Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Technical Note: Unsupervised C-arm pose tracking with radiographic fiducial

Purpose: C-arm fluoroscopy reconstruction, such as that used in prostate brachytherapy, requires that the relative poses of the individual C-arm fluoroscopy images must be known prior to reconstruction. Radiographic fiducials can provide excellent C-arm pose tracking, but they need to be segmented in the image. The authors report an automated and unsupervised method that does not require prior segmentation of the fiducial. Methods: The authors compute the individual C-arm poses relative to a stationary radiographic fiducial of known geometry. The authors register a filtered 2D fluoroscopy image of the fiducial to its 3D model by using image intensity alone without prior segmentation. To enhance the C-arm images, the authors investigated a three-step cascade filter and a line enhancement filter. The authors tested the method on a composite fiducial containing beads, straight lines, and ellipses. Ground-truth C-arm pose was provided by a clinically proven method. Results: Using 111 clinical C-arm images and {+-}10 deg. and {+-}10 mm random perturbation around the ground-truth pose, a total of 2775 cases were evaluated. The average rotation and translation errors were 0.62 deg. (STD=0.31 deg.) and 0.72 mm (STD=0.55 mm) for the three-step filter and 0.67 deg. (STD=0.40 deg.) and 0.87 mm (STD=0.27 mm) using the line enhancement filter. Conclusions: The C-arm pose tracking method was sufficiently accurate and robust on human patient data for subsequent 3D implant reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In Situ Analysis of Laser Powder Bed Fusion Using Simultaneous High-Speed Infrared and X-ray Imaging

Laser powder bed fusion is a metal additive manufacturing technique that has received significant scientific and industrial attention over the past decades. However, the quality and reproducibility of parts manufactured by this technique is still a problem. Overcoming this issue requires an understanding of multiple complex physical phenomena which occur simultaneously during the process. Here, we illustrate a powerful new technique which synchronizes high-speed x-ray imaging with high-speed infrared imaging to study laser powder bed fusion processes in real time. Using this technique, we demonstrate the simultaneous observation of multiple phenomena including three-dimensional melt pool visualization, vapor plume dynamics, spatter formation, thermal history, and point cooling rates. The paired observation of these dynamic phenomena is critical to understanding the fundamentals of laser powder bed fusion, and the overall impact of process parameters on print quality.

36 MATERIALS SCIENCE↗

Risk-Based Explosion Assessment Internal Explosion of Exploration Upper Stage in Vehicle Assembly Building

This paper presents risk-based explosion analyses used to determine if an explosion of NASA's Space Launch System (SLS) Exploration Upper Stage (EUS) during fueling in Vehicle Assembly Building (VAB) High Bay 4 can hazard the Space Launch System (SLS) being processed in Bay 3. This paper focuses on blast fragmentation as it was the controlling hazard. An estimate of the amount of Net Explosion Weight (NEW) was used to develop a fragment list (mass, shape, takeoff velocity/angle) given an explosion occurs at ground level in Bay 4. Intervening superstructure that exists between Bay 4 and Bay 3 (that could potentially block EUS fragments) was modeled based on detailed visual images (VISSIM) and AUTOCAD/structural drawings. The fragment list was input to a 3D trajectory application that performs multiple random explosion simulations; each simulation varying fragment ballistic coefficient and takeoff angle/velocity. Individual fragments are tracked until stopped by the intervening superstructure or reach Bay 3, potentially impacting the SLS. The probability of impacting the SLS is then determined from the random simulations; the results are used to help decision-makers determine the efficacy of co-processing within the VAB and decide what mitigations may be appropriate.

Explosion Assessment↗

Performance of Compact Pulsed Thermal Imaging System for In-Service Applications. Pulsed thermal tomography nondestructive examination of additively manufactured reactor materials and components

