datasets have been made available to the VHA and may be shared upon agreement with collaborating organizations.

60 APPLIED LIFE SCIENCES↗

Development of backlighting sources for a Compton Radiography diagnostic of Inertial Confinement Fusion targets

An important diagnostic tool for inertial confinement fusion is time-resolved imaging of the dense cold fuel surrounding the hot spot. Here we report on the source and diagnostic development of hard x-ray radiography and on the first radiographs of direct drive implosions obtained at photon energies up to about 100keV, where the Compton effect is the dominant contributor to the shell opacity. The radiographs of direct drive, plastic shell implosions obtained at the OMEGA laser facility have a spatial resolution of {approx}10um and a temporal resolution of {approx}10ps. This novel Compton Radiography is an invaluable diagnostic tool for Inertial Confinement Fusion targets, and will be integrated at the National Ignition Facility (NIF).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal modeling of three lakes within the continuous permafrost zone in Alaska using the LAKE 2.0 model

Abstract. Lakes in the Arctic are important reservoirs of heat with much lower albedo in summer and greater absorption of solar radiation than surrounding tundra vegetation. In the winter, lakes that do not freeze to their bed have a mean annual bed temperature >0 ∘C in an otherwise frozen landscape. Under climate warming scenarios, we expect Arctic lakes to accelerate thawing of underlying permafrost due to warming water temperatures in the summer and winter. Previous studies of Arctic lakes have focused on ice cover and thickness, the ice decay process, catchment hydrology, lake water balance, and eddy covariance measurements, but little work has been done in the Arctic to model lake heat balance. We applied the LAKE 2.0 model to simulate water temperatures in three Arctic lakes in northern Alaska over several years and tested the sensitivity of the model to several perturbations of input meteorological variables (precipitation, shortwave radiation, and air temperature) and several model parameters (water vertical resolution, sediment vertical resolution, depth of soil column, and temporal resolution). The LAKE 2.0 model is a one-dimensional model that explicitly solves vertical profiles of water state variables on a grid. We used a combination of meteorological data from local and remote weather stations, as well as data derived from remote sensing, to drive the model. We validated modeled water temperatures with data of observed lake water temperatures at several depths over several years for each lake. Our validation of the LAKE 2.0 model is a necessary step toward modeling changes in Arctic lake ice regimes, lake heat balance, and thermal interactions with permafrost. The sensitivity analysis shows us that lake water temperature is not highly sensitive to small changes in air temperature or precipitation, while changes in shortwave radiation and large changes in precipitation produced larger effects. Snow depth and lake ice strongly affect water temperatures during the frozen season, which dominates the annual thermal regime of Arctic lakes. These findings suggest that reductions in lake ice thickness and duration could lead to more heat storage by lakes and enhanced permafrost degradation.

Clark, Jason A. (ORCID:0000000248105261)↗

Clouds Optically Gridded by Stereo COGS product

COGS product is a 4D grid of cloudiness covering a 6 km × 6 km × 6 km cube centered at the central facility of SGP site at a spatial resolution of 50 meters and a temporal resolution of 20 seconds. The dimensions are X, Y, Z, and time, where X,Y, Z, correspond to east-west, north-south, and altitude of the grid point, respectively. COGS takes on values 0, 1, and -1 denoting "cloud", "no cloud", and "not available".

54 ENVIRONMENTAL SCIENCES↗

Stereographic observations from geosynchronous satellites - An important new tool for the atmospheric sciences

Observations of cloud geometry using scan-synchronized stereo geostationary satellites having images with horizontal spatial resolution of approximately 0.5 km, and temporal resolution of up to 3 min are presented. The stereo does not require a cloud with known emissivity to be in equilibrium with an atmosphere with a known vertical temperature profile. It is shown that absolute accuracies of about 0.5 km are possible. Qualitative and quantitative representations of atmospheric dynamics were shown by remapping, display, and stereo image analysis on an interactive computer/imaging system. Applications of stereo observations include: (1) cloud top height contours of severe thunderstorms and hurricanes, (2) cloud top and base height estimates for cloud-wind height assignment, (3) cloud growth measurements for severe thunderstorm over-shooting towers, (4) atmospheric temperature from stereo heights and infrared cloud top temperatures, and (5) cloud emissivity estimation. Recommendations are given for future improvements in stereo observations, including a third GOES satellite, operational scan synchronization of all GOES satellites and better resolution sensors.

Hasler, A. F.↗

Radiometer mission requirements for large space antenna systems

Requirements are defined for Earth observational microwave radiometry using large space antenna systems with apertures in the 50 to 200 meter range. General Earth observational needs, specific measurement requirements, orbital mission guidelines and constraints, and general radiometric requirements are defined. Specific measurements include soil moisture, water surface temperature, water roughness, ice boundaries, salinity, and water pollutants. Measurements with 10 to 1 km spatial resolution and 3 to 1 day temporal resolution are required.

Keafer, L. S., Jr.↗

Investigation of breadboard temperature profiling system for SSME fuel preburner diagnostics

The feasibility of measuring temperatures in the space shuttle main engine (SSME) fuel preburner using spontaneous Raman scattering from molecular hydrogen was studied. Laser radiation is transmitted to the preburner through a multimode optical fiber. Backscattered Raman-shifted light is collected and focused into a second fiber which connects to a remote-located spectrograph and a mutlichannel optical detector. Optics collimate and focus laser light from the transmitter fiber defining the probe volume. The high pressure, high temperature preburner environment was simulated by a heated pressure cell. Temperatures determined by the distribution of Q-branch co-vibrational transitions demonstrate precision and accuracy of 3%. It is indicated heat preburner temperatures can be determined with 5% accuracy with spatial resolution less than 1 cm and temporal resolution of 10 millisec at the nominal preburner operation conditions.

Shirley, J. A.↗

Measurements of temperature, density, pressure, and their fluctuations in supersonic turbulence using laser-induced fluorescence

A laser-induced fluorescence method has been developed that provides simultaneous measurements of temperature, density, and their fluctuations owing to turbulence in unheated compressible flows. Pressure and its fluctuations are also deduced using the equation of state. Fluorescence is induced in nitric oxide that has been seeded into a nitrogen flow in concentrations of 100 ppm. Measurements are obtained from each laser pulse, with a spatial resolution of 1 mm and a temporal resolution of 125 ns. The method was applied to a supersonic, turbulent, boundary-layer flow with a free-stream Mach number of 2. For stream conditions in the range from 150-300 K and 0.3-1 atm, temperature is measured with an uncertainty of approximately 1 percent rms, while density and pressure uncertainties are approximately 2 percent rms.

Gross, K. P.↗