Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerator Applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Adaptive machine learning for time-varying systems: low dimensional latent space tuning

Machine learning (ML) tools such as encoder-decoder convolutional neural networks (CNN) can represent incredibly complex nonlinear functions which map between combinations of images and scalars. For example, CNNs can be used to map combinations of accelerator parameters and images which are 2D projections of the 6D phase space distributions of charged particle beams as they are transported between various particle accelerator locations. Despite their strengths, applying ML to time-varying systems, or systems with shifting distributions, is an open problem, especially for large systems for which collecting new data for re-training is impractical or interrupts operations. Particle accelerators are one example of large time-varying systems for which collecting detailed training data requires lengthy dedicated beam measurements which may no longer be available during regular operations. We present a novel method of adaptive ML for time-varying systems. Our approach is to map very high (N ≈ 100k) dimensional inputs (a combination of scalar parameters and images) into the low dimensional (N ≈ 2) latent space at the output of the encoder section of an encoder-decoder CNN. We then actively tune the low dimensional latent space-based representation of complex system dynamics by the addition of an adaptively tuned feedback vector directly before the decoder sections builds back up to our image-based high-dimensional phase space density representations. This method allows us to learn correlations within and to quickly tune the characteristics of incredibly large parameter space systems and to track their evolution in real time based on feedback without massive new data sets for re-training. We demonstrate that our method can accurately predict and track the phase space of charged particle beams at various locations in a particle accelerator by adaptively adjusting in real-time while the unknown input beam distribution of the accelerator is changing in shape, charge, and offset and while the RF system of the accelerator itself is also changing in an unpredictable way. For FACET-II we demonstrate that such an approach has the potential to use transverse deflecting cavity and energy spread spectrum beam measurements to accurately predict 2D projections of the 6D phase space of the electron beam at the plasma wakefield acceleration interaction point where such diagnostics are unavailable.

47 OTHER INSTRUMENTATION↗

An adaptive masking method for beam halo measurement by a digital micro mirror device

We report that in high intensity particle beams, irregularities in cathode emission, scattering effects, dark current and space charge forces can lead to a common phenomenon termed beam halo with associated emittance growth, beam loss and overall beam quality degradation. It is of fundamental interest and practical importance to precisely monitor such beam halo, which could offer valuable insights into the experimental strategy for the suppression of this undesired feature. A Digital Micro mirror Device (DMD) is a computer-controlled micro-electrical-mechanical system that contains a compact array of physically independent reflective mirrors. Using a standard DMD, we come up with an adaptive masking method for halo measurement, which demonstrates superior robustness and efficiency comparing to the conventional approaches as confirmed by simulation and experimental results. Our development includes an integrated package of hardware, software and a graphic user interface (GUI) that is robust and portable and can be applied as a beam halo diagnostic for electron guns or radiating charged particle beams in general.

43 PARTICLE ACCELERATORS↗

AI for Experimental Controls at Jefferson Lab

We report the AI for Experimental Controls project is developing an AI system to control and calibrate detector systems located at Jefferson Laboratory. Currently, calibrations are performed offline and require significant time and attention from experts. This work would reduce the amount of data and the amount of time spent calibrating in an offline setting. The first use case involves the Central Drift Chamber (CDC) located inside the GlueX spectrometer in Hall D. We use a combination of environmental and experimental data, such as atmospheric pressure, gas temperature, and the flux of incident particles as inputs to a sequential Neural Network (NN) to recommend a high voltage setting and the corresponding calibration constants in order to maintain consistent gain and optimal resolution throughout the experiment. Utilizing AI in this manner represents an initial shift from offline calibration towards near real time calibrations performed at Jefferson Laboratory.

47 OTHER INSTRUMENTATION↗

Ultra-fast transverse beam orbit control in LCLS copper linac. Part I

We report current and future experiments at LCLS require x-ray pulse trains of variable time separation on the nanosecond scale. For instance, the cavity-based XFEL (CBXFEL) will use up to 4 pulses separated by 218.5 ns, the X-ray Laser Oscillator (XLO) will use 15 to 25 ns spaced pulses, and the Matter under Extreme Conditions (MEC) experiments use pulse trains separated by 5 nanoseconds or less. In this paper, we demonstrate an ultra-fast e-beam trajectory control method based on transverse electro-magnetic (TEM) striplines and state-of-the-art power sources, to enhance LCLS operations in these regimes.

