Search NASA⌕ Search

SEARCH · Search NASA

Results for “tritium processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Vadose Zone Model for B-3A/B Pond for Composite Analysis

The objectives of the vadose modeling for the updated Hanford Site composite analysis (CA) are to simulate the flow and transport of water and radionuclide releases from the surface to the water table and to provide radionuclide transfer rates for the plateau to river (P2R) model, version 8.3 (CP-57037, Model Package Report: Plateau to River Groundwater Model, Version 8.3). Water additions include natural recharge and water discharged to the ground as a result of industrial processes associated with Hanford Site operations. Contaminant sources include radionuclides in water discharged to the ground during operations and radionuclides disposed “dry” in solid waste burial grounds or other means. The following 16 radionuclides were selected for this modeling effort; carbon-14 (C-14), chlorine-36 (Cl-36), tritium (H-3), iodine-129 (I-129), neptunium-237 (Np-237), rhenium-187 (Re-187), strontium-90 (Sr-90), technetium-99 (Tc-99), uranium-232 (U-232), uranium-233 (U-233), uranium-234 (U-234), uranium-235 (U-235), uranium-236 (U-236), uranium-238 (U-238), radium-226 (Ra-226), and thorium-230 (Th-230). The simulation time starts in 1943 and ends at 12070, which is 10,000 years after assumed Hanford Site closure in 2070. The parallel version of the Subsurface Transport Over Multiple Phases (STOMP) simulator officially named the exascale Subsurface Transport Over Multiple Phases (eSTOMP), is used to simulate flow and transport for the vadose models. The documentation for the STOMP code is comprehensive. The theoretical and numerical approaches applied in the STOMP code are documented in a published theory guide (PNNL-12030, STOMP Subsurface Transport Over Multiple Phases Version 2.0 Theory Guide). The code has undergone a rigorous verification procedure against analytical solutions, laboratory-scale experiments, and field-scale demonstrations. The application guide (PNNL-11216, STOMP Subsurface Transport Over Multiple Phases Application Guide) provides instructive examples in the application of the code to classical groundwater problems. The user’s guide (PNNL-15782, STOMP: Subsurface Transport Over Multiple Phases Version 4.0: User’s Guide) describes the general use, input file formatting, compilation, and execution of the code. The primary output of the vadose zone modeling is radionuclide transfer rates to the groundwater for input into the P2R model. The rates will be summed over the 100 by 100 m P2R grid cells that fall within the vadose zone model source domain. The Hanford Site Central Plateau was subdivided into 26 individual vadose zone models, with 13 in the 200 East Area and 13 in the 200 West Area. Waste sites that have a completed performance assessment (PA) or past-leak analysis were not included as sources of radionuclides. Instead the vadose zone to groundwater transfer rates of the Environmental Restoration Disposal Facility, Integrated Disposal Facility, US Ecology, and Waste Management Area C (WMA C) PAs and the past-leak analysis for WMA C were used as direct input to the P2R model. Each of the vadose zone models is documented in separate environmental calculation files (ECFs). This ECF describes the B-3A/B Ponds model. The scope of this ECF is to document the development and results of the B-3 A/B Ponds vadose zone model. CP-63515, Model Package Report: Central Plateau Vadose Zone Models, describes the approach, assumptions, process of determining the number of models required and domain of each model, input data, and processing common to all the models.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of the Excreta Bioassay Quality Control Program For April 1, 2006 Through March 31, 2007

A total of 66 urine samples, 6 blank fecal and 6 spiked artificial fecal samples were submitted during the report period (April 1, 2006 through March 31, 2007) to General Engineering Laboratories, South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for tritium, Sr, 238Pu, 239Pu, 241Am, 243Am 235U, 238U, elemental uranium and fecal analyses for 241Am, 238Pu and 239Pu were tested this year. The number of QC urine samples submitted during the report period represented 1.7% of the total samples submitted. In addition to the samples provided by IDP, GEL was also required to conduct their own QC program, and submit the results of analyses to IDP. About 36% of the analyses processed by GEL during the second year of this contract were quality control samples. GEL tested the performance of 16 radioisotopes, all of which met or exceeded the specifications in the Statement of Work. IDP concluded that GEL was performing well for all analyses tested, and concerns identified earlier were satisfactorily resolved.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Design and Modeling of Vacuum Pumping for Steady-State Pellet Fueling Systems

