Search NASA⌕ Search

SEARCH · Search NASA

Results for “CT Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Dosimetric Impact of Interfraction Catheter Movement in High-Dose Rate Prostate Brachytherapy

Purpose: To evaluate the impact of interfraction catheter movement on dosimetry in prostate high-dose-rate (HDR) brachytherapy. Methods and Materials: Fifteen patients were treated with fractionated HDR brachytherapy. Implants were performed on day 1 under transrectal ultrasound guidance. A computed tomography (CT) scan was performed. Inverse planning simulated annealing was used for treatment planning. The first fraction was delivered on day 1. A cone beam CT (CBCT) was performed on day 2 before the second fraction was given. A fusion of the CBCT and CT was performed using intraprostatic gold markers as landmarks. Initial prostate and urethra contours were transferred to the CBCT images. Bladder and rectum contours were drawn, and catheters were digitized on the CBCT. The planned treatment was applied to the CBCT dataset, and dosimetry was analyzed and compared to the initial dose distribution. This process was repeated after a reoptimization was performed, using the same constraints used on day 1. Results: Mean interfraction catheter displacement was 5.1 mm. When we used the initial plan on day 2, the mean prostate V100 (volume receiving 100 Gy or more) decreased from 93.8% to 76.2% (p < 0.01). Rectal V75 went from 0.75 cm{sup 3} to 1.49 cm{sup 3} (p < 0.01). A reoptimization resulted in a mean prostate V100 of 88.1%, closer to the initial plan (p = 0.05). Mean rectal V75 was also improved with a value of 0.59 cm{sup 3}. There was no significant change in bladder and urethra dose on day 2. Conclusions: A mean interfraction catheter displacement of 5.1 mm results in a significant decrease in prostate V100 and an increase in rectum dose. A reoptimization before the second treatment improves dose distribution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluations of an adaptive planning technique incorporating dose feedback in image-guided radiotherapy of prostate cancer

Purpose: Online image guidance (IG) has been used to effectively correct the setup error and inter-fraction rigid organ motion for prostate cancer. However, planning margins are still necessary to account for uncertainties such as deformation and intra-fraction motion. The purpose of this study is to investigate the effectiveness of an adaptive planning technique incorporating offline dose feedback to manage inter-fraction motion and residuals from online correction. Methods: Repeated helical CT scans from 28 patients were included in the study. The contours of prostate and organs-at-risk (OARs) were delineated on each CT, and online IG was simulated by matching center-of-mass of prostate between treatment CTs and planning CT. A seven beam intensity modulated radiation therapy (IMRT) plan was designed for each patient on planning CT for a total of 15 fractions. Dose distribution at each fraction was evaluated based on actual contours of the target and OARs from that fraction. Cumulative dose up to each fraction was calculated by tracking each voxel based on a deformable registration algorithm. The cumulative dose was compared with the dose from initial plan. If the deviation exceeded the pre-defined threshold, such as 2% of the D{sub 99} to the prostate, an adaptive planning technique called dose compensation was invoked, in which the cumulative dose distribution was fed back to the treatment planning system and the dose deficit was made up through boost radiation in future treatment fractions. The dose compensation was achieved by IMRT inverse planning. Two weekly compensation delivery strategies were simulated: one intended to deliver the boost dose in all future fractions (schedule A) and the other in the following week only (schedule B). The D{sub 99} to prostate and generalized equivalent uniform dose (gEUD) to rectal wall and bladder were computed and compared with those without the dose compensation. Results: If only 2% underdose is allowed at the end of the treatment course, then 11 patients fail. If the same criteria is assessed at the end of each week (every five fractions), then 14 patients fail, with three patients failing the 1st or 2nd week but passing at the end. The average dose deficit from these 14 patients was 4.4%. They improved to 2% after the weekly compensation. Out of these 14 patients who needed dose compensation, ten passed the dose criterion after weekly dose compensation, three patients failed marginally, and one patient still failed the criterion significantly (10% deficit), representing 3.6% of the patient population. A more aggressive compensation frequency (every three fractions) could successfully reduce the dose deficit to the acceptable level for this patient. The average number of required dose compensation re-planning per patient was 0.82 (0.79) per patient for schedule A (B) delivery strategy. The doses to OARs were not significantly different from the online IG only plans without dose compensation. Conclusions: We have demonstrated the effectiveness of offline dose compensation technique in image-guided radiotherapy for prostate cancer. It can effectively account for residual uncertainties which cannot be corrected through online IG. Dose compensation allows further margin reduction and critical organs sparing.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-E-BRF-10: Interim Esophageal Cancer Response Assessment Via 18FDG-PET Scanning During Radiation Therapy

