Search NASA⌕ Search

SEARCH · Search NASA

Results for “ARTIFACTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

SNIa Cosmology Analysis Results from Simulated LSST Images: From Difference Imaging to Constraints on Dark Energy

Abstract The Vera Rubin Observatory Legacy Survey of Space and Time (LSST) is expected to process ∼10 6 transient detections per night. For precision measurements of cosmological parameters and rates, it is critical to understand the detection efficiency, magnitude limits, artifact contamination levels, and biases in the selection and photometry. Here we rigorously test the LSST Difference Image Analysis (DIA) pipeline using simulated images from the Rubin Observatory LSST Dark Energy Science Collaboration Data Challenge (DC2) simulation for the Wide-Fast-Deep survey area. DC2 is the first large-scale (300 deg 2 ) image simulation of a transient survey that includes realistic cadence, variable observing conditions, and CCD image artifacts. We analyze ∼15 deg 2 of DC2 over a 5 yr time span in which artificial point sources from Type Ia supernova (SNIa) light curves have been overlaid onto the images. The magnitude limits per filter are u = 23.66 mag, g = 24.69 mag, r = 24.06 mag, i = 23.45 mag, z = 22.54 mag, and y = 21.62 mag. The artifact contamination levels are ∼90% of all detections, corresponding to ∼1000 artifacts deg –2 in g band, and falling to 300 deg –2 in y band. The photometry has biases <1% for magnitudes 19.5 < m < 23. Our DIA performance on simulated images is similar to that of the Dark Energy Survey difference-imaging pipeline on real images. We also characterize DC2 image properties to produce catalog-level simulations needed for distance bias corrections. We find good agreement between DC2 data and simulations for distributions of signal-to-noise ratio, redshift, and fitted light-curve properties. Applying a realistic SNIa cosmology analysis for redshifts z < 1, we recover the input cosmology parameters to within statistical uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

Symplectic maps for the n-body problem - Stability analysis

The stability of new symplectic n-body maps is examined from the point of view of nonlinear dynamics. The resonances responsible for the principal artifacts are identified. These are resonances between the stepsize and the difference of mean motions between pairs of planets. For larger stepsizes resonant perturbations are evident in the variation of the energy of the system corresponding to these stepsize resonances. It is shown that the principal instability of the method can be predicted and corresponds to the overlap of the stepsize resonances. It is noted that the analysis suggests that other artifacts will occur. For example, the overlap of a stepsize resonance with a resonance of the actual system may also give a region of chaotic behavior that is an artifact. It is pointed out that the fact that the principal artifacts corresponds to a particular set of stepsize resonances suggests that it may be possible to perturbatively remove the effect when the stepsize resonances are nonoverlapping.

Wisdom, Jack↗

Intelligent Agents for Design and Synthesis Environments: My Summary

This presentation gives a summary of intelligent agents for design synthesis environments. We'll start with the conclusions, and work backwards to justify them. First, an important assumption is that agents (whatever they are) are good for software engineering. This is especially true for software that operates in an uncertain, changing environment. The "real world" of physical artifacts is like that: uncertain in what we can measure, changing in that things are always breaking down, and we must interact with non-software entities. The second point is that software engineering techniques can contribute to good design. There may have been a time when we wanted to build simple artifacts containing little or no software. But modern aircraft and spacecraft are complex, and rely on a great deal of software. So better software engineering leads to better designed artifacts, especially when we are designing a series of related artifacts and can amortize the costs of software development. The third point is that agents are especially useful for design tasks, above and beyond their general usefulness for software engineering, and the usefulness of software engineering to design.