We report that future long-pulse magnetic confinement fusion reactors will require density and isotopic mixture control using steady-state repeating pellet injectors. For high-energy density burning plasmas, pellet velocities of 1 km/s and above will be required for sufficient plasma penetration to achieve high fueling efficiency. Currently, steady-state repeating injection systems utilize cryogenic extruder systems to produce an extrusion of solid deuterium or deuterium-tritium. In repeating light gas gun injectors, the solid extrusion is cut and simultaneously loaded into a barrel. Once loaded, a fast operating gas valve delivers a high pressure burst of gas to accelerate the pellet down the barrel and into the machine. This process takes ~10 ms to achieve. Adequate gas pumping of the extruder exhaust and injection line propellant gas collection chambers is necessary for optimal operation of the pellet fueling system. Excess solid from the extruder sublimates in an exhaust chamber. The gas pressure in the extruder exhaust chamber must remain low to maintain low heating loads on the cooling mechanism (cryorefrigerators or liquid helium flow) and to reduce thermal conduction to the extrusion. Pumping the injection line chambers is necessary to limit propellant gas flow into the machine. A numerical simulation code was created to predict temporal pumping performance for these repeating pellet injection systems. Lastly, this paper outlines the methods and assumptions used to create this model and compares results to the pellet injection system currently employed on DIII-D, the steady-state pellet injection system planned for the Wendelstein 7-X, and a brief analysis of the ITER conceptual pellet fueling system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of FTWC Vent System

A monitored exhaust system has been designed for use in venting the Flanged Tritium Waste Containers (FTWCs) at LANL. This system will provide controlled exhaust and emissions monitoring for the FTWCs, and also provide general area exhaust around the venting operations to measure any emissions which may bypass the primary vent system. A full description of the process and need for the system is described in the Pre-Construction Application for this project. This document describes the commissioning testing performed on the FTWC vent system to prepare it for use. The system has been tested and shown to meet ANSI standard requirements and is fully suitable for use.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Protocol for Determining Actual Flow Rate in FTWC Duct Systems

This paper is intended to document the theory and methods to determine the actual flow rate in the exhaust system used to ventilate the Flanged Tritium Waste Containers based on realtime instrument readings. Section 1 provides introductory and background material; Section 2 details the various correction factors used to adjust flow readings for ambient air pressure and temperature and other operational parameters. Section 3 provides guidance on implementing this process during venting operations, and Section 4 provides supporting documentation and also a field checklist that can be used by personnel during venting. For Revision 1, a summary of editorial changes made to the paper was added as Section 4.4, as well as a section documenting peer review (Section 4.5).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Waste Area Group 10, Operable Unit 10-08, Annual Monitoring Status Report for Fiscal Year 2009

This report documents the status of Fiscal Year 2009 groundwater monitoring performed in Waste Area Group 10 at the U.S. Department of Energy Idaho National Laboratory Site, as identified in the Groundwater Monitoring and Field Sampling Plan for Operable Unit 10-08. Twelve of the fourteen required wells were sampled, and all ten required intervals from the Westbay wells were sampled. Two wells were not sampled because they were in the process of being converted into multiple-sample-interval Westbay wells by the U.S. Geological Survey. Groundwater samples were analyzed for volatile organic compounds identified on the Contract Laboratory Program target analyte list as well as metals (filtered), anions, and radionuclides (i.e., I-129, tritium, Tc-99, gross alpha, gross beta, and Sr-90). No contaminant exceeded maximum contaminant levels in wells along the southern boundary of the Idaho National Laboratory Site or in guard wells. Iron was above its secondary maximum contaminant level of 300 ug/L in one well. The cause of the elevated iron concentration is uncertain. Lead was detected just below its action level. However, the zinc concentration was also elevated in these wells, and the source of the lead is probably galvanized riser pipe in the wells. Once the galvanized pipe is replaced, both lead and zinc concentrations should decline, as has been observed at other Waste Area Group 10 wells.

