Search NASA⌕ Search

SEARCH · Search NASA

Results for “water temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

AWAKEN 2023 CLAMPS2 MWR TROPoe Retrievals

These files contain 24 hour periods of retrieved thermodynamic profiles derived from observations collected by the CLAMPS2 Microwave Radiometer (MWR). The TROPoe algorithm is a python equivalent to the AERIoe algorithm (see Turner and Loehnert, 2014; Turner and Blumberg 2019). These data were collected during the AWAKEN project. MWR only data is available.

54 ENVIRONMENTAL SCIENCES↗

AWAKEN 2023 CLAMPS1 AERI TROPoe Retrievals

These files contain 24 hour periods of retrieved thermodynamic profiles derived from observations collected by the CLAMPS1 Atmospheric Emitted Radiance Interferometer (AERI). The TROPoe algorithm is a python equivalent to the AERIoe algorithm (see Turner and Loehnert 2014; Turner and Blumberg 2019). These data were collected during the AWAKEN project. AERI only data is available.

54 ENVIRONMENTAL SCIENCES↗

The ARENA Test Bed – A Versatile Resource for I&C Development and Validation

The Accelerated and Real-time Experimental Nodal Assessment (ARENA) Test Bed at the Pacific Northwest National Laboratory (PNNL) is a versatile resource for development and validation of instrumentation and control (I&C) technologies. This capability was created to facilitate in-situ testing of nuclear electrical cables in various simulated operational environments. Using cable trays, a control box, and selected test components, low voltage cables can be staged to experience local adverse environments such as elevated temperature and water immersion. Cable condition can be continuously monitored over time to track the effect of local stresses using nondestructive assessment tools. A heads-up display (ARENA TV) plots key data in real-time for users. The ARENA Test Bed has recently been used to evaluate the potential for spread spectrum time domain reflectometry (SSTDR) to monitor thermal aging of a portion of live cable powering a three-phase motor. The arrangement provided the opportunity to directly compare the performance of the novel online SSTDR method with offline results from the more standard frequency domain reflectometry (FDR) method. The ability of SSTDR and FDR to identify the presence of water in immersed shielded and unshielded cables and to detect ground faults was also assessed. A digital twin is being developed to track and predict FDR signals from a thermally aging conceptual cable region to compare with measured signals from the ARENA physical counterpart. The test bed concept addresses an important need in nuclear I&C monitoring tool development. New tools and techniques can be developed in the test bed and validated versus known methods and physical measurements. Digital twins and machine learning engines can be populated with measured data in a controlled environment that would not be readily available in the actual nuclear power plant. Proposed monitoring strategies can be confirmed for effectiveness through objective evaluation. It is anticipated that the PNNL ARENA Test Bed will be a valuable resource in advancing nuclear plant instrumentation.

nuclear electrical cables, ARENA Test Bed, conditi↗

Thermal Extraction and Delivery from Advanced Reactor Systems

This document presents preliminary thermodynamic analysis of thermal extraction and delivery from advanced nuclear reactors. Light-water, high temperature gas, sodium fast, and molten salt reactors are templated and analyzed for thermal extraction from nominal steam production conditions. Uncontrolled, controlled, and partial admission steam extraction methods are described and analyzed to show the differences in system impact from the various methods. Thermal delivery modeling results show comparisons that have become possible through the computational capabilities of the thermal delivery model. Due to the significant degrees of freedom of the problem, specific cases are used to compare the thermodynamic costs of heat transport using various heat transfer fluids. All this work is done using Modelica models, allowing for the future application of models in dynamic analyses beyond the steady-state calculations presented in this report. Appendices describe additional capabilities and methods that can help users analyze complex problems using HYBRID models developed in Modelica.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Energy Systems Integration Facility (ESIF): World-Class Systems Integration Capabilities and Research