Purpose: Local failure occurs in a large proportion of esophageal cancer patients treated with chemoradiation. The treatment strategy for non-responders could potentially be modified if they are identified during therapy. This work investigates the utility of an interim 18FDG-PET scan acquired during the course of therapy as a predictor of pathological response post-therapy. Methods: Fifteen patients underwent 18FDG-PET scanning prior to radiation therapy (RT) and once during RT, after delivery of ∼32 Gy. The physician-contoured GTV on the planning CT scan was used to automatically segment a PET-based GTV on the pre-RT PET (GTV-pre-PET) as the volume with >40% of the maximum GTV PET SUV value. The pre- and intra-RT CTs were deformably registered to each other to transfer the GTV-pre-PET to the intra-RT PET (GTV-intra-PET). The fractional decrease in the maximum SUV, mean SUV and the SUV to the highest intensity 10% – 90% volumes from GTV-pre-PET to GTV-intra-PET were compared to pathological response assessed at the time of post-RT surgery. Results: Based on post-treatment pathology of 15 patients, 7 were classified as achieving favorable response (treatment effect grade ≤ 1) and 8 as unfavorable response (treatment effect grade > 1). Neither fractional decrease in maximum SUV nor mean SUV were significant between the favorable and unfavorable groups. However, the fractional decrease in SUV20% (SUV to the highest 20% volume) was significant (p = 0.02), with an area under the Receiver Operating Characteristics (ROC) curve of 0.84. An optimal cutoff value of 0.46 for this metric was able to distinguish between the two groups with 71% sensitivity (favorable) and 88% specificity (unfavorable). Conclusion: The fractional decrease in SUV to the volume with highest 20% intensity from pre- to intra-RT 18FDG-PET imaging may be used to distinguish between favorable and unfavorable responders with high sensitivity and specificity.

60 APPLIED LIFE SCIENCES↗

TU-F-CAMPUS-J-03: Evaluation of a New GE Device-Less Cine 4D-CT

Purpose: Standard cine 4D-CT (S-4DCT) is the cine CT scan of the thorax followed by image sorting with the respiratory signal recorded by the RPM. Although the feasibility of cine 4D-CT without RPM or device-less 4DCT (DL-4DCT) has been reported in a laboratory setting, the only commercial implementation of DL-4DCT was made recently by GE based on the measurements of the lung, body and air area and density. We report the initial results of this new DL-4DCT on its determination of gross tumor volume (GTV). Methods: 30 stereotactic body radiation therapy (SBRT) patients with NSCLC were included in the study. All patients received the S-4DCT for their treatment planning. Their cine CT data without the respiratory signal from RPM were submitted to the DL-4DCT. The DL-4DCT image quality was assessed in reference to S-4DCT. Using maximum intensity projection (MIP) images, the GTVs of the S-4DCT and DL-4DCT were compared on a subset of 9 patients whose tumors in the low density lung regions could be contoured using a region growing algorithm in MIM without contouring bias from the user. A lower threshold of −424 HU was used for all patients and other algorithm parameters were held constant for each patient. Results: The DL-4DCT was able to produce the 4DCT images on 29 out of the 30 SBRT cases. One case failed due to the enhanced calcification surrounding both the breast implants. The GTVs determined on the 9 patients with DL-4DCT were 4.2 ± 4.8% smaller than the GTVs with S-4DCT. However, this was statistically insignificant (p=0.15). The Dice similarity coefficients were 95.1 ± 1.8%. The image quality of DL-4DCT and S-4DCT was similar on the 29 cases. Conclusion: The first commercial DL-4DCT was promising in generating 4D-CT images without a respiratory monitoring device in this preliminary study of 30 patients.