54 ENVIRONMENTAL SCIENCES↗

High efficiency GaP power conversion for Betavoltaic applications

AstroPower is developing a gallium phosphide (GaP) based energy converter optimized for radio luminescent light-based power supplies. A 'two-step' or 'indirect' process is used where a phosphor is excited by radioactive decay products to produce light that is then converted to electricity by a photovoltaic energy converter. This indirect conversion of beta-radiation to electrical energy can be realized by applying recent developments in tritium based radio luminescent (RL) light sources in combination with the high conversion efficiencies that can be achieved under low illumination with low leakage, gallium phosphide based devices. This tritium to light approach is inherently safer than battery designs that incorporate high activity radionuclides because the beta particles emitted by tritium are of low average energy and are easily stopped by a thin layer of glass. GaP layers were grown by liquid phase epitaxy and p/n junction devices were fabricated and characterized for low light intensity power conversion. AstroPower has demonstrated the feasibility of the GaP based energy converter with the following key results: 23.54 percent conversion efficiency under 968 muW/sq cm 440 nm blue light, 14.59 percent conversion efficiency for 2.85 muW/sq cm 440 nm blue light, and fabrication of working 5 V array. We have also determined that at least 20 muW/sq cm optical power is available for betavoltaic power systems. Successful developments of this device is an enabling technology for low volume, safe, high voltage, milliwatt power supplies with service lifetimes in excess of 12 years.

Sims, Paul E.↗

Results Of The Excreta Bioassay Quality Control Program For April 1, 2007 Through March 31, 2008

A total of 79 urine samples, 3 blank fecal and 5 spiked artificial fecal samples were submitted during the report period (April 1, 2007 through March 31, 2008) to General Engineering Laboratories, South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for tritium, Sr, 238Pu, 239Pu, 241Am, 243Am 235U, 238U, elemental uranium and fecal analyses for 241Am, 238Pu and 239Pu were tested this year. The number of QC urine samples submitted during the report period represented 1.8% of the total samples submitted. In addition to the samples provided by IDP, GEL was also required to conduct their own QC program, and submit the results of analyses to IDP. About 35% of the analyses processed by GEL during the third year of this contract were quality control samples. GEL tested the performance of 24 radioisotopes, all of which met or exceeded the specifications in the Statement of Work within statistical uncertainty (Table 4). IDP concluded that GEL was performing well for all analyses tested, and concerns identified earlier were satisfactorily resolved.

61 RADIATION PROTECTION AND DOSIMETRY↗

Bronze Alloy Development for Zinc Vapor Capture

After gamma-emitting 65 Zinc was detected in a vacuum pumping system contained in a tritium glovebox, a series of experiments were undertaken to develop a method and material to trap zinc vapors in an area that is more suitable for preventing dose to workers. In this study, bronze alloys with 0–30% tin were prepared using a powder metallurgical process and exposed to three levels of zinc vapors. Furthermore, all of the alloys demonstrated acceptable zinc gettering capacity; however, low tin content bronzes are considered for further testing.

