Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

A simple double-focusing electrostatic ion beam deflector

We have developed an electrostatic, double-focusing 90 deg. deflector for fast ion beams consisting of concentric cylindrical plates of differing heights. In contrast to standard cylindrical deflectors, our design allows for focusing of an incoming parallel beam not only in the plane of deflection but also in the orthogonal direction. The optical properties of our design resemble those of a spherical capacitor deflector while it is much easier and more cost effective to manufacture.

43 PARTICLE ACCELERATORS↗

Automated high pressure cell for pressure jump x-ray diffraction

A high pressure cell for small and wide-angle x-ray diffraction measurements of soft condensed matter samples has been developed, incorporating a fully automated pressure generating network. The system allows both static and pressure jump measurements in the range of 0.1-500 MPa. Pressure jumps can be performed as quickly as 5 ms, both with increasing and decreasing pressures. Pressure is generated by a motorized high pressure pump, and the system is controlled remotely via a graphical user interface to allow operation by a broad user base, many of whom may have little previous experience of high pressure technology. Samples are loaded through a dedicated port allowing the x-ray windows to remain in place throughout an experiment; this facilitates accurate subtraction of background scattering. The system has been designed specifically for use at beamline I22 at the Diamond Light Source, United Kingdom, and has been fully integrated with the I22 beamline control systems.

43 PARTICLE ACCELERATORS↗

Note: New design of a cryogenic linear radio frequency multipole trap

A new design of a cryogenic linear 22-pole ion trap has been constructed and tested. It is essentially a copper housing to which opposite inner walls two electrode sets are attached via sapphire insulators. These stainless steel electrodes are electroformed in one piece to guarantee good heat conduction. Connected to an external coil, they form an LC-circuit of about 19 MHz resonance frequency. This circuit is excited with a rf power supply made of a commercial digital synthesizer followed by a 10 W amplifier. Buffer gas-cooled H{sub 2}D{sup +} ions have been stored in this trap at a nominal trap temperature of 14 K. Spectroscopy of the ions confirmed that the kinetic (Doppler) temperature is in reasonable agreement with this value.

43 PARTICLE ACCELERATORS↗

Study on the Effect of Energy Parameter of Electron on the Percentage Depth Dose of Electron Beam Using Monte Carlo Method

In medical linear accelerator, the energy parameter of electron plays important role to produce electron beam. The percentage depth dose of electron beams takes account not only on the value of electron's energy, but also on the type of electron's energy. The aims of this work are to carry on the effect of energy parameter of electron on the percentage depth dose of electron beam. Monte Carlo method is chosen in this project, due to the superior of this method for simulating the random process such as the transport particle in matter. The DOSXYZnrc usercode was used to simulate the electron transport in water phantom. Two aspects of electron's energy parameter were investigated using Monte Carlo simulations. In the first aspect, electron energy's value was varied also its spectrum. In the second aspect, the geometry of electron's energy was taken account on. The parallel beam and the point source were chosen as the geometry of The measurements of percentage depth dose were conducted to compare with its simulation. The ionization chamber was used in these measurements. Presentation of the results of this work is given not only based on the shape of the percentage depth dose from the simulation and measurement, but also on the other aspect in its curve. The result of comparison between the simulation and its measurement shows that the shape of its curve depends on the energy value of electron and the type of its energy. The energy value of electron affected the depth maximum of dose.

07 ISOTOPE AND RADIATION SOURCES↗

Test Study for Generation of Short Pulsed Synchrotron Radiation by Kicker Magnet in SPring-8 Storage Ring

A shorter pulse of synchrotron radiation is desired to measure a fast dynamic process exploration with a better resolution by material structure physics users. Among many complex schemes proposed for this purpose, we tested a simple scheme which makes use of a head-tail oscillation of a circulating electron beam with a small beam emittance. We have developed a new kicker magnet system which generated a short pulsed horizontal field of about 4.19 mT in 1.4 {mu}s pulse width with 1 Hz repetition. With this new developed kicker magnet system, we observed a bunch profile which leaned impressively between head and tail position by a visible light streak camera. Then we succeeded in achieving the shorter X-ray pulse width than the original one after a vertical slit being sliced by {approx}6 times. The observed X-ray pulse width was 7.38{+-}2.35 ps in FWHM.

