Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Soft X-ray Tomography Reveals HSV-1-Induced Remodeling of Human B Cells

Upon infection, viruses hijack the cell machinery and remodel host cell structures to utilize them for viral proliferation. Since viruses are about a thousand times smaller than their host cells, imaging virus-host interactions at high spatial resolution is like looking for a needle in a haystack. Scouting gross cellular changes with fluorescent microscopy is only possible for well-established viruses, where fluorescent tagging is developed. Soft X-ray tomography (SXT) offers 3D imaging of entire cells without the need for chemical fixation or labeling. Here, we use full-rotation SXT to visualize entire human B cells infected by the herpes simplex virus 1 (HSV-1). We have mapped the temporospatial remodeling of cells during the infection and observed changes in cellular structures, such as the presence of cytoplasmic stress granules and multivesicular structures, formation of nuclear virus-induced dense bodies, and aggregates of capsids. Our results demonstrate the power of SXT imaging for scouting virus-induced changes in infected cells and understanding the orchestration of virus-host remodeling quantitatively.

59 BASIC BIOLOGICAL SCIENCES↗

A new fluorescence/PET probe for targeting intracellular human telomerase reverse transcriptase (hTERT) using Tat peptide-conjugated IgM

Despite an increasing need for methods to visualize intracellular proteins in vivo, the majority of antibody-based imaging methods available can only detect membrane proteins. The human telomerase reverse transcriptase (hTERT) is an intracellular target of great interest because of its high expression in several types of cancer. In this study, we developed a new probe for hTERT using the Tat peptide. An hTERT antibody (IgG or IgM) was conjugated with the Tat peptide, a fluorescence dye and {sup 64}Cu. HT29 (hTERT+) and U2OS (hTERT−) were used to visualize the intracellular hTERT. The hTERT was detected by RT-PCR and western blot. Fluorescence signals for hTERT were obtained by confocal microscopy, live cell imaging, and analyzed by Tissue-FAXS. In nude mice, tumors were visualized using the fluorescence imaging devices Maestro™ and PETBOX. In RT-PCR and western blot, the expression of hTERT was detected in HT29 cells, but not in U2OS cells. Fluorescence signals were clearly observed in HT29 cells and in U2OS cells after 1 h of treatment, but signals were only detected in HT29 cells after 24 h. Confocal microscopy showed that 9.65% of U2OS and 78.54% of HT29 cells had positive hTERT signals. 3D animation images showed that the probe could target intranuclear hTERT in the nucleus. In mice models, fluorescence and PET imaging showed that hTERT in HT29 tumors could be efficiently visualized. In summary, we developed a new method to visualize intracellular and intranuclear proteins both in vitro and in vivo. - Highlights: • We developed new probes for imaging hTERT using Tat-conjugated IgM antibodies labeled with a fluorescent dye and radioisotope. • This probes could be used to overcome limitation of conventional antibody imaging system in live cell imaging. • This system could be applicable to monitor intracellular and intranuclear proteins in vitro and in vivo.

