514 records · Page 29

Experimental Studies of Elementary Particle Interactions at High Energies

This is the final report of a program of research on "Experimental Studies of Elementary Particle Interactions at High Energies'' of the High Energy Physics (HEP) group of The Rockefeller University. The research was carried out using the Collider Detector at Fermilab (CDF) and the Compact Muon Solenoid (CMS) detector at the Large Hadron Collider (LHC) at CERN. Three faculty members, two research associates, and two postdoctoral associates participated in this project. At CDF, we studied proton-antiproton collisions at an energy of 1.96 TeV. We focused on diffractive interactions, in which the colliding antiproton loses a small fraction of its momentum, typically less than 1%, while the proton is excited into a high mass state retaining its quantum numbers. The study of such collisions provides insight into the nature of the diffractive exchange, conventionally referred to as Pomeron exchange. In studies of W and Z production, we found results that point to a QCD-based interpretation of the diffractive exchange, as predicted in a data-driven phenomenology developed within the Rockefeller HEP group. At CMS, we worked on diffraction, supersymmetry (SUSY), dark matter, large extra dimensions, and statistical applications to data analysis projects. In diffraction, we extended our CDF studies to higher energies working on two fronts: measurement of the single/double diffraction and of the rapidity gap cross sections at 7 TeV, and development of a simulation of diffractive processes along the lines of our successful model used at CDF. Working with the PYTHIA8 Monte Carlo simulation authors, we implemented our model as a PYTHIA8-MBR option in PYTHIA8 and used it in our data analysis. Preliminary results indicate good agreement. We searched for SUSY by measuring parameters in the Constrained Minimal Supersymmetric extension of the Standard Model (CMSSM) and found results which, combined with other experimental constraints and theoretical considerations, indicate that the CMSSM is not a viable model. Expressing our results in terms of simple topologies, we exclude squark masses below 0.75 TeV and gluino masses below 1.1 TeV. Astrophysical measurements suggest that about 80% of the matter density of the Universe is non-luminous. One of the theories on dark matter attributes it to Weakly Interacting Massive Particles (WIMPs). We searched for WIMPs in 7 TeV and 8 TeV collisions at CMS and set limits on WIMP production rates, which are competitive and complementary to those of direct detection experiments. Searching for monojets (events with only one jet), which in a popular model could be produced by a jet paired by a gravitino that escapes into extra dimensions, we significantly improved the previously set limit. Our results have been used to set limits on Higgs decay to invisible particles and on production of top squarks in compressed SUSY scenarios. Statistics. We computed Bayesian reference priors for several types of measurement and used them in the analysis of CMS data; investigated the applicability of bootstrap methods to HEP measurements; studied several issues associated with simple-versus-simple hypothesis testing and applied the resulting methods to the measurement of some properties of the top quark and Higgs boson.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electronics Upgrades to the Green is Clean Phoswich Detector Systems and Programmatic Implementation at LANL - Phase II Completion - 18403

Los Alamos National Laboratory (LANL) radiological facilities produce low-density room trash that, in many cases, is not contaminated with radioactivity. It has been estimated that 50 to 90% of low-density room trash is free of radioactive contamination and eligible for inclusion in LANL's Green is Clean (GIC) program. The GIC program is a verification program for non-regulated waste from radiation controlled areas that has been actively segregated as nonradioactive through the use of the waste generator's acceptable knowledge. The GIC program has employed two large area Phoswich gamma ray detector systems (HERCULES and ZEUS) to verify that GIC candidate low-density waste contains no radioactivity above background. The large area (127 cm{sup 2}) Phoswich detectors consist of