Search NASA⌕ Search

SEARCH · Search NASA

Results for “Algorithm Development and Nuclear Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

2D/3D registration algorithm for lung brachytherapy

Purpose: A 2D/3D registration algorithm is proposed for registering orthogonal x-ray images with a diagnostic CT volume for high dose rate (HDR) lung brachytherapy. Methods: The algorithm utilizes a rigid registration model based on a pixel/voxel intensity matching approach. To achieve accurate registration, a robust similarity measure combining normalized mutual information, image gradient, and intensity difference was developed. The algorithm was validated using a simple body and anthropomorphic phantoms. Transfer catheters were placed inside the phantoms to simulate the unique image features observed during treatment. The algorithm sensitivity to various degrees of initial misregistration and to the presence of foreign objects, such as ECG leads, was evaluated. Results: The mean registration error was 2.2 and 1.9 mm for the simple body and anthropomorphic phantoms, respectively. The error was comparable to the interoperator catheter digitization error of 1.6 mm. Preliminary analysis of data acquired from four patients indicated a mean registration error of 4.2 mm. Conclusions: Results obtained using the proposed algorithm are clinically acceptable especially considering the complications normally encountered when imaging during lung HDR brachytherapy.

60 APPLIED LIFE SCIENCES↗

Characterization of Fresh Nuclear Fuel using Time-Of-Flight Neutrons

Neutrons offer excellent characterization capabilities for nuclear fuels and can provide non-destructive insight on micro structure, chemistry and crystallographic phase. Measurements are possible at reactors or pulsed sources, but the inherent energy resolution implicit at pulsed sources offers unique opportunities. Recent advances in 2D neutron detection enabled new capabilities of material characterization using neutron imaging and tomography for nuclear materials. Moreover, time-of-flight (TOF) neutron measurements can enable isotope specific tomography by deriving isotope densities from transmission spectra exhibiting neutron resonances, which are recorded for each pixel. Tomographic algorithms allow 3D reconstructions of the spatial distribution of isotopes, density and features in typical fuel pellet samples. The ability to select radiographs for different energies allows characterizing samples which are opaque for thermal neutrons, such as enriched fuels or fuels containing plutonium, by selecting epi-thermal neutron energies and by knowledge of the total neutron cross sections of the constituents, isotopic enrichment levels can be determined. Nuclear cross sections are typically not calculated directly and databases such as the Evaluated Nuclear Data File (ENDF) database provide this information with cross sections determined by standardized experimental measurements, such as neutron transmission measurements for individual isotopes. Utilizing the information in the ENDF database, the 'inverse' problem can be solved by assuming cross section parameters to be known parameters and areal densities can be determined. This work presents recent advances at the Los Alamos Neutron Science Center (LANSCE) facility at Los Alamos National Laboratory (LANL), which provides the infrastructure to handle radioactive samples, in the development of fuel characterization with TOF neutrons. Examples include recent work on prototype accident tolerant nuclear fuels (ATF). The potential application of these techniques for nondestructive examination of irradiated fuel is under consideration. Non-destructive access to materials features for specimens embedded in containers, particularly for hazardous samples, such as a radioactive nuclear fuel, is indispensable to characterize and ultimately license new fuel forms. Energy-resolve neutron imaging is a new tool for this research field. The results reported here present a new imaging technique, setting a milestone in the capabilities of measuring non-destructively absolute quantities of physical properties. The enabling physics behind this new technique are nuclear resonances. We have demonstrated how absolute areal densities can be extracted from radiographs utilizing pulsed neutron sources. This technique provides information that is otherwise difficult and costly to obtain. In the case of nuclear fuels, the results from energy-dispersive neutron imaging may guide destructive examination of irradiated fuel. This summery does not describe recent analysis, which is ongoing. Particularly, the implementation of calibration standards has improved the determination of enrichment levels without additional calibration. The analysis of the samples was performed with full tomographic reconstructions for isotope specific data and presents a first approach in absolute isotope specific 3D reconstruction. This work was predominantly funded by and received substantial support from the Fuel Cycle R and D program at Los Alamos National Laboratory. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

First Estimation of Model Parameters for Neutrino-Induced Nucleon Knockout Using Simulation-Based Inference