43 PARTICLE ACCELERATORS↗

The dedicated QEXAFS facility at the SLS: Performance and Scientific Opportunities

The SuperXAS beamline at the Swiss Light Source (SLS) features a permanently installed monochromator for quick scanning EXAFS (QEXAFS) spectroscopy in series with a conventional double crystal monochromator (DCM). All installed optical components like collimating and focussing mirrors can be used by both devices. The remote exchange of the monochromators is possible in less than five minutes while maintaining the beam geometry on the sample. The QEXAFS system allows fast absorption scans down to the millisecond range for the investigation of time dependent processes. Using a Si(111) channel cut crystal the energy range from 5-16 keV can be covered, with a Si(311) cut the range 9.5-30 keV. Usually a quick scanning interval of 0.1 deg. - 2 deg. in Bragg angle is selected, thus covering XANES, full EXAFS or multiple edge scans of e.g. all L-edges of a heavy element. Up to about 80 spectra per second can be collected, corresponding to a time resolution of 12.5 ms. The high intensity of the beamline even facilitates fluorescence measurements on dilute samples.

43 PARTICLE ACCELERATORS↗

Linear Polarization Measurements with a New Soft X-Ray Polarimeter and Ellipsometer at a Bending Magnet Beamline of a Compact Storage Ring

Linear polarization measurements were carried out using a newly developed soft x-ray polarimeter and ellipsometer (SXPE) for complete polarization analysis at a soft x-ray beamline (BL-11) of the SR Center, Ritsumeikan University, Japan. A Mo/Si multilayer mirror (period: 10.36 nm, ratio of Mo layer to period: 0.64, and 23 bilayers with topmost Si layer) was deposited on the surface of a commercial Si(111) substrate by an ion beam sputtering method. It was cut into two pieces which were then used as reflection-type polarizers. When the incident wavelength was scanned from 12.4 nm to 14.8 nm by a Monk-Gillieson type varied-line-spacing grating monochromator of the BL-11, the angles of incidence of both the Mo/Si multilayer polarizers in the SXPE were also varied from 37.5 deg. to 52.3 deg. The polarizances depended strongly on the wavelength, and the best performance of over 99% was obtained in the vicinity of 14 nm. Using these polarizers, we assessed that the degree of linear polarization of the BL-11 was almost constant at 85-88% in the measured wavelength range.

43 PARTICLE ACCELERATORS↗

Measurement of the Magnet Blocks for SSRF Insertion Devices

Two in-vacuum undulators IVU25s and one elliptically polarized undulator EPU100 have been developed for SSRF. Two IVU25s with the same hybrid design contain about 640 Sm{sub 2}Co{sub 17} magnet blocks and the dimension of blocks is 65 Wx25 Hx9 D. The EPU100 of the APPLE-II type contains about 690 NdFeB magnet blocks with the dimension of 35 Wx35 Hx25 D. This paper describes the magnetic measurements of these magnet blocks with the Helmholtz coil measurement system for IVU25 magnet blocks and the Hall probe measurement system for EPU100 magnet blocks. The measured maximum magnetic moment deviation and the maximum angle deviation are less than {+-}1.0% and 1.1 deg. respectively both for Sm{sub 2}Co{sub 17} blocks and NdFeB blocks and satisfy the specifications of undulators.