47 OTHER INSTRUMENTATION↗

The potential of a TeV-scale muon-ion collider

We propose the development of a novel muon-proton and muon-nucleus collider facility at the TeV scale that is capable of performing precision deep inelastic scattering measurements in new regimes and providing a rich program in nuclear and particle physics. Such a facility could seed, or leverage, the development of a muon-antimuon collider and make use of the existing hadron accelerator infrastructure when sited at a facility such as Brookhaven National Laboratory, Fermilab, or CERN. Here, we discuss the possible energy and luminosity design parameters for several collider configurations, and illustrate the science potential with several studies on deep inelastic scattering kinematics, Higgs and vector boson production, top quark production, and beyond Standard Model leptoquark production. Detector design considerations and a possible road map toward development are also given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Combining the synergistic control capabilities of modeling and experiments: Illustration of finding a minimum-time quantum objective

A common way to manipulate a quantum system, for example spins or artificial atoms, is to use properly tailored control pulses. In order to accomplish quantum information tasks before coherence is lost, it is crucial to implement the control in the shortest possible time. Here we report the near time-optimal preparation of a Bell state with fidelity higher than 99% in an NMR experiment, which is feasible by combining the synergistic capabilities of modeling and experiments operating in tandem. In this work, the pulses preparing the Bell state are found by experiments that are recursively assisted with a gradient-based optimization algorithm working with a model. Thus, we exploit the interplay between model-based numerical optimal design and experimental-based learning control. Utilizing the balanced synergism between the dual approaches, as dictated by the case specific capabilities of each approach, should have broad applications for accelerating the search for optimal quantum controls.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tomography of longitudinal phase space linearization for the generation of attosecond electron bunches

The generation of electron bunches on the attosecond timescale is important for a multitude of accelerator-based applications. Here, we report on a tomographic measurement of the (pre)linearized longitudinal phase space of a low charge 3 MeV electron bunch generated with the 1.6 cell Pegasus photoinjector for the generation of attosecond bunches. The nonlinear correlations in the longitudinal phase space induced by space charge at the photocathode, radiofrequency field curvature of the gun, and vacuum dispersion are compensated using a compact X-band linearizer. Then, the initial and compensated phase of the picosecond electron bunch is precisely reconstructed by neural network assisted tomographic reconstruction from momentum spectra at varying buncher linac phase. Finally, we combine the measured phase space shape with particle tracking simulations to show that electron bunches as short as 941 as develop downstream the beamline.

Beam control↗

Active Plasma Lensing for Relativistic Laser-Plasma-Accelerated Electron Beams

The compact, tunable, radially symmetric focusing of electrons is critical to laser-plasma accelerator (LPA) applications. Experiments are presented demonstrating the use of a discharge-capillary active plasma lens to focus 100-MeV-level LPA beams. The lens can provide tunable field gradients in excess of 3000 T/m, enabling cm-scale focal lengths for GeV-level beam energies and allowing LPA-based electron beams and light sources to maintain their compact footprint. For a range of lens strengths, excellent agreement with simulation was obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AutoReP: Automatic ReLU Replacement for Fast Private Network Inference

The proliferation of the Machine-Learning-As-A-Service (MLaaS) market has brought to light a number of clients’ data privacy and security concerns. One promising solution is private inference (PI) techniques using cryptographic primitives. These techniques often come with high computation and communication overhead associated with the non-linear operator such as ReLU. Several approaches have been developed in reducing the number of ReLU operations, however, they either require a heuristic threshold selection or introduce significant accuracy drop. This work presents AutoReP, a gradient-based framework for non-linear operators reduction that aims to mitigate these concerns from a systematic perspective. AutoReP automates the process of discrete selection of ReLU and polynomial functions on neurons to accelerate PI applications. We also introduce distribution-aware polynomial approximation (DaPa) to accurately approximate ReLUs under given distribution, preserving model expressivity. Our experimental results demonstrate significant accuracy improvements of 6.12% (94.31%, 12.9K ReLU budget, CIFAR-10), 8.39% (74.92%, 12.9K ReLU budget, CIFAR-100), and 9.45% (63.69%, 55K ReLU budget, Tiny-ImageNet) over current state-of-the-art methods, e.g., SNL. Morever, AutoReP is applied to EfficientNet-B2 on ImageNet dataset, and achieved 75.55% accuracy with 176.1 × ReLU budget reduction.