To enable an accurate determination of oscillation parameters, accelerator-based neutrino experiments require detailed simulations of nuclear interaction physics in the GeV regime. While substantial effort from both theory and experiment is currently being invested to improve the fidelity of these simulations, their present deficiencies typically oblige experimental collaborations to resort to empirical tuning of simulation model parameters. As the precision requirements of the field continue to become more stringent, machine learning techniques may provide a powerful means of handling corresponding growth in the complexity of future neutrino interaction model tuning exercises. To study the suitability of simulation-based inference (SBI) for this physics application, in this paper we revisit a tuned configuration of the GENIE neutrino event generator that was originally developed by the MicroBooNE collaboration. Despite closely reproducing the adopted values of four physics parameters when confronted with the tuned cross-section predictions as input, we find that our trained SBI algorithm prefers modestly different values (within MicroBooNE's assigned uncertainties) and achieves slightly better goodness-of-fit when inference is run on the experimental data set originally used by MicroBooNE. We also find that our trained algorithm can create a fair approximation of an alternative neutrino scattering simulation, NuWro, that shares only a subset of its physics model parameters with GENIE.

Tame-Narvaez, Karla [Fermilab] (ORCID:000000022249↗

SU-E-I-93: Improved Imaging Quality for Multislice Helical CT Via Sparsity Regularized Iterative Image Reconstruction Method Based On Tensor Framelet

Purpose: Inspired by compressive sensing, sparsity regularized iterative reconstruction method has been extensively studied. However, its utility pertinent to multislice helical 4D CT for radiotherapy with respect to imaging quality, dose, and time has not been thoroughly addressed. As the beginning of such an investigation, this work carries out the initial comparison of reconstructed imaging quality between sparsity regularized iterative method and analytic method through static phantom studies using a state-of-art 128-channel multi-slice Siemens helical CT scanner. Methods: In our iterative method, tensor framelet (TF) is chosen as the regularization method for its superior performance from total variation regularization in terms of reduced piecewise-constant artifacts and improved imaging quality that has been demonstrated in our prior work. On the other hand, X-ray transforms and its adjoints are computed on-the-fly through GPU implementation using our previous developed fast parallel algorithms with O(1) complexity per computing thread. For comparison, both FDK (approximate analytic method) and Katsevich algorithm (exact analytic method) are used for multislice helical CT image reconstruction. Results: The phantom experimental data with different imaging doses were acquired using a state-of-art 128-channel multi-slice Siemens helical CT scanner. The reconstructed image quality was compared between TF-based iterative method, FDK and Katsevich algorithm with the quantitative analysis for characterizing signal-to-noise ratio, image contrast, and spatial resolution of high-contrast and low-contrast objects. Conclusion: The experimental results suggest that our tensor framelet regularized iterative reconstruction algorithm improves the helical CT imaging quality from FDK and Katsevich algorithm for static experimental phantom studies that have been performed.

60 APPLIED LIFE SCIENCES↗

High rate pulse processing algorithms for microcalorimeters

It has been demonstrated that microcalorimeter spectrometers based on superconducting transition-edge-sensor can readily achieve sub-100 eV energy resolution near 100 keV. However, the active volume of a single microcalorimeter has to be small to maintain good energy resolution, and pulse decay times are normally in the order of milliseconds due to slow thermal relaxation. Consequently, spectrometers are typically built with an array of microcalorimeters to increase detection efficiency and count rate. Large arrays, however, require as much pulse processing as possible to be performed at the front end of the readout electronics to avoid transferring large amounts of waveform data to a host computer for processing. In this paper, they present digital filtering algorithms for processing microcalorimeter pulses in real time at high count rates. The goal for these algorithms, which are being implemented in the readout electronics that they are also currently developing, is to achieve sufficiently good energy resolution for most applications while being (a) simple enough to be implemented in the readout electronics and (b) capable of processing overlapping pulses and thus achieving much higher output count rates than the rates that existing algorithms are currently achieving. Details of these algorithms are presented, and their performance was compared to that of the 'optimal filter' that is the dominant pulse processing algorithm in the cryogenic-detector community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method for system-independent material characterization from spectral X-ray CT