43 PARTICLE ACCELERATORS↗

Synchronized monochromator and insertion device energy scans at SLS

Synchronous monochromator and insertion device energy scans were implemented at the Surfaces/Interfaces:Microscopy (SIM) beamline in order to provide the users fast X-ray magnetic dichroism studies (XMCD). A simple software control scheme is proposed based on a fast monochromator run-time energy readback which quickly updates the insertion device requested energy during an on-the-fly X-ray absorption scan (XAS). In this scheme the Plain Grating Monochromator (PGM) motion control, being much slower compared with the insertion device (APPLE-II type undulator), acts as a 'master' controlling the undulator 'slave' energy position. This master-slave software implementation exploits EPICS distributed device control over computer network and allows for a quasi-synchronous motion control combined with data acquisition needed for the XAS or XMCD experiment.

43 PARTICLE ACCELERATORS↗

Design and Technical Aspects of a New in Vacuum Transfocator at ESRF Beamline ID11

A tunable X-Ray focusing apparatus based on compound refractive lenses (CRL), referred to as a transfocator, has been installed for monochromatic beam (IAT in air transfocator) two years ago in the second optics hutch at ID11 at the ESRF. By varying the number of lenses in the beam, the energy focused and the focal length can be varied continuously throughout a large range of energies and distances.Based the success of the IAT, an in-vacuum transfocator (IVT) has now been built and installed at ID11.The aim of this poster is to describe and show the mechanical and technical solutions used to design and manufacture this new IVT.The IVT was installed last January in the first optics hutch at ID11. The IVT consists of nine water cooled cartridges containing 1, 2, 4, 8, 16, 32 Be lenses, and 32 and 64 Al lenses, and a protective aperture of Oe 900 {mu}m. The mechanical design is based on a system of pneumatically actuated cartridges with an auto positioning on two stainless steel rods. The vacuum vessel has translations and rotations perpendicular to the beam direction in order to align the axis of the cartridges with the x-ray beam.

43 PARTICLE ACCELERATORS↗

Improvement in Stability of SPring-8 Standard X-Ray Monochromators with Water-Cooled Crystals

SPring-8 standard double-crystal monochromators containing water-cooled crystals were stabilized to a sufficient level to function as a part of optics components to supply stable microfocused x-ray beams, by determining causes of the instability and then removing them. The instability was caused by two factors--thermal deformation of fine stepper stages in the monochromator, which resulted in reduction in beam intensity with time, and vibrations of coolant supply units and vacuum pumps, which resulted in fluctuation in beam intensity. We remodeled the crystal holders to maintain the stage temperatures constant with water, attached x-ray and electron shields to the stages in order to prevent their warming up, introduced accumulators in the water circuits to absorb pressure pulsation, used polyurethane tubes to stabilize water flow, and placed rubber cushions under scroll vacuum pumps. As a result, the intensity reduction rate of the beam decreased from 26% to 1% per hour and the intensity fluctuation from 13% to 1%. The monochromators were also modified to prevent radiation damage to the crystals, materials used as a water seal, and motor cables.

43 PARTICLE ACCELERATORS↗

Calibration of a Gas Monitor Detector using a Cryogenic Radiometer for Measuring the Radiant Power of Extreme Ultraviolet Free Electron Laser at SPring-8

A gas monitor detector was calibrated to a cryogenic radiometer for measuring the radiant power of EUV-FEL (extreme ultraviolet free electron laser) at the wavelengths of 51 nm and 61 nm. The output signals of the gas monitor detector showed good linearity against the radiant power measured by the radiometer in the range from 6 {mu}W to 160 {mu}W. The calibration coefficients of the gas monitor detector are determined with the relative standard uncertainty of around 5 %.

43 PARTICLE ACCELERATORS↗

Development of an X-ray Pinhole Monitor at NSRRC

An X-ray pinhole monitor is designed to measure the size, emittance and energy spread of the electron beam at NSRRC. The profile of the electron beam in a synchrotron radiation source is commonly assessed with a pinhole monitor of a cheap and simple design. To increase the resolution of the measurement, one method is to use the X-ray regime. The beam passes through a pinhole and the low-energy photons are eliminated with a filter. The beam profile is imaged with a fluorescent screen. The pinhole dimension is optimized on minimizing the diffraction blurring and maximizing the geometric resolution. The X-ray pinhole monitor is simulated with a SRW program. We designed an X-ray pinhole monitor to have three sets of pinhole array, six sets of filters and three sets to screens to increase the information acquired about the characteristics of the X-ray pinhole monitor. The simulation and design are presented here.

