Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cell Count”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Effect of temperature on capacity fade in silicon-rich anodes

Coin half-cells containing 80 wt% silicon electrodes are assembled and cycled at the similar to C/10 rate in the temperature range of 25-55 degrees C. To the best of our knowledge, this is the first time that the effect of temperature is reported for such high-silicon-containing cells. Two different electrolytes are used in this study, a baseline electrolyte and the baseline electrolyte +10 wt% fluoroethylene carbonate (FEC). Analysis of the capacity vs. cycle count data by curve fitting reveals that the addition of FEC markedly affects the capacity loss mechanism. Without FEC, the kinetic rate law for the capacity loss mechanism can be described as the sum of two logistic growth models. With the addition of FEC, the rate law depends on ln(t). Clearly, the addition of FEC has a profound effect on the mechanism of capacity loss. Interestingly, X-ray photoelectron spectroscopy (XPS) shows that the composition of the solid electrolyte interphase (SEI) layer changes markedly from mostly organic to mostly inorganic in the presence of FEC and how it varies at the different temperatures tested, especially in the absence of FEC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid direct methods for enumeration of specific, active bacteria in water and biofilms

Conventional methods for detecting indicator and pathogenic bacteria in water may underestimate the actual population due to sublethal environmental injury, inability of the target bacteria to take up nutrients and other physiological factors which reduce bacterial culturability. Rapid and direct methods are needed to more accurately detect and enumerate active bacteria. Such a methodological advance would provide greater sensitivity in assessing the microbiological safety of water and food. The principle goal of this presentation is to describe novel approaches we have formulated for the rapid and simultaneous detection of bacteria plus the determination of their physiological activity in water and other environmental samples. The present version of our method involves the concentration of organisms by membrane filtration or immunomagnetic separation and combines an intracellular fluorochrome (CTC) for assessment of respiratory activity plus fluorescent-labelled antibody detection of specific bacteria. This approach has also been successfully used to demonstrate spatial and temporal heterogeneities of physiological activities in biofilms when coupled with cryosectioning. Candidate physiological stains include those capable of determining respiratory activity, membrane potential, membrane integrity, growth rate and cellular enzymatic activities. Results obtained thus far indicate that immunomagnetic separation can provide a high degree of sensitivity in the recovery of seeded target bacteria (Escherichia coli O157:H7) in water and hamburger. The captured and stained target bacteria are then enumerated by either conventional fluorescence microscopy or ChemScan(R), a new instrument that is very sensitive and rapid. The ChemScan(R) laser scanning instrument (Chemunex, Paris, France) provides the detection of individual fluorescently labelled bacterial cells using three emission channels in less than 5 min. A high degree of correlation has been demonstrated between results obtained with the ChemScan and traditional plate counts of mixed natural bacterial populations in water. The continuing evolution of these methods will be valuable in the rapid and accurate analysis of environmental samples.

Review, Tutorial↗

Transcript and blood-microbiome analysis towards a blood diagnostic tool for goats affected by Haemonchus contortus

The Alpine goat (Capra aegagrus hircus) is parasitized by the barber pole worm (Haemonchus contortus). Hematological parameters from transcript and metagenome analysis in the host are reflective of infestation. We explored comparisons between blood samples of control, infected, infected zoledronic acid-treated, and infected antibody (anti-γδ T cells) treated wethers under controlled conditions. Seven days post-inoculation (dpi), we identified 7,627 transcripts associated with the different treatment types. Microbiome measurements at 7 dpi revealed fewer raw read counts across all treatments and a less diverse microbial flora than at 21 dpi. This study identifies treatment specific transcripts and an increase in microflora abundance and diversity as wethers age. Further, F/B ratio reflect health, based on depression or elevation above thresholds defined by the baseline of non-infected controls. Forty Alpine wethers were studied where blood samples were collected from five goats in four treatment groups on 7 dpi and 21 dpi. Transcript and microbiome profiles were obtained using the Partek Flow (St. Louis, Missouri, USA) software suites pipelines. Inflammation comparisons were based on the Firmicutes/Bacteriodetes ratios that are calculated as well as the reduction of microbial diversity.