a thin NaI front crystal (3 mm thick) that is optically coupled to a thick CsI back crystal (50 mm thick). The scintillation properties of the two crystals are different enough to allow the system's electronic components to identify the origin of any pulse. The original systems utilize Nuclear Instrumentation Module (NIM) electronics to process the detector signals. The electronics currently in use by the systems are out of date and some components are no longer manufactured. In 2015, phase I upgrades to the GIC detector systems were completed. Phase I objectives included identifying more modern commercially available electronics that could replace the NIM electronics. A pulse shape discriminator (PSD) module, the Digital Gamma Finder (DGF) Pixie-4 made by XIA LLC, that fits in a compact National Instruments{sup TM} PXI chassis was identified to replace the majority of the original NIM bin electronics - a single Pixie-4 module replaces four NIM amplifiers and four NIM pulse shape analyzers (PSAs). Another phase I objective was to show that that new PSD could separate out the NaI and CsI detector signals in a manner equivalent to or better than the NIM electronics. Proof of concept was achieved in 2015 when a prototype upgrade system on ZEUS was built and tested and gating parameter settings were determined that successfully separated the NaI and CsI signals. Phase II required establishing a LabVIEW software interface with Pixie-4 electronics in lieu of the manufacturer provided Pixie-4 software called the Pixie Viewer. In addition, phase II included 1) final optimization of the gating parameters on the prototype Pixie-4 ZEUS system, 2) finalizing Requirements, Design and Test Plan documents, 3) LabVIEW software interface quality assurance (QA) testing, 4) setting up the HERCULES system with the Pixie-4 upgrade electronics, 5) check source and background calibration of both systems, 6) absolute efficiency determination on both systems and 7) procedure revisions and implementation of both systems into routine operations. In 2017 phase II was completed including the preparation of detailed Requirements, Design and Test Plan documents. The LabVIEW interface software that communicates and controls the Pixie-4 has been completed, merged with the preexisting LabVIEW operations software and fully tested. Gating parameter optimization, configuration of HERCULES with the Pixie-4 electronics, check source and background calibrations and absolute efficiency determinations have all been performed - quantitative results are presented in the full paper. For performance validation, comparison measurements of actual GIC bags on both the HERCULES system using the old NIM Bin electronics and the ZEUS system using the upgraded Pixie-4 electronics have been done and evaluated. Finally, procedure revisions and implementation of both systems into routine operations is currently in process and planned to be complete by the end of calendar year 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Active Measurement of Plasma Parameters in Over-Dense MFE Reactor Plasma Using High Frequency Beat-Wave Resonantly Generated Thermal Bernstein Waves

UC Davis was funded to explore the combination of beat-wave excitation and laser scattering to make completely non-invasive determination of local plasma conditions. This involves the use of two high frequency mm-wave sources of differing frequencies (the pump waves) to excite plasma waves at the difference of the frequencies, which is known as the beat frequency. The difference frequency or the frequency of the beat wave is chosen so that we produce plasma waves whose fluctuating electron density is a sensitive function of plasma parameters at the location where the source waves overlap. This fluctuation can be detected from outside the plasma, by measuring the deflection of a probe beam directed at the overlap region between the two pump waves (i.e., collective scattering). This work is an extension of mm-wave frequencies of a 10 GHz beat-wave experiment conducted on the DDT toroidal device (see Fig. 1) in a magnetized plasma where the excited Langmuir wave is replaced by the magnetized upper hybrid wave. Here, two high power (> 1 kW) ~94 GHz pump sources will be employed to match the upper hybrid resonance. The primary envisioned experiment is to drive the