Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Prompt and delayed spectroscopy of {sup 142}Tb using recoil-isomer tagging

Recoil-isomer tagging has been used to characterize the states built upon an I{sup {pi}}=8{sup +} isomer in {sup 142}Tb. High-spin states of the neutron-deficient nucleus {sup 142}Tb were populated using an {sup 54}Fe beam, accelerated onto a {sup 92}Mo target of thickness {approx}500 {mu}g/cm{sup 2} at energies of 245, 252, and 265 MeV using the K130 cyclotron at the University of Jyvaeskylae, Finland. Use of the JUROGAM target-position Ge-detector array coupled with the GREAT focal-plane spectrometer at the RITU gas-filled recoil separator has significantly increased the efficiency of the isomer-tagging technique. The rotational band built upon the I{sup {pi}}=8{sup +} isomeric state was established with isomer-tagged {gamma}-{gamma} coincidence data and angular distributions were measured for some of the more intensely populated states. Two previously unobserved bands that bypass the isomer were also established. The new data have been interpreted within the framework of the cranked-shell model. The data show good agreement with the calculated triaxial nuclear shape with {gamma}=-30 deg. for the {sup 142m2}Tb isomeric state. The B(M1)/B(E2) branching ratios, nuclear alignment, signature splitting, and reduced transition probability, B(E1), of the isomeric state have been systematically compared with those of the neighboring nuclei. These comparisons give further evidence for the {pi}h{sub 11/2} x {nu}h{sub 11/2} configuration of the isomer.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-C-BRC-04: Efficient Dose Calculation Algorithm for FFF IMRT with a Simplified Bivariate Gaussian Source Model

Purpose: To develop an efficient and accurate independent dose calculation algorithm with a simplified analytical source model for the quality assurance and safe delivery of Flattening Filter Free (FFF)-IMRT on an Elekta Versa HD. Methods: The source model consisted of a point source and a 2D bivariate Gaussian source, respectively modeling the primary photons and the combined effect of head scatter, monitor chamber backscatter and collimator exchange effect. The in-air fluence was firstly calculated by back-projecting the edges of beam defining devices onto the source plane and integrating the visible source distribution. The effect of the rounded MLC leaf end, tongue-and-groove and interleaf transmission was taken into account in the back-projection. The in-air fluence was then modified with a fourth degree polynomial modeling the cone-shaped dose distribution of FFF beams. Planar dose distribution was obtained by convolving the in-air fluence with a dose deposition kernel (DDK) consisting of the sum of three 2D Gaussian functions. The parameters of the source model and the DDK were commissioned using measured in-air output factors (Sc) and cross beam profiles, respectively. A novel method was used to eliminate the volume averaging effect of ion chambers in determining the DDK. Planar dose distributions of five head-and-neck FFF-IMRT plans were calculated and compared against measurements performed with a 2D diode array (MapCHECK™) to validate the accuracy of the algorithm. Results: The proposed source model predicted Sc for both 6MV and 10MV with an accuracy better than 0.1%. With a stringent gamma criterion (2%/2mm/local difference), the passing rate of the FFF-IMRT dose calculation was 97.2±2.6%. Conclusion: The removal of the flattening filter represents a simplification of the head structure which allows the use of a simpler source model for very accurate dose calculation. The proposed algorithm offers an effective way to ensure the safe delivery of FFF-IMRT.

60 APPLIED LIFE SCIENCES↗

Scaling of p{sub T} distributions for p and p produced in Au+Au collisions at {radical}(s{sub NN})=200 GeV

With the experimental data from STAR and PHENIX on the centrality dependence of the p{sub T} spectra of protons and antiprotons produced at midrapidity in Au+Au collisions at 200 GeV, we show that for protons and antiprotons there exists a scaling distribution independent of the colliding centrality. The scaling functions can also describe data from BRAHMS for both proton and antiproton spectra at y=2.2 and 3.2. The scaling behaviors are shown to be incompatible with the usual string fragmentation scenario for particle production.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Full-Automatic XAFS Measurement System of the Engineering Science Research II beamline BL14B2 at SPring-8