60 APPLIED LIFE SCIENCES↗

Radiation Dosimetry via Automated Fluorescence Microscopy

A developmental instrument for assessment of radiation-induced damage in human lymphocytes includes an automated fluorescence microscope equipped with a one or more chargecoupled- device (CCD) video camera(s) and circuitry to digitize the video output. The microscope is also equipped with a three-axis translation stage that includes a rotation stage, and a rotary tray that holds as many as thirty specimen slides. The figure depicts one version of the instrument. Once the slides have been prepared and loaded into the tray, the instrument can operate unattended. A computer controls the operation of the stage, tray, and microscope, and processes the digital fluorescence-image data to recognize and count chromosomes that have been broken, presumably by radiation. The design and method of operation of the instrument exploit fluorescence in situ hybridization (FISH) of metaphase chromosome spreads, which is a technique that has been found to be valuable for monitoring the radiation dose to circulating lymphocytes. In the specific FISH protocol used to prepare specimens for this instrument, metaphase lymphocyte cultures are chosen for high mitotic index and highly condensed chromosomes, then several of the largest chromosomes are labeled with three of four differently colored whole-chromosome-staining dyes. The three dyes, which are used both individually and in various combinations, are fluorescein isothiocyanate (FITC), Texas Red (or equivalent), and Cy5 (or equivalent); The fourth dye 4',6-diamidino- 2-phenylindole (DAPI) is used as a counterstain. Under control by the computer, the microscope is automatically focused on the cells and each slide is scanned while the computer analyzes the DAPI-fluorescence images to find the metaphases. Each metaphase field is recentered in the field of view and refocused. Then a four-color image (more precisely, a set of images of the same view in the fluorescent colors of the four dyes) is acquired. By use of pattern-recognition software developed specifically for this instrument, the images in the various colors are processed to recognize the metaphases and count the chromosome fragments of each color within the metaphases. The intermediate results are then further processed to estimate the proportion of cells that have suffered genetic damage. The prototype instrument scans at an average areal rate of 4.7 mm2/h in unattended operation, finding about 14 metaphases per hour. The false-alarm rate is typically less than 3 percent, and the metaphase-miss rate has been estimated to be less than 5 percent. The counts of chromosomes and fragments thereof are 50 to 70 percent accurate.

Castleman, Kenneth R.↗

AS101-Loaded PLGA–PEG Nanoparticles for Autoimmune Regulation and Chemosensitization

The in vivo delivery of therapeutic nanoparticles (NPs) represents a potentially powerful tool that can significantly alter the biological effects of pharmaceutically active compounds. Here, we report on sensitization of tumors to chemotherapy by ammonium trichloro(dioxoethyleneo, o’)tellurate (AS101) encapsulated in NPs, termed AS101-NPs, developed as a composite with the biocompatible and biodegradable copolymer of poly(D,L-lactic-co-glycolic acid)- block-poly(ethylene glycol) (PLGA- b -PEG). AS101 is a potent immunomodulating agent (both in vitro and in vivo) currently undergoing phase II clinical trials for anti-tumor activity and sensitization of tumors to chemotherapy. Approaches that can control the pharmacokinetic parameters to regulate its clearance from the administered drug delivery system and minimize side effects are of prodigious importance. A strategy to synthesize AS101-NPs by nanoprecipitation is presented, along with their physical characterization. The influence of AS101 encapsulation on its properties was evaluated in vivo. The AS101-NPs demonstrated significantly enhanced peritoneal macrophage count compared with AS101 administered in vivo at conventional dosage in mouse models. Moreover, AS101 inhibited B16 melanoma lung metastasis in mice when given intraperitoneally, before or after tumor cell inoculation. A bellshaped dose-response was observed. The frequency of AS101 administration appears to be an important factor for achieving optimal antimetastatic effect.

60 APPLIED LIFE SCIENCES↗

The effects of space flight on polymorphonuclear leukocyte response experiment MA-032

In a series of studies performed at intervals from 30 day before flight to 30 days after recovery, blood samples were obtained from the three astronauts of the Apollo Soyuz Test Project and from eight control subjects. To determine the effects of space flight on polymorphonuclear leukocytes, tests were performed on blood samples obtained as quickly as possible after splashdown and on the day following recovery. The astronauts' inhalation of propellant gases and the inception of corticosteroid therapy 1 day after recovery provided an additional opportunity to investigate the possible effects of these factors on leukocyte function. Data were obtained during each time period on the total leukocyte count, differential count, leukocyte adhesion, leukocyte migration and chemotaxis, phagocytosis, and histochemical staining for leukocyte acid and alkaline phosphatase. These observations present a variety of in vitro correlates to white blood cell function within the body. Taken together, they serve as a reasonable approximation of the effects of space flight on leukocyte function.