electron Bernstein wave (EBW) in the interior of a magnetized plasma. The EBW is a hot-plasma electrostatic wave, which cannot propagate in vacuum. Roots of the EBW dispersion relation occur at frequencies slightly higher than harmonics of the electron cyclotron frequency. Use of the EBW has particular advantages for measuring plasma magnetic field in plasmas with relatively high density and low magnetic field, as is the case in spherical tokamaks. This is the “over dense” condition of future efficient high beta magnetic confinement fusion reactors such as the spherical tokamak (STs). The overarching goal of the proposed project is to demonstrate beat wave EBW excitation in low density and temperature parameters that are directly scalable to over-dense spherical tokamaks such as NSTX or MAST, where measurement of magnetic field by electron cyclotron emission (ECE) is experimentally complex, and requires models of plasma profiles in order to interpret results. In such experiments, availability of point measurements of magnetic field strength provided by a beat-wave diagnostic would serve as a powerful independent check on the ECE results, serving to validate the assumed profiles and wave-propagation models used. The first step was to assemble/modify the target chamber in which the beat-wave plasma experiments will take place. Here, the target chamber of the CTIX compact-toroid (spheromak) injector was chosen. At the time that the proposal was submitted, the aim was to conduct the experiments in the CTIX experimental facilities located at the Livermore campus of UC Davis using microwave/mm-wave equipment brought from the main campus., However, by the time DoE funds for this project were awarded, the CTIX experimental facilities located at the Livermore campus of UC Davis were in the process of being shut down due to the closure of the Livermore campus by Lawrence Livermore National Laboratory (LLNL). Consequently, the equipment needed for this project was crated up and shipped from Livermore to Davis as part of the laboratory shutdown after space on campus was secured and College of Engineering approval secured. Once it arrived in Davis on December 20, 2018, work on the project began in earnest with the initial efforts directed toward developing a new plasma target source. Because of the shutdown of the CTIX facility, the scope of the project thus had to be reduced due to the abbreviated amount of time allocated to the project once the shutdown/move had been completed. Chamber modifications have been completed, including the fabrication and installation of a 38 GHz interferometer, as described in Sec. 3. The thermionic plasma source has been tested and characterized. The magnetic field required for the EBW experiments will be generated by permanent magnets mounted on plates positioned above and below the chamber. Magnetic simulations have been performed, and show that a 3-ring magnet arrangement on each plate, with a plate separation of 50 cm, is required to achieve the ~100 G uniform magnetic field in the interaction region that we feel is necessary to ensure good EBW coupling. We proved unable to successfully revive either of Prof. Luhmann’s two high power (≥20 kW) 94 GHz millimeter-wave sources after their extended time in storage and decided to postpone further efforts and concentrate on slightly lower power sources. Consequently, we were successful in reviving a ~2 kW extended klystron amplifier (EIK), which together with a ~2 kW extended interaction oscillator (EIO) will provide the two pump sources required for the project. Safe operation of the EIO requires extensive modifications to one of Prof. Luhmann’s pulse modulators - these modulator modifications are ongoing, which has unfortunately delayed the planned beat-wave experiments. Details of this work are provided in Sec. 3. Even though project funding has now ended, we still plan to proceed to complete the EIO pulse modulator modifications, install the two ~94 GHz pump wave sources on the target chamber, and conduct unmagnetized tests of the beat-wave concept which involve coupling to unmagnetized electron plasma waves rather than magnetized EBWs. Should these experiments prove successful, we plan to submit a follow-up proposal for additional funding which would allow us to undertake the magnetized EBW experiments.