The Engineering Science Research II beamline BL14B2 at SPring-8 is a hard X-ray bending magnet beamline covering the wide energy range from 3.8 to 72 keV, and has been open to XAFS users since September 2007. The gas distribution and exhaust gas treatment systems have been installed for the in-situ XAFS measurements. Recent improvements in the speed of XAFS measurements have increased the demand for automated measurements. We have developed such a system, in which the adjustment of X-ray optics and the XAFS measurement in transmission mode can be performed automatically.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Helicon thruster plasma modeling: Two-dimensional fluid-dynamics and propulsive performances

An axisymmetric macroscopic model of the magnetized plasma flow inside the helicon thruster chamber is derived, assuming that the power absorbed from the helicon antenna emission is known. Ionization, confinement, subsonic flows, and production efficiency are discussed in terms of design and operation parameters. Analytical solutions and simple scaling laws for ideal plasma conditions are obtained. The chamber model is then matched with a model of the external magnetic nozzle in order to characterize the whole plasma flow and assess thruster performances. Thermal, electric, and magnetic contributions to thrust are evaluated. The energy balance provides the power conversion between ions and electrons in chamber and nozzle, and the power distribution among beam power, ionization losses, and wall losses. Thruster efficiency is assessed, and the main causes of inefficiency are identified. The thermodynamic behavior of the collisionless electron population in the nozzle is acknowledged to be poorly known and crucial for a complete plasma expansion and good thrust efficiency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Eye-Safe KGd(WO{sub 4}){sub 2} Raman Lasers: Comparative Study of Pumping of Nd:KGd(WO{sub 4}){sub 2} Lasers With {sup 4}F{sub 3/2} → {sup 4}I{sub 11/2} and {sup 4}F{sub 3/2} → {sup 4}I{sub 13/2} Working Transitions{sup **}

This is a comparative study of eye-safe extracavity KGd(WO{sub 4}){sub 2} (KGW) Raman lasers that convert multimode emission from pulsed Nd:KGW lasers operating on the {sup 4}F{sub 3/2} → {sup 4}I{sub 11/2} and {sup 4}F{sub 3/2} → {sup 4}I{sub 13/2} transitions into the third Stokes component at λ = 1500 nm and the first Stokes component at λ = 1507 or 1538 nm. For equal sizes of the Raman and laser sections of a Raman laser emitting the third Stokes component, the pulse energy is higher (~14.2 mJ) and the divergence of the Stokes beam is lower (~9.4 mrad) for a lower energy of the Nd:KGW laser (~6.7 J). For pump pulse energies of 29–34 mJ, all the Raman lasers have essentially the same optical lasing efficiency of up to 36%. In terms of the electrical energy delivered to the flashlamp, however, the overall efficiency of the Raman laser for the third Stokes component is a factor of ~1.7 higher. The duration of the Raman pulses is comparable to that of the pump pulses and is ~20 ns for the first Stokes components. The pulse in the third Stokes component is shorter by a factor of 2.5–3. Given the different pump levels and the differences in the thermallyinduced optical distortions of the Nd:KGW laser components, the energy density distribution for beams of the first Stokes components is elliptical, while that of the third Stokes components is almost circular. The possibility of simultaneous lasing at wavelengths of 1507 and 1538 nm with parallel and mutually orthogonal polarizations of the Stokes waves is demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A heterodyne interferometer for angle metrology