Martin, R. R.↗

Microcoupon Assay Of Adhesion And Growth Of Bacterial Films

Microbiological assay technique facilitates determination of some characteristics of sessile bacteria like those that attach to and coat interior walls of water-purification systems. Biofilms cause sickness and interfere with purification process. Technique enables direct measurement of rate of attachment of bacterial cells, their metabolism, and effects of chemicals on them. Used to quantify effects of both bactericides and growth-stimulating agents and in place of older standard plate-count and tube-dilution techniques.

Pierson, Duane L.↗

Extreme background rejection techniques for the ELROI satellite license plate

The extremely low-resource optical identifier (ELROI) is a concept for an autonomous, low-power optical “license plate” that can be attached to anything that goes into space. ELROI uses short, omnidirectional flashes of laser light to encode a unique ID number that can be read by a small ground telescope using a photon-counting sensor and innovative extreme background-rejection techniques. ELROI is smaller and lighter than a typical radio beacon, low-power enough to run on its own small solar cell, and can safely operate for the entire orbital lifetime of a satellite or debris object. The concept has been validated in ground tests, and orbital prototypes are scheduled for launch in 2018 and beyond. In this paper, we focus on the details of the encoding scheme and data analysis that allow a milliwatt optical signal to be read from orbit. We describe the techniques of extreme background-rejection needed to achieve this, including spectral filtering and temporal filtering using a period- and phase-recovery algorithm, and discuss the requirements for an error-correcting code to encode the ID number. Worked examples with both simulated and experimental (long-range ground test) data illustrate the methods used. Finally, we present these techniques to describe a new optical communication concept, and to encourage others to consider observing and analyzing our upcoming test flights.

42 ENGINEERING↗

Pulmonary toxicity of simulated lunar and Martian dusts in mice: II. Biomarkers of acute responses after intratracheal instillation

Volcanic ashes from Arizona and Hawaii, with chemical and mineral properties similar to those of lunar and Martian soils, respectively, are used by the National Aeronautics and Space Administration (NASA) to simulate lunar and Martian environments for instrument tests. NASA needs toxicity data on these volcanic soils to assess health risks from potential exposures of workers in facilities where these soil simulants are used. In this study we investigated the acute effects of lunar soil simulant (LSS) and Martian soil simulant (MSS), as a complement to a histopathological study assessing their subchronic effects (Lam et al., 2002). Fine dust of LSS, MSS, TiO(2), or quartz suspended in saline was intratracheally instilled into C57Bl/6J mice (4/group) in single doses of 0.1 mg/mouse or 1 mg/mouse. The mice were euthanized 4 or 24 h after the dust treatment, and bronchoalveolar lavage fluid (BALF) was obtained. Statistically significant lower cell viability and higher total protein concentration in the BALF were seen only in mice treated with the high dose of quartz for 4 h and with the high dose of MSS or quartz for 24 h, compared to mice treated only with saline. A significant increase in the percentage of neutrophils was not observed with any dust-treated group at 4 h after the instillation, but was observed after 24 h in all the dust-treated groups. This observation indicates that these dusts were not acutely toxic and the effects were gradual; it took some time for neutrophils to be recruited into and accumulate significantly in the lung. A statistically significant increase in apoptosis of lavaged macrophages from mice 4 h after treatment was found only in the high-dose silica group. The overall results of this study on the acute effects of these dusts in the lung indicate that LSS is slightly more toxic than TiO(2), and that MSS is comparable to quartz. These results were consistent with the subchronic histopathological findings in that the order of severity of lung toxicity was TiO(2) < LSS < MSS < quartz.

Non-programmatic↗

Effect of weightlessness conditions on the somatic embryogenesis in the culture of carrot cells

A carrot cell culture seeded in Petri dishes in the United States and transported to the USSR was subjected to weightlessness for 20 days during the flight of Kosmos 782. The controls were cultures placed on a centrifuge (1 g) inside the satellite and cultures left on ground in the U.S.S.R. and the United States. A count of structures in the dishes after the flight showed that the number of developing embryonic structures and the extent of their differentiation in weightlessness did not reliably differ from the number and extent of differentiation in structures developed on the ground. Structures with long roots developed in weightlessness. Analysis of the root zones showed that these roots differed by the increased size of the zone of differentiated cells. The increased size of the zones of differentiated cells can indicate earlier development of embryonic structures.