43 PARTICLE ACCELERATORS↗

Use of a synchronization card for XMCD measurements at the XMaS Beamline

X-ray Magnetic Circular Dichroism (XMCD) spectra from a 5 {mu}m polycrystalline Gd foil were measured in transmission across the Gd L{sub 2,3} edges using the Multipurpose Unit for Synchronisation, Sequencing and Triggering (MUSST) card developed at the European Synchrotron Radiation Facility (ESRF). The circularly polarized x-rays were produced by a diamond phase-plate and their helicity was rapidly reversed through the use of a piezo driven device. The signal measured for each helicity was recorded by the MUSST card synchronized to the helicity reversal. The results are compared to those obtained using an analogue lock-in technique.

43 PARTICLE ACCELERATORS↗

The RIKEN Materials Science Beamline at SPring-8: Towards Visualization of Electrostatic Interaction

In order to visualize molecular interaction by the experimental electrostatic potential analysis we have optimized the optical parameters and developed the high-resolution Debye-Scherrer camera at the RIKEN materials science beamline, BL44B2 of SPring-8. For the purpose the camera was designed to be equipped with the hybrid X-ray detector system. One is the conventional detector, the imaging plate readout off-line to carry out high d(interplanar spacing)-resolution measurements and the other is the CCD detector, which can be operated in a camera at variable distances for high angle-resolution measurements. In addition we have been developing an in-situ properties measurement system to visualize the electrostatic interaction completely synchronized with material functions.

43 PARTICLE ACCELERATORS↗

Extremely High Resolution Single Crystal Diffractometory for Orbital Resolution using High Energy Synchrotron Radiation at SPring-8

The investigation of accurate structure at charge density level will not only understand the function mechanism of physical property but also lead to design new functional materials. We have successfully installed large cylindrical camera at the BL02B1/SPring-8. In conceptual design, the image plate (IP) was selected as the detector, because such IP will not only detect wide range in one shot but also yield reliable data. In commissioning, the performance of this camera demonstrated to be suitable for the direct observation of d-electron system.

43 PARTICLE ACCELERATORS↗

New micro-beam beamline at SPring-8, targeting at protein micro-crystallography

A new protein micro-crystallography beamline BL32XU at SPring-8 is under construction and scheduled to start operation in 2010. The beamline is designed to provide the stabilized and brilliant micro-beam to collect high-quality data from micro-crystals. The beamline consists of a hybrid in-vacuum undulator, a liquid-nitrogen cooled double crystal monochromator, and K-B focusing mirrors with large magnification factor. Development of data acquisition system and end station consists of high-precision diffractometer, high-efficiency area detector, sample auto-changer etc. are also in progress.

43 PARTICLE ACCELERATORS↗

Quantum-dot-array diffraction grating with single order diffraction property for soft x-ray region

A gold transmission grating is used routinely to disperse the x-ray spectrum at the Z soft x-ray facility to measure the spectrum and temporal history of the absolute soft x-ray power emitted from z-pinch and hohlraum radiation sources. A quantum-dot-array diffraction grating (QDADG) of 250 lines/mm for soft x-ray is designed and fabricated for the first time according to the principle of binary sinusoidal transmission grating. The diffraction efficiencies of the grating are measured in the 150-300 eV photon energy range on the Beamline 3W1B of Beijing Synchrotron Radiation Facility. This article describes the basic concept and calibration techniques and presents calibration results. It is shown that the 250 lines/mm QDADG can be used to disperse light without higher-order diffractions in soft x-ray range, and the diffraction efficiencies of this grating are nearly constant (about 25%), which is beneficial in the spectrum analysis.

43 PARTICLE ACCELERATORS↗