The Energy Systems Integration Facility (ESIF), located at the National Renewable Energy Laboratory (NREL) South Table Mountain campus, is a world-renowned user facility for research and development of modern, advanced, and clean energy technologies. ESIF is distinguished by its continuously evolving, highly integrated systems that span throughout the building, connecting research capabilities across multiple laboratories and test areas. The primary ESIF research systems include: [1] data, cyber, and control networks, [2] research electrical distribution buses (REDB), [3] thermal integration infrastructure, and [4] hydrogen systems. The data, cyber, and control networks provide monitoring, control, communication, automation, visualization, and time series data storage and tagging capabilities for research projects and ESIF systems, including facility safety functions. The REDB system consists of four dedicated AC and DC electrical power networks that can connect devices located across the facility through versatile, automatic circuit configuration to support complex power electronics experiments up to the megawatt-scale. The thermal integration infrastructure consists of three temperature-conditioned water loops that provide heating and cooling interfaces and capabilities for thermal energy research. The hydrogen systems provide megawatt-scale hydrogen production, drying, compression, high-pressure storage, and delivery to laboratory end uses, including hydrogen fuel cell vehicle fueling. The ESIF research systems interconnect and extend throughout the various lab areas of the facility to create elaborate networks composed of diverse technologies for cutting-edge research. The ESIF capabilities are operated and stewarded by the ESIF Research Operations group, who also actively upgrade and advance the systems to ensure they remain ahead of anticipated research - enabling the success of many pioneering energy integration projects. The poster, created by members of the ESIF Research Operations team, highlights and summarizes the four core integrated systems at ESIF. The poster was first presented at the internal NREL Energize Forum on May 13th, 2024, and received the "Best Poster" award.

capabilities↗

Anticipating water distribution service outages from increasing temperatures

With projected temperature increases and extreme events due to climate change for many regions of the world, characterizing the impacts of these emerging hazards on water distribution systems is necessary to identify and prioritize adaptation strategies for ensuring reliability. To aid decision-making, new insights are needed into how water distribution system reliability to climate-driven heat will change, and the proactive maintenance strategies available to combat failures. To this end, we present the model Perses, a framework that joins a water distribution network hydraulic solver with reliability models of physical assets or components to estimate temperature increase-driven failures and resulting service outages in the long term. A theoretical case study is developed using Phoenix, Arizona temperature profiles, a city with extreme temperatures and a rapidly expanding infrastructure. By end-of-century under hotter futures there are projected to be 1%–5% more pump failures, 2%–5% more PVC pipe failures, and 3%–7% more iron pipe failures (RCP 4.5–8.5) than a baseline historical temperature profile. Service outages, which constitute inadequate pressure for domestic and commercial use are projected to increase by 16%–26% above the baseline under maximum temperature conditions. The exceedance of baseline failures, when compounded across a large metro region, reveals potential challenges for budgeting, management, and maintenance. An exploration of the mitigation potential of adaptation strategies shows that expedited repair times are capable of offsetting the additional outages from climate change, but will come with a cost.

54 ENVIRONMENTAL SCIENCES↗

Water vapor oxidation behaviors of nuclear graphite IG-110 for a postulated accident scenario in high temperature gas-cooled reactors

Water leakage in accidental conditions of high temperature gas-cooled reactors is one of the most critical problems that can compromise the integrity of different nuclear components. In this study, oxidation behaviors of nuclear graphite IG-110 in water ingress accidental conditions were investigated. Mass loss and oxidation rates were evaluated after oxidation tests at temperatures up to 1400 °C in an Ar-20 vol% H 2 O mixed atmosphere. The activation energy decreased from 318.6 to 148.9 kJ/mol with temperature, indicating two different oxidation regimes. The cross-sections of the oxidized samples were systematically characterized. The corresponding logarithmic porosity profiles showed a temperature dependency. Pore formation moved toward near-surface regions with increasing temperature and preferential binder oxidation, with filler particle degradation. Furthermore, oxidant concentration profiles and oxidation depths were estimated using a theoretical model and compared with the experimental results. This work provides important benchmark data and safety analysis guidance for the accident scenario in high temperature gas-cooled reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Continuous sensor suite measurements of weather, energy, soil and flux at four PumpHouse sites at the East River, Colorado