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of complex topology nuclear reactor parts from high-strength corrosion resistance alloys, such as stainless steel and Inconel. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which has the capability of melting metallic powder and net shaping the structures with relatively high precision. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to creep in high temperature nuclear reactor environment. Currently, there exist limited capabilities to evaluate actual AM structures nondestructively. Pulsed Thermography (PT) imaging provides a capability for non-destructive evaluation (NDE) of sub-surface defects in arbitrary size structures. The PT method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PT method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. The data cube of PT measurements consists of surface temperature taken at sequential time intervals T(x,y,t). Material defects can be detected either by analyzing the thermograms T(x,y,t) data cube, or by using thermal tomography (TT) algorithm to obtain 3D spatial reconstruction of thermal effusivity e(x,y,z). To reduce the cost and enable in-service NDE in spatially constrained environment, it is highly desirable to develop PT with compact and inexpensive IR camera. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact PT system can also be used for in-service nondestructive evaluation (NDE) applications. However, data cube obtained with PT based on compact IR camera suffers from strong thermal noises and loss of features due to relatively low sampling rate. In this report we describe two unsupervised machine learning (ML) algorithms for enhancement of PT images obtained with compact IR camera. In one approach, we introduce Sparse Coding Discrete Cosine Transform (SC/DCT) algorithm to remove additive white Gaussian noise (AWGN) from spatial thermal effusivity reconstructions. In another approach we introduce a Spatial Temporal Denoised Thermal Source Separation (STDTSS) ML algorithm to process thermograms. The STDTSS algorithm consists of spatial and temporal denoising using Gaussian and Savitzky–Golay filtering, followed by the matrix decomposition using Principal Component Analysis (PCA), and Independent Component Analysis (ICA) to automatically detect flaws. In the work described in this report, we constructed a compact PT system using a relatively small and low-cost FLIR A65 camera, consisting on uncooled microbolometer detector. Performance of SC/DCT algorithm was demonstrated on enhancing TT images of Inconel 718 AM plate. Performance of the STDTSS methods was investigated using thermography data obtained from imaging stainless steel 316L specimens produced with LPBF method with imprinted calibrated porosity defects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparison of automated chemical-guided segmentation and human annotation of soil organic matter in X-ray microcomputed tomography imaging in contrasted soil types

Soil organic matter (OM) formation and persistence is strongly influenced by the spatial distribution of organic substrates and microscale soil heterogeneity by dictating OM accessibility to microorganisms. However, traditional size and/or density fractionation techniques disrupt aggregate architecture, eliminating spatial information needed to fully understand intra-aggregate OM distribution. To quantify three-dimensional OM spatial distribution and automate segmentation in X-ray microcomputed tomography (µCT) imaging without human annotation bias, we developed an iodine gas vapor (I2) based staining workflow that eliminates labor-intensive manual annotation while maintaining segmentation accuracy, using aggregates from four taxonomically diverse soils (Xerofluvent, Haploxeroll Sphagnofibrist, Palehumult) with an 8-fold range of soil organic carbon. Human annotation of 10 µCT slices by the experienced and inexperienced annotators resulted in variations up to 3% in the Dice similarity coefficient (DSC), reflecting a degree of inherent subjectivity of manual labeling. Such inconsistencies are expected to compound as the number of manually annotated slices increases. Dual-energy µCT imaging at 33.1 keV (below the iodine (I) K-edge) and 33.2 keV (above the I K-edge) was used to resolve aggregate microstructure following I2 staining. The automated image subtraction pipeline identified OM regions by the I Kedge induced brightness increases, achieving DSC values of 0.58–0.83 relative to an experienced annotator. Sensitivity analyses revealed that the reconstruction alpha value—optimized via the open-source tool TomocuPy—and the 3D registration slice count were the primary determinants of accuracy, providing a novel benchmark for dual-energy soil imaging. The pipeline without GPU acceleration achieved 9.6 to 43.2 times faster than manual annotation. Using GPU-accelerated image post-processing and affine transformation matrices, the pipeline successfully segmented OM elements for large-scale datasets (3232×3232 pixel, 2048 slices) within ~5200 s from raw file acquisition to segmented output. The high-throughput approach enables the quantification of OM spatial distribution across diverse and heterogeneous soil.

Soil microbial biomass↗

SU-E-I-74: Image-Matching Technique of Computed Tomography Images for Personal Identification: A Preliminary Study Using Anthropomorphic Chest Phantoms