Norvig, Peter↗

Partial Automation of Requirements Tracing

Requirements Tracing on Target (RETRO) is software for after-the-fact tracing of textual requirements to support independent verification and validation of software. RETRO applies one of three user-selectable information-retrieval techniques: (1) term frequency/inverse document frequency (TF/IDF) vector retrieval, (2) TF/IDF vector retrieval with simple thesaurus, or (3) keyword extraction. One component of RETRO is the graphical user interface (GUI) for use in initiating a requirements-tracing project (a pair of artifacts to be traced to each other, such as a requirements spec and a design spec). Once the artifacts have been specified and the IR technique chosen, another component constructs a representation of the artifact elements and stores it on disk. Next, the IR technique is used to produce a first list of candidate links (potential matches between the two artifact levels). This list, encoded in Extensible Markup Language (XML), is optionally processed by a filtering component designed to make the list somewhat smaller without sacrificing accuracy. Through the GUI, the user examines a number of links and returns decisions (yes, these are links; no, these are not links). Coded in XML, these decisions are provided to a "feedback processor" component that prepares the data for the next application of the IR technique. The feedback reduces the incidence of erroneous candidate links. Unlike related prior software, RETRO does not require the user to assign keywords, and automatically builds a document index.

Hayes, Jane↗

On the Importance of Small Ice Crystals in Tropical Anvil Cirrus

In situ measurements of ice crystal concentrations and sizes made with aircraft instrumentation over the past two decades have often indicated the presence of numerous relatively small (< 50 m diameter) crystals in cirrus clouds. Further, these measurements frequently indicate that small crystals account for a large fraction of the extinction in cirrus clouds. The fact that the instruments used to make these measurements, such as the Forward Scattering Spectrometer Probe (FSSP) and the Cloud Aerosol Spectrometer (CAS), ingest ice crystals into the sample volume through inlets has led to suspicion that the indications of numerous small ]crystals could be artifacts of large ]crystal shattering on the instrument inlets. We present new aircraft measurements in anvil cirrus sampled during the Tropical Composition, Cloud, and Climate Coupling (TC4) campaign with the 2 ] Dimensional Stereo (2D ]S) probe, which detects particles as small as 10 m. The 2D ]S has detector "arms" instead of an inlet tube. Since the 2D ]S probe surfaces are much further from the sample volume than is the case for the instruments with inlets, it is expected that 2D ]S will be less susceptible to shattering artifacts. In addition, particle inter ]arrival times are used to identify and remove shattering artifacts that occur even with the 2D ]S probe. The number of shattering artifacts identified by the 2D ]S interarrival time analysis ranges from a negligible contribution to an order of magnitude or more enhancement in apparent ice concentration over the natural ice concentration, depending on the abundance of large crystals and the natural small ]crystal concentration. The 2D ]S measurements in tropical anvil cirrus suggest that natural small ]crystal concentrations are typically one to two orders of magnitude lower than those inferred from CAS. The strong correlation between the CAS/2D ]S ratio of small ]crystal concentrations and large ]crystal concentration suggests that the discrepancy is likely caused by shattering of large crystals on the CAS inlet. We argue that past measurements with CAS in cirrus with large crystals present may contain errors due to crystal shattering, and past conclusions derived from these measurements may need to be revisited. Further, we present correlations between CAS spurious concentration and 2D ]S large ]crystal mass from spatially uniform anvil cirrus sampling periods as an approximate guide for estimating quantitative impact of large ]crystal shattering on CAS concentrations in previous datasets. We use radiative transfer calculations to demonstrate that in the maritime anvil cirrus sampled during TC4, small crystals indicated by 2D ]S contribute relatively little cloud extinction, radiative forcing, or radiative heating in the anvils, regardless of anvil age or vertical location in the clouds. While 2D ]S ice concentrations in fresh anvil cirrus may often exceed 1 cm.3, and are observed to exceed 10 cm.3 in turrets, they are typically ~0.1 cm.3 and rarely exceed 1 cm.3 (<1.4% of the time) in aged anvil cirrus. We hypothesize that isolated occurrences of higher ice concentrations in aged anvil cirrus may be caused by ice nucleation driven by either small ]scale convection or gravity waves. It appears that the numerous small crystals detrained from convective updrafts do not persist in the anvil cirrus sampled during TC ]4.