60 APPLIED LIFE SCIENCES↗

Automated aortic calcium scoring on low-dose chest computed tomography

Purpose: Thoracic computed tomography (CT) scans provide information about cardiovascular risk status. These scans are non-ECG synchronized, thus precise quantification of coronary calcifications is difficult. Aortic calcium scoring is less sensitive to cardiac motion, so it is an alternative to coronary calcium scoring as an indicator of cardiovascular risk. The authors developed and evaluated a computer-aided system for automatic detection and quantification of aortic calcifications in low-dose noncontrast-enhanced chest CT. Methods: The system was trained and tested on scans from participants of a lung cancer screening trial. A total of 433 low-dose, non-ECG-synchronized, noncontrast-enhanced 16 detector row examinations of the chest was randomly divided into 340 training and 93 test data sets. A first observer manually identified aortic calcifications on training and test scans. A second observer did the same on the test scans only. First, a multiatlas-based segmentation method was developed to delineate the aorta. Segmented volume was thresholded and potential calcifications (candidate objects) were extracted by three-dimensional connected component labeling. Due to image resolution and noise, in rare cases extracted candidate objects were connected to the spine. They were separated into a part outside and parts inside the aorta, and only the latter was further analyzed. All candidate objects were represented by 63 features describing their size, position, and texture. Subsequently, a two-stage classification with a selection of features and k-nearest neighbor classifiers was performed. Based on the detected aortic calcifications, total calcium volume score was determined for each subject. Results: The computer system correctly detected, on the average, 945 mm{sup 3} out of 965 mm{sup 3} (97.9%) calcified plaque volume in the aorta with an average of 64 mm{sup 3} of false positive volume per scan. Spearman rank correlation coefficient was {rho}=0.960 between the system and the first observer compared to {rho}=0.961 between the two observers. Conclusions: Automatic calcium scoring in the aorta thus appears feasible with good correlation between manual and automatic scoring.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of the dosimetric impact of interfractional anatomical variations on prostate proton therapy using daily in-room CT images

Purpose: To quantify interfractional anatomical variations and their dosimetric impact during the course of fractionated proton therapy (PT) of prostate cancer and to assess the robustness of the current treatment planning techniques. Methods: Simulation and daily in-room CT scans from ten prostate carcinoma patients were analyzed. PT treatment plans (78 Gy in 39 fractions of 2 Gy) were created on the simulation CT, delivering 25 fractions to PTV1 (expanded from prostate and seminal vesicles), followed by 14 boost fractions to PTV2 (expanded from prostate). Plans were subsequently applied to daily CT, with beams aligned to the prostate center in the sagittal plane. For five patients having a sufficiently large daily imaging volume, structure contours were manually drawn, and plans were evaluated for all CT sets. For the other five patients, the plans were evaluated for six selected fractions. The daily CT was matched to the simulation CT through deformable registration. The registration accuracy was validated for each fraction, and the three patients with a large number of accurately registered fractions were used for dose accumulation. Results: In individual fractions, the coverage of the prostate, seminal vesicles, and PTV1 was generally maintained at the corresponding prescription dose. For PTV2, the volume covered by the fractional prescription dose of 2 Gy (i.e., V2) was, on average, reduced by less than 3% compared to the simulation plan. Among the 225 (39 x 5 + 6 x 5) fractions examined, 15 showed a V2 reduction larger than 5%, of which ten were caused by a large variation in rectal gas, and five were due to a prostate shift in the craniocaudal direction. The fractional dose to the anterior rectal wall was found to increase for one patient who had large rectal gas volume in 25 of the 39 fractions, and another who experienced significant prostate volume reduction during the treatment. The fractional bladder dose generally increased with decreasing fullness. In the total accumulated dose for the three patients after excluding a few fractions with inaccurate registration due to a large amount of rectal gas (a condition inconsistent with RTOG protocol), 98.5%, 96.6%, and 98.2% of the PTV2 received the prescription dose of 78 Gy. The V75 and V70 of the anterior rectal wall and bladder both remained within tolerance. Conclusions: The results confirm that the PT planning techniques and dose constraints used at our institution ensure that target coverage to the prescription dose is maintained in the presence of interfractional anatomical variations. Dose coverage in individual fractions can be compromised, and normal tissue dose increased, due to deviations in the bladder and rectal volume compared to the simulation plans or progressive changes in the prostate volume during the treatment. Deviations from the plan can be reduced with efforts aimed at maintaining consistent daily patient anatomy.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-E-13: Design and Fabrication of Gynacological Brachytherapy Shielding & Non Shielding Applicators Using Indigenously Developed 3D Printing Machine