Purpose: Fingerprints, dental impressions, and DNA are used to identify unidentified bodies in forensic medicine. Cranial Computed tomography (CT) images and/or dental radiographs are also used for identification. Radiological identification is important, particularly in the absence of comparative fingerprints, dental impressions, and DNA samples. The development of an automated radiological identification system for unidentified bodies is desirable. We investigated the potential usefulness of bone structure for matching chest CT images. Methods: CT images of three anthropomorphic chest phantoms were obtained on different days in various settings. One of the phantoms was assumed to be an unidentified body. The bone image and the bone image with soft tissue (BST image) were extracted from the CT images. To examine the usefulness of the bone image and/or the BST image, the similarities between the two-dimensional (2D) or threedimensional (3D) images of the same and different phantoms were evaluated in terms of the normalized cross-correlation value (NCC). Results: For the 2D and 3D BST images, the NCCs obtained from the same phantom assumed to be an unidentified body (2D, 0.99; 3D, 0.93) were higher than those for the different phantoms (2D, 0.95 and 0.91; 3D, 0.89 and 0.80). The NCCs for the same phantom (2D, 0.95; 3D, 0.88) were greater compared to those of the different phantoms (2D, 0.61 and 0.25; 3D, 0.23 and 0.10) for the bone image. The difference in the NCCs between the same and different phantoms tended to be larger for the bone images than for the BST images. These findings suggest that the image-matching technique is more useful when utilizing the bone image than when utilizing the BST image to identify different people. Conclusion: This preliminary study indicated that evaluating the similarity of bone structure in 2D and 3D images is potentially useful for identifying of an unidentified body.

60 APPLIED LIFE SCIENCES↗

Interrogating Solar Flare Loop Models with IRIS Observations 2: Plasma Properties, Energy Transport, and Future Directions

During solar flares a tremendous amount of magnetic energy is released and transported through the Sun’s atmosphere and out into the heliosphere. Despite over a century of study, many unresolved questions surrounding solar flares are still present. Among those are how does the solar plasma respond to flare energy deposition, and what are the important physical processes that transport that energy from the release site in the corona through the transition region and chromosphere? Attacking these questions requires the concert of advanced numerical simulations and high spatial-, temporal-, and spectral-resolution observations. While flares are 3D phenomenon, simulating the NLTE flaring chromosphere in 3D and performing parameter studies of 3D models is largely outwith our current computational capabilities. We instead rely on state-of-the-art 1D field-aligned simulations to study the physical processes that govern flares. Over the last decade, data from the Interface Region Imaging Spectrograph (IRIS) have provided the crucial observations with which we can critically interrogate the predictions of those flare loop models. Here in Paper 2 of a two-part review of IRIS and flare loop models, I discuss how forward modelling flares can help us understand the observations from IRIS, and how IRIS can reveal where our models do well and where we are likely missing important processes, focussing in particular on the plasma properties, energy transport mechanisms, and future directions of flare modelling.

solar flares↗

Fully Mechanically Controlled Automated Electron Microscopic Tomography

Knowledge of three-dimensional (3D) structures of each individual particles of asymmetric and flexible proteins is essential in understanding those proteins' functions; but their structures are difficult to determine. Electron tomography (ET) provides a tool for imaging a single and unique biological object from a series of tilted angles, but it is challenging to image a single protein for three-dimensional (3D) reconstruction due to the imperfect mechanical control capability of the specimen goniometer under both a medium to high magnification (approximately 50,000-160,000×) and an optimized beam coherence condition. Here, we report a fully mechanical control method for automating ET data acquisition without using beam tilt/shift processes. This method could reduce the accumulation of beam tilt/shift that used to compensate the error from the mechanical control, but downgraded the beam coherence. Our method was developed by minimizing the error of the target object center during the tilting process through a closed-loop proportional-integral (PI) control algorithm. The validations by both negative staining (NS) and cryo-electron microscopy (cryo-EM) suggest that this method has a comparable capability to other ET methods in tracking target proteins while maintaining optimized beam coherence conditions for imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Insights into the Morphology and Kinetics of Growth of Silver Metal–Organic Nanotubes

The kinetics of the formation of novel porous metal organic nanotubes, [Ag2(4,4 -(1,4-(xylene)diyl)bis- (1,2,4-triazole) (NO3)2] NMP, was investigated by means of ex-situ time-resolved small-angle X-ray scattering (SAXS) and scanning electron microscopy (SEM). The SAXS results were modeled using the Gualtieri model, which decouples the nucleation and growth processes giving additional insight into the crystal formation mechanism. The results show that the semirigid 4,4 -(1,4-(xylene)diyl)bis(1,2,4-triazole) ligand (L) binds with silver ions, adopting a seesaw geometry to form a polydisperse isotropic framework immediately after mixing the ligands and metal ions. In addition, the SEM imaging demonstrates that the microcrystals grow anisotropically, with nucleation along the edge of the 3D aggregate. These combined data demonstrate that the growth of this MONT occurs in two steps: a rapid formation of an isotropic porous structure immediately after mixing the reactant, which then develops anisotropically as the aggregates of nanorods grow in a preferred direction. The anisotropic growth of the crystal is autocatalytic and determined by the rate of nucleation of new growth sites on the crystals. Moreover, the results of this analysis elucidate, for the rst time, the exact order of the competing processes that occur in the synthesis of these MONTs, showing that their anisotropic growth occurs on the initial 3D aggregate and appears to be directed by the interplay between the surface energies that exist during the MONT formation process. This insight is crucial to the use of crystal engineering to guide the crystal formation processes in MONTs to targeted structures, properties, and applications.