Butenko, R. G.↗

In-Operando XRD Study of the Effects of Water Vapor on Phase Formation in LSM/YSZ SOFC Cathodes

Here, in-operando XRD was conducted on anode supported SOFC button cells with LSM-YSZ cathodes operated at varying cathode air compositions under constant current conditions for over 1000 h. 1-hour XRD scans were continuously collected throughout the entire operation duration. By taking the sum of measured intensities from all of the collected patterns, the resulting cumulative XRD count times allowed the identification of minor phases present at concentrations as low as <0.1 wt%. In dry air with no contaminants, the cathode exhibited improving power output during the first couple of hundred hours, followed by stable operation. The effect of 3% H 2 O + 12% CO 2 on the LSM-YSZ cathode was very similar to the effect of 3% H 2 O alone, exhibiting performance degradation. Increasing contaminants in the cathode air were found to decrease the performance of the cells. In-operando XRD discovered an increase in MnO concentration and decrease in La 2 O 3 . A gradual expansion of the LSM lattice resulting from loss of Sr or O was discovered in the LSM/YSZ cathodes tested in humid cathode air. The inverse relationship between the unit cell volume and operating voltage suggests a possible correlation between Sr segregation and performance degradation in the LSM/YSZ cathodes.

25 ENERGY STORAGE↗

Radiological characterization of high Cs-137 waste items at LANL combining Cs-137 NDA results and acceptable process knowledge - 15592

Radiological characterization is an important component to disposition and disposal of radioactive waste at the Los Alamos National Laboratory. Gamma and neutron based non-destructive assay systems are available at LANL's TA-54 Area G for radiological characterization and are generally very effective in quantifying the transuranic radionuclide concentration required for a TRU or low level waste disposition determination. This is routinely performed by scaling some nuclides to direct assay results using acceptable process knowledge scaling from a directly measured key TRU nuclide, e.g., for gamma systems using a standard isotopic distribution to determine the amount of Pu-240 associated with a measured value of Pu-239. However, for two groups of LANL waste items that have high levels of Cs-137, these non-destructive assay systems were unable to make a standard TRU/LLW determination. Therefore, it was necessary to apply an extension of the typical scaling technique that keyed in on the direct Cs-137 gamma assay result to effectively characterize these waste items for TRU processing or LLW disposition. Two basic types of waste packages contained the high Cs-137 waste requiring special scaling: drums and boxes. The drums included 55-gallon, 85-gallon and 110-gallon volume sizes and the boxes included a corrugated metal box, a Standard Waste Box, and several overpack boxes containing oversized waste. All of these items contained radioactive waste generated from operations at the Chemistry and Metallurgical Research facility at LANL that included hot cell, metallographic sectioning and maintenance activities. All of the drums as well as the CMB, SWB and one oversized item in a plywood box were located above-ground at LANL's TA-54 Area G, while five of the oversized items were hot cell liners in metal boxes stored below-ground in shafts. All of the items were measured in the 2013-2014 time period at TA-54 Area G with LANL NDA systems. Most of the items were counted with LLW certified far-field gamma spectroscopy systems employing portable far-field HPGe detectors and carts and some of the items were counted on WIPP certified gamma only or gamma with neutron NDA systems. In all cases Cs-137 was quantified directly with a gamma measurement but the key TRU nuclides were not detectable. Thus, for each waste item AK/PK was studied and scaling factors to Cs-137 were established and applied to provide a comprehensive radiological characterization. A total of 49 waste items were successfully characterized as LLW based on this technique. The above ground waste items were dispositioned and disposed of at an offsite LLW repository and the below ground boxes were left in place as LLW in the TA-54 Area G shafts. This NDA with scaling application has proved effective and defensible in these high Cs-137 cases at LANL and will continue to be used as applicable and appropriate for future waste characterization at LANL. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of epifluorescent viable bacterial count methods

Two methods, the 2-(4-Iodophenyl) 3-(4-nitrophenyl) 5-phenyltetrazolium chloride (INT) method and the direct viable count (DVC), were tested and compared for their efficiency for the determination of the viability of bacterial populations. Use of the INT method results in the formation of a dark spot within each respiring cell. The DVC method results in elongation or swelling of growing cells that are rendered incapable of cell division. Although both methods are subjective and can result in false positive results, the DVC method is best suited to analysis of waters in which the number of different types of organisms present in the same sample is assumed to be small, such as processed waters. The advantages and disadvantages of each method are discussed.

