Search NASASearch

SEARCH · Search NASA

Results for “thermal vacuum testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

856 records · Page 28

Advanced nickel-hydrogen spacecraft battery development

Eagle-Picher currently has several advanced nickel-hydrogen (NiH2) cell component and battery designs under development including common pressure vessel (CPV), single pressure vessel (SPV), and dependent pressure vessel (DPV) designs. A CPV NiH2 battery, utilizing low-cost 64 mm (2.5 in.) cell diameter technology, has been designed and built for multiple smallsat programs, including the TUBSAT B spacecraft which is currently scheduled (24 Nov. 93) for launch aboard a Russian Proton rocket. An advanced 90 mm (3.5 in.) NiH2 cell design is currently being manufactured for the Space Station Freedom program. Prototype 254 mm (10 in.) diameter SPV batteries are currently under construction and initial boilerplate testing has shown excellent results. NiH2 cycle life testing is being continued at Eagle-Picher and IPV cells have currently completed more than 89,000 accelerated LEO cycles at 15% DOD, 49,000 real-time LEO cycles at 30 percent DOD, 37,800 cycles under a real-time LEO profile, 30 eclipse seasons in accelerated GEO, and 6 eclipse seasons in real-time GEO testing at 75 percent DOD maximum. Nickel-metal hydride battery development is continuing for both aerospace and electric vehicle applications. Eagle-Picher has also developed an extensive range of battery evaluation, test, and analysis (BETA) measurement and control equipment and software, based on Hewlett-Packard computerized data acquisition/control hardware.

Coates, Dwaine K.

Final Report Document: Microgravity Medical Eyewash B

Senior Capstone Design Team 15 has been commissioned by the National Aeronautics and Space Administration (NASA) to redesign the current microgravity eye wash station. The current design exhibits four primary limitations: single-use operation, excessive mass and volume, operational complexity requiring coordination with external systems, and dependence on frequent Earth resupply missions. Our updated eyewash design will be deployed on long-range space missions that could last multiple years. Based on these and other requirements from our customer, we have developed our updated eyewash design. Our compact, single-eye system uses capillary-driven flow and a free-floating water ball. This design allows us to eliminate pumps and bulky tubing, decreasing the mass and volume of the overall system. The containment eyecup is held to the astronaut's face with a strap, and a silicone seal prevents leakage while improving user comfort. Contaminated water is contained within a disposal bag containing wicking material to pull it back out of the eyecup after washing the eye. This system is reusable, efficient, and easy to activate quickly. We evaluated our design through calculations, microfluidic testing, and user try-on testing to verify our requirements. Our work demonstrated that steady-state flow was capable with our capillary framework, achieving 1.31 L/min. The prototype construction confirmed mass and volume reductions, and try-on-testing evaluated the ability to put on the system quickly. Almost all major design requirements were achieved, and water loss could be validated by testing in microgravity. Our design went through a number of iterations to reach the final solution presented in this report. These changes were driven by our testing and collaboration from each member of the team. Updated models optimized tube placement and geometry of the eyecup to better direct flow as it pools across the eye. Changes to our tubing bends improved capillary efficiency and increased the flow rate we were capable of achieving. And improved bracket placements adjusted the fit, comfort, and seal of the eyecup to the astronaut's face. Our capillary-based eyewash system is technically feasible and has been theoretically validated to operate effectively in microgravity conditions. Testing and analysis indicate that it can meet or exceed the required performance metrics, including flow rate and safety constraints. Overall, the design represents a viable alternative to current ISS-dependent eyewash systems for future space missions.

Jeffrey Allen

Nickel-hydrogen battery design for the Transporter Energy Storage Subsystem (TESS)

Information is given in viewgraph form on nickel hydrogen battery design for the transporter energy storage subsystem (TESS). Information is given on use in the Space Station Freedom, the launch configuration, use in the Mobile Servicing Center, battery design requirements, TESS subassembley design, proof of principle testing of a 6-cell battery, possible downsizing of TESS to support the Mobile Rocket Servicer Base System (MBS) redesign, TESS output capacity, and cell testing.

Lapinski, John R.

Bend Properties of Sapphire Fibers at Elevated Temperatures: Bend Survivability - 1

The effect of temperature on the bend radius that a c-axis-oriented sapphire fiber can withstand was determined for fibers of various diameter. Bend stress rupture tests were performed for times of 1-100 h and temperatures of 300-1700 C. Fibers would survive the bend test undeformed, would fracture or would deform. The bend survival radius was determined to be the radius above which no fibers fractured or deformed for a given time-temperature treatment. It was found that the ability of fibers to withstand curvature decreases substantially with time and increasing temperature and that fibers of smaller diameter (46-83 micron) withstood smaller bend radii than would be expected from just a difference in fiber diameter when compared with the bend results of the fibers of large diameter (144 micron). This was probably due to different flaw populations, causing high temperature bend failure for the tested sapphire fibers of different diameters.