Jensen, E. J.↗

Effects of Spatio-Temporal Aliasing on Out-the-Window Visual Systems

Designers of out-the-window visual systems face a challenge when attempting to simulate the outside world as viewed from a cockpit. Many methodologies have been developed and adopted to aid in the depiction of particular scene features, or levels of static image detail. However, because aircraft move, it is necessary to also consider the quality of the motion in the simulated visual scene. When motion is introduced in the simulated visual scene, perceptual artifacts can become apparent. A particular artifact related to image motion, spatiotemporal aliasing, will be addressed. The causes of spatio-temporal aliasing will be discussed, and current knowledge regarding the impact of these artifacts on both motion perception and simulator task performance will be reviewed. Methods of reducing the impact of this artifact are also addressed

image generator↗

Impact of Satellite Viewing-Swath Width on Global and Regional Aerosol Optical Thickness Statistics and Trends

We use the Moderate Resolution Imaging Spectroradiometer (MODIS) satellite aerosol optical thickness (AOT) product to assess the impact of reduced swath width on global and regional AOT statistics and trends. Alongtrack and across-track sampling strategies are employed, in which the full MODIS data set is sub-sampled with various narrow-swath (approximately 400-800 km) and single pixel width (approximately 10 km) configurations. Although view-angle artifacts in the MODIS AOT retrieval confound direct comparisons between averages derived from different sub-samples, careful analysis shows that with many portions of the Earth essentially unobserved, spatial sampling introduces uncertainty in the derived seasonal-regional mean AOT. These AOT spatial sampling artifacts comprise up to 60%of the full-swath AOT value under moderate aerosol loading, and can be as large as 0.1 in some regions under high aerosol loading. Compared to full-swath observations, narrower swath and single pixel width sampling exhibits a reduced ability to detect AOT trends with statistical significance. On the other hand, estimates of the global, annual mean AOT do not vary significantly from the full-swath values as spatial sampling is reduced. Aggregation of the MODIS data at coarse grid scales (10 deg) shows consistency in the aerosol trends across sampling strategies, with increased statistical confidence, but quantitative errors in the derived trends are found even for the full-swath data when compared to high spatial resolution (0.5 deg) aggregations. Using results of a model-derived aerosol reanalysis, we find consistency in our conclusions about a seasonal-regional spatial sampling artifact in AOT Furthermore, the model shows that reduced spatial sampling can amount to uncertainty in computed shortwave top-ofatmosphere aerosol radiative forcing of 2-3 W m(sup−2). These artifacts are lower bounds, as possibly other unconsidered sampling strategies would perform less well. These results suggest that future aerosol satellite missions having significantly less than full-swath viewing are unlikely to sample the true AOT distribution well enough to obtain the statistics needed to reduce uncertainty in aerosol direct forcing of climate.