The purpose of this package is to monitor energy and water fluxes using a comprehensive set of sensors integrated on a tripod set up at 4 locations at the East River watershed in Colorado in the Upper Colorado River Basin as part of the Scientific Focus Area (SFA) research led by the Lawrence Berkeley National Lab (LBNL). This is a continuous sensor suite measurements of weather, energy, soil and flux at four East River pumphouse sites (ER-PHS1, ER-PHS2, ER-PHS3 and ER-PHS4) include: (1) soil CO2 concentration, CO2 flux and heat flux from soil surface; (2) photosynthetic active radiation flux at 1 m; (3) incoming/outcoming short and long wave radiation at 1 m, and user calculated net short and long wave radiation; (4) oxygen concentration and surface infrared temperature; (5) soil volumetric water content, temperature, and electrical conductivity at 10, 30, 60, 115 cm depth 115 cm depth; (6) soil matric potential and temperature at 30 cm depth; (7) incoming short wave radiation at 3 m height; (8) rainfall precipitation; (9) lightning strikes and strike distances; (10) wind direction and speed, maximum wind gust at 3 m; (11) air temperature, vapor pressure and barometric pressure at 3 m; (12) X _axis_level and Y_axis_level_(degree), tilt of the ATMOS 41 sensor; (13) maximum rainfall rate; (14) relative humidity sensor temperature at 3 m; (15) internally calculated vapor pressure deficit at 3 m with vapor pressure, relative humidity and sensor temperature measurements; (16) user calculated vapor pressure.These datasets contain data from Oct 11 2019 to March 20, 2020, and new datasets will be updated on annual basis. Files uploaded in Excel and Word, with copies in csv and pdf format.

54 ENVIRONMENTAL SCIENCES↗

Supersaturation Variability from Scalar Mixing: Evaluation of a New Subgrid-Scale Model Using Direct Numerical Simulations of Turbulent Rayleigh–Bénard Convection

We report that supersaturation fluctuations in the atmosphere are critical for cloud processes. A nonlinear dependence on two scalars - water vapor and temperature - leads to different behavior than single scalars in turbulent convection. For modeling such multiscalar processes at subgrid scales (SGS) in large-eddy simulations (LES) or convection-permitting models, a new SGS scheme is implemented in CM1 that solves equations for SGS water vapor and temperature fluctuations and their covariance. The SGS model is evaluated using benchmark direct-numerical simulations (DNS) of turbulent Rayleigh–Bénard convection with water vapor as in the Michigan Tech Pi Cloud Chamber. This idealized setup allows thorough evaluation of the SGS model without complications from other atmospheric processes. DNS results compare favorably with measurements from the chamber. Results from LES using the new SGS model compare well with DNS, including profiles of water vapor and temperature variances, their covariance, and supersaturation variance. SGS supersaturation fluctuations scale appropriately with changes to the LES grid spacing, with the magnitude of SGS fluctuations decreasing relative to those at the resolved scale as the grid spacing is decreased. Sensitivities of covariance and supersaturation statistics to changes in water vapor flux relative to thermal flux are also investigated by modifying the sidewall conditions. Relative changes in water vapor flux substantially decrease the covariance and increase supersaturation fluctuations even away from boundaries.