Sapphire

Update of the IUE battery in-flight performance

The in-flight performance data of two 17-cell, 6-ampere-hour nickel cadmium spacecraft batteries are presented covering 22 months of operation. Fluctuations in the battery voltage and the battery temperature are presented for spacecraft movement throughout a beta range of 0 to 130 deg. The battery discharge voltages during the peak eclipse seasons, daily seasons, and daily eclipse periods are noted. Finally, the spacecraft data are compared to data from a 6-ampere-hour test pack and test flight data.

Tiller, S. E.

Synthetic battery cycling

The use of interactive computer graphics is suggested as an aid in battery system development. Mathematical representations of simplistic but fully representative functions of many electrochemical concepts of current practical interest will permit battery level charge and discharge phenomena to be analyzed in a qualitative manner prior to the assembly and testing of actual hardware. This technique is a useful addition to the variety of tools available to the battery system designer as he bridges the gap between interesting single cell life test data and reliable energy storage subsystems.

Thaller, L. H.

Galileo Li/SO sub 2 battery modules program update

In order to meet the power needs of NASA's Galileo Probe, the Li/SO2 high rate D cells used in the battery modules have undergone some design changes, as upgrading of hardware quality requirements, and significant testing. A description of the design changes and the cell test data that are of a general nature is presented here. This data includes capacities, open circuit voltages, and internal resistance comparisons. A significant data base was built up over the years and continues to grow.

Smith, R. A.

A Predictive Bubble Point Pressure Model for Porous Liquid Acquisition Device Screens

This article presents a simplified model for porous screen channel liquid acquisition devices based on a maximum bubble point pressure method from Adamson and Gast (1997). To validate the model, three 304 stainless steel (325 × 2300, 450 × 2750, and 510 × 3600) mesh samples were tested in methanol, acetone, isopropyl alcohol, and water. Screen pores are estimated based on analysis from scanning electron microscopy, historical data, and current test data. Results show that the bubble point pressure is proportional to the surface tension of the fluid only when accounting for nonzero contact angles. The previous assumption that bubble point pressure scales inversely with effective pore diameter is shown to be invalid, as the second finest 450 × 2750 produced the highest bubble point of the three screens. The simplified bubble point model can be used to make predictions for any pure fluid when pore diameters are based on bubble point tests and not SEM analysis.

Liquid Acquisition Device

Effects of Ground Boards on Acoustic Signals

Acoustic ground boards are used to provide hard reflective surfaces for microphones when taking outdoor measurements. These boards also have a wide variety of potential impacts on the signal received by the microphones. A comprehensive experimental campaign was completed in which various ground board and microphone configurations were tested to determine their effects on the acoustic signals returned by the microphones. Comparisons are made between these setups and a free-field reference case. Normal impedance testing on various combinations of sand, plywood, and ground board material was also completed.

Mark CAnderson

Properties of a Ni19.5Pd30Ti50.5 High-Temperature Shape Memory Alloy in Tension and Compression

Potential applications involving high-temperature shape memory alloys have been growing in recent years. Even in those cases where promising new alloys have been identified, the knowledge base for such materials contains gaps crucial to their maturation and implementation in actuator and other applications. We begin to address this issue by characterizing the mechanical behavior of a Ni 19.5 Pd 30 Ti 50.5 high-temperature shape memory alloy in both uniaxial tension and compression at various temperatures. Differences in the isothermal uniaxial deformation behavior were most notable at test temperatures below the martensite finish temperature. The elastic modulus of the material was very dependent on strain level; therefore, dynamic Young’s Modulus was determined as a function of temperature by an impulse excitation technique. More importantly, the performance of a thermally activated actuator material is dependent on the work output of the alloy. Consequently, the strain-temperature response of the Ni 19.5 Pd 30 Ti 50.5 alloy under various loads was determined in both tension and compression and the specific work output calculated and compared in both loading conditions. It was found that the transformation strain and thus, the specific work output were similar regardless of the loading condition. Also, in both tension and compression, the strain-temperature loops determined under constant load conditions did not close due to the fact that the transformation strain during cooling was always larger than the transformation strain during heating. This was apparently the result of permanent plastic deformation of the martensite phase with each cycle. Consequently, before this alloy can be used under cyclic actuation conditions, modification of the microstructure or composition would be required to increase the resistance of the alloy to plastic deformation by slip.

High-Temperature Shape Memory Alloy

Space Telescope Optical Telescope Assembly/Scientific Instruments: Phase B - Preliminary Design and Program Definition Study: Volume 2A - Planetary Camera

Development of the F/48, F/96 Planetary Camera for the Large Space Telescope is discussed. Instrument characteristics, optical design, and CCD camera submodule thermal design are considered along with structural subsystem and thermal control subsystem. Weight, electrical subsystem, and support equipment requirements are also included.

Itek Optical Systems

Nickel-hydrogen battery state of charge during low rate trickle charging

Battery temperature increase, due to low rate trickle charging, has been determined experimentally, using a six cell battery module in a test setup simulating the anticipated AXAF-1 prelaunch environment. Test results indicate trickle charge rates less than or equal to the self discharge rate do not increase dissipation beyond that due to the self discharge. Significant trickle charge rates (approximately C/500) result in battery temperatures only a few degrees (F) higher than those observed during periods of open circuit stand.

