Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Simple Carotid-Sparing Intensity-Modulated Radiotherapy Technique and Preliminary Experience for T1-2 Glottic Cancer

Purpose: To investigate the dosimetry and feasibility of carotid-sparing intensity-modulated radiotherapy (IMRT) for early glottic cancer and to report preliminary clinical experience. Methods and Materials: Digital Imaging and Communications in Medicine radiotherapy (DICOM-RT) datasets from 6 T1-2 conventionally treated glottic cancer patients were used to create both conventional IMRT plans. We developed a simplified IMRT planning algorithm with three fields and limited segments. Conventional and IMRT plans were compared using generalized equivalent uniform dose and dose-volume parameters for in-field carotid arteries, target volumes, and organs at risk. We have treated 11 patients with this simplified IMRT technique. Results: Intensity-modulated radiotherapy consistently reduced radiation dose to the carotid arteries (p < 0.05) while maintaining the clinical target volume coverage. With conventional planning, median carotid V35, V50, and V63 were 100%, 100%, and 69.0%, respectively. With IMRT planning these decreased to 2%, 0%, and 0%, respectively (p < 0.01). Radiation planning and treatment times were similar for conventional radiotherapy and IMRT. Treatment results have been excellent thus far. Conclusions: Intensity-modulated radiotherapy significantly reduced unnecessary radiation dose to the carotid arteries compared with conventional lateral fields while maintaining clinical target volume coverage. Further experience and longer follow-up will be required to demonstrate outcomes for cancer control and carotid artery effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adiabatically driven frequency conversion towards short extreme-ultraviolet radiation pulses

We present an experimental demonstration of sum-frequency generation toward tunable picosecond, broadband radiation pulses in the extreme-ultraviolet regime, supported by adiabatically prepared atomic coherences. We drive a two-photon transition in a dense medium of xenon atoms with a long (nanosecond) pump laser pulse at the Fourier-transform-limited bandwidth and with a wavelength of 225 nm. The frequency of the pump pulse is slightly detuned from exact two-photon resonance. In this configuration, the medium is adiabatically driven by a process of coherent population return. The adiabatic passage process generates a maximal coherent superposition of two quantum states with large energy spacing. An additional, short (picosecond) probe laser pulse at a wavelength of 540 nm beats with the maximal atomic coherence and generates a short (picosecond) signal radiation pulse at 93 nm. As compared to conventional (diabatic) frequency conversion, the adiabatically driven maximal atomic coherence yields enhanced conversion efficiency and significantly enhanced stability.

74 ATOMIC AND MOLECULAR PHYSICS↗

Definitive Management of Oligometastatic Melanoma in a Murine Model Using Combined Ablative Radiation Therapy and Viral Immunotherapy

Purpose: The oligometastatic state is an intermediate state between a malignancy that can be completely eradicated with conventional modalities and one in which a palliative approach is undertaken. Clinically, high rates of local tumor control are possible with stereotactic ablative radiation therapy (SABR), using precisely targeted, high-dose, low-fraction radiation therapy. However, in oligometastatic melanoma, virtually all patients develop progression systemically at sites not initially treated with ablative radiation therapy that cannot be managed with conventional chemotherapy and immunotherapy. We have demonstrated in mice that intravenous administration of vesicular stomatitis virus (VSV) expressing defined tumor-associated antigens (TAAs) generates systemic immune responses capable of clearing established tumors. Therefore, in the present preclinical study, we tested whether the combination of systemic VSV-mediated antigen delivery and SABR would be effective against oligometastatic disease. Methods and Materials: We generated a model of oligometastatic melanoma in C57BL/6 immunocompetent mice and then used a combination of SABR and systemically administered VSV-TAA viral immunotherapy to treat both local and systemic disease. Results: Our data showed that SABR generates excellent control or cure of local, clinically detectable, and accessible tumor through direct cell ablation. Also, the immunotherapeutic activity of systemically administered VSV-TAA generated T-cell responses that cleared subclinical metastatic tumors. We also showed that SABR induced weak T-cell-mediated tumor responses, which, particularly if boosted by VSV-TAA, might contribute to control of local and systemic disease. In addition, VSV-TAA therapy alone had significant effects on control of both local and metastatic tumors. Conclusions: We have shown in the present preliminary murine study using a single tumor model that this approach represents an effective, complementary combination therapy model that addresses the need for both systemic and local control in oligometastatic melanoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3D-printed sheet jet for stable megahertz liquid sample delivery at X-ray free-electron lasers