Purpose: In this innovative work we have developed Gynecological Brachytherapy shielding & Non Shielding Applicators and compared with the commercially available applicators by using the indigenously developed 3D Printing machine. Methods: We have successfully indigenously developed the 3D printing machine. Which contain the 3 dimensional motion platform, Heater unit, base plate, ect… To fabricate the Gynecological Brachytherapy shielding & non shielding applicators the 3D design were developed in the computer as virtual design. This virtual design is made in a CAD computer file using a 3D modeling program. Separate programme for the shielding & non shielding applicators. We have also provided the extra catheter insert provision in the applicator for the multiple catheter. The DICOM file of the applicator were then converted to stereo Lithography file for the 3D printer. The shielding & Non Shielding Applicators were printed on a indigenously developed 3D printer material. The same dimensions were used to develop the applicators in the acrylic material also for the comparative study. A CT scan was performed to establish an infill-density calibration curve as well as characterize the quality of the print such as uniformity and the infill pattern. To commission the process, basic CT and dose properties of the printing materials were measured in photon beams and compared against water and soft tissue. Applicator were then scanned to confirm the placement of multiple catheter position. Finally dose distributions with rescanned CTs were compared with those computer-generated applicators. Results: The doses measured from the ion Chamber and X-Omat film test were within 2%. The shielded applicator reduce the rectal dose comparatively with the non shielded applicator. Conclusion: As of submission 3 unique cylinders have been designed, printed, and tested dosimetrically. A standardizable workflow for commissioning custom 3D printed applicators was codified and will be reported.

60 APPLIED LIFE SCIENCES↗

SU-E-T-470: Importance of HU-Mass Density Calibration Technique in Proton Pencil Beam Dose Calculation

Purpose: Stoichiometric calibration of Hounsfield Units (HUs) for conversion to proton relative stopping powers (RStPs) is vital for accurate dose calculation in proton therapy. However proton dose distributions are not only dependent on RStP, but also on relative scattering power (RScP) of patient tissues. RScP is approximated from material density but a stoichiometric calibration of HU-density tables is commonly neglected. The purpose of this work was to quantify the difference in calculated dose of a commercial TPS when using HU-density tables based on tissue substitute materials and stoichiometric calibrated ICRU tissues. Methods: Two HU-density calibration tables were generated based on scans of the CIRS electron density phantom. The first table was based directly on measured HU and manufacturer quoted density of tissue substitute materials. The second was based on the same CT scan of the CIRS phantom followed by a stoichiometric calibration of ICRU44 tissue materials. The research version of Pinnacle{sup 3} proton therapy was used to compute dose in a patient CT data set utilizing both HU-density tables. Results: The two HU-density tables showed significant differences for bone tissues; the difference increasing with increasing HU. Differences in density calibration table translated to a difference in calculated RScP of −2.5% for ICRU skeletal muscle and 9.2% for ICRU femur. Dose-volume histogram analysis of a parallel opposed proton therapy prostate plan showed that the difference in calculated dose was negligible when using the two different HU-density calibration tables. Conclusion: The impact of HU-density calibration technique on proton therapy dose calculation was assessed. While differences were found in the calculated RScP of bony tissues, the difference in dose distribution for realistic treatment scenarios was found to be insignificant.