Peng, Hongwu↗

VOLTTRON™: An Agent Platform for Integrating Electric Vehicles and Smart Grid

The VOLTTRON™ platform provides a secure environment for the deployment of intelligent applications in the smart grid. VOLTTRON design is based on the needs of control applications running on small form factor devices, namely security and resource guarantees. Services such as resource discovery, secure agent mobility, and interacting with smart and legacy devices are provided by the platform to ease the development of control applications and accelerate their deployment. VOLTTRON platform has been demonstrated in several different domains that influenced and enhanced its capabilities. This paper will discuss the features of VOLTTRON and highlight its usage to coordinate electric vehicle charging with home energy usage

VOLTTRON, agents, ev↗

Design of a 26 GHZ wakefield power extractor.

High frequency, high output power, and high efficiency RF sources have compelling applications in accelerators for high energy physics. The 26 GHz RF power extractor proposed in this paper provides a practical approach for generating high power RF in this particular frequency range. The extractor is designed to couple out RF power generated from the high charge electron bunch train at the Argonne Wakefield Accelerator (AWA) facility traversing a dielectric loaded waveguide. Designs are presented including parameter optimization, electromagnetic modeling of structures and RF couplers, and analysis of beam dynamics.

36 MATERIALS SCIENCE↗

Towards Sustainable Post-Exascale Leadership Computing

As computing systems approach the limits of traditional silicon technology, the diminishing returns in performance per watt present a significant barrier to sustaining growth in HPC. From a large-scale scientific supercomputing facility point of view, we propose a multifaceted strategy toward specialized hardware and architectures that are optimized for energy efficiency in specific applications. We also emphasize the need for integrating energy-aware practices across all levels of HPC, from system design and software development to operational policies. We discuss strategic opportunities such as the adoption of application-specific accelerators, the development of energy-efficient algorithms, and the implementation of data-driven operational analytics. Our goal is to develop a comprehensive roadmap ensuring that future leadership systems at OLCF can meet scientific demands while operating within stringent energy budgets, thereby supporting sustainable computing growth.

Shin, Woong↗

Through the lens of bioenergy crops: advances, bottlenecks, and promises of plant engineering

Advances in engineering of bioenergy crops were driven over the past years by adapting technological breakthroughs and accelerating conventional applications but also exposed intriguing challenges. New tools revealed rich interconnectivity in the exponentially growing and dynamic 'big' omics data' of metabolomes, transcriptomes, and genomes at previously inaccessible magnitude (global, cross-species, meta-) and resolution (single cell). Insights enabled fresh hypotheses and stimulated disciplines such as functional genomics with discovery of broad regulatory networks and their determinants, that is, DNA parts, including promoters, regulatory elements, and transcription factors. Their rational design, assembly into increasingly complex blueprints, and installation into diverse chassis is an existing frontier that may benefit from emerging technologies to address bottlenecks. Interweaving nature-inspired to fully synthetic parts has already allowed building of fine-tuned regulatory circuits, or new-to-nature metabolic routes insulated from the biological context of the chassis species. Similarly, developments and the evolving need for unifying principles in plant transformation and species-agnostic technologies highlight future opportunities for engineering the next generation of bioenergy plants.

60 APPLIED LIFE SCIENCES↗

Second cancer incidence risk estimates using BEIR VII models for standard and complex external beam radiotherapy for early breast cancer

