Search NASA⌕ Search

SEARCH · Search NASA

Results for “CORROSION TEST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Operando carbon corrosion measurements in fuel cells using boron-doped carbon supports

Carbonaceous materials are the most common catalyst supports in proton exchange membrane fuel cell (PEMFCs), yet their corrosion is one of the limiting factors in achieving high durability. Herein, we doped carbon supports with boron (B) to increase the corrosion-resistance of the support. Two types of B-doped carbons were synthesized and studied as platinum support materials. Further, they varied in their morphologies, surface areas, and the types of boron species. The durability of Pt/B-doped carbon catalysts was investigated using the US-DOE catalysts’ supports accelerated stress test (AST) and a mass-spectrometer connected to the fuel cell effluent stream to quantify the mass of corroded carbon support in operando. The addition of boron to the carbon increased the stability of Pt catalysts in long-term usage of PEMFC. After 4000 AST cycles, more than 50% of initial current density was preserved for the boron-containing systems, while less than 30% of it remained with Vulcan carbon (Pt/V). Also, the Pt/B-doped carbon samples demonstrated better electrochemical active surface area (ECSA) stability when compared to Pt/V. Carbon loss measurements showed that B-doped carbons have higher resistance to electrochemical corrosion than unmodified carbon. Specifically, the substitutional boron-doped carbon demonstrated an extremely high stability and low corrosion rate.

25 ENERGY STORAGE↗

Overall Performance Losses and Activated Mechanisms in Double Glass and Glass-backsheet Photovoltaic Modules with Monofacial and Bifacial PERC Cells, under Accelerated Exposures

Commercial PV modules have various packaging choices nowadays, which influence their long-term reliability. This study compared the degradation behaviors of sixteen module variants from two brands with varying encapsulant materials (EVA or POE), encapsulant types, module architectures (GB or DG), and cell types (monofacial or bifacial) using null hypothesis testing to determine statistical significant findings. The modules were exposed for 2,520 hours under two accelerated exposures: modified damp heat (mDH) and modified damp heat with full-spectrum light (mDH+FSL). For both brands, two DG module variants with UV-Cutoff rear encapsulant are found to have significantly lower average power loss than the module variants of EVA+GB with opaque rear encapsulant after each accelerated exposure. Metallization interconnect corrosion is identified as the primary degradation mechanism. Furthermore, unsupervised hierarchical clustering finds that the degradation behaviors of modules from one brand with a more strict manufacturing quality control depends on module architectures only.

14 SOLAR ENERGY↗

Predicted Fracture Tendency of Naturally Occurring Aluminum Surface Coatings under Tensile Loading

Naturally occurring coatings on aluminum metal, such as its oxide or hydroxide, serve to protect the material from corrosion. Understanding the conditions under which these coatings mechanically fail is therefore expected to be an important aspect of predictive models for aluminum component lifetimes. To this end, we develop and apply a molecular dynamics (MD) modeling framework for conducting tension tests that is capable of isolating factors governing the mechanical strength as a function of coating chemistry, defect morphology, and variables associated with the loading path. We consider two representative materials, including γ-Al 2 O 3 and γ-Al(OH) 3 (i.e., oxide and hydroxide), both of which form readily as aluminum surface coatings. Our results indicate that defects have a significant bearing on the strength of aluminum oxide, with grain boundaries serving to reduce the strain at failure from ε zz = 0.300 to 0.219, relative to perfect single crystal. Our simulations also predict that porosity lowers the elastic stiffness and yield strength of the oxide. Relative to perfect crystal, we find porosity factors of 5%, 10% and 20% decrease the yield stress by 26%, 36% and 53%, respectively. MD predicts that perfect hydroxide and oxide single crystal have respective strains at failure of 0.08 and 0.31 under tensile uniaxial strain loading, and that the corresponding yield stresses are respectively 1.6 and 11.1 GPa. These data indicate that the hydroxide is substantially more susceptible to mechanical failure than the oxide. Our results, coupled with literature findings that indicate hot and humid conditions favor formation of hydroxide and defective oxide coatings, indicate the potential for a complicated dependence of aluminum corrosion susceptibility and stress corrosion cracking on aging history.