60 APPLIED LIFE SCIENCES↗

Reconstituted Three-Dimensional Interactive Imaging

A method combines two-dimensional images, enhancing the images as well as rendering a 3D, enhanced, interactive computer image or visual model. Any advanced compiler can be used in conjunction with any graphics library package for this method, which is intended to take digitized images and virtually stack them so that they can be interactively viewed as a set of slices. This innovation can take multiple image sources (film or digital) and create a "transparent" image with higher densities in the image being less transparent. The images are then stacked such that an apparent 3D object is created in virtual space for interactive review of the set of images. This innovation can be used with any application where 3D images are taken as slices of a larger object. These could include machines, materials for inspection, geological objects, or human scanning. Illuminous values were stacked into planes with different transparency levels of tissues. These transparency levels can use multiple energy levels, such as density of CT scans or radioactive density. A desktop computer with enough video memory to produce the image is capable of this work. The memory changes with the size and resolution of the desired images to be stacked and viewed.

Hamilton, Joseph↗

MO-FG-CAMPUS-TeP1-03: Pre-Treatment Surface Imaging Based Collision Detection

Purpose: Modern radiotherapy increasingly employs large immobilization devices, gantry attachments, and couch rotations for treatments. All of which raise the risk of collisions between the patient and the gantry / couch. Collision detection is often achieved by manually checking each couch position in the treatment room and sometimes results in extraneous imaging if collisions are detected after image based setup has begun. In the interest of improving efficiency and avoiding extra imaging, we explore the use of a surface imaging based collision detection model. Methods: Surfaces acquired from AlignRT (VisionRT, London, UK) were transferred in wavefront format to a custom Matlab (Mathworks, Natick, MA) software package (CCHECK). Computed tomography (CT) scans acquired at the same time were sent to CCHECK in DICOM format. In CCHECK, binary maps of the surfaces were created and overlaid on the CT images based on the fixed relationship of the AlignRT and CT coordinate systems. Isocenters were added through a graphical user interface (GUI). CCHECK then compares the inputted surfaces to a model of the linear accelerator (linac) to check for collisions at defined gantry and couch positions. Note, CCHECK may be used with or without a CT. Results: The nominal surface image field of view is 650 mm × 900 mm, with variance based on patient position and size. The accuracy of collision detections is primarily based on the linac model and the surface mapping process. The current linac model and mapping process yield detection accuracies on the order of 5 mm, assuming no change in patient posture between surface acquisition and treatment. Conclusions: CCHECK provides a non-ionizing method to check for collisions without the patient in the treatment room. Collision detection accuracy may be improved with more robust linac modeling. Additional gantry attachments (e.g. conical collimators) can be easily added to the model.

60 APPLIED LIFE SCIENCES↗

Strategies for Online Organ Motion Correction for Intensity-Modulated Radiotherapy of Prostate Cancer: Prostate, Rectum, and Bladder Dose Effects

Purpose: To quantify and evaluate the accumulated prostate, rectum, and bladder dose for several strategies including rotational organ motion correction for intensity-modulated radiotherapy (IMRT) of prostate cancer using realistic organ motion data. Methods and Materials: Repeat computed tomography (CT) scans of 19 prostate patients were used. Per patient, two IMRT plans with different uniform margins were created. To quantify prostate and seminal vesicle motion, repeat CT clinical target volumes (CTVs) were matched onto the planning CTV using deformable registration. Four different strategies, from online setup to full motion correction, were simulated. Rotations were corrected for using gantry and collimator angle adjustments. Prostate, rectum, and bladder doses were accumulated for each patient, plan, and strategy. Minimum CTV dose (D{sub min}), rectum equivalent uniform dose (EUD, n = 0.13), and bladder surface receiving >=78 Gy (S78), were calculated. Results: With online CTV translation correction, a 7-mm margin was sufficient (i.e., D{sub min} >= 95% of the prescribed dose for all patients). A 4-mm margin required additional rotational correction. Margin reduction lowered the rectum EUD(n = 0.13) by approx2.6 Gy, and the bladder S78 by approx1.9%. Conclusions: With online correction of both translations and rotations, a 4-mm margin was sufficient for 15 of 19 patients, whereas the remaining four patients had an underdosed CTV volume <1%. Margin reduction combined with online corrections resulted in a similar or lower dose to the rectum and bladder. The more advanced the correction strategy, the better the planned and accumulated dose agreed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is There an Advantage in Designing Adapted, Patient-Specific PTV Margins in Intensity Modulated Proton Beam Therapy for Prostate Cancer?