36 MATERIALS SCIENCE↗

Tritium Aging of Regenerated LANA.75

Tritium Aging of Regenerated LANA.75 is a multi-year project. Activities include: tritium aging of a LANA.75 sample regenerated in 2018, regenerating a second tritium-aged LANA.75 sample, and verifying the thermal stability of LANA.75 under regeneration conditions. During FY19, the Task Technical Plan (TTP) addendum providing testing guidance for monitoring tritium aging of the regenerated LANA.75 sample was approved. A desorption isotherm at 150 °C was collected on the regenerated LANA.75 sample. A second desorption isotherm at 150 °C is scheduled to be collected along with additional desorption isotherms at 80 and 120 °C. Fabrication, pressure testing, and leak testing of the high temperature test cell for regeneration of the second tritium-aged LANA.75 sample was completed. Selection of the second LANA.75 sample to be regenerated is anticipated in FY20. Thermal stability testing of LANA.75 material was completed. Hydrogen desorption isotherms at 80, 100 and 120 °C were collected prior to and after a lengthy annealing process (200 hours combined over two weeks) at 750 °C. The isotherms showed similar performances for all temperatures. However, the plateau region for the isotherms after the annealing process were flatter, suggesting that the annealing process was beneficial to the hydride. Sample analyses, including XRD, SEM, ICP and particle size distribution, are ongoing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of space-charge effects in gaseous tritium as a source of distortions of the beta spectrum observed in the Troitsk neutrino-mass experiment

Results of searches for effects of space-charge accumulation in the gaseous tritium source in the Troitsk neutrino-mass experiment are presented. The broadening and the shift of the L3 line of conversion electrons in a {sup 83m}Kr gaseous source circulating together with tritium was investigated. The attained limit on the magnitude of fluctuations of the space-charge potential makes it possible to set a limit on the negative neutrino mass squared in the Troitsk neutrino-mass experiment (-0.8 < {delta}m{sub {nu}}{sup 2} {<=} 0 eV{sup 2}), a spurious effect associated with this potential. A statistically reliable shift of the position of the L3 line is discovered. This indicates that processes of of space-charge accumulation do indeed proceed in the source at a level that is significant for the future experiment Katrin.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low Level Radioactive Wastes Conditioning during Decommissioning of Salaspils Research Reactor

The decommissioning of Salaspils research reactor is connected with the treatment of 2200 tons different materials. The largest part of all materials ({approx}60 % of all dismantled materials) is connected with low level radioactive wastes conditioning activities. Dismantled radioactive materials were cemented in concrete containers using water-cement mortar. According to elaborated technology, the tritiated water (150 tons of liquid wastes from special canalization tanks) was used for preparation of water-cement mortar. Such approach excludes the emissions of tritiated water into environment and increases the efficiency of radioactive wastes management system for decommissioning of Salaspils research reactor. The Environmental Impact Assessment studies for Salaspils research reactor decommissioning (2004) and for upgrade of repository 'Radons' for decommissioning purposes (2005) induced the investigations of radionuclides release parameters from cemented radioactive waste packages. These data were necessary for implementation of quality assurance demands during conditioning of radioactive wastes and for safety assessment modeling for institutional control period during 300 years. Experimental studies indicated, that during solidification of water- cement samples proceeds the increase of temperature up to 81 deg. C. It is unpleasant phenomena since it can result in damage of concrete container due to expansion differences for mortar and concrete walls. Another unpleasant factor is connected with the formation of bubbles and cavities in the mortar structure which can reduce the mechanical stability of samples and increase the release of radionuclides from solidified cement matrix. The several additives, fly ash and PENETRON were used for decrease of solidification temperature. It was found, that addition of fly ash to the cement-water mortar can reduce the solidification temperature up to 62 deg. C. Addition of PENETRON results in increasing of solidification temperature up to 83 deg. C. Experimental data shows, that water/cement ratio significantly influences on water-cement mortar's viscosity and solidified samples mechanical stability. Increasing of water ratio from 0.45 up to 0.65 decreases water-cement mortar's viscosity from 1100 mPas up to 90 mPas. Significant reduction of viscosity is an important factor, which facilitates the fulfillment all gaps and cavities with the mortar during conditioning of solid radioactive wastes in containers. On the other hand, increase water ratio from 0.45 up to 0.65 decreases mechanical stability of water-cement samples from 23 N/mm{sup 2} to the 12 N/mm{sup 2}. It means that water-cement bulk stability significantly decreases with increasing of water content. Technologically is important to increase the tritiated water content in container with cemented radioactive wastes. It gives a possibility to increase the fulfillment of container with radioactive materials. On the other hand, additional water significantly reduces bulk stability of containers with cemented radioactive wastes, which can result in disintegration of radioactive wastes packages in repository during 300 years. Taking into account the experimental results, it is not recommended to exceed the water/cement ratio more than 0.60. Tritium and Cs{sup 137} leakage tests show, that radionuclides release curves has a complicate structure. Experimental results indicated that addition of fly ash result in facilitation of tritium and cesium release in water phase. This is unpleasant factor, which significantly decreases the safety of disposed radioactive wastes. Despite the positive impact on solidification temperature drop, the addition of fly ash to the cement-water mortar is not recommended in case of cementation of radionuclides in concrete containers. In conclusion: The cementation processes of solid radioactive wastes in concrete containers were investigated. The influence of additives on cementation processes was studied. It was shown, that the increasing of water ratio from 0.45 up to 0.65 decreases water-cement mortar's viscosity more than 10 times. Mechanical stability of samples decreases 2 times, which reduces the bulk stability of cemented radioactive wastes package. It is not recommended to increase water ratio more than 0.60 in cement-water mortar. Addition of flay ash to the water-cement mortar decreases the solidification temperature from 83 deg. C to 62 deg. C. However, it was found, that the addition of fly ash to the water-cement mortar facilitate the radionuclides leakage from solidified water-cement matrix. Therefore fly ash is not recommended for radioactive wastes cementation. It was shown that tritiated water can be used for cementation of solid radioactive wastes in concrete containers.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A distillation column for hydrogen isotope removal from liquid lithium