We propose a method for material characterization using Spectral X-ray Computed Tomography (SCT). Our SCT method takes advantage of recently-developed MultiX ME 100 photon counting detectors to simultaneously measure the energy dependence of a material's linear attenuation coefficient (LAC). Relative electron density (ρ e ) and effective atomic number (Z e ) are estimated directly from the energy-dependent LAC measurements. The method employs a spectral correction algorithm and automated selection and weighting of the energy bins for optimized performance. When examining materials with Z e ≤ 23, this method achieves accuracy comparable to traditional dual-energy CT, which is often realized through consecutive data acquisitions, and is compatible with any spectral detector. The method disregards data in photon starved energy channels improving the detection of highly attenuating materials, compared to techniques that use energy integrating detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NUCLEOSYNTHESIS AND EVOLUTION OF MASSIVE METAL-FREE STARS

The evolution and explosion of metal-free stars with masses 10-100 M{sub sun} are followed, and their nucleosynthetic yields, light curves, and remnant masses determined. Such stars would have been the first to form after the big bang and may have left a distinctive imprint on the composition of the early universe. When the supernova yields are integrated over a Salpeter initial mass function (IMF), the resulting elemental abundance pattern is qualitatively solar, but with marked deficiencies of odd-Z elements with 7 {<=} Z {<=} 13. Neglecting the contribution of the neutrino wind from the neutron stars that they form, no appreciable abundances are made for elements heavier than germanium. The computed pattern compares favorably with what has been observed in metal-deficient stars with [Z] {approx}< -3. The amount of ionizing radiation from this generation of stars is {approx}2.16 MeV per baryon (4.15 B per M{sub sun}; where 1 B = 1 Bethe = 10{sup 51} erg) for a Salpeter IMF, and may have played a role in reionizing the universe. Neglecting rotation, most of the stars end their lives as blue supergiants and form supernovae with distinctive light curves resembling SN 1987A, but some produce primary nitrogen due to dredge-up and become red supergiants. These make brighter supernovae like typical Type IIp's. For the lower mass supernovae considered, the distribution of remnant masses clusters around typical modern neutron star masses, but above 20-30 M{sub sun}, with the value depending on explosion energy, black holes are copiously formed by fallback, with a maximum hole mass of {approx}40 M{sub sun}. A novel automated fitting algorithm is developed for determining optimal combinations of explosion energy, mixing, and IMF in the large model database to agree with specified data sets. The model is applied to the low-metallicity sample of Cayrel et al. and the two ultra-iron-poor stars HE0107-5240 and HE1327-2326. Best agreement with these very low metallicity stars is achieved with very little mixing, and none of the metal-deficient data sets considered show the need for a high-energy explosion component. In contrast, explosion energies somewhat less than 1.2 B seem to be preferred in most cases.

79 ASTRONOMY AND ASTROPHYSICS↗

Symetrica Measurements at PNNL

Symetrica is a small company based in Southampton, England, that has developed an algorithm for processing gamma ray spectra obtained from a variety of scintillation detectors. Their analysis method applied to NaI(Tl), BGO, and LaBr spectra results in deconvoluted spectra with the “resolution” improved by about a factor of three to four. This method has also been applied by Symetrica to plastic scintillator with the result that full energy peaks are produced. If this method is valid and operationally viable, it could lead to a significantly improved plastic scintillator based radiation portal monitor system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-Time Simultaneous 3D Volumetric Imaging and Mapping of Gamma-ray and Neutron Sources

The invention combines radiation detection instrumentation, data processing algorithms, and visualization software to enable, for the first time ever, simultaneous, real-time imaging of both gamma ray and neutron sources (fast and slow). Radiation detectors sensitive to gamma rays and neutrons are integrated with readout electronics that allow discriminated particles to be incorporated into real-time 3D volumetric reconstructions as two separate data streams. Using the Scene Data Fusion (SDF) conceptual framework and contextual sensors from the Localization and Mapping Platform (LAMP) developed at LBNL, gamma-ray and neutron data are fused onto contextual information from the environment around the detection system. The invention is compatible with radiation detection media capable of detecting and discriminating between gamma rays and neutrons or the pairing of multiple detectors separately capable of detecting gamma rays and/or neutrons. It can be integrated into a compact, lightweight imaging platform for operation as a hand-carry device, on unmanned aerial systems, and with unmanned vehicles. The ability to measure neutron enables the detection and 3D localization of shielded nuclear materials such as Pu-239 which is not possible with means of gamma-ray detection and spectroscopy overcoming of major limitation in the detection of such materials to-date.