X-ray free-electron lasers (XFELs) can probe chemical and biological reactions as they unfold with unprecedented spatial and temporal resolution. A principal challenge in this pursuit involves the delivery of samples to the X-ray interaction point in such a way that produces data of the highest possible quality and with maximal efficiency. This is hampered by intrinsic constraints posed by the light source and operation within a beamline environment. For liquid samples, the solution typically involves some form of high-speed liquid jet, capable of keeping up with the rate of X-ray pulses. However, conventional jets are not ideal because of radiation-induced explosions of the jet, as well as their cylindrical geometry combined with the X-ray pointing instability of many beamlines which causes the interaction volume to differ for every pulse. This complicates data analysis and contributes to measurement errors. An alternative geometry is a liquid sheet jet which, with its constant thickness over large areas, eliminates the problems related to X-ray pointing. Since liquid sheets can be made very thin, the radiation-induced explosion is reduced, boosting their stability. These are especially attractive for experiments which benefit from small interaction volumes such as fluctuation X-ray scattering and several types of spectroscopy. Although their use has increased for soft X-ray applications in recent years, there has not yet been wide-scale adoption at XFELs. Here, gas-accelerated liquid sheet jet sample injection is demonstrated at the European XFEL SPB/SFX nano focus beamline. Its performance relative to a conventional liquid jet is evaluated and superior performance across several key factors has been found. This includes a thickness profile ranging from hundreds of nanometres to 60 nm, a fourfold increase in background stability and favorable radiation-induced explosion dynamics at high repetition rates up to 1.13 MHz. Its minute thickness also suggests that ultrafast single-particle solution scattering is a possibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method and apparatus for generating coherent radiation in the ultra-violet region and above by use of distributed feedback

Helium in the superfluid state emits copious amounts of radiation in the ultraviolet region when excited by an electron stream. Conventional laser action using mirrors is impossible in superfluid helium because there are no mirrors that will reflect VUV radiation. By utilizing the distributed feedback method, the superfluid helium can be made to lase. By setting up a standing wave in superfluid helium that has a wavelength equal to, or harmonically related to, half the wavelength of the photon radiation chosen to be emitted as laser radiation by the superfluid helium, the need for end mirrors to produce reflection of the laser radiation is eliminated and reflection occurs instead at the wavefronts of the standing wave. The photons leave the superfluid helium at right angles to the standing wave as coherent radiation having a very high intensity. The standing wave established in the superfluid helium may be an acoustical standing wave, a thermal standing wave (second sound), or an electric standing wave.

Saffren, M. M.↗

Gauged global strings

We investigate the string solutions and cosmological implications of the gauge U(1) Z × global U(1) PQ model. With two hierarchical symmetry-breaking scales, the model exhibits three distinct string solutions: a conventional global string, a global string with a heavy core, and a gauge string as a bound state of the two global strings. This model reveals rich phenomenological implications in cosmology. During the evolution of the universe, these three types of strings can form a Y-junction configuration. Intriguingly, when incorporating this model with the QCD axion framework, the heavy-core global strings emit more axion particles compared to conventional axion cosmic strings due to their higher tension. This radiation significantly enhances the QCD axion dark matter abundance, thereby opening up the QCD axion mass window. Consequently, axions with masses exceeding ~ 10 −5 eV have the potential to constitute the whole dark matter abundance. Furthermore, in contrast to conventional gauge strings, the gauge strings in this model exhibit a distinctive behavior by radiating axions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Image-Guided Stereotactic Spine Radiosurgery on a Conventional Linear Accelerator

Stereotactic radiosurgery for spinal metastasis consists of a high radiation dose delivered to the tumor in 1 to 5 fractions. Due to the high radiation dose in a single or fewer treatments, the precision of tumor localization and dose delivery is of great concern. Many groups have published their experiences of spinal radiosurgery with the use of CyberKnife System (Accuray Inc.). In this study, we report in detail our approach to stereotactic spine radiosurgery (SSRS) using a conventional linear accelerator (Varian Trilogy), utilizing the features of kilovolt on-board imaging (kV-OBI) and cone beam computed tomography (CBCT) for image guidance. We present our experience in various aspects of the SSRS procedure, including patient simulation and immobilization, intensity-modulated radiation treatment (IMRT) planning and beam selection, portal dosimetry for patient planning quality assurance (QA), and the use of image guidance in tumor localization prior to and during treatment delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Thermal Neutron Captures on d and {sup 3}He