Purpose: To compare organ specific cancer incidence risks for standard and complex external beam radiotherapy (including cone beam CT verification) following breast conservation surgery for early breast cancer.Method: Doses from breast radiotherapy and kilovoltage cone beam CT (CBCT) exposures were obtained from thermoluminescent dosimeter measurements in an anthropomorphic phantom in which the positions of radiosensitive organs were delineated. Five treatment deliveries were investigated: (i) conventional tangential field whole breast radiotherapy (WBRT), (ii) noncoplanar conformal delivery applicable to accelerated partial beast irradiation (APBI), (iii) two-volume simultaneous integrated boost (SIB) treatment, (iv) forward planned three-volume SIB, and (v) inverse-planned three volume SIB. Conformal and intensity modulated radiotherapy methods were used to plan the complex treatments. Techniques spanned the range from simple methods appropriate for patient cohorts with a low cancer recurrence risk to complex plans relevant to cohorts with high recurrence risk. Delineated organs at risk included brain, salivary glands, thyroid, contralateral breast, left and right lung, esophagus, stomach, liver, colon, and bladder. Biological Effects of Ionizing Radiation (BEIR) VII cancer incidence models were applied to the measured mean organ doses to determine lifetime attributable risk (LAR) for ages at exposure from 35 to 80 yr according to radiotherapy techniques, and included dose from the CBCT imaging. Results: All LAR decreased with age at exposure and were lowest for brain, thyroid, liver, and bladder (<0.1%). There was little dependence of LAR on radiotherapy technique for these organs and for colon and stomach. LAR values for the lungs for the three SIB techniques were two to three times those from WBRT and APBI. Uncertainties in the LAR models outweigh any differences in lung LAR between the SIB methods. Constraints in the planning of the SIB methods ensured that contralateral breast doses and LAR were comparable to WBRT, despite their added complexity. The smaller irradiated volume of the ABPI plan contributed to a halving of LAR for contralateral breast compared with the other plan types. Daily image guided radiotherapy (IGRT) for a left breast protocol using kilovoltage CBCT contributed <10% to LAR for the majority of organs, and did not exceed 22% of total organ dose. Conclusions: Phantom measurements and calculations of LAR from the BEIR VII models predict that complex breast radiotherapy techniques do not increase the theoretical risk of second cancer incidence for organs distant from the treated breast, or the contralateral breast where appropriate plan constraints are applied. Complex SIB treatments are predicted to increase the risk of second cancer incidence in the lungs compared to standard whole breast radiotherapy; this is outweighed by the threefold reduction in 5 yr local recurrence risk for patients of high risk of recurrence, and young age, from the use of radiotherapy. APBI may have a favorable impact on risk of second cancer in the contralateral breast and lung for older patients at low risk of recurrence. Intensive use of IGRTincreased the estimated values of LAR but these are dominated by the effect of the dose from the radiotherapy, and any increase in LAR from IGRT is much lower than the models' uncertainties.

60 APPLIED LIFE SCIENCES↗

A complete software application for automatic registration of x-ray mammography and magnetic resonance images

Purpose: This work presents a complete and automatic software application to aid radiologists in breast cancer diagnosis. The application is a fully automated method that performs a complete registration of magnetic resonance (MR) images and x-ray (XR) images in both directions (from MR to XR and from XR to MR) and for both x-ray mammograms, craniocaudal (CC), and mediolateral oblique (MLO). This new approximation allows radiologists to mark points in the MR images and, without any manual intervention, it provides their corresponding points in both types of XR mammograms and vice versa. Methods: The application automatically segments magnetic resonance images and x-ray images using the C-Means method and the Otsu method, respectively. It compresses the magnetic resonance images in both directions, CC and MLO, using a biomechanical model of the breast that distinguishes the specific biomechanical behavior of each one of its three tissues (skin, fat, and glandular tissue) separately. It makes a projection of both compressions and registers them with the original XR images using affine transformations and nonrigid registration methods. Results: The application has been validated by two expert radiologists. This was carried out through a quantitative validation on 14 data sets in which the Euclidean distance between points marked by the radiologists and the corresponding points obtained by the application were measured. The results showed a mean error of 4.2 ± 1.9 mm for the MRI to CC registration, 4.8 ± 1.3 mm for the MRI to MLO registration, and 4.1 ± 1.3 mm for the CC and MLO to MRI registration. Conclusions: A complete software application that automatically registers XR and MR images of the breast has been implemented. The application permits radiologists to estimate the position of a lesion that is suspected of being a tumor in an imaging modality based on its position in another different modality with a clinically acceptable error. The results show that the application can accelerate the mammographic screening process for high risk populations or for dense breasts.

60 APPLIED LIFE SCIENCES↗