remote sensing↗

Recent Improvements and Verification of A Full Body Model in Opensim

BACKGROUND: The dynamic feasibility [1,2] criterion, that the subject’s Center of Pressure (COP) be located within the Base of Support (BOS) which outlines the feet, has aided in assessing the stability of human motion recorded on earth while performing the recorded tasks in lunar gravity or as countermeasures exercises on a vibration isolation and stabilization system in microgravity. The convex hull of the BOS on the platform under the subject’s feet was estimated using virtual markers on the feet of the scaled subject model. The COP was calculated using the ground reaction forces and moments determined from motion capture data with biomechanical modeling tools [3]. Occasionally, large-amplitude oscillatory spikes or “artifacts” were observed in the subject’s linear and angular momentum derivatives, affecting some COP data derived from motion capture. The purpose of this investigation was to assess and improve the accuracy of model scaling and BOS estimation as well as to determine the efficacy of model adjustments in mitigating artifacts influencing motion capture-derived ground reaction force and COP results. METHODS: To aid evaluation of proposed process and model updates, motion capture data were collected for two subjects during unit test and range of motion trials, lunar tasks, and countermeasures exercise motions. Markers were added to the full body Plug-in Gait marker set [4] during data collection. New markers were placed on the front, back, sides, and top of the head to improve scaling using distances between marker pairs. Medial elbow markers were added to stabilize the upper arm during OpenSim Inverse Kinematics (IK) [5]. Finally, markers were added on the outer edge of the heels and on the outside edges of the first and last toes on each foot. These additional foot markers were made available to test new automated foot scaling techniques and to calculate the error between the subject’s estimated and recorded BOS. The modified unscaled OpenSim Full Body Rajagopal Model [6,7] was adjusted using some previously investigated techniques [8] to mitigate rapid shifts in joint angles occurring during IK, as these were found to cause the spike artifacts observed in subsequent stages of analysis. Since OpenSim models use Euler angles and rotation sequences, the arm axes of rotation were adjusted, and the pelvis order of rotation was changed to minimize the likelihood of encountering “gimbal lock” during common human motion. The model clavicle, arm, elbow, wrist, pelvis, and ankle angle limits were adjusted to better accommodate the full human range of motion seen in exercise and lunar data. The shoulder joint center was calculated using a “pivoting” algorithm [9], and both shoulder joint center and upper arm markers were included during IK to provide additional shoulder stability on a case-by-case basis. The quality of IK results was assessed by three criteria: minimizing error between recorded motion capture markers and model markers, checking for reasonable rates of change in joint angles between fames (i.e., no IK artifacts), and ensuring the absence of spikes in the inertial forces and angular momentum derivatives calculated using a custom OpenSim plugin [10]. RESULTS: The additional markers placed on the subject during data collection allowed the head and feet to be scaled more accurately using distances between new marker pairs. Scaling with BOS markers placed on the subject and removing the limit on subtalar angle resulted in more accurate BOS determination. Unrealistically large changes in joint angles between frames could be reduced by including clavicle, sternum, and medial elbow markers during IK. In cases with large arm ranges of motion, results could be further improved by running IK using medial elbow and virtual shoulder joint center markers. Model adjustments significantly improved the IK results affecting COP calculation and increased the accuracy of BOS estimation.

C A Bell↗

Neural network-based single material beam-hardening correction for X-ray CT in Additive Manufacturing

Beam-hardening (BH) artifacts are ubiquitous in X-ray CT scans of dense metal additively manufactured (AM) parts. While linearization approaches are useful for correcting beam-hardened data from single material objects, they either require a calibration scan or detailed system and material composition information. In this paper, we introduce a neural network-based, material-agnostic method to correct beam-hardening artifacts. We train a neural network to map the acquired beam-hardened projection values and the corresponding estimated thickness of the part based on an initial segmentation to beam-hardening related parameters, which can be used to compute the coefficients of a linearizing correction polynomial. A key strength of our approach is that, once the network is trained, it can be used for correcting beam hardening from a variety of materials without any calibration scans or detailed system and material composition information. Furthermore, our method is robust to errors in the estimated thickness due to the typical challenge of obtaining an accurate initial segmentation from reconstructions impacted by BH artifacts. We demonstrate the utility of our method to obtain high-quality CT reconstructions from a collection of AM parts -- suppressing cupping and streaking artifacts

Rahman, Obaid↗

Deterministic Simulation of First-Order Scattering in a Clinical X-ray Computed Tomography Scanner - Paper 81