36 MATERIALS SCIENCE↗

Corrosion of U233-Doped Uranium Oxide using Microfluidics Methods

The aim of work this year has been to investigate the role of alpha (α)-radiation and hydrogen (H 2 ) on the corrosion of uranium oxide (UO 2 ) using a microfluidic device. The microfluidic device, termed the Particle-Attached Microfluidic Electrochemical Cell, (PAMEC), enables monitoring of the UO 2 electrochemical corrosion potential (E corr ) under different environments, including de-aerated conditions and in the presence of dissolved H 2 . The Si 3 N 4 window allows us to study morphological and chemical changes under an electron microscope. We have previously demonstrated that the PAMEC matches the results from bulk electrochemical tests with UO 2 [1]. We used the high specific activity uranium (U) isotope, 233 U, (t 1/2 = 160,000 years) incorporated into UO 2 , to generate a localized a-field. The objective of the experiments were to mimic the radiation environment that would be experience at the surface of aged spent nuclear fuel (SNF) during long-term geologic disposal under anoxic conditions. Wittman et al. [2] predicted that in the presence of a pure a-radiation field and under H 2 conditions, the concentration of the radiolytic oxidant H 2 O 2 would be suppressed or even eliminated. In a UO 2 corrosion experiment this would be exhibited through a lowering of the measured UO 2 corrosion potential compared to identical conditions in the absence of dissolved H 2 . We found that the predictions of Wittman and co-workers were supported and that the corrosion potential of the 233 U-doped UO 2 in solution lowered with presence of H 2 gas and increased in the absence of H 2 , when under anoxic conditions. The PAMEC experiments indicate that H 2 O 2 has been eliminated in a solution sparged with H 2 while exposed to an a-radiation field. The corrosion potential of the a-doped 233 U(10%)- 238 UO 2 in a solution sparged with Ar/H 2 matched the corrosion potential of 238 UO 2 in solution sparged with air. This clearly demonstrated that the H 2 O 2 had been eliminated and that the only oxidant present was O 2 in this system in complete agreement with the modeling results of Wittman et al. These results point to the need to improve the Fuel Matrix Degradation (FMD) Process Model training data set that is being used in the FMD surrogate model that is being developed for the repository program. The incorporation of realistic radiation chemistry will improve the scientific basis for the FMD Model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fatigue Testing and Characterization of Pre-hydrided Zircaloy-4 Cladding Tubes

The solubility of hydrogen in Zircaloy-4 (Zry-4) at the cladding operating temperature is near 100 wt. ppm. Above this solubility limit, excess hydrogen precipitates as δ-hydride platelets in the cladding material. Because of the effect of the thermal gradient across the cladding thickness on the migration and precipitation of hydrogen, hydride rims are often observed at the cladding outer surface; under excessive corrosion conditions hydride blisters are possible. It is well known that the fatigue of metal alloys, especially high cycle fatigue, is sensitive to the status of surface including the microstructure, roughness, and residual stress. Thus, the question considered herein, is whether excessive hydrogen pickup modifies the microstructure such that it has a degradation effect on the fatigue performance of cladding during operation. This report describes the evaluation of fatigue performance of a pre-hydrided Zry-4 cladding. A commercial Zry-4 was polished and pre-hydrided to 800 ppm and 1300 ppm H contents. The fatigue testing was conducted under strain control at 5 Hz with fully-reversed bending by using a cyclic integrated reversible bending fatigue tester (CIRFT). Six specimens with 1300 ppm and one specimen with 800 ppm were tested. Significant variation in test results were observed. While two of the 1300 ppm specimens failed with less than 1 ×10 5 cycles (at 0.32% and 0.41%), the four other samples did not fail over the strain amplitude range of 0.25% to 0.38%. Interestingly, the fracture initiation site of the failed samples was on the outside diameter (OD) surface rather than on the inside diameter (ID) surface as is typical for the as-polished cladding. This suggested a degrading effect of the hydriding process. Subsequently, three of the unfailed specimens were then further tested at ~0.43% to observe where failure initiation occurred. Significant variation was also observed in these three specimens. One specimen failed at ~9000 cycles while the two others failed at 43000 and 1.06 ×10 5 cycles. The performance here correlated to the location of failure initiation; failure initiated on the OD in the sample that failed after 9000 cycles while it initiated on the ID in the sample that failed after 43000 and 1.06 ×10 5 cycles. Flat features at the OD initiation sites suggest a brittle hydride feature on the surface of those samples was the cause of the degradation in fatigue performance, though the overall hydrogen levels in all samples was similar. A summary of all the observations is provided below: • The un-failed specimens with 1300 ppm H were cycled to failure with a higher amplitude near 0.43%. In addition, the fatigue-treated specimen tended to have a longer fatigue at the same induced amplitude. • Fractography revealed a mixed failure mode for the pre-hydrided specimen. Particularly, the specimen with fracture initiation site (FIS) located on the outer diameter surface of tube tended to have a shorter fatigue life than that of FIS on the inner diameter surface. • Etched cross section was shown to have hydride platelets aligned with tube longitudinal axis as expected, and the density of hydrides is at the similar level as in literature data. Meanwhile, a LECO procedure was applied for hydrogen concentration measurement, which showed the measured hydrogen contents are close to the nominal value. • With the polished cladding tube as baseline, O’Donnell-Lager (O-L) analysis showed that a decrease of about 50% in reduction-of-area (RA) would be needed for the O-L fitting to the fatigue data of 1300 ppm cladding. The suggestion for the next steps is provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of Al:Si and (Al+Na):Si ratios on the static corrosion of sodium‐boroaluminosilicate glasses