We have developed a compact, high-resolution, angle measurement instrument based on a heterodyne interferometer. Common-path heterodyne interferometer metrology is used to measure displacements of a reflective target surface. In the interferometer set up, an optical mask is used to sample the laser beam reflecting back from four areas on a target surface. From the relative displacement measurements of the target surface areas, we can simultaneously determine angular rotations around two orthogonal axes in a plane perpendicular to the measurement beam propagation direction. The device is used in a testbed for a tracking telescope system where pitch and yaw angle measurements of a flat mirror are performed. Angle noise measurement of the device shows 0.1 nrad/{radical}(Hz) at 1 Hz, at a working distance of 1 m. The operation range and nonlinearity of the device when used with a flat mirror is approximately {+-}0.15 mrad, and 3 {mu}rad rms, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design Studies for a VUV--Soft X-ray Free-Electron Laser Array

Several recent reports have identified the scientific requirements for a future soft X-ray light source [1, 2, 3, 4, 5], and a high-repetition-rate free-electron laser (FEL) facility responsive to them is being studied at Lawrence Berkeley National Laboratory (LBNL) [6]. The facility is based on a continuous-wave (CW) superconducting linear accelerator with beam supplied by a high-brightness, high-repetition-rate photocathode electron gun operating in CW mode, and on an array of FELs to which the accelerated beam is distributed, each operating at high repetition rate and with even pulse spacing. Dependent on the experimental requirements, the individualFELs may be configured for either self-amplified spontaneous emission (SASE), seeded highgain harmonic generation (HGHG), echo-enabled harmonic generation (EEHG), or oscillator mode of operation, and will produce high peak and average brightness x-rays with a flexible pulse format ranging from sub-femtoseconds to hundreds of femtoseconds. This new light source would serve a broad community of scientists in many areas of research, similar to existing utilization of storage ring based light sources. To reduce technical risks and constructioncosts, accelerator research, development, and design studies at LBNL target the most critical components and systems of the facility. We are developing a high-repetition-rate low-emittance electron gun, high quantum efficiency photocathodes, and have embarked on design and optimization of the electron beam accelerator, FEL switchyard, and array of FELs. We continue our work on precision timing and synchronization systems critical for time-resolved experiments using pump-probe techniques.

43 PARTICLE ACCELERATORS↗

Shape coexistence in atomic nuclei

Shape coexistence in nuclei appears to be unique in the realm of finite many-body quantum systems. It differs from the various geometrical arrangements that sometimes occur in a molecule in that in a molecule the various arrangements are of the widely separated atomic nuclei. In nuclei the various ''arrangements'' of nucleons involve (sets of) energy eigenstates with different electric quadrupole properties such as moments and transition rates, and different distributions of proton pairs and neutron pairs with respect to their Fermi energies. Sometimes two such structures will ''invert'' as a function of the nucleon number, resulting in a sudden and dramatic change in ground-state properties in neighboring isotopes and isotones. In the first part of this review the theoretical status of coexistence in nuclei is summarized. Two approaches, namely, microscopic shell-model descriptions and mean-field descriptions, are emphasized. The second part of this review presents systematic data, for both even- and odd-mass nuclei, selected to illustrate the various ways in which coexistence is observed in nuclei. The last part of this review looks to future developments and the issue of the universality of coexistence in nuclei. Surprises continue to be discovered. With the major advances in reaching to extremes of proton-neutron number, and the anticipated new ''rare isotope beam'' facilities, guidelines for search and discovery are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fine-structure characteristics in the emittance images of a strongly focusing He{sup +} beam

The phase space distribution of a strongly focused He{sup +} ion beam source equipped with concave multiaperture electrodes was measured using a pepper-pot plate and a Kapton foil. The substructure of 301 merging He beamlets was clearly observed on a footprint of pepper-pot hole at the beam waist, where the beam density was 500 mA/cm{sup 2}. The position and the width of each beamlet substructure show the effect of interference of beamlets with surrounding one.