In nondestructive testing (NDT) and medical diagnostic x-ray imaging (photon energy<140 keV), scattered x-ray caused by Compton and Rayleigh scattering should be eliminated. Scattered x-ray photons reduce image contrast, increase image noise, and introduce artifact into the reconstructed computed tomography (CT) images. In cone-beam CT, where the coverage of the x-ray beam and the area of the detector are significantly larger than those in fan-beam CT, x-ray photon scatter is one of the major sources of image degradation. The artifacts caused by scattered x-ray photon can be divided into two categories: 1) low spatial frequency scatter profile adds a positive bias to the detected radiation signal, thus reducing the effective attenuation of the imaged object, resulting in a negative bias in the measured linear attenuation coefficient in the image; 2) a high spatial frequency scatter profile causes a differential artifact, such as shading in uniform regions. A real x-ray scan is composed of both low and high frequency scatter profiles. Thus, the key to a successful scatter correction is the ability to accurately capture the scatter profile of a real x-ray imaging scan. The most accurate method for estimating a scatter profile is the Monte Carlo simulation. However, the computation cost of the Monte Carlo method makes it unfeasible for simulating real and complex scan geometries in clinical settings. A practical yet accurate scatter profile estimation method is through ray tracing techniques, where the scatter profiles are computed by tracking rays through the object's volume. The x-ray from the source is tracked when it interacts with the material in the volume. The interaction creates scattered x-rays, in all possible directions. These rays are again either attenuated or scattered, creating cascaded scatter events. In x-ray CT, the first-order scattering (where only one scatter interaction is encountered) accounts for the most severe image artifacts since this first-order scatter contains a high frequency component of the scatter profile. Previous studies have shown that ray tracing techniques are quite effective in simulating the contribution of first-order scattering in radiological images. In this study, a similar ray tracing technique is applied to simulate the scatter profile of a real x-ray computed tomography (CT) scan in clinical settings. A good agreement has been found between the simulated scatter profile and the experimental measurement result. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Quantifying Polymer Chain Orientation in Strong and Tough Nanofibers with Low Crystallinity: Toward Next Generation Nanostructured Superfibers

Advanced fibers revolutionized structural materials in the second half of the 20th century. However, all high-strength fibers developed to date are brittle. Recently, pioneering simultaneous ultrahigh strength and toughness were discovered in fine (<250 nm) individual electrospun polymer nanofibers (NFs). This highly desirable combination of properties was attributed to high macromolecular chain alignment coupled with low crystallinity. Quantitative analysis of the degree of preferred chain orientation will be crucial for control of NF mechanical properties. However, quantification of supramolecular nanoarchitecture in NFs with low crystallinity in the ultrafine diameter range is highly challenging. Here, we discuss the applicability of traditional as well as emerging methods for quantification of polymer chain orientation in nanoscale one-dimensional samples. Advantages and limitations of different techniques are critically evaluated on experimental examples. It is shown that straightforward application of some of the techniques to sub wavelength-diameter NFs can lead to severe quantitative and even qualitative artifacts. Sources of such size-related artifacts, stemming from instrumental, materials, and geometric phenomena at the nanoscale, are analyzed on the example of polarized Raman method but are relevant to other spectroscopic techniques. A proposed modified, artifact-free method is demonstrated. Outstanding issues and their proposed solutions are discussed. The results provide guidance for accurate nanofiber characterization to improve fundamental understanding and accelerate development of nanofibers and related nanostructured materials produced by electrospinning or other methods. Overall, we expect that the discussion in this review will also be useful to studies of many biological systems that exhibit nanofilamentary architectures and combinations of high strength and toughness.

36 MATERIALS SCIENCE↗

Life-cycle analysis of integrated biorefineries with co-production of biofuels and bio-based chemicals: co-product handling methods and implications: Co-product handling methods and implications of life-cycle analysis of biofuel and bio-chemical co-producing biorefineries

New integrated biorefinery (IBR) concepts are being investigated to co-produce hydrocarbon fuels and high-value bio-based chemicals to improve the economic viability of IBRs, to enhance biomass resource utilization efficiencies, and to maximize potential greenhouse gas (GHG) emission reductions. Unlike fuel-only biorefineries, IBRs may co-produce a significant amount of bio-based chemicals, whose emission implications for specific biorefinery products and the biorefinery as a whole need to be evaluated. We discuss this in principle and apply three sets of co-product handling methods to conduct life-cycle analysis (LCA) of modeled IBRs with co-production of two bioproduct examples - succinic acid and adipic acid - alongside a renewable diesel blendstock fuel product. The LCA results for the specific co-product handling methods that were examined shed light on potential artifacts of product-specific LCA with selected co-product methods. We discuss the advantages and limitations of each method and conclude that (i) a system-level or 'black-box' LCA allocation method is too simplistic to reflect appropriately the GHG burdens of distinctly different processing trains for fuels and chemicals in the IBR context, and (ii) the displacement method is the only co-product handling method that accounts fully for the emission effects of both the fuel product and the non-fuel bio-based co-products in the IBRs within the context of the existing fuel-focused GHG regulatory framework. Alternatively, biorefinery system-level LCA combines benefits of individual products to offer a complete picture. This system-level LCA approach offers a holistic LCA without somewhat arbitrary decisions either on an allocation basis or by the selection of an evaluation metric based on specific products.