60 APPLIED LIFE SCIENCES↗

VERA and VERA-EDU 3.5 Release Notes

The Virtual Environment for Reactor Applications components included in this distribution include selected computational tools and supporting infrastructure that solve neutronics, thermal-hydraulics, fuel performance, and coupled neutronics-thermal hydraulics problems. The infrastructure components provide a simplified common user input capability and provide for the physics integration with data transfer and coupled-physics iterative solution algorithms. Neutronics analysis can be performed for 2D lattices, 2D core and 3D core problems for pressurized water reactor geometries that can be used to calculate criticality and fission rate distributions by pin for input fuel compositions. MPACT uses the Method of Characteristics transport approach for 2D problems. For 3D problems, MPACT uses the 2D/1D method which uses 2D MOC in a radial plane and diffusion or SPn in the axial direction. MPACT includes integrated cross section capabilities that provide problem-specific cross sections generated using the subgroup methodology. The code can be executed both 2D and 3D problems in parallel to reduce overall run time. A thermal-hydraulics capability is provided with CTF (an updated version of COBRA-TF) that allows thermal-hydraulics analyses for single and multiple assemblies using the simplified VERA common input. This distribution also includes coupled neutronics/thermal-hydraulics capabilities to allow calculations using MPACT coupled with CTF. The VERA fuel rod performance component BISON calculates, on a 2D or 3D basis, fuel rod temperature, fuel rod internal pressure, free gas volume, clad integrity and fuel rod waterside diameter. These capabilities allow simulation of power cycling, fuel conditioning and deconditioning, high burnup performance, power uprate scoping studies, and accident performance. Input/Output capabilities include the VERA Common Input (VERAIn) script which converts the ASCII common input file to the intermediate XML used to drive all of the physics codes in the VERA Core Simulator (VERA-CS). VERA component codes either input the VERA XML format directly, or provide a preprocessor which can convert the XML into native input. VERAView is an interactive graphical interface for the visualization and engineering analyses of output data from VERA. The python-based software is easy to install and intuitive to use, and provides instantaneous 2D and 3D images, 1D plots, and alpha-numeric data from VERA multi-physics simulations. Testing within CASL has focused primarily on Westinghouse four-loop reactor geometries and conditions with example problems included in the distribution.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hierarchical streamline bundles for visualizing 2D flow fields.

We present hierarchical streamline bundles, a new approach to simplifying and visualizing 2D flow fields. Our method first densely seeds a flow field and produces a large number of streamlines that capture important flow features such as critical points. Then, we group spatially neighboring and geometrically similar streamlines to construct a hierarchy from which we extract streamline bundles at different levels of detail. Streamline bundles highlight multiscale flow features and patterns through a clustered yet non-cluttered display. This selective visualization strategy effectively accentuates visual foci and therefore is able to convey the desired insight into the flow fields. The hierarchical streamline bundles we have introduced offer a new way to characterize and visualize the flow structure and patterns in multiscale fashion. Streamline bundles highlight critical points clearly and concisely. Exploring the hierarchy allows a complete visualization of important flow features. Thanks to selective streamline display and flexible LOD refinement, our multiresolution technique is scalable and is promising for viewing large and complex flow fields. In the future, we would like to seek a cost-effective way to generate streamlines without enforcing the dense seeding condition. We will also extend this approach to handle real-world 3D complex flow fields.

99 GENERAL AND MISCELLANEOUS↗

SU-E-J-229: Magnetic Resonance Imaging of Small Fiducial Markers for Proton Beam Therapy

Purpose: For proton beam therapy, small fiducial markers are preferred for patient alignment due to less interference with the proton beam. Visualizing small fiducial markers can be challenging in MRI. This study intends to investigate MRI imaging protocols for better visualization of small fiducial markers. Methods: Two carbon and two coil-shaped gold markers were placed into a gel phantom. Both carbon markers had a diameter of 1mm and a length of 3mm. Both gold markers had a length of 5mm. One gold marker had a diameter of 0.5mm and the other had a diameter of 0.75mm. T1 VIBE, T2 SPACE, TrueFISP and susceptibility weighted (SW) images were acquired. To improve marker contrast, high spatial resolution was used to reduce partial volume effect. Slice thickness was 1.5mm for all four sequences and in-plane resolution was 0.6mm for TrueFISP, 0.7mm for T1 VIBE, and 0.8mm for T2 SPACE and SW. For comparison purpose, a 3D T1 VIBE image set at 3mm slice thickness and 1.2mm in-plane resolution was also acquired. Results: All markers were visible in all high-resolution image sets. In each image set, marker-induced signal void was the smallest (in diameter) for carbon markers, followed by the 0.5mm gold marker and the largest for the 0.75mm gold marker. The SW images had the largest marker-induced signal void. However, those might be confused by susceptibility-gradient-induced signal voids. T1 VIBE had good visualization of markers with nicely defined edges. T2 SPACE had reasonable visualization of markers but edges were slightly blurred. TrueFISP had good visualization of markers only if they were not masked by banding artifacts. As a comparison, all markers were hardly visible in the standard resolution T1 VIBE images. Conclusion: 3D high-resolution T1 VIBE and SW have great potential in providing good visualization of small fiducial markers for proton beam therapy.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP2-12: Quantification of 3D Geometric Distortion for 1.5T and 3T MRI Scanners Used for Radiation Therapy