Rodgers, E. B.↗

Chemical Kinetic Method for Active-Site Quantification in Fe-N-C Catalysts and Correlation with Molecular Probe and Spectroscopic Site-Counting Methods

Mononuclear Fe ions ligated by nitrogen (FeN x ) dispersed on nitrogen-doped carbon (Fe-N-C) serve as active centers for electrocatalytic O 2 reduction and thermocatalytic aerobic oxidations. Despite their promise as replacements for precious metals in a variety of practical applications, such as fuel cells, the discovery of new Fe-N-C catalysts has relied primarily on empirical approaches. In this context, the development of quantitative structure–reactivity relationships and benchmarking of catalysts prepared by different synthetic routes and by different laboratories would be facilitated by the broader adoption of methods to quantify atomically dispersed FeN x active centers. In the present study, we develop a kinetic probe reaction method that uses the aerobic oxidation of a model hydroquinone substrate to quantify the density of FeN x centers in Fe- N-C catalysts. The kinetic method is compared with low-temperature Mössbauer spectroscopy, CO pulse chemisorption, and electrochemical reductive stripping of NO derived from NO 2 – on a suite of Fe-N-C catalysts prepared by diverse routes and featuring either the exclusive presence of Fe as FeN x sites or the coexistence of aggregated Fe species in addition to FeN x . The FeN x site densities derived from the kinetic method correlate well with those obtained from CO pulse chemisorption and Mössbauer spectroscopy. The broad survey of Fe-N-C materials also reveals the presence of outliers and challenges associated with each site quantification approach. Furthermore, the kinetic method developed here does not require pretreatments that may alter active-site distributions nor specialized equipment beyond reaction vessels and analytical instrumentation (e.g., NMR).

36 MATERIALS SCIENCE↗

Method of detecting and counting bacteria in body fluids

A novel method is reported for determining bacterial levels in urine samples, which method depends on the quantitative determination of bacterial adenosine triphosphate (ATP) in the presence of non-bacterial ATP. After the removal of non-bacterial ATP, the bacterial ATP is released by cell rupture and is measured by an enzymatic bioluminescent assay using an enzyme obtained from the firefly.

Chappelle, E. W.↗

Collision Tracking in OpenMC: Methods and Applications in Neutron Noise, Neutron Imaging, Time-of-Flight, and Multiplicity Counting

We present the development and application of a collision tracking feature within the OpenMC Monte Carlo particle transport code, designed for diverse applications such as neutron spectroscopy, scatter camera system, neutron noise, and multiplicity counting simulations. This feature enables the tracking of individual particle collisions, with potential applications in nuclear nonproliferation, reactor physics, and nuclear security. Additionally, the feature holds potential for the calibration of neutron detectors, specifically in converting light output into energy deposited within the detectors. The implementation consists of a set of filters—such as reaction type, energy, cell, and material—that constrain the set of collisions that are tracked, extensions to the Python API to enable simple input specification, and support for writing either OpenMC’s native HDF5-based format or the Monte Carlo particle list format. This feature was added to the official OpenMC release in version 0.15.3. In this work, the feature will be applied to showcase scenarios such as time-of-flight simulations, scatter-camera imaging for neutron source localization, neutron-noise analysis to extract integral kinetic parameters such as the prompt decay constant α, and multiplicity counting to estimate the mass of special nuclear materials. Ultimately, this feature aims to expand the application scope of open-source Monte Carlo particle transport codes such as OpenMC.

Monte Carlo code↗

The Distribution of Non-Volatile Elements on Mars: Mars Odyssey GRS Results

The major scientific objective of the Gamma-Ray Spectrometer (GRS) on the 2001 Mars Odyssey Mission is to determine the distribution of elements in the near-surface of Mars. Mars Odyssey has been in its mapping orbit since February, 2002, and the GRS boom, which removes the instrument from the gamma-ray background of the spacecraft, was erected in June, 2002. In the 580 days since boom erection, we have accumulated 453 days of mapping data. The difference is due mostly to two times when Odyssey went into safe mode and the instrument warmed up forcing us to anneal out radiation damage that manifests itself after warming. Other data losses are due to simple transmitter data gaps and to intense solar particle events. The data from the GRS is statistical in nature. We have a very low count rate and a very low signal-to-noise ratio. With the exception of K, the most easily mapped elements have a signal/noise ratio on the order of 0.1 (0.5 for K) and the counting rates are on the order of 0.3 to 0.7 counts/min (4 cpm for K). In order to map the distribution of an element, we have to divide the total signal from Mars up into many cells that define the map s spatial resolution (unless the statistics are good enough that the intrinsic spatial resolution of the instrument, about 550 km diameter, dominates). The data for several elements have now achieved a statistical precision that permits us to make meaningful maps.

Boynton, W.↗