09 BIOMASS FUELS↗

Physics‐based iterative reconstruction for dual‐source and flying focal spot computed tomography

Purpose For single‐source helical Computed Tomography (CT), both Filtered‐Back Projection (FBP) and statistical iterative reconstruction have been investigated. However, for dual‐source CT with flying focal spot (DS‐FFS CT), a statistical iterative reconstruction that accurately models the scanner geometry and acquisition physics remains unknown to researchers. Therefore, our purpose is to present a novel physics‐based iterative reconstruction method for DS‐FFS CT and assess its image quality. Methods Our algorithm uses precise physics models to reconstruct from the native cone‐beam geometry and interleaved dual‐source helical trajectory of a DS‐FFS CT. To do so, we construct a noise physics model to represent data acquisition noise and a prior image model to represent image noise and texture. In addition, we design forward system models to compute the locations of deflected focal spots, the dimension, and sensitivity of voxels and detector units, as well as the length of intersection between x‐rays and voxels. The forward system models further represent the coordinated movement between the dual sources by computing their x‐ray coverage gaps and overlaps at an arbitrary helical pitch. With the above models, we reconstruct images by an advanced Consensus Equilibrium (CE) numerical method to compute the maximum a posteriori estimate to a joint optimization problem that simultaneously fits all models. Results We compared our reconstruction with Siemens ADMIRE, which is the clinical standard hybrid iterative reconstruction (IR) method for DS‐FFS CT, in terms of spatial resolution, noise profile, and image artifacts through both phantoms and clinical scan datasets. Experiments show that our reconstruction has a higher spatial resolution, with a Task‐Based Modulation Transfer Function (MTF task ) consistently higher than the clinical standard hybrid IR. In addition, our reconstruction shows a reduced magnitude of image undersampling artifacts than the clinical standard. Conclusions By modeling a precise geometry and avoiding data rebinning or interpolation, our physics‐based reconstruction achieves a higher spatial resolution and fewer image artifacts with smaller magnitude than the clinical standard hybrid IR.

Wang, Xiao↗

Automated Programmable Logic Controller Memory Forensics Using RGB Image Analysis and Deep Learning

The introduction of Industry 4.0 and Internet-based technologies has enhanced industrial control system operations but have inadvertently increased their vulnerabilities to cyber attacks. When an industrial control system is compromised, security analysts need to identify the root cause quickly to start the recovery process and develop mitigation strategies. Memory forensics is critical in the incident analysis process to ascertain what occurred. Approaches for analyzing the persistent memory in industrial control devices are limited and almost nonexistent for volatile memory. This chapter proposes an automated methodology for programmable logic controller memory dump analysis using computer vision and deep learning techniques. The methodology converts the sequences of bytes in a programmable logic controller memory dump to red-green-blue pixels and employs a deep learning model that learns the underlying patterns and features of pre-labeled forensic artifacts in images and segments them into distinct regions. The trained model is employed to automatically segment new memory images and identify forensic artifacts. Evaluation of the methodology on a Schneider Electric Modicon M221 programmable logic controller under code injection and code modification attacks demonstrates its ability to detect attack artifacts in memory dumps.

