Search NASASearch

SEARCH · Search NASA

Results for “Batteries for Advanced Transportation Technologies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,501 records · Page 29

Synthetic battery cycling techniques

The group of techniques that as a class are referred to as synthetic battery cycling are described with reference to spacecraft battery systems. Synthetic battery cycling makes use of the capability of computer graphics to illustrate some of the basic characteristics of operation of individual electrodes within an operating electrochemical cell. It can also simulate the operation of an entire string of cells that are used as the energy storage subsystem of a power system.

Leibecki, H.

Pocket nickel cadmium cell and battery evaluation

The Nickel Cadmium 129-ampere hour cell was tested in order to characterize the cell under controlled conditions. Results of charge characterization and discharge characterization are reported. Ampere hour efficiency, open circuit stand, and cycle life operation results are included. The battery is briefly described.

Lear, J. W.

Sodium Sulfur Battery Cell Experiment (NaSBE)

The Ford Motor Company published papers describing new types of secondary battery comprised of: solid, sodium ion conducting electrolyte; liquid metal electrode; redox electrode; operating temperature between 300 and 400 deg. C; specific energy of 150 Wh/kg; and a nominal voltage of 2.0 V.

Garner, J. Christopher

Battery Systems for X-38 Crew Return Vehicle (CRV) and Deorbit Propulsion Stage (DPS)

A 28V 32 Ah cell Li/MnO2 and a 28V NiMH battery systems for the Deorbit Propulsion Stage (DPS) and the X-38 Crew Return Vehicle (CRV) are developed in Friwo-Silforkraft, Germany with the following objectives and approach: Provide safe battery designs for lowest volume and cost, and within schedule; Take advantage of less complex requests for V201 vs OPS CRV to simplify design and reduce cost; Use only existing commercial cell designs as building blocks for larger battery; Derive battery designs from the ASTRO-SPAS design which is the largest lithium battery design with Shuttle flight experience; Place maximum amount of battery energy on DPS; DPS battery is non rechargeable; and CRV batteries are rechargeable. This paper contains the following sections: a brief introduction on CRV requirements, CRV advantages over Soyuz, and X-38 programs; Battery objectives and approach; Battery requirements and groundrules (performance, on-orbit operation, etc); Design trades, solutions, redundancy plan, and margins; Envelope, size, and mass; Interfaces (structural, electrical & thermal); and Deviation from OPS CRV.

Darcy, Eric

Li-ion Battery Aging with Hybrid Physics-Informed Neural Networks and Fleet-wide Data

In this work, we propose a hybrid model for Li-ion battery discharge and aging prediction that leverages fleet-wide data to predict future capacity drops.The model is built upon an hybrid approach merging physics-based and empirical equations, as well as neural network models in a recurrent neural network cell. The hybrid physics-informed neural network can predict voltage discharge cycles given the loading profile, and estimate the used capacity of the battery under random-loading conditions by tracking aging parameters connected to the residual capacity of the battery. By merging information on the battery aging parameters with existing fleet-wide aging data, the model can predict the future residual capacity of the battery that is being monitored, and therefore enable predictions of voltage discharge curves far ahead in the battery life cycle. We validated the approach using the NASA Prognostics Data Repository Battery data-set, which contains experimental data on Li-ion batteries discharged at random loading conditions in a controlled environment. The approach also allows the identification of discrepancies between the battery aging trend and the trend observed at the fleet level, so that batteries behaving differently from the rest of the fleet can be subject to closer monitoring and further testing to refine predictions.

PINN

High voltage battery cell scanner development

Battery cell voltage scanners have been previously used in low voltage spacecraft applications. In connection with future missions involving an employment of high-power high voltage power subsystems and/or autonomous power subsystem management for unattended operation, it will be necessary to utilize battery cell voltage scanners to provide battery cell voltage information for early detection of impending battery cell degradation/failures. In preparation for such missions, a novel battery cell voltage scanner design has been developed. The novel design makes use of low voltage circuit modules which can be applied to high voltage batteries in a building block fashion. A description is presented of the design concept and test results of the high voltage battery cell scanner, and its operation with an autonomously managed power subsystem is discussed.