Purpose: To quantify the magnitude of geometric distortion for MRI scanners and provide recommendations for MRI imaging for radiation therapy Methods: A novel phantom, QUASAR MRID3D [Modus Medical Devices Inc.], was scanned to evaluate the level of 3D geometric distortion present in five MRI scanners used for radiation therapy in our department. The phantom was scanned using the body coil with 1mm image slice thickness to acquire 3D images of the phantom body. The phantom was aligned to its geometric center for each scan, and the field of view was set to visualize the entire phantom. The dependence of distortion magnitude with distance from imaging isocenter and with magnetic field strength (1.5T and 3T) was investigated. Additionally, the characteristics of distortion for Siemens and GE machines were compared. The image distortion for each scanner was quantified in terms of mean, standard deviation (STD), maximum distortion, and skewness. Results: The 3T and 1.5T scans show a similar absolute distortion with a mean of 1.38mm (0.33mm STD) for 3T and 1.39mm (0.34mm STD) for 1.5T for a 100mm radius distance from isocenter. Some machines can have a distortion larger than 10mm at a distance of 200mm from the isocenter. The distortions are presented with plots of the x, y, and z directional components. Conclusion: The results indicate that quantification of MRI image distortion is crucial in radiation oncology for target and organ delineation and treatment planning. The magnitude of geometric distortion determines the margin needed for target contouring which is usually neglected in treatment planning process, especially for SRS/SBRT treatments. Understanding the 3D distribution of the MRI image distortion will improve the accuracy of target delineation and, hence, treatment efficacy. MRI imaging with proper patient alignment to the isocenter is vital to reducing the effects of MRI distortion in treatment planning.

60 APPLIED LIFE SCIENCES↗

Optimal arrangement of structural and functional parts in a flat plate integrated collector storage solar water heater (ICSSWH)

Parameters that affect the efficiency of a flat plate integrated collector storage solar water heater (ICSSWH) are examined experimentally and numerically. This specific ICSSWH contains water that is not refreshed. The service water is heated indirectly through an immersed heat exchanger (HE) in contact with the front and back major surfaces. A forced convection mechanism consisting of a pump that brings the storage water into motion by recirculation is used for heat transfer intensification. The two major (front and back) flat plate surfaces need to be well interconnected so that they are not deformed by the weight of the contained water and the exerted high-pressure. Two main factors that influence the performance are optimized: the position and size of the recirculation ports and the arrangement and size of the interconnecting fins. Both factors are explored to maximize the velocity flow field of the recirculated storage water. Consequently, the heat transfer rate between the two water circuits is maintained at high levels. Various 3D computational fluid dynamics (CFD) models are developed using the FLUENT package. An experimental model, made by Plexiglas, is used for the visualization of the flow field. Flow velocities are measured using a laser doppler velocimetry (LDV) system. The optimal arrangement increases the mean storage water velocity by 65% and raises the outlet temperatures up to 8 C. (author)

14 SOLAR ENERGY↗

Evaluating the pressure dependence of PZT structures using a virtual reality environment