Asmar Awad, Rima [ORNL] (ORCID:0000000233407742)↗

Conical ultrashort echo time (UTE) MRI in the evaluation of pediatric acute appendicitis

Purpose: Magnetic resonance imaging (MRI) sequences with conical k-space trajectories are able to decrease motion artifacts while achieving ultrashort echo times (UTE). We assessed the performance of free-breathing conical UTE MRI in the evaluation of the pediatric pelvis for suspected appendicitis. Methods: Our retrospective review of 84 pediatric patients who underwent MRI for suspected appendicitis compared three contrast-enhanced sequences: free-breathing conical UTE, breath-hold three-dimensional (3D) spoiled gradient echo (BH-SPGR), and free-breathing high-resolution 3D SPGR (FB-SPGR). Two radiologists performed blinded and independent evaluations of each sequence for image quality (four point scale), anatomic delineation (four point scale), and diagnostic confidence (five point scale). Subsequently, the three sequences were directly compared for overall image quality (− 3 to + 3 scale). Scores were compared using Kruskal–Wallis and Wilcoxon signed-rank tests. Results: UTE demonstrated significantly better perceived signal-to-noise ratio (SNR) and fewer artifacts than BH-SPGR and FB-SPGR (means of 3.6 and 3.4, 3.4 and 3.2, 3.1 and 2.7, respectively; p < 0.0006). BH-SPGR and FB-SPGR demonstrated significantly better contrast than UTE (means of 3.6, 3.4, and 3.2, respectively; p < 0.03). In the remaining categories, UTE performed significantly better than FB-SPGR (p < 0.00001), while there was no statistical difference between UTE and BH-SPGR. Direct paired comparisons of overall image quality demonstrated the readers significantly preferred UTE over both BH-SPGR (mean + 0.5, p < 0.00001) and FB-SPGR (mean + 1.2, p < 0.00001). Conclusions: In the evaluation of suspected appendicitis, free-breathing conical UTE MRI performed better in the assessed metrics than FB-SPGR. When compared to BH-SPGR, UTE demonstrated superior perceived SNR and fewer artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid kVp switching dual-energy CT in the assessment of urolithiasis in patients with large body habitus: preliminary observations on image quality and stone characterization

Purpose: The purpose of this study was to investigate the image quality (IQ) considerations of rapid kVp switching dual-energy CT (rsDECT) in the assessment of urolithiasis in patients with large body habitus and to evaluate whether it allows stone characterization. Materials and methods: In this IRB-approved, HIPAA compliant retrospective study, 93 consecutive patients (M/F = 72/21, mean age 56.9 years, range 23–83 years) with large body habitus (> 90 kg/198 lbs) who underwent dual-energy (DE) stone protocol CT on a rapid kVp switching DECT scanner between January 2013 and December 2016 were included. Scan acquisition protocol included an initial unenhanced single-energy CT (SECT) scan of KUB followed by targeted DECT in the region of stones. Two readers evaluated both CT data sets (axial 5 mm 120 kVp/140 kVp QC/70 keV monoenergetic, material density water/iodine images and coronal/sagittal 3 mm images) for the assessment of image quality (Scores: 1–4) and characterization of stone composition (reference standard: crystallography). Results: One hundred and five CT examinations were performed in 93 patients (mean body weight 105.12 ± 13.53 kg, range 91–154 kg), and a total of 321 urinary tract calculi (mean size-4.8 ± 3.2 mm, range 1.2–22 mm) were detected. Both SECT and targeted monoenergetic images were of acceptable image quality (mean IQ: 3.77 and 3.83, kappa 0.79 and 0.87 respectively). Material density water and iodine images had lower IQ scores (mean IQ: 2.97 and 3.09 respectively) with image quality deterioration due to severe photon starvation/streak artifacts in 20% (21/105) and 17% (18/105) scans, respectively. Characterization of stone composition into uric acid/non-uric acid stones was achieved in 93.14% (299/321) of calculi (mean size: 4.99 ± 3.3 mm, range 1.2–22 mm), while 7% (22/321) stones could not be characterized (mean size 3.03 ± 1.16 mm, range 1.6–6.4 mm) (p < 0.001). Most common reason for non-characterization was image quality deterioration of the material density iodine images due to severe photon starvation artifacts. On multivariate regression, stone size and patient weight were predictors of stone composition determination on DECT (p < 0.05). The transverse diameter had a weak negative correlation with stone composition determination, but it was not statistically significant. Stone characterization into uric acid vs. non-uric acid stones was accurate in 95% (n = 38/40) of stones in comparison with crystallography. Conclusion: In patients with large body habitus, rsDECT allowed characterization of most calculi (93%) despite image quality deterioration due to photon starvation/streak artifacts in up to 20% of material density images. Stone size and patient weight were predictors of stone composition determination on DECT, and small calculi in very large patients may not be characterized.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MDCT Versus MRI Assessment of Tumor Response After Transarterial Chemoembolization for the Treatment of Hepatocellular Carcinoma