Cates, Joshua↗

Direct NeTS sampling of nuclear graphite $S(α, β, T)$ in Serpent

For advanced reactor applications, Neural Thermal Scattering (NeTS) modules were developed to predict the thermal scattering law (TSL or $S(α, β, T)$) of a nuclear graphite neutron moderator. NeTS are multi-layer, feedforward artificial neural networks, which act as universal function approximators designed for TSL datasets. In this case, a 4-layer neural network with 164 neurons per layer is trained using FLASSH evaluated data in PyTorch and serialized as a torchscript dictionary to predict $S(α, β, T)$ on-the-fly. Relative, absolute and maximum percent deviations of NeTS from File 7 data generated using the FLASSH code are on the order of 0.01%, 0.1% and 1%, respectively, with low inference latencies of 0.000172 s per $S(α, β, T)$ at a given temperature. Capturing the full dimensionality of possible inelastic neutron-lattice interactions, NeTS functionality is embedded in the Serpent Monte Carlo code, where $S(α, β, T)_{NeTS}$ sampling is conducted on-the-fly and compared to ACE look-up-tables for predicting TREAT criticality. k-eff differences between sampling algorithms of 6 pcm are observed and are within the order of Monte Carlo uncertainty. Compared to discrete and continuous-energy ACE files (30 MB and 131 MB per temperature), the NeTS format is on the order of 200–300 kB for a continuous-temperature, interpolation-free representation of $S(α, β, T)$ and cross sections. NeTS-in-Serpent runtimes comparable with ACE look-up tables are achieved by scaling NeTS for high performance computing architectures with hybrid OpenMP + MPI parallelization. This work validates a novel, self-contained reactor physics framework for predictive cross sections, and demonstrates a general methodology for embedding modern machine learning libraries within existing neutronic analysis frameworks.

Nuclear Criticality Safety Program (NCSP)↗

Development of Proton Computed Tomography for Applications in Proton Therapy

Determination of the Bragg peak position in proton therapy requires accurate knowledge of the electron density and ratio of effective atomic number and mass (Z/A) of the body tissues traversed. While the Z/A ratio is fairly constant for human tissues, the density of tissues varies significantly. One possibility to obtain accurate electron density information of tissues is to use protons of sufficient energy to penetrate the patient and measure their energy loss. From these transmission measurements, it is possible to reconstruct a three-dimensional map of electron densities using algebraic techniques. The interest in proton computed tomography (pCT) has considerably increased in recent years due to the more common use of proton accelerators for cancer treatment world-wide and a modern design concept based on current high-energy physics technology has been suggested. This contribution gives a status update on the pCT project carried out by the pCT Collaboration, a group of institutions sharing interest and expertise in the development of pCT. We will present updated imaging data obtained with a small pCT prototype developed in collaboration with the Santa Cruz Institute of Particle Physics and installed on the proton research beam line at Loma Linda University Medical Center. We will discuss hardware decisions regarding the next-generation pCT scanner, which will permit scanning of head-sized objects. Progress has also been made in the formulation of the most likely path of protons through an object and parallelizable iterative reconstruction algorithms that can be implemented on general-purpose commodity graphics processing units. Finally, we will present simulation studies for utilizing pCT technology for on-line proton dose verification and tumor imaging with positron emission tomography (PET)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Evaluation of Machine Learning Techniques for Isotope Identification Contextualized by Training and Testing Spectral Similarity

Precise gamma-ray spectral analysis is crucial in high-stakes applications, such as nuclear security. Research efforts toward implementing machine learning (ML) approaches for accurate analysis are limited by the resemblance of the training data to the testing scenarios. The underlying spectral shape of synthetic data may not perfectly reflect measured configurations, and measurement campaigns may be limited by resource constraints. Consequently, ML algorithms for isotope identification must maintain accurate classification performance under domain shifts between the training and testing data. To this end, four different classifiers (Ridge, Random Forest, Extreme Gradient Boosting, and Multilayer Perceptron) were trained on the same dataset and evaluated on twelve other datasets with varying standoff distances, shielding, and background configurations. A tailored statistical approach was introduced to quantify the similarity between the training and testing configurations, which was then related to the predictive performance. Wilcoxon signed-rank tests revealed that the OVR-wrapped XGB significantly outperformed the other algorithms, with confidence levels of 99.0% or above for the 133Ba, 60Co, 137Cs, and 152Eu sources. The findings from this work are significant as they outline techniques to promote the development of robust ML-based approaches for isotope identification.