Pb–Zr–Ti–O (PZT) perovskites span a large solid-solution range and have found widespread use due to their piezoelectric and ferroelectric properties that also span a large range. Crystal structure analysis via Rietveld refinement facilitates materials analysis via the extraction of the structural parameters. These parameters, often obtained as a function of an additional dimension (e.g., pressure), can help to diagnose materials response within a use environment. Often referred to as “ in-situ ” studies, these experiments provide an abundance of data. Viewing structural changes due to applied pressure conditions can give much-needed insight into materials performance. However, challenges exist for viewing/presenting results when the details are inherently three-dimensional (3D) in nature. For PZT perovskites, the use of polyhedra (e.g., Zr/Ti–O 6 octahedra) to view bonding/connectivity is beneficial; however, the visualization of the octahedra behavior with pressure dependence is less easily demonstrated due to the complexity of the added pressure dimension. We present a more intuitive visualization by projecting structural data into virtual reality (VR). We employ previously published structural data for Pb 0.99 (Zr 0.95 Ti 0.05 ) 0.98 Nb 0.02 O 3 as an exemplar for VR visualization of the PZT R3c crystal structure between ambient and 0.62 GPa pressure. This is accomplished via our in-house CAD2VR™ software platform and the new CrystalVR plugin. The use of the VR environment enables a more intuitive viewing experience, while enabling on-the-fly evaluation of crystal data, to form a detailed and comprehensive understanding of in-situ datasets. Discussion of methodology and tools for viewing are given, along with how recording results in video form can enable the viewing experience.

Rodriguez, Mark A. (ORCID:0000000269405044)↗

Discovering invariant spatial features in electron energy loss spectroscopy images on the mesoscopic and atomic levels

Over the last two decades, Electron Energy Loss Spectroscopy (EELS) imaging with a scanning transmission electron microscope has emerged as a technique of choice for visualizing complex chemical, electronic, plasmonic, and phononic phenomena in complex materials and structures. The availability of the EELS data necessitates the development of methods to analyze multidimensional data sets with complex spatial and energy structures. Traditionally, the analysis of these data sets has been based on analysis of individual spectra, one at a time, whereas the spatial structure and correlations between individual spatial pixels containing the relevant information of the physics of underpinning processes have generally been ignored and analyzed only via the visualization as 2D maps. Here, we develop a machine learning-based approach and workflows for the analysis of spatial structures in 3D EELS data sets using a combination of dimensionality reduction and multichannel rotationally invariant variational autoencoders. This approach is illustrated for the analysis of both the plasmonic phenomena in a system of nanowires and in the core excitations in functional oxides using low loss and core-loss EELS, respectively. The code developed in this manuscript is open sourced and freely available and provided as a Jupyter notebook for the interested reader.

36 MATERIALS SCIENCE↗

3D Simulation of External Flooding Events for the RISMC Pathway

Incorporating 3D simulations as part of the Risk-Informed Safety Margins Characterization (RISMIC) Toolkit allows analysts to obtain a more complete picture of complex system behavior for events including external plant hazards. External events such as flooding have become more important recently – however these can be analyzed with existing and validated simulated physics toolkits. In this report, we describe these approaches specific to flooding-based analysis using an approach called Smoothed Particle Hydrodynamics. The theory, validation, and example applications of the 3D flooding simulation are described. Integrating these 3D simulation methods into computational risk analysis provides a spatial/visual aspect to the design, improves the realism of results, and can prove visual understanding to validate the analysis of flooding.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design and Testing of the Vortex Ring Facility

This document summarizes the efforts of building an experimental test facility to study the evolution of the cloud following a nuclear detonation above ground level and support the development of numerical models to describe it. The experimental facility allows nonintrusive flow visualization and measurements of buoyant vortex ring formation and evolution using background-oriented Schlieren and particle image velocimetry techniques. In addition, 3D unsteady computational fluid dynamics simulations using unsteady Reynolds-averaged Navier–Stokes and volume-of-fluid numerical methods were performed to support the experimental design as well as to provide insight about the formation and evolution of the vortex ring.