Recovery of tritium from plasma-facing components in fusion devices will be vital to future full-scale operation. Liquid, low-Z materials have demonstrated many inherent advantages over solid first wall materials. To this end, a thermal treatment method in the form of a distillation column for extraction of hydrogen isotopes from liquid lithium has been designed, developed, and constructed at the Center for Plasma-Material Interactions at the University of Illinois at Urbana-Champaign. Use of induction heating and lithium condensation stages are the two qualities that set this design apart from other thermal treatment systems. Induction heating capabilities were modeled using the COMSOL Multiphysics software, which were validated when commissioning the physical heater module. Proof-of-concept tests were performed in the prototype column, which were undertaken as batch processes to investigate the efficacy with which the column could remove hydrogen gas from lithium-rich and lithium hydride-rich samples. All of the tests reported used lithium hydride as a surrogate for lithium deuteride and lithium tritide. The design process and results from the initial tests will be discussed, along with the envisioned placement of this treatment scheme in a fully-functional lithium loop.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preheating temperature effect on tritium retention in VPS-W

The W coating by Vacuum Plasma Spraying (VPS) technology is thought to be reasonable for most plasma facing components in future fusion reactors. In this paper the deuterium retention behavior for the Vacuum Plasma Spraying (VPS) tungsten (W) coating has been studied to demonstrate the tritium retention as a function of heating temperature. It has been found that two major deuterium desorption stages were observed at the temperature regions of 400 - 700 K (Stage 1) and 900 - 1100 K (Stage 2), considering that Stage 1 has been linked to the desorption of deuterium trapped by near surface and intrinsic defects, and Stage 2 has been related to the desorption of deuterium bound to impurities as C-D bonds. By heating the sample above 673 K, the major peak of C-1s shifted from C-O bond to C-C bond, where the retention of deuterium as Stage 2 has increased. Therefore it indicates that the hydrogen isotope retention was controlled by the amount of C-C bond in VPS, most of which was contaminated during the VPS coating process. The comparison of several samples (VPS-W with shading, VPS-W without shading and Polycrystalline W (PCW)) shows that the carbon impurity has a large affinity with deuterium and makes stable trapping states compared to that with intrinsic defects and grain boundaries. However, most of them was reduced by heating at 1173 K. Therefore, heating treatment is quite important to get rid of carbon impurities and refrain higher tritium retention in VPS. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of fusion reaction history in inertially confined burning plasmas