36 MATERIALS SCIENCE↗

Using micro-XRF to characterize chloride ingress through cold joints in 3D printed concrete

Digital fabrication methods with concrete have been rapidly developing, with many problems related to component production and material control being solved in recent years. These processes produce inherently layered cementitious components that are anisotropic, and in many cases, produces a weak interface between layers, which are generally referred to as cold joints. While material strength at these interfaces has been well studied in recent years, durability has received less attention, even though cold joints can function as channels for aggressive agents, such as chlorides. This work presents a method using micro-X-ray fluorescence (μXRF) to image chloride ingress into layer interfaces of 3D printed fine-grained concrete specimens produced with varying layer deposition time intervals, and also compares it to neutron imaging of moisture uptake. The results show that cold joints formed after a 1 day time interval are highly susceptible to chloride ingress, and that curing conditions play a major role in how quickly interfacial transport can take place. The μXRF method is also shown to be useful for study of transport of chlorides in cold joints, due to its spatial resolution and direct analysis of an aggressive species of interest.

36 MATERIALS SCIENCE↗

A real-time applicator position monitoring system for gynecologic intracavitary brachytherapy

Purpose: To develop a real-time applicator position monitoring system (RAPS) for intracavitary brachytherapy using an infrared camera and reflective markers. Methods: 3D image-guided brachytherapy requires high accuracy of applicator localization; however, applicator displacement can happen during patient transfer for imaging and treatment delivery. No continuous applicator position monitoring system is currently available. The RAPS system was developed for real-time applicator position monitoring without additional radiation dose to patients. It includes an infrared camera, reflective markers, an infrared illuminator, and image processing software. After reflective markers are firmly attached to the applicator and the patient body, applicator displacement can be measured by computing the relative change in distance between the markers. The reflective markers are magnetic resonance imaging (MRI) compatible, which is suitable for MRI-guided HDR brachytherapy paradigm. In our prototype, a Microsoft Kinect sensor with a resolution of 640 by 480 pixels is used as an infrared camera. A phantom study was carried out to compare RAPS' measurements with known displacements ranging from −15 to +15 mm. A reproducibility test was also conducted. Results: The RAPS can achieve 4 frames/s using a laptop with Intel{sup ®} Core™2 Duo processor. When the pixel size is 0.95 mm, the difference between RAPS' measurements and known shift values varied from 0 to 0.8 mm with the mean value of 0.1 mm and a standard deviation of 0.44 mm. The system reproducibility was within 0.6 mm after ten reposition trials. Conclusions: This work demonstrates the feasibility of a real-time infrared camera based gynecologic intracavitary brachytherapy applicator monitoring system. Less than 1 mm accuracy is achieved when using an off-the-shelf infrared camera.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acquisition of quantitative physiological data and computerized image reconstruction using a single scan TV system

Single scan operation of television X-ray fluoroscopic systems allow both analog and digital reconstruction of tomographic sections from single plan images. This type of system combined with a minimum of statistical processing showed excellent capabilities for delineating small changes in differential X-ray attenuation. Patient dose reduction is significant when compared to normal operation or film recording. Flat screen, low light level systems were both rugged and light in weight, making them applicable for a variety of special purposes. Three dimensional information was available from the tomographic methods and the recorded data was sufficient when used with appropriate computer display devices to give representative 3D images.