42 ENGINEERING↗

Multi-Scale Characterization of Porosity and Cracks in Silicon Carbide Cladding after Transient Reactor Test Facility Irradiation

Silicon carbide (SiC) ceramic matrix composite (CMC) cladding is currently being pursued as one of the leading candidates for accident-tolerant fuel (ATF) cladding for light water reactor applications. The morphology of fabrication defects, including the size and shape of voids, is one of the key challenges that impacts cladding performance and guarantees reactor safety. Therefore, quantification of defects’ size, location, distribution, and leak paths is critical to determining SiC CMC in-core performance. This research aims to provide quantitative insight into the defect’s distribution under multi-scale characterization at different length scales before and after different Transient Reactor Test Facility (TREAT) irradiation tests. A non-destructive multi-scale evaluation of irradiated SiC will help to assess critical microstructural defects from production and/or experimental testing to better understand and predict overall cladding performance. X-ray computed tomography (XCT), a non-destructive, data-rich characterization technique, is combined with lower length scale electronic microscopic characterization, which provides microscale morphology and structural characterization. This paper discusses a fully automatic workflow to detect and analyze SiC-SiC defects using image processing techniques on 3D X-ray images. Following the XCT data analysis, advanced characterizations from focused ion beam (FIB) and transmission electron microscopy (TEM) were conducted to verify the findings from the XCT data, especially quantitative results from local nano-scale TEM 3D tomography data, which were utilized to complement the 3D XCT results. In this work, three SiC samples (two irradiated and one unirradiated) provided by General Atomics are investigated. The irradiated samples were irradiated in a way that was expected to induce cracking, and indeed, the automated workflow developed in this work was able to successfully identify and characterize the defects formation in the irradiated samples while detecting no observed cracking in the unirradiated sample. These results demonstrate the value of automated XCT tools to better understand the damage and damage propagation in SiC-SiC structures for nuclear applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Coupling Visualization and Data Analysis for Knowledge Discovery from Multi-dimensional Scientific Data

Knowledge discovery from large and complex scientific data is a challenging task. With the ability to measure and simulate more processes at increasingly finer spatial and temporal scales, the growing number of data dimensions and data objects presents tremendous challenges for effective data analysis and data exploration methods and tools. The combination and close integration of methods from scientific visualization, information visualization, automated data analysis, and other enabling technologies"such as efficient data management" supports knowledge discovery from multi-dimensional scientific data. This paper surveys two distinct applications in developmental biology and accelerator physics, illustrating the effectiveness of the described approach.

97 MATHEMATICS AND COMPUTING↗

Tomo2Mesh: Fast Reconstruction and Visualization of Tomography Data in Mesh Format

Tomo2Mesh is an open-source project targeted towards real-time reconstruction, segmentation, and visualization of computed tomography (CT) data in mesh format. The CT reconstruction scheme is based on filtered back-projection of voxel subsets. The segmentation scheme uses a 3D convolutional neural network. To allow for fast, real-time reconstruction, voxel subsets are first identified by coarse reconstruction. The detail in specific regions of interest is improved through full reconstruction of voxel subsets in that region. Data structures are implemented to store and process voxel subsets. Finally, voxel data is labeled using connected components to detect disconnected regions such as voids whose morphological attributes (e.g., Feret diameter, principal axis orientation, local number density, size, etc.) can be measured also in real-time. Finally, a fast marching cubes implementation processes labeled voxel data into a triangular face mesh (vertices and faces) in .ply format for visualization in Paraview or other mesh visualization tools. The code provides a simple programming interface for detecting, classifying, and visualizing regions of interest based on morphology. For example, detected voids can be classified as round pores or extended cracks. Highly porous neighborhoods can be identified based on local number density. The mesh texture (or color) is assigned based these morphological attributes to allow smart visualization scenarios in real-time (e.g., show only long cracks). At the time of first release (July 2022), extraction of face mesh for visualization for raw CT data from a 2 megapixel camera would take between 1-5 minutes for most scenarios.