Direct evidence of inertially confined fusion ignition appears in the abrupt temperature increase and consequent rapid increase in the thermonuclear burn rate as seen in the reaction history. The Gamma Reaction History (GRH) and Gas Cherenkov Detector (GCD) diagnostics are γ-based Cherenkov detectors that provide high quality measurements of deuterium–tritium fusion γ ray production and are, thus, capable of monitoring the thermonuclear burn rate. Temporal shifts in both peak burn time and burn width have been observed during recent high-yield shots (yields greater than 1017 neutrons) and are essential diagnostic signatures of the ignition process. While the current GRH and GCD detectors are fast enough to sense the changes of reaction history due to alpha heating, they do not have enough dynamic range to capture the onset of alpha heating. The next generation of instrumentation, GRH-15m, is proposed to increase the yield-rate coverage to measure the onset of alpha-heating.

42 ENGINEERING↗

Constraining Bedrock Groundwater Residence Times in a Mountain System with Environmental Tracer Observations and Bayesian Uncertainty Quantification: Modeling and Data Package

Groundwater residence times provide fundamental descriptions of hydrologic dynamics and mixing processes in mountainous watersheds. Yet, few observational datasets that can constrain groundwater residence times over broad timescales are available in high elevation mountain systems. Here we present field observations from May 2021 of dissolved noble gases (He, Ne, Ar, Kr, and Xe), Chloroflourcarbons (CFCs), Sulfurhexaflouride (SF6), and tritium (3H) sampled from the Pumphouse Lower Montane study site (wells PLM1, PLM6, and PLM7) within the East River Watershed, Colorado. The presented noble gas (PLM_noblegas_2021.csv) and environmental tracer (PLM_tracers_2021.csv) observation datasets, along with the associated modeling scripts, aide in quantifying groundwater residence times and recharge conditions in a high elevation mountain system. Furthermore, the modeling scripts quantify groundwater residence time and noble gas recharge condition uncertainties using a novel Markov-chain Monte Carlo approach. All data modeling scripts are written in the Python code.

54 ENVIRONMENTAL SCIENCES↗

Audit Report The Procurement of Safety Class/Safety-Significant Items at the Savannah River Site