We report on a study of the nd and n{sup 3}He radiative captures at thermal neutron energies, using wave functions obtained from either chiral or conventional two- and three-nucleon realistic potentials with the hyperspherical-harmonics method, and electromagnetic currents derived in chiral effective field theory up to one loop. The predicted nd and n{sup 3}He cross sections are in good agreement with data, but exhibit a significant dependence on the input Hamiltonian. A comparison is also made between these and new results for the nd and n{sup 3}He cross sections obtained in the conventional framework for both potentials and currents.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dosimetric Factors and Toxicity in Highly Conformal Thoracic Reirradiation

Purpose: We determined cumulative dose to critical structures, rates of toxicity, and outcomes following thoracic reirradiation. Methods and Materials: We retrospectively reviewed our institutional database for patients treated between 2008 and 2014, who received thoracic reirradiation with overlap of 25% prescribed isodose lines. Patients received courses of hyperfractionated (n=5), hypofractionated (n=5), conventionally fractionated (n=21), or stereotactic ablative radiation therapy (n=51). Doses to critical structures were converted to biologically effective dose, expressed as 2 Gy per fraction equivalent dose (EQD2; α/β = 2 for spinal cord; α/β = 3 for other critical structures). Results: We identified 82 courses (44 for retreatment) in 38 patients reirradiated at a median 16 months (range: 1-71 months) following initial RT. Median follow-up was 17 months (range: 3-57 months). Twelve- and 24-month overall survival rates were 79.6% and 57.3%, respectively. Eighteen patients received reirradiation for locoregionally recurrent non-small cell lung cancer with 12-month rates of local failure and regional recurrence and distant metastases rates of 13.5%, 8.1%, and 15.6%, respectively. Critical structures receiving ≥75 Gy EQD2 included spinal cord (1 cm{sup 3}; n=1), esophagus (1 cm{sup 3}; n=10), trachea (1 cm{sup 3}; n=11), heart (1 cm{sup 3}; n=9), aorta (1 cm{sup 3}; n=16), superior vena cava (1 cm{sup 3}; n=12), brachial plexus (0.2 cm{sup 3}; n=2), vagus nerve (0.2 cm{sup 3}; n=7), sympathetic trunk (0.2 cm{sup 3}; n=4), chest wall (30 cm{sup 3}; n=12), and proximal bronchial tree (1 cm{sup 3}; n=17). Cumulative dose-volume (D cm{sup 3}) toxicity following reirradiation data included esophagitis grade ≥2 (n=3, D1 cm{sup 3} range: 41.0-100.6 Gy), chest wall grade ≥2 (n=4; D30 cm{sup 3} range: 35.0-117.2 Gy), lung grade 2 (n=7; V20{sub combined-lung} range: 4.7%-21.7%), vocal cord paralysis (n=2; vagus nerve D0.2 cm{sup 3} range: 207.5-302.2 Gy), brachial plexopathy (n=1; D0.2 cm{sup 3} = 242.5 Gy), and Horner's syndrome (n=1; sympathetic trunk D0.2 cm{sup 3} = 130.8 Gy). No grade ≥4 toxicity was observed. Conclusions: Overlapping courses of reirradiation can be safely delivered with acceptable toxicity. Some toxicities occurred acutely at doses considered safe for a single course of therapy (esophagus). We observed rib fracture, brachial plexopathy, and Horner's syndrome for patients receiving high cumulative doses to corresponding critical structures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simultaneously Synchrotron X-ray Fluorescence and Ptychographic Imaging of Frozen Biological Single Cells

Bionanoprobe (BNP), a hard x-ray fluorescence sample-scanning nanoprobe at the Advanced Photon Source of Argonne National Laboratory, has been used to quantitatively study elemental distributions in biological cells with sub-100 nm spatial resolution and high sensitivity. Cryogenic conditions enable biological samples to be studied in their frozen-hydrated state with both ultrastructure and elemental distributions more faithfully preserved compared to conventional chemical fixation or dehydration methods. Furthermore, radiation damage is reduced in two ways: the diffusion rate of free radicals is decreased at low temperatures; and the sample is embedded in vitrified ice, which reduces mass loss.

