Search NASA⌕ Search

SEARCH · Search NASA

Results for “Compaction technologies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Towards higher frequencies in a compact prebunched waveguide THz-FEL

Free-electron-lasers fill a critical gap in the space of THz-sources as they can reach high average and peak powers with spectral tunability. Using a waveguide in a THz FEL significantly increases the coupling between the relativistic electrons and electromagnetic field enabling large amounts of radiation to be generated in a single passage of electrons through the undulator. In addition to transversely confining the radiation, the dispersive properties of the waveguide critically affect the velocity and slippage of the radiation pulse which determine the central frequency and bandwidth of the generated radiation. In this paper, we characterize the spectral properties of a compact waveguide THz FEL including simultaneous lasing at two different frequencies and demonstrating tuning of the radiation wavelength in the high frequency branch by varying the beam energy and ensuring that the electrons injected into the undulator are prebunched on the scale of the resonant radiation wavelength.

Experimental particle physics↗

Methodology to Account for Radiation and Temperature Influences on Optical Fibers compaction and Index of Refraction

The effects of radiation induced compaction and index of refraction change can cause significant drift in the measurements from intrinsic fiber optic temperature sensors. The work presented here aims to develop and test a methodology to measure these macroscopic properties that are responsible for the drift in order to correct the measurement. This report discusses the measurement methodology, theory, and sensor construction. Preliminary results from the first irradiation test using this sensor are provided here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method and system for compact efficient laser architecture

A laser amplifier module having an enclosure includes an input window, a mirror optically coupled to the input window and disposed in a first plane, and a first amplifier head disposed along an optical amplification path adjacent a first end of the enclosure. The laser amplifier module also includes a second amplifier head disposed along the optical amplification path adjacent a second end of the enclosure and a cavity mirror disposed along the optical amplification path.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultracompact 3D microfluidics for time-resolved structural biology

To advance microfluidic integration, we present the use of two-photon additive manufacturing to fold 2D channel layouts into compact free-form 3D fluidic circuits with nanometer precision. We demonstrate this technique by tailoring microfluidic nozzles and mixers for time-resolved structural biology at X-ray free-electron lasers (XFELs). We achieve submicron jets with speeds exceeding 160 ms -1 , which allows for the use of megahertz XFEL repetition rates. By integrating an additional orifice, we implement a low consumption flow-focusing nozzle, which is validated by solving a hemoglobin structure. Also, aberration-free in operando X-ray microtomography is introduced to study efficient equivolumetric millisecond mixing in channels with 3D features integrated into the nozzle. Such devices can be printed in minutes by locally adjusting print resolution during fabrication. This technology has the potential to permit ultracompact devices and performance improvements through 3D flow optimization in all fields of microfluidic engineering.

3-D reconstruction↗

Material Control & Accounting Modeling Developments for a Generic TRISO Fuel Fabrication Facility

The Material Protection, Accounting, and Control Technologies (MPACT) program utilizes modeling and simulation to assess Material Control and Accountability (MC&A) concerns for a variety of nuclear facilities. The Sandia National Laboratories (SNL)-developed Fissile Facility Flow Modeler (F3M) and the Material Accountancy Performance Indicator Toolkit (MAPIT) have historically provided MPACT with the capability to analyze MC&A approaches for nuclear facilities to determine that these facilities meet regulatory requirements. In FY25, improvements on the application of the F3M and MAPIT tools to simulate a generic TRi-structural ISOtropic (TRISO) fuel fabrication facility were successfully completed. The generic TRISO fuel fabrication F3M model captures the entire TRISO fuel fabrication process and is adaptable to any final TRISO fuel form, including spherical pebbles and cylindrical compacts loaded into graphite prismatic blocks. Comprehensive F3M/MAPIT functionality for the generic TRISO fuel fabrication model has been demonstrated. This modeling framework can be applied to support the U.S. Department of Energy and domestic nuclear industry stakeholders in developing MC&A approaches for advanced fuel fabrication facilities via statistical tests that demonstrate compliance to regulatory requirements.