54 ENVIRONMENTAL SCIENCES↗

Combined Mesonet and Tracker

Title: Combined Mesonet and Trackers (UNL Mobile Mesonets) Authors University of Nebraska PI: Adam Houston, UNL Professor (ahouston2@unl.edu) Mailing Address: 126 Bessey Hall P.O. Box 880340 Lincoln, NE 68588-0340 CoMeT Overview The University of Nebraska-Lincoln operates three Combined Mesonet and Tracker (CoMeTs). CoMeTs are Ford Explorers (model years 2015, 2017, and 2019) with forward-mounted suites of meteorological sensors and dual moonroofs, combining the capability of a mobile mesonet to collect near-surface observations with the capability of an unmanned aircraft systems (UAS) tracker vehicle, which enables an observer in the second row of seats to see the aircraft and maintain compliance with Federal Aviation Administration policies on UAS operation. The CoMeTs collect observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155A, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, and vehicle heading using a KVH Industries C-100 fluxgate compass (Barbieri et al. 2019). The HMP155A and 109SS-L thermistor are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). This list of sensors is also included in the CoMeT data file metadata. Manufacturer specifications for these instruments are given in Table 1 of Hanft and Houston (2018). The reported measured quantities are summarized below.CoMeT-3 was funded through an equipment allocation included in the NSF TORUS award (AGS-1824649). Instrument Description The specific sensors included on each CoMeT are summarized in the table at the end of this section. In general each CoMeT collects observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210 barometer with a Gill pressure port, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, position using a Garmin 19x HVS receiver, and vehicle heading using a KVH Industries C-100 fluxgate compass. The HMP155 and 109SS are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). Fast temperature and corrected RH measurements (using sensors housed within the U-tube) have a time constant of 10-12 s based on data collected across a temperature and RH shock during the CLOUD-MAP 2017 calibration/validation tests on June 26, 2017. Vehicle speed was < 10 kts for this test. CoMeT-1 CoMeT-2 CoMeT-3 Slow Temperature Slow RH Vaisala HMP155A-L20-PT Part #: 22280-7 Vaisala HMP155E Part #: E1AA11A0B1A1A0A Vaisala HMP155E Part #: E1AA11A0B1A1A0A Fast temperature Campbell Scientific 109SS-L20-PT Part #: 21448-3 Campbell Scientific 109SS-L12-PW Part #: 21448-109 Campbell Scientific 109SS-L12-PW Part #: 21448-150 Pressure Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Wind RM Young 05103-L20-PT Part #: 18435-310 RM Young 05103-L20-PW Part #: 18435-244 RM Young 05103-L20-PW Part #: 18435-244 GPS Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Compass KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 Logger Campbell Scientific CR6-NA-XT-SW Part #: 28385-9 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Data Collection and Real-Time Processing The reported measured quantities are summarized in the table below. Quantity Units Source Epoch time Seconds GPS Latitude and longitude Degrees GPS Altitude m GPS Pressure hPa PTB210 Temperature (fast) deg C 109SS-L Temperature (slow) deg C HMP155 RH (slow) % HMP155 Vehicle speed m/s GPS Vehicle heading deg C-100 and GPS In addition to the measured variables, several derived variables are calculated. Corrected/fast relative humidity (%) Relative humidity is adjusted to the fast temperature following Richardson et al. (1998) and Houston et al. (2016). Water vapor mixing ratio (g/kg) Dew point temperature (&deg;C) Potential temperature (Kelvin) Virtual potential temperature (Kelvin) Equivalent potential temperature (Kelvin) Regular intercomparisons between all three CoMeTs were performed during TORUS 2019. Comparisons were also conducted between CoMeT-1 and CoMeT-2 during LAPSE-RATE (2018) on 14 July. In these intercomparisons, the vehicles were parked adjacent to each other aligned perpendicular to (and facing into) the wind. To minimize engine heating effects, intercomparisons were only conducted when the wind speed was >10 kts. Data Format Original data files for each deployment are saved as text files and then converted to NetCDF. NetCDF versions have units that are CF compliant and may not match the original units in the txt files. The naming convention for the NetCDF files is as follows: UNL.CoMeT3.{deployment date YYYYMMDD}.{start time of observation collection in UTC HHMM}.L2.