42 ENGINEERING↗

Tritium Transport Modeling at the Pore Scale in Ceramic Breeder Materials Using TMAP8

Fusion reactors depend on the blanket material to breed and release tritium at the same rate or faster than it is consumed by the fusion reaction. Cellular ceramic breeders (CCBs) are dense materials that can maintain a high tritium breeding ratio while promoting tritium release because of highly connected pores. Assessing the tritium breeding capabilities of these materials requires a combination of extensive experimental and modeling efforts. In this work, we develop and calibrate a multiphysics model of tritium transport. This novel model accounts for ceramic and pore diffusion, trapping and detrapping, and several surface reactions at the pore surface. We perform a sensitivity analysis and calibrate the model by comparing its predictions against experimental measurements of deuterium absorption. The calibrated model is then used to model tritium absorption in samples with different pore microstructures to investigate the effect of pore interconnectivity on tritium absorption. The model is part of the development of the multiscale, multiphysics framework for tritium transport [i.e., the Tritium Migration Analysis Program (TMAP8)], which is itself built on top of the finite-element multiphysics framework multiphysics object-oriented simulation environment (MOOSE). This study demonstrates some of TMAP8’s capabilities and is the first step toward assessing the tritium breeding capabilities of ceramic breeder material designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estimation of transport parameters of phenolic compounds and inorganic contaminants through composite landfill liners using one-dimensional mass transport model

Highlights: > We conduct 1D advection-dispersion modeling to estimate transport parameters. > We examine fourteen phenolic compounds and three inorganic contaminants. > 2-MP, 2,4-DCP, 2,6-DCP, 2,4,5-TCP, 2,3,4,6-TeCP have the highest coefficients. > Dispersion coefficients of Cu are determined to be higher than Zn and Fe. > Transport of phenolics can be prevented by zeolite and bentonite in landfill liners. - Abstract: One-dimensional (1D) advection-dispersion transport modeling was conducted as a conceptual approach for the estimation of the transport parameters of fourteen different phenolic compounds (phenol, 2-CP, 2-MP, 3-MP, 4-MP, 2-NP, 4-NP, 2,4-DNP, 2,4-DCP, 2,6-DCP, 2,4,5-TCP, 2,4,6-TCP, 2,3,4,6-TeCP, PCP) and three different inorganic contaminants (Cu, Zn, Fe) migrating downward through the several liner systems. Four identical pilot-scale landfill reactors (0.25 m{sup 3}) with different composite liners (R1: 0.10 + 0.10 m of compacted clay liner (CCL), L{sub e} = 0.20 m, k{sub e} = 1 x 10{sup -8} m/s, R2: 0.002-m-thick damaged high-density polyethylene (HDPE) geomembrane overlying 0.10 + 0.10 m of CCL, L{sub e} = 0.20 m, k{sub e} = 1 x 10{sup -8} m/s, R3: 0.002-m-thick damaged HDPE geomembrane overlying a 0.02-m-thick bentonite layer encapsulated between 0.10 + 0.10 m CCL, L{sub e} = 0.22 m, k{sub e} = 1 x 10{sup -8} m/s, R4: 0.002-m-thick damaged HDPE geomembrane overlying a 0.02-m-thick zeolite layer encapsulated between 0.10 + 0.10 m CCL, L{sub e} = 0.22 m, k{sub e} = 4.24 x 10{sup -7} m/s) were simultaneously run for a period of about 540 days to investigate the nature of diffusive and advective transport of the selected organic and inorganic contaminants. The results of 1D transport model showed that the highest molecular diffusion coefficients, ranging from 4.77 x 10{sup -10} to 10.67 x 10{sup -10} m{sup 2}/s, were estimated for phenol (R4), 2-MP (R1), 2,4-DNP (R2), 2,4-DCP (R1), 2,6-DCP (R2), 2,4,5-TCP (R2) and 2,3,4,6-TeCP (R1). For all reactors, dispersion coefficients of Cu, ranging from 3.47 x 10{sup -6} m{sup 2}/s to 5.37 x 10{sup -2} m{sup 2}/s, was determined to be higher than others obtained for Zn and Fe. Average molecular diffusion coefficients of phenolic compounds were estimated to be about 5.64 x 10{sup -10} m{sup 2}/s, 5.37 x 10{sup -10} m{sup 2}/s, 2.69 x 10{sup -10} m{sup 2}/s and 3.29 x 10{sup -10} m{sup 2}/s for R1, R2, R3 and R4 systems, respectively. The findings of this study clearly indicated that about 35-50% of transport of phenolic compounds to the groundwater is believed to be prevented with the use of zeolite and bentonite materials in landfill liner systems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design of top covers supporting aerobic in situ stabilization of old landfills - An experimental simulation in lysimeters