Lurie, C.

Summary of LDEF battery analyses

Tests and analyses of NiCd, LiSO2, and LiCf batteries flown on the Long Duration Exposure Facility (LDEF) includes results from NASA, Aerospace, and commercial labs. The LiSO2 cells illustrate six-year degradation of internal components acceptable for space applications, with up to 85 percent battery capacity remaining on discharge of some returned cells. LiCf batteries completed their mission, but lost any remaining capacity due to internal degradation. Returned NiCd batteries tested an GSFC showed slight case distortion due to pressure build up, but were functioning as designed.

Johnson, Chris

Bipolar Nickel-Metal Hydride Battery Development Project

This paper reviews the development of the Electro Energy, Inc.'s bipolar nickel metal hydride battery. The advantages of the design are that each cell is individually sealed, and that there are no external cell terminals, no electrode current collectors, it is compatible with plastic bonded electrodes, adaptable to heat transfer fins, scalable to large area, capacity and high voltage. The design will allow for automated flexible manufacturing, improved energy and power density and lower cost. The development and testing of the battery's component are described. Graphic presentation of the results of many of the tests are included.

Cole, John H.

Reliability Modeling of Brittle Anisotropic Materials

A significant effort is being made to develop testing and design methodologies that will account for the lack of ductility and the strength anisotropy exhibited by brittle single crystals such as NiAl. The present approach is to modify existing test methods and brittle design methodologies, such as those applied to ceramics and glasses, and to experimentally verify the results. This paper focuses on the basic materials properties and strength behavior of a NiAl single crystal alloy and the development of a reliability model for the design of components subjected to multiaxial stresses.

Conceivably

Columbia Accident Investigation Board Report: Volume Four

Volume IV of the Report contains appendices that were not cited in Volume I. These consist of documents produced by NASA and other organizations, which were provided to the Columbia Accident Investigation Board in support of its inquiry into the February 1, 2003 destruction of the Space Shuttle Columbia. The documents are compiled in this volume in the interest of establishing a complete record, but they do not necessarily represent the views of the Board. Volume I contains the Board's findings, analysis, and recommendations. The documents in Volume III through V are also contained in their original color format on the DVD disc in the back of Volume II. Volumes II – VI contain a number of conclusions and recommendations, several of which were adopted by the Board in Volume I. The other conclusions and recommendations drawn in Volumes II – VI do not necessarily reflect the opinion of the Board, but are included for the record. When there is conflict, Volume I takes precedence.

NASA

Cryogenic Mixed Mode I – Mode II Fracture Toughness of Various Polymer Composite Materials

The present study investigates the mixed mode interlaminar fracture toughness of six polymer matrix composite materials at both room temperature and cryogenic liquid nitrogen temperature. The single leg bending test employed gives a mix of Mode I (opening) and Mode II (in-plane shearing) cracking. The tested thermoplastic-matrix composites were shown to have total mixed mode toughnesses 3.1–4.3 times higher than those of representative thermoset resin composites.

Carbon fiber

High Temperature - Thin Film Strain Gages Based on Alloys of Indium Tin Oxide

A stable, high temperature strain gage based on reactively sputtered indium tin oxide (ITO) was demonstrated at temperatures up to 1050 C. These strain sensors exhibited relatively large, negative gage factors at room temperature and their piezoresistive response was both linear and reproducible when strained up to 700 micro-in/in. When cycled between compression and tension, these sensors also showed very little hysteresis, indicating excellent mechanical stability. Thin film strain gages based on selected ITO alloys withstood more than 50,000 strain cycles of +/- 500 micro-in/in during 180 hours of testing in air at 1000 C, with minimal drift at temperature. Drift rates as low as 0.0009%/hr at 1000 C were observed for ITO films that were annealed in nitrogen at 700 C prior to strain testing. These results compare favorably with state of the art 10 micro-m thick PdCr films deposited by NASA, where drift rates of 0.047%/hr at 1050 C were observed. Nitrogen annealing not only produced the lowest drift rates to date, but also produce the largest dynamic gage factors (G = 23.5). These wide bandgap, semiconductor strain sensors also exhibited moderately low temperature coefficients of resistance (TCR) at temperatures up to 1100 C, when tested in a nitrogen ambient. A TCR of +230 ppm/C over the temperature range 200 C < T < 500 C and a TCR of -469 ppm/C over the temperature range 600 C < T < 1100 C was observed for the films tested in nitrogen. However, the resistivity behavior changed considerably when the same films were tested in oxygen ambients. A TCR of -1560 ppm/C was obtained over the temperature range of 200 C < T < 1100 C. When similar films were protected with an overcoat or when ITO films were prepared with higher oxygen contents in the plasma, two distinct TCR's were observed. At T < 800 C, a linear TCR of -210 ppm/C was observed and at T > 800 C, a linear TCR of -2170 DDm/C was observed. The combination of a moderately low TCR and a relatively large gage factor make these semiconducting oxide films promising candidates for the active strain elements in high temperature thin film strain gages, particularly in applications where static strain measurement is desired.

Otto J Gregory