Lepisto, J. W.

Reserve Li/SOC12 Battery Safety Testing

A reserve Lithium/Thionyl Chloride Battery concept is developed and undergoing feasibility testing in terms of performance, safety and abusive conditions. The feasibility of employing a battery of this type to replace thermal batteries in certain applications is demonstrated. Excellent performance of a Li/SOCl2 reserve battery is obtained across the temperature range from 0 C to +44 C. Performance improvement over the thermal battery usage is greater by a factor of 3 when discharge time and energy density are compared. Performance over an expanded temperature range is also possible. Safety and abusive testing is accomplished successfully on a series of five units. Further performance improvements can be achieved with regard to battery weight and volume reductions.

Dils, C. T.

Battery Relevant Cell Side Wall Rupture Characterization

The propensity for a cell design to experience can side wall rupture (SWR) during thermal runaway is highly influenced by how a battery design mechanically constrains its cells. Testing cells while unsupported has been found to yield false negative results that don't represent this risk in a battery configuration. This talk addresses how to verify the adequacy of battery design measures used to control SWR and how to get results relevant, accurate, and statistically defendable for a proposed battery design.

thermal runaway

Battery Fault Detection with Saturating Transformers

A battery monitoring system utilizes a plurality of transformers interconnected with a battery having a plurality of battery cells. Windings of the transformers are driven with an excitation waveform whereupon signals are responsively detected, which indicate a health of the battery. In one embodiment, excitation windings and sense windings are separately provided for the plurality of transformers such that the excitation waveform is applied to the excitation windings and the signals are detected on the sense windings. In one embodiment, the number of sense windings and/or excitation windings is varied to permit location of underperforming battery cells utilizing a peak voltage detector.

Davies, Francis J.

Battery Cell Voltage Sensing and Balancing Using Addressable Transformers

A document discusses the use of saturating transformers in a matrix arrangement to address individual cells in a high voltage battery. This arrangement is able to monitor and charge individual cells while limiting the complexity of circuitry in the battery. The arrangement has inherent galvanic isolation, low cell leakage currents, and allows a single bad cell in a battery of several hundred cells to be easily spotted.

Davies, Francis

Development of new sealed bipolar lead-acid battery

New light weight composite bipolar plates which can withstand the corrosive environment of the lead acid battery have made possible the construction of a sealed bipolar lead acid battery that promises to achieve very high specific power levels and substantially higher energy densities than conventional lead acid batteries. Performance projections based on preliminary experimental results show that the peak specific power of the battery can be as high as 90 kW/kg, and that a specific power of 5 kW/kg can be sustained over several thousand pulses.

Attia, Alan I.

Full-charge indicator for battery chargers

A full-charge indicator for battery chargers, includes a transistor which is in a conductive state as long as charging current to the battery is not less than a level which indicates that the battery did not reach full charge. When the battery reaches full charge, a voltage drop in a resistor in the charging current path is not sufficient to maintain the transistor in a conducting state, and therefore it is switched off. When this occurs an LED is turned on, to indicate a full charge state of the battery. A photocoupler together with a photocoupler transistor are included. When the transistor is off, the photocoupler activates the photocoupler transistor to shunt out a resistor, thereby reducing the charging current to the battery to a float charging current and prevent the battery from being overcharged and damaged.

Cole, Steven W.

Satellite battery testing status

Because of the large numbers of satellite cells currently being tested and anticipated at the Naval Weapons Support Center (NAVWPNSUPPCEN) Crane, Indiana, satellite cell testing is being integrated into the Battery Test Automation Project (BTAP). The BTAP, designed to meet the growing needs for battery testing at the NAVWPNSUPPCEN Crane, will consist of several Automated Test Stations (ATSs) which monitor batteries under test. Each ATS will interface with an Automation Network Controller (ANC) which will collect test data for reduction.

Haag, R.