97 MATHEMATICS AND COMPUTING↗

Retractable Sensor Poster for ANIMMA 2023 Conference

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-pile environment. The test environment within these reactors are extremely harsh and long-term exposure causes sensor decalibration or failure. Most tests only require data points at daily intervals meaning that the sensor does not necessarily need to be in place continuously for the full experiment. One proposed solution to the issue described above is to have a sensor which can be periodically inserted through a guide tube into the test region and retracted; this would act as a reference check on the sensors installed permanently. If a compact and robust enough design can be made, it has the potential to extend the life of the sensor and keep it within calibration. This LRS entry is for a poster summarizing a presentation that will be given at the ANIMMA 2023 conference. The poster will be on display in the Measurement Sciences Laboratory booth at ANIMMA. Most of the material on this poster came from LRS entry INL/CON-23-72797.

42 ENGINEERING↗

Simulations of three-layer Richtmyer–Meshkov mixing in a shock tube

Here, the Richtmyer–Meshkov instability causes perturbations to grow after a shock traverses a fluid density interface. This increases the mixing rate between fluid from either side of the interface. We use the Flash Eulerian hydrodynamic code to investigate alterations when a thin third layer of intermediate density is placed along the interface, effectively creating two adjacent unstable interfaces. This is a common occurrence in engineering applications where a thin barrier initially separates two materials. We find that the width of the mixing layer is similar or slightly reduced; however, the total mass of mixed material can actually increase. The mixing layer becomes more compact and efficient. However, the normalized mixed mass decreases, meaning that finger entrainment becomes more important than in the simple two-layer case. The effect of adding the central layer appears to decrease when the Atwood number is decreased. The Flash results are also benchmarked against two-layer experimental data from a shock tube at the University of Arizona.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mid-infrared trace detection with parts-per-quadrillion quantitation accuracy: Expanding frontiers of radiocarbon sensing

Detection sensitivity is a critical characteristic to consider during selection of spectroscopic techniques. However, high sensitivity alone is insufficient for spectroscopic measurements in spectrally congested regions. Two-color cavity ringdown spectroscopy (2C-CRDS), based on intra-cavity pump–probe detection, simultaneously achieves high detection sensitivity and selectivity. This combination enables mid-infrared detection of radiocarbon dioxide ( 14 CO 2 ) molecules in room-temperature CO 2 samples, with 1.4 parts-per-quadrillion (ppq, 10 − 15 ) sensitivity (average measurement precision) and 4.6-ppq quantitation accuracy (average calibrated measurement error for 21 samples from four separate trials) demonstrated on samples with 14 C/C up to ∼ 1.5 × natural abundance ( ∼ 1,800 ppq). These highly reproducible measurements, which are the most sensitive and quantitatively accurate in the mid-infrared, are accomplished despite the presence of orders-of-magnitude stronger, one-photon signals from other CO 2 isotopologues. This is a major achievement in laser spectroscopy. A room-temperature-operated, compact, and low-cost 2C-CRDS sensor for 14 CO 2 benefits a wide range of scientific fields that utilize 14 C for dating and isotope tracing, most notably atmospheric 14 CO 2 monitoring to track CO 2 emissions from fossil fuels. The 2C-CRDS technique significantly enhances the general utility of high-resolution mid-infrared detection for analytical measurements and fundamental chemical dynamics studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing low-temperature sintering in the MgO-LiF system: Mechanistic insights