domain adaptation↗

RAVEN User Manual

RAVEN is a generic software framework to perform parametric and probabilistic analysis based on the response of complex system codes. The initial development was aimed to provide dynamic risk analysis capabilities to the Thermo-Hydraulic code RELAP-7, currently under development at the Idaho National Laboratory (INL). Although the initial goal has been fully accomplished, RAVEN is now a multi-purpose probabilistic and uncertainty quantification platform, capable to agnostically communicate with any system code. This agnosticism includes providing Application Programming Interfaces (APIs). These APIs are used to allow RAVEN to interact with any code as long as all the parameters that need to be perturbed are accessible by inputs files or via python interfaces. RAVEN is capable of investigating the system response, and investigating the input space using Monte Carlo, Grid, or Latin Hyper Cube sampling schemes, but its strength is focused to- ward system feature discovery, such as limit surfaces, separating regions of the input space leading to system failure, using dynamic supervised learning techniques. The development of RAVEN has started in 2012, when, within the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, the need to provide a modern risk evaluation framework became stronger. RAVEN principal assignment is to provide the necessary software and algorithms in order to employ the concept developed by the Risk Informed Safety Margin Characterization (RISMC) program. RISMC is one of the pathways defined within the Light Water Reactor Sustainability (LWRS) program. In the RISMC approach, the goal is not just the individuation of the frequency of an event potentially leading to a system failure, but the closeness (or not) to key safety-related events. Hence, the approach is interested in identifying and increasing the safety margins related to those events. A safety margin is a numerical value quantifying the probability that a safety metric (e.g. for an important process such as peak pressure in a pipe) is exceeded under certain conditions. The initial development of RAVEN has been focused on providing dynamic risk assessment capability to RELAP-7, currently under development at the INL and, likely, future replacement of the RELAP5-3D code. Most the capabilities that have been implemented having RELAP-7 as principal focus are easily deployable for other system codes. For this reason, several side activates are currently ongoing for coupling RAVEN with soft- ware such as RELAP5-3D, etc. The aim of this document is the explanation of the input requirements, focalizing on the input structure.

97 MATHEMATICS AND COMPUTING↗

Accelerating the Inference of the Exa.TrkX Pipeline

Recently, graph neural networks (GNNs) have been successfully used for a variety of particle reconstruction problems in high energy physics, including particle tracking. The Exa.TrkX pipeline based on GNNs demonstrated promising performance in reconstructing particle tracks in dense environments. It includes five discrete steps: data encoding, graph building, edge filtering, GNN, and track labeling. All steps were written in Python and run on both GPUs and CPUs. In this work, we accelerate the Python implementation of the pipeline through customized and commercial GPU-enabled software libraries, and develop a C++ implementation for inferencing the pipeline. The implementation features an improved, CUDA-enabled fixed-radius nearest neighbor search for graph building and a weakly connected component graph algorithm for track labeling. GNNs and other trained deep learning models are converted to ONNX and inferenced via the ONNX Runtime C++ API. The complete C++ implementation of the pipeline allows integration with existing tracking software. We report the memory usage and average event latency tracking performance of our implementation applied to the TrackML benchmark dataset.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HDRMC, an accelerated Monte Carlo dose calculator for high dose rate brachytherapy with CT-compatible applicators