43 PARTICLE ACCELERATORS↗

The development of inflatable array antennas

The deployable array antenna using an inflatable or thin-membrane structure has been identified as one of the enabling technologies to achieve low-mass, high packaging efficiency, low cost, and reliable deployment for future NASNJPL spacebome high-gain and large aperture antennas. Array antennas, when compared to parabolic reflectors, although suffering from limited bandwidth performance, offer wide-angle beam scanning capability and a more reliable flat “natural” aperture. To demonstrate the feasibility and capability of this low-mass array technology, three antenna concepts using inflatable and thin-membrane structures were initiated in 1997 at JPL and several breadboard units have been successfully developed. These three concepts are (1) the inflatable phased array, (2) the inflatable reflectarray, and (3) frame-supported thin membrane array antenna. All three concepts utilize the printed microstrip antenna technology. Although all three concepts will be briefly presented, this paper will discuss in more detail of the recent development of the second concept. The first concept of inflatable phased arrays that have been constructed are 3 to 5-meter size L-band dual-polarized synthetic aperture radar (SAR) arrays for Earth remote sensing application. They all consist of a rectangular configuration with inflatable cylindrical tubes that support and tension a multi-layer thin-membrane radiating aperture with microstrip patches and microstrip power divider lines. For the second concept, an inflatable reflectarray was developed for future deep-space telecom applications. It is a 3m Ka-band inflatable reflectarray (1.8 kg/m2). This reflectarray uses inflated torus tubes to support and tension a flat-membrane reflectarray surface. The reflectarray surface emulates a curved parabolic reflecting surface. However, because of its flat surface being a “natural surface”, it is much easier to achieve and more reliable to maintain the required surface tolerance than that of a curved parabola during long space flight. For the third concept, an L-band dual polarized SAR array with a 5m x 3m aperture and 2.5 kg/m2 of mass has recently been demonstrated. It consists of seven foldable panels each having a rectangular frame that supports a two-layer thinmembrane microstrip subarray aperture. Each frame is made of light-weight graphite composite material. The chief advantage of this deployable “frame” concept is that each frame is able to rigidly support an appropriate number of T/R modules and phase shifters to achieve the desired power distribution and beam scanning. Several technology challenges, such as the development of rigidizable inflatable tubes, a controlled deployment mechanism, thin-membrane thermal effects, a low-mass inflation system, membrane mounted T/R modules, means to counter surface tolerance issues, etc. are being investigated and will be discussed in the presentation. With foreseeable success in the development of these challenging areas, the inflatable/thin-membrane array antennas could be mature enough in a few years for actual space flight.

Lou, Michael↗

Errors introduced in fission neutron spectrum measurements using a single reference

Measurements of physical quantities are often made relative to a reference quantity, simplifying the interpretation of the measurement and its uncertainties. However, if applied without careful considerations, this technique can carry with it a significant and complex systematic error that is usually ignored. For example, measurements of continuous neutron spectra relative to a reference spectrum yield a result that does not properly include the important effects of neutron scattering in the experimental environment. These effects act to distort the measured spectrum shape and create notable errors in spectrum-integrated quantities. While this effect is one of a series of known potential sources of systematic error including, but not limited to target impurities, angular distributions, incident beam flux, and others, the error introduced from differences in environmental scattering effects between the reference and desired spectra are frequently overlooked. In this work, we demonstrate the origin of this error using simulated data corresponding to measurements of the neutron-induced prompt fission neutron spectra of 233 U, 235 U, 238 U, and 239 Pu as well as the spontaneous fission neutron spectrum of 252 Cf. Errors in the spectrum shape can be as high as 10%–15% depending on the combination of incident and outgoing neutron energy. The spectrum integral and average spectrum energy also contain errors that change with incident neutron energy and can be as high as ~2%. Although this study is based on simulated data, we also show a method for proving that this error exists in an experimental data set and we show a correction that can be applied to results of this type to obtain a more accurate result, thereby largely removing systematic errors from environmental scattering effects. The potential for these kinds of errors should be considered in measurements producing continuous neutron spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid three-dimensional imaging of defect distributions using a high-intensity positron microbeam