Abstract Understanding alteration mechanisms of borosilicate glasses in aqueous media is essential to nuclear waste performance assessments to ensure radioisotopes are contained for extended durations. Aluminum is typically added to glass compositions to reduce the extent of alteration. However, previous work on 7‐day durability tests has suggested that Al has a nonlinear relationship with extent of alteration. The effects of Al:Si and (Al+Na):Si substitutions on glass durability were evaluated using series of glasses based on the International Simple Glass corroded in static conditions up to 13 months in deionized water at 90°C. The alteration behavior was determined by measurement of element release in solution. The ⁓7‐day alteration trends across the series were consistent with predicted trends. The 13‐month results indicated overall alteration decreased as Al:Si ratios increased and was unaffected by changes in (Al+Na):Si except for the glass with the highest (Al+Na):Si ratio (ISG‐A23N), which completely altered within 14 days. Frequent sampling and in situ Raman measurements of solutions revealed ISG‐A23N experienced several distinguishable alteration rate regimes within 7 days, forming a ⁓100 µm alteration layer and a NaSiAlO 4 zeolite.

Reiser, Joelle T.↗

Neutron-Friendly Li-Ion Battery Coin Cell for In Situ 3D Visualization of Li Plating

Advanced battery characterization using in situ/operando neutron imaging is critical for uncovering degradation modes such as lithium (Li) plating in Li-ion batteries (LIBs). However, conventional LIBs hinder operando neutron radiography (NR) and in situ neutron micro-computed tomography (N-μCT) for visualizing Li plating near the graphite-separator interface due to strong attenuation from hydrogen-rich components like PP–PE–PP separators, electrolyte, and Fe-based spacers. In this work, we designed and tested a neutron-friendly battery (NFB) optimized for in situ Li detection during extreme fast charging (XFC). Guided by neutron attenuation cross-sections and material transmission, the NFB enables clear visualization at the graphite–separator interface, which is typically opaque in standard LIBs. Electrochemical tests show the NFB exhibits voltage/current responses like standard cells for up to 50 XFC cycles. However, its lower reversibility and capacity are likely due to Cu-coated Al spacer degradation from delamination or corrosion. We propose titanium spacers as a more stable alternative, albeit requiring custom machining. Using this optimized cell, we achieved simultaneous neutron tomography of multiple cells, capturing in situ 3D images of dead Li accumulation, particularly near graphite edges. These heterogeneous deposits and disconnected Li clusters suggest localized current density hotspots during XFC.

25 ENERGY STORAGE↗

Comparison of mechanical properties measured on multiple scales

FeCrAl alloys are being developed for accident tolerant fuels for current light water reactors. Specifically as fuel claddings with enhanced safety. These alloys are being developed to have excellent corrosion resistance in light water reactor coolant environments and structural integrity for longer durations in the case of a loss of coolant scenario where time is critical for safety. Tensile, shear punch, and Vickers hardness testing was performed on neutron irradiated FeCrAl alloys with three variations in composition. Testing was done at room temperature for comparison of the three techniques. FeCrAl alloys in this report were irradiated at Oak Ridge National Laboratory (ORNL) in the High Flux Isotope Reactor (HFIR) to 7 dpa and at 320 °C.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TEAMER Technical Support on Biofouling and Corrosion for E-Wave Technologies LLC Novel (Abstract)

National Technology & Engineering Solutions of Sandia (NTESS) in collaboration with the Pacific Northwest National Laboratory (PNNL), and with guidance from E-Wave, will assess corrosion and biofouling challenges specific to E-Wave’s innovative WEC designed to retrofit into and power existing aquaculture farm infrastructure from ocean waves. The teams will examine coatings via a static raw seawater test and determine the efficacy of coatings for E-Wave’s applications. Samples will include panels of materials provided by E-Wave and coated with three different paint treatments. Fouling will be determined using a staining technique followed by photographic analysis to evaluate fouling intensity on the surface. Materials will also be weighed before and after submersion to facilitate weight change analysis resulting from fouling organisms aggregating on the materials.