In the present article, we provide compelling evidence that minor (1 wt%) additions of micron and nanometre-sized LiF particles in MgO decompose leading to free Li diffusing into MgO surfaces enhancing vacancy production during direct current sintering. The addition of nanometre-sized LiF particles leads to a > 500 °C reduction in the sintering temperature and over 99 % theoretical density of final consolidated compacts. Correlating differential scanning calorimetry with in-situ x-ray diffraction, together with Schottky calculations, post sintering electron microscopy and laser induced breakdown spectroscopy, we uncover critical insights into this impressive reduction in sintering temperature. Our quantitative analysis reveals that MgO and LiF interact at low temperatures with the diffusion of Li into the surface of MgO particles due to the intrinsic structural disorder of the LiF and MgO crystallites. Nanometre-sized LiF particles were found to react the most at low temperatures due to their increased structural disorder. Our multimodal characterization points to a Li-promoted densification and sintering mechanism. This impressive reduction in sintering temperature can be harnessed to promote low-temperature fabrication of MgO-based composites for technological applications.

36 MATERIALS SCIENCE↗

Performance of Compact Pulsed Thermal Imaging System for In-Service Applications. Pulsed thermal tomography nondestructive examination of additively manufactured reactor materials and components

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of complex topology nuclear reactor parts from high-strength corrosion resistance alloys, such as stainless steel and Inconel. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which has the capability of melting metallic powder and net shaping the structures with relatively high precision. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to creep in high temperature nuclear reactor environment. Currently, there exist limited capabilities to evaluate actual AM structures nondestructively. Pulsed Thermography (PT) imaging provides a capability for non-destructive evaluation (NDE) of sub-surface defects in arbitrary size structures. The PT method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PT method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. The data cube of PT measurements consists of surface temperature taken at sequential time intervals T(x,y,t). Material defects can be detected either by analyzing the thermograms T(x,y,t) data cube, or by using thermal tomography (TT) algorithm to obtain 3D spatial reconstruction of thermal effusivity e(x,y,z). To reduce the cost and enable in-service NDE in spatially constrained environment, it is highly desirable to develop PT with compact and inexpensive IR camera. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact PT system can also be used for in-service nondestructive evaluation (NDE) applications. However, data cube obtained with PT based on compact IR camera suffers from strong thermal noises and loss of features due to relatively low sampling rate. In this report we describe two unsupervised machine learning (ML) algorithms for enhancement of PT images obtained with compact IR camera. In one approach, we introduce Sparse Coding Discrete Cosine Transform (SC/DCT) algorithm to remove additive white Gaussian noise (AWGN) from spatial thermal effusivity reconstructions. In another approach we introduce a Spatial Temporal Denoised Thermal Source Separation (STDTSS) ML algorithm to process thermograms. The STDTSS algorithm consists of spatial and temporal denoising using Gaussian and Savitzky–Golay filtering, followed by the matrix decomposition using Principal Component Analysis (PCA), and Independent Component Analysis (ICA) to automatically detect flaws. In the work described in this report, we constructed a compact PT system using a relatively small and low-cost FLIR A65 camera, consisting on uncooled microbolometer detector. Performance of SC/DCT algorithm was demonstrated on enhancing TT images of Inconel 718 AM plate. Performance of the STDTSS methods was investigated using thermography data obtained from imaging stainless steel 316L specimens produced with LPBF method with imprinted calibrated porosity defects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AN UPDATE ON THE STATUS OF A REDUCED FLOW TEST OF A 10MW 700⁰C SCO2 INTEGRALLY GEARED COMPANDER

In order to maintain viability as a future power-generating technology, concentrating solar power (CSP) must reduce its levelized cost of electricity (LCOE). One component of solving this problem is reducing the cost of the power block while simultaneously increasing the efficiency of the thermodynamic cycle. One disruptive technology that has the promise to accomplish this is supercritical CO2 based power cycles. These cycles are conceptually similar to steam cycles; however, they have substantially smaller turbomachinery at equivalent power while also delivering more efficiency at turbine inlet temperatures of 500-700℃. This paper will summarize the current status of a US Department of Energy project to develop machinery to support a 10 MW sCO2 power cycle. The team of Southwest Research Institute® (SwRI®) and Hanwha Power Systems America, proposed to develop an integrally-geared (IG) compressor-expander (compander) for use in a nominal 10 MW-scale CSP supercritical carbon dioxide (sCO2) plant application. This integrally-geared compander (IGC) comprises multiple pinion shafts interconnected on a single bull gear to create a compact package, and utilizes a low-cost, low-speed driver. In addition, the integrally-geared architecture allows each pinion to operate at different rotational speeds to optimize performance and easily allow for inter-stage cooling and turbine re-heat to further enhance both stage and cycle efficiency. The close integration of all turbomachinery elements into a single integrally-geared (IG) machine creates a design that lends itself to power block modularization, which makes it suitable for waste heat recovery, fossil fuel power plants, and especially CSP applications.