An intense positron microbeam generated by an electron accelerator has been developed for obtaining three-dimensional positron lifetime mappings in a sample to permit visual evaluation of defect distributions. The beam diameter at the sample was 80-100 {mu}m. The counting rate of the positron annihilation {gamma} rays used to measure positron lifetime was as large as 3x10{sup 3} s{sup -1}. Three-dimensional imaging was demonstrated of positron lifetimes in a SiO{sub 2} sample, which was irradiated with ion beams through a mesh mask. The time to obtain a single image (3500 pixels for an area of 2.5x3.5 mm{sup 2}) was 0.5-1 h.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vacuum electron acceleration by tightly focused laser pulses with nanoscale targets

Electron acceleration using a tightly focused relativistic short laser pulse interacting with a spherical nanocluster, ultrathin foil or preformed mid-dense plasmas is studied by using three-dimensional particle-in-cell simulations with the Stratton-Chu integrals as the boundary conditions for the incident laser fields. The investigation is performed in the regime where the focal spot size is comparable with the laser wavelength. Generation of high-energy electron multibunch jets with quasimonoenergetic or waterbaglike spectra has been demonstrated. The physical process of acceleration and bunching of the electrons is discussed in detail, as well as particles energy and angular distributions for different laser intensities, focusing optics, target parameters, and laser incidence angles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Velocity map imaging of HBr photodissociation in large rare gas clusters

We have implemented the velocity map imaging technique to study clustering in the pulsed supersonic expansions of hydrogen bromide in helium, argon, and xenon. The expansions are characterized by direct imaging of the beam velocity distributions. We have investigated the cluster generation by means of UV photodissociation and photoionization of HBr molecules. Two distinct features appear in the hydrogen atom photofragment images in the clustering regime: (i) photofragments with near zero kinetic energies and (ii) ''hot'' photofragments originating from vibrationally excited HBr molecules. The origin of both features is attributed to the fragment caging by the cluster. We discuss the nature of the formed clusters based on the change of the photofragment images with the expansion parameters and on the photoionization mass spectra and conclude that single HBr molecule encompassed with rare gas ''snowball'' is consistent with the experimental observations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion energy distribution functions of low energy beams formed by wire extraction electrodes

The two-electrode extractor system made of 0.1 mm diameter tungsten wires separated by 0.7 mm has formed an argon ion beam with 50 V extraction potential. Energy spreads of the extracted beams were typically less than 2 eV when the beam current density was low. The beam intensity rapidly decreased as the distance between the extractor and the beam detector increased, indicating space charge limited transport of the beam. Problems associated with the emittance measurements are also discussed.

43 PARTICLE ACCELERATORS↗

Proton emission from thin hydrogenated targets irradiated by laser pulses at 10{sup 16} W/cm{sup 2}

The iodine laser at PALS Laboratory in Prague, operating at 1315 nm fundamental harmonics and at 300 ps FWHM pulse length, is employed to irradiate thin hydrogenated targets placed in vacuum at intensities on the order of 10{sup 16} W/cm{sup 2}. The laser-generated plasma is investigated in terms of proton and ion emission in the forward and backward directions. The time-of-flight technique, using ion collectors and semiconductor detectors, is used to measure the ion currents and the corresponding velocities and energies. Thomson parabola spectrometer is employed to separate the contribution of the ion emission from single laser shots. A particular attention is given to the proton production in terms of the maximum energy, emission yield, and angular distribution as a function of the laser energy, focal position, target thickness, and composition. Metallic and polymeric targets allow to generate protons with large energy range and different yield, depending on the laser, target composition, and target geometry properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Absolute calibration of two DRZ phosphor screens using ultrashort electron bunch

This article gives the absolute calibration of two types phosphor screens (DRZ) that were used to detect and characterize electron bunches driven by laser-plasma accelerator. The test was performed with picoseconds electron bunch at a radio frequency linear electron accelerator in Tsinghua University. The photons emitted from DRZ screens showed good linear responses to the charge of incident electron bunch and cosine angular distribution in space. An energy conversional efficiency of effective scintillant matter was also calculated.

43 PARTICLE ACCELERATORS↗