{post-processing codes}.cdf example: UNL.CoMeT3.20190627.1931.L2.g1.f1.cdf Post-processing codes are included to track modifications to the raw data. These codes are closely connected to error flags associated with each record. Each letter corresponds to a particular instrument: g: GPS p: Barometer tf: Fast temperature ts: Slow temperature rh: Relative humidity f: Compass w: Wind monitor a: All instruments Each number corresponds to a particular post-processing action described more below. Measured and derived variables are included in the following table. Variable Heading Standard Name Units time Time seconds since 00:00:00, 01-01-1970 Alt Altitude meters lat Latitude degrees north lon Longitude degrees east fast_temp Air Temperature kelvin slow_temp Air Temperature kelvin pressure Air Pressure pascals logger_RH Relative Humidity percent calc_corr_RH Relative Humidity percent wind_speed Wind Speed meters per second wind_dir Wind From Direction degrees vehicle_dir Vehicle Direction degrees dewpoint Dew Point Temperature kelvin mixing_ratio Humidity Mixing Ratio g/g theta Air Potential Temperature kelvin theta_v Virtual Potential Temperature kelvin theta_e Equivalent Potential Temperature Kelvin error_flag The error_flag variable is a string that matches the post-processing codes listed above. All instruments will have an associated code, but will have a &ldquo;0&rdquo; if the datum is unchanged from the initial processed value. Error Codes The following table summarizes the error codes for data collected before 2020: Error Code Relevant CoMeT Description g1 1,2,3 Exact correction. GPS position and time reprocessed from raw data g2 1 As far as we can tell this is an exact correction to an error in the GPS time. During the correct time periods the time suddenly went backwards ~250s and stayed at this offset for 750s when it corrected itself. The offset was applied to the &ldquo;time warp&rdquo; period. p1 2 Approximate correction. Hole in the pressure tube connecting the pressure port to the barometer. Resulted in erroneously low air pressure measurements when the vehicle was in motion. Derived variables recalculated (dew point temperature [e depends on qv and p], water vapor mixing ratio, potential temperature, virtual potential temperature, equivalent potential temperature) a1 3 Exact correction. Missing data reprocessed from raw data a2 1 Bug fix to bias correction for ts1, ts2, and rh1: water vapor mixing ratio was off by a factor of 10 and virtual potential temperature was wrong because of this. f1 3 No correction, missing data. Fluxgate compass inoperable. Wind speed and direction calculated using GPS-derived vehicle heading instead. rh1 1 Approximate correction. Constant bias of +1.7% removed from relative humidity. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts1 1 Approximate correction. Constant bias of +0.6 K removed from slow temperature. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts2 1 Approximate correction. Constant bias of +1.0 K removed. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) References Bolton, D., 1980: The Computation of Equivalent Potential Temperature. Mon. Wea. Rev., 108, 1046&ndash;1053, https://doi.org/10.1175/1520-0493(1980)108<1046:TCOEPT>2.0.CO;2. Hanft, W., and A. L. Houston, 2018: An Observational and Modeling Study of Mesoscale Air Masses with High Theta-E. Mon. Wea. Rev., 146, 2503&ndash;2524, https://doi.org/10.1175/MWR-D-17-0389.1.Wexler Houston, A. L., R. J. Laurence III, T. W. Nichols, S. Waugh, B. Argrow, and C. L. Ziegler, 2016: Intercomparison of unmanned aircraft-borne and mobile mesonet atmospheric sensors. Journal of Atmospheric and Oceanic Technology. 33, 1569-1582, doi: 10.1175/JTECH-D-15-0178.1. Lowe, P. R., 1977: An Approximating Polynomial for the Computation of Saturation Vapor Pressure. J. Applied Meteorology, 16, 100&ndash;103. Richardson, S. J., S. E. Frederickson, F. V. Brock, and J. A. Brotzge, 1998: Combination temperature and relative humidity probes: Avoiding large air temperature errors and associated relative humidity errors. Preprints, 10th Symp. On Meteorological Observations and Instrumentation, Phoenix, AZ, Amer. Meteor. Soc., 278&ndash;283. Waugh, S., and S. E. Frederickson, 2010: An improved aspirated temperature system for mobile meteorological observations, especially in severe weather. 25th Conf. on Severe Local Storms, Denver, CO, Amer. Meteor. Soc., P5.2. [Available online at https://ams.confex.com/ams/25SLS/techprogram/paper_176205.htm.]