Baily, N. A.↗

Deep reinforcement learning of cell movement in the early stage of C.elegans embryogenesis

Motivation: Cell movement in the early phase of Caenorhabditis elegans development is regulated by a highly complex process in which a set of rules and connections are formulated at distinct scales. Previous efforts have demonstrated that agent-based, multi-scale modeling systems can integrate physical and biological rules and provide new avenues to study developmental systems. However, the application of these systems to model cell movement is still challenging and requires a comprehensive understanding of regulatory networks at the right scales. Recent developments in deep learning and reinforcement learning provide an unprecedented opportunity to explore cell movement using 3D time-lapse microscopy images. Results: We present a deep reinforcement learning approach within an agent-based modeling system to characterize cell movement in the embryonic development of C.elegans. Our modeling system captures the complexity of cell movement patterns in the embryo and overcomes the local optimization problem encountered by traditional rule-based, agent-based modeling that uses greedy algorithms. Here, we tested our model with two real developmental processes: the anterior movement of the Cpaaa cell via intercalation and the rearrangement of the superficial left-right asymmetry. In the first case, the model results suggested that Cpaaa’s intercalation is an active directional cell movement caused by the continuous effects from a longer distance (farther than the length of two adjacent cells), as opposed to a passive movement caused by neighbor cell movements. In the second case, a leader-follower mechanism well explained the collective cell movement pattern in the asymmetry rearrangement. These results showed that our approach to introduce deep reinforcement learning into agent-based modeling can test regulatory mechanisms by exploring cell migration paths in a reverse engineering perspective. Lastly, this model opens new doors to explore the large datasets generated by live imaging. Availability and implementation: Source code is available at https://github.com/zwang84/drl4cellmovement.

59 BASIC BIOLOGICAL SCIENCES↗

A convolution-superposition dose calculation engine for GPUs

Purpose: Graphic processing units (GPUs) are increasingly used for scientific applications, where their parallel architecture and unprecedented computing power density can be exploited to accelerate calculations. In this paper, a new GPU implementation of a convolution/superposition (CS) algorithm is presented. Methods: This new GPU implementation has been designed from the ground-up to use the graphics card's strengths and to avoid its weaknesses. The CS GPU algorithm takes into account beam hardening, off-axis softening, kernel tilting, and relies heavily on raytracing through patient imaging data. Implementation details are reported as well as a multi-GPU solution. Results: An overall single-GPU acceleration factor of 908x was achieved when compared to a nonoptimized version of the CS algorithm implemented in PlanUNC in single threaded central processing unit (CPU) mode, resulting in approximatively 2.8 s per beam for a 3D dose computation on a 0.4 cm grid. A comparison to an established commercial system leads to an acceleration factor of approximately 29x or 0.58 versus 16.6 s per beam in single threaded mode. An acceleration factor of 46x has been obtained for the total energy released per mass (TERMA) calculation and a 943x acceleration factor for the CS calculation compared to PlanUNC. Dose distributions also have been obtained for a simple water-lung phantom to verify that the implementation gives accurate results. Conclusions: These results suggest that GPUs are an attractive solution for radiation therapy applications and that careful design, taking the GPU architecture into account, is critical in obtaining significant acceleration factors. These results potentially can have a significant impact on complex dose delivery techniques requiring intensive dose calculations such as intensity-modulated radiation therapy (IMRT) and arc therapy. They also are relevant for adaptive radiation therapy where dose results must be obtained rapidly.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effects of rapid thermal annealing on the structural and local atomic properties of ZnO: Ge nanocomposite thin films

We have investigated the structural and local atomic properties of Ge nanocrystals (Ge-ncs) embedded ZnO (ZnO: Ge) thin films. The films were deposited by sequential sputtering of ZnO and Ge thin film layers on z-cut quartz substrates followed by an ex-situ rapid thermal annealing (RTA) at 600 °C for 30, 60, and 90 s under forming gas atmosphere. Effects of RTA time on the evolution of Ge-ncs were investigated by x-ray diffraction (XRD), scanning electron microscopy (SEM), hard x-ray photoelectron spectroscopy (HAXPES), and extended x-ray absorption fine structure (EXAFS). XRD patterns have clearly shown that fcc diamond phase Ge-ncs of sizes ranging between 18 and 27 nm are formed upon RTA and no Ge-oxide peak has been detected. However, cross-section SEM images have clearly revealed that after RTA process, Ge layers form varying size nanoclusters composed of Ge-ncs regions. EXAFS performed at the Ge K-edge to probe the local atomic structure of the Ge-ncs has revealed that as prepared ZnO:Ge possesses Ge-oxide but subsequent RTA leads to crystalline Ge structure without the oxide layer. In order to study the occupied electronic structure, HAXPES has been utilized. The peak separation between the Zn 2p and Ge 3d shows no significant change due to RTA. This implies little change in the valence band offset due to RTA.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-Energy X-ray Tomographic Analysis of Precursor Metal Powders (Ti-6Al-4V) Used for Additive Manufacturing