59 BASIC BIOLOGICAL SCIENCES↗

Testing ice microphysics parameterizations in the NCAR Community Atmospheric Model Version 3 using Tropical Warm Pool–International Cloud Experiment data

Cloud properties have been simulated with a new double-moment microphysics scheme under the framework of the single column version of NCAR CAM3. For comparisons, the same simulation was made with the standard single-moment microphysics scheme of CAM3. Results from both simulations were compared favorably with observations during the Tropical Warm Pool- International Cloud Experiment by US Department of Energy Atmospheric Radiation Program in terms of the temporal variation and vertical distribution of cloud fraction and cloud condensate. Major differences between the two simulations are in the magnitude and distribution of ice water content within the mixed-phase cloud during the monsoon period, though the total frozen water (snow plus ice) content is similar. The ice mass content in the mixed-phase cloud from the new scheme is larger than that from the standard scheme, and extends 2 km further downward, which are closer to observations. The dependence of the frozen water mass fraction in total condensate on temperature from the new scheme is also closer to available observations. Outgoing longwave radiation (OLR) at the top of the atmosphere (TOA) from the simulation with the new scheme is in general larger than that with the standard scheme, while the surface downward longwave radiation is similar. Sensitivity tests suggest that different treatments of the ice effective radius contribute significantly to the difference in the TOA OLR in addition to cloud water path. The deep convection process affects both TOA OLR and surface downward longwave radiation. The over-frequently-triggered deep convention process in the model is not the only mechanism for the excess middle and high level clouds. Further evaluation especially for ice cloud properties based on in-situ data is needed.

54 ENVIRONMENTAL SCIENCES↗

Electronic modulation of infrared radiation in graphene plasmonic resonators

All matter at finite temperatures emits electromagnetic radiation due to the thermally induced motion of particles and quasiparticles. Dynamic control of this radiation could enable the design of novel infrared sources; however, the spectral characteristics of the radiated power are dictated by the electromagnetic energy density and emissivity, which are ordinarily fixed properties of the material and temperature. Here we experimentally demonstrate tunable electronic control of blackbody emission from graphene plasmonic resonators on a silicon nitride substrate. It is shown that the graphene resonators produce antenna-coupled blackbody radiation, which manifests as narrow spectral emission peaks in the mid-infrared. By continuously varying the nanoresonator carrier density, the frequency and intensity of these spectral features can be modulated via an electrostatic gate. This work opens the door for future devices that may control blackbody radiation at timescales beyond the limits of conventional thermo-optic modulation.

36 MATERIALS SCIENCE↗

Laser based 100 GeV electron acceleration scheme for muon production

High energy muons, due to their unique ability to penetrate deeply into matter, can enable radiography of structures that cannot be probed by other forms of radiation. Current terrestrial sources of muons require conventional GeV-TeV particle accelerators which are hundreds to thousands of meters in size. Laser wakefield acceleration (LWFA) can achieve acceleration gradients of two-to-three orders of magnitude greater than conventional accelerators, thus shrinking the accelerator to a number of meters. We propose a concept for a compact muon source based on the first self-consistent PIC simulations of an all optical LWFA that uses a guiding channel to achieve electron energies of 100 GeV in a distance of 6 m with a driving laser energy of 300 J in a single stage. From the resulting electron energy spectrum we estimate muon production for this source. We show that this accelerator, coupled with high average power laser driver technology, provides the basis for a high energy and high flux muon source.

laser-produced plasmas↗

Dark Matter Candidates: A Status Report

A brief review is given of various dark matter candidates. In particular, some of the most studied candidates like axions, inert Higgs doublet, sterile neutrinos, supersymmetric particles and Kaluza-Klein particles are discussed. In particular, indirect detection methods are reviewed, with gamma-ray detection being a particularly important method. The situation also for indirect detection through antimatter cosmic rays has recently become quite interesting with new results having dark matter as one of the possible explanations. Problems of this explanation and possible solutions are discussed, and the importance of new measurements is emphasized. If the explanation is indeed dark matter, some unusual and unexpected properties would be needed. One should always keep the possible 'conventional' astrophysical explanations, like electron and positron radiation from pulsars in mind. To get a conclusive case for dark matter, detection in other channels will likely be needed, such as direct detection or detection of angular and spectral signatures in gamma-rays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Theoretical efficiency limits for thermoradiative energy conversion