16 TIDAL AND WAVE POWER↗

Strong degradation of polycarbonate and polystyrene by the CO 2 capture solvent diethyl sebacate

Here, we report on observations of strong degradation of a polycarbonate vessel by a solvent being considered for a CO 2 capture process, diethyl sebacate. This degradation led to failure of a polymeric hollow fiber membrane unit. Additional tests showed rapid degradation of polycarbonate safety glasses and polystyrene-based petri dishes by exposure to diethyl sebacate at ambient conditions. We also report on safe operations with diethyl sebacate in extensive experiments studying the corrosion of steel in CO 2 -pressurized reactors lined with PTFE and using PTFE gaskets. Used diethyl sebacate was also stored for long time periods in bottles made from low-density polyethylene bottles without physical deterioration. These observations indicate that care must be taken in development of new contactors and processes for CO 2 capture with diethyl sebacate and related solvents and in the choice of material for storage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ionic Liquids as Extreme Pressure Additives for Bearing Steel Applications

The protection of steel surfaces from wear under extreme pressure conditions is of major importance in several industries as it provides better performance and longer life of machinery. The motivation for this work was to study the lubrication of steel by ionic liquids (ILs), which have recently emerged as greener alternatives to commercial lubricants and additives. Three ILs based on sulfur-containing anions, used as 2-wt% additives in polyethylene glycol base oil (MW 200; PEG 200), were tested in the lubrication of ASTM 52100 bearing steel contacts in extreme pressure conditions (under mixed lubrication with a Hertzian pressure of 1.12 GPa) using a mini traction machine (MTM). Due to the poor resistance to corrosion of bearing steel, a semi-ester of succinic acid derivative corrosion inhibitor (Lanxess RC 4801) was added to the mixtures at a 1 wt% concentration. The ILs 1-hexyl-methylimidazolium trifluoromethanesulfonate ([C 6 mim][TfO]) and 1-hexyl-4-picolinium trifluoromethanesulfonate ([C 6 -4-pic][TfO]) revealed promising results in terms of surface protection of bearing steel. In contrast, 4-picolinium hydrogen sulfate ([4-picH][HSO 4 ]) as 2-wt% additive to PEG 200 + 1% RC 4801 did not show any improvement in wear performance compared to neat PEG 200 + 1% RC 4801. PEG 200 + 2% [C 6 mim][TfO] + 1%RC 4801 allowed for a decrease in wear up to ~ 76% and PEG 200 + 2% [C 6 -4-pic][TfO] + 1%RC 4801 up to ~ 46% when compared with neat PEG 200 + 1% RC 4801. Optical microscopy images suggest the formation of an adsorbed layer, which was further supported by chemical analysis via x-ray photoelectron spectroscopy (XPS) data for [C6mim][TfO].

friction↗

Mechanisms of Mitigating Chloride-Induced Stress Corrosion Cracking of Austenitic Steels by Laser Shock Peening

This study investigates the effect of laser shock peening (LSP) on the chloride-induced stress corrosion cracking (SCC) of 304 austenitic steels. LSP can induce a high compressive residual stress to a depth of 700 µm and plastic deformation structures of dislocations, deformation twins, and stacking faults. Constant-load SCC tests in MgCl2 solution suggested that LSP can retard the crack initiation and slow the crack growth. LSP-treated subsurface layers experience ductile fracture while the central regions exhibit intergranular SCC. The LSP-induced deformation structures may impede dislocation slips, while the LSP-induced compressive residual stress can lessen the stress intensity factor of crack tips and decrease the local stress for film rupture.