Highlights: Black-Right-Pointing-Pointer Tested engineered covers as surrogate to gas extraction during and after in situ aeration. Black-Right-Pointing-Pointer Examined how covers influence gas emissions, water balance and leachate generation. Black-Right-Pointing-Pointer Investigated effect of top covers on air-distribution in waste mass during aeration. Black-Right-Pointing-Pointer We suggest criteria and cover design to meet the demands during and after aeration. Black-Right-Pointing-Pointer Such cover systems may offer greenhouse gas emission reduction also after active aeration. - Abstract: Landfill aeration by means of low pressure air injection is a promising tool to reduce long term emissions from organic waste fractions through accelerated biological stabilization. Top covers that enhance methane oxidation could provide a simple and economic way to mitigate residual greenhouse gas emissions from in situ aerated landfills, and may replace off-gas extraction and treatment, particularly at smaller and older sites. In this respect the installation of a landfill cover system adjusted to the forced-aerated landfill body is of great significance. Investigations into large scale lysimeters (2 Multiplication-Sign 2 Multiplication-Sign 3 m) under field conditions have been carried out using different top covers including compost materials and natural soils as a surrogate to gas extraction during active low pressure aeration. In the present study, the emission behaviour as well as the water balance performance of the lysimeters has been investigated, both prior to and during the first months of in situ aeration. Results reveal that mature sewage sludge compost (SSC) placed in one lysimeter exhibits in principle optimal ambient conditions for methanotrophic bacteria to enhance methane oxidation. Under laboratory conditions the mature compost mitigated CH{sub 4} loadings up to 300 l CH{sub 4}/m{sup 2} d. In addition, the compost material provided high air permeability even at 100% water holding capacity (WHC). In contrast, the more cohesive, mineral soil cover was expected to cause a notably uniform distribution of the injected air within the waste layer. Laboratory results also revealed sufficient air permeability of the soil materials (TS-F and SS-Z) placed in lysimeter C. However, at higher compaction density SS-Z became impermeable at 100% WHC. Methane emissions from the reference lysimeter with the smaller substrate cover (12-52 g CH{sub 4}/m{sup 2} d) were significantly higher than fluxes from the other lysimeters (0-19 g CH{sub 4}/m{sup 2} d) during in situ aeration. Regarding water balance, lysimeters covered with compost and compost-sand mixture, showed the lowest leachate rate (18-26% of the precipitation) due to the high water holding capacity and more favourable plant growth conditions compared to the lysimeters with mineral, more cohesive, soil covers (27-45% of the precipitation). On the basis of these results, the authors suggest a layered top cover system using both compost material as well as mineral soil in order to support active low-pressure aeration. Conventional soil materials with lower permeability may be used on top of the landfill body for a more uniform aeration of the waste due to an increased resistance to vertical gas flow. A compost cover may be built on top of the soil cover underlain by a gas distribution layer to improve methane oxidation rates and minimise water infiltration. By planting vegetation with a high transpiration rate, the leachate amount emanating from the landfill could be further minimised. The suggested design may be particularly suitable in combination with intermittent in situ aeration, in the later stage of an aeration measure, or at very small sites and shallow deposits. The top cover system could further regulate water infiltration into the landfill and mitigate residual CH{sub 4} emissions, even beyond the time of active aeration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validation Data Acquisition in HTTF during PCC Events