Management and Performance of APPLE Battery in High Temperature Environment

India's first experimental communication satellite, APPLE, carried a 12 AH Ni-Cd battery for supplying power during eclipse. Failure to deploy one of the two solar panels resulted in the battery operating in a high temperature environment, around 40 C. This also resulted in the battery being used in diurnal cycles rather than just half yearly eclipse seasons. The management and performance of the battery during its life of two years are described. An attempt to identify the probable degradation mechanisms is also made.

Suresh, M. S.

Optimal Battery Charging for Damage Mitigation

Our control philosophy is to charge the NiH2 cell in such a way that the damage incurred during the charging period is minimized, thus extending its cycle life. This requires nonlinear dynamic model of NiH2 cell and a damage rate model. We must do this first. This control philosophy is generally considered damage mitigating control or life-extending control. This presentation covers how NiH2 cells function, electrode behavior, an essentialized model, damage mechanisms for NiH2 batteries, battery continuum damage modeling, and battery life models. The presentation includes graphs and a chart illustrating how charging a NiH2 battery with different voltages and currents affects damages the battery and affects its life. The presentation concludes with diagrams of control system architectures for tracking battery recharging.

Hartley, Tom T.

Chemically rechargeable battery

Batteries (50) containing oxidized, discharged metal electrodes such as an iron-air battery are charged by removing and storing electrolyte in a reservoir (98), pumping fluid reductant such as formalin (aqueous formaldehyde) from a storage tank (106) into the battery in contact with the surfaces of the electrodes. After sufficient iron hydroxide has been reduced to iron, the spent reductant is drained, the electrodes rinsed with water from rinse tank (102) and then the electrolyte in the reservoir (106) is returned to the battery. The battery can be slowly electrically charged when in overnight storage but can be quickly charged in about 10 minutes by the chemical procedure of the invention.

Graf, James E.

Thermal Analysis on Large Format Lithium-Ion Batteries in Thermal Runaway

Lithium-ion (Li-ion) batteries can deliver electrical power across a large range of applications, and large format versions of these batteries are common in aerospace for their low mass and energy dense properties. Li-ion cells usage has increased as they are more power dense than fuel cells and have overall higher performance over lead-acid/NiCd batteries. However, Li-ion cells can experience Thermal Runaway (TR) via electro-chemical, mechanical, or thermal abuse. TR is a phenomenon where the stored energy in a cell is rapidly released along with vented gases and other effluents. A cell is generally determined to be in TR if its internal heat generation has surpassed its ability to dissipate that heat. If a Li-ion cell enters TR, propagation within the battery may occur. Propagation is the chain reaction that can occur to nearby cells due to a cell that has entered TR initially. Understanding a battery’s susceptiveness to propagation is necessary to evaluate risks associated with TR phenomenon. To determine if a battery is designed in a sufficient manner to prevent battery propagation if single cell TR occurs, testing and thermal analysis of the battery must be conducted. The presentation for TFAWS 2026 will cover considerations for battery TR thermal analysis, such as: testing methods, influences on the cells, failure mechanisms, and TR parameters. This presentation will include a walkthrough of an example battery TR thermal analysis, and the results thereof.

Lithium Ion Batteries

Battery performance of the SKYNET 4A spacecraft during the first six years of on station operation

The SKYNET 4A spacecraft is a three-axis stabilized geostationary earth-orbiting military communications satellite which was launched on 1 Jan. 1990 aboard a Titan 3 launch vehicle. The power subsystem is a twin bus, twin battery semi-regulated system and is equipped with one 28-cell, 35 Ampere-hour battery per bus. The cells were manufactured by Gates Aerospace Batteries of Gainesville, FL, and the batteries were built, tested and integrated by British Aerospace Space Systems Ltd. This paper presents a brief survey of the first six years of on-station operation and the operational battery management strategy that has been adopted. Thermal management constraints have led to an unconventional battery operational regime. However, no sign of degradation is evident and the observed spacecraft battery performance remains nominal.

Johnson, P. J.