Materials Science↗

Highly quaternized polystyrene ionomers for high performance anion exchange membrane water electrolysers

Alkaline anion exchange membrane (AEM) electrolysers to produce hydrogen from water remain at an early stage of development, and their performance is far lower than that of systems based on proton exchange membranes. Here, we report an ammonium-enriched anion exchange ionomer that improves the performance of an AEM electrolyser to levels approaching that of state-of-the-art proton exchange membrane electrolysers. Using rotating-disk electrode experiments, we show that a high pH (>13) in the electrode binder is the critical factor for improving the activity of the hydrogen- and oxygen-evolution reactions in AEM electrolysers. Based on this observation, we prepared and tested several quaternized polystyrene electrode binders in an AEM electrolyser. Using the binder with the highest ionic concentration and a NiFe oxygen evolution catalyst, we demonstrated performance of 2.7 A cm -2 at 1.8 V without a corrosive circulating alkaline solution. The limited durability of the AEM electrolyser remains a challenge to be addressed in the future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Niowave Neutron Source Converter: Lead-Bismuth-Eutectic (LBE) Windowless Target Design and Evaluation

Los Alamos National Laboratory (LANL) is working with Niowave on the design and evaluation of their lead-bismuth-eutectic (LBE) windowless target (i.e., neutron source converter). Niowave plans to use 200 kW electron beam at 40 MeV beam energy to produce neutrons by photonuclear reaction with LBE. Then, the neutrons undergo fission at the surrounding uranium target assembly (UTA) to produce Molybdenum 99 (Mo-99) as a fission product, which eventually decays to Technetium-99 (Tc-99m). Tc-99m is one of important radioisotopes that is used for medical diagnostics. LANL conducted 3D multiphysics analysis for the Niowave neutron converter design and provided design assessment in thermohydraulic aspects. LANL conducted radiation transport calculations using Monte-Carlo N-Particle (MCNP) code with unstructured meshing scheme. The 3D volumetric heating profiles in the LBE and Stainless-Steel (SS) housing were imported into multiphase computational fluid dynamics (CFD) to obtain 3D temperature profiles of LBE and SS through conjugate heat transfer (CHT) analysis. The key findings are: LBE film thickness at the center of the beam is approximately 1.6 cm with a maximum LBE velocity of approximately 1.8 m/s, which is below a 2 m/s limit to avoid erosion issues on supporting structures; Heat deposition in the LBE peaks at ~1 cm depth from the LBE free-surface because of the forward interactions of electron, photon, and neutron with LBE; LBE maximum temperature is ~360 °C, which is below LBE evaporation initiative temperature, ~450 °C; LBE-SS interface temperature is ~350 °C, which is below the safety thermal limit to prevent severe corrosion on SS. The results indicate that Niowave’s neutron converter design satisfies both hydraulic and thermal criteria for safe operation. By virtue of such computational analysis, Niowave can move toward establishing an experimental setup to experimentally test their LBE neutron converter. The following sections describe the detailed work done by LANL.

43 PARTICLE ACCELERATORS↗

The impact of temperature, chlorides and sulfate-reducing bacteria on the corrosion of steel in soil

Here, this investigation aimed to study the corrosion performance of low-carbon steel in a soil environment at different temperatures. The steel specimens in the soil were treated at three temperatures: 5, 25 and 60°C. The specimens were embedded in chloride-free soil for 21 days, and then 3.5% (by weight) sodium chloride (NaCl) was added to the soil. The specimens were then kept in the chloride-contaminated soil for 54 days. The results of electrochemical experiments showed superior corrosion performance of the specimens at 60°C, which had the lowest corrosion activity, followed by the specimens at 5 and 25°C. The slow nature of the kinetics of the corrosion reactions at 5°C compared with that at ambient temperature was the reason for this improvement at 5°C. The lower number of microorganisms, including sulfate-reducing bacteria, in the soil at 60°C compared with that at the other temperatures was attributed to the lower corrosion activity of steel in the soil at 60°C compared with the corrosion activity of steel in the soil at other temperatures.

99 - GENERAL AND MISCELLANEOUS↗

Lifetime extension drop-test of real-world corroded 5 Quart Hagan nuclear material storage container

A 5Qt Hagan container with a 20-year history of nuclear material storage was challenged with three successive drop tests at a height of 3.7 meters. The total mass of the test package was 12.1 kg. The 1st and 2nd drop tests (center of gravity over the container bottom corner but 180 degrees apart on the container bottom face) passed the pre- and post- impact helium leak criterion at less than 1.00E-6 atm-cc/sec (ambient cubic centimeters per second). The 3rd and final test (center of gravity over top corner) failed with a post-impact gross leak of 1.1E-1 atmcc/sec. The RRFMC (Respirable Release Fraction Measurement Chamber) is a drop tower test system that is critical for the sustainability of the SAVY-4000™ series and Hagan-type (NFT Inc. Golden CO) nuclear material storage containers. These are the primary in-use nuclear material storage container types at the Los Alamos National Laboratory TA-55 facility. Results are presented to expand the technical knowledge basis for container lifetime, regarding actual exposure to corrosive gas species on the container inner surfaces. The primary source of general corrosion throughout the container is gaseous hydrogen chloride (HCl). This gas is generated by the degradation of the polyvinylchloride (PVC) bag-out bag. Additionally, in most cases, the nuclear material itself also releases HCl gas (due to residual chemical components associated with the material formation). The RRFMC drop tower gives the end-user the ability record and analyze high-speed video and photography and if needed aerosol mass release measurements. In this report the principal issue is the physical deformation of the 5Qt Hagan container. There were no mass release experiments of test aerosol mass in the present study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY23 Update: Aerosol Sampling for the Canister Deposition Field Demonstration