TEKAWADE, ANIKET↗

Engineering Graphene-Ceramic 3D Composite Foams by Freeze Drying

A 3D graphene foam produced by the chemical vapor deposition (CVD) technique is recognized as an effective nanofiller material, as it does not agglomerate in the matrix. Though CVD facilitates pristine graphene foam production, the method poses limitations in developing large-scale 3D graphene composite foams as advanced engineering materials. In this paper, a freeze-drying (FD) process is used to produce a composite 3D foam, which is a mixture of graphene nanoplatelet (GNP) and a low-temperature co-fired ceramic (LTCC). The freeze-dried GNP-LTCC reticulated 3D composite foam has an average pore size ranging from 70 to 100 μm. Pore size is varied by regulating the heat transfer rate during the freezing process using a thermally conductive aluminum (Al) mold and a thermally insulating acrylonitrile butadiene styrene (ABS) mold. Computational thermal modeling is used to visualize the heat transfer and its effect on foam pore size. Subsequently, a freeze-dried GNP-LTCC composite foam is embedded into the LTCC matrix to form a hierarchical assembly by a spark plasma technique without compromising the 3D structure of the FD foam. This study established that a simple, eco-friendly, and scalable processing methodology can produce advanced graphene-based 3D composite foams as the future tailorable nanofillers for designing multimatrix materials.

36 MATERIALS SCIENCE↗

VERAView User's Guide

VERAView has been developed as an interactive graphical interface for the visualization and engineering analyses of output data from VERA. The python-based software is easy to install and intuitive to use, and provides instantaneous 2D and 3D images, 1D plots, and alpha-numeric data from VERA multi-physics simulations. This document provides a brief overview of the software and some description of the major features of the application, including examples of each of the encapsulated ‘widgets’ that have been implemented thus far. VERAView is still under major development and large changes in the software and this document are still anticipated.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Machine Vision-based Robot Manipulators for Nuclear Applications - 20370

Decommissioning and dismantling of nuclear facilities are major challenges facing the nuclear industry. Robot manipulators with capabilities of restoring nuclear structures and significantly prolonging nuclear power generation in addition to their applications in decommissioning and dismantling (D and D) would immensely ease the above-mentioned challenge. Ability to remotely sense/monitor and analyze dangerous and hazardous environments such as nuclear reactors as well as performing reparatory tasks in such environments using robot manipulators require additional information from vision sensors. Structural sample collection and inspection as well as restoration require object and position information. Computer vision is used to obtain precise 3D position information. The current work uses the Sawyer robot with the integrated Cognex camera. The research presents an approach to facilitate and improve operations in a nuclear reactor using robotic vision control. The vision control system is modeled with Augmented Image Space-based visual servoing approach. Results showing accurate robot control. Object recognition is used to recognize the image and calculate it poses. To transform coordinates of the object's pose from the camera frame to the robotic frame transformation matrices are employed. Future work will employ a 3D camera (with depth information) using Denso robot. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Three dimensional fabric evolution of sheared sand

Granular particles undergo translation and rolling when they are sheared. This paper presents a three-dimensional (3D) experimental assessment of fabric evolution of sheared sand at the particle level. F-75 Ottawa sand specimen was tested under an axisymmetric triaxial loading condition. It measured 9.5 mm in diameter and 20 mm in height. The quantitative evaluation was conducted by analyzing 3D high-resolution x-ray synchrotron micro-tomography images of the specimen at eight axial strain levels. The analyses included visualization of particle translation and rotation, and quantification of fabric orientation as shearing continued. Representative individual particles were successfully tracked and visualized to assess the mode of interaction between them. This paper discusses fabric evolution and compares the evolution of particles within and outside the shear band as shearing continues. Changes in particle orientation distributions are presented using fabric histograms and fabric tensor.

36 MATERIALS SCIENCE↗