54 ENVIRONMENTAL SCIENCES↗

Probabilistic Risk Assessment of a Light Water Reactor Coupled with a High Temperature Electrolysis Hydrogen Production Plant

Two generic probabilistic risk assessments (PRA) for the addition of a heat extraction system (HES) addition to a light water reactor (LWR) are performed, one for a pressurized water reactor (PWR) and one for a boiling water reactor (BWR). The results investigate the applicability of the potential licensing approaches which do not require a full U.S. Nuclear Regulatory Commission (NRC) licensing review. The PRAs are generic, and some assumptions are made. Many conservative assumptions from a the preliminary PWR PRA report were eliminated using design data for both the HES and the high temperature electrolysis facility (HTEF). The results of the PRA indicate that the 10 CFR 50.59 licensing approach is justified due to the minimal increase in initiating event frequencies for all DBAs, none exceeding 5.6%. The PRA results for CDF and LERF support the use of RG 1.174 as further risk information that supports a change without a full LAR. Further insights provided through hazard analysis and sensitivity studies confirm with high confidence that the safety case for licensing an HES addition and a HTEF sited at 1.0 km from the NPP is strong and that the placement of a HTEF at 0.5 km is a viable case. Site specific information can alter these conclusions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Incorporating two-dimensional conduction modeling techniques into an energy simulation program: The EnergyPlus radiant system example

Due to the inherent complexity of multi-dimensional solutions for transient conduction in a multilayered building element, most heat balance-based algorithms assume that conduction occurs only in one dimension—through the building element between the inside and outside environments. Usually, since the length and width of the elements are much greater than the thickness of the element, this is a valid assumption. However, there are some cases such as hydronic radiant slabs where this assumption may not lead to an accurate estimate of the energy consumption of the system. In a hydronic radiant slab, water tubes are embedded in a slab, and hot or chilled water is circulated to meet any heating or cooling loads. The energy consumption of such a system will depend highly on the temperature of the water being sent to the slab (i.e., produced by the boiler or chiller). The temperature of the water that must be sent to the slab will depend on the spacing of the tubes, the multilayer construction of the building element, and the boundary conditions to which the construction is exposed. Thus, to accurately predict the energy consumption of such a system, a transient two-dimensional heat conduction model must be integrated with a heat balance-based simulation. This paper demonstrates the potential loss of accuracy associated with the one-dimensional radiant system models by providing a comparison of one- and two-dimensional solutions using EnergyPlus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Water quality data collected from the Muskegon River (MI, USA) using AquaBOT June-July 2024.

This dataset contains processed output from AquaBOT, which combines 30-second interval measurements of GPS location and YSI water quality parameters (temperature (degrees Celsius), dissolved oxygen (mg/l), specific conductance(microSiemens/cm at 25 degrees Celsius), and turbidity (NTU)), for 3 sections of the Muskegon River in Michigan, USA. The file aquabot2024_MuskegonRiver.csv has information on locations, dates and times, and observations. The data were processed by removing observations recorded before and after AquaBOT was in the water and observations where no data values were recorded. No other QA/QC was done. This research was performed as part of the DOE Research Development and Partnership Pilot award “Expanding Collaborative Capacity to Address Climate Resiliency in the Great Lakes Region”, which aims to expand collaborations between researchers at Central Michigan University and U.S. Department of Energy labs and projects focused on enhancing climate resilience in Great Lakes communities and ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Moisture Absorbing and Water Self‐Releasing from Hybrid Hydrogel Desiccants