The purpose of this study was to compare the ability of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) to evaluate treatment results after transarterial chemoembolization (TACE), with a special focus on the influence of Lipiodol on calculation of tumor necrosis according to EASL criteria. A total of 115 nodules in 20 patients (17 males, 3 females; 69.5 {+-} 9.35 years) with biopsy-proven hepatocellular carcinoma were treated with TACE. Embolization was performed using a doxorubicin-Lipiodol emulsion (group I) or DC Beads loaded with doxorubicin (group II). Follow-up included triphasic contrast-enhanced 64-row MDCT (collimation, 0.625 mm; slice, 3 mm; contrast bolus, 120 ml iomeprol; delay by bolus trigger) and contrast-enhanced MRI (T1 native, T2 native; five dynamic contrast-enhanced phases; 0.1 mmol/kg body weight gadolinium-DTPA; slice thickness, 4 mm). Residual tumor and the extent of tumor necrosis were evaluated according to EASL. Contrast enhancement within tumor lesions was suspected to represent vital tumor. In the Lipiodol-based TACE protocol, MDCT underestimated residual viable tumor compared to MRI, due to Lipiodol artifacts (23.2% vs 47.7% after first, 11.9% vs 31.2% after second, and 11.4% vs 23.7% after third TACE; p = 0.0014, p < 0.001, and p < 0.001, respectively). In contrast to MDCT, MRI was completely free of any artifacts caused by Lipiodol. In the DC Bead-based Lipiodol-free TACE protocol, MRI and CT showed similar residual tumor and rating of treatment results (46.4% vs 41.2%, 31.9 vs 26.8%, and 26.0% vs 25.6%; n.s.). In conclusion, MRI is superior to MDCT for detection of viable tumor residuals after Lipiodol-based TACE. Since viable tumor tissue is superimposed by Lipiodol artifacts in MDCT, MRI is mandatory for reliable decision-making during follow-up after Lipiodol-based TACE protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combining Deep Learning and scatterControl for High-Throughput X-ray CT Based Non-Destructive Characterization of Large-Scale Casted Metallic Components

X-ray computed tomography (XCT) is essential for nondestructive evaluation and quality control of large-scale metal components. XCT imaging, however, faces significant challenges from metal artifacts, particularly those caused by Compton scattering, which degrade image quality and obscure critical details. Hardware-based solutions (e.g. scatterControl) offer advancements by intercepting scattered photons and reducing artifacts, but they can be time-consuming and require additional processing. Here, we propose modifying and leveraging a novel deep learning (DL) framework, Simurgh, to enhance and accelerate scatter correction in XCT. By combining scatterControl with DL-based artifact removal, we demonstrate significant reduction in scan time while producing high-quality reconstructions. Through extensive evaluation on industrial XCT data, we show that our methods reduce scan time by up to more than 10 x while preserving flaw detectability. Quantitative analysis across multiple segmentation techniques confirms that Simurgh-based reconstructions consistently outperform traditional Feldkamp-Davis-Kress, model-based iterative reconstruction, and commercial DL models in both pixel-level and task-specific evaluations, enabling scalable, high-throughput XCT workflows for characterization of large scale components in applications such as casting and metal additive manufacturing.

Complex metal parts↗