Purpose: To present a new accelerated Monte Carlo code for CT-based dose calculations in high dose rate (HDR) brachytherapy. The new code (HDRMC) accounts for both tissue and nontissue heterogeneities (applicator and contrast medium). Methods: HDRMC uses a fast ray-tracing technique and detailed physics algorithms to transport photons through a 3D mesh of voxels representing the patient anatomy with applicator and contrast medium included. A precalculated phase space file for the{sup 192}Ir source is used as source term. HDRM is calibrated to calculated absolute dose for real plans. A postprocessing technique is used to include the exact density and composition of nontissue heterogeneities in the 3D phantom. Dwell positions and angular orientations of the source are reconstructed using data from the treatment planning system (TPS). Structure contours are also imported from the TPS to recalculate dose-volume histograms. Results: HDRMC was first benchmarked against the MCNP5 code for a single source in homogenous water and for a loaded gynecologic applicator in water. The accuracy of the voxel-based applicator model used in HDRMC was also verified by comparing 3D dose distributions and dose-volume parameters obtained using 1-mm{sup 3} versus 2-mm{sup 3} phantom resolutions. HDRMC can calculate the 3D dose distribution for a typical HDR cervix case with 2-mm resolution in 5 min on a single CPU. Examples of heterogeneity effects for two clinical cases (cervix and esophagus) were demonstrated using HDRMC. The neglect of tissue heterogeneity for the esophageal case leads to the overestimate of CTV D90, CTV D100, and spinal cord maximum dose by 3.2%, 3.9%, and 3.6%, respectively. Conclusions: A fast Monte Carlo code for CT-based dose calculations which does not require a prebuilt applicator model is developed for those HDR brachytherapy treatments that use CT-compatible applicators. Tissue and nontissue heterogeneities should be taken into account in modern HDR brachytherapy planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

The CINDER'90 transmutation code package for use in accelerator applications in combination with MCNPX

CINDER'90, a nuclear inventory code originated at the Bettis Atomic Power Laboratory for reactor irradiation calculations and extended for use of in accelerator dr iven systems and high-energy applications at Los Alamos National Laboratory, has been released as a code package for distribution through the Radiation Safety Information Computational Center (RSICC). The code package and its updated data libraries come with several scripts that allow calculations of multi-cell problems in combination with the radiation transport code MCNPX. A script was developed that manages all the pre-processing steps extracting the necessary information from MCNPX output or from one input file, and that runs the CINDER’90 code for a requested list of MCNPX cells and for a requested time history. A second script was developed that extracts the decay photon sources from CINDER’90 output for a requested list of cells and for a requested irradiation or decay time step and builds source deck for subsequent MCNPX calculations. Since the package release, improvements to CINDER’90 are underway in algorithms, libraries, and interfaces to transport codes.

43 PARTICLE ACCELERATORS↗

Multiresolution spatiotemporal mechanical model of the heart as a prior to constrain the solution for 4D models of the heart

In several nuclear cardiac imaging applications (SPECT and PET), images are formed by reconstructing tomographic data using an iterative reconstruction algorithm with corrections for physical factors involved in the imaging detection process and with corrections for cardiac and respiratory motion. The physical factors are modeled as coefficients in the matrix of a system of linear equations and include attenuation, scatter, and spatially varying geometric response. The solution to the tomographic problem involves solving the inverse of this system matrix. This requires the design of an iterative reconstruction algorithm with a statistical model that best fits the data acquisition. The most appropriate model is based on a Poisson distribution. Using Bayes Theorem, an iterative reconstruction algorithm is designed to determine the maximum a posteriori estimate of the reconstructed image with constraints that maximizes the Bayesian likelihood function for the Poisson statistical model. The a priori distribution is formulated as the joint entropy (JE) to measure the similarity between the gated cardiac PET image and the cardiac MRI cine image modeled as a FE mechanical model. In conclusion, the developed algorithm shows the potential of using a FE mechanical model of the heart derived from a cardiac MRI cine scan to constrain solutions of gated cardiac PET images.

60 APPLIED LIFE SCIENCES↗

FY 2025 End of Year Report: Seismic Monitoring of Underground Vibration Sources using Distributed Acoustic Sensing (DAS) and Seismometers

This end-of-year report summarizes progress on using seismic monitoring to detect, associate, and locate anomalous vibration signals that may indicate potential containment breaches. The work focused on four key tasks: 1. Developing a database of continuous waveforms and ground-truth event data from multiple sensing modalities. 2. Refining and implementing detection and association algorithms to generate a catalog of anomalous underground activities. 3. Testing and improving distributed acoustic sensing amplitude-based geolocation methods to build an event location catalog. 4. Testing and refining seismic array polarization-based geolocation methods to build an event location catalog. This report provides a brief recap of results from the FY25 midyear report (Tasks 1 and 2) and presents new findings from geolocation methods (Tasks 3 and 4).

58 GEOSCIENCES↗