Abstract Atmospheric moisture is a valuable resource for fresh water and potentially sustainable energy. However, direct harvesting water from moisture (the vapor form) remains the most challenging. Hybrid desiccants made from hydrogels embedded with salt offer promise in absorbing moisture. However, the desorption process often requires additional energy to heat the samples. Here, poly(acrylic acid) (PAA) hydrogels embedded with lithium chloride are prepared, demonstratng simultaneous moisture absorption and self‐release of liquid water at room temperature with 50–90% relative humidity. The water self‐releasing process can be separated into two distinct stages: 1) surface release, where water droplets grow on the hydrogel surface due to differences in nucleation and diffusion rates, and 2) bulk release, triggered by the collapse of polymer chains, subsequently releasing water from the hydrogel network. Factors such as salt concentration, hydrogel crosslinking density, and film thickness are investigated to better understand the moisture absorption and water‐releasing processes. Moreover, hydrophobic domains are introduced onto the salt‐embedded PAA films, creating an edge effect that enhances the droplet growth rates. When the hydrophobic domains are patterned, the movement of released water can be guided, resulting in a threefold increase in water removal rate attributed to gravitational force.

Chemistry↗

Monitoring of Temperature Measurements for Different Flow Regimes in Water and Galinstan with Long Short-Term Memory Networks and Transfer Learning of Sensors

Temperature sensing is one of the most common measurements of a nuclear reactor monitoring system. The coolant fluid flow in a reactor core depends on the reactor power state. We investigated the monitoring and estimation of the thermocouple time series using machine learning for a range of flow regimes. Measurement data were obtained, in two separate experiments, in a flow loop filled with water and with liquid metal Galinstan. We developed long short-term memory (LSTM) recurrent neural networks (RNNs) for sensor predictions by training on the sensor’s own prior history, and transfer learning LSTM (TL-LSTM) by training on a correlated sensor’s prior history. Sensor cross-correlations were identified by calculating the Pearson correlation coefficient of the time series. The accuracy of LSTM and TL-LSTM predictions of temperature was studied as a function of Reynolds number (Re). The root-mean-square error (RMSE) for the test segment of time series of each sensor was shown to linearly increase with Re for both water and Galinstan fluids. Using linear correlations, we estimated the range of values of Re for which RMSE is smaller than the thermocouple measurement uncertainty. For both water and Galinstan fluids, we showed that both LSTM and TL-LSTM provide reliable estimations of temperature for typical flow regimes in a nuclear reactor. The LSTM runtime was shown to be substantially smaller than the data acquisition rate, which allows for performing estimation and validation of sensor measurements in real time.

Pantopoulou, Stella↗

Energy-Efficient and Water-Saving Sorbent Regeneration at Near Room Temperature for Direct Air Capture

Here this study reports energy-efficient and water-saving microwave-accelerated regeneration of sorbent (MARS) for dilute carbon capture from the ambient air. The experimental studies indicated that the CO 2 desorption rate from the chemisorbents increased with microwave output under near-isothermal conditions at near room temperature. The reduced activation energy of MARS, i.e., 20–28 kJ/mol, indicated enhanced CO 2 desorption kinetics by microwave-induced rotational–vibrational (rovibrational) coupling transitions, primarily due to the highly polarized feature of the carbamate (CO 2 -PEI). The instant and selective delivery of microwave energy to the targeted polarized C–N bonds at room temperature is particularly advantageous for energy-efficient direct air capture. The experimental results also demonstrated a good working capacity of 0.6–1.4 mmol of CO 2 /g and a promising rapid MARS-DAC process with microwave swing. As it does not require steam regeneration and heat exchanger, a simple MARS process is attractive for CO 2 capture in water-stressed regions.

36 MATERIALS SCIENCE↗