A validation experimental campaign was conducted in an Integral Effect Test (IET) facility of High Temperature Gas Reactors (HTGR), the High-Temperature Test Facility (HTTF) at Oregon State University (OSU). The HTTF simulates Depressurized and Pressurized Conduction Cooldowns (DCC and PCC). This campaign required the development of a new laser spectroscopic diagnostic to measure velocity in the challenging conditions of the HTTF: low speed (~1 m/s) gas flows at HTGR prototypical temperature and 1/10th pressure. This was a collaborative effort between co-PIs at The George Washington University (GW), Oregon State University (OSU), and NASA Langley Research Center. The main accomplishments of this project include the record for dynamic range for velocimetry, highest accuracy obtained with this technique, successful deployment in an IET leading to new validation matrix for CFD. These are detailed below and in manuscript appended to this executive summary. For this project, we introduced a new class of laser spectroscopic diagnostics to Thermal-Hydraulics to measure velocity of gases; furthermore, the diagnostic was demonstrated in-situ in an IET during DCC events. In such scenarios, particles used in mainstream techniques, like Particle Image Velocimetry (PIV) are not appropriate as they settle down too rapidly and also contaminate the experimental facility. Molecular tracers stay mixed within the working gas and can seed the flow in a technique called Molecular Tagging Velocimetry (MTV). In MTV a molecular tracer is photo-dissociated by a first (write) laser into radicals or molecules. The pattern created by the write laser is then interrogated with planar laser-induced fluorescence (PLIF), the read pulse(s), which are recorded with a camera. The pattern is probed and matched at two times (interval or probe time, dt), resulting in a time-of-flight velocimetry technique. This project demonstrated a new application range for MTV in gases. MTV has been extensively used for high-speed gas dynamics: molecules do not suffer from inertia associated with particles in regions of high accelerations (such as shock waves). For high-speed flows, the probe time is on the order of 0.1-10 µs. In time-of-flight techniques, the velocity is reconstructed from the recorded displacement, dx, between time interval dt: U = dx/dt. To first order, the resolution of the pattern matching is typically a (fixed) fraction of a pixel; therefore the resolution of the velocity measurement increases with dx and, for a given flow velocity, dt. For the low-speed flows of interest here, this requires long probe time, and therefore finding tracers that are stable for a long time. After an extensive literature survey we identified 6 tracers that would be suitable. We also worked with Spectra Physics to design a custom laser system that is flexible enough to probe these various tracers. The final instrument is made of 4 lasers that are integrated into a compact and movable cart to facilitate the deployment of the instrument off-site. One unique aspect of the laser system is the tunable dye laser (needed to do PLIF of the radicals). By being pumped by two Nd:YAG lasers, this laser is able to provide two pulses with any probe time (dt) for wavelengths between 200 and 900 nm with a linewidth of 3 pm. Accommodating the dual-pulse capability required customizing the pump lasers and the dye laser, making this system unique. Additionally, a custom UV-intensified CCD camera capable of frame-straddling and exposure time as short as 10 ns was acquired. More than two-third of the instrument cost (~$200k) was covered by a cost sharing from the PI’s startup funds. Of the 6 potential tracers identified, two were tested extensively (H2O and N2O) at high-temperature and elevated pressure at GW prior to conducting the tests at OSU. For both tracers, an Ar-F laser (193 nm, 10 ns, 10 mJ/pulse) photo-dissociates trace amounts (0.1 – 5% molar fraction) of the gases into OH and NO. OH is probed at 281.905 nm and NO at 226.186 nm (4-30mJ, 10 ns pulse). NO is very stable in inert environment and we could reconstruct velocities precisely with probe delay times as long at 40 ms, compared to 2 ms for OH, resulting in increased precision. Therefore, for the tests in the HTTF, N2O was selected as the final tracer and its optimal concentration was determined to be 0.5% molar. In the GW laboratory, we obtained a velocity measurement precision of 4 mm/s at conditions mimicking the HTTF tests. We also demonstrated the benefit of molecular tracers over particles and the flexibility of our instrument by continuously measuring velocity from 1000 to 0.1 m/s in a blow down test. This represents a dynamic range on velocity of 80 dB, which is unprecedented for velocimetry! Once the diagnostic was optimized, two two-week campaigns were conducted in the HTTF. This experimental campaign required numerous practical solutions to successfully and rapidly deploy this very sensitive table-top diagnostic in-situ. This was accomplished thanks to very extensive planning from all parties involved in the project. Due