We utilized high-energy x-ray tomography to characterize Ti-6Al-4V metal powders (both as-received and recycled) used in powder-bed additive manufacturing process. The image processing workflow was developed to process and analyze large amount of data objectively by computer program. The distribution of size and shape of the metal particles as well as defect (mainly porosity) inside the particles was analyzed with the statistical representation and resolution in micrometer. The result revealed that circular-shaped porosity with various sizes could be embedded in the powder particles. These porosities could potentially be transferred to the 3D printed part and critically affect the mechanical performance of the component. The present study shows the effectiveness of characterizing metal powders using x-ray imaging techniques where sufficient number of particles can be sampled within tens of minutes with a minimum sample preparation and high accuracy. Clear structural differences in the as-received and recycled powders were delineated that helps in determining the feasibility of using the recycled powders.

36 MATERIALS SCIENCE↗

Complete Tem-Tomography: 3D Structure of Gems Cluster

GEMS (glass with embedded metal and sulfide) grains in interplanetary dust particles (IDPs) are considered to be one of the ubiquitous and fundamental building blocks of solids in the Solar System. They have been considered to be interstellar silicate dust that survived various metamorphism or alteration processes in the protoplanetary disk but the elemental and isotopic composition measurements suggest that most of them have been formed in the protoplanetary disk as condensates from high temperature gas. This formation model is also supported by the formation of GEMS-like grains with respect to the size, mineral assemblage, texture and infrared spectrum by condensation experiments from mean GEMS composition materials. Previous GEMS studies were performed only with 2D observation by transmission electron microscopy (TEM) or scanning TEM (STEM). However, the 3D shape and structure of GEMS grains and the spatial distribution of Fe/FeS's has critical information about their formation and origin. Recently, the 3D structure of GEMS grains in ultrathin sections of cluster IDPs was revealed by electron tomography using a TEM/STEM (JEM-2100F, JEOL). However, CT images of thin sections mounted on Cu grids acquired by conventional TEM-tomography are limited to low tilt angles (e. g., less than absolute value of 75 deg. In fact, previous 3D TEM observations of GEMS were affected by some artifacts related to the limited tilt range in the TEM used. Complete tomographic images should be acquired by rotating the sample tilt angle over a range of more than absolute value of 80 deg otherwise the CT images lose their correct structures. In order to constrain the origin and formation process of GEMS grains more clearly, we performed complete electron tomography for GEMS grains. Here we report the sample preparation method we have developed for this study, and the preliminary results.

Matsuno, J.↗

SU-F-E-13: Design and Fabrication of Gynacological Brachytherapy Shielding & Non Shielding Applicators Using Indigenously Developed 3D Printing Machine

Purpose: In this innovative work we have developed Gynecological Brachytherapy shielding & Non Shielding Applicators and compared with the commercially available applicators by using the indigenously developed 3D Printing machine. Methods: We have successfully indigenously developed the 3D printing machine. Which contain the 3 dimensional motion platform, Heater unit, base plate, ect… To fabricate the Gynecological Brachytherapy shielding & non shielding applicators the 3D design were developed in the computer as virtual design. This virtual design is made in a CAD computer file using a 3D modeling program. Separate programme for the shielding & non shielding applicators. We have also provided the extra catheter insert provision in the applicator for the multiple catheter. The DICOM file of the applicator were then converted to stereo Lithography file for the 3D printer. The shielding & Non Shielding Applicators were printed on a indigenously developed 3D printer material. The same dimensions were used to develop the applicators in the acrylic material also for the comparative study. A CT scan was performed to establish an infill-density calibration curve as well as characterize the quality of the print such as uniformity and the infill pattern. To commission the process, basic CT and dose properties of the printing materials were measured in photon beams and compared against water and soft tissue. Applicator were then scanned to confirm the placement of multiple catheter position. Finally dose distributions with rescanned CTs were compared with those computer-generated applicators. Results: The doses measured from the ion Chamber and X-Omat film test were within 2%. The shielded applicator reduce the rectal dose comparatively with the non shielded applicator. Conclusion: As of submission 3 unique cylinders have been designed, printed, and tested dosimetrically. A standardizable workflow for commissioning custom 3D printed applicators was codified and will be reported.

60 APPLIED LIFE SCIENCES↗