Purpose: To investigate robust margin strategies in intensity modulated proton therapy to account for interfractional organ motion in prostate cancer. Methods and Materials: For 9 patients, one planning computed tomography (CT) scan and daily and weekly cone beam CTs (CBCTs) were acquired and coregistered. The following planning target volume (PTV) approaches were investigated: a clinical target volume (CTV) delineated on the planning CT (CTV{sub ct}) plus 10-mm margin (PTV{sub 10mm}); a reduced PTV (PTV{sub Red}): CTV{sub ct} plus 5 mm in the left-right (LR) and anterior-posterior (AP) directions and 8 mm in the inferior-superior (IS) directions; and a PTV{sub Hull} method: the sum of CTV{sub ct} and CTVs from 5 CBCTs from the first week plus 3 mm in the LR and IS directions and 5 mm in the AP direction. For each approach, separate plans were calculated using a spot-scanning technique with 2 lateral fields. Results: Each approach achieved excellent target coverage. Differences were observed in volume receiving 98% of the prescribed dose (V{sub 98%}) where PTV{sub Hull} and PTV{sub Red} results were superior to the PTV{sub 10mm} concept. The PTV{sub Hull} approach was more robust to organ motion. The V{sub 98%} for CTVs was 99.7%, whereas for PTV{sub Red} and PTV{sub 10mm} plans, V{sub 98%} was 98% and 96.1%, respectively. Doses to organs at risk were higher for PTV{sub Hull} and PTV{sub 10mm} plans than for PTV{sub Red}, but only differences between PTV{sub 10mm} and PTV{sub Red} were significant. Conclusions: In terms of organ sparing, the PTV{sub 10mm} method was inferior but not significantly different from the PTV{sub Red} and PTV{sub Hull} approaches. PTV{sub Hull} was most insensitive to target motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-D-BRA-05: Pseudo In Vivo Patient Dosimetry Using a 3D-Printed Patient-Specific Phantom

Purpose: To test the feasibility of using 3D-printed patient-specific phantoms for intensity-modulated radiation therapy (IMRT) quality assurance (QA). Methods: We created a patient-specific whole-head phantom using a 3D printer. The printer data file was created from high-resolution DICOM computed tomography (CT) images of 3-year old child treated at our institution for medulloblastoma. A custom-modified extruder system was used to create tissue-equivalent materials. For the printing process, the Hounsfield Units from the CT images were converted to proportional volumetric densities. A 5-field IMRT plan was created from the patient CT and delivered to the 3D- phantom. Dose was measured by an ion chamber placed through the eye. The ion chamber was placed at the posterior edge of the planning target volume in a high dose gradient region. CT scans of the patient and 3D-phantom were fused by using commercial treatment planning software (TPS). The patient’s plan was calculated on the phantom CT images. The ion chamber’s active volume was delineated in the TPS; dose per field and total dose were obtained. Measured and calculated doses were compared. Results: The 3D-phantom dimensions and tissue densities were in good agreement with the patient. However, because of a printing error, there was a large discrepancy in the density in the frontal cortex. The calculated and measured treatment plan doses were 1.74 Gy and 1.72 Gy, respectively. For individual fields, the absolute dose difference between measured and calculated values was on average 3.50%. Conclusion: This study demonstrated the feasibility of using 3D-printed patient-specific phantoms for IMRT QA. Such phantoms would be particularly advantageous for complex IMRT treatment plans featuring high dose gradients and/or for anatomical sites with high variation in tissue densities. Our preliminary findings are promising. We anticipate that, once the printing process is further refined, the agreement between measured and calculated doses will improve.