to constraints on availability of the HTTF, only adiabatic DCC tests were conducted. Specifically, the velocity was measured at the exit of the hot leg into the Reactor Cavity Simulation Tank (RCST). We were able to record the gas velocity associated with the air ingress for long times (up to one hour). Depending on the initial conditions (density of the gases in the Reactor Pressure Vessel and the RCST) the lock exchange lasted 30-60 s past the valve openings. Large vortices were identified within the shear layer at the interface of the cross flow. These vortices are an indication of shear-driven instability between the counter streams of different density. After the lock-exchange, a small residual flow was still present and its strength decayed exponentially. It finds its source in a buoyancy difference between the gases in both vessels due to the mixing and diffusion of the gases in the cross-over duct and the RPV lower plenum. We did not expect to capture this part of the transient, which would have been less significant (if not negligible) in the presence of a heated core; the precision of our measurement in the HTTF was 6 mm/s, which exceeded our expectations for such a complex test! Using commercial software (Fluent) we simulated the experiment with Computational Fluid Dynamic (CFD) using Reynolds Averaged Navier-Stokes (RANS) turbulence models. We were not able to accurately reproduce the shear layer instability, mixing, and diffusion captured in our experimental data, even with large 3D meshes (>10 M points). We attributed this to the inadequacy of the RANS models for the flow of interest: our experimental Reynolds number was too low and was outside the applicability range of the RANS models. Instead, we should have employed CFD with less modeling, such as Large Eddy (LES) or even Direct Numerical (DNS) simulations. Unfortunately, we did not have the computational resources to do so. Finally, it should be noted that this experimental technique holds great promises for measuring velocity in thermalhydraulics. MTV has an application domain (highlighted in the narrative) that is complimentary to more established (and simpler) techniques, such as PIV. It has attracted the attention of several thermalhydraulics researchers and sponsors to measure velocity in harsh environments. The spectroscopic nature of this technique also enables to expand it to measure temperature and concentration simultaneously to velocity. In lieu of a narrative, 4 detailed journal publications are appended to this executive summary to describe the various development and accomplishments during this project. They include 2 published manuscripts (Experiments in Fluids and Measurement Science and Technology), and two invited contributions following the NURETH-17 conference (Nuclear Science and Technology). Our current Nuclear Engineering and Design draft is not included at this time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Constraints on the Physical Properties of GW190814 through Simulations Based on DECam Follow-up Observations by the Dark Energy Survey

On 2019 August 14, the LIGO and Virgo Collaborations detected gravitational waves from a black hole and a 2.6 solar mass compact object, possibly the first neutron star–black hole merger. In search of an optical counterpart, the Dark Energy Survey (DES) obtained deep imaging of the entire 90% confidence level localization area with Blanco/DECam 0, 1, 2, 3, 6, and 16 nights after the merger. Objects with varying brightness were detected by the DES Pipeline, and we systematically reduced the candidate counterparts through catalog matching, light-curve properties, host-galaxy photometric redshifts, Southern Astrophysical Research spectroscopic follow-up observations, and machine-learning-based photometric classification. All candidates were rejected as counterparts to the merger. To quantify the sensitivity of our search, we applied our selection criteria to full light-curve simulations of supernovae and kilonovae as they would appear in the DECam observations. Because the source class of the merger was uncertain, we utilized an agnostic, three-component kilonova model based on tidally disrupted neutron star (NS) ejecta properties to quantify our detection efficiency of a counterpart if the merger included an NS. We find that, if a kilonova occurred during this merger, configurations where the ejected matter is greater than 0.07 solar masses, has lanthanide abundance less than 10 -8.56 , and has a velocity between 0.18c and 0.21c are disfavored at the 2σ level. Furthermore, we estimate that our background reduction methods are capable of associating gravitational wave signals with a detected electromagnetic counterpart at the 4σ level in 95% of future follow-up observations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiological Shielding Design for the Neutron Backscattering Spectrometer EMU