This report describes the results of preliminary testing of aerosol monitoring equipment that will be used to continuously monitor the aerosol source term for the multi-year Canister Deposition Field Demonstration (CDFD). These data are required inputs for the development and validation of models for the deposition of dust and potentially corrosive salts on the surface of spent nuclear fuel (SNF) dry storage canisters. Surface salt loads correlate with the extent of corrosion damage on a metal surface, and potentially to the likelihood and timing of initiation of stress corrosion cracks. Aerosols will be monitored at the CDFD site using three instruments. A Dekati ® ELPI+ cascade impactor will be used for real-time monitoring of aerosol particle sizes. It will also collect dust in 14 size bins on impactor targets that can be chemically analyzed to determine the soluble salts present as a function of particle size. However, this instrument can only measure dried aerosols, with a diameter of <10 µm. The second instrument is a Topas laser particle size spectrometer, which provides real-time monitoring of aerosol particle sizes up to ~40 µm in size. It monitors both the ambient (potentially deliquesced) aerosol particle size distributions required for the dust deposition models and the distributions of the equivalent dried particles, allowing correlation with the Dekati ® data. However, it does not discriminate between inert dust particles and salt aerosols, and it does not retain samples of the different particle sizes for later analysis. The third instrument that will monitor aerosols at the CDFD site is a Clean Air Status and Trends Network (CASTNET) tower, which uses a multiple canister system to collect weekly samples for analysis to total suspended aerosol particle compositions and atmospheric gas concentrations. This status report describes work in FY23 to develop the capabilities for using these tools. In two training exercises, the cascade impactor and laser particle sizer were deployed in two different testing environments, one indoor and one outdoor. For the cascade impactor, the tests provided opportunities for the operators to familiarize themselves with impactor substrate preparation, and post-test sample removal and analysis. For the laser particle sizer, the tests were used to evaluate different instrument parameters, to determine the most appropriate settings for capturing transient events. Data and samples were collected for weeks to months for each test, and the results are presented here. In addition to the preliminary testing, contracts were developed with WSP Analytical Labs for sample preparation and analysis of the cascade impactor samples. The impactor tower from outdoor test was delivered to WSP and used to train the staff there in disassembly, sample extraction, sample analysis, and tower reassembly with new target substrates. These are tasks that WSP will be performing routinely for the CDFD project. The CASTNET system cannot be purchased or tested until an actual site has been selected for the CDFD test. Work for this FY has been restricted to preparation of contracts for purchasing the CASTNET tower, and for sample analysis, once the tower is in operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Water-Fed, Photovoltaic-Driven Anion-Exchange Membrane Water Electrolysis for Solar Hydrogen Production

Direct coupled photovoltaic (PV)-electrolysis is a promising approach for low-cost hydrogen production, avoiding the need for separate electricity generation. Without solar concentration, the operating current densities of a PV-electrolyzer are small, and low capital costs are needed to reach hydrogen production cost targets (<$2/kg). Anion-exchange membrane (AEM) electrolyzers could be well-suited for this application due to their ability to use platinum group metal (PGM)-free catalysts and operate without supporting electrolytes, but a water-fed PV-AEM system has not yet been demonstrated. In this work, the performance of two AEM electrolyzer designs under pure-water, low-temperature, and diurnal-cycling conditions was evaluated. A simple PV-electrolyzer system design with direct electric coupling to a commercial 84 cm2 Si mini module and passive heating and water flow to the electrolyzer was used for on-sun testing in October 2025. The best-performing PV-AEM system achieved an average solar-to-hydrogen (STH) efficiency of 6.6% and a production rate of 15 mg/kWh/m2 of solar irradiance over 11 days. Minimal electrolyzer corrosion was observed, with no loss in efficiency over the diurnal cycles. While highlighting areas for improved electrolyzer and system design, this work is a proof of concept for distributed hydrogen production using inexpensive and abundant materials.

08 HYDROGEN↗