The Department of Energy operates several nuclear facilities at its Savannah River Site, and several additional facilities are under construction. This includes the National Nuclear Security Administration's Tritium Extraction Facility (TEF) which is designated to help maintain the reliability of the U.S. nuclear stockpile. The Mixed Oxide Fuel Fabrication Facility (MOX Facility) is being constructed to manufacture commercial nuclear reactor fuel assemblies from weapon-grade plutonium oxide and depleted uranium. The Interim Salt Processing (ISP) project, managed by the Office of Environmental Management, will treat radioactive waste. The Department has committed to procuring products and services for nuclear-related activities that meet or exceed recognized quality assurance standards. Such standards help to ensure the safety and performance of these facilities. To that end, it issued Departmental Order 414.1C, Quality Assurance (QA Order). The QA Order requires the application of Quality Assurance Requirements for Nuclear Facility Applications (NQA-1) for nuclear-related activities. The NQA-1 standard provides requirements and guidelines for the establishment and execution of quality assurance programs during the siting, design, construction, operation, and decommissioning of nuclear facilities. These requirements, promulgated by the American Society of Mechanical Engineers, must be applied to 'safety-class' and 'safety-significant' structures, systems and components (SSCs). Safety-class SSCs are defined as those necessary to prevent exposure off site and to protect the public. Safety-significant SSCs are those whose failure could irreversibly impact worker safety such as a fatality, serious injury, or significant radiological or chemical exposure. Due to the importance of protecting the public, workers, and environment, we initiated an audit to determine whether the Department of Energy procured safety-class and safety-significant SSCs that met NQA-1 standards at the Savannah River Site. Our review disclosed that the Department had procured and installed safety-class and safety-significant SSCs that did not meet NQA-1 quality standards. Specifically, we identified multiple instances in which critical components did not meet required quality and safety standards. For example: (1) Three structural components were procured and installed by the prime contractor at Savannah River during construction of the MOX Facility that did not meet the technical specifications for items relied on for safety. These substandard items necessitated costly and time consuming remedial action to, among other things, ensure that nonconforming materials and equipment would function within safety margins; (2) In six instances, items used in the construction of TEF failed to satisfy quality standards. In one of these situations, operating procedures had to be modified to ensure that the problem item did not compromise safety; and (3) Finally, at the ISP, one component that did not meet quality standards was procured. The failure of the item could have resulted in a spill of up to 15,000 gallons of high-level radioactive waste. Based on an extensive examination of relevant internal controls and procurement practices, we concluded that these failures were attributable to inadequate attention to quality assurance at Savannah River. Simply put, Departmental controls were not adequate to prevent and/or detect quality assurance problems. For example, Federal and prime contractor officials did not expressly require that subcontractors or lower-tiered vendors comply with quality assurance requirements. Additionally, management did not effectively communicate quality assurance concerns between the several Departmental program elements operating at Savannah River. The procurement and installation of these nonconforming components resulted in cost increases. For example, as of October 2008, the MOX Facility had incurred costs of more than $680,000 due to problems associated with the procurement of $11 million of nonconforming safety-class reinforcing steel. In general, the internal control weaknesses we discovered could have permitted, without detection, the procurement and installation of safety critical components that did not meet quality assurance standards. In a worst case scenario, undetected, nonconforming components could fail and injure workers or the public. In certain instances, the Department took steps to ensure that the prime contractors at Savannah River began action to remediate nonconforming components and to strengthen policies and procedures. Additionally, the Department took actions to ensure that critical components necessary for projects worked as designed by requiring that the prime contractor place personnel at manufacturers' locations. Further, the Department had suspended work with certain other manufacturers due to quality assurance problems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reactive transport modeling for supporting climate resilience at groundwater contamination sites

Abstract. Climate resilience is an emerging issue at contaminated sites and hazardous waste sites, since projected climate shifts (e.g., increased/decreased precipitation) and extreme events (e.g., flooding, drought) could affect ongoing remediation or closure strategies. In this study, we develop a reactive transport model (Amanzi) for radionuclides (uranium, tritium, and others) and evaluate how different scenarios under climate change will influence the contaminant plume conditions and groundwater well concentrations. We demonstrate our approach using a two-dimensional (2D) reactive transport model for the Savannah River Site F-Area, including mineral reaction and sorption processes. Different recharge scenarios are considered by perturbing the infiltration rate from the base case as well as considering cap-failure and climate projection scenarios. We also evaluate the uranium and nitrate concentration ratios between scenarios and the base case to isolate the sorption effects with changing recharge rates. The modeling results indicate that the competing effects of dilution and remobilization significantly influence pH, thus changing the sorption of uranium. At the maximum concentration on the breakthrough curve, higher aqueous uranium concentration implies that sorption is reduced with lower pH due to remobilization. To better evaluate the climate change impacts in the future, we develop the workflow to include the downscaled CMIP5 (Coupled Model Intercomparison Project) climate projection data in the reactive transport model and evaluate how residual contamination evolves through 2100 under four climate Representative Concentration Pathway (RCP) scenarios. The integration of climate modeling data and hydrogeochemistry models enables us to quantify the climate change impacts, assess which impacts need to be planned for, and therefore assist climate resiliency efforts and help guide site management.

54 ENVIRONMENTAL SCIENCES↗