A new method to produce electricity from heat called thermoradiative energy conversion is analyzed. The method is based on sustaining a difference in the chemical potential for electron populations above and below an energy gap and let this difference drive a current through an electric circuit. The difference in chemical potential originates from an imbalance in the excitation and de-excitation of electrons across the energy gap. The method has similarities to thermophotovoltaics and conventional photovoltaics. While photovoltaic cells absorb thermal radiation from a body with higher temperature than the cell itself, thermoradiative cells are hot during operation and emit a net outflow of photons to colder surroundings. A thermoradiative cell with an energy gap of 0.25 eV at a temperature of 500 K in surroundings at 300 K is found to have a theoretical efficiency limit of 33.2%. For a high-temperature thermoradiative cell with an energy gap of 0.4 eV, a theoretical efficiency close to 50% is found while the cell produces 1000 W/m{sup 2} has a temperature of 1000 K and is placed in surroundings with a temperature of 300 K. Some aspects related to the practical implementation of the concept are discussed and some challenges are addressed. It is, for example, obvious that there is an upper boundary for the temperature under which solid state devices can work properly over time. No conclusions are drawn with regard to such practical boundaries, because the work is aimed at establishing upper limits for ideal thermoradiative devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Aspects of gravitational portals and freeze-in during reheating

We conduct a systematic investigation of freeze-in during reheating while taking care to include both direct and indirect production of dark matter (DM) via gravitational portals and inflaton decay. Direct production of DM can occur via gravitational scattering of the inflaton, while indirect production occurs through scattering in the Standard Model radiation bath. We consider two main contributions to the radiation bath during reheating. The first, which may dominate at the onset of the reheating process, is produced via gravitational scattering of the inflaton. The second (and more standard contribution) comes from inflaton decay. We consider a broad class of DM production rates parametrized as R χ ∝ T n + 6 / Λ n + 2 , and inflaton potentials with a power-law form V ( ϕ ) ∝ ϕ k about the minimum. We find the relic density produced by freeze-in for each contribution to the Standard Model bath for arbitrary k and n , and compare these with the DM density produced gravitationally by inflaton scattering. We find that freeze-in production from the gravitationally produced radiation bath can exceed that of the conventional decay bath and account for the observed relic density provided that m χ > T RH , with additional k - and n -dependent constraints. For each freeze-in interaction considered, we also find m χ - and T RH -dependent limits on the beyond the Standard Model scale, Λ , for which gravitational production will exceed ordinary freeze-in production. Published by the American Physical Society 2025

Henrich, Stephen E. (ORCID:0000000323669519)↗

WE-FG-207B-07: Feasibility of Low Dose Lung Cancer Screening with a Whole-Body Photon Counting CT: First Human Results

Purpose: To evaluate the feasibility of using a whole-body photon counting detector (PCD) CT scanner for low dose lung cancer screening compared to a conventional energy integrating detector (EID) system. Methods: Radiation dose-matched EID and PCD scans of the COPDGene 2 phantom and 2 human volunteers were acquired. Phantom images were acquired at different radiation dose levels (CTDIvol: 3.0, 1.5, and 0.75 mGy) and different tube voltages (120, 100, and 80 kVp), while human images were acquired at vendor recommended low-dose lung cancer screening settings. EID and PCD images were compared for quantitative Hounsfield unit accuracy, noise levels, and contrast-to-noise ratios (CNR) for detection of ground-glass nodules (GGNs) and emphysema. Results: The PCD Hounsfield unit accuracy was better for water at all scan parameters, and for lung, GGN and emphysema equivalent regions of interest (ROIs) at 1.5 and 0.75 mGy. PCD attenuation accuracy was more consistent for all scan parameters (all P<0.01), while Hounsfield units for lung, GGN and emphysema ROIs changed significantly for EID with decreasing dose (all P<0.001). PCD showed lower noise levels at the lowest dose setting at 120, 100 and 80 kVp (15.2±0.3 vs 15.8±0.2, P=0.03; 16.1±0.3 vs 18.0±0.4, P=0.003; and 16.1±0.3 vs 17.9±0.3, P=0.001, respectively), resulting in superior CNR for the detection of GGNs and emphysema at 100 and 80 kVp. Significantly lower PCD noise levels were confirmed in volunteer images. Conclusion: PCD provided better Hounsfield unit accuracy for lung, ground-glass, and emphysema-equivalent foams at 1.5 and 0.75 mGy with less variability than EID. Additionally, PCD showed less noise, and higher CNR at 0.75 mGy for both 100 and 80 kVp. PCD technology may help reduce radiation exposure in lung cancer screening while maintaining diagnostic quality.

60 APPLIED LIFE SCIENCES↗