14 SOLAR ENERGY↗

Optimization of neutron chopper and optics for CENTAUR, the SANS/WANS diffractometer at the spallation neutron source second target station

Herein this report presents the physics design and optimization of the neutron chopper and optics systems for the CENTAUR instrument, a multifunctional small-angle and wide-angle neutron scattering diffractometer for the Spallation Neutron Source Second Target Station. This instrument will offer a wide range of capabilities, including small-angle neutron scattering with wide Q coverage (e.g., 0.001–20 Å –1 ), providing a tool to investigate structures from atomic to mesoscopic scales simultaneously. To efficiently transport desired neutrons from the compact high-brightness cold source, several innovative designs are utilized: a time-zero chopper with a straight guide system for short-wavelength neutrons, octagonal guides for higher flux, and a correlation chopper to reduce inelastic scattering. The optimization process considers factors such as useable time-integrated flux, instrument resolution, brilliance transfer, divergence, and acceptance diagram uniformity. The overall design prioritizes flexibility to accommodate diverse user requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Condensation Particle Counter (CPC) Instrument Handbook

The Model 3772 CPC is a compact, rugged, and full-featured instrument that detects airborne particles down to 10 nm in diameter, at an aerosol flow rate of 1.0 lpm, over a concentration range from 0 to 1x104 #/cc. This CPC is ideally suited for applications without high concentration measurements, such as basic aerosol research, filter and air-cleaner testing, particle counter calibrations, environmental monitoring, mobile aerosol studies, particle shedding and component testing, and atmospheric and climate studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acoustic Explosion Data Archive for Machine Learning

The prompt detection of explosions is a key element of the nuclear non-proliferation mission. With traditional sensors being limited in number and scale, smartphones as compact and economical multi-modal sensors are gaining traction and are being deployed. To address the flood of heterogeneous smartphone data, our team proposes a feature extraction using standardized constant-Q frequency bands across acoustic, barometric, and accelerometer data. The work in this presentation contains data collected at Idaho National Laboratory during planned detonations.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Exploration of the parameter space of quasisymmetric stellarator vacuum fields through adjoint optimisation

Optimising stellarators for quasisymmetry leads to strongly reduced collisional transport and energetic particle losses compared with unoptimised configurations. Although stellarators with precise quasisymmetry have been obtained in the past, it remains unclear how broad the parameter space is where good quasisymmetry may be achieved. We study the range of aspect ratios and rotational transform values for which stellarators with excellent quasisymmetry on the boundary can be obtained. A large number of Fourier harmonics is included in the boundary representation, which is made computationally tractable by the use of adjoint methods to enable fast gradient-based optimisation and by the direct optimisation of vacuum magnetic fields, which converge more robustly compared with solutions from magnetohydrostatics. Several novel configurations are presented, including stellarators with record levels of quasisymmetry on a surface, three field period quasiaxisymmetric stellarators with substantial magnetic shear, and compact quasisymmetric stellarators at low aspect ratios similar to tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimizing infrasound observations for sample return capsule re-entry: Insights from OSIRIS-REx and Hayabusa2