60 APPLIED LIFE SCIENCES↗

A virtual simulator designed for collision prevention in proton therapy

Purpose: In proton therapy, collisions between the patient and nozzle potentially occur because of the large nozzle structure and efforts to minimize the air gap. Thus, software was developed to predict such collisions between the nozzle and patient using treatment virtual simulation. Methods: Three-dimensional (3D) modeling of a gantry inner-floor, nozzle, and robotic-couch was performed using SolidWorks based on the manufacturer’s machine data. To obtain patient body information, a 3D-scanner was utilized right before CT scanning. Using the acquired images, a 3D-image of the patient’s body contour was reconstructed. The accuracy of the image was confirmed against the CT image of a humanoid phantom. The machine components and the virtual patient were combined on the treatment-room coordinate system, resulting in a virtual simulator. The simulator simulated the motion of its components such as rotation and translation of the gantry, nozzle, and couch in real scale. A collision, if any, was examined both in static and dynamic modes. The static mode assessed collisions only at fixed positions of the machine’s components, while the dynamic mode operated any time a component was in motion. A collision was identified if any voxels of two components, e.g., the nozzle and the patient or couch, overlapped when calculating volume locations. The event and collision point were visualized, and collision volumes were reported. Results: All components were successfully assembled, and the motions were accurately controlled. The 3D-shape of the phantom agreed with CT images within a deviation of 2 mm. Collision situations were simulated within minutes, and the results were displayed and reported. Conclusions: The developed software will be useful in improving patient safety and clinical efficiency of proton therapy.

60 APPLIED LIFE SCIENCES↗

Use of Computed Tomography for Characterizing Materials Grown Terrestrially and in Microgravity

Computed Tomography (CT) has advanced considerably since being responsible for such dramatic advances in diagnostics within the medical field. It has become a major tool in non destructive evaluation (NDE), and is used in many fields as diverse as coal-mining to metal solidification to examination of rock cores. A review of industrial applications has been written by Dennis. It is only recently that the technique has been seriously used to determine composition through precise measurement of density. While such applications are restricted to cases when there is no ambiguity in the relationship of composition to density. Thus alloy solid solutions lend themselves to compositional analysis provided there is a large change in density with composition. The technique is most useful when rapid non-destructive evaluation is needed. Such cases will occur with samples returning from the International Space Station (ISS) when knowledge of the results could affect future strategies for processing of on-board samples. Experiments from those Principal Investigators (PI) that are most likely to benefit from early CT scanning are discussed. With a dearth of samples, the major emphasis in the first part of this project has been on preparing suitable standards, optimizing the CT technique for these applications, and using the CT system to determine density variations with temperature. An interesting application of CT has been in the examination of meteorites, which can be classified as space-grown materials and will certainly have solidified in a low gravity environment.

Gillies, Donald C.↗

SU-C-213-04: Application of Depth Sensing and 3D-Printing Technique for Total Body Irradiation (TBI) Patient Measurement and Treatment Planning

Purpose: To develop and validate an innovative method of using depth sensing cameras and 3D printing techniques for Total Body Irradiation (TBI) treatment planning and compensator fabrication. Methods: A tablet with motion tracking cameras and integrated depth sensing was used to scan a RANDOTM phantom arranged in a TBI treatment booth to detect and store the 3D surface in a point cloud (PC) format. The accuracy of the detected surface was evaluated by comparison to extracted measurements from CT scan images. The thickness, source to surface distance and off-axis distance of the phantom at different body section was measured for TBI treatment planning. A 2D map containing a detailed compensator design was calculated to achieve uniform dose distribution throughout the phantom. The compensator was fabricated using a 3D printer, silicone molding and tungsten powder. In vivo dosimetry measurements were performed using optically stimulated luminescent detectors (OSLDs). Results: The whole scan of the anthropomorphic phantom took approximately 30 seconds. The mean error for thickness measurements at each section of phantom compare to CT was 0.44 ± 0.268 cm. These errors resulted in approximately 2% dose error calculation and 0.4 mm tungsten thickness deviation for the compensator design. The accuracy of 3D compensator printing was within 0.2 mm. In vivo measurements for an end-to-end test showed the overall dose difference was within 3%. Conclusion: Motion cameras and depth sensing techniques proved to be an accurate and efficient tool for TBI patient measurement and treatment planning. 3D printing technique improved the efficiency and accuracy of the compensator production and ensured a more accurate treatment delivery.