In this paper we present modelling and design of compact radiation shielding required for operation of the EMU instrument, located at Australia's OPAL nuclear reactor. The acceptance criteria for the shielding design were (i) safety - dose rate ≤ 3 μSv/h at external surfaces of the instrument's experimental area, (ii) floor load limit < 20 tons/m{sup 2}, (iii) low cost and (iv) for maintenance purposes 'easy access' to components of the instruments. The EMU instrument is a cold neutron backscattering spectrometer designed to measure inelastic neutron scattering. Its distinctive feature is that it has a tight elastic energy transfer resolution, of about 1 μeV. The instrument provides unique opportunities to study diffusion in complex materials, e.g. water molecules in confinement, polymers or biological molecules, particularly in the Asia-Oceania region. EMU is the first instrument located on the CG3 neutron beam line of the OPAL Neutron Guide Hall (NGH). A pre-existing evacuated neutron guide of dimensions 200 mm (height) x 50 mm (width) feeds into the shared EMU/KOOKABURRA pre-monochromator bunker shielding assembly, and its bottom cross section will be intercepted ∼200 mm further in air by the highly orientated pyrolytic graphite (HOPG) EMU pre-monochromator (take-off angles from 125.4 deg. to 148 deg.). The bunker shielding assembly for EMU also contains a beryllium filter and Focusing Guide Section D (FGD, 170 mm (height) x 50 mm (width)). To accommodate the range of take-off angles Pb cylindrical shielding blocks of radius 140 mm and 500 mm height have been designed. These blocks will be located at the section of the bunker where the neutron beam will exit towards the experimental area and they will reside on top of a hollow steel base (sides 10 mm thick), on which they move by sliding and are integrated with the tertiary shutter. The experimental area is enclosed by a concrete wall of 2.5 m height and 300 mm thickness, shared with the KOOKABURRA instrument, Gyprock Plasterboard panels with viewing windows, a wall from the Out-of-Pile Bunker and the CG3 shielding. The neutron beam enters the experimental area via the tertiary shutter, into the Focusing Guide Section C (FGC), which has an entrance guide cross-section of 158 mm (height) x 79 mm (width) and exit guide cross-section of 149 mm (height) x 85 mm (width) and is of length 816 mm. The vacuum chamber of FGC will be connected to the vacuum chamber of the Background Chopper (BC, disc of outer radius 350 mm). Focusing Guide Section B (FGB) is aligned with FGC and its vacuum shared with the BC vacuum. The FGB has an exit guide cross section of 50 mm (height) x 49 mm (width) and is of length 4046 mm, which will focus the neutron beam vertically and horizontally towards the Al window entrance (0.82 mm thickness, labelled N16) of the Scattering Tank assembly (constructed from 20 mm - 40 mm thickness stainless steel and will be under vacuum < 1 x 10{sup -3} mbar). Inside the Scattering Tank there is another section of Focusing Guide (FGA), with an exit guide cross-section of 30 mm (height) 30 mm (width) and of length 417 mm. The neutron beam exiting the FGA will be reflected by the HOPG crystal pieces of the Graphite Chopper (GC) towards the Backscattering Monochromator (BM). The reflected neutron beam will first pass through the other Al window (0.82 mm thickness, labelled N17) of the Scattering Tank and then enter into a flight tube (steel of 10 mm thickness). The BM is formed in an 1800 mm spherical radius array of Si crystal elements (0.87 mm thickness) and is oscillated by the linear motor Doppler Drive. The neutron beam will be reflected back at 180 deg. from, and focussed by the BM to reenter the Scattering Tank through the N17 Al window. It will then pass through the GC (HOPG crystals are rotated out of the way) and will reach the scattering sample of interest to the instrument end user. Also, inside the Scattering Tank there will be {sup 3}He linear position-sensitive detectors, and Analyser Arrays formed in an 1800 mm radius spherical arrays of Si crystal elements (0.87 mm thickness) glued on aluminium support frames (10 mm thickness) and span ∼160 deg. arc.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