The atmospheric entry of meteoroids presents a rare and unpredictable phenomenon, posing challenges for systematic observation and detailed characterization. Such events are nonetheless critical for advancing understanding of acoustic wave propagation, atmospheric structure, and entry dynamics. In contrast, sample return capsules (SRCs) from space missions follow well constrained re-entry trajectories, enabling planned observations of shock wave generation and propagation under controlled conditions. This study compares two SRC atmospheric entries, Hayabusa2 in 2020 and OSIRIS-REx in 2023, to assess how different infrasound array configurations influence shock wave detection and trajectory validation. Hayabusa2’s re-entry was monitored using a distributed network of 28 portable infrasound sensors across seven arrays in Woomera, Australia, permitting three-dimensional reconstruction of the trajectory and analysis of wave characteristics. For OSIRIS-REx, a compact four-sensor array deployed near Eureka Airport provided trajectory confirmation through arrival-time differences and back-azimuth estimates. Spectral and waveform analyses revealed differences in signal properties associated with variations in entry angle and velocity. The results illustrate both the strengths and the limitations of the deployed array configurations. The dense and distributed arrays during Hayabusa2’s re-entry enabled detailed trajectory reconstruction, whereas the compact array at Eureka primarily provided confirmation of signal coherence and back-azimuth consistency. These case studies highlight that even relatively small arrays, if located close to the predicted ground track, can still capture useful information on arrival direction and timing. Such insights provide practical guidance for planning future observational campaigns of SRC returns and other controlled atmospheric entries, and may also inform approaches to opportunistic observations of meteoroid events and other atmospheric acoustic phenomena.

celestial mechanics: orbit determination↗

Quantum algorithm for the linear Vlasov equation with collisions

The Vlasov equation is a nonlinear partial differential equation that provides a first-principles description of the dynamics of plasmas. Its linear limit is routinely used in plasma physics to investigate plasma oscillations and stability. In this paper, we present a quantum algorithm that simulates the linearized Vlasov equation with and without collisions, in the one-dimensional electrostatic limit. Rather than solving this equation in its native spatial and velocity phase space, we adopt an efficient representation in the dual space yielded by a Fourier-Hermite expansion. For a given simulation time, the Fourier-Hermite representation is exponentially more compact, thus yielding a classical algorithm that can match the performance of a previously proposed quantum algorithm for this problem. Further, this representation results in a system of linear ordinary differential equations (ODEs) which can be solved with well-developed quantum algorithms: a Hamiltonian simulation in the collisionless case, and quantum ODE solvers in the collisional case. In particular, we demonstrate that a quadratic speedup in system size is attainable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative SANS and multi-model analysis of spacer-dependent micellization of urea-based gemini surfactants

The micellization behavior of urea-based cationic gemini surfactants was investigated using small-angle neutron scattering (SANS) with multi-model form factor analysis. A homologous series of surfactants with urea group included in the hydrophobic tail and polymethylene spacers consisting of two to ten methylene units was analyzed using three form factor models: a core–shell ellipsoid and two variants of homogeneous ellipsoids. The results from all models show a consistent trend of the micelle structures, confirming that the spacer length critically influences micellar geometry, aggregation number, and hydration. The surfactant with four CH 2 groups in the spacer formed the largest micelles with the highest aggregation number, while longer spacers led to progressively smaller, more compact aggregates. The shell hydration—quantified as the volume fraction of heavy water within the hydrophilic region—decreased systematically with increasing spacer length due to enhanced hydrophobicity of the headgroup-spacer region. Intermicellar interactions, modeled as screened Coulomb interaction using the rescaled mean spherical approximation (RMSA), revealed the strongest electrostatic repulsion for the case of four methylene groups in the spacer, corresponding to the highest micellar charge and largest interparticle spacing. The observed spacer-dependent trends were robust across all modeling approaches, demonstrating that the spacer length serves as a key structural determinant of self-assembly in this type of urea-based gemini systems. These findings provide insight into the design of gemini surfactants with tailored aggregation behavior for applications in drug delivery, nanostructure templating, and solubilization technologies.

Core–shell ellipsoid model↗