60 APPLIED LIFE SCIENCES↗

Dosimetric Analysis of Organs at Risk During Expiratory Gating in Stereotactic Body Radiation Therapy for Pancreatic Cancer

Purpose: To determine how the respiratory phase impacts dose to normal organs during stereotactic body radiation therapy (SBRT) for pancreatic cancer. Methods and Materials: Eighteen consecutive patients with locally advanced, unresectable pancreatic adenocarcinoma treated with SBRT were included in this study. On the treatment planning 4-dimensional computed tomography (CT) scan, the planning target volume (PTV), defined as the gross tumor volume plus 3-mm margin, the duodenum, and the stomach were contoured on the end-expiration (CT{sub exp}) and end-inspiration (CT{sub insp}) phases for each patient. A separate treatment plan was constructed for both phases with the dose prescription of 33 Gy in 5 fractions with 95% coverage of the PTV by the 100% isodose line. The dose-volume histogram (DVH) endpoints, volume of duodenum that received 20 Gy (V{sub 20}), V{sub 25}, and V{sub 30} and maximum dose to 5 cc of contoured organ (D{sub 5cc}), D{sub 1cc}, and D{sub 0.1cc}, were evaluated. Results: Dosimetric parameters for the duodenum, including V{sub 25}, V{sub 30}, D{sub 1cc}, and D{sub 0.1cc} improved by planning on the CT{sub exp} compared to those on the CT{sub insp}. There was a statistically significant overlap of the PTV with the duodenum but not the stomach during the CT{sub insp} compared to the CT{sub exp} (0.38 ± 0.17 cc vs 0.01 ± 0.01 cc, P=.048). A larger expansion of the PTV, in accordance with a Danish phase 2 trial, showed even more overlapping volume of duodenum on the CT{sub insp} compared to that on the CT{sub exp} (5.5 ± 0.9 cc vs 3.0 ± 0.8 cc, P=.0003) but no statistical difference for any stomach dosimetric DVH parameter. Conclusions: Dose to the duodenum was higher when treating on the inspiratory than on the expiratory phase. These data suggest that expiratory gating may be preferable to inspiratory breath-hold and free breathing strategies for minimizing risk of toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Variation in the Definition of Clinical Target Volumes for Pelvic Nodal Conformal Radiation Therapy for Prostate Cancer

Purpose: We conducted a comparative study of clinical target volume (CTV) definition of pelvic lymph nodes by multiple genitourinary (GU) radiation oncologists looking at the levels of discrepancies amongst this group. Methods and Materials: Pelvic computed tomography (CT) scans from 2 men were distributed to 14 Radiation Therapy Oncology Group GU radiation oncologists with instructions to define CTVs for the iliac and presacral lymph nodes. The CT data with contours were then returned for analysis. In addition, a questionnaire was completed that described the physicians' method for target volume definition. Results: Significant variation in the definition of the iliac and presacral CTVs was seen among the physicians. The minimum, maximum, mean (SD) iliac volumes (mL) were 81.8, 876.6, 337.6 {+-} 203 for case 1 and 60.3, 627.7, 251.8 {+-} 159.3 for case 2. The volume of 100% agreement was 30.6 and 17.4 for case 1 and 2 and the volume of the union of all contours was 1,012.0 and 807.4 for case 1 and 2, respectively. The overall agreement was judged to be moderate in both cases (kappa = 0.53 (p < 0.0001) and kappa = 0.48 (p < 0.0001). There was no volume of 100% agreement for either of the two presacral volumes. These variations were confirmed in the responses to the associated questionnaire. Conclusions: Significant disagreement exists in the definition of the CTV for pelvic nodal radiation therapy among GU radiation oncology specialists. A consensus needs to be developed so as to accurately assess the merit and safety of such treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